Ald Maintenance Link Failure Alarm Tutorial for Version 521
January 22, 2017 | Author: Rv Salazar | Category: N/A
Short Description
ALD ALARM TROUBLESHOOTING...
Description
TROUBLESHOOTING GUIDE
Prepared by: Russell Salazar FM Engineer 3G Mobily Project
ANTENNA LINE DEVICE COMPONENTS
RET ANTENNA
SMART BIAS TEE
REMOTE CONTROL UNIT
TOWER MOUNTED AMPLIFIER AISG 2.0 CABLE
ANTENNA LINE DEVICE SAMPLE SETs SET A
SET B
SET C
RET ANT
RET ANT
RET ANT
SM BT
R C U
JUMPER CABLES
R C U
JUMPER CABLES
JUMPER CABLES AISG CABLE
TMA
AISG CABLE
JUMPER CABLES
TMA
AISG CABLE
JUMPER CABLES
FEEDER CABLES FEEDER CABLES
FEEDER CABLES
JUMPER CABLES
JUMPER CABLES
JUMPER CABLES
WRFU
WRFU
WRFU
WRFU
WRFU
WRFU
0A
1A
2A
3A
4A
5A
ANTENNA LINE DEVICE GUIDE SET A RET ANT
THE ALD LINK IS ACTIVATED ONCE THE ALD POWER IS SWITCHED ON AT THE ANTENNA PORT ( RF UNIT )
MOD ANTENNAPORT—to set the ANT Port to ON/OFF. DSP ANTENNAPORT—to check the status of the configured ALD Power Switch
SM BT
R C U
ON
OFF
WRFU
WRFU
0A
1A
LST OR DSP ANTENNAPORT—to query the status of SMBT power port to RCU.
Normal Configuration: PORTS R0A –always ON on SN 0, 2, 4. PORTS ROB --always OFF on all SN.
ANTENNA LINE DEVICE GUIDE SET A RET ANT
CHECK CONNECTED ALD DEVICE/S ON ACTIVE PORT AND CONFIGURE OR ADD THE DEVICE/S. SMBT—not configurable.
RCU—need to be configured.
SCN ALD—to query the connected ALD devices.
SM BT
R C U
If you see the RCU’s serial number, it means ALD link is complete and the device can be added. Device Name = Null & Configure Status = not configured because the device is not yet configured or not yet added. ADD RET —to configure the connected ALD device/s. make sure add the device to the correct ant connector.
LST RET —to query configured ALD device/s.
ON
OFF
WRFU
WRFU
0A
1A
ANTENNA LINE DEVICE GUIDE SET A
CHECK THE FUNCTIONALITY OF THE CONFIGURED ALD DEVICE/S.
RET ANT LST OR DSP ANTENNAPORT—to test SMBT’s power switch function status and current consumption. SM BT
R C U
CLB ANT—to query the RCU’s motor function and if RCU is in position. Subunit is 1. MOD RETTILT—to query the RCU’s titling adjustment on RET antenna. DSP RETSUBUNIT—to query the actual configured antenna’s electrical tilt.
ON
OFF
WRFU
WRFU
0A
1A
ANTENNA LINE DEVICE GUIDE THE ALD LINK IS ACTIVATED ONCE THE ALD POWER IS SWITCHED ON AT THE ANTENNA PORT ( RF UNIT )
SET B RET ANT
MOD ANTENNAPORT—to set the ANT Port to ON/OFF.
R C U
DSP ANTENNA PORT —to check the status of the configured ALD Power Switch —to query the status of TMA power port to RCU. Normal Configuration: PORTS R0A –always ON on SN 0, 2, 4. PORTS R0B—always OFF on all SN.
TMA
WRFU
ON
OFF WRFU
0A
1A
ANTENNA LINE DEVICE GUIDE CHECK CONNECTED ALD DEVICES ON ACTIVE PORT AND CONFIGURE OR ADD THE DEVICE/S.
SET B RET ANT
NEED TO CONFIGURE BOTH RCU AND TMA. SCN ALD—to query the connected ALD devices. R C U
TMA
If you see the RCU’s & TMA’s serial number, it means ALD link is complete and the devices can be added. Note: TMA has two serial numbers. Device Name = Null & Configure Status = not configured because the device is not yet configured or not yet added.
ADD RET OR TMA—to configure the connected ALD device/s. make sure add the device to the correct ant connector. LST RET OR TMA—to query configured ALD device/s. AFTER ADDING YOU NEED TO RUN SCN COMMAND WRFU
ON
OFF WRFU
0A
1A
ANTENNA LINE DEVICE GUIDE SET B
CHECK THE FUNCTIONALITY OF THE CONFIGURED ALD DEVICE/S.
RET ANT MOD ANTENNAPORT—to test TMA’s power switch function.
R C U
DSP OR LIST ANTENNAPORT—to check TMA’s status and current consumption. CLB ANT—to query the RCU’s motor function and if RCU is in position.
TMA MOD RETTILT—to query the RCU’s titling adjustment on RET antenna. DSP RETSUBUNIT —to query the actual configured antenna’s electrical tilt.
WRFU
ON
OFF WRFU
0A
1A
ANTENNA LINE DEVICE GUIDE SET C RET ANT
THE ALD LINK IS ACTIVATED ONCE THE ALD POWER IS SWITCHED ON AT THE ANTENNA PORT ( RF UNIT )
MOD ANTENNAPORT—to set the ANT Port to ON/OFF.
DSP ANTENNAPORT—to check the status of the configured ALD Power Switch —to query the status of TMA power port to RCU (inside antenna). Normal Configuration: PORTS R0A –always ON on SN 0, 2,4. PORTS R0B—always OFF on all SN.
TMA
ON
OFF
WRFU
WRFU
0A
1A
ANTENNA LINE DEVICE GUIDE SET C RET ANT
CHECK CONNECTED ALD DEVICES ON ACTIVE PORT AND CONFIGURE OR ADD THE DEVICE/S. NEED TO CONFIGURE BOTH RCU AND TMA. SCN ALD—to query the connected ALD devices. If you see the RCU’s & TMA’s serial number, it means ALD link is complete and the devices can be added. Note: TMA has two serial numbers. Device Name = Null & Configure Status = not configured because the device is not yet configured or not yet added.
TMA
ADD TMA—to configure the connected ALD device/s. make sure add the device to the correct ant connector. DSP RET/TMA—to query configured ALD device/s.
ON
OFF
WRFU
WRFU
0A
1A
ANTENNA LINE DEVICE GUIDE SET C
CHECK THE FUNCTIONALITY OF THE CONFIGURED ALD DEVICE/S.
RET ANT MOD ANTENNAPORT—to test TMA’s power switch function. DSP ANTENNAPORT—to check TMA’s status and current consumption. CLB ANT—to query the RCU’s motor function and if RCU is in position. TMA
MOD RETTILT—to query the RCU’s titling adjustment on RET antenna. DSP RETSUBUNIT—to query the actual configured antenna’s electrical tilt.
ON
OFF
WRFU
WRFU
0A
1A
click
PRESS BROWSE ALARM TO SEE ALARM DETAILS
DOUBLE CLICK ALARM TO SEE DETAILED INFORMATION.
DOUBLE CLICK
Click Solution tab to get more Help on troubleshooting procedure.
CHECK AISG CABLE FUNCTIONALITY
HOW TO CHANGE AISG CABLE
1. SET ALDPWRSW to OFF 2. Replace AISG cable. 3. SET ALDPWRSW to ON
USE MULTIMETER TO CHECK THE CONNECTIVITY OF EACH PIN PINS 1, 3, 5, 6, 7 SHORTED = CABLE is OK If one or more of the PINS 1, 3, 5, 6, 7OPEN = CABLE is defective
HOW TO CHANGE/REMOVE RCU 1. 2. 3. 4. 5. 6. 7. 8.
RMV RET and then SCN ALD to verify the ALD is removed MOD ANTENNAPORT to OFF. Remove RCU device and cable. Install RCU device and cable. MOD ANTENNAPORT to ON. SCN ALD to query successful replacement.. ADD RET to configure the new RCU. LST RET to view if configured. DLD RETCFGDATA to load the configuration of RCU if new RCU is used.
ALDCFG is located on the NodeB software.
C:\Desktop\ KA_742265_1710-2170.bin 0
Computer IP address
admin
admin
HOW TO CHANGE SMBT/TMA 1. 2. 3. 4. 5. 6. 7. 8. 9.
BLK BRD ( N0A=SN 0, N2A=SN 2, N4A-SN 4) MOD TXBRANCH to OFF. MOD ANTENNAPORT to OFF. Remove SMBT/TMA devices and cables. Install SMBT/TMA devices and cables. MOD TXBRANCH to ON. MOD ANTENNAPORT to ON. UBL BRD. SCN ALD to query successful replacement. ADD TMA to configure new TMA device. LST TMA to query successful configuration.
1. If the RCU’s serial number is null or empty after executing the SCN ALD command, first try to reconfigure or add the RCU’s serial number thru ADD RET command and manually encoding the serial number and vendor code, before changing the RCU device.
2. Try to remove configured device/s first and then reconfigure/add the device/s after.
SAMPLE device name only
3.1 3. Ifcheck the Power if the devices Supply Switch are properly Run Status configured SMBT/TMA to the can not be turned correct port first ON, before try tochecking reset ALD the Power physical Switch first using RST ALDPWRSW connections ( feeder swapped command. ) of the cables to the Or trythe resetting the corresponding WRFU 3.2devices. Try resetting corresponding WRFU board.. board. SM BT
SM BT
SM BT
TMA
TMA
TMA
WRFU
WRFU
WRFU
WRFU
WRFU
WRFU
WRFU
WRFU
WRFU
WRFU
WRFU
WRFU
0A
1A
0A
1A
0A
1A
2A
3A
2A
3A
2A
3A
Feeder swapped
Feeder swapped
4. For ALD Current Out of Range Alarm, first check any loosed connections on ALD line especially the connectors from RF unitJumper cable to Jumper-Feeder connectors, Feeder-Jumper connectors JumperTMA/SMBT connectors. And then, SET ALDPWRSW to OFF and then ON. Also check that the current consumption is within the current limit set.
5. For MOTOR FAULT ERROR alarm, check also the Edowntilt gear part of the antenna where the RCU is connected.
%%DSP RETSUBUNIT: MODE= SUBUNIT, DEVICE = 0, 5. For ALD LINKOPM IS BROKEN alarm, test SUBUNIT=“1";%% your AISG CABLE with the use of a RETCODE = 0 Succeed.
multimeter tool. Carefully check the Antenna pins Tilt 1, 3, 5, 6 & 7, they should be ------------shorted end to end.
Device No. = 0 Site No. = NULL Sector No. = NULL 6. For RET ANT NOT CALIBRATED Cabinet No. = 0 alarm, just execute Subrack No. = 4the CALIB ANT and SET ANTTILT commands. Antenna Connector No. = R0A Device Type = SINGLE_RET Configured Tilt(0.1 degree) = 60 Current Tilt(0.1 degree) = 60
7. RET Antenna Running Data and Configuration Mismatch alarm, make sure the configured and current tilt is the same. Check using DSP ANTTILT.
8. For TMA set-up, If you cannot configure the device on normal Ant Port, try to configure the device on the other Ant Port. Example, Port 0A to 1A, Port 2A to 3A and Port 4A to 5A, which means you have to set the ALDPWRSW of Port 0A to OFF and turn Port 1A to ON before you can configure the RCU or TMA to port 1A. TMA
TMA
ON
OFF
OFF WRFU
WRFU
0A
1A
0A
1A
WRFU
WRFU
NORMAL CONFIG
ON
ALTERNATIVE CONFIG
9. If you faced system busy on running the following commands, it may be because other related command is running or a HW problem on SMBT or RCU. 1. DSP RET OR TMA 2. DSP RETTILT 3. SCN ALD
Make sure no other command is running or take a little time before running the next related command, like, After ADD RET, don’t immediately run LST RET or DSP RETTILT.
View more...