SOLTEQ®
Equipment for Engineering Education & Research
CONTINUOUS STIRRED TANK REACTOR MODEL: BP 100
HE Continuous Stirred Tank Reactor (Model: BP 100) has been designed to introduce students of Chemical Engineering on reactor and reaction behaviour. This type of reactor is one of the most important industrial reactors. The unit comes with all the ancillary equipment except analytical instrumentation for the measurement of the composition of feed and product mixtures.
T
The unit includes a reactor vessel of approximately 4 litres total capacity, and is equipped with a variable speed stirrer with digital display, inlet and outlet ports for the feed and product streams, sampling, temperature measurement and control. The reactant volume is adjustable by an overflow device. Two non-corroding feed storage vessels are supplied, together with chemically resistant pumps and flowmeters. A product collection vessel is also provided, thus allowing approximately 1 to 2 hours continuous operation.
The reactor comes with a cooling coil for maintaining the reaction temperature. A digital temperature controller is also provided on the front panel. Both exothermic and endothermic reactions can therefore be carried out at constant temperature up to approximately 80 oC. A conductivity meter is provided for the purpose of determining the extent of conversion. A gas feed line is included, complete with a gas sparging ring, a flowmeter and a flow regulating valve to facilitate gasliquid reactions: e.g., oxidation.
Equipment for Engineering Education & Research
EXPERIMENT CAPABILITIES ♦ ♦ ♦ ♦ ♦ ♦
Chemical kinetic studies Batch or continuous operations Effect of residence time Effect of temperature Mixing effects Heat transfer
SPECIFICATIONS Bench-mounted apparatus designed to demonstrate reaction behaviour, including homogeneous and gasliquid reactions, allowing 1 to 2 hours continuous operation. Integral heating and mains water cooling with connections to laboratory supplies. REACTOR: Material Total Volume Working Volume Cooling System Heating System
Gas Sparger Sample analysis
: 1 LPM : 240VAC/1-phase/50-60Hz.
FLOW CONTROL: Liquid Flowmeter : up to 500 ml/min; electronic Gas Flowmeter : up to 30 LPM; electronic Control valves : needle valves
INSTRUMENTATIONS: The unit is fitted with all necessary instruments for the measurements of reaction temperature, reactants flow rates, and conductivity.
OPTIONAL ITEMS
- EI DIGITAL INSTRUMENTATIONS : borosilicate glass; stainless steel top and bottom plate : 4L : 2 to 3.5 litre (adjustable) : cooling water through stainless steel cooling coil : 1.5 kW; immersion heater; Temperature Sensor; Temperature Controller : perforated stainless steel tube : sampling valves (analytical instruments are not included)
STIRRER SYSTEM: Motor Rating : 75 W (input); 55 W (output) Variable Speed : 50 to 2,000 rpm; with speed controller and LCD indicator Impellers : 2” dia.; stainless steel Electrical : 240VAC/1-phase/50-60Hz. FEED TANKS: Capacity Material
FEED PUMPS: Capacity Electrical
SOLTEQ
SOLTEQ®
i) 3 units of electronic flow meter with digital display ii) 1 unit of conductivity sensor with monitor iii) 1 unit of temperature sensor with digital display - DAS SOLDAS DATA ACQUISITION SYSTEM i) ii) iii) iv)
A PC with Pentium processor A signal conditioning unit A stand alone data acquisition modules A Windows based software ♦ Data Logging ♦ Signal Analysis ♦ Process Control ♦ Real-Time Display ♦ Tabulated Results ♦ Graph of Experimental Results
- CAL SOLCAL COMPUTER AIDED LEARNING SOFTWARE : 30 litre (cylindrical) : Stainless steel
PRODUCT TANKS: Capacity : 60 litre (rectangular) Material : Stainless steel
i) Interactive multimedia features ii) Graphical simulation iii) Experiment results samples iv) Full experiment manuals
OVERALL DIMENSIONS
♦ Electrical supply : 240VAC/1-phase/50-60Hz. ♦ Water supply : Laboratory mains supply with drainage points ♦ Working area : ventilated; approx. 10 m2 ♦ Chemicals : ethyl acetate and caustic soda are suggested ♦ Gas cylinder for optional gas-liquid reaction ♦ Analytical equipment
Height: 1.52 m Width: 1.22 m Depth: 0.91 m
SOLTEQ
REQUIREMENTS
MANUAL
The unit is supplied with Operating and Experiment Manuals in English giving full descriptions of the unit, summary of theory, experimental procedures and typical experimental results.
TYPICAL EXPERIMENT RESULTS
EXPER IM EN T A B A TC H R EA C TIO N
Conc. of Ethyl Acetate with NaOH
3 2.5 2 1.5 1 0.5 0 1
2
3
4
5
6
7
8
9
10
T ime (m in)
E X P E R IM E N T B P L O T (In C b /C a v s . t) 2 .5
In(Cb/Ca)
2 1 .5 1 0 .5
11
12
13
14
0 0
5
10
15
20
25
T im e (m in )
30
35
40
45
SOLTEQ®
Equipment for Engineering Education & Research
SOFTWARE & E-LEARNING Our range of teaching equipment can be complemented with our SOLDAS and SOLCAL software.
SOLDAS ® - Supervisory Control & Data Acquisition - Data Logging - Signal Analysis - Process Control - Real-Time Display - Tabulated Results - Graph of Experiment Results
SOLCAL® - Computer Aided Learning - Multimedia Features - Interactive - Graphic Simulation - Samples of Experiment Result - Full Experiment Manuals
Contact us for a catalog CD SOLUTION ENGINEERING SDN. BHD.
AGENT:
(Co. No. 174876-M) Sales Office : No.3, Jalan TPK 2/4, Taman Perindustrian Kinrara, 47100 Puchong, Selangor Darul Ehsan, Malaysia. Tel. No. : +(603) 80758000 Fax. No. : +(603) 80755784 R&D Office : G-2A, Incubator 3, Technology Park Malaysia, Bukit Jalil, 57000 Kuala Lumpur, Malaysia. Tel. No. : +(603) 8996 0023 Email :
[email protected] Web site : http//www.solution.com.my/
MSC- Status BUATAN MALAYSIA
Company