Alarm & Status
Short Description
iPaso Alarm & status...
Description
Alarm & Status
iPASOLINK Introduction
45
ODU Alarm and Status Indication TXPWR ALM TX INPUT ALM
Category Alarm Alarm
Descriptions The TX PWR is lower than 3 dB. The TX IF signal become out of range from -29 dBm ± 5 dB. The reception level become lower than -72dBm ~ -94dBm level.(It depends on the modulation system and bit rates).
Severity MJ MJ
RXLEV ALM
Alarm
ODU CPU / Cable Open
Alarm
CPU of ODU is faulty or IF CABLE between IDU - ODU of ODU is broken or is not connected.
MJ
MUTE STATUS
Status
Indicates the control status of the ODU TX power output. When the TX power is set to Mute, Status is issued.
-
LO REF
Alarm
Loss of Ref LO signal of ODU.
MN
TX SW Status
Status
Radio interface TX SW usage state in 1+1 HS Redundant configuration
-
ODU ALM
Alarm
Indicates one of the TXPWR ALM, ODU PS ALM, APC ALM, TPC ALM, ODU SELF CHECK ALM occurrence
MJ
ODU TOTAL ALM
Alarm
Indicates one of the TXPWR ALM, TX INPUT ALM, RX Level ALM, ODU CPU/CABLE OPEN ALM, LOREF, ODU ALM occurrence.
Highest severity will be displayed
ATPC Power Mode
Status
ATPC control signal fault (90sec) as well as MAX Power continuation 90sec
-
ODU TYPE MISMATCH
Alarm
Indicate connected ODU type is not supported at iPASOLINK system, or ODU type cannot use in provisioned modulation setting.
MJ
Alarm Status
ALM in a case of Power supply interruption to ODU. Status indication of the protection switch for ODU power supplies
MJ -
ODU PS ALM ODUPS SET STATUS
iPASOLINK Introduction
MJ
46
Modem Alarm and Status Indication
Category
Descriptions
Severity
Unequipped (MODEM-A)
Alarm
Reserved and installed optional package is removed from optional slot.
MJ
Type Mismatch(MODEM-A)
Alarm
The equipped type of interface is different from configured type.
MJ
Communication FAIL(MODEM-A) Alarm
Communication failure of equipment internal control communication.
MJ
Module(MODEM-A)
Alarm
Equipment fault
MJ
BUS ERROR TX
Alarm
Data communication BUS failure condition in TX direction from STM-1 Card.
MJ
BUS ERROR RX
Alarm
Data communication BUS failure condition in RX direction from STM-1 Card.
MJ
RXSW STATUS
Status
Radio interface RX SW usage state in Redundant configuration
-
LOSS OF FRAME
Alarm
Loss of Frame at radio side.
MJ
FRAME ID
Alarm
Frame ID (route differentiation ID)
MJ
HIBER ALM
Alarm
Radio signal degradation (High BER threshold detection). (Threshold :1E-3/1E-4/1E-5)
MJ
LOBER ALM
Alarm
Radio signal degradation (Low BER threshold detection). (Threshold. :1E-6/1E-7/1E-8/1E-9)
MN
EARLY WARNING
Alarm
Radio signal degradation (Early Warning threshold detection). (Threshold :1E-9)
MN
MOD
Alarm
Indicates the operating status of the MOD. When any failure occurs in the modulator section, “Alarm” is issued.
MJ
IF CABLE SHORT
Alarm
IF cable between IDU - ODU is in short condition.
MJ
INPHASE.
Status
In - Phase indicates the received signal DADE status between No.1 and No.2 MODEM interfaces are in Phase condition. In this condition, hitless switch over is available.
-
L2SYNC LOSS
Alarm
Loss of frame synchronization of GFP frames on MODEM port.
MJ
RDI
Alarm
RDI indication reception alarm on MODEM port
MJ
UAE.
Alarm
UAE alarm. Indicates the occurrence of an Unavailable state.
MN
TDM/AMR Range Mismatch
Alarm
Mismatch condition when the mapping number of E1 channels are different between TX and RX modem ports or mismatch condition of selected RX AMR modulation range and TX AMR modulation range.
MJ
TX SW Reverse Request
Status
TXSW request signal receiving condition from the opposite station:
-
TX SW Lock in Status
Status
TXSW Lockin state
-
Unlocked
Alarm
Wireless synchronization status of the local side.
MJ
MODEM PS OFF
Status
Indicate power off condition of power switch which is in front of MODEM-A card.
-
iPASOLINK Introduction
47
STM-1 Alarm and Status Indication
Category
Descriptions
Severity
Unequipped (STM1-A)
Alarm
Reserved and installed optional package is removed from optional slot.
MJ
Type Mismatch(STM1-A)
Alarm
The equipped type of interface is different from configured type.
MJ
Communication FAIL(STM1-A)
Alarm
Communication failure of equipment internal control communication.
MJ
Module(STM1-A)
Alarm
Equipment fault
MJ
BUS ERROR TX
Alarm
Data communication BUS failure condition in TX direction from STM-1 Card.
MJ
BUS ERROR RX
Alarm
Data communication BUS failure condition in RX direction from STM-1 Card.
MJ
SNCP PPS-FAIL
Alarm.
SNCP Path Protection Failure
MJ
SNCP Protection Status
Status
SNCP Path Protection Status indication which indicates [FS, SF, SD, MS, NR] condition.
-
APS Protection Status
Status
APS Line Protection Status indication which indicates {FS,SF,SD,MS,NR} condition.
-
APS Lock-in Status
Status
APS protection Lock-in Condition.
-
SFP_Type Mismatch (STM1)
Alarm
Mismatch between SFP on LCT and installed SFP.
MJ
SFP Unequipped (STM1)
Alarm
A SFP is removed.
MJ
STM-1LOS
Alarm
LOS detection on STM-1 Optical port.
MJ
STM-1 TF
Alarm
Transmit Failure detection on STM-1 optical port.
MJ
RS LOF
Alarm
SDH Frame synchronization lost in RS (Regenerator Section) on STM-1 port.
MJ
RS TIM
Alarm
Trace Identifier Mismatch detected in RS (Regenerator Section) on STM-1 port.
MJ
RS EXC
Alarm
B1 Byte error occurrence in RS (Regenerator Section) on STM-1 port.
MJ
RS DEG
Alarm
B1 byte error in RS (Regenerator Section) (RS - Degraded) on STM-1 port.
MN
MS AIS
Alarm
AIS detection in MS (Multiplex Section) on STM-1 port.
MJ
MS RDI
Alarm
Remote Defect Indication reception in MS (Multiplex Section) on STM-1 port.
MJ
AU AIS
Alarm
AIS detection in AU (Administrative Unit) on STM-1 port.
MJ
iPASOLINK Introduction
48
STM-1 Alarm and Status Indication
Category
Descriptions
Severity
AU LOP
Alarm
Loss of AU pointer happens on STM-1 port.
MJ
HP UNEQ
Alarm
HOP (Higher Order Path) Unequipped occurrence on STM-1 port.
MJ
HP TIM
Alarm
HOP (Higher Order Path) Trace Identifier mismatch occurrence on STM-1 port.
MJ
HP-PLM
Alarm
Payload Label Mismatch occurrence in HOP (Higher Order Path) on STM-1 port.
MJ
HP-RDI
Alarm
RDI (Remote Defect Indication) reception in HOP (Higher Order Path) on STM-1 port.
MJ
HP-LOM
Alarm
Loss of Multi-Frame on STM-1 port.
MJ
TU -AIS
Alarm
In TU (Tributary Unit), AIS detection on STM-1 port.
MJ
TU -LOP
Alarm
Loss of TU Pointer on STM-1 port.
MJ
LP -UNEQ.
Alarm
LP (Lower Order Path) Unequipped occurrence on STM-1 port.
MJ
LP – RDI
Alarm
Remote Defect Indicate reception by an LP (Lower Order Path) on STM-1 port.
MJ
LP – PLM
Alarm
Payload Label Mismatch Failure occurrence by an LP (Lower Order Path) on STM-1 port.
MJ
ALS
Status
Indication of automatic laser shutdown condition at STM-1 optical port.
-
RS UAS Status
Status
UAS status indication on STM port (Repeater Section)
-
STM-1 AIS Generated
Status
AIS generation condition on STM port.
-
PJE
Status
Pointer justification Event indication at STM port.
-
iPASOLINK Introduction
49
16E1 alarm and Status Indication
Category
Descriptions
Severity
Unequipped (16E1)
Alarm
Reserved and installed optional package is removed from optional slot.
MJ
Type Mismatch(16E1)
Alarm
The equipped type of interface is different from configured type.
MJ
Communication FAIL(16E1)
Alarm
Communication failure of equipment internal control communication.
MJ
Module(16E1)
Alarm
Equipment fault
MJ
BUS ERROR TX
Alarm
Data communication BUS failure condition in TX direction from STM-1 Card.
MJ
BUS ERROR RX
Alarm
Data communication BUS failure condition in RX direction from STM-1 Card.
MJ
E1 LOS
Alarm
No signal input on E1 port
MJ
E1 AIS
Status
ALARM/Status category can change according to " AIS Received Condition Setting
MJ / -
Usage Error
Alarm
Unused E1 CH input signal detection.
MN
E1 AIS Generated
Status
AIS generation condition on every E1 Channels.
-
iPASOLINK Introduction
50
AUX-A Option Card
Indication
Category
Descriptions
Severity
Unequipped (AUX-A)
Alarm
Reserved and installed optional package is removed from optional slot.
MJ
Type Mismatch(AUX-A)
Alarm
The equipped type of interface is different from configured type.
MJ
Communication FAIL(AUX-A)
Alarm
Communication failure of equipment internal control communication.
MJ
Module(AUX-A)
Alarm
Equipment fault
MJ
BUS ERROR TX
Alarm
Data communication BUS failure condition in TX direction from STM-1 Card.
MJ
BUS ERROR RX
Alarm
Data communication BUS failure condition in RX direction from STM-1 Card.
MJ
Item Name (Input-x) Item Name (Cluster-x)
Status/ Alarm
HKA Status Indication {Alarm, Normal} for every HKA input.
- or Severity selectable
Item Name (Output-x)
Status
HKC Status {Alarm, Normal} for every HKC output.
-
iPASOLINK Introduction
51
GbE-A option card Indication
Category
Descriptions
Severity
Unequipped (GBE-A)
Alarm
Reserved and installed optional package is removed from optional slot.
MJ
Type Mismatch(GBEA)
Alarm
The equipped type of interface is different from configured type.
MJ
Communication FAIL(GBE-A)
Alarm
Communication failure of equipment internal control communication.
MJ
Module(GBE-A)
Alarm
Equipment fault
MJ
BUS ERROR TX
Alarm
Data communication BUS failure condition in TX direction from STM-1 Card..
MJ
BUS ERROR RX
Alarm
Data communication BUS failure condition in RX direction from STM-1 Card..
MJ
SFP_Type Mismatch (ETH)
Alarm
Mismatch between SFP on LCT and installed SFP.
MJ
SFP Unequipped (ETH)
Alarm
A SFP is removed.
MJ
LAN LINK
Alarm
LINK of the LAN Port is disconnected.
MJ
Speed & Duplex
Status
LAN Port setting (Speed&Duplex)
-
iPASOLINK Introduction
52
Equipment Common alarm and Status-1 Indication
Category
Descriptions
Severity
MODULE (Main Board)
Alarm
Equipment fault
MJ
BUS ERROR
Alarm
Data communication BUS failure condition.
MJ
Unequipped (PS)
Alarm
Installed Power Supply Module is removed from PS slot.
MJ
Power Supply
Alarm
Alarm in case of power failure.
MJ
FAN Fail
Alarm
FAN failure
MJ
Unequipped (FAN)
Alarm
Installed FAN Module is removed from FAN slot.
MJ
Unequipped (CLK2M)
Alarm
Installed CLK2M Module is removed from Main Card.
MJ
Type Mismatch (CLK2M)
Alarm
The equipped type of interface is different from configured type.
MJ
IDU CPU Alarm
Alarm.
IDU CPU Alarm
MN
Memory Failure
Alarm
Detection of memory failure
MJ
USB Failure
Alarm
USB memory failure indication
MJ
Temperature
Alarm
The temperature is over the threshold
MN
Maintenance
Status
Maintenance declaration.
-
CLK FAIL
Alarm
Reference Clock Failed.
MN
CLK Drift
Alarm
Reference Clock source Frequency drift condition
MN
LTI
Alarm
Loss of all incoming timing source
MJ
CLK Status Changed
Status
Reference clock change status (1) (Locked Ref1) (2) (Locked Ref2) (3) (Locked Ref3) (4) Holdover (5) Freerun
-
SSM FAIL
Alarm
Received Sync Status Message value is in unstable condition.
MN
Quality Level
Status
Received quality level condition of each timing source.
-
Squelch
Status
The condition of External CLK Output is in squelch condition.
-
iPASOLINK Introduction
53
Equipment common Alarm and Status -2 Indication
Category
Descriptions
Severity
EXT CLK Condition
Status
Condition level of External CLK output.
-
EXT CLK LOS
Alarm
Loss of Signal condition of External clock input.
MN
EXT CLK AIS
Alarm
AIS (Alarm Indication Signal) condition of External Clock input.
MN
EXT CLK LOF
Alarm
Loss of frame condition of External Clock input.
MN
EXT CLK Loop
Alarm
Indication of EXTERNAL clock input is used as EXTERNAL clock output.
MJ
Item Name (Input-x) Item Name (Cluster-x)
Status/ Alarm
HKA Status Indication {Alarm, Normal} for every HKA input.
- or Severity selectable
Item Name (Output-x)
Status
HKC Status {Alarm, Normal} for every HKC output.
-
E1 LOS
Alarm
No signal input on E1 port
MJ
E1 AIS
Status
PDH – AIS ALARM/Status category can change according to " AIS Received Condition Setting
MJ / -
Usage Error
Alarm
Unused E1 CH input signal detection.
MN
E1 AIS Generated
Status
AIS generation condition on every E1 Channels.
-
ETH LOS
Alarm
LOS detection at Optical Ethernet port.
MJ
ETH TF
Alarm
Transmit Fail detection at Optical Ethernet port.
MJ
SFP_Type Mismatch (ETH)
Alarm
Mismatch between SFP on LCT and installed SFP.
MJ
SFP Unequipped (ETH)
Alarm
A SFP is removed.
MJ
LAN LINK
Alarm
LINK of the LAN Port is disconnected.
MJ
Speed & Duplex
Status
LAN Port setting (Speed&Duplex)
-
ETH-OAM LOC
Alarm
ETH-OAM Mismerge
Alarm
Ether OAM Mismatch Detection notice.
MN
ETH-OAM Unexpected Period
Alarm
Ether OAM Unexpected MEP and Ether OAM Unexpected Period detection notice
MN
ETH-OAM RDI
Alarm
Ether OAM RDI reception detection notice
MJ
MJ
iPASOLINK Introduction
54
Equipment common Alarm and Status -3 Indication
Category
Descriptions
Severity
RSTP New Root Bridge Detect
Status
The notice in which new RootBridge was detected at the time of SpanningTree processing
-
RSTP Topology Changed
Status
The notice in which a Topology change was detected at the time of SpanningTree processing
-
RSTP Protocol Migration
Status
The notice which received a Bridge protocol Data Units different in classification of RSTP/STP at the time of SpanningTree processing
-
RSTP Invalid BPDU Received
Status
Invalid BPDU message at the time of SpanningTree processing
-
LLF Message Timeout
Status
Loss of a conditional signaling in which the LLF control signal should be received continuously from the opposite radio equipment.
LLF
Status
LLF force a LINKDOWN status. The Ethernet port under "edge" mode becomes LINKDOWN.
The highest Severity will be reported
IDU TOTAL ALM
Alarm
IDU TOTAL ALM
Total FDB Full
Status
The number of DynamicEntryDynamic Entry in L2Switch has reached the maximum number.
FDB Full
Status
FDB Full indication specified per VLAN basis.
iPASOLINK Introduction
55
View more...
Comments