NATIONAL IRANIAN OIL COMPANY SOUTH PARS GAS FIELD DEVELOPMENT PHASES 6, 7 & 8 ENGINEERING SERVICES N.I.O.C.
DOCUMENT TITLE 56” ONSHORE PIPELINE
PHASE
AREA
SPY
3
BARRED TEE DATA SHEET
DOCUMENT No TRAIN/ DIS DOC UNIT 0000
PN
DT
SEQ
REV
005
B1
Page 3 of 3
Sketch for Guide Bar Design
B
B
Notes 1. All branch diameter wall thickness changes shall be made with tapered transition pieces of 1:5 minimum slope. 2. Barred Tees required at greater than 50% of pigged line size. 3. Weld procedure required for bars and tee. 4. Bar dimensions 50mmx9mm bars ≤ 36” ≥100mmx12mm. 5. Fabrication and Inspection requirements included in SPY-Y-0000-TY-SP-008 6. Manufacturer to transport free issue “pup pieces” from pipeline supplier.