BW-700 Manual English 2010-1

December 7, 2022 | Author: Anonymous | Category: N/A
Share Embed Donate


Short Description

Download BW-700 Manual English 2010-1...

Description

 

   Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk

 

Bridge Watch Alarm System BW-700 Manual

 

BW-700 is produced in accordance with international and Danish laws for ”one man bridge” operation e.g. IMO resolution A.830. BW-700 has been designed for mounting on a DIN rail in the power cabinet or flush mounting. The purpose of the bridge watch alarm system is to ensure the continuous monitoring of the bridge operator’s fitness during "one man bridge" operation.

BW-700 Manual English 2010-1

Page 1 of 14

 

   Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk

 

Technical specifications: Main supply:

12 or 24 V 12 V ( Min. 11V / Max. 15V ) 24 volt ( Min. 16V / Max. 29V )

Power consumption:

Max. 0,4 A. The power supply must be secured against overcurrent externally. Max. 2.0 A

Power failure alarm:

Mount a suitable relay and connect to General alarm. Se wiring diagram page 6.

Consumption:

Max. 10.0 Watt

Dimensions:

Width 105 mm / Height 86 mm / Depth 58 mm.

Operating Temperature:

-10 up to +65 degrees C.

 Adjustable timers:

Qty.: 2 pcs. Timer 1: adjustable from 3 up to 12 minutes. Timer 2: adjustable from 60 up to 180 sec. (internal)

Relay contacts:

Qty.: 4 pcs.  All relay contacts are galvanic separated separated from the BW-700 unit and from each other. Relay contacts: Max. 250V AC, 5A.

Protection:

IP54.

Operation:

Key disconnector: 3 positions. The key can be taken out in all positions.

Dimmer function:

Adjustment of the light intensity from max. to –80%.  Adjustment of both internal and external light. Supply to external light: 12V Max. 200mA.

12 V output:

To movement detectors. Max 200 mA.

Cable requirements:

Marine proof cable min. 0,5mm² and maximum 1mm².

BW-700 Manual English 2010-1

Page 2 of 14

 

   Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk

 

Cable connections:  connections: 

Terminal 1:

Plus 24 V supply

Terminal 2:

Minus ( GND )

Terminal 3:

Plus 12 V supply

Terminal 4:

Minus ( GND )

Terminal 5:

Plus 12 V max. 200mA. To movement detector Disconnects in case of overload.

Terminal 6:

Reset in. Terminal 4-6 closed by resetting the timer.

Terminal 7:

Emergency Terminal 4-7button. must be closed for 2 sec. to activate the emergency function.

Terminal 8:

Plus 12 V max. 200mA To background light, is adjusted by the DIMMER button

Terminal 9:

Minus ( GND )

Terminal 10:

Supply to auto pilot. When active terminal 9-10 must be closed.

Terminal 11 – 12:

Relay contact. Togler 5 sec. before timer has ran out

Terminal 13 – 14:

Relay contact. Closed by alarm 1.

Terminal 15 – 16:

Relay contact. Closed by alarm 2.

Terminal 17 – 18:

Relay contact. Closed by alarm 3.

BW-700 Manual English 2010-1

Page 3 of 14

 

   Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk

 

Operating instructions: The Bridge Watch can only be activated and deactivated by use of a key. Therefore, only authorised personnel personnel (usually the captain) can decide if the bridge watch alarm should be active or not. The key function has 3 setting modes: The 3 modes are: ON ON (the  (the BW is active all the time), Off  (the  (the BW is not active) and Auto Auto   (in this mode the BW is only active when the ship’s autopilot is on). When the BW-700 is active, the built-in timer must be reset, before the preset timer has run out. The reset of the timer can be done in two different ways: manually by activating a reset button or by ensuring a constant movement (activity) sensed by the movement detector on the bridge. The time is set on the t he adjusting button Timer  before  before the  the BW is activated. The preset time cannot cannot be  be changed as long as the BW-700 is active. When the timer is 15 sec. from running out, a warning is activated. The warning can be a small alarm buzzer or a light signal depending on what is connected. This gives the captain time to reset the timer before the alarm is activated. st

If the captain of the ship has not reset the timer within 15 seconds the 1  of the 3 alarms will be activated. Alarm 1: This alarm is placed on the bridge and is meant to ensure a weakening of e.g. a drowsy ships master. The alarm can be switched off by resetting the timer. If the timer is not reset after 15 seconds the alarm switches to alarm 2. 2. Both alarm 1 and 2 is now active. Alarm 2:  2:  This alarm is placed where the back-up officer / captain is presumed to be. Now the alarm can only be switched off by using a key.  key.   However, the alarm on the bridge will be silent when the timer is reset. Alarm 2 stays active until the key is used to switch it off. If the alarm is not switched off and there is still no activity on the bridge after 60180 seconds the alarm 3, 3, now alarm 1, 2 and 3 is activated. The timer can be set from 60180 seconds during installation, installation, to give time to the back-up officer to react on the alarm. Alarm 3: 3: This alarm is placed in the crew area. The alarm can only be switched off by using a key.  key.   However, the alarm on the bridge becomes silent when the timer is reset in order to avoid stressed personnel. Alarm 2 and 3 remains active until the key is used to switch it off. Emergency calls: BW-700 also has an option for connection of emergency calls. This will be in the form of a push button. When activated for 2 seconds the alarm will automatically go to alarm 2 and subsequently to alarm 3 if no action is taken. Using this function the ships master is able to call for assistance if needed. The alarm can only be switched off by using a key. key. However,  However, the alarm on the bridge becomes silent when the timer is reset in order to avoid stressed personnel. Alarm 2 and 3 remains active until the key is used to switch it off.

BW-700 Manual English 2010-1

Page 4 of 14

 

   Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk

 

PRINCIPLE DIAGRAM   BW-700  Alarm 3 output

 Alarm 2 output

 Alarm 1 output

 Alarm for timer

18

Int. Adjust.

Relay

1-3 min.

17 16

Timer  4 Relay

15 14

Timer  3 Relay

13 12 11

CE

Timer  2 Relay

   t   r   o  o    l    i    t   p  c   e   o   t    t   u  e    d    A

 Auto pilot signal input10 Minus ( GND ) output 9 Plus 2-12 V output to background light

8

Dimmer  20-100% Ext. just.

Emergency input 7 Reset input Plus 12 V movement detector 

6

Ext. Adjust. 3-15 min. Timer  1

Minus ( GND ) input

 Auto

5 Power  adjust.

3 2 24 >12

Plus 24 V input

1 BW-700 Manual English 2010-1

On

Key

Minus ( GND ) output 4 Plus 12 V input

  y   c   r   n   t   o   e   c   g   e   r   t   e   e    d   m    E

volt reg.

  Page 5 of 14

 

   Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk

  r

tef a

. sr :

MA R G AI D G NI RI W

2 mr al A

.

a er a w er

0 0 7W B

. c

-

mr la al ar e n e G

:

3 mr al A

c

´s

ni at p a C

.

e s 5 1 d te a

mr al a s

vi

1 e th

t c

A

mr al a . d n 2 e ht

vit

2B A

r

tef a

c

A

e c n at si s s A

e c n at si s s A

)

)

2B A

t.

.

e s 0 8 10 6 d et a

c

.

ter a u q

2 0 7 : m et I (

e g di

e ht n e h w d et a

r

b ot

2 0 7 : m et :

1 mr al A

I(

e c n at si s s A

e g di r

b ot

.

e g di r B c

vit

A

.t

u o n ar

2B A

s

a h r e mit

)

2 0 7 : m et I(

e g di r

b ot

,

e vi tc

a n e h W

)

3 0 7 : m et I(

0 0 7W B

t c

d e s lo

at n oc e ht c is

to u A ff

O n O

.

V 2 1 .

V 4 2 ,

rm la a l ar e n e G

r

v

si

o mr al a l a u .

mr la a oi d u a

.)

r

mr la a er uli af ew o P

BW-700 Manual English 2010-1

ly

O N yla er

p p us dr a d n at tso N(

e s u F

    p       m      A      2

R -1B R

)

(I

3 0 7: m et

A N R -1B R

)

4 0 7 :m et I(

 

Page 6 of 14

 

   Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk

 

125 mm.

On

O ff

Aut o

125 mm.

135 mm.

115 mm.

110 mm.

BW-700 Manual English 2010-1

Page 7 of 14

 

   Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk

 

The picture below shows the BW-700 mounted in a mounting box no. 710. Dimensions: Height = 185 mm. Width = 145 mm. Depth = 85 mm.

BW-700 Manual English 2010-1

Page 8 of 14

 

   Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk

 

AB-2:

 AB-2 is designed desig ned for use together with BW-700. B W-700. AB-2 will sound an alarm when the t he timer has expired. It sounds a powerfull tone from the 4 loudspeakers and the red warnings light flashes. AB-2 can be preset to 5 different warning pitches during the installation. To avoid disturbance when the alarm goes off, AB-2 is constructed to start with low volume, and rising to high volume within seconds. The maximum volume can be set between 75 and 90 DB.

Voltage: Power compsumption: Compsumption: Dimensions: Temerature range: Protection:

12 to 24 volt DC. internal. stab. to 12 volt. Max 0,15 Amp. Max 3,6 Watt. W:50mm H:75mm D:30mm -10 to +55 degrees. IP 54.

Terminal 1: Terminal 2:

Ground  Alarm plus.

Volume Sound switch H-0 H-H L-0 L-L H-L

Assistance to bridge

H= high tone L=low tone 0= no tone Principle diagram 1 2

BW-700 Manual English 2010-1

Page 9 of 14

 

   Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk

 

RB-1R:

RB-1RNA is designed for use together with BW-700 as reset button with light warning. The unit has background light and this is regulated by the dimmer function on BW-700. 5 seconds before the timer has ran out, the alarm and the background light starts flashing.

Power consumption: Consumption: Dimensions: Temperature range: Protection:

2-12 volt DC for background light 12 to 24 volt DC. For warning light. Max 0,04 Amp. Max 1,0 Watt. W:50mm H:50mm D:30mm -10 to +55 degrees. IP 54.

Terminal 1:

Background light ( plus )

Terminal 2: Terminal 3: Terminal 4:

Minus ( GND ) Reset contact Warning light ( plus )

Mains supply:

Principle diagram 1 2 3 4

 

BW-700 Manual English 2010-1

Page 10 of 14

 

   Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk

 

RB-1RNA:

RB-1RNA is designed for use together with BW-700 as reset button with sound and light warning. RB-1RNA also has an emergency function. The unit has background light and this is regulated by the dimmer function on BW-700. 5 seconds before the timer has ran the alarmfunction and thepress background light starts To activate theout, emergency the reset button forflashing. more than 2 seconds.  After 2 seconds the sound warning will sound shortly to notify that the emergency function is activated. Mains supply: Power consumption: Consumption : Dimensions: Temperature range: Protection: Terminal Terminal Terminal Terminal Terminal

1: 2: 3: 4: 5:

2-12 volt DC for background light 12 to 24 volt DC. For warning light. Max 0,04 Amp. Max 1,0 Watt. W:50mm H:50mm D:30mm -10 to +55 degrees. IP 54. Background light ( plus ) Minus ( GND ) Reset contact Emergency contact Warning light ( plus )

1

Principle diagram 2 3 4 5

 

BW-700 Manual English 2010-1

Page 11 of 14

 

   Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk

  Motion sensor 1. FEATURES

Input Voltage: 9 Voltage: 9 to 16 VDC Current Drain: About Drain: About 28 mA @ 12 VDC Size (H x Weight: 109 Weight:  109 W xg D): 117 D): (3.85  117 oz) x 65 w/oxbracket, 47 mm. 124 g (4.4 oz) with bracket. PIR SECTION Detector: Low Detector:  Low noise dual-element dual-element pyroelectric sensor Tripping Indication: LED Indication: LED flashes green for up to 5 seconds Motion Event Verification Counter: Selectable, Counter: Selectable, 1 or 2 events No. of Beams: 36 Beams: 36 in two layers (curtain beams in bottom layer) Max. Coverage: 12 x 12 m (40 x 40 ft) / 90° field of view Vertical Adjustment: FAR and NEAR, by sliding the circuit board along a two-position scale. MW SECTION Oscillator: Microstrip Oscillator:  Microstrip DRO-stabilized Doppler module Frequency: 10.525 Frequency:  10.525 GHz (U.S.A. only) or 2.45 GHz (Europe) Detection Range: Adjustable Range: Adjustable from 25% to 100% (3 m to 12 m) Tripping Indication: LED Indication: LED glows green for up to 5 seconds Alarm Indication: LED Indication: LED glows red for 1.3 to 5 seconds if both detectors trip MOUNTING  MOUNTING  Height:: Up to 3.6 m (12 ft) Height Room Size: 8 -12 m (24 - 40 ft) in the “FAR” position; 2 - 8 m (6 - 24 ft) in the NEAR position.  position.  Bracket Adjustment: Adjustment: 20° downward, 20° left and right. Installation Options: Options: Surface or corner (without bracket); surface or ceiling (with bracket) ENVIRONMENTAL   ENVIRONMENTAL RFI Protection: >30 V/m up to 1000 MHz. Operating Temperatures: -10°C Temperatures: -10°C to 50°C (14°F to 122°F). Storage Temperatures: Temperatures: -20°C  -20°C to 60°C (-4°F to 140°F).  140°F). 

Mounting with Swivel Bracket A. Remove the the front PCB cover. and put it temporarily aside. B. Remove C. Punch out the large knockout in the round bulge at the top part of the base.

BW-700 Manual English 2010-1

Page 12 of 14

 

   Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk

 

Visual Indications The dual color LED is used to signal various alarm and trouble messages as shown in Table 1 below: Table 1. Interpreting the Visual Indications Visual Indication None  None  Steady green (5 s) Flashing green Steady red (5 s) Flashing red and green (alternately)

Significance No detection MW walk-test detection PIR walk-test detection  Alarm: MW + PIR detection detection - Trouble or masking is being detected by the self test circuitry - Initial warm-up routine (stops 60 seconds after power up).

Notes:

During walk testing, the green light glows steadily (MW detection) or flashes (PIR detection), depending on which one of the two detectors discovered the movement first. Upon subsequent discovery discovery of the t he movement by the other detector, the green light goes off and the red light glows (alarm).  If the LED maintains alternate red and green flashing beyond the warm-up period, a malfunction or masking has been diagnosed. Replace the unit without delay. The DIP switch mode selector is mounted on the unit’s PC board (see Figure 5). It controls four functions as demons- trated in Figure 12 and as detailed in Table 2.  2. 

Installation hints: Prevent direct sunlight from reaching the detector

Keep wiring away from electrical power cables

Do not install behind partitions

Do not aim at heat sources

Mount on solid, stable surfaces

Do not expose to air drafts

BW-700 Manual English 2010-1

Do not install outdoors

Page 13 of 14

 

   Amager Strandvej 124 2300 Copenhagen Denmark Tel. +45 3286 0525 Fax: +45 3258 1330 e-mail: [email protected] www.unielec.dk

  Troubleshooting guide:

Step: Problem: 1 No reset from motion sensor.

2

No lights in BW-700

3

No alarm on bridge and  Alarm LED 2 and 3 are always on

Description: Check voltage on Reset 1 input (BW-700 connector pin 6). Low voltage when LED in motion sensor is red. If constant low, remove the wire to the motion sensor and check again. Check external fuses Check DC power on terminal 1-4 (12/24Vdc) Check the cable connections Check DC power on terminal 6 on BW-700 (0V/low, only when reset button is pushed or a movement is detected) Movement detector: When the red LED is on, a low pulse is sent from terminal “R” If constantly low:

Possible Causes: Standard mounting bracket not used and screws behind the PCB is shortcutting the sensor. Remove the screws and use the standard mounting bracket. BW-700 has no power

Installation failure Movement detectors defective Reset button defective

1) off) Turn the the BW-700 BW-700 off off (key in position position 2) Remove all wires from terminal terminal 6 3) Set the alarm to 3 minutes minutes and set the key in position on 4) Check that “alarm “alarm 1” 1” starts after 3 minutes (BW-700 is then ok) 5) Turn the BW-700 off 6) Mount the wire from one reset button to terminal 6 7) Set the key in position on 8) Check that “alarm “alarm 1” 1” starts after 3 minutes 9) Check that you can reset reset the alarm by pushing the reset button (reset

4

button 1 is ok) 10) Turn the BW-700 off 11) Mount Mount the wire from one movement detector to terminal 6 12) Set Set the key in position on and don’t move 13) Check Check that “alarm 1” starts after 3 minutes 14) Check Check that you can reset the alarm by walking around (movement detector is ok) 15) Check additional reset buttons and movement detectors by the same procedure as above No alarm 1-3 Check the cable connections. Cable failure and the LED’s Check 12Vdc power at the terminals on the  Alarm units defective defective for alarm 1-3 alarm units. are on

BW-700 Manual English 2010-1

Page 14 of 14