Cameron Willis Self-Contained Emergency Shutdown Systems Reliable ESD Protection from the Wellhead to the Flowline
Cameron Willis Self-Contained Emergency Shutdown Systems
C
ameron Willis Self-Contained Emergency Shutdown
Or, if a fire occurs, the eutectic on the fusible plug melts
(ESD) Systems are used to hydraulically actuate gate
and the system automatically closes the valve and shuts in the
valves in remote locations. As the name
well. The system can also be operated in manual mode where
implies, these systems are totally self-contained and operate as ESD to automatically shut-in production in an emergency situation. Such systems
simple operation of a needle valve opens or closes the valve. Cameron Willis Self-Contained ESD Systems are available in 1-13/16” through 7” nominal
are ideal for use in on production well-
valve sizes and work-
heads or pipelines in remote locations
ing pressures up to
such as deserts, rain forests, arctic envi-
15,000 psi. Two ver-
ronments, jungles or any area where
sions are available, a
supervision is minimal or no additional
single pump and a
power source is available. Cameron Willis Self-Contained ESD Systems feature reliable, field-proven Cameron
double pump type which can be used when control of a master
Willis Saf-T-Gard™ hydraulic actuators mounted on
valve and subsurface safety valve (SSV) is required from
Cameron FLS gate valves. The Cameron Willis con-
one control box. Options include actuator-mounted or
trol system contains the sensors and hydraulic power
stand-mounted installation, enclosed panel or non-enclosed
source necessary to close the valve when an abnor-
panel, anti-theft shroud, panel-mounted or field-mounted
mal condition detected. For example, when
pressure sensors, electric position indicators and first-
the system is in automatic mode and flowline
out indicators. In addition, fusible plugs are available
pressure increases above or below the pres-
in temperature ranges 160°F, 212°F and 283° F. Solar
sure sensors “high” or “low” settings, the system automatically
powered pneumatic and solar powered hydraulic systems are also available.
closes the valve and shuts in the well.
Features and Benefits • System incorporates reliable, field-proven Cameron FLS gate valves, Cameron Willis Saf-T-Gard actuators and control panel from a single source. • Automatic control for master valves and subsurface safety valves provides safety in remote locations. • Self-contained power source is ideal for remote areas, wells without power, or sites with minimal supervision. • Available in single-and double-pump configurations to control a single gate valve or a gate valve and SSV. • Closed loop hydraulic circuitry ensures contaminantfree, long lasting supply of operating fluid. • Field-proven in extreme warm and cold environments.
• High/low pressure sensors provide flowline pressure monitoring to preset values. • Hydraulic accumulator accommodates temperature induced volume changes of the fluid contained in the closed circuit. • Fusible plug ensures shutdown in case of fire. • All components housed in secure stainless steel enclosure which meets the requirements for operation in hazardous locations without the need to purge the box. • Control panel can be mounted to the actuator or to a nearby stand to accommodate a variety of field situations.
Self-Contained SSV and SCSSV Control Systems
Self-Contained SSV Control System
Operating Procedure
Standard Arrangement
Place (K-1) the hydraulic dump valve in bypass, by turning the handle in the bypass position. Hand pump (B-1) to
L-1 Fusible Plug
6T
the required actuator operating pressure. This pressure can be seen on pressure gauge (E-1). When the flowline pressure is
ESD Pull to Shut In
between the low (F-1) ad the high (G-1) pressure sensor set
N-1
Set @ 150 PSI
G -1
F -1 D-1
J -1
points, the 100 regulated pressure from (C-1), which can be
Set @ 100 PSI
Set @ 5,000 psi P-1
seen on pressure gauge (D-1) will flow through the low sen-
H -1
C -1
K-1
PSL
Flowline 6T Sense
900 PSI Pre-Charge
A-1
PSH
N2
M -1
E-1 SSV
sor (G-1) and high sensor (F-1) allowing the 100 psi to hold
6T
B-1
(K-1) hydraulic dump valve closed. Now take (K-1) out of Material List
bypass by turning the handle to the in-service position. The
the reservoir, closing the surface safety valve (SSV).
Suction Strainer Hand Pump Regulator Pressure Gauge, 0-200 psi E. Pressure Gauge, 0-6000 psi
Self -Contained SSV and SCSSV 5000 psi Control System
Self -Contained SSV and SCSSV 10,000 psi Control System
Standard Arrangement
Standard Arrangement
system is now in service. If an ESD, fire, or PSHL occurs, the pilot pressure from (K-1) dump valve will be removed, allowing (K-1) to dump the fluid from the actuator back into
H-1
G-1
F. G. H. J. K.
High Pressure Sensor Low Pressure Sensor Relief Valve ESD Valve 2 Way N.O. Dump Valve with Manual Override
F-1
L. Hydraulic Fusible Plug M. 5000 psi Accumulator N. Filler/Breather P. Relief Valve
H-1
Set @ 150 psi
ESD Pull to Shut In
A. B. C. D.
G-1
F-1
Set @ 150 psi
ESD Pull to Shut In
D-1
D-1
N-1 J-1
N-1
PSL
Set @ 100 psi Set @ 5,000 psi A-1
J-1
PSH Flowline 6T Sense
C-1
L-1
P-1
6T
K-1
900 psi Pre-Charge
N2
M-1
Fusible Plug
Set @ 100 psi A-1 A-2
SSV
Q-1
900 psi Pre-Charge
N2
M-2
Flowline 6T Sense
E-2 B-1
SCSSV
6T
K-1
900 psi Pre-Charge
G. H. J. K.
Low Pressure Sensor Relief Valve ESD Valve 2 Way N.O. Dump Valve with Manual Override L. Hydraulic Fusible Plug
M-1
Fusible Plug
E-1 SSV 6T
Set @ 10,000 psi
K-2
Q-1
900 psi Pre-Charge
N2
M-2
E-2 SCSSV 4T
Material List Suction Strainer Hand Pump Regulator Pressure Gauge, 0-200 psi E. Pressure Gauge, 0-6000 psi F. High Pressure Sensor
N2
S-1
4T
A. B. C. D
L-1
P-1
P-2
S-1 K-2
PSH
C-1
B-1
6T
P-2 Set @ 5,000 psi
Set @ 5,000 psi
E-1
R-1 B-1
PSL
Material List M. 5000 psi Accumulator N. Filler/Breather P. Relief Valve Q. Flow Control R. 3-Way Valve S. Low Pressure Accumulator
A. B. C. D.
Suction Strainer Hand Pump Regulator Pressure Gauge, 0-200 psi E. Pressure Gauge, 0-6000 psi F. High Pressure Sensor
G. H. J. K.
Low Pressure Sensor Relief Valve ESD Valve 2 Way N.O. Dump Valve with Manual Override L. Hydraulic Fusible Plug
M. 5000 psi Accumulator N. Filler/Breather P. Relief Valve Q. Flow Control R. 10,000 psi Hand Pump S. Low Pressure Accumulator
SSV Control Panel The control system for a typical Cameron Willis Self-
necessary output pressure to the actuator. Closed loop
Contained ESD System is incorporated into a 316 stain-
hydraulic circuitry for maintenance of hydraulic pressure.
less steel enclosure with a mounting bracket. Connectors
Hydraulic accumulator with 900 psi nitrogen pre-charge
are mounted on the side of the panel for ease of installa-
for thermal expansion. Relief valves on both high pres-
tion in virtually any field layout.
sure and low pressure hydraulic circuits. ESD valve for
A typical controls system enclosure includes the following components: Hydraulic hand pump to provide the
emergency shutdown. Pressure gauges to monitor output pressures for the high pressure and low pressure circuit.
SSV Control Panel Features 100 60 40
4000
160
20 0
3000 2000
140
200
0
1
psi
Schematic Reference
1
D-1
6000
2 PLOT PRESSURE
Item
5000
1000
180
psi
SSV PRESSURE
Name Pilot Pressure
IN SERVICE
3 PLOT PRESSURE
4
PLOT PRESSURE
5
PILOT MODE SELECTOR
6
ESO PULL TO CLOSE
2
E-1
SSV Pressure
3
K-1
Turn Clockwise to Override Pilots
4
K-1
Turn Counterclockwise for Normal Operation
5
Q-1
Pilot Mode Sector In-Service/Test
6
J-1
ESD Pull to Close
7
G-1
Low Pilot
8
F-1
High Pilot
9
C-1
Pilot Supply Regulator
10
B-1
Hand Pump
HAND PUMP
10 LOW PILOT
7
HIGH PILOT
PILOT SUPPLY REGULATOR
8
9
Typical Cameron-Willis ESD Control System
Fusible Plug
EMERGENCY SHUTDOWN
ESD Station
Control Panel
Actuator
Bonnet Sense Line
Needle Valve
Wing Valve
Flow Line
Cameron-Willis ESD System wit Pole-Mounted Control Panel Controlling Single SSV
The Cameron Willis self-powered control system provides a hydraulic power to remote areas.
One Source. One Choice. Cameron Willis.
The Cameron-Willis ESD System Brings Customers the Cameron Single Source Advantage From the wellhead to the control panel, from installation to field service, Cameron Willis Self-Contained ESD Systems bring the full support of Cameron’s vast product knowledge and technical expertise. Each system starts with Cameron’s highly successful S and IC Wellhead Systems. Next, Cameron offers a choice of popular gate valves including the rugged FLS Gate Valve. The addition of Cameron-Willis H2 Production Chokes and a full line of Saf-T3000 4000 2000
5000
1000 0
100
180
SSV RE SSU PRE
200 20 0
Se
rvic
Ou to fS erv ice
psi
T PLO RE SSU PRE
IN
E VIC SER
ESOCLOSE L TO PUL
e
D
ES
Gard™ Actuators com-
160
60 40
In
6000
psi
140
D HAN P PUM
pletes the Christmas tree
E T MOD OR PILO ECT SEL T PLO RE SSU PRE T PLO RE SSU PRE
PLY T SUP TOR PILO ULA REG
H HIG T PILO
LOWT PILO
assembly. The addition of the Cameron Willis ESD Control System completes the all-Cameron ESD system with reliable components from just one source. Additional benefits come from Cameron’s CAMSERV™ Aftermarket Services Program that provides a full range of installation, maintenance and repair services any time, anywhere in the world. No one can match the ability of Cameron to provide such complete solutions for such a wide variety of applications.
Western Hemisphere Cameron
Cameron Willis
PO Box 1212
10810 N.W. Freeway
Houston, Texas 77251-1212
Houston, Texas 77092
Tel 713 939 2211
Tel 713 683 4600
Fax 713 939 2620
Fax 713 683 4350
Eastern Hemisphere Cooper Cameron (U.K.) Ltd.
Cameron Willis
5 Mondial Way
Aghafad, Longford
Harlington
Republic of Ireland
Hayes, UB3 5AR
Hayes, UB3 5AR
Tel
Tel
011 44 181 990 1800
Fax 011 44 181 990 1888
011 353 43 45301
Fax 011 353 43 41560
Asia Pacific/Middle East Cooper Cameron (Singapore) Pte, Ltd.
Cameron Willis
No. 2 Gul Circle, Jurong Industrial Est
5003 93rd Street
Locked Bag Service No. 3
Edmonton, Alberta T6E 559
Jurong Town Post Office
Tel 65 8613355
Singapore
Fax 65 8616197
Republic of Singapore Tel 65 8613355 Fax 65 8616197
Visit our website at www.camerondiv.com
©Cooper Cameron Corporation, Cameron Division, Printed in USA 12/00, OP/5M, WR10168/TC1440
View more...
Comments