OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Part: No.:

GAA21000CJ_TS1

Vint Vintag age e: 01 / 1

Trouble shooting Guide (Draft)

ENGINEERING CENTER BERLIN

Page:

1/ 43

Date:

Nov. 8, 02

GeN2  T r o u b l e Sh Sh o o t i n g G u i d e  

 Authorization Date D1:

Draft

Running on PCB:

MCBIII: GAA26800KF1 TCBC TCBC:: GAA2 GAA268 680 00KA1, KA1,2 2,3

SPBC: GAA26800KB DCSS5: SS5: GAA GAA2435 4350BD1 0BD11 1

Software Ve Version:

MCBIII: GAA30762BAA TCBC: GAA230081AAB

SPBC: GAA30760AAB DCSS5: GAA30328AAE

Document Revision : Date

Author

Nov. 8, 02

M. Toutaoui

Pages

Comment Original Document

Copyright 2002, OTIS GmbH & Co. OHG Berlin. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of OTIS GmbH & Co. OHG.

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

Part: No.:

GAA21000CJ_TS1

Vint Vintag age e: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

Page:

2/ 43

Date:

Nov. 8, 02

CONTENTS 1

Elevat Elevator or status status and failure failure classif classificat ication ion ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ... 5

2

Troubl Trouble e shootin shooting g flow flow chart chart ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ... 6

3

Visual Visual check check on E & I pane panell ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ..... 7

4

Manual Manual Rescue Rescue Operati Operation on (MRO) (MRO) ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ..... .. 11 4.1 Condit Condition ions s for not lifting lifting the brake brake via MRO ........ ............ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ....... ... 11 4.2 Brake release release checks checks ...................... ................................ ..................... ...................... ...................... ..................... ..................... .................. ....... 11

5

Failur Failure e handli handling ng on the SPBC SPBC ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ..... 12 5.1 Service Service Tool communic communication ation failures failures ..................... ................................ ...................... ...................... ...................... ................ ..... 12 5.2 Failures Failures displayed displayed on SDI....................... SDI................................. ..................... ...................... ...................... ...................... ..................... .......... 12

6

Failur Failure e handli handling ng on TCB TCBC.... C....... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ..... 15 6.1 Blinking Blinking event event messages................... messages.............................. ..................... ..................... ...................... ...................... ...................... ............... .... 15 6.2 Operating Operating system system related related failures failures ..................... ................................ ...................... ...................... ..................... ..................... ........... 17 6.3 Operationa Operationall control control subsyste subsystem m related related failures................. failures............................ ..................... ..................... ................. ...... 17 6.4 Motion Motion control control subsyste subsystem m related related failures......... failures................... ..................... ...................... ...................... ..................... ............ 19 6.5 Door Door contro controll subsy subsyste stem m related related failur failures es ........ ............ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ...... 20 6.6 Signaling Signaling subsystem subsystem related related failures ..................... ................................ ...................... ..................... ..................... ................. ...... 21 6.7 Group function function related related failures........ failures................... ...................... ...................... ...................... ...................... ....................... ................. ..... 21 6.8 System System related related failures failures ..................... ................................ ...................... ...................... ...................... ...................... ...................... ............... .... 22

7

Failur Failure e handli handling ng on MCBIII MCBIII ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ... 23 7.1 System System (SYS) related related messages................ messages........................... ...................... ...................... ...................... ...................... ................ ..... 23 7.2 Inverter Inverter (INV) related related messages.............. messages......................... ...................... ...................... ...................... ...................... ................... ........ 25 7.3 CAN bus related related messages................... messages.............................. ...................... ..................... ..................... ..................... ..................... ............. 26 7.4 Motion Motion commands commands (MC) related related messages messages ..................... ................................ ...................... ...................... ................. ...... 27 7.5 Analog Analog load weighing weighing (ALW) related related messages messages ..................... ................................ ...................... ..................... .......... 29 7.6 Motion Motion logic state (MLS) related related messages......... messages.................... ..................... ..................... ..................... ................... ......... 29 7.7 Drive Drive control control (DRV) related related messages messages ..................... ................................ ...................... ..................... ..................... .............. ... 31 7.8 Learn run (LRN) and encoder encoder adjustmen adjustmentt (ADJ) (ADJ) related related messages messages............ ....................... ........... 33

8

DCSS5 DCSS5 related related failure failures s ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ..... 35

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

Part: No.:

GAA21000CJ_TS1

Vint Vintag age e: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

Page:

2/ 43

Date:

Nov. 8, 02

CONTENTS 1

Elevat Elevator or status status and failure failure classif classificat ication ion ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ... 5

2

Troubl Trouble e shootin shooting g flow flow chart chart ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ... 6

3

Visual Visual check check on E & I pane panell ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ..... 7

4

Manual Manual Rescue Rescue Operati Operation on (MRO) (MRO) ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ..... .. 11 4.1 Condit Condition ions s for not lifting lifting the brake brake via MRO ........ ............ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ....... ... 11 4.2 Brake release release checks checks ...................... ................................ ..................... ...................... ...................... ..................... ..................... .................. ....... 11

5

Failur Failure e handli handling ng on the SPBC SPBC ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ..... 12 5.1 Service Service Tool communic communication ation failures failures ..................... ................................ ...................... ...................... ...................... ................ ..... 12 5.2 Failures Failures displayed displayed on SDI....................... SDI................................. ..................... ...................... ...................... ...................... ..................... .......... 12

6

Failur Failure e handli handling ng on TCB TCBC.... C....... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ..... 15 6.1 Blinking Blinking event event messages................... messages.............................. ..................... ..................... ...................... ...................... ...................... ............... .... 15 6.2 Operating Operating system system related related failures failures ..................... ................................ ...................... ...................... ..................... ..................... ........... 17 6.3 Operationa Operationall control control subsyste subsystem m related related failures................. failures............................ ..................... ..................... ................. ...... 17 6.4 Motion Motion control control subsyste subsystem m related related failures......... failures................... ..................... ...................... ...................... ..................... ............ 19 6.5 Door Door contro controll subsy subsyste stem m related related failur failures es ........ ............ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ...... 20 6.6 Signaling Signaling subsystem subsystem related related failures ..................... ................................ ...................... ..................... ..................... ................. ...... 21 6.7 Group function function related related failures........ failures................... ...................... ...................... ...................... ...................... ....................... ................. ..... 21 6.8 System System related related failures failures ..................... ................................ ...................... ...................... ...................... ...................... ...................... ............... .... 22

7

Failur Failure e handli handling ng on MCBIII MCBIII ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ... 23 7.1 System System (SYS) related related messages................ messages........................... ...................... ...................... ...................... ...................... ................ ..... 23 7.2 Inverter Inverter (INV) related related messages.............. messages......................... ...................... ...................... ...................... ...................... ................... ........ 25 7.3 CAN bus related related messages................... messages.............................. ...................... ..................... ..................... ..................... ..................... ............. 26 7.4 Motion Motion commands commands (MC) related related messages messages ..................... ................................ ...................... ...................... ................. ...... 27 7.5 Analog Analog load weighing weighing (ALW) related related messages messages ..................... ................................ ...................... ..................... .......... 29 7.6 Motion Motion logic state (MLS) related related messages......... messages.................... ..................... ..................... ..................... ................... ......... 29 7.7 Drive Drive control control (DRV) related related messages messages ..................... ................................ ...................... ..................... ..................... .............. ... 31 7.8 Learn run (LRN) and encoder encoder adjustmen adjustmentt (ADJ) (ADJ) related related messages messages............ ....................... ........... 33

8

DCSS5 DCSS5 related related failure failures s ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ..... 35

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER BERLIN

9

Part: No.:

GAA21000CJ_TS1

Vint Vintag age e: 01 / 1

Trouble shooting Guide (Draft)

Page:

3/ 43

Date:

Nov. 8, 02

GLOSSA GLOSSARY RY ...... ......... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ...... ..... 36

10 Reports Reports for feedback......... feedback.............. ........... ........... ........... ........... ........... ........... ........... ........... ........... ........... ........... ........ 39 10.1 Elevator Elevator status status ...................... ................................. ...................... ...................... ...................... ..................... ..................... ...................... ................. ...... 39 10.2 Event Event logging logging list to be filled out out .................... ............................... ...................... ...................... ...................... ..................... ............. ... 40 10.3 Parameters Parameters relate related d to MCBIII MCBIII ....................... .................................. ...................... ...................... ...................... ...................... .............. ... 41 10.4 Parameters Parameters related related to TCBC ...................... ................................. ...................... ...................... ...................... ...................... ................ ..... 42 10.5 Parameter Parameter related related to DCSS5 DCSS5 ...................... ................................. ...................... ...................... ...................... ...................... ................ ..... 43

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Part: No.:

GAA21000CJ_TS1

Vint Vintag age e: 01 / 1

ENGINEERING CENTER

Trouble shooting Guide (Draft)

BERLIN

Page:

4/ 43

Date:

Nov. 8, 02

INTRODUCTION The trouble shooting guide helps to analyze the failure when disturbances are occurring and describe the way how to proceed to repair the failure. The guide includes several parts concerning the different sub-components being part of the GeN2 system. The different parts of the t he trouble shooting guide are listed below. Part

Title

1

Elevator status and failure classification

2

Trouble shooting flow chart

3

Visual check on the E & I – Panel • LED’s SDI • Service buttons •

4

Manual Rescue Operation (MRO)

5

Failures handling on the service operation (SPBC)

6

Failures handling on the operating system (TCBC)

7

Failures handling on the drive system (MCBIII)

8

Failures handling on the door system (DCSS5)

9

Glossary

10

Feedback reports for root cause analysis including: • Elevator status • Error logging list • Parameter list (MCBIII, TCBC, DCSS5)

In case of failures which are not handled in this document and if the trouble is not located, then: 

Fill out the event logging report for: TCBC and/or MCBIII and/or SPBC and/or DCSS5



Note all remarks concerning the disturbance



Send the report back for root cause analysis

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

ENGINEERING CENTER BERLIN

Page:

5/ 43

Date:

Nov. 8, 02

1 Elevator status and failure classification For your own documentation only 

Please mark with a cross the right status

Status

Observation



elevator is running with failure

_________________________________________________ 



elevator is blocked

_________________________________________________  



1) Floor:

_________________________________________________  

a) Hoistway and car door opened

_________________________________________________ 

b) Hoistway door closed

_________________________________________________  



2) Between the floors

and

_________________________________________________  

The list given below shows the possible failures related to the GeN2 electrical system. The failures are classified according to the corresponding root cause.

Failure occurring due to ...

Class

Safety chain (broken)

SAF

Defective parts: PCB, speed encoder, EPROM, EEPROM Switch, Sensor 

DEF

Wrong wiring

WIR

Missing voltage (power supply)

POW

Input not available or missing signal

SIG

Wrong operation

OPE

Wrong parameter setup

PAR

Defective battery function

BAT

Wrong communication (CAN-bus)

COM

Wrong measurement

MEA

Sticky brake lining (speed encoder)

BRA

No failure, for information only

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

2

Part:

Trouble shooting flow chart

Page:

6/ 43

Date:

Nov. 8, 02

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

ENGINEERING CENTER BERLIN

Page:

7/ 43

Date:

Nov. 8, 02

3 Visual check on E & I panel SPBC SERVICE PANEL BOARD with CAN This part includes: Contract speed information Battery charge status SPBC functionality and communication check

• • •

Please mark with a cross the right status

Signal CON-SPEED

BAT-CHARGE

MAINTENANCE

FAULT

SPB_OK

LED Status

What does the status mean

off

low / no speed; speed is lower than contract speed (v115%v nom during Normal run

OPE

off

Battery absent or over voltage fault

BAT

on

Fast charging

blinking

Pre-charge qualification

off

Pre-charge qualification / Fast charging

on

Maintenance charging

off

Pre-charge qualification/ Fast charging/ Maintenance charging

on

Battery absent or over voltage fault / charging fault

BAT

blinking

Charge pending (temperature out of range)

BAT

off 



No power 



Check the battery and power supply

POW

on



Self test failed



Replace the SPBC

DEF

blinking

SPBC local software is properly running, self test passed

off

SPBC supplied from controller  

on

Not defined

BAT-MODE blinking

CAN_OK

For your own documentation only 



'Battery mode'



main switch is off 

BAT  

Check the power supply wiring from TCBC Operate main switch (OCB)

POW

DEF

off

CAN Bus not available (e.g. CAN wire is broken)

COM

on

Not defined

COM

blinking

CAN Bus available

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

Page:

8/ 43

Date:

Nov. 8, 02

VISUAL CHECK on E & I panel (continued) SPBC SERVICE PANEL BOARD with CAN This part includes: • • • •

Information related to the MCB functionality The elevator status for a normal or  inspection run Information related to the door function Information related to the safety chain

Please mark with a cross the right status

Signal GRP

NOR

LED Status

For your own documentation only 

What does the status mean

off

No Group function

on

Group function okay

on

Normal Mode

off

NAV, DTO, DTC, ATT, CHC, EFO, EFS, ISC, drive-fault

OPE

blinking

The Hoistway access detection (ACC)is active. Release through ERO or power off 

OPE

OPE

on

ES

off

Inspection Mode (TCI or ERO operated) TCI-Lock function active (Top of car procedure not correctly followed) No emergency stop

DW

on

Door Wiring (Hoistway door contacts closed)

DFC

on

Door Fully Closed (Safety chain closed)

DOL

on

Door Open Limit ( front or rear ) reached

DOB

on

Door Open Button operated

INS

blinking

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

ENGINEERING CENTER

Trouble shooting Guide (Draft)

BERLIN

Page:

9/ 43

Date:

Nov. 8, 02

VISUAL CHECK on E & I panel (continued) SPBC SERVICE PANEL BOARD with CAN This part includes the service buttons used for  different needs, like Car call to top/bottom landing Cancel hall call Disable door operation Remote tripping/resetting • Brake release buttons REM service button •

Signal

LED Status

What does the status mean

CCTL

on

Car Call to Top Landing (button is operated)

CHCS

on

Cancel Hall Call Switch (button is operated) Test button to display the errors at SDI, when car position is blinking

TEST CCBL

on

Car call to Bottom Landing (button is operated)

DDO

on

Disable Door Operation (button is operated)

NURF

on

Emergency Power Test (button is operated)

RTB

on

Remote Tripping Button (button is operated)

REB

-

RRB

on

Common Button for RTB & RRB Remote Resetting Button is operated

Note: RRB or RTB are only accepted if REB is pressed simultaneously  BRB1

BRB2 REM REB & TEST

on

Brake supply apparent, Automatic Manual Brake Release and BRB2 ON

off

off

No voltage on brake supply connection (Pn: Brake) Voltage supplied for Automatic Manual Brake Release Also on at activated brake during normal run (voltage feedback) No voltage supplied for Automatic Manual Brake Release

off

Out of Service Button (not active)

on

-

Reset (start self test); not possible at Bat-Mode

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

Page:

10/ 43

Date:

Nov. 8, 02

VISUAL CHECK on E & I panel (continued) SPBC SERVICE PANEL BOARD with CAN This part shows the errors displayed on the SDI, when the car position is blinking: •



The errors displayed on the SDI by pushing the TEST button (LED's are on) 8 green LED's for upwards 8 green LED's for downwards The elevator car status at the door zone

Please mark with a cross the displayed error 

Signal

LED Status

For your own documentation only 

What does the status mean

15

UP

14 15 14 13 12

Received out of range parameters

PAR

12

Three encoder A faults, stored in E2PROM

DEF

11

11

10 9

10

HTS failure

DEF

9

DZI failure

SIG

8

Over speed was reached

MEA

7

No communication with master  

COM

5

Battery failure

BAT

4

E2PROM failure

DEF

3

Measured direction does not match dictated direction

MEA

2

Encoder B failure

DEF

1

Encoder A failure

DEF

0

Task timing error  

MEA

8

DZ 7 6 5 4 3 2 1 0

Signal

13

6

LED Status off

DZ

on

What does the status mean Outside Door Zone (No DZ Signal) Inside Door Zone (Interruption of Automatic Manual Brake Release, Buzzer)

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

Page:

11/ 43

Date:

Nov. 8, 02

4 Manual Rescue Operation (MRO) 4.1 Conditions for not lifting the brake via MRO Possible state or message

Reason

SPBC is not in Battery mode

Controller is not switched off  

Error # 4 on SDI is detected

E2PROM failed

Error # 7 on SDI is not detected

Communication with master is established

Error # 8 on SDI is detected

Over speed is detected (governor not tripped)

Error # 12 on SDI is detected

Encoder A error  

Error # 13 on SDI is detected

Parameters are out of range

4.2 Brake release checks Function  Activation of BRE

Button BRB1 BRB2 pressed

LED status BRB1 BRB2

Possible reason

If the car does not move, then: Key locked blinking blinking • empty battery due to a too long rescue operation • Parameters are not OK



Car in balance

What to do  

charge battery

set default values on TCBC: M-1-3-1-7  bring weights on the top of the car 

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

Page:

12/ 43

Date:

Nov. 8, 02

5 Failure handling on the SPBC 5.1

Service Tool communication failures

SVT: System Menu is not available (only SPBC) Possible reason

What to do



TCBC has no CAN connection



check CAN wire between TCBC and SPBC

WIR



TCBC is powered down



search cause for missing power 

POW



TCBC is defect



replace TCBC

DEF

SVT: MCBIII is not available (only SPBC) Possible reason

What to do



MCBIII has no CAN connection



check CAN wire between TCBC and MCBIII

WIR



MCBIII is powered down



search cause for missing power 

POW



MCBIII is defect



replace MCBIII

DEF

5.2

Failures displayed on SDI

When the car position is blinking, then an error has occurred. Press TEST button to display the errors at SDI. TEST shows event ‘00’ Possible reason •

hardware/software failure

What to do 

replace SPBC

DEF

SDI blinking in both directions while stopping. TEST shows event ‘01’ Possible reason •

no signals from encoder-track A

What to do 

check rescue encoder wiring

WIR



replace rescue encoder 

DEF

SDI shows speed in both directions. TEST shows event ‘02’ Possible reason •

no signals from encoder-track B

What to do 

check rescue encoder wiring

WIR



replace rescue encoder 

DEF

SDI shows speed in both directions. TEST shows event ‘03’ Possible reason • •

rescue encoder-track A and B are exchanged rescue encoder B is defect



What to do change SDI-DIR parameter (0->1 or 1->0) or exchange pin4 and pin 5 at SPBC



replace rescue encoder 

OPE DEF

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

Page:

13/ 43

Date:

Nov. 8, 02

SDI mostly shows correct direction. TEST shows event ‘03’ Possible reason • • • 

rescue encoder-track A and B are exchanged invalid phase shift between encoder– track A and B Rollbacks



What to do change SDI-DIR parameter (0->1 or 1->0) or exchange pin4 and pin 5 at SPBC



replace rescue encoder 

DEF



adjust the drive to prevent rollbacks

OPE

PAR

SDI blinking in both directions while running Possible reason •

no signals from rescue encoder 

What to do 

check rescue encoder wiring

SIG



replace rescue encoder 

DEF

TEST shows event ‘04’ Possible reason •

E2Prom of SPBC is defective. After  loss of power the direction and scale of SDI is not reliable any more.

What to do 

Replace SPBC DEF

TEST shows event ‘05’ (only SPBC) Possible reason •

Battery is defect. The SPBC will have no power supply if the controller is switched off.

What to do 

Replace battery

BAT



check battery wiring

WIR

TEST shows event ‘07’ Possible reason •

no CAN communication with master 

What to do 

check power supply of TCBC

POW



check CAN_OK led at TCBC

COM



check CAN wiring between TCBC and SPBC

WIR



check ground connection between SPBC and TCBC

WIR

TEST shows event ‘08’ Possible reason

What to do



car has reached over speed



check encoder parameter EncoderWidth

DEF



OS safety contact has opened parameter NomSpeed  is too small for  this unit



reset contact check parameter NomSpeed 

OPE

• 



PAR

TEST shows event ‘09’ Possible reason •

DZI is not wired / available

What to do 

check DZI and its wiring

WIR

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

Page:

14/ 43

Date:

Nov. 8, 02

TEST shows event ‘10’ Possible reason •

The HTS temperature is higher than the parameter HtsMax.



What to do Shut down the complete System. Wait until the environment temperature is cooling down at the floor with the E&I panel.

OPE

TEST shows event ‘12’ Possible reason •

Encoder A fails 3 times



What to do erase events (at TCBC with SVT); check encoder A wire; start a controlled run



What to do check all parameters (see chapter ‘Communication / CAN messages to the SPBC’)

DEF

TEST shows event ‘13’ Possible reason •

one or more parameters (received from TCBC) is out of range

PAR

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

ENGINEERING CENTER

Trouble shooting Guide (Draft)

BERLIN

Page:

15/ 43

Date:

Nov. 8, 02

6 Failure handling on TCBC 6.1

Blinking event messages

wrongBoard Possible reason •

The software cannot identify the board.

What to do 

replace the TCBC.

DEF

Learn Run Possible reason • •

The drive package is performing its Learn Run The drive package is adjusting the encoder.

DoorBridge

What to do wait until the learn run is completed.

DW or DFC input has not been low while the door was opened. Possible reason



bridged door lock.

Switch INS

What to do 

check safety chain



This event is stored into EEPROM so that the ONLY way to bring the elevator into operation again is by using INS.

Elevator is taken out of service. Possible reason



SIG

Landing door was opened for longer  than 2 seconds.



What to do This event is stored into EEPROM so that the ONLY way to bring the elevator into operation again is by using INS.

OPE

TCI-lock Possible reason



What to do The sequence to leave TCI-mode was  Correct steps are: 1. open door  not correctly followed 2. switch TCI off  3. close door 

OPE

1LS+2LS on Possible reason •

Limit switches 1LS and 2LS are active at the same time.



What to do Check power supply of the position reference system.



What to do Set I/O 691 to a valid address

POW

Adr-Check Possible reason •

Some RSL I/Os have to be programmed to a valid address and are not allowed to be set to 00-0 or 01-0. Currently only one I/O is checked: 691 – TCI

SIG

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

Page:

16/ 43

Date:

Nov. 8, 02

SE-Fault Possible reason •

The car cannot start due to missing SE-signal

What to do 

Check the door bypass



What to do The drive is powered down to allow cooling.



What to do The drive is powered down to allow cooling.

SIG

1TH-Fault Possible reason •

The DBR-contact which is connected to the input 1TH is opened.

SIG

2TH-Fault Possible reason •

One of the contacts which is connected to the 2TH is opened.

SIG

PowerSave The drive package is currently switched off to save energy. start DCS! Possible reason •



Normal operation is not allowed until the Door Check Sequence has been completed successfully. The DCS is required again if one of  the parameters TOP or BOTTOM is changed.



What to do Enter M-1-3-5 to start the DCS! OPE

Shutdown Possible reason

What to do



The drive reports a Shutdown



See event logging of MCBIII.



CAN-Communication not working



check CAN-wiring



check CAN-LEDs



What to do Switch on the car light switch/related setup: MCLS (697)



Check the car light relay/related setup: CLR (1000)

OPE COM

MCLS/SKL-3 Possible reason • •

Car Light Switch in Machine Room has been switched off  Car Light Relay on top of car is dropped.

OPE

PAR

LBG/CSP-2 Possible reason •

Light Beam Gate has been active.

What to do 

check related setup: LBG (967)

PAR

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

Page:

17/ 43

Date:

Nov. 8, 02

SPB: HTS Possible reason •

Hall Temperature Sensor from Service Panel Board is activated. Car is shutdown at next commitable floor  and taken out of service



What to do Wait until the temperature is lower than parameter SPBtemperature

SPB-Comm. Possible reason •

6.2

CAN-Communication to SPBC is not working.

What to do 

check CAN-wiring



check CAN-LEDs

COM

Operating system related failures

Task Timing software entered endless loop W_Dog Reset watchdog circuit on LCBII was triggered Illegal Int illegal interupt was executed CanTxFull CAN messages cannot be sent CanBusOff  CAN communication has been restarted MCB-Comm. No CAN connection to the drive SPB-Comm. No CAN connection to the SPBC Note: the above information (wrong software run and communication) is for engineering only 

6.3

Operational control subsystem related failures

OpMode NAV OCSS is not available due to drive fault (e.g. drive-fault (NR). This mode is also active after INS before the COR starts EPO shutd. Possible reason •

car is not able to run during EPO; the next car is allowed to recover 

What to do 

related setup: NU (017) NUSD (018) NUSG (019)

OPE

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

Page:

18/ 43

Date:

Nov. 8, 02

OpMode DTC Possible reason •

door was not able to close (missing DCL, DFC or DW) within timeout

What to do 

related setup DCL (694) RDCL (695) DOOR, REAR DTC-T

SIG

OpMode DTO Possible reason •

door was not able to open (missing DOL) within timeout

What to do 

related setup DOL (000) RDOL (544) DOOR, REAR DTO-T

PAR

OpMode DCP Possible reason •

car was not able to answer a call within timeout (e.g. door was held open manually)

What to do 

related setup DCP-T 

PAR

PDS active Possible reason •

partition door switch is opened

What to do 

related setup PDD  (784)

PAR

DS bypass Possible reason •

Malfunction of Disable Door Switch Relays (DDSR) for Generic Firemen Service.

What to do 

related setup DDSRC  (970)

PAR

EEC bypass Possible reason •

Malfunction of Disable Emergency Exit Contact Relay (DEMERC) for  Generic Firemen Service.

What to do 

related setup DEMERC  (971)

PAR

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Trouble shooting Guide (Draft)

BERLIN

 A correction run was performed (e.g. after INS, NAV)

 /ES in FR

ES-input was activated during Fast Run

 /ES in SR

ES-input was activated during Slow Run

TCI/ERO on

TCI or ERO has been switched on

SE-Fault

SE signal is missing Possible reason

The car cannot start due to missing SE-signal

 /DZ in NST





Date:

Nov. 8, 02

Check the door bypass

SIG

The inputs signals 1LV, 2LV on MCBIII are missing CAN-Communication not working



What to do Check the input signals on MCBIII



check CAN-wiring



check CAN-LEDs

SIG

COM

car door has been opened during Fast Run Possible reason

DFC input signal is missing

 /DFC in SR

What to do 

check the signal

SIG

car door has been opened during Slow Run Possible reason



19/ 43

DZ-signal was lost or not detected at all after having stopped

 /DFC in FR •

Page:

What to do

Possible reason •

GAA21000CJ_TS1

Motion control subsystem related failures

Correct.Run



No.:

Vintage: 01 / 1

ENGINEERING CENTER

6.4

Part:

DFC input signal is missing

What to do 

check the signal

SIG

DrvShutdown Possible reason • •

The drive reports a Shutdown CAN-Communication not working

What to do 

See event logging of MCBIII.



check CAN-wiring



check CAN-LEDs



What to do The drive is powered down to allow cooling.

OPE COM

1TH-Fault Possible reason •

The DBR-contact which is connected to the input 1TH is opened.

SIG

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

ENGINEERING CENTER

Trouble shooting Guide (Draft)

BERLIN

Page:

20/ 43

Date:

Nov. 8, 02

2TH-Fault Possible reason •

One of the contacts which is connected to the 2TH is opened.



What to do The drive is powered down to allow cooling.

SIG

RSL Adr Chk Possible reason •

Some RSL I/Os have to be programmed to a valid address and are not allowed to be set to 00-0 or 01-0. Currently only one I/O is checked: 691 – TCI



What to do Set I/O 691 to a valid address related setup: TCI(691) PAR

PowerSave Possible reason •

The drive package has been powered on

 /DW in FR

What to do 

related setup: PDR-D

landing door has been opened during Fast Run Possible reason



DW input signal is missing

 /DW in SR

What to do 

check the signal

6.5

SIG

landing door has been opened during Slow Run Possible reason



PAR

DW input signal is missing

What to do 

check the signal

SIG

Door control subsystem related failures

DBP: dfc_SE Possible reason •

While the door was opening or fully opened, the door bypass was found to be inactive (DFC low or SE h igh)

What to do 

related setup: EN-RLV , EN-ADO

PAR

DCL in [ ] Possible reason •

(R)DCL was active while the door was fully opened

DoorBridge

What to do 

related setup DCL (694) RDCL (695

PAR

DW or DFC was not low during the last door cycle Possible reason

What to do



the safety chain is bridged



remove the bridge

SAF



the Door Bypass is defect



check the door bypass

DEF

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

ENGINEERING CENTER

Trouble shooting Guide (Draft)

BERLIN

Page:

21/ 43

Date:

Nov. 8, 02

DOL:alw. on Possible reason •

(R)DOL was active while the door was fully closed. This event is also logged when the fuses of the door system are burned. This event is not logged within the first 40 seconds after system startup.

What to do 

related setup DOL (000) RDOL (544)

PAR

Hwy Access Possible reason •

6.6

Landing Door was opened.

What to do 

see description for blinking message 'Switch INS'

Signaling subsystem related failures

RSL parity

Two remote stations with the same address are connected to the same link Possible reason



What to do 

Wrong connection

RSL sync

Check the RS connections

WIR

Synchronization lost on remote serial link Possible reason



OPE

Line terminator is defective

What to do 

Change the line terminator 

6.7 Group function related failures RNG1 msg data error on Duplex/Triplex ring RNG1 time no ring messages received from other car for a specific time RNG1 sio framing error on Duplex/Triplex ring RNG1 tx ring messages couldn't be sent in an appropriate time

DEF

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

BERLIN 6.8

Part:

Page:

22/ 43

Date:

Nov. 8, 02

System related failures



The Service Panel Board detected a malfunction which hinders a manual rescue operation with SPBC and SDI. Possible reason What to do  Press the SPBC-buttons REB + DDO simultaneously to defective speed encoders for SDI locate the error. defective E2PROM on SPBC



Missing battery for SPBC

SPB-Alert



DEF DEF BAT

SPB:TempHTS Possible reason •

The Service Panel Board detected an over temperature.

What to do 

related setup SPB-Temp

PAR

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

ENGINEERING CENTER

Trouble shooting Guide (Draft)

BERLIN

Page:

23/ 43

Date:

Nov. 8, 02

7 Failure handling on MCBIII  Actual errors: ;saved errors: 7.1

System (SYS) related messages

SYS : Warmstart

Software reset without power reset

Possible reason •





What to do 

defective EPROM

time was not sufficient to store all occurred events into the saved event logging



hardware problem



SYS : Shut down

the error which caused the shut down is displayed with

SYS : DDP

MEA

change MCBIII

DEF



What to do Message allows a quick overview over the last shut downs, for further information refer to the concerned event.

What to do



DDP time exceeded (default: 20 sec)



LV magnet is missing



The time between two positive edges of LV-magnets was shorter than the DDP time adjusted by SVT.



The DDP time error is often caused by other events.

SYS : E2P failure



EEPROM writing or reading problems

no EEPROM on the MCBIII defective EEPROM

What to do  



defective MCBIII

SYS : E2P Default

plug EEPROM correctly start self test: M-2-3 - 0 = Self test was not yet executed - ? = Executing the self test - + = Self test O.K. - = Self test not O.K. if negative, then change EEPROM change MCBIII

DEF

DEF

DEF

 All parameters are set to their default values.

Possible reason •

SIG

MEA

Possible reason •

OPE

The elevator is blocked (DDP time error) Possible reason



DEF

 A run was interrupted because of a shut down error.

Possible reason •

start self test: M-2-3 - 0 = Self test was not yet executed - ? = Executing the self test - + = Self test O.K. - = Self test not O.K. if negative, then change EPROM the error can be neglected if it occurs in the saved event logging

The unit is not able to run with default values.



What to do If the parameters were stored by SVT (M-3-7) the setup can be reload by SVT (M-3-8). Otherwise the unit has to be readjusted again.

PAR

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

ENGINEERING CENTER

Trouble shooting Guide (Draft)

BERLIN

Page:

24/ 43

Date:

Nov. 8, 02

SYS : E2P InvPara

• •

 Any parameters stored in the EEPROM are outside the range of their minimal or  maximal values. Possible reason What to do Note all parameters, set DEFAULT parameters, readjust  error occurs when the EEPROM is the parameters again. removed and replaced with new one  Change EEPROM. EEPROM self test (M-2-3) failed

PAR DEF

Sub-code for further information: Press or p



number of parameter which is out of range (EEPROM(p): information for Engineering only

SYS : ParaConflkt

The parameter ConNmot  is inconsistent with other parameters.

Possible reason •

The maximum INS SPE  is at synchronous speed of the motor, the maximum NOM SPE  is at 110 % of  the synchronous speed of the motor.

SYS : Power fail

What to do 

Check the parameters: CON SPE , ConNmot , Motor Type (M-3-1-GOON), MotFnom, MotNom (M-3-5-1-GOON), INS SPE , NOM SPE  (M-3-2-GOON).

PAR

The line voltage was outside its specified range for a short time (e.g. one phase is lost).

Possible reason

What to do



voltage loss (line)



check line connections L1 to L3

POW



short voltage drop or voltage variation



verification of line voltages with recorder necessary

POW

SYS : < 24V Supply

24V power supply is missing on MCBIII

Possible reason external short circuit in the 24VDC power supply





defective MCBIII



What to do switch off the unit, remove all plugs, out of P1, then switch on the inverter and check if an error message will indicate, if not then the wiring is faulty change MCBIII



defective PDB



change inverter section



SYS : < 15V Supply

What to do

see error 'SYS: Time

Possible reason

What to do



acceleration rate is too high



decrease acceleration rate ”DEC” (M-3-3-goon)

PAR



power of inverter is too small



check power of inverter and motor 

OPE



fly wheel inertia is too big



reduce fly wheel

COM

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

ENGINEERING CENTER

Trouble shooting Guide (Draft)

BERLIN

Page:

33/ 43

Date:

Nov. 8, 02

The current of one motor phase is zero. The message is displayed when the error is occurring four times Possible reason What to do check motor wiring, connectors and SW contacts  • the motor wiring is disconnected WIR (between inverter and motor) check power of inverter and motor   power of inverter is too high • OPE (current Mag Len



faulty floor will displayed in Error  Logging

LRN : Mag Len Var 



DEF

What to do use magnet with the right length

DEF

Length of used magnets is varied.

Possible reason •

What to do use magnet with the right length

Length of magnet is too long (maximum 450 mm)

Possible reason •

OPE

Length of magnet is too short (minimum 170 mm)

Possible reason •

see Error Logging ( )

faulty floor will displayed in Error  Logging



What to do use magnets with the same length

DEF

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Trouble shooting Guide (Draft)

BERLIN

faulty floor will displayed in Error  Logging

LRN : > Floor Dist

GAA21000CJ_TS1

Page:

34/ 43

Date:

Nov. 8, 02

Distance between 2 door zones is too short (minimum 170 mm)

Possible reason •

No.:

Vintage: 01 / 1

ENGINEERING CENTER

LRN : < Floor Dist

Part:

What to do 

check distance

MEA

The run time at contract speed between 2 landings is more then 52 seconds.

Possible reason •

Floor distance is too large.



What to do Check floor distance, install intermediate landing if  necessary



The positive edges of LV were not read correctly.



see error 'MLS: LV trig err' 

LRN : Too many LV

MEA

It will be count more floors at learn run then adjusted by SVT (Top Floor).

Possible reason • 

MEA

parameter TOP FLOOR  is incorrect

What to do 

Check parameter 'TOP FLOOR'  (M-3-1-goon).

Encoder adjustment has been aborted by a shutdown. Sub-code for further information: Press or Sub-code with possible reason What to do e=1 Check the parameter for motor type  wrong motor type • Measure the stator resistance of the motor with Multime ter and compare with your duty and speed 630kg @ 1,0m/s with motor 502  RS = 1,65 Ω 630kg @ 1,6m/s with motor 500  RS = 0,72 Ω 1000kg @ 1,0m/s with motor 503  RS = 0,95 Ω 1000kg @ 1,6m/s with motor 501  RS = 0,40 Ω Note: measuring between 2 motor phases: double R S value e=2  Change MCBIII • MCBIII is defect e=3 e=4 No encoder pulses detected  Check the electrical connection from encoder to MCBIII • Check the encoder, replace the encoder if it is defect  e=5 Change MCBIII  • No movement of motor shaft  Sticky brake lining

PAR

ADJ: EncAdj err 

e=6 e=7 e = 10 e = 11 e = 12

PAR

DEF

MEA

BRA



SW: invalid software state



For engineering only

OPE



Wrong motor type parameter 



Change the parameter 'Motor Type' 

PAR



No movement of motor shaft



Sticky brake lining

BRA



Safety chain opened during adjustment Adjustment aborted regarding other error  UIB / DIB released during adjustment in ERO mode



Check the safety chain parts and wiring



Check the errors with same run number 



Check UIB and DIB:

• •

ADJ: Auto-Encadj For information only

Drive performs automatic encoder adjustment (e.g. after manual rescue operation (MRO) during power-OFF)

SAF

OPE

SIG

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

8

Part:

Page:

35/ 43

Date:

Nov. 8, 02

DCSS5 related failures Peak output current greater than 7 A. If this event occurs 3 times within 120 sec, the DCSS switches into locked mode. Possible reason What to do

Inverter Prot

• •

Inverter is defect Motor is defect



check the inverter 



Check the motor windings (about 60 … 70 a motor with 100 W)

DEF

Ω/winding

for 

DEF

Motor current was for 10 sec higher than setup limit. If this event occurs 3 times within 120 sec, the DCSS switches to lock mode. Possible reason What to do

Motor Protect



Wrong motor selected



Motor is defect



Check the parameter setup for motor type: 3-2-5



Check the motor windings (about 60 … 70 a motor with 100 W)

Ω/winding

PAR

for 

Reduced pulses from encoder are measured. DCSS switches into INI mode. This error does not mean, that the error comes from the encoder itself. Please Encoder Err  follow the steps explained below. If the door does not work correctly then replace the encoder  Possible reason What to do When occurring many times:  The door mechanic is shortly • Start open/close door command and check the position blocked, e. g. disturbance caused by Monitor the door status: 3-1-1 (Position: …. mm) a passenger  When occurring occasionally:  Start the continuous run: 3-4-2 and check the position Monitor the door status: 3-1-1 (Position: …. mm) Check the wiring and the connection  • Encoder wiring or connection • •

Bad fixation of the encoder  One or two tracks of the encoder are damaged

 

Check the fixation Replace the encoder 

DEF

OPE

OPE

WIR OPE DEF

Indicates that the check sequence for the discrete interface failed three times. DCSS is set into locked mode Possible reason What to do

3wireComFail



the communication failed



Start the check sequence : 3-2-4

COM

DCSS out of order, serious event occurred. DCSS is de-energized and does not react on commands Possible reason What to do Unlock DCSS performimg power down – power up se Motor Protect event, or  quence or SVTOOL key-sequence ‘shift 5’  InverterProt event, or  OPE ( s ee the above giv en detailed information   ) 3wireComFail event

System Locked

• • •

 A problem could occur if the memory is full during a maintenance cycle. After each maintenance cycle time the event logging is to be deleted. Possible reason What to do  delete logging to free memory Event logging memory full MEA

Logging Full



OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

No.:

Trouble shooting Guide (Draft)

Page:

36/ 43

Date:

Nov. 8, 02

9 GLOSSARY 1LS 1LV 1TH 2LS 2LV 2TH  ACC  ADC  ADJ  ALB  ATT BAT BOT FL BRA BRB BS BS1 BS2 BY CAL CAN CB CCBL CCTL CDL CHC CHCS CHK CLR COM CON SPE CRE SPE CRP CSP-2 DBD DBP DCL DCP DCS DCSS5 DDO DDP DDSR DEC DEF DEMERC DFC DIR DIS DIST DLY DOB DOL DRV DS

= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =

GAA21000CJ_TS1

Vintage: 01 / 1

ENGINEERING CENTER BERLIN

Part:

Normal Terminal Slowdown Limit Switch for the bottom floor   Door zone recognition for down run Thermal contact 1 Normal Terminal Slowdown Limit Switch for the top floor   Door zone recognition for up run Thermal contact 2 Acceleration Analog to Digital converter  Adjustment Alarm button ATTendend service Battery Bottom floor   Brake Brake release button Brake switch Brake switch 1 Brake switch 2 BY-Relay Calibration Controller Area Network Car button Car Call to Bottom Landing Car Call to Top Landing Car Link Cancel hall calls Cancel hall call switch Check Car Light Relay Communication Contract speed Creep speed Creep Car sill protection (light beam gate) Drive brake disconect Door bypass Door close limit signal Delayed car protection Door check sequence Door Control Subsystem 5 Disable door operation Delayed drive protection (run timer) Disable door switch relay Deceleration Defective Disable Emergency Exit Contact Relay Door fully closed contact direction Indicator for start/stop relevelling up Distance Delay Door open button Door open limit Drive Door switch

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Trouble shooting Guide (Draft)

BERLIN = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =

No.:

GAA21000CJ_TS1

Vintage: 01 / 1

ENGINEERING CENTER

DTC DTO DW DZ DZI E&I EEC EFO EFS ENC ENG EPO ERO ES FCM FR GRP HB HDL HTS HWY I/O ICU INIT INP INS INS SPE INV ISC LED LNS LRN LS LST LV LWB MC MCBIII MCLS MCS MEA MISS MLS MOT MRL MRO NAV NDG NOM NOM SPE NOR NURF OCB OCSS OLD OP OPN OS

Part:

Door Time protection Close Door Time protection Open Door wiring (landing door contact) Door zone Door zone indicator for lamp Emergency and inspection Emergency exit contact Emergency fireman operation Emergency fireman service Encoder   Engineering Emergency power operation Electrical Recall Operation Emergency stop Field Component Manual Fast run Group Hall button Hall Link Hall temperature sensor   Hoistway Input/output Inter communication unit initialization input Inspection mode Inspection speed inverter   Independent service contact Light Emitting Diode Load non stop Learn run Limit switch lost Levelling Load weighing board Motion command Motion control board Machine room car light switch Modular Control System measurement Missing Motion logic state Motor   Machine room less Manual rescue operation Not available Nudging Nominal Nominal speed Normal mode Emergency power test Overload circuit breaker   Operational command subsystem Overload device Operation Open Over speed

Page:

37/ 43

Date:

Nov. 8, 02

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Trouble shooting Guide (Draft)

BERLIN = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =

No.:

GAA21000CJ_TS1

Vintage: 01 / 1

ENGINEERING CENTER

PAR PCB PDB PDD PDS PES POW PROF PROT PRS PSI RDY REB REL SPE REM RMP DWN RRB RS RSL RTB SAF SDI SIG SKL SPBC SPE SR SVT SW SYS TCBC TCI TES THB TOC TOCI TOP FL UDLS UIS VDC WIR

Part:

Parameter   Printed Circuit Board Power drive board Partition door device Partition door switch Pit emergency stop switch Power   Profile Protection Position Reference System Power supply interface ready Remote enabling button Relevelling speed Remote Elevator Monitoring Ramp down Remote resetting button Remote Station Remote Serial link Remote tripping button safety Speed direction indicator   signal Car light disconnecting switch Service panel board with Can Speed Slow run Service tool Switch System Traction Control Board Top of car inspection Top of car emergency stop switch Thermo contact Top of car   Top of car inspection Top floor   Up Down final Limit Switch Indicator for start/stop relevelling down Voltage DC Wiring

Page:

38/ 43

Date:

Nov. 8, 02

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

Page:

39/ 43

Date:

Nov. 8, 02

10 Reports for feedback 10.1

Elevator status

Name:

______________________

Location:

______________________  

Date/Time:

______________________

Unit No.:

______________________ 

TCBC Software version and release date

MCBIII Software version and release date

SPBC Software version and release date

DCSS5 Software version and release date

Date: ______________  Version: G_____________ 

Date: ______________  Version: G_____________ 

Date: ______________  Version: G_____________ 

Date: ______________  Version: G_____________ 

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

ENGINEERING CENTER

Part: No.:

GAA21000CJ_TS1

Vintage: 01 / 1

Trouble shooting Guide (Draft)

BERLIN

Page:

40/ 43

Date:

Nov. 8, 02

10.2 Event logging list to be filled out TCBC event logging

MCBIII event logging

DCSS5 event logging

SVT M-1-2-1 (Last event / time related)

SVT M-2-2-1 (Last event after Run)

SVT M-3-2-1-2 (Last Run / time related)

c

t

p





























































OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

No.:

GAA21000CJ_TS1

Vintage: 01 / 1

ENGINEERING CENTER

Trouble shooting Guide (Draft)

BERLIN

10.3

Part:

Page:

41/ 43

Date:

Nov. 8, 02

Parameters related to MCBIII

Contract (M - 3 - 1) SVT-Display Con Spe[0.01m/s] Con Nmot [rpm] Motor type Sys Inert[g*m^2] Encodertype LoadW type 2LV avail. DDP [s] TOP FLOOR BOTTOM FLOOR FLOORS IN 1LS MCB operat. BrakeSWtype Motor Dir [0/1]

Start / Stop (M - 3 - 4): Default 160 611 501 2700 4 3 0 20 1 0 1 0 3 0

Current value

Default 30 160 2 6 80 80

Current value

SVT-Display Mot Fnom [0.1Hz] Mot Vnom [V] Mot Inom [A] Mot Nnom [rpm]

Current value

Default 509 **** *) **** *) 611

Current value

Eng-Ctrl (M - 3 - 5 - 2): SVT-Display SpC FNr [0.1Hz] SpC FN0 [0.1Hz]

Default 50 50

Current value

Eng - MotEqC (M - 3 - 5 - 3):

Vane (M - 3 - 3): SVT-Display LV DLY UP [mm] LV DLY DOW N [mm] 1LS DLY [mm] 2LS DLY [mm] T_creep[10ms]

Default 10 80 70 30 30 1000 47 80 100

Eng-Motor (M - 3 - 5 - 1):

Profile (M - 3 - 2): SVT-Display INS SPE[0.01m/s] NOM SPE[0.01m/s] REL SPE[0.01m/s] CRE SPE[0.01m/s]  ACC [0.01m/s^2] DEC [0.01m/s^2]

SVT-Display PROF DLY [10ms] RMP DW N T2[10ms] DRP BK DLY[10ms] EL HLT PER[10ms] DEMAG PER [10ms] FULL LOAD [kg] BALANCE [%] LNS threshold[%]  ALWcomp Corr [%]

Default 80 80 50 50 40

Current value

SVT-Display MotEqc Rs [mOhm] MotEqcLsd[0.1mH] MotEqcLsq[0.1mH] MotEqc I0 [0.1A]

Default **** *) **** *) **** *) **** *)

Current value

*) These values are invisible after default setting

OTIS

FIELD COMPONENT MANUAL

Worldwide Engineering

Trouble shooting guide 1 (draft)

BERLIN

Note: All parameters are pre-adjusted by factory:

TCBC (SERVICE): M-1-3-1-07

Encoder SDI-Max SDI-Dir BRE-Max SPB-Temp

Default

Current value

13 30 0 10 60

TCBC (SYSTEM): M-1-3-1-01 SVT-Display TOP BOTTOM

Default

Current value

2 0

TCBC (DRIVE): M-1-3-1-04 SVT-Display SPEED

Page: Date:

Parameters related to TCBC

SVT-Display

No.:

Gxxxxxxxxxxxxx

Vintage: 01 / 1

ENGINEERING CENTER

10.4

Part:

Default 100

Current value

42/ 43