API 682 MECHANICAL SEAL DATA SHEET FOR CENTRIFUGAL AND ROTARY PUMPS
.
MANUFACTURER:
DETROIT HEAVY OIL UPGRADE PROJECT
MODEL NUMBER:
MICHIGAN REFINING DIVISION
SERIAL NUMBER:
A2IS 4P62
INQUIRY NUMBER:
A2IS-4-0601
P.O. NUMBER:
1
SHEET:
CLIENT:
2
PROJECT NAME:
3
PLANT:
4
SITE:
5
UNIT NUMBER:
4 - VACUUM UNIT
APPLICABLE TO:
6
SERVICE:
SLOP WAX PUMP
UNITS STANDARD FOR THIS DATA SHEET:
7
INFORMATION BELOW TO BE COMPLETED:
2HPX9A One (1) PROPOSAL
BY SEAL VENDOR
PURCHASE
AS BUILT
US CUSTOMARY UNITS
SEAL VENDOR OR PURCHASER
SEAL SPECIFICATION - (REFERENCE 4.1, FIGURES 1 TO 6)
8 9
CATEGORY
10
TYPE
11
(CODE - CW)
12
A'RNGMNT
13
1 (3.2)
SEAL CATEGORY 1 (4.1.1)
SEAL CATEGORY 2 (4.1.1)
SEAL CODE (ANNEX D)
TYPE A (3.72)
TYPE B (3.73)
ALTERNATIVE STATIONARY (TYPE A AND B)
TYPE C (3.74)
ALTERNATIVE ROTATING (TYPE C)
DEFAULT CONFIG 1 CW-FX
1 CW-FL
BUFFER
LIQUID
DIST. FLUSH
20
BARRIER
LIQUID
21
SLEEVE-SHAFT DRIVE
16
2 (3.3)
17 18 19
3 (3.4)
FX
2
SINGLE SPRING (TYPE A)
ALTERNATIVE BUSH
15
C2A2C325261
FLUSH PLANS (SEE ANNEX G)
ALTERNATIVE DESIGN
14
DIST. FLUSH
01
11
14
23
32
50
61
02
13
21
31
41
51
62
01
13
23
41
62
75
02
14
31
52
71
76
11
21
32
61
72
2 CW-CW
GAS
2 CW-CS
2 NC-CS
FX
3 CW-FB
3 CW-BB
FX
01
13
53A
54
3 CW-FF
TANGENTIAL LBO
02
14
53B
61
GAS
3 NC-BB
3 NC-FF
3 NC-FB
11
32
53C
62
TANGENTIAL LBO CONN'N DIST. FLUSH
SET-SCREW INTO SHAFT
2 74
ALTERNATIVE (6.1.3.13) - SPECIFY:
2
MATERIALS (REFERENCE 6.1.6 AND ANNEX B)
22 23
SECONDARY SEALS
24
FKM
25
SPIRAL WOUND GASKET
SIC VS SIC
26
NBR
SS - SIC
27
OTHER:
OTHER:
SEAL FACES
FFKM
CARBON VS SIC
METAL BELLOWS (Outboard)
SPRINGS
METAL PARTS
UNS N 10276 (TYPE B)
UNS N 10276
UNS S 31600 / S31635
(Inboard)
UNS N 07718 (TYPE C)
OR UNS N 06455
UNS N 10276
RB - SIC
UNS N 08020
UNS S 31600
UNS N 08020
OTHER:
OR S 31635
OTHER:
MECHANICAL SEAL DATA
28
FLOWSERVE
29
SEAL VENDOR:
30
DATA REQUIREMENTS FORM (ANNEX J)
31
SEAL / TYPE:
32
SEAL DRAWING NUMBER:
33
VENDOR'S SEAL CODE:
34
MODIFIED FACES FOR SEAL PERFORMANCE TEST
ALTERNATIVE SEAL FOR PUMP PERFORMANCE TEST DYNAMIC SEALING PRESSURE RATING (3.19):
300
PSIG
STATIC SEALING PRESSURE RATING (3.69):
300
PSIG
982935 (Rev. A)
MAXIMUM ALLOWABLE TEMPERATURE (3.40)
750
°F
HXCX / HPCX
MINIMUM DESIGN METAL TEMPERATURE (6.1.6.11.1)
BXHH / BXHH - 2375 / 2375
°F
36
ASME B 73.1 & 2
37
BOLT ON CHAMBER
SEAL CHAMBER FLUSH PORT REQUIRED
SEAL CHAMBER VENT REQUIRED
38
FLOATING THROAT BUSHING
FIXED THROAT BUSHING
CYLINDRICAL
TAPERED
ISO 13709
ISO 3069 - C
OTHER, SPECIFY:
SEAL CHAMBER HEATING REQUIRED
PUMP DATA
39
PUMP DESIGN
PUMP OPERATING PRESSURE
41
MANUFACTURER:
42
MODEL:
43
FRAME SIZE:
44
CASE MATERIAL:
FLOWSERVE
SUCTION PRESSURE RATED:
2HPX9A
-9
PSIG
DISCHARGE PRESSURE:
A8(Mod-316L SS)
61.1
PSIG
SEAL CHAMBER
SHAFT 12.85 PSIG
NORMAL PRESSURE:
HORIZONTAL
MSDP (3.42) MIN.:
PSIG
DIAMETER:
MSDP (3.42) MAX.:
PSIG
SHAFT SPEED:
MSSP (3.44)
PSIG
ROTATION
VERTICAL
1.95
IN
3,550 CW
RPM CCW
FLUID DATA (QUENCH, BUFFER, AND BARRIER FLUID DATA)
45 46
PUMPED STREAM:
47
TYPE OR NAME:
48
DISSOLVED CONTAMINANT: CL2 :
49
ATMOSPHERIC BOILING PT (LIQUID):
VACUUM SLOP WAX
CONCENTRATION:
H2S:
PPMW
PPMW
51
OTHER CORROSIVE/ERROSIVE:
52
PUMPING TEMPERATURE:
53
MIN.:
54
SPECIFIC GRAVITY AT TEMPERATURE INDICATED (LIQUID)
55
AT NORMAL TEMP:
56
VAPOR PRESSURE AT TEMPERATURE INDICATED (LIQUID) AT NORMAL TEMP:
58
FLUSH FLUID (PLAN 32)
4.9 wt% Sulfur
OTHER:
FLUID SOLID AT AMBIENT °F
POUR POINT:
0.87
663
°F
MAX.:
700
°F
PSIA
REGULATION LEVEL:
PSIA
CON'N:
60
FLUID TEMPERATURE:
61
MIN.:
62
SPECIFIC GRAVITY AT TEMPERATURE INDICATED (LIQUID)
63
AT NORMAL TEMP:
64
VISCOCITY AT NORMAL TEMPERATURE (LIQUID):
PPMV
SPECIAL PUMP CLEANING PROCEDURES:
AT MAXIMUM TEMP.:
HVGO
ALTERNATIVE PROCESS FLUIDS AND CONCENTRATIONS: VAPOR PRESSURE AT TEMPERATURE INDICATED (LIQUID)
%
0.85
AT NORMAL TEMP:
PSIA
NORMAL:
0.84
494
°F
MAX.:
ISSUE STATUS
°F
820
2.1
200
888
°F
PSIG
0.81
FLOW RATE REQUIRED:
MAX.:
GPM
MIN.:
GPM
cP
SUPPLY PRESSURE:
MAX.:
PSIG
MIN.:
PSIG
REVISION LOG DATE
PSIA
°F
BOILING POINT AT SEAL CHAMBER PRESSURE: AVAILABLE SUPPLY PRESSURE:
AT MAXIMUM TEMP:
65
579
0.9
AT MAXIMUM TEMP.:
ATMOSPHERIC BOILING POINT (LIQUID):
°F
°F
STREAM IS REGULATED FOR FUGITIVE OR OTHER EMITIONS
SEAL VENDOR REVIEW REQUIRED
TYPE OR NAME:
AT:
STREAM CAN PLATE OUT OR DECOMPOSE UNDER:
AT MAXIMUM TEMP.:
1
°F
PUMPED STREAM SOLIDIFIES UNDER SHEAR AGENTS THAT POLYMERIZE:
NORMAL:
cP
4 (185 at 85 F during startup)
FLAMMABLE
SOLIDIFIES AT:
°F
57
PPMW
°F
VISCOCITY AT NORMAL TEMP. (LIQUID): HAZARDOUS
AT
SOLID CONTAMINANT:
85
%
WET
OTHER:
50
59
2
SEAL CHAMBER DATA
35
40
REV
No. Stages: 1
NUMBER REQUIRED:
BY PURCHASER
2
OF
FLOWSERVE
1
DETROIT, MICHIGAN
A2IS-4-0601
RFQ NUMBER:
Note: This data sheet has been modified from that in the annex of API Standard 682, 3th Edition, September 2004.
MARATHON OIL COMPANY
CONTRACT: TAG ITEM NUMBER:
66
REV.
BY
CHECKED
APPROVED
67
0
Issued for Supplier Input
2/8/08
ON
TKS
BE
68
1
Issued for Purchase
2/22/08
ON
TKS
BE
69
2
Supplier comment for AS-BUILT
7/1/09
PK
JS
70
File Name:'file:///var/www/apps/conversion/tmp/scratch_1/257795735.xls'#$Sheet 1
API 682 MECHANICAL SEAL DATA SHEET FOR CENTRIFUGAL AND ROTARY PUMPS
.
MANUFACTURER:
DETROIT HEAVY OIL UPGRADE PROJECT
MODEL NUMBER:
MICHIGAN REFINING DIVISION
SERIAL NUMBER:
A2IS 4P62
2
SHEET:
PROJECT NAME:
3
PLANT:
4
SITE:
5
UNIT NUMBER:
4 - VACUUM UNIT
APPLICABLE TO:
6
SERVICE:
SLOP WAX PUMP
UNITS STANDARD FOR THIS DATA SHEET:
7
INFORMATION BELOW TO BE COMPLETED:
No. Stages: 1 0 One (1)
PROPOSAL
BY SEAL VENDOR
PURCHASE
SEAL VENDOR OR PURCHASER
QUENCH MEDIUM (PLAN 51, 62): TYPE OR NAME:
BUFFER / BARRIER MEDIUM
SUPPLY TEMPERATURE:
MAX.:
°F
MIN.:
°F
FLOW RATE REQUIRED:
MAX.:
GPM/SCFH
MIN.:
GPM/SCFH
SPECIFIC GRAVITY AT TEMPERATURE INDICATED (LIQUID)
TYPE OR NAME:
AT NORMAL TEMP:
13
PURCHASER SELECTION
VAPOR PRESSURE AT TEMPERATURE INDICATED (LIQUID)
14
SEAL VENDOR REVIEW
15
FLOW RATE REQUIRED:
MAX.:
GPM/SCFH
MIN.:
GPM/SCFH
ATMOSPHERIC BOILING POINT (LIQUID):
16
SUPPLY PRESSURE:
MAX.:
PSI
MIN.:
PSI
VISCOCITY AT NORMAL TEMPERATURE (LIQUID):
17
FLUID OPERATING TEMPERATURE:
18
MIN.:
AT MAXIMUM TEMP.:
AT NORMAL TEMP:
°F
PSIA
AT MAXIMUM TEMP.:
CONTROL VOLTAGE:
21
ELECTRICAL AREA:
22
DESIGN AMBIENT:
NORMAL:
°F
MAX.:
°F
MIN.:
-20
°F
105
MAX.:
COOLING H2O PRESSURE:
°F
PSIG
27
SPECIAL REQUIREMENTS FOR HAZARDOUS SERVICE
FLOWSERVE SEALS
EQUIPMENT SUPPORT SUPPLIER:
ISO 7
ASME B 1.20.1
FILLING SYSTEM SUPPLIER: ASME CODE STAMP REQUIRED
28
EN 13445 OR OTHER CODE APPLICABLE:
8 GALLONS
29
SPECIAL CLEANING AND DECONTAMINATION REQUIREMENTS
RESERVOIR CAPACITY (8.5.4.3):
30
UTILITY MANIFOLD CONNECTIONS REQUIRED (8.4.4)
NLL TO GLAND PLATE HEIGHT (8.5.4.2):
31
TYPE AND SPECIFICATION OF HEAT TRACING (8.6.5.8)
RESERVOIR MAWP (3.41):
32
SET PRESSURE RANGE: THERMAL RELIEF VALVES REQUIRED (9.8.3)
EQUIPMENT REFERENCE / CODE:
38
COOLING WATER LINES SUPPLIER: TUBING
ISO 15549
BY BUYER
COOLING WATER FLOW RATE:
GPM
41
SIGHT FLOW INDICATORS (8.4.3)
OPEN
42
200
°F
2
0
MIN:
PSIG
DAYS
REQUIRED COOLING WATER RATES & EQUIP. PRESSURE DROP:
RISING PRESSURE (ARR 2) SET AT:
PSIG
FALLING PRESSURE (ARR 3) SET AT:
PISG
TEST BASE H / Q CURVE FOR INTERNAL CIRCULATION DEVICE EXTERNAL CIRCULATION PUMP (8.6.3.1)
PLAN 62, 65 SYSTEMS
CLOSED
CONNECTING LINE SUPPLIER:
43
PRIMARY EQUIPMENT
GPM
PRESS. DROP
PSI
44
SECONDARY EQUIP.
GPM
PRESS. DROP
PSI
TUBING
(PRESS. DROP SHALL BE SYSTEM NET WHEN PIPING FURN. BY PUMP VENDOR)
PLAN 72 AND 74 SYSTEMS EQUIPMENT SUPPORT SUPPLIER:
BY BUYER
CONNECTING LINE SUPPLIER:
PIPING (8.5.2.2)
EQUIPMENT SUPPLIER:
PLAN 11, 13, 14, 21, 23, 31, 32, AND 41 SYSTEMS TUBING
AT: PSIG
HIGH LEVEL ALARM REQUIRED (8.5.4.2.i)
GALVANIZED PIPING (8.4.2)
40
48
30
PRESSURE SWITCH (8.5.4.2.h) TO ACTIVE ON: AIR COOLED
37
39
PSIG
TEMPERATURE INDICATOR (PLANS 53B AND 53C)
HEAT EXCHANGER SUPPLIER: WATER COOLED
620 MAX.:
SYSTEM HOLD-UP PERIOD (PLANS 53B AND 53C):
COOLING SYSTEM (PLAN 21, 22, 23, 41, 53B, 53C)
36
HIGH FLOW ALARMSWITCH (8.6.6.5)
PLAN 75 AND 76 SYSTEMS
PIPING (8.5.2.2)
49
RESTRICTION ORIFICE NIPPLE IN FLUSH LINE (8.5.2.4)
EQUIPMENT SUPPORT SUPPLIER:
50
CYCLONE SEPARATOR SUPPLIER:
HIGH LEVEL ALARM SWITCH (8.6.6.5)
51
PLAN 32 EQUIPMENT SUPPLIER:
52
PLAN 32 FLOW INDICATOR
54
PSIG
PLAN 52 AND 53 SYSTEMS CONTINUED
PIPE TAPER THREADS (8.1.9)
53
DESIGN:
ACCESSORIES (CLAUSES 8 AND 9)
26
47
°F
NOR.:
ATEX (EC DIRECTIVE 94/9/EC)
GENERAL JOINT USER / VENDOR LAYOUT OF EQUIPMENT (8.14)
46
BTU / H
COOLING H2O SUPPLY TEMPERATURE:
25
45
BTU / H-FT-°F
COOLING HEATING REQUIRED (+ OR -):
CLASS 1, GROUPS C, D, DIVISION 2
23
35
cP
SITE AND UTILITIES
20
34
PSIA
°F
SPECIFIC HEAT AT NORMAL TEMPERATURE:
19
33
AS BUILT
US CUSTOMARY UNITS
12
24
BY BUYER
TEST CONNECTION (8.6.5.4)
PLAN 32 TEMPERATURE INDICATOR
INSTRUMENTATION
PLAN 52 AND 53 SYSTEMS
USER SPECIFICATION REFERENCE FOR INSTRUMENTATION / CONROLS:
STANDARD (FIG G-27)
A3R111016-01 with Parker fittings
ALTERNATIVE (FIGURE G-28)
2
55
DIMENSIONAL VARIATIONS TO STANDARD (FIGURE G-27):
PRESSURE GAUGES (9.4)
OIL FILLED PRESSURE GAUGES (9.4.3)
56
DIMENSIONAL VARIATIONS TO ALTERNATIVE (FIGURE G-28):
PRESSURE SWITCHES (9.5.2):
TRANSMITER (9.5.2.3)
57
ALTERNATIVE FABRICATION STANDARD:
LEVEL SWITCHES (9.5.3)
TRANSMITER (9.5.3.2)
58
FLOWSERVE SEALS
PRIMARY EQUIPMENT SUPPLIER:
59 60
SUPPLIER'S REFERENCE / CODE:
A3R111016-01
HYDROSTATIC
SUPPLIER'S REFERENCE / CODE:
62
TUBING
CAPACITANCE
ULTRASONIC
LEVEL INDICATORS (9.6)
BUYER
CONNECTING LINES SUPPLIER:
61
2
WELD PAD
EXTERNAL, REMOVABLE (9.6.2)
FLOW INSTRUMENTS (9.7)
TRANSMITER (9.7.3)
SCH 80 PIPING (8.5.44.9)
INSPECTION AND TESTING
63 64
PURCHASER PARTICIPATION IN INSPECTION AND TEST SPECIFY:
65
INSPECTOR'S CHECK LIST (10.1.17 AND ANNEX H)
66
PURCHASER APPROVAL REQUIRED FOR WELDED CONNECTION DESIGNS (6.1.6.10.5)
OPTIONAL QUALIFICATION TESTING REQUIRED (10.3.1.1.2)
67
HARNESS TEST (10.2.3.k) REQUIRED FOR:
MODIFIED FACES FOR PUMP TEST (10.3.5.1) SEE PAGE 1, LINE 34
68
100% INSPECTION OF ALL WELDS (6.1.6.10.5) USING: LIQUID PENETRANT
RADIOGRAPHIC
MAG. PARTICLE ULTRASONIC
ALTERNATIVE SEAL PUMP TEST (10.3.5.2) SEE PAGE 1, LINE 29
69
ISSUE STATUS
REVISION LOG DATE
70
REV.
BY
CHECKED
APPROVED
71
0
Issued for Supplier Input
2/8/08
ON
TKS
BE
72
1
Issued for Purchase
2/22/08
ON
TKS
BE
73
2
Supplier comment for AS-BUILT
7/1/09
PK
JS
0
74
REV
FLUID DATA (QUENCH, BUFFER AND BARRIER, LIQUID AND GAS)
8
11
2HPX9A
NUMBER REQUIRED:
BY PURCHASER
2
OF
FLOWSERVE
2
10
A2IS-4-0601
P.O. NUMBER:
CLIENT:
9
A2IS-4-0601
RFQ NUMBER:
1
DETROIT, MICHIGAN
0
INQUIRY NUMBER:
Note: This data sheet has been modified from that in the annex of API Standard 682, 3th Edition, September 2004.
MARATHON OIL COMPANY
CONTRACT: TAG ITEM NUMBER:
View more...
Comments