Adani Kone 375 Resolve 500 Diagram
October 4, 2022 | Author: Anonymous | Category: N/A
Short Description
Download Adani Kone 375 Resolve 500 Diagram...
Description
1
A
B
n C o i t a r o p r o C E N O K 1 0 0
2
3
4
1
HOISTING MOTOR
1:T
THERMISTORS
6
ENCODER
10
FAN
10:T
THERMAL CONTACT
11
BRAKE SOLENOID
13
SLACK ROPE CONTACT
14
STOP SWITCH IN MACHINERY
18
FIRE INDICATION IN MACHINE ROOM
19:4
MAINS FUSE
20
MAIN SWITCH UNIT
22
OVERSPEED GOVERNOR CONTACT
25
SEISMIC DEVICE(OPTIONAL)
26
OVERSPEED GOVERNOR CONTACT FOR COUNTERWEIGHT
30
DOOR ZONE SWITCH
31
CAR CALL BUTTONS
32
I/O-BOARD LCECOB
32:1
EXPANSION BOARD LCECEB
33
ATTENDANT SWITCH
33:B
ATTENDANT BY-PASS
33:N
ATTENDANT DOWN
33:U
ATTENDANT UP
34
DOOR OPEN BUTTON
34:S
DOOR CLOSE BUTTON
34:E
DOOR EXTENSION TIME
35
PRIORITY DRIVE SWITCH(OPTIOANL)
36
SWITCH FOR CAR LIGHTING
5
6
37
2 D ) C ( t h g i r y p o C
E
4 A
F
38
SWITCH FOR CAR FAN LOCKING SWITCH(OPTIOANL)
39
ALARM BUTTON
41
STOP SWITCH ON CAR ROOF
42:DS
SWITCH FOR INSPECTION DRIVE
42:U
INSPECTION BUTTON "UP"
42:N
INSPECTION BUTTON "DOWN"
42:RB
INSPECTION BUTTON "RUN"
43
CAR FAN
44
CAR LIGHTING
44:1-2
EMERGENCY LIGHTING
45
SOCKET ON CAR ROOF
51
FINAL LIMIT SWITCH IN CAR
52
SAFETY GEAR CONTACT
53
SLACK ROPE CONTACT
57
EMERGENCY EXIT CONTACT(OPTIONAL)
61:U 61:N
IMPULSE SWITCH "UP" IMPULSE SWITCH "DOWN"
64
LOAD WEIGHING DEVICE
65
ALARM BUZZER ON CAR ROOF
66
OUT OF SERVICE SWITCH
71
FIREMANS SWITCH
77:U
DECELERATION SWITCH "UP"
77:N
DECELERATION SWITCH "DOWN"
77:S
SYNCHRONIZATION SWITCH
G
Designed by
Checked by
MES
I ss ue
Change description
H
Department D a te
D es . b y
Appr. by
MES
Date
EN
Product Code
Approved by
10/1/2006
PD
Language
RESOLVE 500
SP
POSITION NUMBER TABLE KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM CHENNAI-600 095
Sales ref. no.
Drawing Number
972500164E00
I ss u e
00
Pa ge
1/3
1
A
B
n C o i t a r o p r o C E N O K 1 0 0
2
3
4
82
SAFETY EDGE CONTACT
84
DOOR OPERATOR
85
DOOR MOTOR
87
CAR DOOR CONTACT
88
DOOR PHOTOCELL, TRANSMITTER
89
DOOR PHOTOCELL, RECEIVER
90
PHOTOCELL DEVICE
93:N
ATTENDANT DOWN
93:U
ATTENDANT UP
96:S
GONG
97
ALARM RECEIVED LIGHT
98
LOUDSPEAKER FOR ELEVATOR SPEECH UNIT
99
OVERLOAD INDICATION
100
INTERCOM DEVICE
102
PB,DC CALL BUTTONS
103
DOWN CALL BUTTONS
104
UP CALL BUTTONS
105
FEB CALL BUTTONS
106
FET CALL BUTTONS
112
STOP BUTTON
113
PRL H
115
PRL L
116
OUT OF SERVICE SWITCH
117
LOCKING SWITCH
120
CONCEALED DOOR CONTACT
121
SHAFT DOOR CONTACT
122
SHAFT DOOR LOCK CONTACT
123
TENSION WEIGHT CONTACT(OPTIONAL)
5
6
125:1-2
2 D ) C ( t h g i r y p o C
E
4 A
F
G
126
BUFFER CONTACT SAFETY GEAR CONTACT FOR COUNTERWEIGHT(OPTIONAL)
127
OVERSPEED GOVERNOR CONTACT
133
FIREMANS SWITCH
137
BUTTON FOR SHAFT LIGHT
139
ALARM BELL
157
SHAFT LIGHTING
158
SOCKET IN SHAFT PIT
161
IN USE LIGHT(OPTIONAL)
166
OUT OF SERVICE LIGHT(OPTIONAL)
176
CAR POS. INDICATOR AT FLOORS
190
DERAILMENT CONTACT(OPTIONAL)
193
FIRE DETECTION AT LANDINGS
197
FLOOR BOARD LCEFCB
198
FLOOR BOARD LCEFOB
201
MAIN CONTACTOR
209 227
BRAKE CONTACTOR EMERGENCY BATTERY
228
REMOTE ALARM BOARD LCERAL
236
EARTH FAULT RELAY
239
CONTROL CURRENT TRANSFORMER
242
BRAKE TRANSFORMER
245
DOOR TRANSFORMER
267
STOP BUTTON
270
SWITCH FOR RECALL DRIVE
270:U
RECALL DRIVE BUTTON "UP"
270:N
RECALL DRIVE BUTTON "DOWN"
270:RB
RECALL DRIVE BUTTON "RUN"
279
DOOR ZONE INDICATION
298
FUSE SWITCH Designed by
Checked by
MES
I ss ue
Change description
H
Department D a te
D es . b y
Appr. by
EN
MES
Date
Product Code
Approved by
10/1/2006
PD
Language
SP
RESOLVE 500
POSITION NUMBER TABLE KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM CHENNAI-600 095
Sales ref. no.
Drawing Number
972500164E00
I ss u e
00
Pa ge
2/3
1
A
B
n C o i t a r o p r o C E N O K 1 0 0 2 D ) C ( t h g i r y p o C
2
306
BRAKING RESISTOR
367
I/O CONNECTION BOX
3
4
372
SWITCH MODULE
375
CPU-BOARD LCECPU
379
SAFETY CIRCUIT BOARD LCE230/LCEADO
385
DRIVE MODULE
387
FILTER MODULE
388
BRAKE CONTROL UNIT
390
POWER MODULE
722
EXPANSION BOARD LCEOPT
723
POWER SUPPLY BOARD
731
GATEWAY BOARD LCEGTW
732
CAN-BOARD LCECAN
766
ELEVATOR SPEECH UNIT
806
CAR CONTROLLER BOARD LCECCBS
806:E
EXPANSION BOARD LCECCEB
K443
DOOR ZONE CONTACTOR
K486
SPEED MEASUREMENT CONTACTOR
K487
SUPERVISORY CONTACTOR
K553
ACCURATE LEVELLING RELAY
5
6
E
4 A
F
G
Designed by
Checked by
MES
I ss ue
Change description
Department D a te
D es . b y
Appr. by
PD
H
Language
MES
Date
EN
Product Code
Approved by
10/1/2006
RESOLVE 500
SP
POSITION NUMBER TABLE KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM CHENNAI-600 095
Sales ref. no.
Drawing Number
972500164E00
I ss u e
00
Pa ge
3/3
1
2
3
4
5
6
CONTROL PANEL A
379 LCEADOS/ 230S
XM1 1
IF NO KRD IN JOB
3
KM778949G04-R
B
n C o i t a r o p r o C E N O K 1 0 0 2 D ) C ( t h g i r y p o C
XM4 1 3
OVERSPEED GOVERNOR CONTACT
XM3 1 3
22 1 2
21
1 2
KM769346GXX
22
GN/YE
PE
GN/YE
E
4 A
F
G
Designed by
MES
I ss u e
Change description
H
Department Da te
D es. b y
Appr. by
PD
Language
Checked by
Date
10/1/2006
MES
EN
Approved by
Product Code
SP
RESOLVE 500
SAFETY SWITCHES AND OVERSPEED GOVERNORS KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM CHENNAI-600 095
Sales ref. no.
Drawing Number
Is su e
972500164E03 00
P age
1/2
MACHINE ROOM WIRING DIAGRAM
1
2
3
4
5
6
CONTROL PANEL A
379 LCEADOS/ 230S
XM1 1
TO SC/20 IN KRD TO SC/30 IN KRD
3
B
n C o i t a r o p r o C E N O K 1 0 0 2 D ) C ( t h g i r y p o C
XM4 1 3
OVERSPEED GOVERNOR CONTACT
XM3 1 3
22 KM769346GXX
1 2
21
1 2
22
GN/YE
PE
GN/YE
E
4 A
F
G
Designed by
MES
I ss u e
Change description
H
Department Da te
D es. b y
Appr. by
PD
Language
Checked by
Date
10/1/2006
MES
EN
Approved by
Product Code
SP
RESOLVE 500
SAFETY SWITCHES AND OVERSPEED GOVERNORS KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM CHENNAI-600 095
WITH KONE RESCUE DEVICE (KRD) Sales ref. no.
Drawing Number
972500164E03
Is su e
P age
00
2/2
MACHINE ROOM WIRING DIAGRAM
1 M R A L A
T I P
A
2 D S R R F O / O D D I F
3
4
5
6
5 8 4 S R
B
n C o i t a r o p r o C E N O K 1 0 0 2 D ) C ( t h g i r y p o C
X X G 3 8 1 0 2 5 2 7 9
X X G 8 1 1 0 2 5 2 7 9
X X G 2 4 7 2 3 7 M K
X X G 9 9 1 0 2 5 2 7 9
X X G 9 3 6 1 8 7 M K
E
4 A
F
G
T I P
M R A L A
K C D O R L F / E D T I A F G
5 8 4 S R
Designed by
I ss u e
Change description
H
Checked by
MES
EN
Approved by
Product Code
SP
RESOLVE 500
Department Da te
D es. b y
Appr. by
Language
MES PD
Date
10/1/2006
CEILING OF LIFT WELL KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM CHENNAI-600 095
Sales ref. no.
Drawing Number
Is su e
972500164E05 00
P age
1/4
972500164E05
CHENNAI 600 095
SHAFT WIRING DIAGRAM
1
A
T M I R P A L A
2 S R O O D
D R F / D I F
3
4
5
6
5 8 4 S R
E Y N G
A-SIDE SHAFT DOOR AND LOCK CONTACTS
2 5 3
P122
2 2 1 P
2
GNYE
PE
122:n
5 GNYE 3 E Y N G
B
LANDING PUSH BOX A-SIDE XS1 n C o i t a r o p r o C E N O K 1 0 0 2 D ) C ( t h g i r y p o C
XS2
XF1 FLOOR BOARD LCEFCB 1 +24V 197:n +24V 2 2 GND Up lamp/IUL 3 3 common Up call 4 4 RS485 Down lamp 5 5 Roll call Down call 6 6 RS485 common XF3 2 OSS 3 common A B XF4 1 +24V DOORS 2 OSI/HSL lamp 1
1
1
1
2
2
2
3
3
4
4
4
5
5
5
6
6
6
3
972520098G01
103:n
1 +24V 2 GND 3 common 4 RS485
E
5 Roll call 6 RS485
4 A
HALL LANTERN GONG +24 V
1
XF(A)2
1
1
1
2
2
3
3
2
2
3
3
4
4
4
4
Common 5
5
5
5
Chip select Clock Data
KM713810G01
176
F
G
M R T A I L P A
D R F / D I F
R O O D
5 8 4 S R
Designed by
I ss u e
Change description
H
Department Da te
D es. b y
Appr. by
PD
Date
10/8/2005
SERVED TOP FLOOR KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM
Language
Checked by
MES
MES
EN
Approved by
Product Code
SP
RESOLVE 500
A-SIDE
Sales ref. no.
Drawing Number
Is su e
00
P age
97 2500 164 E05
CHENNAI 600 095
2/4
SHAFT WIRING DIAGRAM
1
A
T M I R P A L A
2 S R O O D
D R F / D I F
3
4
5
6
5 8 4 S R
A-SIDE SHAFT DOOR AND LOCK CONTACTS P122 2
XS1
* 0 G 6 0 8 3 1 7
* 0 G 5 8 7 6 1 8
122:n
LANDING PUSH BOX
A-SIDE n C o i t a r o p r o C * * E 0 0 G N G 2 O 3 6 K 8 3 7 8 6 1 6 0 1 7 8 0 2 D ) C ( t h g i r y p o C
PE
5 GNYE 3
E Y N G
B
GNYE
XS2
XF1 FLOOR BOARD LCEFCB 1 +24V 197:n +24V 2 2 GND Up lamp/IUL 3 3 common Up call 4 4 RS485 Down lamp 5 5 Roll call Down call 6 6 RS485 common XF3 2 OSS 3 common A B XF4 1 +24V DOORS 2 OSI/HSL lamp 1
1
1
1
2
2
2
3
3
4
4
4
5
5
5
6
6
6
3
972520098G01
104:n
103:n
1 +24V 2 GND 3 common 4 RS485
E
5 Roll call 6 RS485
4 A
HALL LANTERN GONG +24 V Chip select
1
XF(A)2
2
1 2 KM713810G01
1
1
2
2
3
3
3
3
4
4
4
4
Common 5
5
5
5
Clock Data
176
F
G
M R T A I L P A
D R F / D I F
R O O D
5 8 4 S R
Designed by
I ss u e
Change description
H
Checked by
MES
EN
Approved by
Product Code
SP
RESOLVE 500
Department Da te
D es. b y
Appr. by
Language
MES Date
10/1/2006
PD
SERVED INTERMEDIATE FLOORS A-SIDE KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM
FL OO OOR S 31 -0 -02 Sales ref. no.
Drawing Number
Is su e
P age
3/4
972500164E05 00
CHENNAI 600 095
SHAFT WIRING DIAGRAM
1 T I P
A
2 S R O O D
D R F / D I F
3
4
5
6
ALARM BELL
5 8 4 S R
139
A-SIDE SHAFT DOOR AND LOCK CONTACTS P122 2 GNYE
GNYE
PE
122:n
5 GNYE 3
B
1 2
133 FRD/FID
LANDING PUSH BOX
A-SIDE XS1 n C o i t a r o p r o C * E 0 N G O 3 K 8 7 1 6 0 1 8 0 2 D ) C ( t h g i r y p o C
XS2
E
XF1 FLOOR BOARD LCEFCB 1 +24V 197:n +24V 2 2 GND Up lamp/IUL 3 3 common Up call 4 4 RS485 Down lamp 5 5 Roll call Down call 6 6 RS485 common XF3 2 OSS 3 common A B XF4 1 +24V DOORS 2 OSI/HSL lamp 1
1
1
2
2
2
3
3
4
4
4
5
5
5
6
6
6
3
972520098G01
104:n
1 +24V 2 GND
4
3 common 4 RS485
6
5 Roll call 6 RS485
HALL LANTERN GONG
713863G01
4 A
1
+24 V Chip select
1
XF(A)2
1 2
2
KM713810G01
1
1
2
2
3
3
3
3
4
4
4
4
Common 5
5
5
5
Clock Data
176
F
G
T I P
Designed by
MES
I ss u e
Change description
H
Department Da te
D es. b y
Appr. by
Language
Checked by
Date
10/1/2006
PD
MES
EN
Approved by
Product Code
SP
RESOLVE 500
SERVED FIRST FLOOR A-SIDE KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM
01 Sales ref. no.
FLOOR Drawing Number
Is su e
P age
CHENNAI-600 095
SHAFT WIRING DIAGRAM
972500164E05
00
4/4
1
2
3
4
5
CONTROL PANEL
6
CAR CONNECTION BOX
A
385:A1
L CED RV
XC 11:1 +24V CAR AND SHAFT
B
0/24V CAR AND SHAFT 30/CHANNEL C B30 61:U/CHANNEL A 61:N/CHANNEL B 77:U 77:N
n C o i t a r o p r o C E N O K 1 0 0 2 D ) C ( t h g i r y p o C
LCECPU
LCECCBS
1
1
2
2
3
3
1
1
4
4
2
2
5
5
3
3
6
6
4
4
7
7
5
5
8
8
6
6
7
7
8
8
SHIELD
XT2
S1
1
S2
2
9
3
10
4
11
5
12
6
SERIAL NETWORK SERIAL NETWORK +12V BATT 0/12V BATT HELP COMING ALARM INTERCOM 1 INTERCOM 2
4 A
13
7
14
8
15
9
16
10
XT1
375
972520168Gxx
XC12
E
8 06
SHIELD
16x1mm
1
S1
2
S2
3
2
+ 1x1.5mm
2x0.5mm
2
TWISTED
9
4
10
5
11
6
12
7
13
8
14
2
F
1.5 GN/Y 1.5 GN/Y G
Checked by
Language
MES
MES
EN
Approved by
Product Code
SP
RESOLVE 500
Designed by
I ss u e
Change description
H
Department Da te
D es. b y
Appr. by
Date
10/1/2006
PD
TRAVELLING CABLE I KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM
Sales ref. no.
Drawing Number
Is su e
P age
1/2
972500164E07 00
CHENNAI-600 095
CAR WIRING DIAGRAM
1
2
3
4
5
CONTROL PANEL A
CAR CONNECTION BOX 806 LCECCBS
XC1
379 LCEADOS
6
1
42:DS
7
2 8
3
51
4 5
57
9
6 B
87
7
10
8 9
11
1
XT3 1
2
2
3
3
4
4
5
5
6
6
7
XT4 1
10 11
12
2 3
8 n C o i t a r o p r o C E N O K 1 0
4
XC3 FRD FRD
1
1
2
2
6
3 230 VAC N/230 VAC
0 D 2 ) C ( t h g i r y p o C
4
3
5
4
5
9
10
7
11
XT5 1 2
972520169Gxx 2
XC4
16x1mm + 1x1.5mm 2 2x0.5mm TWISTED
1 230 VAC CAR LIGHT N/230 VAC
2
5
3
6
2
5
E
SHIELD
LWD
4 A
LWD 0/24VDC
1
WH
3
BU
2
3 4
385:A1 LCEDRV XW
12
WH
XT11 1
BU
4
SHIELD
2
13
3 5
13
6 7 8
F
9
G
1.5 GN/Y
Designed by
I ss u e
Change description
Department Da te
D es. b y
Appr. by
PD
H
Language
Checked by
MES Date
10/1/2006
MES
EN
Approved by
Product Code
SP
RESOLVE 500
TRAVELLING CABLE II KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM
Sales ref. no.
Drawing Number
Is su e
P age
2/2
972500164E07 00
CHENNAI-600 095
CAR WIRING DIAGRAM
1
2
3
4
CAR CONNECTION BOX
5
6
INSPECTION DRIVE UNIT
A
LCECCBS 806 42 :U
XB12
B
42:N
42: DS
1 1
1
2
2
3
3
3
4
4
4
2
XB3
5 1
6 6
2 3
5
4 n C o i t a r o p r o C E N O K 1 0
5
41
42:RB
7 7
XB34 1
8
2
9
0 2 D ) C ( t h g i r y p o C
E
4 A LCECCBS 806 SOCKET ON CAR ROOF
XB13
F
PE
1
BU
BN
230VAC
2
BN
BU
N/230VAC
GNYE
45 45
GNYE
G
Designed by
I ss u e
Change description
H
D es. b y
Appr. by
EN
MES
Department Da te
Language
Checked by
MES
PD
Date
Product Code
Approved by
10/1/2006
SP
RESOLVE 500
INSPECTION DRIVE KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM
Sales ref. no.
Drawing Number
Is su e
P age
CHENNAI-600 095
CAR WIRING DIAGRAM
972500164E08 00
1/1
1
2
3
4
A
6
DOOR CONTROL A-SIDE
CAR CONNECTION BOX
806 LCECCBS
5
XB7
D2 2
BK
4
BU
87
GNYE 5 728779G0*
PE
BK
1
BU
2
BN
4
2
GNYE 5
1
3
3
CAR DOOR CONTACT
GNYE GNYE
D1 728778G0*
XB16 1 BU
BU
B
X3
2 BN
XB28 1
1
4
1
2
2
3
2
2
3
5
4
3 4 n C o i t a r o p r o C E N O K 1 0
3
5
5
6
4
7
5
6
6 7
8 9
X1
1
8 9
6
10
10
8
11
0 D 2 ) C ( t h g i r y p o C
XB29 1
7
2
8
7
12 13
3 4 CURTAIN OF LIGHT (PANA 40) X15
44
45(+)
E
X1
46(-)
4 A
REFER 502280005 1(3) FOR CURTAIN OF LIGHT (PANA 40)
2
PE 0 1 B X
4
PROTECTION CIRCUIT - WIRING DIAGRAM
778949G10
F
1 5 B X
1
3 4 B X
1
2
2
G
Designed by
I ss u e
Change description
H
KONE ELEVATOR INDIA PRIVATE LIMITED 50,VANAGARAM ROAD AYANAMBAKKAM
Department Da te
D es. b y
Appr. by
Date
10/1/2006
PD
Language
Checked by
MES
MES
EN
Approved by
Product Code
SP
RESOLVE 500
DOORS AMD [drive 1] Sales ref. no.
Drawing Number
Is su e
P age
972520164E10 00
CHENNAI 600 095
1/2
CAR WIRING DIAGRAM
1
2
3
4
A
6
DOOR CONTROL A-SIDE
CAR CONNECTION BOX
806 LCECCBS
5
XB7
D2 2
BK
4
BU
KM728779GXX
PE
87
GNYE 5 BK
1
BU
2
BN
4
CAR DOOR CONTACT
GNYE GNYE
D1 KM728778GXX
XB16 1 BU
GNYE 5 BU
B
3
2 BN
XB28 1
1
4
1
2
2
3
2
2
3
5
4
3 4 n C o i t a r o p r o C E N O K 1 0
3
5
5
KM762579GXX
6
4
7
5
6
6 7
8 9
X1
1
8 9
6
10
10
8
11
0 D 2 ) C ( t h g i r y p o C
XB29 1
7
2
8
7
12 13
3 4
1
X2
2 3 4
E
5
CURTAIN OF LIGNT (PANA 40)
6
4 A
X15
2
PE 0 1 B X
4
44
X1
45(+)
KM778949G10 46(-)
REFER 502280005 1(3) FOR CURTAIN OF LIGHT (PANA 40) F
PROTECTION CIRCUIT - WIRING DIAGRAM 1 5 B X
1
3 4 B X
1
2
2
G
Designed by
I ss u e
Change description
H
Department Da te
D es. b y
Appr. by
PD
Language
Checked by
MES Date
10/1/2006
MES
EN
Approved by
Product code
SP
RESOLVE 500
DOORS KONE ELEVATOR INDIA PIRVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM
AMD [drive 2] Sales ref. no.
Drawing Number
Is su e
P age
972500164E10 00
CHENNAI-600 095
2/2
CAR WIRING DIAGRAM
1
2
3
4
5
6
CAR CONNECTION BOX LCECCBS/N A
806
+24V
XB18 1 2
EMERGENCY LIGHT
3
0/24 V
4
RS485
5
ALARM
6
RS485
7
Em. +12V
8
HELP COMING
9
INTERCOM
B
10
INTERCOM
C OB/P A-SI DE
n C o i t a r o p r o C E N O K 1 0 0 D 2 ) C ( t h g i r y p o C
X X G 5 1 8 3 1 7 M K
E
4 A
F
LCECOB/24 X S1 32 1 1-8 2
A-SIDE XS2 1
3
3
4
4
5
5 X1
6 7
G
2
A
6 B
7
8
8
9
9
10
10
Designed by
I ss ue
Change description
H
Department D at e
D es . b y
Appr. by
PD
Language
Checked by
MES Date
10/1/2006
MES
EN
Approved by
Product Code
SP
RESOLVE 500
CAR NETWORK, COP1 KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM
Sales ref. no.
Drawing Number
I s su e
P ag e
972500164E11 00
CHENNAI-600 095
1/4
CAR WIRING DIAGRAM
1
2
3
4
5
6
CAR OPERATING PANEL A
B
n C o i t a r o p r o C E N O K 1 0 0 2 D ) C ( t h g i r y p o C
8
E
B O C E C L
4 A
F
LCECOB/24 32
1
CAR CALL
A-SIDE 1
1
2
2
2
2
XC31:8
3
3
3
5
CALL 8
4
4
4
6
1
1
1
1
2
2
2
2
XC31:1
3
3
3
5
CALL 1
4
4
4
6
G
I ss u e
1
Change description
H
D es. b y
Appr. by
7
X
7
6
X
6
5
X
5
4
X
4
3
X
3
2
X
2
1
X
1
E E D R D 1 I O I 3 S O S C - L X A F B
31:8
X = SERVED FLOOR
31:1
Language
Designed by
Checked by
MES
MES
EN
Approved by
Product Code
Department Da te
8
Date
10/1/2006
PD
RESOLVE 500
SP
CAR CALLS, COP1 KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM
Sales ref. no.
Drawing Number
Is su e
P age
972500164E11 00
CHENNAI-600 095
2/4
CAR WIRING DIAGRAM
1
2
3
4
5
6
CAR OPERATING PANEL
LCECOB 32 XC7 1 44:1
A
2
EM.LIGHT
A-SIDE EMERGENCY LIGHT BN
BN
BU
BU ALARM BUTTON
XC9 1
39
2
ALARM
B
44:1
BN
BN
BU
BU
39
XC19 1
97
2
HELP IS COMING
CAR POSITION INDICATOR
XC3 1 n C o i t a r o p r o C E N O K 1 0
96 DISPLAY
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
5
5
5
5
96 7-SEG 38MM SIGMA TYPE OR DOT MATRIX SIGMA TYPE
0 2 D ) C ( t h g i r y p o C
E
4 A
F
G
I ss ue
Change description
H
Checked by
MES
MES
EN
Approved by
Product Code
SP
RESOLVE 500
Department D at e
D es . b y
Appr. by
Language
Designed by Date
10/1/2006
PD
CAR OPERATING PANEL KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD AYANAMBAKKAM
Sales ref. no.
Drawing Number
I s su e
P ag e
972500164E11 00
CHENNAI-600 095
3/4
CAR WIRING DIAGRAM
1
2
3
4
5
6
A-SIDE A
DOOR OPEN BUTTON
32
XC10 1
34
2
DOB
DOOR CLOSE BUTTON
XC11 1
34:S B
2
DCB
XC12 1
71
2
FRD
XC13 n C o i t a r o p r o C E N O K 1 0
1
37
2
OCV
XC14 1 2
0 D 2 ) C ( t h g i r y p o C
XC15 1
66
OPTION
2
OSS-C
PRIORITY CAR CALL SWITCH IN CAR
XC16 1
35
2
PRC
E
XC17 1
78
4 A
2
DOE
100
F
XC18 1 2 3
G
I ss u e
Change description
H
Designed by
Checked by
MES
MES
Department Da te
D es. b y
Appr. by
PD
Date
10/1/2006
Language
EN
Approved by
Product Code
SP
RESOLVE 500
CAR OPERATING PANEL KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD
Sales ref. no.
Drawing Number
Is su e
P age
AYANAMBAKKAM CHENNAI-600 095
972500164E11 00
4/4
CAR WIRING DIAGRAM
1
2
3
4
5
6
CAR CONNECTION BOX
LCECCBS 806 XB14
A
1 44
2
BK BU
REFER
GNYE
CAR
XB15 43
2
FAN
LIGHT
DIAGRAM:
1 B
CAR
AND
WIRING 972500107
BK BU GNYE EMERGENCY BATTERY
XB32 1 227 n C o i t a r o p r o C E N O K 1 0
2
BK
BK
KM713867GXX
RD
-
+ 227
RD
XB35 1 65
2
LWD BOX ASSY (972520182)
0 D 2 ) C ( t h g i r y p o C
DC 4 RELAY BOARD
XB50 1
1
1
FL 10
64
2
2
3
1
4
11
2 KM769678G03
OL
1
2
2
15
14
E
64
4 A
XB33 1 2
1 2
F
XB9 1 2
G
I ss ue
Change description
H
Designed by
Checked by
Language
MES
MES
EN
Department D at e
D es . b y
Appr. by
PD
Date
10/1/2006
Approved by
Product Code
SP
RESOLVE 500
CAR LIGHTING AND VENTILATION KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD
Sales ref. no.
Drawing Number
I s su e
P ag e
AYANAMBAKKAM CHENNAI-600 095
CAR WIRING DIAGRAM
972500164E12 00
1/1
1
2
3
4
5
6
CONTROL PANEL
375 DOOR ZONE INDICATION 279
A
-
3 72 72
LCE CPU
XM19 1
+
2
XM11 1
S WI WI T TC C H M OD OD UL UL E
0/24V
270:U 270:N B
4
3
1
2
2
1
3
4
270 1
2
3
4
UP
3
RECALL DRIVE
2
806
INPUT
DOWN
XC12 4
XT2 4
4
INSPECTION DRIVE 42:U
INPUT
LCECC BS
XB12
42:N
INPUT
4
CAR n C o i t a r o p r o C E N O K 1 0
DOWN
0/12V
2
1
1
2
2
RS485 RS485
1
UP
42:DS
RS485
RS485
0 2 D ) C ( t h g i r y p o C
3
INSPECTION
RS485
38 85 5 :A :A 1 L C CE ED DR RV E
*Refer Drg. No. 972520182 for details. XB50 11
10
1
XT11 1
2
4
3
3
XW 1 INPUT
4 A
3 INPUT
15
14
2 0/24V
2 4 F
LWD BOX ASSY NO. 972520182
XB31 1 +24V
3 0/24V
G
Designed by
I ss ue
Change description
H
Department D at e
D es . b y
Appr. by
PD
Language
Checked by
MES
MES Date
EN Product Code
Approved by
10/1/2006
RESOLVE 500
SP
INSPECTION DRIVE KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD
I s su e
P ag e
Sales ref. no.
AYANAMBAKKAM CHENNAI-600 095
I s su e
Drawing Number
P ag e
1/1
972500164E17 00
CIRCUIT DIAGRAM
1
2
3
4
CAR
5
6
C ONT ROL PAN EL 385:A1
A
806
LCEDRV 375
XS:1/2
LCECCBS
LCECPU
77:FU XS:1/3 GND X4
XS:1/4
X4
77:U1 XS:2/2 77:FN B
XS:2/3 GND XS:2/4
61 BAR READER 2000
n C o i t a r o p r o C E N O K 1 0
77:N1
77:U
X61/1
77:N
X61/2
XB46/1
XT1/7
XC11:1/7
X C11:2 /7
XC11 /7 77:U
XB46/2
XT1/8
XC11:1/8
X C11:2 /8
XC11 /8 77:N
0/24V X61/3
XB46/3
+15V
GND
12VDC
0 D 2 ) C ( t h g i r y p o C
Ch a
XC11/6
61:N
61:U
XB46/7
XT1/6
61:U XC11:1/6 Ch A
X61/7
XB46/6
XT1/5
XC11:1/5 Ch B
X61/5
XB46/4
XT1/3
XC11:1/3
XC11:2/3
XT1/4
XC11:1/4
XC11:2/4
Ch B
Ch c
XC11:2/6 X61/8 Ch A
Ch b
XC11 /5
+12V
XB46/5
X61/6
X C11:2 /5 61:N
XC11/3
30
Ch C
*FOR TTC CARS ONLY
E
DOOR ZONE SWITCH B30
B-SIDE
XB24/1
4 A
XB24/3
B30
XC11/4
INS. UP LIMIT SWITCH (68:U) (*OPTION)
F
XB45/1 XM19/1 XB45/2
+24V
77:S
XT1/1
XC11:1/1
XC11:2/1
XC11/1
RS485 XT1/2
XC11:1/2
XC11:2/2
XC11/2
XB27/1
G
+24V
XB27/2
*FOR SHORT FLOOR DISTANCE OR SPEED > 1.5 m/s
GND
Designed by
Change description
H
Checked by
MES
I ss ue
GND
Department D at e
D es . b y
Appr. by
PD
Date
10/1/2006
Language
MES
EN
Approved by
Product Code
SP
RESOLVE 500
CAR POSITION KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD
Sales ref. no.
AYANAMBAKKAM CHENNAI-600 095
I s su e
Drawing Number
P ag e
972500164E18 00
1/1
CIRCUIT DIAGRAM
1
2
LCEOPT/LCEGTW /REPEATER A
3
4
375 LCECPU +24V
+24V
2
0/24V
0/24V
2
5
TX+
TX+
3
TX-
4
6
TX-
3
ROLL CALL
4
GND
+ X X T T
1
6
CONTROL PANEL
XH12 1
XM13 1
RS485
5
5 6
XC12
2
8
B
CAR
n C o i t a r o p r o C E N O K 1 0 0 D 2 ) C ( t h g i r y p o C
E
SHAFT 0 1
2 1 2 T X
XS1
806 LCECCBS R O O L F P O T
+ X X T T g n i t m m m h o o o g c c c i m r r l V r V p e e V 4 4 . 2 + a - 2 l t t 2 m / X l X 1 e n n + E 0 T A T + H I I
8 1 B 1 X 2
32 LCECOB
XS1 1
XS2 1
L L V A 4 C V - + D 2 X X 4 2 N / L T T + G 0 L O R
XS2 3
4
5
6
7
8
0 9 1
+24V
2
2
Em. light
3
3
0/24V
4
4
TX+
5
5
Alarm
6
6
TX-
7
7
+12V
8
8
Help coming
9
9
Intercom
10
10 Intercom
197 LCEFCB
S R O O L F E T A I D E M R E T N I
COP 1
XS1 g t n m m h i o o m g V m V c c V i 4 + r o 4 l 2 X a X 2 c r r 2 e e 1 / T l T + t t + A . 0 p n n m l I I E e H
4 A
XS1
L L V A 4 C V - + 2 D X X 4 2 N / L T T G 0 L + O R
+24V
XS1 XS2 1 1
GND GN D
2
2
0/24V 3
3
ROLL CALL 5
5
TX -
4
4
6
6
TX+ TX +
XS2
R W 5 0 2 .
XS2
0 1
CAR CONNECTION BOX
F
XS1
R O O L F T S O M R E W O L
G
L V L 4 A V - + 4 D 2 C X X T T 2 N / + G 0 L L O R
XS2
Designed by
I ss ue
Change description
H
Checked by
MES
Department D at e
D es . b y
Appr. by
Date
10/1/2006
PD
R W 0 5 2 . 1 0
Language
MES
EN
Approved by
Product Code
SP
RESOLVE 500
SERIAL NET KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD
RS485
Sales ref. no.
AYANAMBAKKAM CHENNAI-600 095
I s su e
Drawing Number
P ag e
972500164E19 00
1/1
CIRCUIT DIAGRAM
1
2
3
CONTROL PANEL
4
5
6
CAR
A
379 LCEADOS / 230S
806 LCECCBS
XC4 E13 1/2
230VAC E13 1/2
B
XT3 5
2
XC4/2
3
K1
XB15 2
6
TO CAR FAN (Refer Drg. No. 972500107 for details.)
1
XC4/3 XB13 2
45
1
n C o i t a r o p r o C E N O K 1 0 0 D 2 ) C ( t h g i r y p o C
XB14 2 K2
TO CAR LIGHT (Refer Drg. No. 972500107 for details.)
1
XT3/6 E21 1/1 XT3/5 E21 1/1 E13 1/2
PE PE
E
4 A
F
G
Designed by
I ss u e
Change description
H
Checked by
MES
MES
Department Da te
D es. b y
Appr. by
PD
Date
Approved by
10/1/2006
SP
Language
EN Product Code
RESOLVE 500
CAR AND SHAFT LIGHT KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD
Sales ref. no.
AYANAMBAKKAM CHENNAI-600 095
Is su e
Drawing Number
P age
972500164E20 00
1/1
CIRCUIT DIAGRAM
1
2
3
CONTROL PANEL A
385:A1 LCEDRV
4
5
6
CAR 37 5 LCE CPU
CAR OPERATING PANEL
806 L CECCB S
LCECOB
32
+12VEM
XC12 3
0/12V
4
XT 2 3
X B18 7
XS1 7 XC7
B
4
1
K4 2
12VDC XH11 2 XM14:1 1
n C o i t a r o p r o C E N O K 1 0 0 D 2 ) C ( t h g i r y p o C
2 : 4 1 M X
2
3
3
4
4
2 XC19
XM14 1
2
2
1
1 8
INPUT
XC12 6
6
5
5
8
2
XC9 1 5
5 INPUT RS485
39
2
12VEM XB34 1 F2 1A
2
SHAFT XB32 2
+12V BATT ALARM BELL 139 +
1
0/12V
-
+
227
-
12VDC
XB35 2
E
1
4 A
230VAC
XT3/5 XT3/6
F
G
I ss u e
Change description
H
Checked by
MES
MES
EN
Approved by
Product Code
SP
LCE
Department Da te
D es. b y
Appr. by
Language
Designed by
PD
Date
10/1/2006
LIGHTING AND ALARM KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD
Sales ref. no.
AYANAMBAKKAM CHENNAI-600 095
Is su e
Drawing Number
P age
972500164E21 00
1/1
CIRCUIT DIAGRAM
1
2
3
4
5
6
CONTROL PANEL 375 LCECPU
A
XM13 1
+24V
2
0/24V
3
TX+
LAST BOARD
4 TXRS485 B
5
TX+
6
TX-
6
+24V
XM13A
1
0/24V 2
722:1 LCEOPT XM13A
KM729850G02
1 . .
n C o i t a r o p r o C E N O K 1 0 0 D 2 ) C ( t h g i r y p o C
TX+
3
TX-
4
TX+
5
TX-
6
6
XM13B
XM13B
1
1 . .
2 3
6
A
4 5 6
KM729850G02
722:N-1 LCEOPT XM13A 1 . . 6
E
XM13B
1 . .
4 A
6
KM729850G02
F
722:N LCEOPT XM13A 1 . . 6 XM13B
1 . .
G
TERMINATION RESISTOR
6
I ss u e
Change description
H
Designed by
Checked by
MES
MES
Department Da te
D es. b y
Appr. by
PD
Date
10/1/2006
Language
EN
Approved by
Product Code
SP
LCE
WIRING BETWEEN OPTION BOARDS KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD
Sales ref. no.
AYANAMBAKKAM CHENNAI-600 095
Is su e
Drawing Number
P age
1/1
972500164E22 00
CIRCUIT DIAGRAM
1
2
3
4
+24V 0/24V TX+ TXTX+ TX-
XM13A/1
XM13B/1
XM13A/2
XM13B/2
XM13A/3
XM13B/3
XM13A/4
XM13B/4
XM13A/5
XM13B/5
XM13A/6
XM13B/6 INPUTS: 24-110VUC 4-18mA
B
S1
6
CONTROL PANEL
722:1 LCEOPT A
5
+24V 0/24V TX+ TX-
RS485
P133/1
TX+ TX-
133 FIREMANS DRIVE
P133/2
X5/1 FRD
X5/2 FID1
1
X5/3
0 F
FID2
X5/4 EPD1
J10 n C o i t a r o p r o C E N O K 1 0 0 D 2 ) C ( t h g i r y p o C
DIR
X5/5 EPD2
INV
X5/6
J9 EPD3 FRONT
REAR
X5/7 OSS
X5/8 WSC
X5/9
X7/2
GND_IO
X7/1
+24V_IO
X6/1
+24V_IO
X5/10
X6/2 E
OUTPUTS: 12-240VUC 0.01-1A
4 A
FIREMAN'S RETURN DRIVE FRD1
X1/1
FIREMAN'S DRIVE SERVICE DOOR SWITCH MADE DC L EMERGENCY POWER DRIVE
G
EPD1
K5
X3/1
X1/2
X3/2
LIFT RUNNING START COUNTER
X1/3
X3/3
EPD2
X1/4 F
K1
K2
K6
X3/4
X1/5
X3/5
DOOR ZONE LIFT STOPPED
X1/6
X3/6
EPD3
X2/1
K3
K7
X4/1
X2/2
X4/2
OUT OF SERVICE
X2/3
X4/3
OSI-A
X2/4
K4
K8
X4/4
X2/5
X4/5
DISTURBANCE ALARM
X2/6
X4/6
DAL-GP
I ss u e
Change description
H
Designed by
Checked by
MES
MES
EN
Approved by
Product Code
SP
RESOLVE 500
Department Da te
D es. b y
Appr. by
PD
Date
10/1/2006
Language
ADDITIONAL DEVICES KONE ELEVATOR INDIA PRIVATE LIMITED 50, VANAGARAM ROAD
50, G O AYANAMBAKKAM CHENNAI-600 095
CIRCUIT DIAGRAM
Sales ref. no.
Drawing Number
Is su e
972500164E23 00
P age
1/1
A
B
D
C
E
H
G
F
0 - 0 M L I F M
3 1
E U S S I
D E V O R P P P A S
G N I H T R D E A K C S E E E
2 1
H C M
1 1
0 1
S T N E M P I U Q E M O O R E N I H C A M
E B T A S O T T L N I Y E E O R R P A A P O S E W R S T O T D M O E U M H M T I L R N L A I A E M
E D O C T C U D O R P
S E H C T I W S T I M I Y L R T T N F E A H L S L E O W T
) H C T I W S T I M I L H T I W ( c e S / M 1 > D E E P S R O F D R E O E N P R S E V R O E G V O
5
E K A R B
R O T O M N A F
3 1
2 1
1 1
A I D N I E N O K
M A R G A I D T I U C R I C
D V R P P A
N R D
E T A D
E G N A H C
E R I W I G G W S 8
0 1
9
8
E R I W . I . G G W S 2 1
R A C O T E R I W U C C V P 2 . 0 / 6 1
7
T I N U G N I D N I W
5 2 E 4 6 1 0 0 5 2 7 9
M L I F M
E U S S I
E R I W . I . G G W S 2 1
6
) M O O R E N I H C A M N I (
. O N . G W D
E T 0 A 2 D / N 2 n G N g / W i S I S 6 A R s E E R e D S D M D 1
L L A W ) N O T A H R L C E T F M I O W . T S I S . U G N C ( I A P Y M I B R T E D H S E T D H I T R V A R O E A R N E P
T E E H S
T P E D
6 0
9
8
D P
G N I H T R A E F O T U O Y A L
3 / 1
R A C O T E R I W S E U H C C T C I V W P S 2 N . I 0 A / M 6 1
T R S O I T O O H M
R E W O P
G N I T H G I L
E P Y T . N R D
E R I W I G G W S 2 1
7
E R I W . I . G G W S 8 S H N T I R A A M E M G O N R I F M O S C D A N E I L
T A L F I G M M 0 1 x 0 5
T A L F I G M M 0 1 x 0 5
S D A E L H T R A E G N I M O C N I
6
E R I W I G G W S 2 1
5
E R I W . I . G G W S 8
E P D R K
E R I W . I . G G W S 8 E R I W . I . G G W S 8
4
3
E L P E N A P E V I R D
L E N A P L O R T N 0 C
X B A K P C E A / R S A L
2
1
E R I W I G G W S 8
C V P E R 2 I . W 0 / U 6 C 1 R O T C A E R C A
E R I W . I . G G W S 8 E R I W . I . G G W S 8
N I S G N M I O K O N R U R E T N I L H A C T A E M M L L A
4
3
R E T R E V N I
2
1
A
B
C
D
E
F
G
C
D
E
F
G
H
. d t L a i d n I r o t a v e l E e n o K . d e t u c e s o r p e b l l i w n o i t n e v a r t n o C . e s o p r u p d e s i r o h t u a n u y n a r o f d e s u e b r o n y t r a p d r i h t a o t d e t r a p m i e b t o n t s u m f o e r e h t s t n e t n o c e h t d n a n o i s s i m r e p n e t t i r w r u o t u o h t i w d e i p o c e b t o n t s u m t n e m u c o d s i h T A
B
H 0 - 0 M L I F M
3 1
E U S S I
D E V O R P P S P A
G N I H T R D E A K C S E E E
2 1
H C M
E D O C T C U D O R P
1 1 K C A R T R O O D . D N A L
0 1
9
G W S 2 1 E R I W I G
8
R O K O C L O F L P E O T T A G
K C A R T R O O D . D N A L
K R C O O O L L F E d T 2 A n G
K C A R T R O O D . D N A L
) T F A H S T F I L N I (
. O N . G W D
E T 0 A 2 D / N 2 n N G g / S W I i A R s E S 6 R E e D S D M D 1
R K O C O O L L F E h T 0 t A G
N R D
E T A D
E G N A H C
0 1
9
8
I
G W S 8 E R I W I G
6
G W S 8 E R I W I G
5
2 1
1 1
M A R G A I D T I U C R I C
D V R P P A
E U S S
7
3 1
A I D N I E N O K
M L I F M
T F A H S T F I L
3 / 2
5 2 E 4 6 1 0 0 5 2 7 9
T P E D
6 0
K C A R T R O O D . D N A L
K R C O O O L L F E T t A s 1 G
D P
G N I H T R A E F O T U O Y A L
T E E H S
E P Y T . N R D
7
E R I W . I . G G W S 2 1
K N I L H T R A E U C
R O O L F H C A E T A T F A H S N I D E D I V O R P
6
5
< 4
3
2
1
4 M O O P R I R C T / S M H N T I R A D E E D M I O V R O F R P
3
2
1
A
B
C
D
E
F
G
C
D
E
F
G
H
. d t L a i d n I r o t a v e l E e n o K . d e t u c e s o r p e b l l i w n o i t n e v a r t n o C . e s o p r u p d e s i r o h t u a n u y n a r o f d e s u e b r o n y t r a p d r i h t a o t d e t r a p m i e b t o n t s u m f o e r e h t s t n e t n o c e h t d n a n o i s s i m r e p n e t t i r w r u o t u o h t i w d e i p o c e b t o n t s u m t n e m u c o d s i h T A
B
H 0 - 0 M L I F M
3 1
E U S S I
D E V O R P P P A S
G N I S E H M T R D E A K C E E
2 1
H C
E D O C T C U D O R P
1 1
D P
G N I H T R A E F O T U O Y A L
T E E H S
5 2 E 4 6 1 0 0 5 2 7 9
) R A C N I (
. O N . G W D
T P E D
6 0
E T A 0 2 D / N 2 n N G g / S W I i A R s E S 6 R E e D S D M D 1
E T A D
9
E G N A H C
8
I
7
E P Y T . N R D
6
5
1
9
7
6
2
0 1
8
E U S S
3
2 1
1 1
M A R G A I D T I U C R I C
D V R P P A
N R D
4
3 1
A I D N I E N O K
M L I F M
0 1
3 / 3
E L B A C G N I L L E V A R T
L E N A P E L O R T N O C
T C A T N O C E T A G R A C
G N I L S R A C
K C A R T R O O D R A C
H T R L A E E L N A A G N P N I I R M R R O I E O W T D
R O T O M R O O D
R A C
T H G G N I I L T T R I A F C
E
E
X O B N O I T C E N N O C R A C
5
N A F R A C
X N O A B F , N T O H I G T I C L E N R N A O C C
L E N A P G N I T A R E P O R A C D E R H E T P V R O O A C C E : & E E B T X O O O N B T
X O B R E D O C N E D C L
M R O F T A L P R A C
R A E G Y H T C E T I F A W S S
4
3
2
1
A
B
C
D
E
F
G
C
D
E
F
G
H
. d t L a i d n I r o t a v e l E e n o K . d e t u c e s o r p e b l l i w n o i t n e v a r t n o C . e s o p r u p d e s i r o h t u a n u y n a r o f d e s u e b r o n y t r a p d r i h t a o t d e t r a p m i e b t o n t s u m f o e r e h t s t n e t n o c e h t d n a n o i s s i m r e p n e t t i r w r u o t u o h t i w d e i p o c e b t o n t s u m t n e m u c o d s i h T A
B
H
- 0 0
M L I F M
3 1
E U S S I
D E V O R P P P A S
0 0 5 E V L D E S O K C E S E H E C M R
2 1
E D O C T C U D O R P
1 1
D P T P E D
S L I A T E D N O I T C E N N O C R O T S I M R E H T D N A N A F
E
N W A R D
R E N
T E E H S
T I N U G N I D N I W 2 1 R M R O F
6 0
T A 0 2 D / N 1 G / I S 0 E D 1
K K G I . . S E K D K
3 / 1
. O N . G W D
E T A D
9
E G N A H C
8
0 1
9
8 E U S S I
7
E P Y T . N R D
7
r o t i c a p a C
e t i h W / y e r G
e t i h W / y e r G
r o t s i m r e h T
e t i h W
e t i h W
) 2 1 R M ( S L I A T E D N O I T C E N
2 1 1 1 0 1 9 8
5
7 6 n w o r B
k c a l B
e u l B
4
n w o r B
k c a l B
e u l B
3
M ~
2
1 1
M A R G A I D G N I R I W
D V R P P A
N R D
6
6 2 E 4 6 2 1 1 0 0 5 2 7 9
A I D N I E N O K M L I F M
0 1
3 1
Ventilator Fan
5 e t i h W
4 e u l B
t a t s o m r e h T
3
N O C R O T O M N A F
e e n n i i N L L
2 e t i h W
e u l B
e k l a i r o B C
1
B T r e l l 1 2 0 2 3 o 2 1 0 r 0 2 9 9 0 0 t 6 6 2 2 n 2 o / C 0 Y Y L L P P P P U U S S E E K K A A R R B B
E L N O I R L T N O T C C E T R F I O D S
R R O O T T S S I I M M R R E E H H T T
D M M F H H M O O 2 3 0 4 8 2 2 N : : : O S ) I E ) N T U K W A L C O M A A R R V L B O B F E & N C & I N E E U A L U L T A S L B N I B ( O S ( I E G T R E G N I U N I D L L I G D I A D N A O V N I I W C R W O G T G N I N I C I T A N R P N A A U T C R S
6
5
4
3
2
T L U O P R T T U N O O C Y A N L A E F R
1
1
A
B
C
D
E
F
G
C
D
E
F
G
H
. d t L a i d n I r o t a v e l E e n o K . d e t u c e s o r p e b l l i w n o i t n e v a r t n o C . e s o p r u p d e s i r o h t u a n u y n a r o f d e s u e b r o n y t r a p d r i h t a o t d e t r a p m i e b t o n t s u m f o e r e h t s t n e t n o c e h t d n a n o i s s i m r e p n e t t i r w r u o t u o h t i w d e i p o c e b t o n t s u m t n e m u c o d s i h T A
B
H
- 0 0
M L I F M
3 1
E U S S I
T E E H S
E L D E . D V O P N R P . U P A S B T S F . A E H . S M T D E F K C I E H W C S
2 1
E D O C T C U D O R P
1 1
T I N U G N I D N I W 7 1 R M R O F
R O T O M D E T R O P M I 6 2 R M R O F
D P
. O N . G W D
T P E D
E
N W A R D
S L I A T E D R O T O M D N A N A F
R E N
3 / 2
T A D N G I S E D
K K G I . . S E K D K
1 1
M A R G A I D G N I R I W
D V R P P A
N R D
E T A D
9
E G N A H C
8
0 1
9
8 E U S S I
7
r o t i c a p a C
6
w o l l e Y
Yellow
2 1 1 1 0 1 9 8 7
5
d e R
k c a l B
6 n e e r G
5 4 e u l B
4
n w o r B
k c a l B
e u l B
3
~ M
Ventilator Fan
e u l B
t a t s o m r e h T
3
e e n n i i N L L
2 e t i h W
E P Y T . N R D
7
r o t s i m r e h T
e u l B
e u l B
2
6 2 E 4 6 2 1 1 0 0 5 2 7 9
A I D N I E N O K M L I F M
0 1
3 1
e u l B
e k l a i r o B C
1
B T r e l l 1 2 0 2 3 o 2 1 0 r 0 2 9 9 0 0 t 6 6 2 2 n 2 o / C 0 Y Y L L P P P P U U S S E E K K A A R R B B
E L N O I R L T N T O C C E T R F I O D S
R R O O T T S S I I M M R R E E H H T T
) R O T O M D E T R O P M I 6 2 R M / 7 1 R M ( S L I A T E D N O I T C E N N O C R O T O M N A F
D M M F H H M O O 0 2 . . 7 4 4 4 1 6 8 R M : : : ) N ) N O S K W I E C O T U A R A L L B M A B R V & O & F E E N C E U I N U L A L B L T B ( A S ( N I G O S E G N I E U N I T R L I G I A D N D L V N I D I I W A O R W C O G T G N I N I C I T A N R P N A A U T C R S
6
5
4
3
2
T L U P O R T T U N O O Y C A N L A E F R
1
1
A
B
C
D
E
F
G
C
D
E
F
G
H
. d t L a i d n I r o t a v e l E e n o K . d e t u c e s o r p e b l l i w n o i t n e v a r t n o C . e s o p r u p d e s i r o h t u a n u y n a r o f d e s u e b r o n y t r a p d r i h t a o t d e t r a p m i e b t o n t s u m f o e r e h t s t n e t n o c e h t d n a n o i s s i m r e p n e t t i r w r u o t u o h t i w d e i p o c e b t o n t s u m t n e m u c o d s i h T A
B
H
- 0 0
M L I F M
3 1
E U S S I
E L D E D V O N R P P U P A S B T F A H S T D E S F K C E I E H W C M S
2 1
1 1
E D O C T C U D O R P
T P E D
N W A R D
R E N G I S E D
D P
S L I A T E D R O T S I M R E H T D N A N A F
T E E H S
R O T O M S N E M I E S 6 2 R M R O F
3 / 3
K K . . K K
D N I E N O K M L I F M
M A R G A I D G N I R I W
D V R P P A
N R D
E T A D
9
E G N A H C
8
7
) R O T O M S N E M E I S H T I W 6 2 R M (
6
4 5
r o t i
3
c a p a C
1
2
e t i h W
4
e d u l e R B
k c a l B
n w o r B
3
M ~
1
0 1
9
8 E U S S I
2
1 1
A I
E
0 1
6 2 E 4 6 2 1 1 0 0 5 2 7 9
. O N . G W D
T A D N G I S E D
3 1
Ventilator Fan
e t i h W
) n o i t c e r t o o t r s p i m r r o e t h a T l i t n e V (
e n N i L
0 2 2 9 2 / 0 L E O N R I T L N O T C C E T R F I O D S
B T r e l l o r t n o C
S L I A T E D N O I T C E N N O C R O T O M N A F
E P Y T . N R D
7
6
5
4
3
2
1
A
B
C
D
E
F
G
C
D
E
F
G
H
. d t L a i d n I r o t a v e l E e n o K . d e t u c e s o r p e b l l i w n o i t n e v a r t n o C . e s o p r u p d e s i r o h t u a n u y n a r o f d e s u e b r o n y t r a p d r i h t a o t d e t r a p m i e b t o n t s u m f o e r e h t s t n e t n o c e h t d n a n o i s s i m r e p n e t t i r w r u o t u o h t i w d e i p o c e b t o n t s u m t n e m u c o d s i h T A
B
H 0 - 0
3 1
2 1
1 1
T I N U X B A P E N I T N E M E G N A R R A R O T C E N N O C
N O T T U B H S U P
4 2 B 4 2 A 3 2 B 3 2 A 2 2 B 2 2 A 1 2 B 1 2 A
) 1 R A C ( P O C
) T E S D N A H ( E N O H
) T E S D N A H ( E N O H P E L E T
P E L E T
1 0 G 0 0 1 0 2 5 2 7 9
9
2 0 G 0 0 1 0
8
E L B A C G N I L L E V A R T
E C L X D B E K S A C E P H E M E C
E D O C T C U D O R P
LINE
1 F 2 H 1 2
1 F H 1 2
1 1 2 F H
1 1 2 F H
6
T T I R N O U P X 4 B A P E
2 2 A
2 2 B
C A V 0 3 2
2 F H 1 2
2 F 1 2 H
2 1 2 F H
2 1 2 F H
3 2 A
C A V 0 3 2 / 0
4 2 A
3 2 B
+ T A B
4 2 B
T A B
5 V 2
V 2
1
1
+ 1 B 4
3
2
1
E P O C S R E M O T S U C
T E K C O S G U L P
L
N
T P E D
T E E H S
M A R G A I D G N I R I W X B A P E
+ 2 B
2 / 1
. O N . G W D
1 1
A I D N I E N O K
M L I F M
0 1
D V R P P A
G N I R I W E T I S
N R D
2 0 G 0 0 1 0 2 5 2 7 9
3 1
7 2 E 4 6 2 1 1 0 0 5 2 7 9
T R O P 4
E T A D
7
1 2 B
D P
E C L M A R G A I D G N I R I W E T I S
6 0 0 2 / N 3 N G W S I S E / A E S E T R A 1 E D M D M D
E G N A H C
9
8
E U S S I
2 5 2 7 9
1 2 A
E U S S I
D E V O R P P P A S
S D E T N E I A R N H F U
L IN E
0 1
) 2 R A C ( P O C
N O T T U B H S U P
S D E T N E I A R N H F U
1 0 G 0 0 1 0 2 5 2 7 9
M L I F M
* * * * * S N O I T C U R T S N I N O I T A L L A T S N I X B A P E R O F ) I E K 6 0 0 . 0 3 . 3 1 M A ( R E F E R * * * * *
E P Y T . N R D
7
6
5
4
3
2
1
A
B
C
D
E
F
G
C
D
E
F
G
H
. d t L a i d n I r o t a v e l E e n o K . d e t u c e s o r p e b l l i w n o i t n e v a r t n o C . e s o p r u p d e s i r o h t u a n u y n a r o f d e s u e b r o n y t r a p d r i h t a o t d e t r a p m i e b t o n t s u m f o e r e h t s t n e t n o c e h t d n a n o i s s i m r e p n e t t i r w r u o t u o h t i w d e i p o c e b t o n t s u m t n e m u c o d s i h T A
B
H 0 - 0
3 1
N O T T U B H S U P
2 1
1 1
) T E S D N A H ( E N O H P E L E T
) T E S D N A H ( E N O H P E L E T
) T E S D N A H ( E N O H P E L E T
) T E S D N A H ( E N O H P E L E T
) 1 R A C ( P O C
N O T T U B H S U P
L IN E
0 1
1 F 2 H 1 2
9
8
LI N E
1
1
0 G 0 0 1 0 2 5 2 7 9
0 G 0 0 1 0 2 5 2 7 9
1 F H 1 2 1 1 2 F H
) 3 R A C ( P O C
N O T T U B H S U P
S D E T N E I A R N H F U
S D E T N E I A R N H F U
LINE
1 1 2 F H E L B A C G N I L L E V A R T
N O T T U B H S U P
S D E T N E I A R N H F U
S D E T N E I A R N H F U
1 0 G 0 0 1 0 2 5 2 7 9
) 2 R A C ( P O C
1 0 G 0 0 1 0 2 5 2 7 9
LI N E
) 4 R A C ( P O C
M L I F M
E U S S I
D E V O R P P P A S
E C S L E M X D B E K A C E P H E C
E D O C T C U D O R P
D P T P E D
1 F H 1 2
1 1 2 F H
1 1 2 F H
T E E H S
M A R G A I D G N I R I W X B A P E
R E B M U N G N I W A R D
2 F 1 2 H
2 F H 1 2
2 F 1 2 H
2 1 2 F H
2 1 2 F H
2 1 2 F H
2 1 2 F H
A I D N I E N O K
M L I F M
6
1 2 2 T T 2 I R N O U P X 8 B A P E
4 2
3 2
5 2
C A V 0 3 2
C A V 0 3 2 / 0
6 2
+ T A B
T A B
5 V 2
V 2
1
1
+ 1 B 4
3
2
1
E P O C S R E M O T S U C
T E K C O S G U L P
L
N
0 1
D V R P P A
G N I R I W E T I S
N R D
E G N A H C
+ 2 B
7 2
8 2
9
8
E U S S I
7
1 1
0 2 / N G N 3 S I E W / A R S E T E R S D M A 1 D
3 1
7 2 E 4 6 2 1 1 0 0 5 2 7 9
T R O P 8
E T A D
2 F H 1 2
2 / 2
6
D
1 F 2 H 1 2
E C L M A R G A I D G N I R I W E T I S
* * * * * S N O I T C U R T S N I N O I T A L L A T S N I X B A P E R O F ) I E K 6 0 0 . 0 3 . 3 1 M A ( R E F E R * * * * *
E P Y T . N R D
7
6
5
4
3
2
1
A
B
C
D
E
F
G
H
. d t L a i d n I r o t a v e l E e n o K . d e t u c e s o r p e b l l i w n o i t n e v a r t n o C . e s o p r u p d e s i r o h t u a n u y n a r o f d e s u e b r o n y t r a p d r i h t a o t d e t r a p m i e b t o n t s u m f o e r e h t s t n e t n o c e h t d n a n o i s s i m r e p n e t t i r w r u o t u o h t i w d e i p o c e b t o n t s u m t n e m u c o d s i h T
1
2
3
4
5
6
A
PARAMETERS TO BE ENTERED IN V3F10CL
B
n C o i t a r o p r o C E N O K 1 0 0 D 2 ) C ( t h g i r y p o C
E
4 A
PARAMETER --A1-02 D1-01 D1-02 D1-03 D1-05 D1-06 E1-01
DESCRIPTION MOTOR KW SPEED Control Method Relevelling Speed Levelling Speed Nominal Speed Intermediate Speed Ins./Corr. Speed Input Voltage
MR17 13.5 1.5 FluxVector 2 2 50 30 11.11 415
MR17 13.5 1.8 FluxVector 2 2 50 30 13.33 415
MR26 20 1.5 FluxVector 2 2 50 30 11.11 415
MR26 20 1.8 FluxVector 2 2 50 30 13.33 415
E1-04 E1-05 E1-06 E1-09 E2-01 E2-02 E2-03 E2-04 E2-05 F1-01
Max Frequency Motor Voltage Base Frequency If Open Loop Motor Current Motor Slip MotorNo-Load Curr. Number of Poles Motor Ph to Ph Res Encoder Pulses
50 360 50 1.5 30 3.33 18 4 0.8 1024
50 360 50 1.5 30 3.33 18 4 0.8 1024
50 310 50 1.5 53 2.52 24.8 4 0.267 1024
50 310 50 1.5 53 2.52 24.8 4 0.267 1024
F
G
Designed by
I ss ue
Change description
H
Checked by
MES Department Da te
Des . b y
Appr. by
PD
MES Date
Approved by
10/1/2006
SP
V3F10CL PARAMETERS KONE ELEVATOR INDIA PRIVATE LIMITED
Language
EN Product Code
RESOLVE 500
50, VANAGARAM ROAD AYANAMBAKKAM CHENNAI-600 095
Sales ref. no.
Is su e
Drawing Number
P ag e
1/1
972500164E28 00
V3F10CL PARAMETERS A
B
D
C
E
H
G
F
M L I F M
3 1
E U S S I
0 0
D E V O R P P P A S
1 0 G 0 1 1 0 2 5 2 7 9
2 1
1 1
D C L R A C
E C L
C A
1 R E S
E D O C T C U D O R P
3 C X
C A
B O C E C L
+ A B
T P D E D P
T E E H S
4 / 1
R E B M U N G N I W A R D
D K H C N R D
9
E T A D
7 1 9 3 6 2 M K
9 2 E 4 6 2 1 1 0 0 5 2 7 9
1 1
D N I E N O K M L I F M D V R P P A
R A C
3 1
A I
6
E 0 T A 0 D 2 R E / N N G 3 G N I I S W / S A R S E E 9 E R D D S D M
P O C
0 1
D E K C S E E H C M
M A R G A I D G N I R I W E T I S
M A R G A I D G N I R I W D W L + D C L + S A L
E G N A H C
M A R G A I D T I U C R I C
0 1
9
8
8 E P Y E T U . S N S I R D
7
+ A B 1 R E S
R E D O C N E
7
6
6
1 0 G 1 8 3 3 1 7 M K
5
4
D R A O B T P O E C L
A 3 1 M X
B 3 1 M X
3 1 0 G 4 0 2 0 2 5 2 7 9
P O T R A C N I X O B D C L
T U P T U O V 4 2
2
B O C E C L 1
2 S X
P O C
T I N U S A L
1 D W L
D R A O B T P O E C L
B 3 1 M X
5
A 3 1 M X
2 D W L
X O B R E I F I L P M A D W L
1 0 G 5 4 6 8 8 R E I F I L P M A
D E T A N I M R E T E B R D O L T U S O I H S S E R T I N N O U I T S A A N L I M
1 0 G 2 0 2 0 2 5 2 7 9
1 2 / / 4 X 4 X
: E T O N
N R I E T B 3 H 1 T M I X W
4
3
2
1
A
B
C
D
E
F
G
C
D
E
F
G
H
. d t L a i d n I r o t a v e l E e n o K . d e t u c e s o r p e b l l i w n o i t n e v a r t n o C . e s o p r u p d e s i r o h t u a n u y n a r o f d e s u e b r o n y t r a p d r i h t a o t d e t r a p m i e b t o n t s u m f o e r e h t s t n e t n o c e h t d n a n o i s s i m r e p n e t t i r w r u o t u o h t i w d e i p o c e b t o n t s u m t n e m u c o d s i h T A
B
H
M L I F M
3 1
E U S S I
0 0
D E V O R P P P A S
1 0 G 0 1 1 0 2 5 2 7 9
2 1
1 1
D C L R A C
E C L
C A
1 R E S
E D O C T C U D O R P
3 C X
C A
B O C E C L
+ A B
T P D E D P
T E E H S
4 / 2
D N I E N O K
D K H C N R D
9
E T A D
7 1 9 3 6 2 M K
1 1
A I
M L I F M D V R P P A
R A C
3 1
9 2 E 4 6 2 1 1 0 0 5 2 7 9
R E B M U N G N I W A R D
6
E 0 T A 0 D 2 R E / N N G 3 G N I S I W / A R S E S E 9 E R D S D M D
P O C
0 1
D E K C S E E H C M
M A R G A I D G N I R I W E T I S
M A R G A I D G N I R I W D C L + S A L
E G N A H C
M A R G A I D T I U C R I C
0 1
9
8
8 E P Y E T U . S N S I R D
7
+ A B 1 R E S
R E D O C N E
7
6
6
1 0 G 1 8 3 3 1 7 M K
5
4
D R A O B T P O E C L
A 3 1 M X
B 3 1 M X
3 1 0 G 4 0 2 0 2 5 2 7 9
P O T R A C N I X O B D C L
2
B O C E C L 1
2 S X
T I N U S A L
D R A O B T P O E C L
B 3 1 M X
5
A 3 1 M X
R O T S I S E R N O I T A N I M R E T
P O C
: E T O N
D E T A N I M R E T E B R D O L T U S O I H S S E R T I N N O U I T S A A N L I M N R I E T B 3 H 1 T M I X W
4
3
2
1
A
B
C
D
E
F
G
C
D
E
F
G
H
. d t L a i d n I r o t a v e l E e n o K . d e t u c e s o r p e b l l i w n o i t n e v a r t n o C . e s o p r u p d e s i r o h t u a n u y n a r o f d e s u e b r o n y t r a p d r i h t a o t d e t r a p m i e b t o n t s u m f o e r e h t s t n e t n o c e h t d n a n o i s s i m r e p n e t t i r w r u o t u o h t i w d e i p o c e b t o n t s u m t n e m u c o d s i h T A
B
H
M L I F M
3 1
E U S S I
0 0
D E V O R P P P A S
2 1 D E K C S
E E E H C C M L E D O C T C U D O R P
1 1
M A R G A I D G N I R I W E T I S
M A R G A I D G N I R I W D W L + S A L
T E E H S
D N I E N O K
D K H C N R D
E T A D
9
E G N A H C
T S I S E R N O I T A N I M R E T
7
6
9
T I N U S A L
D R A O B T P O E C L
A 3 1 M X
7
B 3 1 M X
6
1 0 G 2 0 2 0 2 5 2 7 9
1 0 G 4 0 2 0 2 5 2 7 9
1 D T W U L T P U O V 4 2
4
B O C E C L
2 S X
P O C
D E T
2 D W L
X O B R E I F I L P M A D W L
1 0 G 5 4 6 8 8 R E I F I L P M A
1 2 / / 4 4 X X
2
: E T O N
1
0 1
E P Y E T U . S N S I R D
R O
3
M A R G A I D T I U C R I C
8
8
5
1
A I
M L I F M D V R P P A
0 1
3 1
9 2 E 4 6 2 1 1 0 0 5 2 7 9 1
R E B M U N G N I W A R D
T P D E D P
6 E 0 T 0 A D 2 R E / N N G 3 G N I I S W / S A R S E E 9 E R M D D S D
4 / 3
A N I M R E T E B R D O L T U S O I H S S E R T I N N O U I T S A A N L I M N R I E T B 3 H 1 T M I X W
5
4
3
2
1
A
B
C
D
E
F
G
C
D
E
F
G
H
. d t L a i d n I r o t a v e l E e n o K . d e t u c e s o r p e b l l i w n o i t n e v a r t n o C . e s o p r u p d e s i r o h t u a n u y n a r o f d e s u e b r o n y t r a p d r i h t a o t d e t r a p m i e b t o n t s u m f o e r e h t s t n e t n o c e h t d n a n o i s s i m r e p n e t t i r w r u o t u o h t i w d e i p o c e b t o n t s u m t n e m u c o d s i h T A
B
H
M L I F M
3 1
E U S S I
0 0 M
D E V O R P P P A S
1 0 G 0 1 1 0 2 5 2 7 9
2 1
1 1
D C L R A C
D E K C S
E E E H C C M L
C A
1 R E S
E D O C T C U D O R P
3 C X
C A
B O C E C L
+ A B
T P D E D P
E T
6 0 0
A D 2 R E / N N G 3 G N I I S W / S A R S E E 9 E R D D S D M
P O C
0 1
A R G A I D G N I R I W E T I S
M A R G A I D G N I R I W D W L + D C L
D N I E N O K
N R D
E T A D
7 1 9 3 6 2 M K
1 1
A I
D K H C
9
9 2 E 4 6 2 1 1 0 0 5 2 7 9
. O N . G W D
M L I F M D V R P P A
R A C
4 / 4 3 1
T E E H S
E G N A H C
M A R G A I D T I U C R I C
0 1
9
8
8 E P Y E T U . S N S I R D
7
+ A B 1 R E S
R E D O C N E
7
6
6
R O T S I S E R N O I T
5
A N I M R E T
4
D R A O B T P O E C L
A 3 1 M X
B 3 1 M X
3 1 0 G 4 0 2 0 2 5 2 7 9
5
P O T R A C N I X O B D C L
T U P T U O V 4 2
2
B O C E C L 1
2 S X
P O C
D E T A N I M R E T E B R D O L T U S O I H S S E R T I N N O U I T D A C N L I M N R
1 0 G 2 0 2 0 2 5 2 7 9
1 D W L
2 D W L
X O B R E I F I L P M A D W L
1 0 G 5 4 6 8 8 R E I F I L P M A
1 2 / / 4 X 4 X
: E T O N
I E T B 3 H 1 T M I X W
4
3
2
1
A
B
. d t L a i d n I r o t a v e l E e n o K . d e t u c e s o r p e b l l i w n o i t n e v a r t n o C . e s o p r u p d e s i r o h t u a n u y n a r o f d e s u e b r o n y t r a p d r i h t a o t d e t r a p m i e b t o n t s u m f o e r e h t s t n e t n o c e h t d n a n o i s s i m r e p n e t t i r w r u o t u o h t i w d e i p o c e b t o n t s u m t n e m u c o d s i h T
C
D
E
F
G
H
1 . . d e t d s L e o t p r r a i n a u d e p p t m n I t i d i e r e s r w b i o t r r t o a u o h v o n t e l u E t t a u s n o u u e h m n t y o K i f n w o a e . d d r r e e o e t i h f p t u o d c c s e e t s s e n u o b e r t e p t n b o o e b n c r o l t e n l s h i u t y m t w d r t n a n n a p o i e t m n d u o r n c i i e o s h v d s t a i r t s m a i r n h e o o C T p t
2
3
4 D /1
KRD panel
5
1
2
1
2
1
2
W
(0B)
-
2 7
2 6
1 A
1 7
1 1 6 5
2 5
3
5
1
U/2
4
4
3
V/2
6
6
5
U2
W2
W2
V2 U2
1 1 V
46
~
5
N
N1
6
X3/3
a
1
83
84 3 KM1 1
2 1 V
2
1
83
Brake 2
84
202
0
C2 (+24V) XP4
46
A11
SC/11
(0/24) XP13
b
201
V
2
239:F
L E N A P BK+ E V I R BK- D 0 0 5 E V L O S E R
D1 ~
POW P1
W/2
Winding unit
1
XP9
XP8-1
C.T
P
Hoist motor
KM
XP8-2
T2
X1/1
13
A
2
0
CPU
X3/2
X1/2
0
2
C1
X1/3
28
1
TR1
A : 2
X1/4
0
12
K M1
13 connections (refer page 2/2)
X3/1 28
11
(24V)
X2/1
0
10
V2
V
F2
X2/2
C
U
+
CBT
28
KM
IM
D21 TR2
9
HS
F4
(48V)
B
8
D/ 2 F3
A
) sB4 e i r e tB3 t a b VB2 2 1 X B1 4 (
7
6
82
XP12
C
286/2
81 SC/12
X3/4
LC2
Choke
D
B
D SC/13 286/4
I/O SC/2
XP5
F1
1
P1 1
CAR
(+24V) XP2
2 N1
A11 33
34
RS
CPU
IN/4
2
IK
RPA
13
MAGNETIC SWITCH
14
3
~
24 14
A12:A
13
KM 53
A2
53
SAFETY CIRCUIT BEGIN
14
SC/42
23
24
A11 A2
11
14
A1
A1
61
A2
62 SC/43
L1 1
SAFETY CIRCUIT RETURN
KM D8
A1
81
D2
54
373
F5
2
0B
KM 1
54
82
M
:K
1
E L E XM1/1 N A LCEADOS P XM1/3 L O R T N O C F SC/42 0 0 5 E V L SC/43 O S E R G
SC/20
SC/30
5
1
A1
G
FUSE 1A
KM
RM
FR2
A11 13
DOR:F
T2 2
21
DOR:1
FR1 13
14
A1:1
4
M
From corresponding terminals in lift controller
373 A12:A
3
4 P X
OA
F
CK
A2
E30
NOTE: VERSION G02 - 10KW 60% the time is 5 seconds. Time limit to activate Nudging function.
13 Nudging in use
0
0
4
0=OFF, 1=ON, 2=NUD L, 3=NUD AU, 4=NUD NA
14 Nudging limit
20
10
59
10 .. 59 seconds, 1 second steps
0
0
99
0.0=not in use, 0.1 .. 9.9 seconds, 0.1second steps
When doors are opening or opened, the hold open time can be reduced by entering a new car call including the floor where the elevator is standing. E.g.. 1.0=reducing time to 1.0 seconds.
20
0
99
0. 0 . . 9. 9 se co co nd nds , 0. 1s 1s ec ec on ond st st ep eps
Guaranteed remaining door hold open time after Photocell / Curtain Of Light break.
Door
15
Quick close with new car call
16 Photocell delay
LCE USER INTERFACE MENU 813131
Quick close by photocell Simultaneous Simultaneou s door 18 opening forbidden 17
20 Door buzzer
21 1
Elevator parameters
Extended door reopen time
Compatible with LCE sw database 6.7.18 7.0.12
2
1
0
1
0=OFF, 1=ON
Photocell / Curtain Of Light is allowed to shorten the door hold open time to Photocell delay (menu 1-16) value.
3
1
3
1=A-door first, 2=B-door first, 3=simultaneous opening
TTC CTF function. Should be used only with locking of calls.
0
0
3
0=OFF, 1= 1=ON, 2=CGM I,3=DOI
GOH IT function for handicapped people. When the door reaches open limit the COP buzzer sounds informing free pass for blind people.
0
0
3
0=Button (DOE B), 1=Switch and buzzer (DOE SI), 2=Switch without buzzer (DOE S) 3=DOE T(DOE toggle for marine use)
DOE=Door reOpen with Extended time. LCECOB board (pos. 32) input XC17 (34:E).
22 DOP type
Values to be Set 0
23 Door type
Function
LCE UI Version 6.70
Min
Max Values
0
1
1
0
16
24 Door type B
0
0
16
25 Door opening time
20
0
26 Door closing time
20
0
Description
0=none, 1=DOP CS 0=none, 1=ADV(AMD), 2=continuous torque, 3=timer control, 4=swing + AMD, 5=swing+continuous torque, 6=swing+timer control, 7=swing, 8=swing+car Besam, 9=swing+automatic car Besam, 10=swing+landing Besam, 11=swing+automatic landing Besam, 12 = MAC, 13=GAL, 14=Freight doors (Peelle or Courion), 15=swing+MAC, 16=swing+GAL 0=none, 1=ADV(AMD), 2=continuous torque, 3=timer control, 4=swing + AMD, 5=swing+continuous torque, 6=swing+timer control, 7=swing, 8=swing+car Besam, 9=swing+automatic car Besam, 10=swing+landing Besam, 11=swing+automatic landing Besam, 12 = MAC, 13=GAL, 14=Freight doors (Peelle or Courion), 15=swing+MAC, 16=swing+GAL
Select DOP type.
99
0-9.9 s se econds, 0. 0.1 s se econd st steps
Door o op pening titime at at fu full sp speed wh when do door tty ype is is ttiimer c co ontrol.
99
0-9.9 s se econds, 0. 0.1 s se econd st steps
Door c cllosing titime at at fu full sp speed when do door tty ype is is ttiimer c co ontrol.
Select front door type
Select rear door type
0=retiring ramp released at 30 + 61:U OR 61:N + ramp energized
Retiring ramp control
0
0
5
30 Parking floor
0
0
**
29
If group parking is selected (menu 1-33) then this parameter value for Lift 1 is primary parking floor (PAM) and this value for Lift 2 is secondary parking floor (PAS) of group control. This should be zero for Lift 3 and also for Lift 2 if PAS is not wanted.
0
0
3
30
1
99
0=off, 1=A-door first, 2=B-door first, 3=both doors open 1 .... 99 99 s se econds, 1 second st steps
33 Parking mode
0
0
2
0= of of f,f, 1= 1= si si n ng gl e el e ev v at at or or , 2= gr gr o ou up p pa a rk rk in ing
0
0
**
0=not in use, otherwise floor number from lowest floor to highest floor
ADF=automatic dispatch from specif ADF=automatic specified ied floor. Va Vacant cant elevato elevatorr will be sent away from this floor.
0
0
**
0=dispatch to main floor, otherwise floor number from lowest floor to highest floor
ADF will send elevator to this floor
36 ARH function
15
0
254
0=no ARH, any other value = ARH time in minutes.
Automatically returns hy hydraulic draulic drive after the tim time e in minute minutes. s.
37 Park area used
0
0
1
0=OFF, 1=ON
Enables or disables Park Area (PAR) feature. Also select group parking (menu 1-33=2).
38 Park low limit floor
0
0
**
39 Park high limit floor
0
0
**
40 Car calls backward 41 False car call canceling
1 1
0 1
1 2
1
0
1
Automatic 34 dispatching from a specified floor Automatic 35 dispatching return floor
42
Calls
0 or floor number from lowest floor to highest floor
Door open during parking 32 Parking delay 31
Parking
when shaft contact closed 1=retiring ramp released at 30 and 61:U AND 61:N + ramp 0= Ramp with two vanes + Shaft door contact energized when shaft contact closed 1= Ramp with three vanes + Shaft door contact 2=retiring ramp released at 30 + 61:U OR 61:N + ramp energized when car and shaft contacts are closed 2= Ramp with two vanes + Car door contact 3= Ramp with three vanes + Car door contact 3=retiring ramp released at 30 + 61:U AND 61:N + ramp energized when car and shaft contacts are closed 4= Ramp with two vanes + Car door open 4=retiring ramp released at 30 + 61:U OR 61:N + car door open + 5= Ramp with three vanes + Car door open ramp energized when car door starts closing 5=retiring ramp released at 30 + 61:U AND 61:N + car door open + ramp energized when car door starts closing
Car call registered buzzer
Landing call 43 bypassing allowed
1
0
2
44 Attendant service service
2
0
5
0=not in use, otherwise lowest floor of the park area 0=not in use, otherwise highest floor of the park area 0=OFF, 1=ON Su Sub bme nu nu 1: [ 0, 0, 1, 1, 2, 2, 3, 3, 4] 4] 0= 0= OF OFF, 1 =F =FC C C , 2=FCC L, 3=FCC B, 4=FCC D Submenu 2: [0,1]0=OFF, 1=FCC R
0=OFF, 1=ON
Door function during parking. Time th that el elevator ha has tto o be be va vacant be before iitt ca can be be pa parked. 1=PAD option for this elevator, this elevator parks always to 'Parking Floor' (menu 1-30). 2=this elevator participates to group parking (PAM and PAS) and 'Parking Floor' parameter is used by group.
Select the lowest floor of the park area. Valid only if menu 1-37=1. Select the highest floor of the park area. Valid only if menu 137=1. Elevator can accept car calls also behind travelling direction. FCC C = Car calls canceled after the car made a number of stops without interrupting the beam of the safety ray or curtain of light or without opening swing door, FCC L = Cancelling of car calls is based on measuring the load of the cars (less or equal 5%) and comparing it against the number of car calls entered, FCC B = Cancelling of car calls is based on the load or passengers cutting the safety ray, FCC D = Cancelling of false destination calls, FCC R = Cancellation of active car call . Buzzer in COP will give short sound when car call is registered.
0=OFF, Elevator can in certain conditions bypass a young landing call 1=use Timed Out Call 2=use Timed Out Call ( no priority for FET/FEB when serving old landing call. Improves traffic handling capacity. calls) 0=No ATS, 1=normal ATS, 2=ATS HK, 4=ATS Determines how attendant service station in COP is working. C, 5=ATS NA
LCE USER INTERFACE MENU 813131
45 Locking type
High priority call 46 down [ 1 .. 3 ]
High priority call up 47 [ 1 .. 3 ]
1
Elevator parameters
Compatible with LCE sw database 6.7.18 7.0.12
0
0
0
0
0
0
3
**
**
LCE UI Version 6.70
0=no locking, 1=car calls locked (LOC E), 2=landing calls locked (LOL E), 3=car and landing calls locked Submenu 1: First selected floor for priority normal down call Submenu 2: Second selected floor for priority normal down call Submenu 3: Third selected floor for priority normal down call Submenu 1: First selected floor for priority normal up call Submenu 2: Second selected floor for priority normal up call Submenu 3: Third selected floor for priority normal up call
3
Defines use of Locking Inputs on LCEOPT card.
PRA = Priority At Landing option. Defines max three floors for high priority normal down calls. 0=no floor, otherwise floor number for high priority call down
PRA = Priority At Landing option. Defines max three floors for high priority normal up calls. 0=no floor, otherwise floor number for high priority call up
De-fault EU
Min
48 Call cancelling point
1
0
2
0= Calls cancelled at stopping 1= Calls cancelled at deceleration deceleration point 2= Car calls cancelled at deceleration point
Defines cancelling calls. With automatic doors calls are cancelled at deceleration point. With swing doors or automatic+swing doors calls are cancelled at stopping.
49 Delayed Fault Timer
5
0
59
seconds
Time to transfer hall call to another elevator after failing
1
1
8
Elevator number
Must be 1 or 2 in Duplex elevators, and 1, 2 or 3 in Triplex.
33
21
64
0
0
8
2
0
3
Elevator number in E-link and PC group communication 0=KoneXion not activated 1 .. 8=Elevator number 0=no reopening, 1=one opening, 2=several openings, 3=REO HK
Each elevator connected to E-link (33-64) or PC group (21-30) must have different node number. Each elevator connected to one KoneXion Base Unit must have different KoneXion elevator number. Selects how many time a landing call can reopen the door of the elevator which has car calls.
Function
Elevator number in 50 group Elevator number in 51 E-link or PC group Elevator number in 52 KoneXion 53 Reopen type
Max Values
Group Floor number. 54 Lowest floor
1
1
**
Shaft setup must be done after changing lowest floor !
Description
FEB * option. Should be used only in elevator groups where one or more elevators reach a lower floor than the bottom floor of the group. Elevator must be at bottom floor and in RDF when this is changed. Those of menu 1 submenus 30, 34, 35, 59, 64 and 89 that have non-zero value lower than new lowest floor will
be changed to be the same as the new lowest floor !
55 Group ID for E-link
0
0
32
Group nu number = 0, 2, 2, 4, 4, 6, 6, et etc..
56 Group size
1
1
8
58 Group Type
0
0
1
59 Fire reserve floor
0
0
**
Group size 0 = Embedded group interface 1 = PC group interface 0 or floor number from lowest floor to highest floor
60 Recall floor
61 Area code
1
8
**
0
**
Floor number
26
0=not in use, 1=DE, 2=CS, 3=BE, 5=FR, 6=UK N, 7=NL, 8=UK S, 10=SE, 11=HK, 12=AU, 13=AE, 14=MY, 15=SG, 16=IN, 17=AP, 18=SA, 19=TW, 20=NZ, 21=L NZ, 22=CA, 23=US, 24=EN81-72, 25=EN81-72 Car sw, 26=KR 0=none, 1=FRD, 2=FID BCI, 3=FID BOI, 4=FID BCI + FRD, 5=FID BOI + FRD, 6=FID MCI, 7=FID MOI, 8=FID MCI + FRD, 9=FID MOI + FRD,10=FID ACI,11=FID AOI, 12=FID ACI + FRD,13=FID AOI + FRD
Fire
62 Type
1
0
13
63
Door opening side during fire detection
1
1
4
64
Emergency drive destination floor
0
0
**
65
Door position after emergency drive
0
0
3
66 Fire protection door
0
0
2
67 Lifts to lobby
1
0
8
68 Lifts to second lobby
0
0
8
0 De-fault EU
0
**
Emergency
Peak
69 Second Main floor 1
Elevator parameters
Function 70
Full load indication percentage
80
Min 50
Defines group control type Fire reserve floor. Must be zero with FID B and FID M. Fire Detection (FID) and Fireman's Drive (FRD) phase one return floor. Note: EN81-72 uses parameter 7.55 to define FRD return floor. 1=Germany, 2=Russia, 3=Belgium, 5=France, 6=United Kingdom normal, 7=Holland, 8=United Kingdom firefighting, 10=Sweden, 11=Hong Kong, 12=Australia, 13=United Arab Emirates, 14=Malaysia,, 15=Singapor 14=Malaysia 15=Singapore, e, 16=Indone 16=Indonesia, sia, 17=Asian Pacific, 18=Saudi Arabia, 19=Taiwan, 20=New Zealand, 21=New Zealand lockout, 22 = Canada, 23 = USA, 24=EN81-72, 25=EN81-72 with in car switch, 26 = Korea
Defines if there is FID, FRD or FID + FRD.
Defines how doors of main return floor and alternative return floor will stay after FID or FRD phase one return drive. Note: EN81-72 uses parameter 7.56 to define FRD return side. EPD = Emergency Power Drive option. Defines EPD function 0=next possible floor, otherwise floor number return floor. EPD can be activated LCEOPT board pos 722:1 input from lowest floor to highest floor X5/4. If MARINE Settings is valid this parameter is SSM return floor for marine area. 0=doors closed, 1=A-door open, Defines how door will stay after Emergency Power Drive return 2=B-door open, 3=both doors open drive. FPD *O = Fire Protection Door, All floors / Specified floors, One landing is disconnected. FPD *S = Fire Protection Door, All floors 0=no FPD, / Specified floors, also landing below and above are 1=FPD *O, disconnected. Fire Protection Door inputs (normally closed) on 2=FPD *T LCEOPT board pos. 722:8 - 722:B must be activated by this parameter. Number of lifts to return to the main floor during Defines the number of lifts to return to the main floor during Up Up Peak Peak. Main floor is selected by menu 1-1 value Defines the number of lifts to return to the second main floor Number of lifts to return to the second main during Up Peak. Second main floor is selected by menu 1-69 floor during Up Peak value Floor number Select the second main entrance floor 1=A-door+A-door, 2=B-door+A-door 3=A-door+B-door, 4=B-door+B-door
Max Values 99
Selects group number for E-link. All elevator groups groups conn connected ected to EE-link link system ((even even in diffe different rent workstations) must have unique Group ID number. Use even numbers 0, 2, 4, 6, … only. Group size the lift is member in
Description Full load % limit can be adjusted here. Does not effect to the overload limit (110%) and LWD potentiometer adjustments. Elevator bypasses landing calls when full load is on.
% of capacity
LCE USER INTERFACE MENU 813131
71
Inspection drive
Compatible with LCE sw database 6.7.18 7.0.12
3
0
5
limited
0
0
**
73 Out of service door
0
0
3
0
0
15
74
Priority landing call type
0=SED B, stop at 77:N(+77:S) and 77:U(+77:S), 1=SED T, stop at 77:U(+77:S), 2=SED P, stop at 77:N(+77:S), 3=SED W, stop at terminal floor (at least one 61 vane), 4=SED W + OTB AU A-side, 5=SED W + OTB AU B-side.
Out of service recall floor
72
LCE UI Version 6.70
Switch in car: 0=nearest floor, 1… dedicated return floor Switch at landing: 0=switch location floo floor, r, 1… dedicated return floor 0=doors closed, 1=A-door open, 2=B-door open, 3=both doors open 0=no PRL, 1=PRL LA, 2=PRL LO, 3=PRL HA, 4=PRL HO, 5=HEL AI, 6=HEL OI, 7 = HEL CI, 8=HEL CI + PRL LA, 9=HEL CI + PRL LO, 10=PRL HA + PRL LA,
4
Inspection drive (car roof buttons) operation area can be limited by deceleration switches (pos. 77:U and 77:N). Inspection drive stops latest at the terminal floor level.
OSS=Out Of Service. If this parameter is zero then COP OSS key switch stops the elevator to nearest floor and landing OSS key switch returns elevator to the key switch location floor. Otherwise elevator returns to this floor by all OSS inputs. If MARINE Settings is valid this parameter is WSC M return floor for marine area. Door state after OSS recall function.
Defines the way how this elevator is serving Priority Landing calls (connected to LCEFOB).
11=PRL HA + PRL LO, 12=PRL HO + PRL LA, 13=PRL HO + PRL LO 14=HEL CI + PRL LA (with HEL override of PRC), 15=HEL CI + PRL LO,(with HEL override of PRC) 75 Car fan saving
5
0
59
0 .. 59 minutes before shutting off, 1 minute increments. 0 .. 59 minutes before shutting off, 1 minute
Delay timer for car fan. Shuts off the fan after the car has been vacant and time is elapsed. See also parameter 1-92 Fan type. Delay timer for car light. Shuts off the car light after the car has
76 Car light saving
Misc.
77
Car light voltage supervision
KoneXion car light current detector Car light in OSS 79 mode 78
Compulsory 80 stopping at main floor
81 Floor passing signal
83
1
Flashing overload indicator
5
0
59
1
0
0 1
0
increments.
been vacant and time is elapsed. See also parameter 1-98 Light Type
2
0=no CLS 1=CLS O (door parked open with CLS fault) 2=CLS C (door parked closed with CLS fault)
CLS option. Elevator will be stopped if car light voltage is missing on car roof board (LCECCB).
0
1
0=OFF, 1=ON
Car light current detector is connected to KoneXion car unit.
0
1
0=OFF, 1=ON
Car light can be switched OFF in OSS mode. OSS car key switch can be used to close the elevator and shut the light.
6
0=no stopping 1=down direction with normal operation 2=up direction with normal operation 3=both directions with normal operation 4=down direction with security door operation 5=up direction with security door operation 6=both directions with security door operation
CSM option. When driving past the main floor the elevator makes a normal stop to let a security guard to check the people inside the car. If TTC car then both doors are opened.
0
0
0
2
0=OFF, 1=HAN C, 2=HAN B
HAN C and HAN B options. An audible floor passing buzzer signal in COP telling to the passengers that the car is either stopping or passing the floor. HAN C is active all the time. HAN B is activated for one travel at a time with KSS button in car.
0
0
1
0=OFF, 1=ON
Overload indication in COP can be selected to be blinking.
1=Normal PRC (PRC K) 2=PRC with impulse and timer (PRC B) 3=Community of indep. states (PRC CS) 4=FSC AU and PRC K 5=PRC T flash card with 3min timeout 33 = Canada, 34 = USA, 50 = New Zealand
Priority Call in Car option. Activated by LCECOB board (pos. 32) input XC16 (35).
84 Priority car call type
1
1
50
85 Start Delay
0
0
254 254
86 EAQ in use
0
0
1
87 EBD in use
0
0
2
88 FRE door
0
0
3
89 FRE floor
0
0
**
90 Dual duplex control
0
0
3
91 DOM in use
0
0
3
De-fault EU
Min
Elevator parameters
Function
Power up loading of building power supply can be reduced. Elevator is starting after air conditioning devices etc. EAQ = Earthquake option. EAQ inputs on LCEOPT board pos. 0=EAQ not in use, 1= 1=EAQ in use 722:1 must be activated by this parameter. EBD = Emergency Battery Drive. EBD function must be activated 0= EB EBD n no ot in in us use , 1= EB EBD iin n us use , 2= UPS UPS in us use by this parameter. Not used in NA. Use parameter 7-51. FRE = Fast Recall. Defines which door will be opened after FRE 0= no no t i n us e, e, 1= 1= AA- d do oo r, r, 2= 2= BB- d do oo r, r, 3= 3= bo bot h switch is returned to the 'OFF' position. 0=PU 0=PUD D not not in use, use, dela delay y ttim ime e in in sec secon onds ds
0=not in use, otherwise floor number from lowest floor to highest floor
When FRE is activated by its LCEOPT board input, the elevator returns non-stop to the FRE return floor without opening its doors.
0=not in use Parameters are set to accept FET/FEB calls for two of the 1=serve all calls elevators and normal up/down calls are denied in main floor for 2=do not serve normal calls on main floor the third elevator. 3=do not serve FET/FEB calls on main floor 0=DOM not in use, 1=DOM in use, 2=EBULI in DOM = Door Open Monitoring option on or off. Ebuli configuration. use, 3=Automatic door EBULI
Max Values
Description
LCE USER INTERFACE MENU 813131
92 FAN type
Compatible with LCE sw database 6.7.18 7.0.12
0
0
5
LCE UI Version 6.70
0 = OCV A-Automatic, no switch 1 = OCV AF-Automatic, switch to turn off 2 = OCV M -Manual 3 = OCV K -Button 4 = OCV P -Permanent On 5 = OCV I -Impulse
93 Non selective cop
94
GOC GONG selection
0
0
0
0
2
10
0= no no t i n us e, e, 1 =i =i n us e, e, 2 2= = co commo n car g on ong
5
Defines operation of car ventilation. OCV A is for automatic control of the fan, with or without a switch. For OCV A and OCV AF, use 1-75 (Car Fan Saving) to set idle time for fan to turn off. If OLV N is required, set Light Type (1-98) and Fan Type (1-92) to a value of 0 (A). If OLV B is required, set Light Type (1-98) and Fan Type (1-92) to a value of 1 (AF). Non selective car operating panel in case of through type car. LCECOB board for door side B is not needed. Both doors are working by LCECOB/side-A door buttons and car calls. Landing calls are still working in selective way. Value 2 is selective cop with common car gong in case of KSS one cop in through type car.
0 = GOC not in use, directional gong 1 = directional GOC, directional GONG 2 = GOC not in use, non directional GONG 3 = non directional GOC, non directional GONG 4 = GOC not in use, advanced directional GONG 5 = directional GOC, advanced directional Selection for car gong and gong at level GONG 6 = GOC not in use, advanced non directional GONG 7 = non directional GOC, advanced non directional GONG 8= not inGOC, use, GONG 9 = GOC directional GONGnot notin inuse use 10 = non directional GOC, GONG not in use
Default
95 Drive Interface
2
0
3
0 = Parallel interface in use (V3F18/V3F25) 1 = Serial communication communication interface in use (DCBH, MCU, V3F16L, V3F25S etc) 2 = LCEDRV board in use 3 = LCEDRV board in use + G13 OPT board I/O map for ReSolve 5"
96 OSI / HSL selection
0
0
2
0=OSI, 1=HSL, 2= 2=Use up light as as OSI A
0 = Parallel interface in use (V3F18/V3F25) 1 = Serial communication communication interface in use (DCBH, MCU, V3F16L, V3F25S etc) 2 = LCEDRV board in use 3 = LCEDRV board in use + G13 OPT board I/O map for ReSolve 5" OSI indication output in FCB and OPT G02 is used either as out of service indication or here signal light.
View more...