AVEVA Integration Service Installation
Short Description
service...
Description
AVEVA Integration Service 1.2 Installation Guide
AVEVA Integration Service Installation Guide
Disclaimer Information of a technical nature, and particulars of the product and its use, is given by AVEVA Solutions Ltd and its subsidiaries without warranty. AVEVA Solutions Ltd and its subsidiaries disclaim any and all warranties and conditions, expressed or implied, to the fullest extent permitted by law. Neither the author nor AVEVA Solutions Ltd, or any of its subsidiaries, shall be liable to any person or entity for any actions, claims, loss or damage arising from the use or possession of any information, particulars, or errors in this publication, or any incorrect use of the product, whatsoever.
Copyright Copyright and all other intellectual property rights in this manual and the associated software, and every part of it (including source code, object code, any data contained in it, the manual and any other documentation supplied with it) belongs to AVEVA Solutions Ltd or its subsidiaries. All other rights are reserved to AVEVA Solutions Ltd and its subsidiaries. The information contained in this document is commercially sensitive, and shall not be copied, reproduced, stored in a retrieval system, or transmitted without the prior written permission of AVEVA Solutions Ltd Where such permission is granted, it expressly requires that this Disclaimer and Copyright notice is prominently displayed at the beginning of every copy that is made. The manual and associated documentation may not be adapted, reproduced, or copied, in any material or electronic form, without the prior written permission of AVEVA Solutions Ltd. The User may also not reverse engineer, decompile, copy, or adapt the associated software. Neither the whole, nor part of the product described in this publication may be incorporated into any third-party software, product, machine, or system without the prior written permission of AVEVA Solutions Ltd, save as permitted by law. Any such unauthorised action is strictly prohibited, and may give rise to civil liabilities and criminal prosecution. The AVEVA products described in this guide are to be installed and operated strictly in accordance with the terms and conditions of the respective licence agreements, and in accordance with the relevant User Documentation. Unauthorised or unlicensed use of the product is strictly prohibited. First published 2015. Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All rights reserved. AVEVA Solutions Ltd, High Cross, Madingley Road, Cambridge, CB3 0HB, United Kingdom.
Trademarks AVEVA is registered trademark of AVEVA Solutions Ltd or its subsidiaries. Unauthorised use of the AVEVA trademark is strictly forbidden. AVEVA product names are trademarks or registered trademarks of AVEVA Solutions Ltd or its subsidiaries, registered in the UK, Europe and other countries (worldwide). The copyright, trade mark rights, or other intellectual property rights in any other product, its name or logo
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
1
AVEVA Integration Service Installation Guide
ISSUE HISTORY Date
Issue No
Remarks
10/03/2015
1.0
Initial Version, Release Number 1.0
11/06/2015
1.1
Fix Version, Release Number 1.1
08/09/2018
1.2
Fix. Version, Release Number 1.2
SUMMARY OF CHANGES
Paragraph NA
Details NA
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
2
AVEVA Integration Service Installation Guide
Contents 1.
Introduction ........................................................................................................................................... 5
2.
License Activation ................................................................................................................................. 5
3.
Hardware and Software Requirements ................................................................................................... 5 3.1
Hardware Requirements ................................................................................................................. 5
3.2
Software Requirements................................................................................................................... 6
4.
Prerequisites for AVEVA Integration Service............................................................................................ 6
5.
Prerequisites to use different Data sources ........................................................................................... 15 5.1
Dabacon Based Products ............................................................................................................... 15
5.2
AVEVA P&ID .................................................................................................................................. 15
5.3
AVEVA Instrumentation/Electrical................................................................................................. 18
5.4
Excel ............................................................................................................................................. 20
6.
Procedure to retain Data Sources added in previous version. ................................................................ 21
7.
Installation Procedure:.......................................................................................................................... 23 7.1
Schematic Integration Components............................................................................................... 27
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
3
AVEVA Integration Service Installation Guide
This page has been deliberately left blank
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
4
AVEVA Integration Service Installation Guide
1. Introduction This guide is intended for IT Managers and support Users who are planning to implement AVEVA Integration Service 1.2. The Hardware & Software requirements sections present detailed requirements of the hardware, operating system, software packages and version numbers required for the installation of the product. Please follow all the instructions and read the information described at Sections 6 to install AVEVA Integration Service 1.2, they contain all the required information for new Users and existing Users.
2. License Activation The licensing of the AVEVA Integration Service product is managed by AVEVA’s ALS security system. To operate, AVEVA software must be able to access the correct ALS license file, which should be installed on either the Server, on the workstation, or on a networked workstation. ALS is a network license service which hands out floating licenses to clients, meaning that licenses are not tied to a certain workstation but can be used from any workstation where the software is installed, as long as the total number of licenses in use does not exceed the number of licenses purchased. The ALS guide is available on the AVEVA support site. Note: Although the disk contains several AVEVA products, the user will only be able to use the items that are licensed to them. The user will get an on-screen notification to warn them when the license is due for renewal. License Activation
3. Hardware and Software Requirements This section gives detailed requirements of the hardware, operating system, software packages and version numbers required to implement AVEVA Integration Service 1.2. Where the text identifies operating systems or 3rd party packages (e.g. Microsoft Excel), currently only English versions has been certified for use with AVEVA Integration Service 1.2.
3.1
Hardware Requirements
Intel(R) Core(TM) i5 2.8 GHz, RAM 4GB 15” to 17” monitor running in XVGA (1280 *1024) mode or greater.
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
5
AVEVA Integration Service Installation Guide
3.2
Software Requirements
Operating System as Microsoft Windows 7 SP1 Microsoft Data Access Components (MDAC) 2.6 or later Microsoft .NET Framework 4 Microsoft Message Queue (MSMQ) Server AVEVA Licensing System
Note: The user should have full Admin rights on the computer for accessing the Integration Service.
4. Prerequisites for AVEVA Integration Service Before installing AVEVA Integration Service 1.2 there are some steps to be done as prerequisites, they are: Turn on the MSMQ Server Core
Go to Control Panel > Programs and Features and select the Turn Windows features on or off option:
Check all the checkboxes under Microsoft Message Queue (MSMQ) Server and then click OK.
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
6
AVEVA Integration Service Installation Guide
The user must also verify that the ‘Message Queuing’ and ‘Message Queuing Triggers’ services are running (by running the command “services.msc” in 'Run' command window). If not, they must be started.
Do the Computer Management Setting as follows:-
Run the command ‘compmgmt.msc’ in the MS command window. Expand the node ‘Services and Applications’ in the left pane of Computer Management window. Open Message Queuing Open Private Queues © Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
7
AVEVA Integration Service Installation Guide Right-click the on ‘integration_tasks’ message queue and select Properties
Select the ‘Security’ tab of integration_tasks Properties window and click on ‘Advanced’ button.
Select the ‘Owner’ tab Advanced Security Settings
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
8
AVEVA Integration Service Installation Guide
Change the current owner to ‘Administrators’ by selecting ‘Administrators’ group in the section ‘Change owner to’ and click ‘Apply’ button.
Click the ‘Permissions’ tab © Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
9
AVEVA Integration Service Installation Guide
Click on ‘Add’ and add the name of the user who is going to configure the service, giving the full control.
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
10
AVEVA Integration Service Installation Guide
Click OK to close all the windows.
Existing P&ID Users For P&ID users the Middle tier service will be running already as below.
The user needs to uninstall the middle tier integration service by following steps: 1. Go to Control Panel. In Programs click on “Uninstall a Program”
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
11
AVEVA Integration Service Installation Guide 2. The lists of installed programs appear as below.
3. Right click on Aveva Schematic Middle Tier 1.0 and click on Change
4. The following window appears, click on Next.
5. Click on Change in the following window.
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
12
AVEVA Integration Service Installation Guide 6. In the following window click Schematic Integration and select Entire feature will be unavailable. And click on next.
7. Click on Change.
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
13
AVEVA Integration Service Installation Guide 8. The following screen will appear which shows the progress of re-installation.
9. Click on Finish.
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
14
AVEVA Integration Service Installation Guide
5. Prerequisites to use different Data sources There are some prerequisites to be set for using AVEVA Integration Service with different data source types.
5.1
Dabacon Based Products
AVEVA Products listed below should be installed on the same machine where the Integration Service is installed, so that they can be supported as data source by the service:
AVEVA Engineering AVEVA PDMS or E3D AVEVA OutFitting
5.2
AVEVA P&ID
To use AVEVA P&ID as Data Source Type, the user first needs to add those P&ID projects to AVEVA P&ID Report Service. This can be done using following process:
Run the ServiceEditor.exe by selecting AVEVA > Engineer > Manage > P&ID Data Service Editor from the All Programs menu or from the installed location by double-clicking on it:
Add the ‘pid.prj’ file of required P&ID project by clicking the Add button and browsing for the file.
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
15
AVEVA Integration Service Installation Guide
Click on the Save All button.
Note: The user needs to click on the Stop Service button and then Start Service button for the selection to take effect.
Finally, click on Exit.
The data from the added project can be confirmed by running ClientApplication.exe from the location below:
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
16
AVEVA Integration Service Installation Guide Set the Service Location by giving the correct machine name and port as shown below.
Test the service using the Test Service button to make sure it is OK.
Click on get 'Get Projects' and select the Project from the dropdown list.
Select table from the list of ‘ALL TABLES’ and click on ‘Retrieve Data’ to check that data is available.
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
17
AVEVA Integration Service Installation Guide
5.3
AVEVA Instrumentation/Electrical
To use AVEVA Instrumentation/Electrical as Data Source Type, the user first needs to add those Instrumentation/Electrical projects to AVEVA Instrumentation Integration Service. This can be done using following process: Run the Instrumentation Integration Service by selecting AVEVA Plant > Engineer > Instrumentation>Instrumentation Integration Service from the All Programs menu or from the installed location by double-clicking on it:
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
18
AVEVA Integration Service Installation Guide
2. Add ‘AvevaInstProjects.mdb’ file by clicking the Add Project button and browsing for the mdb file.
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
19
AVEVA Integration Service Installation Guide
Click on the Save button.
Note: The user needs to click on the Stop Service button and then Start Service button for the selection to take effect.
Finally, click on Close.
5.4
Excel
For using MS Excel as data source type, MS Office 2007 or later versions must be installed.
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
20
AVEVA Integration Service Installation Guide
6. Procedure to retain Data Sources added in previous version. User need to follow below procedure to retain the old data source details configured in the AVEVA Integration Settings Editor before installing latest version of AVEVA Integration Service. Steps to follow, 1. Cut/Copy the ‘DataSources.dat’ file from AVEVA Integration Service installed location. For example the AIS installed in below path, “D:\Program Files\AVEVA\Shared\AIS1.1 Components\AVEVA Integration Service”
2. Paste this file in a folder where normal user has access to that folder. For example the file is copied to below location, “C:\Users\Public\Documents\AVEVA\Aveva Integration Service”
3. Copy the folder path where the ‘DataSources.dat’ file is copied and open the
‘InterOpIntegrationWinService.config’ file in notepad from the AVEVA Integration Service installed location.
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
21
AVEVA Integration Service Installation Guide
4. Provide the folder location where ‘DataSources.dat’ file is copied to in the XML file.
5. Save the Configuration file and install the new version of AVEVA Integration Service. 6. After installation of new version of AVEVA Integration Service repeat the steps 3 & 4.
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
22
AVEVA Integration Service Installation Guide
7. Installation Procedure: Please run the ‘AVEVA_Integration_Service 1.2.msi’ from set up folder location and the Welcome Screen
would appear as shown below. Click ‘Next’ to go to the next page.
Figure1. Welcome Screen
Figure2. End User License Agreement Screen © Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
23
AVEVA Integration Service Installation Guide
Figure3. Custom Screen This is the Custom Setup screen. User can set the installation folder by clicking ‘Browse’ button if required. Click ‘Next’ to go to the next page.
Figure4. Custom Setup screen © Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
24
AVEVA Integration Service Installation Guide
Note: If Aveva Integration Service is running the following pop-up appears, the client needs to stop the service in order to avoid the pop-up.
Figure5: Service already running, need to stop before installation screen.
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
25
AVEVA Integration Service Installation Guide This is the Ready to Install AVEVA Integration Service screen. Click Install to start installing.
Figure6. Ready to Install AVEVA Integration Service screen This is the Progress Installation screen. This shows that installation is taking place.
Figure7. Progress Installation screen © Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.
26
AVEVA Integration Service Installation Guide This is the Installation completed screen.
Figure8. Installation completed screen Click Finish to complete installation and exit. Please refer to the AVEVA Integration Service User Guide for details about how to configure and use the Integration Service. Notes:
AIS 1.2 doesn’t require AIS 1.0 or AIS 1.1 to be installed in the machine. If AIS 1.2 is installed on top of AIS 1.0 or AIS 1.1 then it automatically upgrades to AIS 1.2 version. When AIS 1.2 is uninstalled then all AIS components are completely uninstalled from the machine.
7.1
Schematic Integration Components
Data Integration Integration Service: It is required for importing the data into AVEVA P&ID. Currently this service can import data from sources like AVEVA P&ID, Excel & SQL Server. Integration Client: This sample application can be used for verifying that the data source is properly setup on the Integration Service and able to fetch data from the source product. Notification Notification Service: It is required for importing the notification into AVEVA Integration service. Notification Client: This sample application can be used for verifying that the notification is properly setup on the Integration Service and able to see notification from the AVEVA integration service.
© Copyright 2015 to current year. AVEVA Solutions Limited and its subsidiaries. All Rights Reserved.