BSC Command

February 10, 2023 | Author: Anonymous | Category: N/A
Share Embed Donate


Short Description

Download BSC Command...

Description

 

BSC COMMAND

 

Content › GSM MO structure › BSC Command

Ericsson Internal | 2014-01-15 | Page 2

 

MANAGED OBJECTS  An MO is a logical representation representation of of hardware units and software in the BTS. ›Two types of MO exist: SO and AO ›SO = Service Object › AO  AO = Application Application Object Object are related to SO

Ericsson Internal | 2014-01-15 | Page 3

 

Managed Object on DXU and TRU

DXU

SO

CF

CF IS

AO

IS

CON

TF

DP0

DP1

DP2

DP3

TF CON DP

TRU

SO

TRXC AO

RX

TX

TS0

TS1

TS2

TS3

TS4

TS5

TS6

TS7

TS0

TS1

TS2

TS3

TS4

TS5

TS6

TS7

TDMA Frame Ericsson Internal | 2014-01-15 | Page 4

TRXC

RX TX TS

 

Object model

TG

CF DP

MCTR

IS

TF

CON

TRXC

4

16

RX RUS

DUG

TX

TS 8

12

Object model vs HW view, RBS 6000

Ericsson Internal | 2014-01-15 | Page 5

 

MANAGED OBJECTS • Transceiver Group (TG) • Central Funcon (CF) • Digital Path (DP) • Interface Switch (IS) • Timing Funcon (TF) • Concentrator (CON) • Transceiver Controller (TRX) • Transmier (TX) • Receiver (RX) • Time Slots (TS) • MCTR (RBS6000RU (RBS6000RUS)Mul S)Mul carrier transceiver

Ericsson Internal | 2014-01-15 | Page 6

 

MANAGED OBJECTS › TG ----- RXOTG-tg › CF ----- RXOCF-tg › IS ----- RXOIS-tg › CON ----- RXOCON-tg › TF ----- RXOTF-tg › TRX ----- RXOTRX-tg-ltrxc RXOTRX-tg-ltrxc › TX › RX

----- RXOTX-tg-l RXOTX-tg-ltrxc trxc ----- RXORX-tg-lt RXORX-tg-ltrxc rxc

› TS

----- RXOTS-tg-l RXOTS-tg-ltrxc-lts trxc-lts

Ericsson Internal | 2014-01-15 | Page 7

 

MML Syntax

General command syntax

Ericsson Internal | 2014-01-15 | Page 8

 

MML Structure

RX RL

Structure of the command code

Ericsson Internal | 2014-01-15 | Page 9

 

MO status › UNDEF › DEF › COM › PREOPER › OPER › NOOPER › FAIL MO

STATE BLSTATE BLO BLA LMO BTS CONF

RXOTS-116-0-1 OPER

0000 0000 0000 ENA ENA

RXOTS-116-0-2 OPER

0000 0000 0000 ENA ENA

RXOTS-116-0-3 OPER

0000 0000 0000 ENA ENA

Ericsson Internal | 2014-01-15 | Page 10

 

Basic command ›mml

 //enter GSM command environment 

›RXBLI:MO=RXOTG-116,subord,force;

 //block site

›RXESE:MO=RXOTG-116,subord; ›RXESI:MO=RXOTG-116,subord;

 //deblock site

›RXBLE:MO=RXOTG-116,subord;



Upgrade ›cpfls  //Print the contens of the disk  ›RXMSC:MO=RXOTG-116,SWVER=TDEVG7X082; ›RXPLI:MO=RXOTG-116;

 //running the upgrade upgrade patch

›RXPLP:MO=RXOTG-116;

 //check the upgrade status

  Ericsson Internal | 2014-01-15 | Page 11

 

■ Define TG ›RXMOI:MO=RXOTG-0,COMB=FLT/HYB,RSITE=GUOTONGP,   SWVER=B3991R004F; ›RXMOC:MO=RXOTG-0, FHOP=BB/SY, HFSEXT=On; ›RXMOP:MO=RXOTG-0; ›RXMSP:MOTY=RXOTG ; ›■ Connect TG to Cell › RXTCI:MO=RXOTG-0,CELL=SHD1020,CHGR=0;

Ericsson Internal | 2014-01-15 | Page 12

Ericsson Internal | 2014 01 15 | Page 12

 

■ Define CF ›RXMOI:MO=RXOCF-0,TEI=62,SIG=CONC/UNCONC; ■

Define IS

›RXMOI:MO=RXOIS-0; ■

Define TF ›RXMOI:MO=RXOTF-0, TFMODE=M/S/SA; ›RXMOP:MO=RXOTF-0;

Ericsson Internal | 2014 01 15 | Page 13

 

■Define TRX ›RXMOI:MO=RXOTRX-0-0, RXMOI:MO=RXOTRX-0-0,TEI=0,DCP1=178, TEI=0,DCP1=178, DCP2=179&186,   SIG=UNCONC; ›RXMOI:MO=RXOTRX-0-1,TEI=1,DCP1=187,DCP2=188&195, SIG=UNCONC; ›RXMOI:MO=RXOTRX-0-2,TEI=2,DCP1=196,DCP2=197&204, SIG=UNCONC; ›RXMOP:MO=RXOTRX-2-1

 

Ericsson Internal | 2014-01-15 | Page 14

 

Connect TRX to cell ›  RXMOC:MO=RXOTRX-0-0,CELL=SHD1020; ›  RXMOC:MO=RXOTRX-0-1,CELL=SHD1020; ›  RXMOC:MO=RXOTRX-0-2,CELL=SHD1020;

Ericsson Internal | 2014-01-15 | Page 15

 



Define TX

›  RXMOI:MO=RXOTX-0-0,B RXMOI:MO=RXOTX-0-0,BAND=GSM1800,MPWR=45; AND=GSM1800,MPWR=45; ›  RXMOI:MO=RXOTX-0-1,B RXMOI:MO=RXOTX-0-1,BAND=GSM1800,MPWR=45; AND=GSM1800,MPWR=45; ›  RXMOI:MO=RXOTX-0-2,B RXMOI:MO=RXOTX-0-2,BAND=GSM1800,MPWR=45; AND=GSM1800,MPWR=45;

Connect TX to cell ›  RXMOC:MO=RXOTX-0-0, CELL=SHD1020; ›  RXMOC:MO=RXOTX-0-1, CELL=SHD1020; ›  RXMOC:MO=RXOTX-0-2, CELL=SHD1020;

Ericsson Internal | 2014-01-15 | Page 16

 

■ Define RX

RXMOI:MO=RXORX-0-0,BAND=GSM1800,RXD=AB; ››    RXMOI:MO=RXORX-0-1,BAND=GSM1800,RXD=AB; ›   RXMOI:MO=RXORX-0-2,BAND=GSM1800,RXD=AB; ›   RXMOP:MO=RXORX-2-1&RXOTX-2-1;

Ericsson Internal | 2014-01-15 | Page 17

 

› ■ Define TS ›  RXMOI:MO=RXOTS-0-0-0&&-7; ›   RXMOI:MO=RXOTS-0-1-0&&-7; ›   RXMOI:MO=RXOTS-0-2-0&&-7;

Ericsson Internal | 2014-01-15 | Page 18

 

cell related paramEters ■ Define cell ›RLDEI:CELL=B10B791,CSYSTYPE=GSM900;   CSYSTYPE : Cell system type, GSM900 、 GSM1800 ›RLDEC:CELL=B10B791,CGI=460-00-21411-11791,BSIC=72,  

BCCHNO=75,AGBLK=1,MFRMS=4,BCCHTYPE=NCOMB,

 

FNOFFSET=0,XRANGE=NO;

 CGI: Cell global identity

CGI = MCC + MNC + LAC + CI 

 BSIC: Base station identity code BSIC = NCC + BCC   BCCHNO: Absolute radio frequency channel number for for Broadcast Control Channel (BCCH)

 

Ericsson Internal | 2014-01-15 | Page 19

 

■ RLDGI:CELL=B10B791,CHGR=1;    //define channel group

■ RLCFI:CELL=B10B791,CHGR=1,DCHNO=65;

 

 //Configuration Frequency Frequency

■ RLBDC:CELL=B10B791,NUMREQEGPRSBPC=4,CHGR=1;  

 //  NUMREQEGPRSBPC:  NUMREQEGPRSBPC: Number of required EGPRS BPCs ( Enhanced General Packet Radio Service Basic Physical Channels )

Ericsson Internal | 2014-01-15 | Page 20

 

■ RLCCC:CELL=B10B791,CHGR=0,SDCCH=1,CBCH=NO,TN=2;

 

 //SDCCH: Stand Alone Dedicated Control Channel 

■ RLCHC:CELL=B10B791,CHGR=0,HOP=ON,HSN=63; ■ RLCHC:CELL=B10B791,CHGR=0,HOP=ON ; ■ RLCHC:CELL=B10B791,CHGR=0,HOP=OFF;

Ericsson Internal | 2014-01-15 | Page 21

 

■ RLCPC:CELL=B10B791,BSPWRB=45,MSTXPWR=31,BSPWRT=45;  

 // MSTXPWR: the max TX power 

■ RLSTP:CELL=B10B791;

 //check the cell status 

›RLSTC:CELL=B10B791,STATUS=active; ›RLSTC:CELL=B10B791,STATUS=halted;

■ RLDEP:CELL=B10B791;

 //deb cell   //bl cell 

Ericsson Internal | 2014-01-15 | Page 22

 

Summary MO : ›RXMSP:MO= ; ›RXMSP:MOTY= ; › RXMOP:MO= ; ›RXMOP:MOTY= ; › RXCDP : MO=RXOTG- ; › RXTCP : MOTY=RXOTG,CELL= ; ›RXTCP: MO=RXOTG- ; › RXAPP : MO=RXOTG- ;

Ericsson Internal | 2014-01-15 | Page 23

 

Summary Cell: ›RLDEP : CELL= ; › RLCFP: CELL= ; › RLCCP: CELL= ; SDCCH ›RLSTP: CELL= ; ( ACTIVE or HALTED ) ›RLCHP: CELL= ; › RLCRP: CELL= ; › RLNRP: CELL= ,CELLR=ALL; ›RLMFP : CELL= ; › RLSLP: CELL= ;

Ericsson Internal | 2014-01-15 | Page 24