Atp-rtn600_v1 3 Huawei

July 19, 2018 | Author: ryl_fans_neh | Category: Antenna (Radio), Hertz, Microwave, Radio, Telecommunications Engineering
Share Embed Donate


Short Description

Description : ato rtn600 huawei...

Description

Optix RTN 600 Microwave Acceptance Test Test

ACCEPTANCE TEST DATA MICROWAVE RADIO SYSTEM OPTIX RTN 600

STATION A

:

______________________________  

STATION B

:

______________________________  

Prov Provid ided ed by: by: ____ ______ ____ ____ ____ ____ ____ ____ ___ _  Approved by:_______________ by:___________________ ____

Date Date:_ :___ ____ ____ ____ ____ ____ ____ ____ ___  _   _  Date:__________________  Date:__________________   _ 

Optix RTN 600 Microwave Acceptance Test

C ON TE NT :

1.

Visual Check

2.

Configuration Check

3.

Loop Back Test (Local and remote)

4.

Receive Power Level Result

5.

Protection Switching Test

6.

Interference Check

7.

Power Voltage Check

8.

Clock Setting Check

9.

Network Configuration

10.

Ethernet Service Connectivity

11.

Terminal Inventory Check

12.

Browse Alarm Check

13.

ATPC Test

14.

BER Test Measurement

15.

Attachment BER Test Result

Optix RTN 600 Microwave Acceptance Test

1)

Visual Check 1) Serial Number  Station: A _________________________________________  UNIT

Serial No

IDU ODU 1 ODU 2(*) Hybrid(*) Antenna (*) Fit only applicable Cell and if equipped Station: B _________________________________________  UNIT

Serial No

IDU ODU 1 ODU 2(*) Hybrid(*) Antenna (*) Fit only applicable Cell and if equipped

2) Antenna Antenna

Diameter (M)

Height (M)

Station:A ___________________ 

Polarization □Vertical □Horizontal

Station: B ___________________ 

□Vertical □Horizontal

Item Check

OK

NOK

3)

Check the physical Out-door installation.





4)

Check the Radio indoor equipment installation.





5)

Indoor Cable rack and structure installation.





6)

Labeling.





7)

Grounding cable installation





Optix RTN 600 Microwave Acceptance Test

2)

Configuration Check Station A Set-Up

Channel 1

Channel 2

Transmitted frequency

(MHz)

(MHz)

Received frequency

(MHz)

(MHz)

Frequency Plan (*)

(MHz)

(MHz)

dBm

dBm

Sub Band Transmitted power requested (*) Only in case of Frequency plan setting Station B Set-Up

Channel 1

Channel 2

Transmitted frequency

(MHz)

(MHz)

Received frequency

(MHz)

(MHz)

Frequency Plan (*)

(MHz)

(MHz)

dBm

dBm

Seb Band Transmitted power requested (*) Only in case of Frequency plan setting

3. Loop Back Test (Local and remote) Loop Back Test Station A

Local Tributary □ OK □ NOK

Station B

Local Tributary □ OK □ NOK

4. Receive Power Level Result Item

Station A ODU 1

Station B

ODU 2 (**)

ODU 1

ODU 2 (**)

Rx level in link budget

dBm

dBm

dBm

dBm

Rx Level

dBm

dBm

dBm

dBm

Tx Power

dBm

dBm

dBm

dBm

(**) if Applicable

5. Protection Switching Test System Type : □ 1+1HSB □ 1+1FD □ 1+1SD Site

Switching Result

Station A



OK □ NOK □NA(*)

Station B



OK □ NOK □NA(*)

Optix RTN 600 Microwave Acceptance Test

(*) if the configuration only 1+0 This test includes BER Test measurement to check the following: •

No errors on F/D and S/D Protection Switching Test



Errors on HSB Protection Switching Test.

6. Interference Check Item

Station A (Tx Off on B)

Station B (Tx Off on A)

ODU 1

ODU 1

ODU 2 (**)

ODU 2 (**)

Receive Level (*) (*) Receive power level