Basic Motor Vibration Troubleshooting Tips

May 3, 2018 | Author: rajuanthati | Category: Troubleshooting, Screw, Bearing (Mechanical), Machine (Mechanical), Electrical Engineering
Share Embed Donate


Short Description

Descripción: ECM WEB...

Description

Basic Motor Vibration Troubleshooting Tips

http://ecmweb.com/print/motors/basic-motor-vibration-troubleshooting-tips

print | print  | close

Electrical Construc Construction tion and Mai ntenan ntenance ce

Reed Hamm and Bryan Evans, TECO Westinghouse Westinghouse Tue, 2011-11-22 16:21

Because the causes c auses of machine ma chine vibration are so numerous, the underlying problem is often difficult to isolate. Most troubleshooting processes rely on advanced diagnostic techniques and result in the dismantling of the machinery to achieve a chieve a complete c omplete solution. solution. However, However, you can ca n perform the following following basic checks without expensive expensive equipment to determine natural frequency, ac tive foundations, foundations, and gross unbalance issues — all of   which can cause excessive excessive vibration vibration and should should be avoided avoided whene whenever ver possible. possible. Perform a Visual Check of the Machine Machine Foundation

The machine foundation plays a vital role in the vibration level of the installed equipment. A rigid and massive foundation (Photo (Photo 1) 1) is ideal, because it minimizes background vibration observed observed at the motor or other equipment. A massive foundation is less active, meaning it will limit the total movement of the system and thus the vibration level of the machine due to its own mass and stiffness. Although rigid and massive foundations are preferred, they are regrettably not the rule. In most instances, it’s not possible to use an ideal f oundation oundation due to space, cost, c ost, or some other variable. varia ble. More often than not, the installation will have a less-than-ideal foundation and correspon c orrespondingly dingly more-than-ideal vibration (Photo ( Photo 2). 2). If you suspect foundation is an issue, there are additional additional checks c hecks you can perform to confirm if this is the ca se. Checking the background vibration and foot  vibration levels, as well well as impact testing, testing, can all aid in deciding deciding whether whether a foundation foundation is the root cause of your problem. Test for an Act ive or Flexible Foundation Foundation Per NEMA Standard MG-1 (Motors and Generators), an active foundation allows excessive movement and transmission of external vibration to the machine while a rigid (non-flexible) foundation limits the vibration vibration at the feet — and does not allow excessive transmission of machine vibration into the surrounding structure. Use the following two tests to determine if an active and/or flexible foundation exists.

Basic Motor Vibration Troubleshooting Tips

http://ecmweb.com/print/motors/basic-motor-vibration-troubleshooting-tips

 Active foundation check — Take a measurement of the bac kground vibration level at the same location used to measure the machinery bearing housing vibration during operation. Then, perform a vibration test on the machinery bearing housings with all of the train components shut down. If the overall vibration levels you measure at the bearing housings while the equipment is not operating are 25% or higher than the respective operating vibration levels, then you’re dealing with an active foundation. This check can be somewhat subjective  because excessive operating vibration can mask a bad foundation — because the background vibration level may  not meet the 25% criteria but may still be excessive. In these instances, follow this general rule: If the overall  vibration level at the bearing housings exceed 0.030 in. per sec peak overall (with the equipment not operating), further investigation may be warranted.  Flexible foundation check — With the machine operating in any configuration, measure the overall vibration levels at the bearing housings as well as at the motor feet in as many axes as pra ctical. Compare the overall  vibration measured at each axis of the bearing housing to the overall vibration measured at each respective axis of the adjacent foot. If the overall levels measured at the foot are 25% or higher than those measured in the same axis on the adjacent bearing housing, then the foundation is considered to be flexible. As with background  vibration, the 25% criteria may not be accurate, depending on the levels observed during testing. Once again, the 0.030 in. per sec peak overall is a good rule of thumb to follow. Check the Machine Mounting How the machine is secured to the foundation is just as important as the foundation itself. Induction motors are typically provided with instruction books to help ensure the machine is secured in accordance with the manufacturer’s recommendations. Failure to follow these recommendations can result in vibration problems.  Bolting — One of the most basic items in the mounting of the motor are the bolts used to secure the motor to the foundation through the motor feet. Although simple in nature, these tend to be problematic. Ensure the bolts are sized in accordance with the manufacturer’s recommendations, and verify all of the foot mounting bolts are properly torqued. If any of the mounting bolts can be turned by hand, then check a nd  verify the entire installation before continuing.  Shims — Shims, another fairly basic item that often result in a number of problems, are intended for the correction of soft foot (see discussion below) as well as for adjusting the alignment of the machine. Shims should cover as much of the foot surface as possible (Photo 3) and be as thick as practical for the requirement, ensuring the smallest quantity of shims is used. Choosing shims that are too small for the motor foot area will result in a motor that is poorly supported (Photo 4). Using too many shims can result in a vibration issue similar to soft foot known as “sponge foot” — where the foot becomes springy  due to lack of rigidity in the support (similar to a leaf spring in a vehicle). Excessive movement of the affected foot will result.  Soft foot  — Soft foot can play a major influence in the vibration of an induction motor. Although any 

Basic Motor Vibration Troubleshooting Tips

http://ecmweb.com/print/motors/basic-motor-vibration-troubleshooting-tips

motor can be adversely affected, 2-pole machines are especially vulnerable to soft foot problems due to the eccentric electromagnetic forces within the air gap of their design. Perform a check for static soft foot as part of the installation and alignment of the machine.

Check static soft foot by first tightening all of the foot mounting bolts to the required torque level specified by the manufacturer. Then, starting with any foot, place a thousandths (0.001 in.) dial indicator vertically on the foot surface near the bolt location, leaving adequate space to loosen the bolt with a properly sized wrench (Fig. 1). Zero the indicator and begin to loosen the bolt. If the value on the dial indicator increases from zero, make note of the amount of the change — this is the amount of soft foot present. Each manufacturer may have its own criteria for soft foot, so follow those specific values. If practical, keep all levels of soft foot at less than one thousandth (0.001 in.). If soft foot is present, correct it by appropriate shimming. While the bolt is loose (and prior to shimming), it is recommended that you take a f eeler gauge and check the full perimeter of the foot to whatever extent practical. This helps you verify the foot is flat and not angled or distorted. If the foot is not flat, then complicated shim a rrangements may be required. Once the foot is properly shimmed, repeat the dial indicator check to verify the am ount of soft foot present after correction. If  the correction was successful, torque the foot mounting bolt appropriately. Check the next foot, repeating the process until you’ve checked and adjusted all of the mounting feet, as necessary. Determine Rotor Critical Speeds and System Natural Frequencies

Testing for rotor critical speeds and system natural frequencies can be complicated. Once you verify they exist, the following issues are some of the most difficult to c orrect.  Rotor critical speed  — You can use coast down testing to determine system natural frequencies, but this approach is most commonly used for determining rotor critical speeds. With very few exceptions, rotor critical speeds are only an issue when dealing with some 2-pole (and occasionally 4-pole) rotors. Suspect rotor critical speed problems when high levels of “one times shaft speed” (1×RPM) vibration amplitudes

Basic Motor Vibration Troubleshooting Tips

http://ecmweb.com/print/motors/basic-motor-vibration-troubleshooting-tips

are present, and balancing has had limited or no success. Although you can use bearing housing vibration data for this test, non-contact shaft probe data makes for better accura cy. Record 1×RPM vibration amplitude and phase angle data from the time the machine is at no-load speed until the shaft has stopped rotating (with data recorded in 10 RPM increments), and plot this data in a Bode or polar plot. It is recommended that no rotor critical speed be within 15% of operating speed for single speed machines. Users with machines operating on adjustable-speed drives having a critical speed within their operating range should consult with the manufacturer for possible recommendations. Note that you may also use coast down testing to aid in determining if an induction motor vibration problem is electrical or mechanical in nature. Monitor the vibration levels prior, during, and immediately after the power has been removed from the motor. If the vibration ceases or sharply declines almost immediately, then the problem typically stems from an electrical issue.  Natural frequencies/bump test  — System natural frequencies can also be quite problematic if they  coincide with system forcing frequencies. Suspect this type of problem when vibration is much higher in one axis than another — or when the vibration does not seem to be affected, regardless of the corrections performed. The best data for determination of a system natural frequency is provided via dual-channel impact testing using an instrumented modal hammer and a vibration transducer. Testing in this manner allows you to produce a frequency response function with phase data. Adding the phase data is beneficial,  because it allows you to better determine if a natural frequency is present in the system by comparison of  not only amplitude, but also phase shift.

 You can test horizontal machines in a number of locations (click here to see Fig. 2). These locations may be modified, depending upon need by focusing upon locations where a problem is known to exist or by increasing locations to include other measurements, such as frame skin, bearing brackets, equipment supports, or installation skids. Horizontal motors equipped with sleeve bearings must have any bearing housing or bracket testing performed while in a slow roll condition (200 to 300 RPM) so that the two brackets are not coupled by  the shaft. If left stationary, the resultant artificial stiffening will result in erroneous results. Horizontal motors equipped with anti-friction bearings are not affected by this and m ay have their bearing housings or brac kets impact tested while at rest.  Vertical machines have two principal locations you should target with impact testing, which correspond to the reed or natural rocking frequencies. These locations are both at the uppermost bracket, flange, or frame member of the machine with the two measurements being orthogonal (90°) to one another. For ease, this may   be with the main lead box and 90° from the main lead box or with the discharge piping and 90° to the discharge piping (click here to see Fig. 3). The 90° separation is important for this test, because external equipment,  boxes, piping, etc., can have a large effect on the natural frequency. The rotor does not need to be rotating for reed frequency testing.

Basic Motor Vibration Troubleshooting Tips

http://ecmweb.com/print/motors/basic-motor-vibration-troubleshooting-tips

 As a general rule of thumb, there should be no natural frequencies within ±15% of half times operating speed, one times operating speed, two times operating speed, one times line frequency, and two times line frequency — although some users may have different requirements. Adjustable-speed drive operation of machines may make avoidance of natural frequencies impractical. Natural frequency problems are typically difficult to correct, if  even practical, because changing the reed frequency of the system could require rework of the foundation. Coupling half and motor shaft keyway checks

 A frequent source of mechanical unbalance with motor startups stems from improper key trimming in coupling hubs. The ideal key installation uses a full key for the part of the shaft where the coupling hub is located and then steps down to a half key (Photo 5). Using a full key that does not step down to a half key will create a large mechanical unbalance (Photo 6). Always follow the manufacturer’s recommendations for best results. Even though the causes of m otor vibration seem almost endless, with a few straightforward checks and a n inquisitive attitude, you can minimize risk during motor and train startup and ma ximize overall reliability of the equipment.  Hamm is a service engineer and Evans is a senior test engineer with TECO Westinghouse, Round Rock, Texas. They can be reached at (512) 255-4141.

Source URL: http://ecmweb.com/motors/basic-motor-vibration-troubleshooting-tips