November 19, 2022 | Author: Anonymous | Category: N/A
Download Brochure - Attom - Smoothair In-Row Cooling PDF...
SmoothAir SmoothAi r Modul Modular ar Precis Precision ion Cooling
Specialist Support + Flexible Customization+
Modular Precision Cooling for Smart, Reliable and Green MDC Solution
ATTOM SmoothAir SmoothA ir Modul Modular ar Preci Precision sion Cooli Cooling ng Designed and optimized op timized for micro data center center,, and modular data center solutions. 1.0kW-40.9kW Row Mount, Rack Mount, Top Mount and Wall Mount
Customize with Expert. A simple, flexible, expandable, and intelligent modular data center solution is one of the keys to distributed edge computing success. SmoothAir precision cooling system is a dedicated product specially designed and optimized for modular micro data center solutions to remove heat from IT equipments and create an ideal environment for mission critical assets. SmoothAir precision cooling products designed and optimized with mechanical, air flow management, and smart control to fulfill the overall requirements of modular data center solution such as integration, modularity, and intelligent portal. The standardized mechanical design matches common server cabinet size and structure. Built in monitoring port supporting integration into high level management systems to view, and control the cooling equipments. Designed for fully enclosed and cold/hot aisle applications. The cooling system runs at highly efficient level which consumes much less power comparing to traditional room cooling solutions.
Application Schematic SmoothAir Smoot hAir Precision Precision Cooling Cooling for Micro Data Center Use SmoothAir Precision cooling to build micro data center which is low noise, dust proof and energy efficient.
Server Rack
Cooling Unit Hot Air
Servers
Cold Air
SmoothAir Smoot hAir Precision Precision Cooling Cooling for Mod Modular ular Data C Cente enterr ATTOM precision cooling is ideal for cold/hot containment modular data center solution with its target cooling, cold/hot air path, and highly efficient technology.
Server Racks Cold Air Containment
Hot Air
Cooling Units
Cold Air
Key Features Seamless MDC Integration > Designed for rack mount, row mount, wall mount or top mount to be seamlessly integrated into server racks. Customizable to match closed aisle or open aisle modular data center solution. > Standard monitoring port to be integrated into higher level DCIM system easily. > Front door and structure customizable tto o be built into MDC to keep uniform design style.
Reliability > Developed by professional precision cooling team following proven R&D process and industry standards. > Designed with recognized component components s and thorough testing to enhance reliability level. > Full protection and alarm control system for quick diagnose and reactivate the unit.
Green & Efficient > Cooling capacity and air flow automatically modulated to match the dynamic IT output. > Dedicated cooling close to IT heating source saves more than 30% energy comparing to traditional room cooling solution.
Serviceability > Unit level and components level modularity supports quick replacement and reduce MTTR. > Swappable fans allow system to remain operational if a replacement is required. Easy electric box service operation with the slide-out design. > Easy to change G4 air filter guarantees the cleanliness of MDC. > Quick installation with coupled piping connection.
Monitoring Management > Intelligent control comes with monitoring por portt and with standard protocol make it easy to real time view, control and adjust cooling units remotely. > Full alarm and notification supports combined cooling and power logic . > Team-work mode and backup mode between multiple units.
Smooth Smoo thAi Airr Row Mou Mount nt Air cooled, row mount, split type, ty pe, ideal for micro data center, integrated modular data center solutions. 5.6kW-25.1kW 300mm Width
5
1
2
7
2
3
3 4 6
Dynamically modulated cooling capacity with inverter compressor maintains temperature within envelop and prevent compressor from cycling during low heat load period. Air flow modulates modulates with EC fans to match IT equipment requirements. Each fan module is easy to change with quick couple connections. connections. Precision cooling controller monitors and protects unit constantly. Easy to be integrated into BMS to display, control and manage the system. R410A green refrigerant is
1
8
4
highly efficient and no ODP.
5
Copper piping adopts quick connections and supports bottom and top connection connections. s.
6
Easy to change G4 air filter and sealed doors help to build a clean and quiet MDC.
7
Slide drawer style electric box makes service easier.
8
Optional with condensate pump, leaking kit and long
5
piping kit for diverse applications.
Smoo thAi Airr Row Mou Mount nt Smooth Air cooled, row mount, split type, ty pe, ideal for modular data center and container data center solutions. 40.9kW 600mm Width 5
1
4
2 7
3
3
6
2
1
8
5
Dynamically modulated cooling capacity with inverter compressor maintains temperature within envelop and prevent compressor from cycling during low heat load period. Air flow modulates modulates wit with h EC fans to match IT equipment requirements. Each fan module is easy to change with quick couple connections. Precision cooling controller monitors and protects unit constantly. Easy to be integrated into BMS to display, control and manage the system.
4
R410A green refrigerant is highly efficient and no ODP.
5
Copper piping supports bottom and top connections.
6
Easy to change G4 air filter and sealed doors help to build a clean and quiet MDC.
7
Slide drawer style electric box makes service easier.
8
Optional with condensate pump, leaking kit and long piping kit for diverse applications.
Tech chni nica call Data Data-- Sm Smoo ooth thAi Airr Ro Row w Mou Mount nt DX Te Smooth SmoothAir Air DX Type Row Mount Mount Indoor Unit
S-005RA
S-007RA
S-012RA
S-017RA
S-020RA
S-025RA
S-040RA
Total Cooling-kW
5.6
7.6
12.8
17.6
21.2
25.1
40.9
SHR-%
100
100
100
100
100
100
100
Air Volume-m3/h
2000
2250
2400
4500
4920
5000
8000
Mount Type
Row
Row
Row
Row
Row
Row
Row
Cooling Type
DX
DX
DX
DX
DX
DX
DX
Height-mm
2000(42U)
2000(42U)
2000(42U)
2000(42U)
2000(42U)
2000(42U)
2000(42U)
Depth-mm
1100
1100
1100
1100
1100
1100
1100
Width-mm
300
300
300
300
300
300
600
Weight-kg
210
213
233
253
258
260
360
Reheat-kW
3.0
3.0
3.0
6.0
6.0
6.0
6.0
Hum.(optional)-kg/h
1.5
1.5
1.5
1.5
1.5
1.5
3
220V/50-60Hz /1Ph
220V/50-60Hz /1Ph
380V/50-60Hz /3Ph
380V/50-60Hz /3Ph
380V/50-60Hz /3Ph
380V/50-60Hz /3Ph
380V/50-60Hz /3Ph
28.2
37.3
20.9
27.0
26.7
27.9
37.7
Power Input1) FLA-A1)with heating FLA-A1)with hum.
33.3
42.4
22.0
32.1
31.8
33.0
47.9
208V/50-60Hz
208V/50-60Hz
460V/60Hz
460V/60Hz
460V/60Hz
460V/60Hz
460V/60Hz
/2Ph
/2Ph
/3Ph
/3Ph
/3Ph
/3Ph
/3Ph
28.2
37.3
17.2
22.3
22.1
23.1
31.1
33.3
42.4
18.2
26.5
26.3
27.3
39.6
Power Input3)
-
-
208V/50-60Hz /3Ph
208V/50-60Hz /3Ph
208V/50-60Hz /3Ph
208V/50-60Hz /3Ph
208V/50-60Hz /3Ph
FLA-A3)with heating
-
-
39.2
49.4
48.8
51.1
68.9
FLA-A3)with hum.
-
-
42.3
52.5
52.0
54.2
75.1
KSF08AN
KSF12AN
KSF18AN
KSF24AN
KSF32AN
KSF38AN
KSF52AN
Height-mm
790
790
1240
689
689
695
695
Depth-mm
420
420
420
990
990
990
1273
Width-mm
800
800
800
1407
1407
1407
1607
-
-
-
450
450
450
450
28
40
67
105
110
120
150
220V/50-60Hz /1Ph
220V/50-60Hz /1Ph
220V/50-60Hz /1Ph
380V/50-60Hz /3Ph
380V/50-60Hz /3Ph
380V/50-60Hz /3Ph
380V/50-60Hz /3Ph
Power Input2) FLA-A2)with heating FLA-A2)with hum.
Outdoor Unit
Leg Height-mm Weight-kg Power Input1) FLA-A1)
1.5
1.5
3.0
2.0
2.0
2.8
4.0
208V/50-60Hz /2Ph
208V/50-60Hz /2Ph
277V/50-60Hz /1Ph
460V/50-60Hz /3Ph
460V/50-60Hz /3Ph
460V/50-60Hz /3Ph
460V/50-60Hz /3Ph
1.5
1.5
2.4
1.7
1.7
2.4
3.3
Power Input3)
-
-
208V/50-60Hz /2Ph
380V/50-60Hz /3Ph
380V/50-60Hz /3Ph
380V/50-60Hz /3Ph
380V/50-60Hz /3Ph
FLA-A3)
-
-
3.0
2.0
2.0
2.8
4.0
Power Input2) FLA-A2)
Notes: 1. Air flow is based based upon upon maximu maximum m settin setting. g. Fan Fan modu modulat lates es per real real loads. loads. 2. Co Cool olin ing g Ca Capa paci city ty ba base sed d on 37℃ / 24%RH 24%RH return air and 35 ℃ outdoor temperature with the suggested condenser. 3. FLA of indoor unit includ includes es FLA FLA of outdoor outdoor unit. unit. No including including optiona optionall humidifier humidifier and heater. heater. 4. Options Options including including monitor monitoring ing card, card, low tem temperatu perature re kit, pipe extension extension kit, kit, dual dual power input, input, leaking leaking detection detection.. 5. 6. 7.
Sta tand ndar ard d unit unit work workss --1 15℃ and above outdoor temperature. Select low temperature kit to work -35℃ and above outdoor temperature. Custo Customi mized zed desig design n is ne nego goti tiabl able. e. Rights Rights reserv reserved ed to chang change e paramete parameters rs witho without ut prior prior notif notificat ication ion..
Smooth Smoo thAi Airr Row Mou Mount nt Chilled water, row mount, ideal for modular data center and container data center solutions. 28.9kW – 65.8kW 300mm / 600mm Width 1 5
Dynamically modulated cooling capacity with motorized ball valve maintains temperature within envelop and prevent water from cycling during low heat load period. Air flow modulates modulates wit with h EC
4
7
2
3
3
6
2
1
8
5
fans to match IT equipment requirements. Each fan module is easy to change with quick couple connections. Precision cooling controller monitors and protects unit constantly. Easy to be integrated into BMS to display, control and manage the system.
4
Touch type color display panel to easily view and control the units.
5
Copper piping supports bottom and top connections.
6
Easy to change G4 air filter and sealed doors help to build a clean and quiet MDC.
7
Slide drawer style electric box makes service easier.
8
Optional with condensate pump, leaking kit and dual power supply for diverse applications.
Te Tech chni nica call Data Data-- Sm Smoo ooth thAi Airr Ro Row w Mou Mount nt CW SmoothAir CW Type Row Mount SmoothAir Mount Model
S-025RC
S-045RC
S-065RC
Total Capacity –kW
28.9
46.0
65.8
SHR -%
100
100
100
Air Volume -m3/h
4800
9000
11400
Mount Type
Row
Row
Row
Height –mm
2000(42U)
2000(42U)
2000(42U)
Depth –mm
1100
1100
1100
Width –mm
300
600
600
Weight –kg
190
330
400
Reheat-kW
3.0
3.0
3.0
Hum.(optional)) -kg/h Hum.(optional
1.5
1.5
1.5
220V/50-60Hz/1Ph
380V/50-60Hz/3Ph
380V/50-60Hz/3Ph
FLA –A1)with heating
22.7
13.7
16.0
FLA –A1)with hum.
27.8
18.8
26.1
Power Input2)
208V/50-60Hz/2Ph
460V/50-60Hz/3Ph
460V/50-60Hz/3Ph
FLA –A FLA –A2)with hum.
22.7 27.8
11.3 15.5
13.2 21.5
Power Input3)
-
208V/50-60Hz/3Ph
208V/50-60Hz/3Ph
FLA –A3)with heating
-
25.1
29.2
FLA –A3)with hum.
-
28.1
35.5
Power Input1)
2)with heating
Notes: 1. Air flo flow w is based based upon upon maxim maximum um setti setting. ng. Fan modulat modulates es per real real load loads. s. 2. Co Cool olin ing g Ca Capa paci city ty ba base sed d on 37℃ / 24%RH 24%RH return air and 13℃ /18℃ water temperature. 3. FLA not inc includ luding ing optiona optionall humid humidifie ifierr and and h heat eater. er. 4. Option Optionss includin including g monitorin monitoring g car card, d, 3 way water water valve, valve, dual dual power input input,, leak leaking ing detection. detection. 5. Cu Custo stomi mized zed desig design n is ne negot gotia iabl ble. e. 6. Rights Rights re reserv served ed to chang change e paramet parameters ers wi witho thout ut prior prior notifi notificat cation ion..
Smoo Sm ooth thAi Airr Ra Rack ck Mo Moun untt Air cooled, rack mount, split type, suitable for micro data center, mini modular data center solutions. 3.9kW-12.0kW 4
5
7 1 2 8 6 3
1
Inverter compressor and EC fan works at high efficiency, maintains temperature within envelop and prevent compressor from cycling during low heat load period.
5
2
Standard rack mount structure fully compatible with server rack is flexible for future expansion.
6
3
Precision cooling controller monitors and protects unit constantly. Easy to be integrated into BMS to display, control and manage the system.
7
4
Slide drawer style electric box makes service easier.
8
Copper piping adopts quick connection and supports bottom and top connections.
Compressor locating in outdoor unit lowers the noise level then better suits customer expectation of mini data center application. application.
R410A green refrigerant is highly efficient and no ODP.
Front air outlet suitable for installation on flexible height in a rack.
Tech nica call Dat Data a - Sm Smoo ooth thAi Airr Ra Rack ck Mou Mount nt DX DX Techni SmoothAir SmoothA ir Rac Rack k Mount Mount DX DX Model
S-003KA
S-005KA
S-007KA
S-012KA
Total Capacity-kW
3.9
5.0
7.2
12.0
SHR -%
95
96
96
96
700 Rack
1800 Rack
2000 Rack
2400 Rack
Height –mm
266(6U)
355(8U)
445(10U)
533(12U)
Depth –mm
828
828
828
828
Width –mm
483
483
483
483
Weight –kg
31
43
52
70
Reheat(optional) –kW
1.2
1.2
2.4
2.4
Hum.(optional)) -kg/h Hum.(optional
-
-
-
-
220V/50-60Hz/1Ph
220V/50-60Hz/1Ph
220V/50-60Hz/1Ph
380V/50-60Hz/3Ph
13.9
15.2
21.6
18
20 2088-24 240V 0V/5 /500-60 60Hz Hz/2 /2Ph Ph
46 460V 0V/5 /500-60 60Hz Hz/3 /3Ph Ph
Air Volume -m3/h Mount Type
Power Input1) FLA –A1) Power Input2) FLA –A2)
20 2088-24 240V 0V/5 /500-60 60Hz Hz/2 /2Ph Ph 20 2088-24 240V 0V/5 /500-60 60Hz Hz/2 /2Ph Ph 13.9
15.2
21.6
14.9
Power Input3)
-
-
-
208V/50-60Hz/3Ph
FLA –A3)
-
-
-
32.9
Outdoor Unit
KSF06AC
KSF08AC
KSF12AC
KSF18AC
Height -mm
632
790
790
1240
Depth -mm
395
420
420
420
Width -mm
800
820
820
820
-
-
-
-
35
38
50
77
220V/5 V/50Hz-6 Hz-60 0Hz/1 Hz/1Ph Ph
22 220 0V/5 /50 0Hz-6 z-60Hz/1 Hz/1Ph Ph
22 220 0V/5 /50 0Hzz-6 60H 0Hz/ z/1 1Ph
380V/5 V/50Hz-6 Hz-60 0Hz/3 Hz/3Ph Ph
12.6
13.2
19.6
16
208-240V/50Hz60Hz/2Ph
208-240V/50Hz60Hz/2Ph
20 2088-24 240V 0V/5 /50H 0Hzz-60 60Hz Hz/2 /2Ph Ph
46 460V 0V/5 /500-60 60Hz Hz/3 /3Ph Ph
12.6
13.2
19.6
13.3
Power Input3)
-
-
-
208V/50-60Hz/3Ph
FLA –A3)
-
-
-
29.3
Leg Height -mm Weight -kg Power Input1) FLA –A1) Power Input2) FLA –A2)
Notes: 1. Air flow is based based upon upon maximu maximum m set settin ting. g. Fan Fan modu modulat lates es per real real loads. loads. 2. Co Cool olin ing g capa capaci city ty ba base sed d on 37℃ / 24%RH 24%RH return air and 35 ℃ outdoor temperature with the suggested condenser. 3. FLA of indoor unit includ includes es FLA FLA of outdoor outdoor unit. unit. . No including including optional optional hum humidifier idifier and heater. heater. 4. Options Options including including monitor monitoring ing card, card, low tem temperatu perature re kit, pipe extension extension kit, kit, dual dual power input, input, leaking leaking detection detection.. 5. Sta tand ndar ard d unit unit work workss --15 15℃ and above outdoor temperature. Select low temperature kit to work -35℃ and above 6. 7.
outdoor temperature. Custo Customi mized zed de desig sign n is ne nego gotia tiabl ble. e. The rrigh ightt reser reserved ved to to change change paramet parameters ers witho without ut prior prior notifi notificat cation ion..
Smoo Sm oothA thAir ir Top Mou Mount nt Air cooled, top mount, indoor and outdoor packaged, suitable for micro data center, center, mini modular data center solutions.
1.5kW – 3.5kW
1 6
2
4
3 5
1
2
3
Industry top brand compressor. Highly reliable and efficient. Precision cooling controller monitors and protects unit constantly. Easy to be integrated into BMS to display, control and manage the system. Compatible with standard rack size forms unified and integrated mdc solution.
4
5
6
Packaged installation,design serviceeasy andfor shipping.
Top mount means good air management of hot/cold stream and no occupying of IT space. Green refrigerant is highly efficient and no ODP.
Techni Tech nica call Da Datata- Sm Smoo ooth thAi Airr To Top p Mo Moun untt SmoothAir Smooth Air Top Mou Mount nt Unit
S-001TA
S-002TA
S-003TA
Total Cooling-kW
1.5
2.5
3.5
SHR-%
100
100
100
Air Volume-m3/h
500
800
1380
Mount Type
Top
Top
Top
Cooling Type
DX
DX
DX
Height-mm
390
390
390
Depth-mm
1100
1100
1100
Width-mm
600
600
600
Weight-kg
45
50
55
220V/50Hz/60Hz/1Ph
220V/50Hz/60Hz/1Ph
220V/50hz/60Hz/1Ph
3.5
5.5
6.5
208-240V/50Hz/60Hz/2Ph
208-240V/50Hz/60Hz/2Ph
208-240V/50Hz/60Hz/2Ph
3.5
5.5
6.5
Power Input1) FLA-A1) Power Input2) 2)
FLA-A
Notes: 1. Co Cool olin ing g capa capaci city ty ba base sed d on 37℃ / 24%RH 24%RH return air and 35℃ outdoor air. 2. Options Options inclu includin ding g monitor monitoring ing card card,, cond condens ensate ate evapora evaporatio tion n kit. 3. The The frequ frequen ency cy 50H 50Hzz or 60H 60Hzz is choi choicea ceabl ble e upon upon ord order. er. 4. Cu Cust stomi omized zed desig design n is ne nego goti tiab able. le. 5. The right right reserv reserved ed to chang change e paramete parameters rs witho without ut prior prior notif notificat ication ion..
SmoothA Smoo thAir ir Wal alll Mo Moun untt Air cooled, wall mount, indoor and outdoor packaged, suitable for micro data center, center, mini modular data center solutions.
5.5kW–21.2kW
1
Industry top brand compressor. Highly reliable and efficient.
4
2
Precision cooling controller monitors and protects unit constantly. Easy to be integrated into BMS to display, control and manage the system.
2
5
3
4
Adopts high high pressure/high air flow centrifugal blower suiting critical equipment cooling condition.
6
Packaged design easy for installation, service and shipping.
1 3
5
Wall mounting to side of cabinet no occupying of IT space.
6
Green refrigerant is highly efficient and no ODP.
Techni Tech nica call Da Datata- Sm Smoo ooth thAi Airr Wa Wall ll Mo Moun untt Smooth othAir Air Wal Walll Moun Mountt Smo Unit
S-005WA
S-007WA
S-012WA
S-017WA
S-020WA
Total Cooling-kW
5.5
7.5
12.5
17.5
21.2
SHR-%
100
100
100
100
100
Air Volume-m3/h
1850
2000
2400
3500
4000
Mount Type
Wall
Wall
Wall
Wall
Wall
Cooling Type
DX
DX
DX
DX
DX
Height-mm
1920
1920
2100
2100
2100
Depth-mm
650
650
650
650
650
Width-mm
900
900
1000
1000
1000
Weight-kg
180
230
285
320
355
220V/50Hz/60Hz/1Ph
220V/50Hz/60Hz/1Ph
380V/50Hz/60Hz/3Ph
380V/50Hz/60Hz/3P
380V/50Hz/60Hz/3P
15.6
17.6
16.0
19.5
27.5
208-240V/50Hz/60Hz/2Ph
208-240V/50Hz/60Hz/2Ph
460V/60Hz/3Ph
460V/60Hz/3Ph
460V/60Hz/3Ph
15.6
17.6
12.4
16.2
22.8
Power Input3)
-
-
-
-
-
FLA-A3)
-
-
-
-
-
Power Input1) FLA-A1) Power Input2) FLA-A2)
Notes: 1. Co Cool olin ing g Ca Capa paci city ty ba base sed d on 26℃ / 40%RH 40%RH return air and 35 ℃ outdoor air. 2. Option Optionss incl includi uding ng mo monit nitori oring ng card, card, conden condensate sate evapo evaporati ration on kit kit.. 3. The The frequ frequenc encyy 50Hz 50Hz or or 60Hz 60Hz is ccho hoic iceab eable le up upon on ord order. er. 4. The refrig refrigeran erantt R134a R134a is used used for the the ambient ambient tempera temperatur ture e up to 55C maxim maximum. um. 5. The 208V/6 208V/60Hz 0Hz/3P /3Ph h models models uti utiliz lize e inverte inverterr compres compressor sor.. 6. Custo Customi mized zed desig design n is ne negot gotia iabl ble. e. 7. The right rightss reserved reserved to change change param parameter eterss without without prior prior noti notifica ficatio tion. n.
w ill be totally We believe the world will connected. The connections are creating
intelligence and, a better future.
We design and deliver precision cooling products optimized for
edge data center application to accelerate connections and intelligence throughout throughout to the edges.
Contact Attom Technology 1450 NE Alex Way APT 299 Hillsboro, OR 97124, USA
Call us +86 755 2320 7291 Email us
[email protected] Visit us on web http://www.attom.tech
SA-BR-V2.3 Copyright © 2019 All Rights Reserved.