NOTES: 1. CONTRACTOR IS RESPONSIBLE TO REPLACE ITEM * TO A 32A RATING AND PROVIDE THE LINKWAY VICINITY AS SHOWN IN SLD (B)
Qualified Person Endorsement :
T
LTA Endorsement :
Project Title :
STANDARD INSTALLATION DETAILS
Drawing Title :
TYPICAL SINGLE LINE DIAGRAM FOR EXISTING OG-BOX (POB/LINKWAY/TAXI STAND/BUS SHELTER)
Designed
TYPICAL SINGLE LINE DIAGRAM FOR EXISTING OG-BOX (POB / LINKWAY / TAXI STAND / BUS SHELTER)
NURLY Scale
SCALE: NTS
N.T.S.
Checked MALVIN HO Drawn JULI
Approved MELVYN THONG Date JULY 2007
Drawing No. :
Rev.
-
L/ROAD/MES/SD/1001 Rev. $DATE$
$TIME$
$FILE$
Date
By
Description
Chk’d
App’d
CAD File Name : LROADMES-SD1001-.dgn
Sheet
1 of
1
A4
NOTES: 1. CONTRACTOR IS RESPONSIBLE TO REPLACE ITEM * TO A 32A RATING AND PROVIDE THE LINKWAY VICINITY AS SHOWN IN SLD(B)
Qualified Person Endorsement :
LTA Endorsement :
Project Title :
STANDARD INSTALLATION DETAILS
Drawing Title :
TYPICAL SINGLE LINE DIAGRAM FOR NEW OG-BOX (BUS SHELTER/LINKWAY)
Designed
TYPICAL SINGLE LINE DIAGRAM FOR NEW OG-BOX (BUS SHELTER / LINKWAY)
NURLY
SCALE: NTS
Scale N.T.S.
Checked MALVIN HO Drawn JULI
Approved MELVYN THONG Date JULY 2007
Drawing No. :
Rev.
-
L/ROAD/MES/SD/1002 Rev. $DATE$
$TIME$
$FILE$
Date
By
Description
Chk’d
App’d
CAD File Name : LROADMES-SD1002-.dgn
Sheet
1 of
1
A4
NOTES: 1. CONTRACTOR IS RESPONSIBLE TO REPLACE ITEM * TO A 32A RATING AND PROVIDE THE LINKWAY VICINITY AS SHOWN IN SLD(B).
Qualified Person Endorsement :
LTA Endorsement :
Project Title :
STANDARD INSTALLATION DETAILS
Drawing Title :
TYPICAL SINGLE LINE DIAGRAM FOR NEW OG-BOX (BUS SHELTER)
Designed
TYPICAL SINGLE LINE DIAGRAM FOR NEW OG-BOX (BUS SHELTER)
NURLY
SCALE: NTS
Scale N.T.S.
Checked MALVIN HO Drawn JULI
Approved MELVYN THONG Date JULY 2007
Drawing No. :
Rev.
-
L/ROAD/MES/SD/1003 Rev. $DATE$
$TIME$
$FILE$
Date
By
Description
Chk’d
App’d
CAD File Name : LROADMES-SD1003-.dgn
Sheet
1 of
1
A4
NOTES: 1. CONTRACTOR IS RESPONSIBLE TO REPLACE ITEM * TO A 32A RATING AND PROVIDE THE LINKWAY VICINITY AS SHOWN IN SLD(B).
Qualified Person Endorsement :
T
LTA Endorsement :
Project Title :
STANDARD INSTALLATION DETAILS
Drawing Title :
TYPICAL SINGLE LINE DIAGRAM FOR EXISTING OG-BOX (DBO BUS SHELTER/POB/LINKWAY/TAXI STAND)
Designed NURLY
TYPICAL SINGLE LINE DIAGRAM FOR EXISTING OG-BOX (DBO BUS SHELTER / POB / LINKWAY / TAXI STAND)
Scale
Checked MALVIN HO Drawn
Approved MELVYN THONG Date
SCALE: NTS N.T.S.
JULI
JULY 2007
Drawing No. :
Rev.
-
L/ROAD/MES/SD/1004 Rev. $DATE$
$TIME$
$FILE$
Date
By
Description
Chk’d
App’d
CAD File Name : LROADMES-SD1004-.dgn
Sheet
1 of
1
A4
LAND TRANSPORT AUTHORITY LOGO UV RESISTANT WINDOW C/W NEOPRENE SEAL
NAME PLATE
LAND TRANSPORT AUTHORITY LOGO
CONTRRACT NO: SERIAL NO: YEAR MANUFACTURE:
SPANNERS INTERNATIONAL PTE LTD 6 CHANGI NORTH STREET 1 SPANNERS BUILDING SINGAPORE 498825
ISO
Certified 9002Company
WEATHERPROOF TO IP 54 ABLOY MASTER KEY FOR POWERGRID
300
2 NOS. POWER GRID KWH METER
ABLOY MASTER KEY AS PER LTA’s REQUIREMENTS REMOVEABLE PLATE Qualified Person Endorsement :
PLINTH C/W OPENING FOR CABLE ENTRY 2 NOS 50mm HEAVY DUTY UPVC PIPE FOR POB ELECTRICAL DISTRIBUTION
LTA Endorsement :
2 NOS 100mm HEAVY DUTY uPVC LEAD IN C/W 90^ LONG BEND PIPES FOR POWER GRID INCOMING CABLING
SIDE VIEW
FRONT INTERNAL VIEW EXTERNAL VIEW
2 NOS 50mm HEAVY DUTY uPVC PIPE FOR FUTURE BUS SHELTER ELECTRICAL DISTRIBUTION
Project Title :
STANDARD INSTALLATION DETAILS
TYPICAL DETAIL OF OG-BOX SCALE: NTS Drawing Title :
TYPICAL DETAIL OF POB OG-BOX
Designed NURLY Scale N.T.S.
Checked MALVIN HO Drawn JULI
Approved MELVYN THONG Date JULY 2007
Drawing No. :
Rev.
-
L/ROAD/MES/SD/1005 Rev. $DATE$
$TIME$
$FILE$
Date
By
Description
Chk’d
App’d
CAD File Name : LROADMES-SD1005-.dgn
Sheet
1 of
1
A4
Back EXTERNAL BACK DOOR
FIX PLATE
100mm HEAVY DUTY UPVC PIPE FOR POB/LINKWAY ELECTRICAL DISTRIBUTION
2 NOS 100mm HEAVY DUTY UPVC LEAD IN C/W 90^ LONG BEND PIPES FOR POWER GRID INCOMING CABLING PARTITION
100mm HEAVY DUTY UPVC PIPE FOR BUS SHELTER ELECTRICAL DISTRIBUTION SUPPORT FOR BREAKER GLASS PARTITION 50mm HEAVY DUTY UPVC PIPE FOR BUS SHELTER ADVERTISING PANEL
EXTERNAL FRONT DOOR
EXTERNAL FRONT DOOR
Front
PLAN VIEW
Overall Length = min 1120mm
Depth = min 450mm
Depth = min 450mm
Overall Length = min 1120mm 420
POWER
POWER
GRID
GRID
1 KWH
1 KWH
METER
METER
Qualified Person Endorsement :
GLASS
GLASS
POB/LINKWAY SUPPORT FOR BREAKER
FIX PLATE
BUS SHELTER
LTA Endorsement :
BI Supply and Installed By PG
EXTERNAL FRONT DOOR PARTITION
REMOVABLE PLATE
REMOVABLE PLATE
REMOVABLE PLATE
Project Title :
Y
STANDARD INSTALLATION DETAILS 2 NOS 100mm HEAVY DUTY UPVC LEAD IN C/W 90^ LONG BEND PIPES FOR POWER GRID INCOMING CABLING
PLINTH C/W OPENING FOR CABLE ENTRY
50mm HEAVY DUTY UPVC PIPE FOR BUS SHELTER ADVERTISING PANEL 100mm HEAVY DUTY UPVC PIPE FOR BUS SHELTER ELECTRICAL DISTRIBUTION
100mm HEAVY DUTY UPVC PIPE FOR POB/LINKWAY ELECTRICAL DISTRIBUTION
EXTERNAL BACK VIEW
EXTERNAL VIEW
INTERNAL SIDE VIEW
INTERNAL FRONT VIEW
Drawing Title :
TYPICAL DETAIL OF POB OG-BOX
SIDE VIEW
Designed
A
NURLY Scale
TYPICAL DETAIL OF OG-BOX
N.T.S.
SCALE: NTS
Drawing No. :
Checked MALVIN HO Drawn JULI
Approved MELVYN THONG Date JULY 2007 Rev.
-
L/ROAD/MES/SD/1006 Rev. $DATE$
$TIME$
$FILE$
Date
By
Description
Chk’d
App’d
CAD File Name : LROADMES-SD1006-.dgn
Sheet
1 of
1
A4
1
2
3
7500 750
3000
3000
1500
1500
750
1500
1500
EARTH PIT (TOTAL RESISTANCE < 10ohm)
MS ANGLE ROOF FASCIA TO ENGR’S DTL
A
M.S. RHS POST UNDERNEATH TO ENGR’S DTL
ROOF CAPPING @ 1500mm C/C TO MFR’S DTL
PVC CABLE IN FLEXIBLE CONDUIT
MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1 mm THK TOP PANEL TO SO’S APPROVAL
3
PROPOSED 1 x 18W (IP 65) LIGHT FITTING 50 X 50 X 3 THK ALUM. ANGLE PLATE FOR BUS STOP ADDRESS & NUMBER SIGN PLATE
BUS STOP ADDRESS & NUMBER SIGN PLATE TO FACE ONCOMING TRAFFIC IN ACCORDANCE TO LTA STD DRAWING NO. LTA/ARCH/CF/97/8/13 LATEST REVISION
Qualified Person Endorsement :
TYPICAL LIGHTING LAYOUT PLAN SCALE: NTS
1
2
3
7500 750
3000
3000
750
EARTH PIT (TOTAL RESISTANCE < 10ohm)
ROOF EAVES ABOVE
LTA Endorsement :
2 NOS. 50mm HEAVY DUTY UPVC PIPE C/W PULL WIRE
NOTICE BOARD WITH ALUM. FRAME C/W 10mm THK. TEMPERED GLASS
600 REFUSE BIN
A
NEW OG BOX M.S. RHS POST @ 3000 mm C/C TO ENGR’S DTL
ALUM. SEAT TO DTL
2 NOS. 100mm HEAVY DUTY UPVC HEAD-IN 90^ LONG BEND PIPES FOR POWERGRID’S INCOMING CABLE
3 1400
100
1 NO. 50mm HEAVY DUTY UPVC PIPE C/W PULL WIRES FROM 0G-BOX TO ADVERTISING PANEL
1400 1 NO. ELECT. PIPE FOR ADVERTISEMENT PANEL (AP) TO BE LOCATED AT THE DOWNSTREAM EDGE OF BUS SHELTER
Project Title :
STANDARD INSTALLATION DETAILS CONC. SLAB TO ENGR’S DTLS COMPLETE WITH 20mm THK GRANOLITHIC FINISHES TO SO’S APPROVAL
200 WIDE YELLOW LINE IN HOT APPLIED THERMOPLASTIC ROAD MARKING MATERIALS
LINE OF ROAD KERB OR ROAD RESERVE LINE
Drawing Title :
TYPICAL LIGHTING LAYOUT PLAN AND LIGHTNING PROTECTION SYSTEM FOR BUS SHELTER (WITH OR WITHOUT RAILING) Designed NURLY
ROAD
Scale N.T.S.
TYPICAL LIGHTNING PROTECTION SYSTEM LAYOUT PLAN
$FILE$
Drawn JULI
Approved MELVYN THONG Date JULY 2007 Rev.
-
L/ROAD/MES/SD/1007 Rev.
$TIME$
MALVIN HO
Drawing No. :
SCALE: NTS
$DATE$
Checked
Date
By
Description
Chk’d
App’d
CAD File Name : LROADMES-SD1007-.dgn
Sheet
1 of
1
A4
A
1
2
3000
3
MIN. 600
300
2700
7500 750
3000 1500
3000 1500
750
1500
1500
MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1 mm THK TOP PANEL TO SO’S APPROVAL
BUS STOP ADDRESS & NUMBER SIGN PLATE TO FACE ONCOMING TRAFFIC IN ACCORDANCE TO LTA STD DRAWING NO. LTA/ARCH/CF/97/8/13 LATEST REVISION (TO BE BOLTED TO ALUM. ANGLE PLATE)
MS ANGLE ROOF FASCIA TO ENGR’S DTL PROPOSED 1 x 18W (IP65) LIGHT FITTING
3^ FALL
LIGHT FITTING TO M&E SPECS & SHALL NOT PROTRUDE FROM M.S. RAFTER / CONTRACTOR TO PROPOSE FIXING BRACKET FOR LIGHT FITTING
M.S. RHS TO ENGR’S DETAIL
1000
PVC CABLE IN PVC FLEXIBLE CONDUIT
M.S. ’C’ CHANNEL RAFTER @ 3000 mm C/C
1000
TO ENGR’S DETAIL G.I. PIPE ALONG BACK OF M.S. FASCIA FOR ELECT. CABLES TO M&E DWG. & SPEC.
LIGHT FITTING TO M&E SPECS
M.S. ’C’ CHANNEL RAFTER @ 3000 mm C/C TO ENGR’S DETAIL M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL M.S. ANGLE ROOF FASCIA TO ENGR’S DETAIL
NEW OG BOX (IP55) LOCATION SHALL BE SUBJECTED TO SITE CONDITIONS AND POWERGRID’S APPROVAL
M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL
ELECTRICAL CABLE IN PVC FLEXIBLE PIPE IN SUPPORT POST
CONC. SLAB TO ENGR’S DTL COMPLETE WITH 20mm THK GRANOLITHIC FINISHES TO SO’S APPROVAL NOTICE BOARD WITH ALUM. FRAME
REFUSE BIN TO BE FIXED IN POSITION
ALUM SEAT TO DETAIL
C/W 10mm THK. TEMPERED GLASS ALUM. SEAT TO DTL
300 CONC. SLAB TO ENGR’S DTLS COMPLETE WITH 20mm THK GRANOLITHIC FINISHES TO SO’S APPROVAL CONDUIT ENCASED IN CONCRETE
CABLE ENTRY ACCESS PANEL (REFER TO TYPICAL SUPPORT POST DETAIL)
FFL
FFL
ROAD FOOTING TO ENGR’ S DETAIL 6m PVC EARTH BONDING CABLE IN 25mm HEAVY DUTY UPVC PIPE
2 NOS 50mm HEAVY DUTY UPVC PIPES
ELEVATION 1
2 NOS 100mm HEAVY DUTY UPVC PIPES LEAD IN 90^ LONG BEND PIPES FOR POWERGRID INCOMING CABLING
SECTION A-A CATCH BASIN AND UPVC PIPE IN
(REFUSE BIN NOT SHOWN FOR CLARITY) Scale 1 :20
TYPICAL FRONT ELEVATION OF BUS SHELTER (WITHOUT RAILING)
TYPICAL SECTION OF BUS SHELTER (WITHOUT RAILING)
SCALE: NTS
SCALE: NTS
REF. DWG. NO. L/STLBS/AR/STD/0002
Qualified Person Endorsement :
ACCORDANCE WITH THE CURRENT LTA STANDARD DETAILS OF ROAD ELEMENTS
A
1
2
3000
3 300
MIN. 600 2700
7500 750
3000 1500
3000 1500
750
1500
1500
LTA Endorsement :
MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1 mm THK TOP PANEL TO SO’S APPROVAL
BUS STOP ADDRESS & NUMBER SIGN PLATE TO FACE ONCOMING TRAFFIC IN ACCORDANCE TO LTA STD DRAWING NO. LTA/ARCH/CF/97/8/13 LATEST REVISION (TO BE BOLTED TO ALUM. ANGLE PLATE)
PROPOSED 1 x 18W (IP65) LIGHT FITTING
MS ANGLE ROOF FASCIA TO ENGR’S DTL 3^ FALL
LIGHT FITTING TO M&E SPECS & SHALL
M.S. RHS TO ENGR’S DETAIL
1000
M.S. ’C’ CHANNEL RAFTER @ 3000 mm C/C
1000
NOT PROTRUDE FROM M.S. RAFTER / CONTRACTOR TO PROPOSE FIXING BRACKET FOR LIGHT FITTING
PVC CABLE IN PVC FLEXIBLE CONDUIT
TO ENGR’S DETAIL G.I. PIPE ALONG BACK OF M.S. FASCIA FOR ELECT. CABLES TO M&E DWG. & SPEC.
LIGHT FITTING TO M&E SPECS
M.S. ’C’ CHANNEL RAFTER @ 3000 mm C/C TO ENGR’S DETAIL M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL M.S. ANGLE ROOF FASCIA TO ENGR’S DETAIL
NEW OG BOX (IP55) LOCATION SHALL BE SUBJECTED TO SITE CONDITIONS AND POWERGRID’S APPROVAL
S/S RAILING TO BE PROVIDED WHERE THERE IS SUDDEN GREAT DIFFERENCE IN LEVEL
M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL
ELECTRICAL CABLE IN PVC REFUSE BIN TO BE FIXED IN POSITION
Project Title :
FLEXIBLE PIPE IN SUPPORT POST
CONC. SLAB TO ENGR’S DTL COMPLETE WITH 20mm THK GRANOLITHIC FINISHES TO SO’S APPROVAL NOTICE BOARD WITH ALUM. FRAME
ALUM SEAT TO DETAIL
C/W 10mm THK. TEMPERED GLASS
BONDING TO ALUMINIUM SEAT
ALUM. SEAT TO DTL
STANDARD INSTALLATION DETAILS
300
CONDUIT ENCASED IN CONCRETE FFL
FFL
ROAD CABLE ENTRY ACCESS PANEL (REFER TO TYPICAL SUPPORT POST DETAIL)
Drawing Title : FOOTING TO ENGR’ S DETAIL 6m PVC EARTH BONDING CABLE IN 25mm HEAVY DUTY UPVC PIPE
Thank you for interesting in our services. We are a non-profit group that run this website to share documents. We need your help to maintenance this website.