Cobas E411 Sell Sheet

August 10, 2022 | Author: Anonymous | Category: N/A
Share Embed Donate


Short Description

Download Cobas E411 Sell Sheet...

Description

 

cobas e 411

analyzer 

take your lab to the next level  

 

cobas e 411 rack analyzer

cobas e 411 disk analyzer 

• •

Up to 86 tests/hour Clot and liquid level detection



System memory memory up to 2,00 2,000 0 results (samples and QC) that can be downloaded to a USB drive Automatic sample dilution upon request Windows XP-based control unit Individual and cumulative QC Preprogrammable calibrators and controls

• • • •

 

System specifications Feature System  Types of modu les les   System components  components  System interfaces  interfaces   Throughp ut ut   Number of reagent channels  channels   Programmable test parameters  parameters  Sample material  material  Sample input/output  input/output 

Sample volume  volume  Sample clot detection  detection  Sample barcode types  types  Control unit  unit  Calibrator/QC input  input  Calibration methods  methods  QC methods  methods  Data storage capacity  capacity 

Electrical requirements  requirements   Water/Wast e requir ements ements   Operating conditions  conditions 

Physical dimensions  dimensions 

 Weight    Weight

cobas e 411 analyzer   Fully automated, immunoassay analyzer for random access processing of ECL-based immunoassays ( cobas cobas e system e system format) • Optional System Table (cabinet); Optional • cobas e 411 e 411 disk analyzer System Table Extension (for printer) • cobas e 411 rack analyzer  Self contained bench top analyzer comprising an analytical unit and a customized user interface RS232 serial interface, bidirectional Up to 86 tests/hour  18 channels (reagent slots) for maximum of 18 tests N/A, programming-by-loading (PBT) concept, application data are transferred without operator intervention from the 2D barcode of the reagent pack (RP) into the instrument database Serum/plasma, urine, others • Disk Model: 30 positions for samples, calibrators and controls • Rack Model: 15 racks with 5 s amples each (= 75 samples in/out) • STAT STAT port: STAT STAT samples are processed with priority 10 – 50 μl Standard (pressure sensor) Code 128; Codabar (NW 7); Interleaved 2 of 5; Code 39 Microsoft® Windows® XP-based panel PC cobas e system-specic e system-specic barcoded CalSet vials on disk or racks Lot calibration (L-cal); Reagent Pack (RP) calibration (R-Cal) • Preventive QC after calibration of the • Individual QC and cumulative QC stand-by cobas e packs • Up to 100 controls pre-programmable • The memory contains data les necessary for the analyzer • QC Data File: Capacity up to 100 controls • Operating Parameter Parameter Data File: Up to and software to work together: 305 reagent applications • Reagent Data File: Up to 3 00 reagent packs • Up to 20 operator IDs • Sample Data File: Up to 2000 test records (for samples and controls) • Calibration Data File: Up to 160 calibrators calibrators • 230/110 Volts AC; 1,000 kVA (disk), 1,250 kVA (rack) • Frequency: 50 Hz or 60 Hz +/- 0.5% • Water: Bacteria free, de-ionized water supply, resistance of < 10 μS/cm • Liquid waste: Onboard waste container (4 liter), direct d rain optional • Ambient temperature: 18 to 32°C • Ambient humidity: 20 to 80% RH (without condensation) • Heat Output: 2,879 kJ/hr (analyzer unit) • Noise Output: 60 dBA (stand-by), 63 dBA (operation avg.) • Width (disk/r ack): 120 cm / 170 cm 47 47.2 .2 in / 67 in • Depth (disk/rack): 73 cm / 95 cm 28.7 in / 37.4 in • Height: 80 cm / 3 1.4 in (closed top cover) 109 cm / 43 in (opened top cover) • Disk: 180 kg / 397 lbs • Rack: 250 kg / 551 lbs

 

For more information, contact your Roche representative, call 1-800-852-8766 (option 7) or visit MyLabOnline.com. COBAS, COBAS C, COBAS E, LIFE NEEDS ANSWERS and MYLABONLINE are trademarks of Roche. MICROSOFT and WINDOWS are trademarks of Microsoft Corporation. © 2011 Roche Diagnostics. All rights reserved. 467-51037-1011 Roche Diagnostics 91 9115 15 Hague Road Indianapolis, IN 46256 MyLabOnline.com

View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF