Control Box - Boiler Parts - Boilerparts.co.ke

July 19, 2017 | Author: boilerparts | Category: Ignition System, Relay, Combustion, Ultraviolet, Detector (Radio)
Share Embed Donate


Short Description

Control Box parts from the following manufacturer(s): BRAHMA - CSB.240 CEM ECEE - CSB.241 DANFOSS - CSB.243 DUNGS ...

Description

CSB CEM ECEE ................................ CSB.241 DANFOSS.................................. CSB.243 DUNGS ..................................... CSB.244

Control unit

Control unit

BRAHMA ................................. CSB.240

BO

BO

ELESTA ......................................CSB.244 HONEYWELL ..............................CSB.244 LANDIS & GYR - STAEFA SIEMENS ...............................................CSB.247

PACTROL ................................... CSB.252 RIELLO ...................................... CSB.253 RV ............................................ CSB.254

Control and Flame security

LOA 24

SATRONIC..................................CSB.254 SIT .............................................CSB.258 Cell

Insulation transformer .............. CSB.259 Sit control unit Micro ammeter ......................... CSB.259

Microammeter Connector ................................. CSB.259 Ignition spark detector ..............CSB.262

Double connector

Control unit Classification by brand and manufacturer references AT5/TR1

504030

CM11

504036

CSB.240

CM11F

504050

CSB.240

CM191.1

504003

CSB.240

CM191.2/T1.5

504049

CSB.240

CM31

504039

CSB.240

CM31

504040

CSB.240 CSB.240

CM31

40030

CM31

504055

CSB.240

CM31F

504005

CSB.240

CM32

504002

CSB.240

CM32

504037

CSB.240

CM32

504038

CSB.240

CM32

504051

CSB.240 CSB.240

CM32

504052

CM32 PR

504056

CSB.240

CM391.2

504035

CSB.240

CM391.2

504057

CSB.240

CM391.2

504060

CSB.240

CM391.2

40029

CSB.240

DM 32

504054

CSB.240

CSB.240

ER1H

see 402023 504044

CSB.240

G22/03 seule

504019

CSB.240

G22/09 seule

504023

CSB.240

G33/03

504006

CSB.240

GF2/03 seule

504018

CSB.240

GF3/03 seule

504004

CSB.240

M300/02

504027

CSB.240

MF2/02

504033

CSB.240

OF1PR

504058

CSB.240

OR3/B

431131

CSB.240

SM11

504024

CSB.240

SM152.2

504001

CSB.240

SM152.2

504059

CSB.240

SM191.2

504048

CSB.240

SM192.2

504053

CSB.240

SR3/02

504028

CSB.240

SR3/TR

see 504029

CSB.240

SR3/TR01

504029

CSB.240

SR3/TR15

504026

CSB.240

SR3V

504047

CSB.240

TEC3

431260

CSB.240

TM11-37059010 504042

CSB.240

TM31-37065010 504043

CSB.240

VE3-2/05

504025

CSB.240

XM11F

40054

CSB.240

AE25

501900

CSB.242

501615

CSB.242 CSB.242

GA 2510

501620

GB 650

501656

CSB.242

GB 650.1

501622

CSB.242

GE 143

501600

CSB.242

GE 145

501605

CSB.242 CSB.242

GE 236-01

501650

GE 296

501601

CSB.242

GE 633

501630

CSB.242

GE 650

501656

CSB.242

GE 733

501631

CSB.242

GE 735

501632

CSB.242

GU 336-01

501655

CSB.243

MA 152.01

sur devis

CSB.241

MA 23

501360

CSB.241

MA 25

501300

CSB.241

CSB.238

DANFOSS

CSB.240

FR1

GA 2410

CEM ECEE

CSB.240

see 402023

DUNGS

BRAHMA

BO

Control unit

EM41 37201031 402010 ER1

Page

Manufact. Ref.

501300 501310 501320 501100 501370 501010 501350 501380 501385 501010 501009 501375 501374 501376 501373 501379 501377 501378 501020 501020 501330 501340 501040 501050 501060 501391 501391 501391 501392 501391 501020

Ref

CSB.241 CSB.241 CSB.241 CSB.241 CSB.242 CSB.241 CSB.242 CSB.242 CSB.242 CSB.241 CSB.241 CSB.241 CSB.241 CSB.242 CSB.242 CSB.242 CSB.242 CSB.242 CSB.241 CSB.241 CSB.241 CSB.241 CSB.241 CSB.241 CSB.241 CSB.241 CSB.241 CSB.241 CSB.241 CSB.241 CSB.241

see 505156

CSB.243

see 505156

CSB.243

S4561 B 1005 S4561 B 1013 S4561 B 1039 S4562 A 1055 S4562 C 1069 S4562 DM 1006 S4565 A 2019 S4565 A 2027 S4565 A 2035 S4565 A 2050 S4565 A 2068 S4565 A 2076 S4565 AD 2056 S4565 AD 2072 S4565 AD 2080 S4565 AF 1007 S4565 AF 1064 S4565 B 2066 S4565 BD 2021 S4565 BF 1005 S4565 BF 1047 S4565 BF 1054 S4565 BF 1062 S4565 BF 1112 S4565 BF 1161 S4565 BM 1080 S4565 C 1025 S4565 C 1132 S4565 CD 1021 S4565 CD 2029 S4565 CF 1045 S4565 CF 1052 S4565 CF 1060 S4565 D 1007 S4565 DD 1003 S4565 DD 1045 S4565 DF 1050 S4565 DM 1029 S4565 DM 1045 S4565 P 2024 S4565 QM 1012 S4565 RF 1000 S4565 SD 2005 S4565CD2037 S4565D1023 S4570 AS 1012 S4570 BS 1002 S4570 BS 1010 S4570 BS 1028 S4570 BS 1036 S4570 LS 1000 S4570 LS 1026 S4570 LS 1059 S4570 LS 1091 LAE 1/1355 LAL 1.25 LAL 2.14 LAL 2.25 LAL 2.65 LDU 11 523A27 LEC 1/8 853 LFE 10 LFE 50 LFL 1.122 LFL 1.133 LFL 1.148 LFL 1.322 LFL 1.322F LFL 1.333

see 505157

CSB.243

see 505156

CSB.243

505156

CSB.243

505157

CSB.243

505158

CSB.243

505159

CSB.243

507320 509000 509005 509001 509003 509004

CSB.244 CSB.244 CSB.244 CSB.244 CSB.244 CSB.244

407103

CSB.244

508019 508035 508057 508028 508009 508036 508062 508024 508038 508012 508020 508039 508034 508059 508025 508056 508040

CSB.249 CSB.249 CSB.249 CSB.249 CSB.249 CSB.249 CSB.249 CSB.249 CSB.249 CSB.249 CSB.249 CSB.249 CSB.249 CSB.249 CSB.249 CSB.249 CSB.249

HONEYWELL

CSB.240

MA 26 MA 28 MA 29 MA 310-12 MA 41 MA 410-1 MA 43 MA 45 MA 46 MA 510-1 MA 510-1 MA 52 MA 53 MA 55 MA 55D MA 55E MA 55H MA 55R MA 610-1 MA 710 MA 72 MA 73 MA 800 MA 803 MA 810 MA 86-02 MA 86-04 MA 86-05B MA 86-11 MA 87-02 MA 910 BHO 627034/7234 BHO 62D7035/7235 BHO 64.1-7037 BHO 647036/7236 BHO 72.10 57H6102 BHO 72.11 57H6103 BHO 73.10 57H6104 BHO 74.10 57H6105 FFW DGAI 19.2 DGAI 69 VDK200A VPS504 VPS504 W-FM20 V3.02 502 S4560 A 1024 S4560 A 1032 S4560 B 1006 S4560 B 1022 S4560 B 1048 S4560 B 1063 S4560 C 1004 S4560 C 1038 S4560 C 1053 S4560 CB 1022 S4560 D 1077 S4560 D 1135 S4560 D 1143 S4560 D 1150 S4560 M 1036 S4561 A 1007 S4561 A 1015

LANDIS & GYR - STAEFA - SIEMENS

Manufact. Ref.

CSB.240

Ref

HONEYWELL

AT5

CEM ECEE

Page

504031

Manufact. Ref.

Ref 508041 508042 508007 508005 508006 40503 508026 508003 508050 508021 508053 508082 508016 508004 508079 508054 508060 404049 508073 508052 508051 508074 508029 508043 508071 508072 508058 508075 508076 508002 508001 508063 508046 508047 508081 431171 508078 508064 508048 508008 508065 508077 508069 508083 508084 508030 508011 508027 508067 508031 508033 508066 454064 508086 502172 502091 502092 502094 502093 502111 502173 502170 502001 502107 502004 502112 502101 502104 502109

Page CSB.249 CSB.249 CSB.249 CSB.249 CSB.249 CSB.249 CSB.244 CSB.244 CSB.244 CSB.244 CSB.244 CSB.244 CSB.244 CSB.244 CSB.244 CSB.244 CSB.244 CSB.244 CSB.244 CSB.244 CSB.244 CSB.244 CSB.244 CSB.245 CSB.245 CSB.244 CSB.244 CSB.244 CSB.245 CSB.244 CSB.245 CSB.244 CSB.245 CSB.244 CSB.245 CSB.245 CSB.245 CSB.245 CSB.244 CSB.244 CSB.245 CSB.244 CSB.244 CSB.245 CSB.245 CSB.245 CSB.245 CSB.245 CSB.245 CSB.245 CSB.245 CSB.245 CSB.245 CSB.245 CSB.247 CSB.247 CSB.247 CSB.247 CSB.247 CSB.252 CSB.249 CSB.249 CSB.249 CSB.250 CSB.250 CSB.250 CSB.250 CSB.250 CSB.250

Control unit Classification by brand and manufacturer references

420035

CSB.247

424005 424005 432022

CSB.247 CSB.247 CSB.247

407024

CSB.247

407024

CSB.251

407024

CSB.247

502006

CSB.247

502006

CSB.247

424004 502052 502049 502048 see 502383 502056 448065 448066 448050 448064 448062 448063 443010 448014 448010 see 448009 see 448005 448005

CSB.247 CSB.247 CSB.247 CSB.247 CSB.247 CSB.247 CSB.253 CSB.253 CSB.253 CSB.253 CSB.253 CSB.253 CSB.253 CSB.253 CSB.253 CSB.253 CSB.253 CSB.253

448002

CSB.253

448001

CSB.253

MMI 811-35 MMI 812-23 MMI 812-33 MMI 813.1 mod 23 MMI 815 mod 10 MMI 815 mod 5 MMI 962-23

MMO 872

MMO 876

SG 113 SG 513

Page

448007

CSB.253

see 404894 404062 404067 404019 404071 404021 404068 404894 404895 404025

CSB.252 CSB.252 CSB.254 CSB.254 CSB.254 CSB.254 CSB.254 CSB.254 CSB.254 CSB.254

404640

CSB.254

404265 404638 404024 404020 404268 448002 453009 453005

CSB.254 CSB.254 CSB.254 CSB.254 CSB.254 CSB.255 CSB.255 CSB.255

402025

CSB.255

402025

CSB.257

507049 507049 507065 507009 507012 507014 507015 507059

CSB.257 CSB.257 CSB.257 CSB.255 CSB.255 CSB.255 CSB.255 CSB.255

507060

Manufact. Ref. SH 113

CSB.255

507061

CSB.255

507062

CSB.255

Ref

Page

406013

CSB.255

SH 213 mod C1 406019

CSB.256

TF 801

507005

CSB.254

TF 802

507006

CSB.254

TF 804

507007

CSB.255

TF 830

507051

CSB.255

TF 830.3

507064

CSB.255

TF 832

507053

CSB.255

TF 834

see 507001

CSB.255

TF 834.3

507001

CSB.255

TF 834E.3

see 507001

CSB.255

TF 836

507050

CSB.255

TF 840

507054

CSB.255

TF 844

507057

CSB.255

TF 874

405002

CSB.255

TF 974

507016

CSB.255

TFI 812-2 maxi 507043 120 Kw mod 10

CSB.257

TFI 812-2 maxi 350 Kw mod 5

507041

CSB.257

TFI 812-2 mod 10E

replaced by 507049

CSB.257

TMG 740.3 type 32-32 replaces TMG 740.2 type 32-32

507032

CSB.257

TMG 740.3 type 43-35 replaces TMG 740.2 type 45-54

507039

CSB.257

TMO 720-4-35

507020

CSB.255

TTG 760 FN

replaced by 507058

CSB.257

TTG 760 FN

replaced by 507058

CSB.257

TTG 760-33

replaced by 507056

CSB.257

TTG 760-33

replaced by 507056

CSB.257

TTO 810-35

replaced by 507060 + (cell MZ ref 507101 If cell FZ in position or detector IRD1010 following brand or cel UVD ref 507003)

CSB.255

TTO 836-35

replaced by 507062 + (cell MZ ref 507101 If cell FZ in position or detector IRD1010 following brand or cel UVD ref 507003)

CSB.255

TTO 872

replaced by 507060 + (Detector IRD1010 following brand if IRD810 or 910 or 911 in position or cell UVD codes 507003)

CSB.255

TTO 876

replaced by 507062 + (Detector IRD1010 following brand if IRD810 or 910 or 911 in position or cell UVD codes 507003)

CSB.255

507063 (except Guillot) CSB.257 507320

CSB.257

402024

CSB.257

voir 402023

CSB.240

402023

CSB.240

507056 507058 507037 507034 replaced by 507063 (except guillot) replaced by 507033 replaced by 507033

CSB.257 CSB.257 CSB.257 CSB.257

CSB.257 CSB.257

0.503.501

503009

CSB.258

0.503.501

503010

CSB.258

507042

CSB.257

0.503.501

503011

CSB.258

0.537.002 DMT type

404026

CSB.258

0.537.301 DMT type

431015

CSB.258

replaced by 507049 replaced by 507049 507033 replaced by 507060 + (Detector IRD1010 following brand if IRD810 or 910 or 911 in position or cell UVD codes 507003) replaced by 507062 + (Detector IRD1010 following brand if IRD810 or 910 or 911 in position or cell UVD codes 507003) 406009 406020

CSB.257

CSB.257 CSB.257 CSB.257

CSB.255

CSB.255

CSB.257 CSB.257

0.577.009

503002

CSB.258

0.577.211

503005

CSB.258

0.577.304

503007

CSB.258

0.577.308

503003

CSB.258

0.577.311

503004

CSB.258

0.577.503

471003

CSB.258

0.577.504

503001

CSB.258

0.577.701

503013

CSB.258

0.577.702

503012

CSB.258

0.577.705

503006

CSB.258

Control unit

CSB.247

Ref

BO

420035

P16FI (CE)406203 483 SE 503 SE 508 SE 509 SE 520 SE 522 RBO 525 SE 530 SE 531 SE 535 RSE 550SE = 550 SMD 552SE 553SE 555SE MG 569 RMG88.62A2 05125001 Type 05125004 Type 0514 Type Elcopen Analyser defect Elcopen Analyser defect DKG 972 DKG 972 DKG 972 mod 21 DKO 970 DKO 972 DKO 974 DKO 976 DKW 972 DKW 972 + prolong. DKW 976 DKW 976 + prolong. DMG971 FFW 930 FIOUL - GAZ EM41 Kit replacement relay ER1 Kit replacement relay ER1H Kit replacement relay MMG 810-33 MMG 811-63 MMI 810-33 MMI 810-35

SATRONIC

Manufact. Ref.

CSB.250 CSB.250 CSB.250 CSB.250 CSB.250 CSB.250 CSB.250 CSB.250 CSB.250 CSB.250 CSB.250 CSB.250 CSB.250 CSB.250 CSB.250 CSB.250 CSB.251 CSB.250 CSB.250 CSB.250 CSB.250 CSB.251 CSB.251 CSB.251 CSB.251 CSB.251 CSB.251 CSB.251 CSB.251 CSB.251 CSB.251 CSB.251 CSB.251 CSB.247 CSB.247

RV

Ref

RIELLO

Page

502102 502110 502103 502106 502205 502177 502206 502024 502182 502178 502179 502180 502113 502060 502114 502012 502017 502010 502011 502013 502014 502015 502016 502018 502019 502020 502021 502022 502023 see 502012 see 502013 see 502018 see 502019 502385 502383

SATRONIC

LFL 1.335 LFL 1.622 LFL 1.622F LFL 1.635 LGB 21 130A27 LGB 21 330A27 LGB 21 350A27 LGB 21 550A27 LGB 22 230B27 LGB 22 330A27 LGB 41 258A27 LGC 22 002C271 LGK 16.322A27 LGK 16.622A27 LGK 16.635A27 LME 21 230A2 LME 22 232A2 LME 11 330A2 LME 21 120A2 LME 21 33A2 LME 21 35A2 LME 21 55A2 LME 22 131A2 LME 22 233A2 LME 22 331A2 LME 23 331A2 LME 23 351A2 LME 44 056A2 LME 44 057A2 LMG 21 230A27 LMG 21 330B27 LMG 22 233A27 LMG 22 330A27 LMO 24 111A2 LMO 44 255A2 LMO 54 200B2BU LMO 54 200B2BU LMO 54 210B2V LMO 54 210B2V LMO 64 302A2B LMO 82 100C2WH LMO 82 100C2WH LMO 82 100C2WH LMO14 111A2 ou B2 LMO14 111A2 ou B2 LOA 14 171B2V LOA 24 LOA 26 LOA 36 LOA 44 LOK 16 250A27 CSA 12 CSA 6 CSS 01-24R/E CSS01.12 CSS01-12SJV11 CSS01-24JV03 P14 110 AL P16 AFT P16 HIJ 409701 P16B 402701 P16C /FL402801 P16D /402901 P16DI / S (NF) 400601/V03 P16DI /400601

SIT

PACTROL

LANDIS & GYR - STAEFA - SIEMENS

Manufact. Ref.

CSB.239

Control unit GAS type

BRAHMA CONTROL BOX FUEL type

1

2

3

Type

Fuel burners compatible with a fuel flow less than 30 kg/hour. Type Pre Purge Characteristic : 1 firing rate G33/03 15 Characteristic : 1 firing rate G22/03 only one 15 G22/09 only 10 one * Characteristic : 2 firing rates GF2/03 only one 15 GF3/03 only one 20 Characteristic : for FERROLI FR1 10 Characteristic : for BALTUR OR3/B 20 TEC3 10 Characteristic : for ELCO

Control unit

ER1

Safety Time

Detection

Ref

10

Cell

504006

10

Cell

10

Cell

504019 504023

5 5

Cell Cell

504018 504004

10

Cell

504044

5 10

Cell Cell

431131 431260

5

Cell

10

ER1H

15

5

see

402023 see

Cell

402023

** replaces models G22/05, G22/06 and G22/07

NOTE : Application

Ref see

BO

ECOFLAM - FRANCO BELGE - FBR - THERMITAL JOANNES - BALTUR - BIASI - FINTERM - THERMOMATIC - CGA FRANCO BELGE - ECOFLAM - DREIZLER - CHAUFFAGE FRANÇAIS - IDÉAL CLIMA - JUHATHERM - TERMONAFTA MAZECO - SLCF - SANT ANDRÉA - BLOWTHERM - THERMOMEC BALTUR - HS FRANCE- FIM - CTC - THERMOMATIC - RADIANT ECOFLAM - FRANCO BELGE - FONDITAL - PORCHER - CTC - CGA JOANNES - THERMOMEC - FINTERM - THERMOMATIC DREIZLER - JUHATHERM - TERMONAFTA -BLOWTHERM FER-FERROLI BALTUR BALTUR

504006 504019 504023 504018 504044 431131 431260

Pre Purge Safety Time Detection Mark AT5 15" 5" Io 1 AT5/TR1 15" 10" Io 1 CM11 20" 10" Io 2 CM11F 15" 5" Io 2 Characteristic : BPS CM31 30" 10" 2 CM31 30" 5" 2 Characteristic : FRISQUET CM31 15" 5" Io 2 Characteristic : SEET CM31F 10" 5" 1 CM32 30" 15" lo 2 CM32 20" 10" Io 2 Characteristic : SLCF CM32 5" 5" 2 CM32 30" 10" 2 Characteristic : SLCF CM32 2 CM 191.1 Io 1 CM191.2/T1.5 15" 10" Io 1 CM391.2 15" 5" lo 1 CM391.2 * 20" 10" Io 1 Characteristic : GAZ INDUSTRIE gas relay 20s DM 32 M300/02 30" 2" Io/UV 1 MF2/02 30" 2" Io/UV 1 SM11 1.5" 5" Io 2 SM152.2 30" 10" lo 1 Characteristic : EMAT SM191.2 20" 10" Io 1 CM391.2 1 Characteristic : CHAFFOTEAUX SM192.2 1 SR3/TR01 30" 3" Io/UV 1 SR3/02 30" 3" Io 1 Characteristic : SLCF SR3/TR

CELL 2

1 Description FC7/R side shot FC8/R frontal shot TEC3 blue frontal and side shot FC13 red frontal and side shot FC13AL ELCO pluggable

3 Mark

Ref

1 2 3 3 -

504207 504210 431259 431141 402002

BASE

Description G22 - GF2 - G22Z

CSB.240

Ref

504015

30"

3"

SR3/TR15 15" 3" Characteristic : COUSSEMENT SR3V 20" 3" TM1115" 10" 37059010 TM3115" 10" 37065010 VE3-2/05 30" 2" Characteristic : FRISQUET XM11F 15" 5" Characteristic : ELCO EM41 30" 3" 37201031 Characteristic : CHAUFFAGE FRANÇAIS CM391.2 Characteristic : ACCORONI CM31 Characteristic : (CLIMAIR) ROBUR CM32 PR Characteristic : GUILLOT SM152.2 Characteristic : replaces OF1 OF1PR * Hydromotrix

Ref

504031 504030 504036 504050 504039 504040 40030 504005 504002 504037 504038 504051 504052 504003 504049 40029 504035 504054 504027 504033 504024 504001 504048 504057 504053 504029 504028 See

1 1

504029 504026

1 -

504047 504042

Io

1

504043 504025

Io

2

40054

Io

3

402010

Io/UV Io Io Io

-

504060

-

504055

-

504056

-

504059

-

504058

Control unit NOTE : Application

Ref

JOANNES - FINTERM EMAT GEMINOX - PENSOTTI EMAT - BPS - WESPER EMAT- ACCORRONI - NALSON - WESPER EMAT- CHAUFFAGE FRANÇAIS AERMAX- APEN GROUP - GENERFEU - SOLYGAZ - THERMOVUR CHAUFFAGE FRANÇAIS AERMAX ABIG - PENSOTTI - IMMERGAS EMAT - BALTUR FRISQUET - CHAUFFAGE FRANÇAIS EMAT CHAUFFAGE FRANÇAIS CHAUFFAGE FRANÇAIS - ACCORRONI - WESPER JOANNES JOANNES FRISQUET FRANCO BELGE-JOANNES-MAZECO-ECOFLAM - FINTERM CHAUFFAGE FRANÇAIS WESPER-ACCORRONI-EMAT-JOANNES - FINTERM UNIGAS - WESPER - ACCORRONI - BALTUR - ECOFLAM - EMATEUROWARM - FRANCO BELGE - AERMAX - APEN GROUP GENERFEU - SOLYGAS - THERMOVUR - CGA - COLLARD TROLART - PORCHER - LAMBORGHINI - SANT ANDRÉA ECOFLAM-JOANNES-BALTUR - PORCHER - CHAUFFAGE FRANÇAIS

504031 504036 504050 504039 504040 504037 504038 504051 504049 504035 504048 504029 504026 504042 504043 40054 504027 504033 504028 504025

Type

Cell

Pre Purge

Pre Ignition

Characteristic : 220V MA 610-1 8205 10" 10" Characteristic : 220V replaced by MA 610 MA 710 8205 Characteristic : single phase 110/220V MA 800 8205 Characteristic : three phase 220/380V MA 803 8205 Characteristic : single phase 220V MA 810 8205 Characteristic : Replaced by MA610 MA 910 8205 10" 10" Characteristic : MA 152.01 8205 24" 24"

REPLACEMENT INDEX OLD BOX MA 22 MA 25 MA 86-02 MA 87-02

NEW MODEL MA 26 MA 26 MA 86-05 MA 86-05

PostIgnition

Safety Time

Ref

6"

10"

501020

6"

10"

501020

-

10"

501040

-

10"

501050

-

10"

501060

-

10"

501020

18"

5"/8"

on request

Notes BASE without replacement Cell Replaced by 8206 BASE without replacement Cell without replacement

20 type

2

Description UV 1 Ø22 mm FC11 Ø8 mm frontal shot

Mark

Ref

1 2

504218 504215

BASE

Description

504013 504014 504016 504017

CEM ECEE FUEL CONTROL UNIT OLD FUEL MODEL

Pre Ignition Characteristic : 2 firing rates 220V MA 310-1 8205 30" 30" Characteristic : replaced by MA 510-1 MA 410-1 8205 30" 5" Characteristic : 220V MA 510-1 8205 30" 30" Characteristic : 380V MA 510-1 8205 30" 30" Pre Purge

Cell

Pre Purge

Pre Ignition

Characteristic : 2 firing rates MA 23 8208 15" Characteristic : replaced by MA 26 MA 25 8208 15" Characteristic : Cell 8210/8211 MA 26 8206 10" MA 28 8206 MA 29 8206 10"

PostIgnition

Safety Time

Ref

12"

2"

10"

501360

15"

2"

10"

10" 10"

5" -

10" 10" 10"

501300 501310 501320

PROTECTOBLOC type

Pull out equipment. Use with CEM motor and protectobloc transformer Type

Fuel burners compatible with a fuel flow less than 30 kg/hour. Cell

Type

Ref

for MF2 for AT5 / TR-CM391 for AT5 / SR302 / M300 / VE3-2 for SR3 / TR / CM191

Type

Pull out equipment. Use with Fuel-oil burner

BO

1

Control unit

CELL

Cell

Pre Purge

Pre Ignition

PostIgnition

Safety Time

Ref

Characteristic : motor 90W MA 72 8205 5" Characteristic : motor 150W MA 73 8205 5"

5"

-

10"

501330

5"

-

10"

501340

MA 52

2"

2"

10"

501375

-

10"

501374

1"

10" 10“

501391 501391

5/7"

0,5"

10"

501391

MA 86-11 8212 5/7" 5/7" Characteristic : replaced by MA 86-05 MA 87-02 8212 -

0,5"

10"

501392

12"

10"

501391

8209

12/7"

PostIgnition

Safety Time

Ref

20"

5" or 10"

501100

MA 53 8207 10" 10" Characteristic : replaced by MA 86-05 MA 86-02 8212 7" 10" MA 86-04 8212 7" 5"

15"

5" or 10"

501010

MA 86-05B

15"

5" or 10"

501010

15"

5" or 10"

501009

8212

5/7"

CSB.241

Control unit CEM ECEE FUEL CONTROL UNIT 41/43/45/46/ 55 type

Type

Cell

Pre Purge

Pre Ignition

Pull out equipment - Transistor amplifier detects gas flame with a ionization electrode.

PostIgnition

Safety Time

Ref

40" 15"

5" 10"

501370 501350

3" 3"

10" 10"

501380 501385

MA 55 8209 10" 10" 3" 10" Characteristic : Used with preheater MA 55H 8209 10" 10" 3" 10" Characteristic : maintains the tension even if the klixon heater breaks 8207/ MA 55R 10" 10" 3" 10" 8209 Characteristic : ionization MA 55E 10" 10" 3" 10" Characteristic : Remote control 8207/ MA 55D 10" 10" 3" 10" 8209

501376 501377

FEATURES : ✓ Monophased voltage : 220V +10% +15% 50Hz ✓ Contact of flame relay : 220V 2A ✓ Current of flame ensuring a correct operation: between 5 and 120 micro amps ✓ Consumption : 3VA ✓ Ambiant temperature : 50°C maxi ✓ Response time of the flame relay : lower than 0,5 second with the appearance and the extinction of the flame. Description

Ref

501900

AE 25 ionization detector

501378 501379 501373

GA / GB / GE type

CELL

BO

Control unit

Characteristic : 2 firing rates MA 41 8212 15" 15" MA 43 8212 10" 10" Characteristic : Security on stray light MA 45 8212 10" 10" MA 46 8212 10" 10"

CEM ECEE CONTROL UNIT GAS FLAME

1

2

5

3

Type

Pre Purge

Pre Ignition

PostIgnition

Safety Time

Ref

-

5"

501615

-

5"

501620

Characteristic : Blown air burner

4

6

GA 2410

7

Description 8205 for MA 800/72/73/152-01 types (supplied without flange) 8206 use with MA 26/28/29 (side and frontal shots) 8207 use with MA 55R - no flange 8208 use with MA 23 and 25 8209 use with MA 23 / 25 / 52 / 55 8210 use with MA 26/28/29 (side Ø17 shots) 8211 use with MA 26/28/29 (side Ø14 shots) 8212 use with MA 86/ 41/43/45/46 8212 RR same model extended for GIANOLA

Mark

Ref

1 2 3 5 4 2 7 6 6

501220 501260 501261 501290 501500

see 501260

501510 501520 501530

30"

-

Characteristic : atmospheric burner GA 2510

5"/10"

-

Characteristic : Used absolutely with an air pressure switch Relay GB 650 replaces completely GE 650 subject to short circuit of the terminals 12 and 13 which do not exist on the GE 650. GB 650

0"

-

-

4"

501656

-

-

4"

501622

-

-

5"

501600

-

5"

501605

Characteristic : ionization sensor GB 650.1

0"

Characteristic : blown air burner GE 143

20"

Characteristic : atmospheric burner

BASE

GE 145

10"

-

Characteristic : monotube blown air burner GE 236-01

60"

3"

3"

2"

501650

-

-

-

-

501601

-

3"

-

501630

Characteristic : -

1

2

Description S801 for MA 800/803/810 SP06 for MA 152.01 - GE 232/236 S20 for all MA 20 types S401 for MA 40 and 55 types S72 for MA 72 S73 for MA 73 S407 for MA 52 S803 for MA 803 exclusively

CSB.242

3

Mark

1 3 2 2 2 2 1

Ref

501200 501202 501250 501252 501255 501256 501257 501410

GE 296

Characteristic : not recyclic GE 633

3"

Characteristic : can work with shunt on air manostat GE 650

10"

-

-

8"

501656 501631 501632

Characteristic : 2 firing rates GE 733

30"

-

2"

2,5"

GE 735

30"

-

40"

4,5"

Control unit GU (UV) type

BHO 62/64/72/74 type (continuation)

Control and security equipment with flame monitoring by UV sensitive cell. Pre Ignition Characteristic : ignition spark control GU 336-01 60“ Type

Pre Purge

PostSafety Time Ignition 2“

Ref

501655

4“

CELL

1

3

2 Description

Mark

1 2 3

8300 UV Detector 8301 UV Detector industrial model SYLVANIA UV P607.88 - Ø22 mm - 4 pin plugs

Ref

501690 501691 502312

Pre Post- Safety Ignition Ignition Time Characteristic : Landis & Gyr switch position BHO 64 - 7036/7236 13" 13" 15" 10" Characteristic : electronic box with diagnostic blinking light replaces BHO64 BHO 72.10 57H6102 13" 15" 15" 10" Characteristic : electronic box with diagnostic blinking light replaces BHO64.1 BHO 72.11 57H6103 16" 20" 20" 10" Characteristic : electronic box with diagnostic blinking light replaces BHO64A BHO 73.10 57H6104 13" 2" 15" 10" Characteristic : electronic box with diagnostic blinking light equivalent LMO44 BHO 74.10 57H6105 25" 2" 5" 5" Type

Pre Purge

Ref see 505156

505156 505157 505158 505159

Control unit

BASE CELL 2

3

Description SP06 for GE 218/230/232/236/650/GB650/ GU330/336 - MA 152.01 S402 for GE 143 / 145 S412 for GE 733 / 735

Mark

Ref

1 3 2

501202 501204 501205

SPARK DETECTOR Linked to a flame detector circuit that uses ionization electrode, the system detects a flame signaling a spark. It replaces the UV cell for ignition spark detection when the use is compromized. Description DA 51 for GE 633/ 733

Description LD (6 LUX) 057H 7079 - with length 780 mm LD (6 LUX) lg 65,5mm 057H 7079/7279 - with length 780 mm LDS (2 LUX) 057H 7085 - with length 500 mm LDS long 057H 7091 for BENTONE - DEVILLE - HS FRANCE

Ref

505260 505263 505261 505262

BO

1

ADAPTER Ref

501660

SEE THE INSTALLATION DRAFT AT THE END OF THIS CHAPTER Description

DANFOSS CONTROL BOX BHO 62/64/72/74 type

Ref

505411

BHO 70 ADAPTER KIT

BASE

Pre Post- Safety Ignition Ignition Time Characteristic : Landis & Gyr switch position Replaced by 505154 after exhaustion of stocks BHO 62 - 7034/7234 13" 13" 15" 10" Characteristic : Landis & Gyr switch position BHO 64.1 - 7037 6" 6" 20" 10" Characteristic : Danfoss switch position BHO 62D-7035/7235 13" 13" 15" 10" Type

Pre Purge

Ref

Description Base 057H 7010 - 057H 7011 for BHO 61/62/62D/64.1

Ref

505401

see 505156 see 505157 see 505156

FRA / FRU type

Flame control relay used for flame control on semi-automatic installations .

CSB.243

Control unit DANFOSS CONTROL UNIT FFW type for FRA / FRU replacement

HONEYWELL CONTROL BOX S4565 GAS type

Type For fuel or gas, atmospheric or ventilated burner. For semi-automatic installation. ✓ Ionization monitoring or cell UVZ or infrared IRD 1020 detector Description

Ref

507320 507300 805913 708790

FFW FUEL - GAS BASE ZT 870 Transformer AZ5 Pilot burner

Control unit

DUNGS CONTROL BOX DGAI 19 type

DGAI 19.2 control box for atmospheric gas burner, 220VA - 600 Kw, ionization electrode detection. Type

BO

DGAI 19.2 DGAI 69

Pre Purge 4" 50"

Pre PostIgnition Ignition 5" 4" 1" 0"

Safety CharacteTime ristic 13"/8" -

Ref

509000 509005

VDK / VPS / W-F

1

2

3

4 Pre Pre PostPurge Ignition Ignition VDK200A 02 type VPS504 02 type VPS504 04 type W-FM20 V3.02 502 Type

Safety Time 2/5"

Mark

Ref

1 2 3 4

509001 509003 509004 407103

ELESTA CONTROL BOX ACCESSORY Replacement cell

Description 8209 Fuel oil flame control cell /all types of control boxes

CSB.244

Ref

501500

Pre Pre Post- Safety Purge Ignition Ignition Time

Relay used by GEMINOX S4565 A 2027 Relay used by DE DIETRICH - RADIANT S4565 A 2019 Relay used by DE DIETRICH - ZAEGEL HELD- ST ROCH -COUVIN S4565 A 2035 Relay used by CHAFFOTEAUX - ZAEGEL HELD S4565 A 2050 5" Relay used by ACV S4565 A 2068 S4565 AD 2080 Relay used by ROCA S4565 A 2076 Relay used by RIELLO - BERETTA S4565 B 2066 replace S4565 B 2017 Relay used by RIELLO - SIME - CALORTECNICA S4565 CF 1052 Relay used by RIELLO S4565 RF 1000 Relay used by DE DIETRICH - CICH - IDEAL STANDARD - APEN GROUP CALORTECNICA - THERMITAL S4565 C 1025 Relay used by VIESSMANN S4565 C 1132 Relay used by ACTI - SOLARONICS-GUILLOT-GAZ INDUSTRIE S4565 D 1007 Relay used by GEMINOX S4565 AD 2072 S4565 BM 1080 S4565 DM 1045 replaced by S4565 DM 1086 Relay used by RADIANT SPACE RAY S4565 P 2024 Relay used by FERROLI S4565 AD 2056 S4565 CD 2029 10" Relay used by SIME - UNICAL - SAUNIER DUVAL (THELIA 30E) S4565 AF 1007 Relay used by CHAUFFAGE FRANÇAIS S4565 AF 1064 Relay used by FRANCO BELGE S4565 BD 2021 Relay used by DE DIETRICH - IDEAL CLIMA S4565 BF 1005 Relay used by DE DIETRICH S4565 SD 2005 Relay used by SOLARONICS S4565 BF 1047 Relay used by THERMITAL - VIESMANN S4565 BF 1054 Relay used by IDEAL CLIMA- AO SMITH - CHAPPEE -IDEAL STANDARD- THERMITAL S4565 BF 1062

-

-

-

-

Ref

508003 508026 508050 508021 508053 508079 508082 404049 508063 508077 508058 508075 508047 508004 508072 508048 508008 508016 508002 508054 508060 508073 508052 508069 508051 508074 508029

Control unit S4565 GAS (continuation)

S4560/S4561/S4562/S4570 GAS type (continuation) Ref

508043 508071

508081 508064 508001 508046 431171 508065 508084 508083

S4560 / S4561 /S4562 /S4570 GAS type

Type

Pre Purge

Pre Ignition

PostIgnition

Safety Time

Relay used by ACV - INOX G-GE S4560 A 1024 4" 2,5" 5" Relay used by FRANCO BELGE - BONGIOANNI S4560 A 1032 4" 2,5" 10" Relay used by ROCA S4560 B 1006 4" 2,5" 10" Relay used by NESTOR MARTIN - GUILLOT - ATLANTIC S4560 B 1022 4" 2,5" 5" Relay used by BUREX S4560 B 1048 Relay used by SOLARONICS - GUILLOT S4560 B 1063 4" 10" 25" S4560 C 1004 Characteristic : DEVILLE S4560 C 1038 8" 4" -5" Characteristic : UNICAL - ACCORRONI - AO SMITH - ATI BOSCHETTI - ICI S4560 C 1053 24" 4" 10" Characteristic : burner with GEMINOX fan ground boiler w/burner (replaces S4560 D 1028) S4560 D 1077 10" 35" 5" Characteristic : ACTI Characteristic : ACTI - SOLARONICS - INTERCAL S4560 D 1135 24" 4" 25" Characteristic : CHAPPEE S4560 D 1143 16" 4" 25" Characteristic : S4560 D 1150 Characteristic : GEMINOX S4560 M 1036 -

Ref

508019 508035

Pre PostSafety Ignition Ignition Time Characteristic : NESTOR MARTIN S4560 CB 1022 Characteristic : UNICAL - SANT ANDREA - FER - FERROLI S4561 A 1007 Characteristic : FER - FERROLI S4561 A 1015 Characteristic : FER - FERROLI - VAILLANT S4561 B 1013 Characteristic : IDEAL CLIMA - BALTUR S4561 B 1005 Characteristic : CHAUFFE FRANÇAIS - FERROLI S4561 B 1039 Characteristic : FERROLI S4562 A 1055 S4562 C 1069 S4562 DM 1006 Characteristic : AUER S4570 AS 1012 Characteristic : DE DIETRICH S4570 BS 1002 17" 1" 10" S4570 BS 1036 17" 3" 10" S4570 LS 1026 Characteristic : SOLARONICS - GUILLOT S4570 BS 1010 Characteristic : FRANCO BELGE S4570 BS 1028 Characteristic : SOLARONICS - GUILLOT S4570 LS 1000 30" 35" 1" 5" Characteristic : REZNOR-GAZ INDUSTRIE-SOLARONICS S4570 LS 1059 15" 5" Characteristic : SOLARONICS S4570 LS 1091 Type

Pre Purge

Ref

508012 508056 508040 508042 508041 508007 508005 508006 40503 508030

Control unit

508076 508078

508011 508031 508066 508027 508067 508033

BO

Pre Pre Post- Safety Type Purge Ignition Ignition Time Relay used by DE DIETRICH - OERTLI - ROCA S4565 BF 1112 S4565 BF 1161 Relay used by UNICAL S4565 CD 1021 S4565 DF 1050 Relay used by BIASI - MANAUT - RIELLO - ALLIANCE S4565 DD 1003 Relay used by UNICAL - APEN GROUP S4565 DM 1029 Relay used by RIELLO - DOMUS- HERMAN S4565 CF 1045 Relay used by DEVILLE-ZAEGEL HELD- ST ROCH COUVIN S4565 CF 1060 Relay used by BALTUR - HERMANN S4565 DD 1045 10“ Relay used by BERETTA S4565 QM 1012 Relay used by GENERFEU S4565D1023 Relay used by ZAEGEL HELD S4565CD2037

454064 508086

508057 508028 508009

CONTROL and FLAME SECURITY for HONEYWELL INDUSTRIAL BURNERS CELL

508036 508062

1

508024 508038 508020 508039 508034 508059 508025

2

3

Description Mark UV Cell C7027A1049 Monoblock tube frontal shot IP677 Fixing 1/2“ NPT - Cable 2,4m - Temperature 1 -18 to +102°C UV Cell C7027A1056 Monoblock tube frontal shot IP677 Fixing 1/2“ NPT - Cable 2,4m - Temperature 1 -18 to +102°C UV Cell C7027A1064 Monoblock tube frontal shot IP677 Fixing 1/2“ NPT - Cable 7m - Temperature 1 -18 to +102°C UV Cell C7027A1023 Monoblock tube frontal shot IP677 Fixing 1“ NPT - Cable 1,8m - Temperature 2 -18 to +121°C UV Cell C7061A1020-ST001 IP677 - Temperature 3 -40 to +80°C with amplifier lens

Ref

508202 508203 508204 508205 508206

CSB.245

Control unit CONTROL and FLAME SECURITY for HONEYWELL INDUSTRIAL BURNERS PROGRAMMER

RELAY

Primary relay with reversing switch Universal programmer pluggable to Q 7800 base APAVE D 15/97 -43.2 approved Description EC7850A1072 - 230Vac - post purge : 2s

Ref

508227

Description R4343D1041-ST005 Standard amplifier incorporated - Ionization 115/230Vac - 2 reversing switches : 4A cos ϕ 6,35 R4343E1048-ST005 UV standard amplifier incorporated for mini Cell C7027 or C7035 - 115/230Vac - 2 reversing switches : 4A cos ϕ 6,35

Ref

508209 508210

BASE Half automatical industrial relays Universal relay- 115/230VAC Start auto control for pluggable amplifier R72xx 2 independant relays For 7800 type Description Q7800A1005 plastic version

Ref

508208

Control unit

PRE-VENTILATION CARD

Ref

508212 508211

BASE Range of purge timer Description ST7800A1039 - 30s

Description

Ref

508224 508225

ST7800A1013 - 7s

BO

Description R4348B1057 Output and LED meter contact rating 4-20MA Gives an indication of flame current strength (onlynfor measure not for security) IP54 APAVE D 15/95 -40.1 approved R4348B1008 Standard model - without flame current jack socket - IP54

Ref

508200

Base box R4348

AMPLIFIER

AMPLIFIER 1

2

For UV : R7824/47/49/61/86 - Pluggable - additional modules For UV : R7824/47/49/61/86 - Pluggable - additional modules Description R7849A1023 standard - 2s - for C7027/35/44 detector R7861A1026 Auto-verifying - 2s - for C7061 detector APAVE D 15/97 -43.2 approved

Ref

508219 508220

Description R7323B1026 standard (U.V.) - 2s - for detector C7027/35/44 R7323B1018 standard (U.V.) - 2s R7061A1016 Auto-verifying (U.V.) - 2s - for detector C7061 APAVE D 15/86 -10.3 approved R7247A1005 Auto-verifying (U.V.) - 2s - for detector C7012E APAVE D 15/95 -40.1 approved

Mark

Ref

1

508216

1

508215

2

508213

2

508214

SEAL CONTROL PROGRAMMER For flame electrode : R7847A/B - Pluggable - additional modules Description R7847A1033 standard - 2s - for C7012A/G detector R7847B1031 Auto-verifying - 2s - electrodes detector APAVE D 15/97 -43.2 approved

Ref

508217 508218

S7820A1007 only remote reset

CSB.246

Description

Ref

508201

A4021A1002 230 Vac

MANUAL REMOTE RESET MODULE

Description

Air pressure control LED display

BASE

Ref

508222

Description ZL030001 Seal control base

Ref

508226

Control unit ADAPTER

LAL ... /LOK type

Adapter 4-20mA for M9184 (internal connection) Description

Ref

508207

Q7230A005 4 - 20mA

Pre PostIgnition Ignition Characteristic : 3 stages remote lockout + Switch for airdamper QRB1 Type

Pre Purge

LAL 1.25

22.5"

Safety Time

Ref

5"

502091

5"

502092 502093

27.5"/2.5" 22,5"/5"

Characteristic : 3 stages remote lockout + Switch for airdamper RAR or QRB1

LANDIS & GYR STAEFA - SIEMENS FUEL CONTROL BOX LOA type

LAL 2.14

14"

LAL 2.65

67.5"

14"/2"

10"/4"

27.5"/2.5" 22.5"/5"

5"

Characteristic : photo resistant or electric cell + air pressure + QRB1 LAL 2.25

27.5"

27.5"/2.5" 22,5"/5"

5"

502094

5"

502056

Characteristic : Detection by RAR 7 or RAR 6 LOK 16 250A27

Safety Time

Ref

ADDITIONAL TECHNICAL OVERVIEW IMPORTANT : For telegestion, replace LAL by LOK 16. In that case move the polarization pins.

Characteristic : Special VIESSMANN LOA 14 171B2V

-

-

-

-

424004

10"

502052

Characteristic : alternative for LOA 22 + decrease voltage security LOA 24

13"

13"

0/13"

Characteristic : Will replace LOA 24 when no more available. LMO 24 111A2 (1)(2)

16"

15"

10"

10"

502385

Characteristic : Special CHAPPEE - IDEAL STANDARD LMO14 111A2 ou B2 (1)(2)

16"

10"

10"

502006

-

-

3s gas 5s fuel

407024

-

-

7s

420035

-

-

424005

15"

10"

502049

5/8"

5"

see 502383

15"

Characteristic : Special WEISHAUPT LMO 82 100C2WH (1)(2)

-

Characteristic : Special BUDERUS LMO 54 200B2BU (1)(2)

-

Characteristic : Special VIESSMANN LMO 54 210B2V (1)(2)

-

-

Characteristic : decrease voltage protection LOA 26

13"

13"

Characteristic : 2 firing rates + 30 kg/h LOA 44

25"

25“

Characteristic : Will replace LOA 24 when no more available. LMO 44 255A2 (1)(2)

26"

25"

5"

5"

502383

-

-

432022

15"

10"

502048

Characteristic : Special BENTONE LMO 64 302A2B (1)(2)

-

-

Characteristic : voltage light - flame light LOA 36

13"

13"

(1) Automatic failure detection box. 3 blinking different colors signal a defect. (2) Use with QRB1 or QRC1. No needs to replace the base.

15"

LAL

Box type Intermittent functioning Permanent functioning Voltage 230V Box model M Contact MO = motor (synchrone) Programmable starter Decrease voltage Protection Remote control release Cell QRB Cell QRB Cell RAR Contact 2 Ev Contact air flap Temperature adjustment or boiler pressure

Control unit

Pre Purge

PostIgnition

27.5"/2.5"

LOK 16 250A27

1.25 X X X

2.14 X X X

2.25 X X X

2.65 X X X

X

X

X

X

X

X X X X X X X

X X X X X X X X

X X X X X X X X

X X X X X X X X

X X X X X X

X

X

X

X

X

X X X

BO

Type

Pre Ignition

27.5"

LAE type NOTE : Adjustable preventilation from 8" to 63". Total preventilation and post ventilation cannot exceed 90" (when Pre-purge = 8", post-purge = 82" etc...) Adjustable security delay from 0“ to 9" Type LAE 1/1355

Pre Purge

Pre Ignition

PostIgnition

Safety Time

Ref

30"

3"

-:

5"

502172

FLAME DETECTOR Yellow flame detector box for fuel oil burner flame control. Use with cell RAR7 and RAR8. Use with program LEC1.

Description LAE 10

Ref

502171

CSB.247

Control unit BASE

LANDIS & GYR STAEFA - SIEMENS FUEL CONTROL BOX Cell 4

3

2

1

1

2 Description

Description QRB1A with cable L800mm for WEISHAUPT lg 65mm QRB1A with AMP II n°9 for WEISHAUPT lg 65mm QRB1B with AMP III for CHAPPEE - IS - BAXI Cell lg 50mm- lg 190mm QRB1A with AMP III n°13 for WEISHAUPT lg 65mm QRB1A for LAI - LAB- LAC - LOA - and LAL1 Ø9 mm QRB1A A068B70B QRB1B A048B70B QRB1B A068B70B QRB1B D022X20B QRB1B D025B40B

AGK11 for LOA - LGA - LMO AGK85.22A27 for WEISHAUPT AGM410.490500 for LAL AGM16 for LOK16

Mark

Ref

2 2 1 -

502352 502355 502367 502354

Mark

Ref

1 2

407137 407144

2

401061

ADAPTER KF type

3 4 4 4 4 4 4

407143 502221 502025 502026 502027 502029 502031

Allows the replacement of old control boxes without re-wiring LAI - LAB LAC LFA - LFB - LFi - LFM

Control unit

Description

5

6 8

7 9

Description QRB1B A148B70B

BO

QRB1B high sensibility QRB1B wire 1,50 m QRC1 UV sensitive. Use with boxes ref: LOA & LMO (except LOA 25 & LOA 28) QRB1B specific CUENOD and ELCO QRB1B 4MST with AMP II for KORTING QRC1.A1.170C27A

10

Mark

Ref

5 6

502226 502222 502224

7

502235

8 9 7

502223 502225 502234

13

12

11 Description

QRB1B C036B40A QRB1B 4MST with AMP II for WEISHAUPT Lg 56 mm QRB1B with AMP III n°13 for WEISHAUPT Lg 65 mm QRB3 for LAI - LAB - LAL1 - LOA - LAC - LAE RAR7 selenium cell replaces RAR2 RAR8 selenium cell replaces RAR3 RAR9 Cell

Mark

Ref

13 10 10 11 12 12 12

502028 407011 407043 502230 see 502261 see 502261

502261

BASE

IMPORTANT : Fix these adapters between the new box and the old box base

CONTROL BOX TESTER LANDIS & GYR - STAEFA - SIEMENS

KF 8840 type

The fixed adapter, located between the base and the box, indicates the activation program, and at the same time measures the voltage control through the pin plugs. There are 2 measuring sockets to control the flame signal and one simulation selector Description

Description AGK 86.10A27 for Weishaupt WG30 AGK4 104.13450 for LAE 10 - LAI - LAB - LF1 - LFM height 20 mm AGK4 104.90250 for LAI - LAB - LF1 - LFM height 27 mm

CSB.248

502199

LAI / LAB / RBQ REPLACEMENT INDEX

The adapters are necessary when out- of -production security boxes need to be replaced. The new KITS, are easy to fix and avoid the replacement of the base ; they are designed to keep the same height position. When a replacement is needed, a wiring modification may be necessary : the instructions are then provided. OLD RELAY

2 Mark

Ref

2

407086

1

502350

1

502351

Ref

KF 8840 TESTER

Type

1

Ref

502370 407300 502378 502360 502381

KF 8819 in replacement of LAI et LAB by LOA KF 8826 in replacement of LAL 12.1 by LOA 24 (MONARCH) QRB1 KF 8852 in replacement of LFI 7 by LGB KF 8880 in replacement of LFM by LGB2 (burner with fan) KF 8862 in replacement of LFM by LB41 (atmospheric burner)

ADAPTATION KIT New Relay Primary all Adapter

LAI 1/2/4 - LAB LOA 24 16.3 type 01 LAI 12 type 01 LOA 24 LAI 12.1 LOA 24 LAB 1 LOA 44 LAB 15 / 15.1 LOA 44 LAB 16.3 type 3 LOA 44 RBQ 31 / 34 LAL 1.25 RBQ 33 LAL 1.25

Cell with none

Ref

QRB1/3

KF 8819

-

X

502062

QRB1/3 QRB1/3 QRB1/3 QRB1/3 QRB1/3 QRB3 QRB3

KF 8826 KF 8826 KF 8819 KF 8819 KF 8819 re-wire re-wire

-

X X X X X -

502063 502063 502063 -

-

Control unit LAI / LAB by LOA type REPLACEMENT KIT

LANDIS & GYR STAEFA - SIEMENS MIXED CONTROL BOX MIXED LEC type

LOA 21 & LOA 22 , have been stopped in january. 1997. Those are replaced by ref: LOA 24 ,CE conform. KIT Composition

Ref

KIT LAI

LAI 1 / LAI2 / LAI 2.2/ LAI 4 /LAB 16.3 type 01

LOA 24 + KF 8819 no cell replacement

502062

KIT LAB

LAB 1/ LAB15 /15.1 LAB 16.3 type 03

LOA 44 + KF 8819 no cell replacement

502063

LANDIS & GYR STAEFA - SIEMENS FUEL CONTROL BOX LAC 1/2/3 REPLACEMENT INDEX

The adapters are necessary when out-of-production security boxes need to be replaced. The new KITS, are easy to fix and avoid the replacement of the base ; they are designed to keep the same height position. When a replacement is needed, a wiring modification may be necessary : the instructions are then provided. Old box

ADAPTATION KIT Replaced by Primary all

Adapter Characteristic : LAC 1.013 LAL 2.14 QRB1 LAC 1.025 LAL 1.25 QRB1 LAC 1.035 LAL 1.25 QRB1 Characteristic : QRB1 & QRB3 are used according to burner type. LAC 1.125 LAL 2.65 QRB1/3 LAC 2.013 LAL 2.14 QRB1 LAC 2.025 LAL 1.25 QRB1 LAC 2.035 LAL 1.25 QRB1 Characteristic : QRB1 & QRB3 are used according to burner type. LAC 2.125 LAL 2.65 QRB1/3 KF 8808 Characteristic : LAC 3.013 LAL 2.14 QRB1 KF 8810 Characteristic : If there is any control connection to screw 8 or 14, replace the LAC3 with a LAL 2.25 type. LAC 3.025 LAL 1.25 QRB1 KF 8810 Characteristic : If there is any control connection to screw 8 or 14, replace the LAC3 with a LAL 2.25 type. LAC 3.035 LAL 1.25 QRB1 KF 8810 Characteristic : QRB1 & QRB3 are used according to burner type. LAC 3.125 LAL 2.65 QRB1/3 KF 8808

RAQ / RAI / LAB10 REPLACEMENT INDEX OUT OF PRODUCTION boxes. Base re-wiring and a new cell are necessary Old box

Replaced by

Scheduler for double monitoring with detector LAE 10 or LFE 10. NOTE : Adjustable preventilation from 8“ to 63“. Total Preventilation time + post-ventilation can not exceed 90“ (when Preventilation = 8“, post-ventilation = 82“ etc...) Type

PrePurge

PreIgnition

LEC 1/8 853

30"

3"

PostSafety Time Ignition -

Ref

502173

5"

MIXED LFE10 type

Control unit

for Replacement

Blue flame detector used for fuel or gas. Link with LEC program. Description

Ref

502170

LFE 10

BASE

BO

Description

2

1 Description

Mark

Ref

1 2

502364 502350

AGG4 104.1713 (AE) AGK4 104.13450 for LFE 10

RWA REPLACEMENT INDEX Old box RWA2

Replaced by

Cell

LEC1

NONE

LANDIS & GYR STAEFA - SIEMENS GAS CONTROL BOX LFE type

Cell

RAQ 15.1

LAE 1/1 355

RAR 7/8/9

RAQ 15.2

LAE 1/1 355

RAR 7/8/9

RAQ 15.3

LAE 1/1 355

RAR 7/8/9

RAQ 10.1/2

LAE 10

RAR 7/8/9

RAI 20

LAE 10

RAR 7/8/9

RAI 15.1

LAE 1/1 355

RAR 7/8/9

RAI 15.3d

LAE 1/1 355

RAR 7/8/9

RAQ 15.4d

LAE 1/1 355

RAR 7/8/9

LAB 10

LAE 10

RAR 7/8/9

Type LFE 50 *

PrePurge -

PrePost Ignition Ignition -

-

Safety Time

Ref

-

502001

NOTE : * Control box of flame that works with a LEC1 relay. The direction is done with a QRA50M (frontal shot) or QRA51M (side shot)

CSB.249

Control unit LANDIS & GYR STAEFA - SIEMENS GAS CONTROL BOX LFI 7 / LFM 1 type

LGB 21 / 22 / 41 type (continuation) Type

LFI relay provides automatic activation and monitoring of blown air gas burner (monotube 1 firing rate). LFM relay is used for automatic control and activation of gas burner (with 1 or 2 stages; with or without a fan). PrePreType Purge Ignition Characteristic : instant steam generator LFI 7-13 8" 0,5" Characteristic : LFI 7-33 30" 0,5" Characteristic : atmospheric burner LFI 7-35 30" 0,5" Characteristic : ignition spark control LFM 1-33F 30" 0,5" Characteristic : atmospheric burner LFM 1-35 30" 0,5"

Post Ignition

Safety Time

3"

3"

3"

3"

5"

5"

3"

3"

5"

5"

Ref

see replacement index page CSB.252

Control unit

Pre Ignition

PostIgnition

Characteristic : LGB 21 550A27 Characteristic : 2 firing progressive rates LGB 22 330A27 30" 3" 2,4" Characteristic : BENTONE LGB 22 230B27 Characteristic : 2 firing rates /atmospheric burner LGB 41 258A27 18" 2" 4"

Safety Time

Ref

-

502024

3"

502178

-

502182

5"

502179

NOTE : For the startup with ignition spark control use QRE1 for LGB 21/22 and 41.

LGC 22 type

Pre PostIgnition Ignition Characteristic : Box for wall unit gas boiler specific to BROTJE (270961) LGC 22 002C271 1,5" Type

LFL type

BO

Pre Purge

Pre Purge

Safety Time

Ref

10"

502180

LGK type Flame control by UV or ionization Type

Pre Purge

Pre Ignition

PostIgnition

Safety Time

Characteristic : steam generator LFL 1.122 14" 4" 2" 2" Characteristic : LFL 1.133 14" 4" 3" 3" Characteristic : 2 ionization sensors possible LFL 1.148 14" 2" 4" 4" Characteristic : burner 1 or 2 tubes 3 firing rates remote control release + air damper ionization or UV LFL 1.322 37,5" 4"/2" 2"/4" 2"/4" LFL 1.335 37,5" 5"/2,5" 2,5"/5" 2,5"/5" Characteristic : burner 1 or 2 tubes 3 firing rates remote control release + air damper ionization or UV LFL 1.622 66" 4"/2" 2"/4" 2"/4" LFL 1.333 32" 6" 3" 3" With spark detection by QRE1. Control by ionization or UV. Characteristic : burner 1 or 2 tubes 3 firing rates remote control release+ air damper ionization or UV monitoring LFL 1.622F 66" 4"/2" 2"/4" 2"/4" Characteristic : LFL 1.322F 37,5" 4"/2" 2"/4" 2"/4" Characteristic : gas and mixed LFL 1.635 67,5" 5"/2,5" 2,5" 2,5"

Ref

502107 502004 502112 502101 502102 502110 502109

502104 502106 Can replace LGB and LMG boxes and detect any defect (blinking reset button) When operating with UV sensor, you must use a control module (AGQ3 Ref 502323)

PostIgnition

Safety Time

Ref

Characteristic : steam generator 2 firing rates LGB 21 130A27

7"

2"

2,4"

3"

502205 502177 502206

Characteristic : 2 firing rates LGB 21 330A27

30"

2"

2,4"

3"

LGB 21 350A27

30"

2"

4"

5"

CSB.250

Ref

502060 502113 502114

502103

Box for small or medium power gas burners, with or without a fan. Flame monitoring by ionization sensor or UV sensor. Lower voltage Security . Remote control release . Air pressure control when startup. When operating without any motor, it is necessary to cable on plug 3 a resistance type AGK 2500 A 27 (except for LGB41) When a LFI is replaced you must adapt the monitoring module UV A6Q2.1A27 ref 502321. Type

Description LGK 16.622A27 LGK 16.322A27 LGK 16.635A27

LME type

LGB 21 / 22 / 41 type

Pre Pre Purge Ignition

LGK 16.622A27 self-controled detection circuit, linked to a ionization sensor or UV cell like QRA 53/55 ; same program as LFL boxes NOTE : LGK 16 Necessary for self or remote heating plant. It replaces the LFL relay.

Pre PostSafety Ignition Ignition Time Characteristic : defect box detection LME 11 330A2 30" 2" 3" Characteristic : defect box detection replaces LGB 21.130A27 and LMG 21.130B27 LME 21 120A2 7" 2" 3" Characteristic : defect box detection replaces LGB 21.230A27 and LMG 21.230B27 LME 21 230A2 20" 3" 3" Characteristic : defect box detection replaces LGB 21.330A27 and LMG 21.330B27 LME 21 33A2 30" 2" 3" Characteristic : defect box detection LGB 21.350A27 et LMG21.350B27 LME 21 35A2 30" 2" 5" Type

Pre Purge

Ref

502010 502011 502012 502013 502014

Control unit LME type (continuation)

LAMP / REPLACEMENT BULB

Pre PostSafety Ignition Ignition Time Characteristic : defect box detection replaces LGB 21.550A27 and LMG 21.550B27 Type

Pre Purge

LME 21 55A2

50"

2"

-

Ref

LME 22 131A2

50"

3"

-

502016

3"

20"

3"

-

Ref

502313 502314

UV LAMP standard for QRA ref AGR 45 02 11310

Characteristic : defect box detection replaces LGB 22.230A27 and LMG 22.230B27 LME 22 232A2

Description

502015

5"

Characteristic : defect box detection replaces LGB 22.130A27 and LMG 22.130B27

UV LAMP high sensitivity ref AGR 45 02 0650M

BASE 502017

3"

Characteristic : defect box detection replaces LMG 22.330B27 LME 22 233A2

20"

3"

-

502018

3"

1

Characteristic : defect box detection replaces LGB 22.330A27 LME 22 331A2

30"

3"

-

502019

3"

Characteristic : defect box detection replaces LGB 32.330A27 LME 23 331A2

30"

1"

-

502020

5"

Characteristic : defect box detection replaces LGB 32.350A27 LME 23 351A2

30"

1"

-

502021

5"

Characteristic : defect box detection replaces LGB 41.255A27 LME 44 056A2

9"

2"

-

502022

5"

2 Description

AGG4 104.1713 (LFE1) AGK11 for LOA - LGA - LMO AGK 4101 13450 for LFI - LFE10 - LFM - LAE 10 AGK 4101 90250 same base for these different models height 27 mm instead of 20 mm LGK16 BASE AGM17 LFL BASE 4104 0550 AGK85.22A27 for Weishaupt

LME 44 057A2

9"

2"

-

502023

5"

Mark

Ref

1 2 3 -

502362 502352 502350 502351 502356 502366 502355

Control unit

Characteristic : defect box detection replaces LGB 41.258A27

3

KF ADAPTER

(the detection and defect analysis). It uses reset switches that blink. example : ➦ flame detection defect - 2 blinks ➦ pressure air defect - 3 blinks The analysis is stored even when device is off. When operating without any motor, it is necessary to cable on plug 3 a resistance type AGK 2500 A 27 (except for LGB41) when a LFI is replaced you must adapt the monitoring module UV A6Q2.1A27 ref 502321. PrePurge

Type

PreIgnition

PostIgnition

Safety Time

Ref

-

3" 3" 3" 3"

See 502012 See 502019 See 502019 See 502018

Characteristic : defect box detection LMG 21 230A27 LMG 21 330B27 LMG 22 330A27 LMG 22 233A27

20" 30" 30" 20"

2" 2" 3" 3"

Characteristic : Limp mixed gas and fuel for Weishaupt LMO 82 100C2WH

-

-

-

407024

3"

Cell

Description KF 8852 in replacement of LFI 7 by LGB KF 8853K in replacement of LFI 7 by LGB22 KF 8880 in replacement of LFM by LGB 2 KF 8862 in replacement of LFM by LGB 41

Ref

502378 502361 502360 502381

BO

LMG/ LMO type These control boxes can replace the LGB types

SPARK DETECTOR

QRE 1 spark ignition electronical detector. Used on burner controlled by ionization whose light flow is higher than 15% of the nominal capacity Description QRE 1 QRE1 150

see

Ref 502032

502032

RC CIRCUIT 1

2

4

3

Description

Essential when LFI / LFM et LGA- LGB LMG are connected to 220V mono electric supply (between 2 phases). Description

Mark

Ref

QRA 2 UV detection cell for gas or mixed burner RED SPOT QRA 2M UV detection cell, same application, high sensitivity GREEN SPOT

2

502310

-

502311

QRA 10C

1 3 4

502308 502309 502320 502002 502003

UV Cell

QRA 10MC UV high sensitivity cell QRA 55

UV Cell of 70 mm for LGK 16

QRA 50M

UV Cell

QRA 51M

UV Cell

Ref

502316

RC circuit

UV MONITORING MODULE AGQ1.1A27 for relay type LGB... LMG Additional module for gas burner flame monitoring with UV sensor type QRA... Under base assembly. Description AGQ1.1A27 for relay type LGB... LMG AGQ3.1A27 for relay type LME

Ref

502321 502323

CSB.251

Control unit LANDIS & GYR STAEFA - SIEMENS GAS CONTROL BOX LFG / LFI / LFM REPLACEMENT INDEX Not necessary to rewire, when replacing Type Characteristic : -

Replaced by

Primary cell Adapter

RAI / RAQ REPLACEMENT INDEX OUT OF PRODUCTION boxes. Base re-wiring and a new cell are necessary, when you take a new box. none

LGB21 330A27or 502177 or 502350 LMG21 330A27 502007 LFI 713 LGB 21 130A27 Io KF8852 LGB 21 330A27 or LFI 733 Io KF8852 LMG 21 330A27 LFI 735 LGB 21 330A27 Io KF8852 Characteristic : Check that terminal 4 stays connected to the old base For UV type, add module AGQ ref Diff 502321 LFM 1.33 KF8880 LGB 21 330A27 or LFM 1.33F Io/UV except LMG 21 330A27 LFM1.35 CUENOD

LFG 1.33

X X X

OLD BOX RAI 15.2 RAI 15.1 RAI 15.3d RAQ 10.1 RAI 20

Replaced by LFE 1/8 853 LFE LFE LFE 10 LFE 10

Cell Io Io or QRA2 Io or QRA2 Io Io or QRA

X

LDU type CONTROL BOX

X

LGB 21 350A27 or LGB 22 330A27 or Io/UV KF8880 X LMG22 330A27 Characteristic : Check that terminal 4 stays connected to the old base. Replacements for atmospheric burners LFM 1.33 LFM 1.33F LGB 41 258A27 Io KF8862 X LFM1.35 LFM 1.35

The Leak detector LDU11 is designed for double shuttingsgas installations . After each activation cycle, the box programs automatically the seal control, and prevents the burner to start in case of internal leakage

LFC / LFI REPLACEMENT INDEX OLD BOX

BO

Control unit

Type

Replaced by

ADAPTATION KIT Primary Adapter cell

Characteristic : LFC 1.1 LGA 41 173A 27 Sensor Io LFI 5.19 type 02 LGA 41 173A 27 Sensor Io Characteristic : without ventilator 1 firing rate LFI 1 série 02 LGA 41 173A 27 Sensor Io Characteristic : without ventilator 2 firing rates LFI 1 série 02 LGA 52 150A 27 Sensor Io

Cell with none

-

-

X X

-

-

X

-

-

X

Description

Ref

502111

LDU 11 523A27 type 220 volts

PACTROL CONTROL BOX P14 type

LFA / LFB / REPLACEMENT INDEX OLD BOX

ADAPTATION KIT Cell Primary Type Replaced by Adapter cell with none Characteristic : when ignition spark detected, use boxes type F+QRE Ref 502315 LFL 1.122 LFA 2.12 Io X type 02 Characteristic : (1) when ignition spark detected, use boxes type F+QRE Ref 502315 (2) LFA ionization flame monitoring (3) LFB UV flame monitoring LFA (2) or LFB (3) 1.32/ 1.322 (1) LFL 1.322 X Io or UV 2.32 /2.322 (1) type 02 4.32/ 4.322 (1) X LFA (2) or LFB (3) X 1.33/ 1.355 LFL 1.335 2.33/ 2.355 Io or UV type 01 4.33/ 4.355 (1) LFA (2) or LFB 1.62/ 1.622 2.62/ 2.622 4.62/ 4.622 LFA (2) or LFB 1.63/ 1.635 2.63/ 2.695

(3) (1) LFL 1.622 (1) type 02 (1) (3) LFL 1.635 type 01

Io or UV

Io or UV

Replaced by

Ref

Characteristic : (1) use these models for atmospheric burners LFD 1.33 LFL 1.335 or 502102 or type 02 LGB 41 (1) 502179 (1) LFL 1.335 or 502102 ru LFD 2.35 LGB 41 (1) 502179 (1) LFL 1.335 or 502102 or LFD 2.38 LGB 41 (1) 502179 (1)

CSB.252

Range of Control boxes, completely automatic, for atmospheric or air (forced up to 60 kw) burners. The case includes an ignition generator and a single or double electrode . The range of PACTROL P16 controls alternatively the ignition and the flame for burners up to 60 Kw (forced air) or above. Supplied without base.

-

X

Type

-

-

X

Characteristic : 1 firing rate

-

-

X

Base for re-wiring ref 502366 or 502350 502366 or 502350 502366 or 502350

Cell

none none none

Ref

443010

P16 type

-

LFD REPLACEMENT INDEX Type

Description P14 110 AL for radiant gas (selfcontrol gas)

P16C /FL402801

Pre Pre Post- Safety Purge Ignition Ignition Time -

6"-12"

-

5"

Ref

see

448005

Characteristic : 2 firing rates P16D /402901

-

6"-12"

-

5"-10"

P16DI /400601

-

6"-12"

-

5"-10"

448005 448001

P16DI / S (NF)400601/ V03

-

6"-12"

-

5"

448002

P16FI (CE)406203

-

30"

-

5"

P16 HIJ 409701

-

10"

-

20"

448007 448010

Characteristic : P16B 402701

-

-

see

P16 AFT

-

-

448014

448009

Control unit RIELLO FUEL CONTROL BOX ACCESSORIES for 480 SE 1

2 Description

Type

Pre Purge Pre Ignition

PostIgnition

Characteristic : CSS 01-24R/E 20" Characteristic : 2 electrodes ignition and detection CSS01.12 9" Characteristic : same electrode ignition and detection CSS01-12SJV11 9" Characteristic : CSS01-24JV03 30" CSA 12 10" CSA 6 10" -

Replacement kit / cell 300 5737

Safety Time

Ref

7"

448050

12"

448064

12"

448062

24" 12" 6"

448063 448065 448066

CONNECTOR

Spare plug for replacement kit

448012 448013

CONNECTOR 10 terminals for P16 CONNECTOR 12 terminals for P16

1 2

404185 404890

NOTE : The RMO 503 SE (new model) with its release button replaces the 503SE, but not the old version of the 502SE. Pre Pre Post Safety ManufactuPurge Ignition Ignition Time rer ref.

Cell

503SE 2 + 3

Ref

Ref

503 SE type

Type

Description

Mark

34"

8"

7"

5"

300.1150

Ref

404062

483/520/522 RBO/530/531 SE/535 RSE type

1

2 Pre Purge 10"

Description

Ref

448051

APPLICATION INDEX Type P 16 A / FL 402601 P 16 C / FL 402801 P 16 D / FL 402901 P 16 DI / FL 400601 P 16 DIA / FL 400601 / V07 P 16 DI /S (NF) 400601/ V03 P 16 FI (CE) 406203 P 16 402701 P 16 FIS 406203 / V01 (CE) P 16 H 403402 P 16 HI - J 409701 CSS 01 - 24 RE CFR V 401400 P 14 110 AL CSS 01 - 12 CSS 01 - 12 SJV 11 CSS 01 - 24 JV 03 CSA 12 CSA 6

Manufacturer SOLARONICS FERROLI (NEF) / SOLARONICS / SOLARTUBE/DIFOTHERM SPAO RAY/FADIME / LAIDET SCHWANK GENERFEU/KUBBLER GAZ INDUSTRIE / EMAT / DIFOTHERM/ FADIME/AIRGARRY/JETTO BABCOCK / AIRCALO EMAT AIRCALO BABCOCK / SCHWANK SCHWANK / BABCOCK REZNOR / CIAT GENERFEU GENERFEU ETA HAMWORTHY / POWELL DUFFRYN SARGI SARGI / SMITH INDUSTRIE

BO

BASE

Base for box CSS01.24

Control unit

CFR - CSS - CSA type

Safety Time 5"

Manufacturer Type Cell Mark Ref ref. 483 SE* 3 see 530 SE 300.1132 Mectron 520 SE** 3 6" 4" 1 404071 Four 300.1156 replaces 530 SE 3 10" 10" 404894 483 SE 300.1158 531 SE 3 10" 10" for burner with 404895 preheater for RL28 522 RBO 3 10" 10" 300.3896 2 404021 to 190 burner 300.8652 for burner 535 RSE 404025 with preheater * replacement of 483 SE by 530 SE , except when delay timer on 483 SE is out of order (531 SE with Base in that case.) ** Replacement box kit + coil

550 / 552 / 553 SE type

Control box for blue flame burner (Gulliver BLU BG1). Pre Post Safety Pre Type Cell Igni- IgniTime Purge tion tion 550SE =550 IRD 5" SMD * 552SE 8" 553SE 555SE * A wiring modification is sometimes necessary.

Manufacturer ref. 300.1168 300.1174 300.1175 300.8850

Ref

404640 404265 404638 404024

CSB.253

Control unit 525 SE / RMG 88 type

RIELLO FUEL CONTROL BOX CELL

2

1

3

6

5

4

Type

Cell

525SE RMG88.62A2

Io -

Pre Pre Purge Ignition 30" -

Post Safety ManufacIgni- Time turer ref. tion 5" 300.1164 3" 301 3073

Ref

404068 404268

7 Description Replacement kit of Cell 300 5737 Spare plug for replacement KIT Cell 300 2280 for 483/530/531 SE /520 Cell 300 7839 for 552 / 553 SE Cell 300 7492 for 550 SE Cell 300.8646 for 535 SE MZ770S Cell 300.2548

Mark

Ref

1 2 5 3 4 6 7

404185 404890 404891 404639 404637 404088 404098

566 / 568 SE / MG 569 type Blue flame, oil burner control box (GULLIVER BLU BS 1/2/3/4) Pre Post Safety ManufacPre IgniPurge Ignition tion Time turer ref. MG 569 replaced 568SE and 566SE Ioniza300.1176 tion Type

Cell

Ref

404020

Control unit

BASE BASE

1

Description

2 Description

BO

2

1

BASE 300 2256 for 502/503/505/506/508 SE BASE 300 2278 for 483/520/530 SE BASE 300 2310 for 531 SE

Mark

Ref

1 2 2

404061 404889 404896

Mark

Ref

1 2

404061 404069

BASE 300 2256 for 505 /506 / 508 BASE 300 2307 for 525

RV GAS CONTROL BOX 05 type

DELAY TIMER Description

Ref

Model 0514 for SOLARONICS (SR21/31/41/42/62/82)

448002 453005

Model 05125004 for SOLARONICS/TRATHERM/RENDAMAX replaced model 05125002 and 05125003

453009

Model 05125001 for EMAT (RS22) replaced by P16DIS Description

Ref

404641

Delay timer 300 2301 G20D

RIELLO GAS CONTROL BOX 505 - 506 - 508 SE type

SATRONIC FUEL CONTROL BOX TF type

The RMG 508SE with its release button replaces the 508SE, but not the old version of the 505 + 506SE NOTE : Wiring modification supplied with the box Type

Cell

Pre Pre IgniPurge tion

Post Safety Manufacturer IgniTime ref. tion

Ref

508SE

Ionizat.

38"

-

2,5"

3"

300.1138

404067

509SE

ionizat.

35"

-

2,5"

3"

300.1139 for FS 10/15/20

404019

CSB.254

Pull-out equipment for oil burner control and security . Flame monitoring by photo-resistant cell . PostSafety Tme Ignition Characteristic : 1 firing rate - Replaces TF 701 on 1 firing rate burners Type

TF 801

Pre Purge Pre Ignition

12"

12"

20"

10"

Ref

507005

Characteristic : 2 firing rates same for 2 firing rates burners. TF 802

12"

12"

20"

10"

507006

Control unit TMO /TTO/MMO/DKW/DKO type

TF type(continuation) Pre Purge Pre Ignition

Safety Tme

3" - 5"

10"

Ref

Characteristic : 2 firing rates. TF 804

12"

12"

507007

Characteristic : With amplifier of the detection circuit. Replaces without changing the base the TF 730 with an extension cable for the release button. TF 830

12"

12"

18"

10"

507051 507064 507016

Characteristic : . 220/240V -50Hz 5VA for ECOFLAM TF 830.3

10"

10"

10"

10"

TF 974

10"

10"

10"

10"

Characteristic : 2 firing rates. TF 832

12"

12"

24"

10"

TF 840

12"

12"

5"

10"

507053 507054

Characteristic : For burner with pre-heating 1 firing rate. Replaces without changing the base the TF 734 with an extension cable for the release button. TF 834

12"

12"

18"

10"

see 507001

20"

10"

507001

Characteristic : Security low voltage. TF 834.3

12"

12"

Characteristic : Security low voltage no Post-ignition. TF 834E.3

12"

12"

-

10"

see

Type

Pre Purge

Pre Ignition

PostIgnition

Safety Time

Ref

Characteristic : DKW 972 10" 23,5" 8,5" 5" 507059 DKW 976 10" 23,5" 8,5" 5" 507061 Characteristic : Special CUENOD - ELCO SH 113 406013 replacement Kit see ER1 relay 402023 replacement Kit 402023 ER1H relay Elcopen Analyser 402025 defect NOTE : DXX type boxes, have a defect detection device. The reset switch blinks in a coding type, which indicates the defect location. A pocket size terminal type SATROPEN and PC module type SATROCOM are available on request. (1) Replaced by 507060 + (MZ cell ref 507101 if FZ cell stands or detector IRD1010 depending on brand or cell UVD ref 507003). (2) Replaced by 507062 + (MZ r cell ef 507101 if FZ cell stands or detector IRD1010 depending on brand or cell UVD ref 507003). (3) Replaced by 507060 + (detector IRD1010 depending on brand if IRD810 or 910 or 911 stands or cell UVD ref 507003). (4) Replaced by 507062 + (IRD1010 detector depending on brand if IRD810 or 910 or 911 stands or cell UVD ref 507003).

CELL

507001

Control unit

Type

PostIgnition

Characteristic : For burner with pre-heating 2 Firing rates. 12"

12"

25"

10"

507050

TF 844

12"

12"

5"

10"

507057

12"

12"

25"

10"

405002

Characteristic : TF 874

Note : TF700 boxes are replaced by Type 800 while adding an extension cable ref 507301 adjusting the reset switch level

TMO /TTO/MMO/DKW/DKO type Pull-out equipment with flame monitoring by photo-resistant cell (on medium and high power burners). ➦Remote control release. ➦With or without recycling. Pre PostSafety Type Pre Purge Ignition Ignition Time Characteristic : TMO 720-4-35 30" 30" 10" 5" Characteristic : 2 firing rates TTO 810-35 30" 30" 20" 5" TTO 836-35 30" 30" 20" 5" Characteristic : TTO 872 30" 30" 20" 5" Characteristic : Use with preheater TTO 876 20" 20" 4" 5" Characteristic : MMO 872 10" 23,5" 8,5" 5" Characteristic : preheater MMO 876 10" 23,5" 8,5" 5" Characteristic : DKO 970 DKO 972 DKO 974 DKO 976 Characteristic : Replaces TTO 810-35/ TTO 872-MMO 872 DKW 972 + prolong. 10" 23,5" 8,5" 5" Characteristic : Replaces TTO 836-35/ TTO 876-MMO 876 DKW 976 + prolong. 10" 23,5" 8,5" 5"

1

2

Description * FZ 711 S OERTLI and DE DIETRICH. special box Square plug - Red side detection * FZ 711 S white Cell - side and frontal detection for TTO 910 - TMO 720 * It is necessary to change Cell and the box

Mark

1 2

Ref To consult us

BO

TF 836

Characteristic : 1 or 2 firing rates.

SATRONIC FUEL CONTROL BOX CELL

1

2

Ref

507020 (1) (2) (3) (4) (3)

3

4

Description MZ 770 S Cell reduced, to be used only with boxes TF730-1/ TF730/ 733/734 & TF 821/822/830/834/840/740.1 - Supplied with FZ transformation taper MZ 770 long GIERSCH MZ 770 S long BROTJE Sheath and joint for MZ 770 BROTJE

Mark

Ref

1

507101

4 3 2

507102 507103 430112

SH type

(4) 507009 507012 507014 507015 507060 507062

Type

Pre Purge Pre Ignition

Characteristic : Special CUENOD - ELCO SH 213 mod C1 -

PostIgnition

Safety Time

Ref

-

5"

406019

CSB.255

Control unit KBR and TF REPLACEMENT INDEX

IRD INFRARED DETECTOR FOR FUEL

OLD BOX

1

TF20/TF21A TF22 TF 832 KBR611 KBR612 KBR612A TF 832 KBR614A KBR617A/AC

2

The monitoring function follows the infrared light vibration principle. Description MAN- BUDERUS IRD 1010 white axial shot BROTJE- BALTUR IRD 1010 blue side shot KORTING IRD 1010 blue axial shot

Mark

Ref

2 1

507339 430412 507342

NOTE : IRD 810/910/911 and 820/920 are replaced by type 1010 and 1020. you must know the brand of the device to find the right IRD detector.

BASE

2

3

Description TF 804/836/844 TF 701/730/734/801/802/830/832/834/840 / 874 TTO - MMO TMO 720 S98 for DKW/DKG/DKO/DMG

Mark

Ref

2 1 3 -

507308 507300 507310 507004

BO

Control unit

1

ADAPTATION KIT Replaced Cell Adapter Extension by with none Base to re-wire 507300

yes 507301

Use Cell MZ 507101

Base to re-wire 507300

yes 507301

TF 840

-

-

TF 701/TF714 TF 832 TF 704 TF 834

-

-

Use Cell MZ 507101 Use Cell MZ 507101 Use Cell MZ 507101 Use Cell MZ 507101 Use Cell MZ 507101 Use Cell MZ 507101 Use Cell MZ 507101

TF 740

TF 721

TF 832

-

-

TF 821 TF 822

TF 832

-

-

TF 730

TF 832

-

-

TF 734

TF 834

-

-

TF 740

TF 840

-

-

Ref

-

-

-

-

-

507023

-

507006 507007

-

-

-

-

-

-

-

-

-

-

TMO / TTO / MMO REPLACEMENT INDEX OLD BOX TTO 750-1 TTO 810 model 35 TTO 836 model 35 TTO 872 TTO 876 MMO 872 MMO 876 TMO 720 TMO 720.2 TMO 721

Replaced by DKW972 DKW972 DKW976 DKW972 DKW976 DKW972 DKW976

Note Change Cell Change Cell Change Cell Change Cell Change Cell Change Cell Change Cell

TMO 720.4

-

ACCESSORIES SATRONIC GAS CONTROL BOX MMI/ MMG/ DKG/ DMG/ TTG/ SG type

1 Description Mark Extension to find the same height with ref : TF 801 & 802 1 and ref : TF 701 Extension specific to BROTJE 1 BROTJE Joint Cell support BROTJE Glass Cell support -

Ref

507301 430733 430700 430699 Pull-out equipment with flame monitoring using ionization or UV cell (for medium and high power burners). Remote control release. With or without recycling. PrePostSafety Type Pre Purge Ref Ignition Ignition Time Characteristic : 2 Firing rates ionization replace box TTI 790-33

FR 870 MODEL

MMI 810-33

33"

3,5"

2,5"

1"

507037

3"

-

5"

507034

Characteristic : 2 Firing rates MMI 810-35

30"

Characteristic : 1 or 2 Firing rates detection by ionization or IRD Application : ✓ When it’s hard to reach heating equipment. ✓ If burner fails, difficult to be reactivated. ✓ Remote control reset is a necessary. Description FR 870 compatible with ref : TF 800/ TFI 800 / MMI / MMG and TTO 876

CSB.256

replaced by

MMI 811-35 Ref

507304

30"

-

-

5"

507063 (except Guillot)

Characteristic : 1 Firing rate ionization with air flap control MMI 812-33 MMI 812-23

63"

3,5"

2,5"

1"

replaced by

507033

Control unit PrePostSafety Ignition Ignition Time Characteristic : 2 Firing rate ionization with air flap control Type

MMI 813.1 mod 23

Pre Purge

63"

3,5"

2,5"

1"

-

-

-

5"or 10"

Ref

TTG type

507042

Characteristic : replaced by

Characteristic : 1 Firing rate ionization with air flap control MMI 962-23

63"

3,5“

2,5"

1"

507033

Characteristic : 2 Firing rates replaces without changing the base the TTG 760-33 with an extension cable for the reset switch MMG 810-33

30" 57"

TTG 760 FN

-

3"

5"

507056

3"

2,5"

3"

507058

Characteristic : replaces box MMI 811 mod. 35 DMG971

-

24"

-

3"

507063 (except Guillot)

Characteristic : replaces box MMG 810-33 TTG 760-33

30"

-

3"

3"

replaced by

507056

Characteristic : with control of parasite light and 2 Firing rates TTG 760 FN

60"

-

3"

3"

replaced by

-

-

-

10“

507049

-

21"

507065

507058

Characteristic : DKG 972

DKG 972 mod 21 Characteristic : Special CUENOD - ELCO SG 113

-

-

-

-

SG 513

-

-

-

-

406009 406020

-

-

-

-

402024

-

-

-

-

402025

Kit replacement relay EM41 Elcopen Analyser defect

TTG 760-33

Pre Purge 30"

-

3"

Safety Time 3"

Characteristic : with control of parasite light and 2 firing rates.

Characteristic : 2 Firing rates MMG 811-63

Pre IgniPosttion Ignition Characteristic : replaced by MMG 810-33 Type

NOTE : DXX type boxes have a defect detection device. The reset switch blinks in a coding type, which indicates the defect location. A pocket size terminal type SATROPEN and a PC module type SATROCOM are available on request.

60"

-

3"

3"

Ref replaced by

507056

replaced by

507058

TMG type Programmable control box and ionization flame monitoring . Designed for gas burner models, the TMG can be used with a UV sensor on fuel-oil burner equipment. Pre Pre Post- Safety Type Purge Ignition Ignition Time Characteristic : for fuel-oil and gas burner (2 Firing rates) TMG 740.3 model 32-32 replaces TMG 30" 3" 2" 740.2 model 32-32 TMG 740.3 model 43-35 replaces TMG 30" 3" 5" 5" 740.2 model 45-54

Ref

507032 507039

FFW type to REPLACE FRA - FRU DANFOSS For Atmospheric, ventilated, fuel or gas burner ✓ For semi-automatic installation. ✓ Flame formation delay : 1 second. ✓ Flame safety time delay : 1 second. Control by Ionization or cell UVZ or infrared detector IRD 1020. Description

Control unit

507049

BO

MMI 815 mod 5 MMI 815 mod 10

Ref

507320

FFW 930 FUEL - GAS

TFI / DKG type SATRONIC GAS CONTROL BOX CELL

Pull-out equipment with flame monitoring using ionization or UV cell (for medium and high power burners). Remote control release. With or without recycling. Pre PostSafety Ignition Ignition Time Characteristic : Special for REZNOR TFI 812-2 mod 10" 10E Characteristic : DKG 972 10" Characteristic : for atmospheric gas burner 2 firing rates replaces box TFI 712-10. For remote control reset use FR 870 ref 507304. TFI 812-2 maxi -10" non 10" 120 Kw mod 10 Characteristic : for atmospheric gas burner 2 firing rates replaces box TFI 712 without changing the base ; with an extension cable for reset switch. TFI 812-2 maxi 15" 5" 350 Kw mod 5 Type

Pre Purge

Ref replaced by

Description

Ref

507049

UVZ 780 red spot - UV flame control cell for MMG 810 and 811

507111

507049

UVZ 780 white spot - UV flame control cell for TMG 740-2 and 740-3 +TTG

507112

507043

UV DETECTION LAMP

507041

NOTE : DXX type boxes, have a defect detection device. The reset switch blinks in a coding type, which indicates the defect location. A pocket size terminal type SATROPEN and PC module type SATROCOM are available on request

Description SYLVANIA UV detection Lamp P607.08 Ø 22mm - 4 pin plugs

Ref

502312

CSB.257

Control unit IRD INFRARED DETECTOR

IBR - BR - GBR - TTG TFI - MMI - TMA - TMG TTI REPLACEMENT INDEX (continuation) Kit or replacement box Replaced by Adapter

OLD BOX

For Gas The monitoring function follows the infrared light vibration principle Description OLYMP -HG-HLG IRD 1020 BLEUE side shot ( IRD 920 replacement with IRD 1020 needs a M93 support)

Ref

507341

NOTE : IRD 810/910/911 and 820/920 are replaced by type 1010 and 1020. you must know the brand of the device to find the right IRD detector.

MMI 812 mod 23 MMI 812 mod 33 MMI 812-1 mod 23 MMI 812 mod 63 MMI 815 mod 5 MMI 815 mod 10 TMG 720 /TMG 740 TMG 740-1 TMG 740-2 mod 45-54 TTI 790-33

Ref

MMI 962-1 mod23

-

507033

DKG 972 TMG 740-3 mod 32-32 TMG 740-3 mod 43-35 MMI 810-33

-

507049

-

507032

terminal 1 & 9 rewire on Base

507039 507037

ACCESSORIES

2

1 Description

Control unit

M93 Magnetic support for IRD 1020 ZT 870 Transformer AZ 5 Burner

Ref

1 2

507350 805913 708790 Pre PostSafety Time Ignition Ignition Characteristic : RIELLO - SEET 0.503.902 Characteristic : WOLF - DE DIETRICH 0.503.501 Characteristic : BALTUR - ARIANE - SIME - HERMANN - UNICAL 0.537.301 type 1,5" 10" DMT Characteristic : BENESSERE - PRONTACQUE SALVASPAZIO BERETTA - RIELLO 0.537.002 type 1,5" 7,5“ DMT Characteristic : DOMUSA (CGAS 000130) 0.537.201 Characteristic : 0.537.501 Type

BASE 1

BO

Mark

SIT GAS CONTROL BOX 503 and 537 type

2

3

The extension for TFI is used to adjust the height on the old boxes (The new ones are lower) Description TMG 740 TTG - FN - MMI 811/ 812 - MMG 811/ 812 - TTG - TTI MMI 810 - MMG 810- TTI 790 - TF 804 /836/844 TFI/TMG740 DKG/DMG/DKO Extension TFI 812 Extension specific BROTJE

Mark

Ref

1

507307

-

507308

3 2 -

507300 507004 507301 430733

577 type

Pre Ignition Characteristic : GAZ INDUSTRIE Type

IBR - BR - GBR - TTG TFI - MMI - TMA - TMG TTI REPLACEMENT INDEX Kit or replacement box Replaced by Adapter Base to re-wire (estimat request) TME 780 IBR 661 cell to change (UVZE (on request) est req.) Base to re-wire (ref TMG 740-3 507302) cell to BR 661 (Ref 507032) change (ref 507112) GBR 681 or GBR MMI 810.33 (Ref Base to re-wire 681/74 507037) (Ref 507308) MMG 810 mod Terminal 1 and 9 TTG 760.33 33 rewire on base MMG 811 mod TTG 760 FN 63 TFI 712F-1 /TFI 712F TFI 812-2 mod 5 Provide switch extention 507301 TFI 812-1 mod 5 TFI 712-1 /TFI 712 TFI 812-2 mod Provide switch extenTFI 812-1 mod 10 10 tion 507301 TFI 812-2 mod 10E DKG 972 MMI 810 mod 32 MMI 810.33 Caution: pressure MMI 811 mod 35 DMG 971 switch wiring to terminals 4 and 7 OLD BOX

CSB.258

Ref

507056 507058 507041 507043 507049 507037 507063 (except Guillot)

Pre Purge

Pre Purge

0.577.503

30"

-

PostSafety Time Ignition

Ref

503008 503009 431015 404026 503010 503011

Ref

-

30"

471003

Characteristic : GAZ INDUSTRIE - BIASI 0.577.504

5"

-

-

30"

503001

-

-

-

5"

503002

-

-

-

5"

503003

-

10"

503004

-

-

55"

503005

-

-

10"

503006

-

-

10"

503007 503012 503013

Characteristic : ACV 0.577.009 Characteristic : EMAT 0.577.308

Characteristic : SAUNIER - UNICAL 0.577.311

1,5"

-

Characteristic : OERTLI - DE DIETRICH 0.577.211

-

Characteristic : DE DIETRICH 0;577.705

-

Characteristic : SAUNIER 0.577.304

1,5"

Characteristic : DE DIETRICH 0.577.702

-

-

-

-

0.577.701

-

-

-

-

Control unit STANDARD INSULATION TRANSFORMER FEATURES : ✓ ✓ ✓ ✓ L 64

Sizes l 54

IN : 220- 240V OUT : 260-280V 50 -60 HZ Power : 20VA Connection : Terminal faston 6,35 mm H 52

F 72

Fixation E 44

G -

Entraxe HT -

Description INSULATION TRANSFORMER

Ref

805961

NOTE : To increase and regulate the ionization sensor signal

IONIZATION CURRENT MONITORING - RC MODULE

Improves the value of the ionization current when, in the electric feeder systems, the zero lead has a weak potential difference with the mass of the burner. Bipolar connection between the zero lead and the mass of the burner. ✓ Size : L 25 x P10 x H 18m Description

Ref

502316

Module RC model ARC4 66890660

VARIOUS AMP and MULTICONTACT CONNECTOR

Control unit

1 2

3

APPLICATION : The ionization sensor wire comes from the control box, goes through the isolation transformer secondary and returns to the sensor. The isolation transformer primary is supplied through the same supply as the control box.. Note: be careful this transformer is a primary and secondary transformer. The fact of using the primary and the secondary is harmful.

Mark

Ref

With 3 wires cable 0,40 m for RAPA valve, SUNTEC, x6 DANFOSS Electrovalve With 3 wires cable 0,40 m for RAPA valve, SUNTEC, x1 DANFOSS Electrovalve With 3 wires cable 0,80 m for RAPA valve, SUNTEC, x6 DANFOSS Electrovalve

Description

3

803030

3

803034

3

803029

With 3 wires cable for ELCO, CUENOD ignition transformer

3

803031

4 1 2 1

803032 803033

x6

Straight male 3 pin plugs Straight female 3 pin plugs Cable with connector for preheater Angle connector Female 3 pin plugs

BO

USE: To increase and regulate the ionization sensor signal in control box installations which are not earthed neutral wired.

4

see 803036

470003

MICROAMMETER type MAP portable DOUBLE CONNECTOR

USE ✓ The micro Ammeter MAP measures the very low intensity of the ionization and UV cell current for fuel blue flame burners with ionization sensor. ✓ Checks functionning state of flame detection : ➦By ionization (burner with electrode) ➦By UV cell ✓ Measurement -10µA / 0 / +10µA, -50µA/ 0 / -50µA ou -100µA / 0 / -100µA (according to the selected model). Its zero allows measurement even if the wires are commutated.

Description Double contact connector WEISHAUPT - connector DIN

Ref

407100

A micro Ammeter is installed in series (on the same line as the probe or the cell to be measured). Description MAP -10/0/+10µA

Size : L 140 x H 85 x E 55 mm

MAP -50/0/+50µA

Size : L 140 x H 85 x E 45 mm

MAP -100/0/+100µA Size : L 140 x H 85 x E 55 mm

Ref

906567 906565 906562

CSB.259

Control unit CUENOD

DOUBLE CONNECTOR WIELAND type 1 2 Many burners are connected with a 6 male poles plug. The same piece can be connected between different installation equipment such as the circulator, and the regulation and control board. For the 6 poles plug, we choose the locking type. Anyway, the 2 parts stay pluggable, with or without a locking system. Description Male

3 poles

Female

3 poles

Male

4 poles

Female

4 poles

Male

5 poles

Female

5 poles

Male

6 poles

Female

6 poles

Male

7 poles

Female

7 poles

Type

Manufacturer ref

Ref

13010521

406008

13010979

406011

Characteristic : -

Mark

Ref

NC 4 gas - NC 6 gas - NC 9 gas grey cap

2 2 1 1 -

803050 803051 803040 803041 803010 803011 803001 803002 803020 803021

Characteristic : Base wired with preheater NC 4 - NC 6 - NC 9 grey cap

DE DIETRICH

1

2

Manufacturer Mark ref Characteristic : Base wired without preheater

PRE-WIRED BASE BROTJE

MX10 -M1.4S - M1.5S - M1.6S M1.5CS - M1.6CS - M14S M18S M19S - M18CS - M19CS - M10CS

9790-7598

Ref

1

405700

1

439118

Characteristic : Base wired without preheater M104

9795-5503

M10R -M16RS -M17RS -M16RCS M1.4RCS

9790-7599

405701

Characteristic : Base wired with preheater

BO

Control unit

Type

Type

Characteristic

0.501 M for ESB 24-28

Manufacturer ref

Ref

521185

430374 430368 430368 430368 430715 -

0.501 M for ESB 32-41

521192

0.30U for EB-U 17-25

533577

0.32U Blue Jet

533577

0.32.1 - 0.31.1 - 0.30.1 0.501 M for DU 19

539098

0.41.1 - 0.42

536004

0.112 without starter 0.112 without starter

Base wired with preheater

530309 530316

CHAPPEE

M1.3RS -M1.4RS - M1.3RCS M1.4RCS M10RD - M10RCS M10RCS

9790-7597

2

405702

M104

9795-5504

2

439119

ELCO

Manufacturer ref Characteristic : Only SIP66 Base not wired, used to repair SIP 45/46/63/64/65 pre-wired base Type

-

CAS 106295

Ref

803061

Characteristic : SIP45 Base wired without preheater EL 01A2H /A3H/ A5H

CAS 106244

402101

CAS 106684

402102

Characteristic : Base wired without preheater

2

1 Type

Manufacturer Mark ref

Ref

Characteristic : Base wired with preheater 58539864

401031 401032

58539910

1

401042

58539863

TIGRA CF 500 Characteristic : Base wired with preheater LANDIS type

CSB.260

Characteristic : SIP45 Base wired without preheater EL 03.20H / 20V/ 30H/ 30V EL 01 A3/ A5/ A8 - EL 02.9/02.15

CAS 106156

402100

Characteristic : SIP65 Base wired without preheater

1 2

TIGRA CF 500

TIGRA CF 500

EL 03B20V/30V - EL 1B3/B5/B8 - EL02B16

EL 03.20 1D/1DO - EL03.30 1D/1DO EL02.9 1D/1DO - EL02.15 1D/1DO

SIP 065

402104

Control unit IDEAL STANDARD

OERTLI

1

Manufacturer ref Characteristic : Base wired without preheater OES 310 LE - OES 130 LE 102102 Characteristic : Base wired with preheater OES 310 LEV 101754 OES 130 LEV 102104 Type

Ref

401031 401032

Ref

1

405700

2 2

405701 405702

401042

Control unit

Characteristic : Base wired with preheater HELIS 500 / HELIS MI500 58539863 Characteristic : Base wired without preheater HELIS 500 / HELIS MI500 58539864 Characteristic : Base wired with preheater LANDIS type HELIS 500 / HELIS M500 58539910

Mark

BO

Type

Manufacturer ref

2

CSB.261

Control unit IGNITION SPARK DETECTOR DEFINITION : Linked to a flame detector circuit that uses ionization electrode, the system detects a flame signaling a spark. It replaces the UV cell for ignition spark detection when the use is compromized.

IGNITION SPARK DETECTOR model DA51 ECEE ref : diff 501660

IGNITION SPARK DETECTOR model QRE1 Landis and Gyr ref : diff 502315 or model RT1 Brahma ref : diff 504220 Note : In both cases, the high frequency wave created by the ignition spark, provides a necessary contact when ionization sensor current goes through. The detection avoids trouble in case of short-circuit electrode.

BO

Control unit

INFORMATION On fuel or gas burners, the modernization and miniaturization of control boxes allow rapid and safe maintenance, through the use of microprocessors. On the new generation relays, breakdowns indeed are automatically detected by electronics, thus enabling quick diagnosis and reducing attendance.

LMO (replacing soon LOA relays) and LMG (replacing soon LGB relays) have a very fine process. Through a blinking light code, they show the cause of the failure

Failure code tables Blinking code Blinking 2x

••

Blinking 4x

LMO

••

flame disappearing too often ✓ Defective or clogged fuel valves ✓ Defective or clogged cell ✓ Bad burner adjustment

••••

•••• Blinking 7x

•••••••

Blinking 8x

Time control of the fuel preheater

•••••••• Blinking 10x

••••••••••

Blinking code

Cause no flame at the end of “TSA” ✓ Defective or clogged fuel valves ✓ Defective or clogged cell ✓ Bad burner adjustment or no fuel ✓ Defective ignition system parasite light when burner starts

Bad wiring, internal defect or output contacts

Blinking 2 x

Blinking 3x

•••

Blinking 4x Blinking 5x

•••••

Blinking 7x

••••••• Blinking 18x

•••••••••• •••••••• Blinking 19x

•••••••••• ••••••••• Blinking 20x

•••••••••• ••••••••••

CSB.262

LMG

Cause no flame at the end of "TSA" ✓ Defective or clogged fuel valves ✓ Defective or clogged electrode/cell ✓ Bad burner adjustment Pressure switch does not close ✓ Defective "LP" ✓ "LP" not adjusted ✓ the fan does not function Pressure switch does not open; parasite light when burner starts ✓ Defective "LP" ✓ "LP" not adjusted parasite light during preventilation or internal defect flame stops during the operation ✓ Bad burner adjustment ✓ Defective or clogged fuel valves ✓ Short circuit between ionization electrode and earth the pressure switch opens during preventilation or operation ✓ "LP" badly adjusted ✓ flame stops for the 4th time defective ouptput contacts ✓ Bad wiring ✓ Or another power supply at the output internal defect