6.00sqm Minimum dimension of 2.00m 3.00sqm Minimum dimension of 1.50m 1.20sqm Minimum dimension of 0.90m
Follow NBC
MINIMUM AIR SPACE REQUIREMENTS Schools Offices and factories Habitable rooms MINIMUM CEILING HEIGHTS Ground floor Second floor Succeeding floors Mezzanine LIGHT AND VENTILATION Windows for rooms Windows for bathrooms Minimum dimension of court Min. width of court passageway
10% of floor area, but 1.00sqm minimum 5% of floor area, but 240 sq. mm. minimum 2.00m 1.20m
10% of floor area 5% of floor area 2.00m 1.20m
STAIRS Riser Tread
Minimum width Minimum headroom Maximum vertical distance between landings Handrail height
200mm maximum Slanted nosing preferred over Less than 10 OL:0.75m protruding nosing, 10-50 OL.: 0.90m provide 300mm-wide More than 50 OL:1.10m tactile strip at top and bottom of stairs. 2.00m 3.60m 800-900mm 250mm minimum
Existing stairs: 205mm max. New stairs: 100-180mm Existing stairs: 230mm min. New stairs: 280mm min. Existing stairs: 915mm New stairs, 0-49 OL: 915mm New stairs, 50-1999 OL: 1120mm New stairs, 2000 or more OL: 1420mm 2.00m 3.66m 760-865mm
RAMPS Maximum slope Maximum cross slope Minimum width Minimum landing length Distance between landings Handrail height CORRIDORS
1 in 12 No general requirements provided, only for ramps located in reviewing stands, grandstands and bleachers.
Follow NBC
1.20m 1.50m 6.00m (horizontal distance bet. landings) 700mm and 900mm
1 in 12 1 in 48 1120mm
760mm (vertical distance bet. landings) 760-865mm
250mm maximum 200mm minimum
600mm 2.00m 3.60m 800-1200mm
1.10m OCCUPANT LOADS (Area per person) Place of assembly Standing room Concentrated use Less concentrated use Educational Classrooms Shop, laboratories, vocational rooms Dry nurseries Conference rooms, exhibit rooms, gyms Healthcare Sleeping departments In-patient treatment Hospitals, sanitaria Nursing homes Children's nurseries Residential Dwellings Hotels, apartments, dormitories Mercantile Street floor or basement used for sale Upper floors used for sale Floors not used for sale (office, storage, etc.) Drinking establishments Commercial kitchens FIREWALL EXTENSIONS Above roof From outermost edges (walls) Under eaves EXITS Number of exits required (based on occupant load) Minimum width of exits Maximum travel distance to exit, no sprinkler Maximum travel distance to exit, with sprinkler
501-999 OL: 3 exits 10 or more OL: 2 exits 1000 or more OL: 4 exits 915mm Additional note regarding exits:
0-500 OL: 2 exits
Minimum width of exit door
900mm 800mm (for all doors)
Minimum height of exit door
2.00m 2.00m (For all doors)
Change in floor level at doors Maximum length of dead ends Place of assembly Educational Healthcare Detention/correctional Residential (hotels/dormitories) Residential (apartment buildings) Business Business, with NFPA 13 sprinkler system Industrial ELEVATORS
Various elevator requirements
50mm
In apartments or condomimiums 5 storeys or Inside dimensions of higher, at least 1 passenger car: 1.10m wide x elevator shall be kept on 241.40m deep hour constant service.
Maximum 4 cars per hoistway
0-9 OL: 1 exit
BP 220 specifically refers to Section 3.1007 of PD 1185 (the old Fire Code) for the exit requirements. This is included in BP 220 as Annex 1 on page 53.
13mm
Provide turnabout 6.00m space within 3.50m of any dead end
Minimum 600mm-deep pit
For rowhouse: 300mm For rowhouse: 300mm For rowhouse: 300mm
6.10m 6.00m 6.00m 6.00m 6.00m Not allowed 6.00m 15.00m 15.50m
Required for healthcare occupancies two storeys or higher.
Maximum travel distance from building Provide at least one exit per elevator lobby. entrance: 30.00m
Required for multi-family dwellings and condominiums 6 storeys of higher. Follow standards in NBC and BP 344.