ac9400[1].pdf

August 31, 2017 | Author: Pedro Bortot | Category: Access Control, Electrical Connector, Electronics, Electronic Engineering, Electrical Engineering
Share Embed Donate


Short Description

Download ac9400[1].pdf...

Description

AC-9400 Series

Time & Attendance / Access Control User's Manual M95-5032

Contents Information

........................................................................................... 1

Introduction ........................................................................................... 4 Technical And Operational Description .............................................. 5 Connections

..................................................................................... 16

Connection Of Multiple Units ............................................................ 27 Specifications

................................................................................... 30

Installation .......................................................................................... 31 Communication Protocol ................................................................... 33

FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communication. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Information AC9400 Access Control MACHINE TYPE

FUNCTION RFID RTC BEEP

AC-9400

AUTO TEST

OPTIONAL

28336 REC QUEUE

8096

ANTI PASSBACK

RS- 485

255

RS-232

USER CARD

80 ZONE TABLE

GNET VER 1.2

32 SENSOR TABLE

( Main Unit only )

RFID RTC BEEP

AC-9400A (With 2nd Reader : PCR943A-01) metal-wall mounting possible

AUTO TEST

RFID RTC BEEP

AC-9400B (With 2nd Reader : PCR943-01) metal-wall mounting possible

AUTO TEST

RFID RTC BEEP

AC-9400C

AUTO TEST

(With 2nd Reader : GP30W-01)

-1-

28336 REC QUEUE

8096 USER CARD

80

ANTI PASSBACK

RS- 485

255

EXT

KEYPAD& READER

RS-232

ZONE TABLE

32 SENSOR TABLE

GNET VER 1.2

28336 REC QUEUE

8096 USER CARD

80

ANTI PASSBACK

RS- 485

255

EXT READER

RS-232

ZONE TABLE

32 SENSOR TABLE

GNET VER 1.2

28336 REC QUEUE

8096 USER CARD

80

ANTI PASSBACK

EXT READER

RS-232

ZONE TABLE

32 SENSOR TABLE

GNET VER 1.2

RS- 485

255

Information

Standard Package AC-9400 Series

Access Control User's Manual

NO:123412

M95-5034

NO:123411

User's Manual ( M95-5032 )

Main unit (AC-9400 )

Wire for External Sensor /Lock/Alarm ( WAS-1466 )

Test Card ( M95-5026 )

Software Disk ( DISK5078 )

Cable for External Reader or Push button ( Egress Switch ) ( WAS-1465 )

Wall-mounting screw Kit ( ASY-M93-1049-18 )

RS-232 Cable ( WAS-1436 )

Power Adaptor DC12V/120VAC ( APR-1014 ) or DC12V/230VAC ( APR-1015A ) -2-

Screw Mounting Template ( M92-5016 )

Information

Optional

RS-485/RS-232 Converter ( CON485 )

25P Male / 9P Female RS232 Connector (CN5-1049)

RS-485 Cable ( WAS-1467 )

Cable For Multiple Connect ( WAS-1432 )

Order Information

A C 9 4 0 0

A

With 2nd Reader PCR943A-01

B

With 2nd Reader PCR943-01

C

With 2nd Reader GP30W-01 No 2nd Reader

-3-

- 0 0

U

With 120VAC Adaptor

E

With 230VAC Adaptor No Power Adaptor

Introduction AC-9400 is a highly flexible time & attendance / access control terminal. It may control the electric lock by using the RFID card. It offers reliable and future-oriented time & attendance / access control solution to meet most requirements in most areas. It can be used either as an off-line stand-alone access control unit or as an on-line access control terminal through RS-485 or RS232 interface. The major features of Model AC9400 are: Can be used either as an off-line stand-alone unit or as an on-line terminal. 4 character LED to display message, and clock time. Contain 512 K bytes Flash Memory buffer, store up to 28,336 records . Use non-volatile memory, the memory will never lose when power failure. Use proximity Card Provides RS-232 communication interfaces for remote command programming and data collection. RS-485 interface is optional. Provide two serial port connectors for daisy-chain connection of multi-unit applications, up to 255 units. Provide RS-232 communication interface. RS-485 version for long-distance connection is also available. The number of user's card can be from 000000 to FFFFFF,but maximum 8096 user's card. Personal ID number (PIN) can be from 0 to 9, 00 to 99, 000 to 999, 0000 to 9999, 00000 to 99999, 000000 to 999999. Allows 80 time table for Access control Time zone. Allows 32 time table for Sensor active Time zone. Two external drives : Drive 1 for door lock, Drive 2 for alarm. Provide a connection for indoor egress switch or one button on keypad to open the door lock from inside the room. But there is no 2nd reader when egress switch is connected. Provide a connection for door sensor to detect the door security. Provide a connection for external second card reader. Provide a 7x2 keypad to enter the PIN or to program the unit. Door lock open period is programmable from 1 to 255 seconds. Alarm active period is programmable from 1 to 65535 seconds. Can use keypad to display Firmware Version / Machine ID / Records Number / User's Card Number / Year / Month and Date / Machine Status. Use PC to set Master System Code / Machine ID / User's Card / User Time Zone / Sensor Time Zone / Door Open Duration / Clock Time / Anti-passback ON or OFF / Sensor detect ON or OFF / Baudrate...etc. Built-in Real-Time Clock (RTC) module. Door open mode can be set as " read card only" or "press keypad only" or "read card plus press keypad".

-4-

Technical And Operational Description Front Panel

1

2 3

1

DISPLAY WINDOW The display can show Time,Week Day,Status of card reading and some other messages.

2

CARD READER Approach the card here to read

3

KEYPAD To enter the PIN or to program the unit or to set some messages.

-5-

Technical And Operational Description

Rear Panel 1

2

3

4

7

5 1

6

HOST JACK For connection to the host computer or the preceding AC9400 access control unit.

2

NEXT JACK For connection to the next AC9400 access control unit.

3

EXT. RDR JACK For connection to the external second reader when the AC9400 main unit is installed inside or connection to the egress switch when the AC9400 main unit is installed outside

4

ALARM JACK For connection to the external alarm.

5

LOCK JACK For connection to the external lock.(electric strike)

6

SENSOR JACK For connection to the external door sensor.

7

POWER JACK Plug in the power for the access control . DC12V/500mA -6-

Technical And Operational Description

DISPLAY 5

3

READY

4

ERROR

1

2 SUN

MON

TUE

WED

1

TIME OR MESSAGE DISPLAY

2

WEEK DAY DISPLAY

THU

FRI

SAT

It display clock time at normal use. It will display some message when reading a card or entering PIN pad or setting parameters. It displays week day at normal use.It will display some meaning when setting parameters.

3

READY It means the machine is ready for use.

4

ERROR

5

STATUS INDICATOR

It means reading a card with error or entering PIN pad with error It shows the communication status with PC. It will blink when communication is going and message is sending.

-7-

Technical And Operational Description

Connectors on back cover

1

3

4

7

5 1

6

HOST: connect to PC or from the former unit PIN 1 2 3 4 5 6 7 8

2

2

HOST FUNCTION CTS TXD RTS RXD RS485+ SG RS485NC

PIN 1 2 3 4 5 6 7 8

RS-232 FUNCTION CTS TXD RTS RXD RS485+ SG RS485NC

PIN 1 2 3 4 5 6 7 8

RS-485 FUNCTION CTS TXD RTS RXD RS485+ SG RS485NC

PIN 1 2 3 4 5 6 7 8

RS-485 FUNCTION NC RS485SG RS485+ TXD CTS RXD RTS

NEXT: connect to next unit PIN 1 2 3 4 5 6 7 8

NEXT FUNCTION NC RS485SG RS485+ TXD CTS RXD RTS

PIN 1 2 3 4 5 6 7 8

RS-232 FUNCTION NC RS485SG RS485+ TXD CTS RXD RTS

-8-

Technical And Operational Description 3

EXT.RDR : Connect External 2nd Reader or door open push button(Egress switch) EXT. RDR PIN FUNCTION VCC * 1 VCC * 2 D1 3 D0 4 GND 5 GND 6 * Direct Connect Power Input DC12V

4

ALARM FUNCTION NO COM NC

LOCK FUNCTION NO COM NC

NO : Normal Open COM : Common NC : Normal Close

SENSOR : Dry contact relay connector for door sensor SENSOR PIN FUNCTION GND 1 SEN 2 12V 3

7

NO : Normal Open COM : Common NC : Normal Close

LOCK : Dry contact relay connector for electric strike

PIN 1 2 3

6

PUSH BUTTOM PIN FUNCTION VCC 1 VCC 2 PB * 3 PB * 4 GND 5 GND 6 * PIN3,PIN4 must Connect together

ALARM : Dry contact relay connector for external alarm

PIN 1 2 3

5

EXT.

GND : Ground SEN : Sensor Input VCC : Power Output ( Direct Connect Power )

DC12V : Power supply connector

DC 12V

-9-

10% / 500mA

Technical And Operational Description

KEYPAD OPERATION 1. Keypad Operation at "READY" standby mode 1-1. Enter Parameter Setting mode Key

F1

*

P

P

Symbol

P

P

P

P

Exp.

P

P

ENT

Master PIN number of the unit (Default :0000 )

You must enter Setting mode when you want to change the Master PIN or the Machine Address number or some parameters.

1-2. Enter Message Displaying mode Key Symbol Exp.

1-3.

F2

ENT

None You must enter Message Displaying mode when you want to see some Message, Such as Firmware Version, Machine Address, Summary of the Registered card, Summary of the Records, Year, Date (Month/ Day), Baud rate, Door Sensor ON/OFF, Lock ON/OFF, Anti-Passback ON/OFF etc.

Enter PIN number to open door Key

X

X

X

X

X

X

ENT

Symbol

X

X

X

X

X

X

Registered PIN number

Exp.

1-4.

Can be any number but maximum 6 digits.

Relieve Alarm Key

F1

*

P

P

Symbol

P

P

P

P

Exp.

P

P

ENT

Master PIN number of the unit (Default :0000 )

This is the same operation as (1-1) Paragraph,but it will relieve the alarm when the alarm is activating. It would enter Setting mode when the Machine is at normal " READY" standby mode.

- 10 -

Technical And Operational Description 1-5. One key to open door Key Symbol Exp.

ENT

None When the AC9400 main unit is installed inside the room and with the external 2nd reader installed outside and you would push one key (one button) to open door from inside, instead of reading a card, you may set the AC9400 one-key-to-open-door function to be enabled. You can press ENT one key to open the door when the one-key-to-open-door function is enabled.

2. Keypad Operation at Parameter Setting Mode 2-1.

Change Master PIN number of the unit Key

0

*

P

P

Symbol

P

P

P

P

Exp.

P

P

ENT

New Master PIN number you want.

Change Master PIN number of the unit.

2-2. Change Machine Address number Key

1

*

A

Symbol

A

A

A

Exp.

2-3.

A

A

ENT

New Machine Address number you want.

1 Machine Address number (Machine ID) Factory Default is 000 2.There are many AC9400 units connected in one network,you have to set every unit with a different Machine Address number before connected to the network. Also the Machine Address number for each unit must not be 000 .

Back to "READY" Standby Mode from Setting Mode Key

Symbol Exp.

*

*

ENT

None 1. The unit will go back to "READY" Standby Mode from Setting Mode. 2. If there is no keypad pressed or no card reading in 15 seconds, the machine will go back to " READY" standby Mode automatically.

- 11 -

Technical And Operational Description 3. Keypad Operation at Message Displaying Mode Key

Symbol

Firmware Version

Machine Address

ENT

Sum of the Registered cards

ENT

Sum of the records

ENT

Year

ENT

Date

ENT

Other Parameters

ENT

Firmware Version

The 4-digit display will show the Firmware Version of the unit. Display [1.0r0] : Firmware Version, Revised Number.

Machine Address

The 4-digit display will show the Machine Address of the unit. Display [A000] : Display Address function , Machine Address

Sum of the Registered cards

The 4-digit display will show the Summary number of the Registered Cards. Display [0000] : Total number of the Registered Cards

Sum of the records

The 4-digit display will show the Summary number of the Records. Display [0000] : Total number of the Records

Year

The 4-digit display will show the existing Year of the unit. Display [2000] : Existing Year of the Machine

Date

The 4-digit display will show the existing Date of the unit. Display [0612] : Month, Day The 4-digit display will show some other parameters. Display [-L-2] : 1st No sensor function, 2nd Lock will activate when reading a card or pressing keypad, 3th No Anti-passback function, 4th Baudrate 9600 BPS.

Other Parameters

Exp.

ENT

1.If there is no card reading or no keypad pressing in 5 seconds at Message Displaying Mode,the Machine will go back to "READY" Standby Mode automatically. 2.The operation of the Message Displaying Mode,some parameters is as below : ITEM Firmware Version Machine Address

DISPLAY DIGITAL 1 2 3 4 X.X A

r

Y

XXX

COMMENT

LED

DEC.

Firmware Version [X.X]: 1.0 ~ 9.9 Revised number [Y]: 0 ~ 9

SUN

DEC.

Machine Address [XXX]: 000 ~ 255

MON

Sum of the Registered cards

XXXX

DEC.

Sum of the Registered cards [XXXX]: 0000 ~ 8096

TUE

Sum of the records

XXXX

DEC.

Sum of the records [XXXX]: 0000 ~ 9999

WED

DEC.

Year [XXXX]: 2000 ~ 2100 Month [XX]: 01 ~ 12 / Day [YY]: 01 ~ 31

THU FRI

Year Date

XXXX XX

YY

DEC.

ITEM

Other Parameters

X

Y

Z

P

ASCII

X

Anti-passback

Y

Lock

Z

Sensor Detect

P

Baud Rate

- 12 -

Enable

Disable

A L S 0(2400BPS)/1(4800BPS)/2(9600BPS)/3(19200BPS)

SAT

Technical And Operational Description

Status and Control Displaying Enter PIN

READY

"READY" Standby Mode

X

One-key-to-open

X

X

ENT

MON

TUE

WED

ENT

ERROR SUN

MON

TUE

WED

THU

FRI

SAT

ALARMING READY

Relieve Alarm ERROR F1

*

P

P

P

P

ENT

SUN

THU

FRI

SAT

OPEN DOOR READY

ERROR SUN

MON

TUE

WED

THU

FRI

SAT

ERROR Message Displaying Mode F2

READY

ENT ERROR SUN

MON

TUE

WED

THU

FRI

SAT

STANDBY

Message Displaying Mode

Setting Mode F1

*

P

P

Back to Standy Mode

P

P

ENT

*

READY

ERROR SUN

MON

TUE

WED

THU

FRI

SAT

PROGRAMMING

Change Master PIN 0

*

P

P

P

Change Machine Address P

READY

*

1

2

3

MON

TUE

WED

ENT

READY

ERROR SUN

1

ENT

ERROR MON

TUE

WED

THU

FRI

SUN

SAT

PASSWORD

THU

FRI

SAT

ADDRESS=123

- 13 -

*

ENT

Technical And Operational Description Message Displaying Mode

Keypad ENT

READY

ERROR SUN

MON

TUE

WED

THU

FRI

SAT

FIRMWARE VERSION : 1.0R0

READY

ERROR

Keypad

SUN

MON

TUE

WED

THU

FRI

SAT

ANTI-PASSBACK : OFF LOCK ACTIVE : ON SENSOR DETECT : ON BAUDRATE : 9600 BPS

ENT

READY

Keypad ERROR SUN

MON

TUE

WED

THU

FRI

ENT

SAT

MACHINE ID : 123

Keypad READY ENT ERROR SUN

MON

TUE

WED

THU

FRI

SAT

DATE: 10/20 READY

Keypad ERROR SUN

MON

TUE

WED

THU

FRI

ENT

SAT

NUMBER OF USER CARD = 0010

Keypad READY ENT ERROR SUN

MON

TUE

WED

THU

FRI

SAT

YEAR = 2000 READY

Keypad ERROR SUN

MON

TUE

WED

THU

FRI

SAT

ENT

NUMBER OF RECORDS = 0109

- 14 -

Technical And Operational Description

READ CARD ONLY

READ CARD PLUS KEYPAD

KEYPAD ONLY

NO:123412

NO:123412

ERROR

OK

READY

ERROR SUN

MON

TUE

WED

THU

FRI

SAT

INPUT ID

OK

ERROR

READY

READY

ERROR

ERROR

SUN

MON

TUE

WED

THU

FRI

SUN

SAT

MON

OPEN

TUE

WED

THU

FRI

SAT

ER__

ERROR CODE 1 2 A 9 A 1 2 3 4 B 5 6 7 8 9

READY

ERROR SUN

MON

ER-

TUE

WED

A

THU

FRI

SAT

B

- 15 -

ERROR CODE TABLE Internal Reader External Reader Internal Keypad External Keypad Card ID not exist Time zone not fit Anti-passback error Open (Out) / Anti-passback Open (Entry) / Anti-passback Anti-passback buffer is full. Not input password Input password is error Open

Connections CONNECT TO PC

AC-9400

PC

CONNECT RS-232

RS-232 INTERFACE WAS-1436

AC-9400 PC RS-485

RS-485 INTERFACE WAS-1467 RS-232/RS-485 Converter CN5-1049

CON-485

AC-9400 PC

- 16 -

Connections

CABLE RS-232

RS-232 INTERFACE

PIN1 PIN8

WAS-1436 : LENGH - 2000 mm , WIRE - 8P8C / AWG #28

DB 9P FEMALE PIN 7 2 8 3 NC * 5 NC * NC *

WAS-1436 COLOR GRAY ORANGE BLACK RED GREEN YELLOW BLUE BROWN

RJ-11 8P8C PIN 1 2 3 4 5 6 7 8

* NC - No Connect

RS-485

RS-485 INTERFACE

PIN8

PIN7 PIN5

PIN1

WAS-1467 : LENGH - 2000 mm , WIRE - 8P8C / AWG #26

RJ-11 8P8C PIN 1 2 3 4 5 6 7 8

WAS-1467 COLOR GRAY ORANGE BLACK RED GREEN YELLOW BLUE BROWN

* CUT - Cut wire

- 17 -

WIRE CUT* CUT* CUT* CUT* 5 CUT* 7 CUT*

Connections

INTERFACE RS-232

RS-232 INTERFACE

PC

PIN 1 2 3 4 5 6 7 8

HOST FUNCTION CTS TXD RTS RXD RS485+ SG RS485NC

PLUG 1 2 3 4 5 6 7 8

WAS-1436 COLOR GRAY ORANGE BLACK RED GREEN YELLOW BLUE BROWN

DB9 7 2 8 3 NC 5 NC NC

PIN 1 2 3 4 5 6 7 8 9

PC RS232 FUNCTION DCD RXD TXD DTR SG DSR RTS CTS RI RS-485

RS-485 INTERFACE

CON485

RS-232/RS-485 Converter

PIN 1 2 3 4 5 6 7 8

HOST FUNCTION CTS TXD RTS RXD RS485+ SG RS485NC

PLUG 1 2 3 4 5 6 7 8

WAS-1467 COLOR GRAY ORANGE BLACK RED GREEN YELLOW BLUE BROWN

- 18 -

WIRE CUT* CUT* CUT* CUT* 5 CUT* 7 CUT*

PC

CON485 PIN FUNCTION 1 VCC 2 GND 3 RS4854 RS485+

Connections

CONNECT TO EXTERNAL READER

CONNECT PCR-943A-01 / PCR-943-01

PCR-943A-01

AC-9400

PCR-943-01

GP30W-01

( NOT CONNECT )

WAS-1465

BLUE BROWN ORANGE WHITE BLACK

AC-9400

RED

RED

WHITE YELLOW

GREEN

GREEN

YELLOW BLUE

BLACK

- 19 -

GP30W

Connections

CABLE PCR-943A-01 / PCR-943-01

PIN 6 PIN 1

PIN 1 2 3 4 5 6

PCR-943A-01

PCR-943A-01 / PCR-943-01 COLOR FUNCTION RED POWER BROWN POWER GREEN D1 WHITE D0 YELLOW GND BLACK GND

PCR-943-01

GP30W-01 BLUE YELLOW

PIN 6

GREEN

PIN 1

RED

RED BLACK WHITE GREEN ORANGE

BLACK

YELLOW BLUE BROWN

GP30W-01

WHITE

WAS-1465 : LENGH - 300 mm , WIRE - 6P6C / AWG #24

PIN 1 2 3 4 5 6

WAS-1465 COLOR WHITE BLACK RED GREEN YELLOW BLUE

COLOR RED BLACK WHITE GREEN ORANGE YELLOW BLUE BROWN

GP30W FUNCTION Power DC5 - 13.5V Power Ground Clock/D1 Data/RS232/D0 CP Program Input Ext. Buzzer Ext Led

* YELLOW Connect to WHITE for Wiegand Interface

- 20 -

Connections

INTERFACE PCR-943A-01 / PCR-943-01

PIN 6 PIN 1

PCR-943A-01

EXT. RDR PIN FUNCTION POWER 1 POWER 2 D1 3 D0 4 GND 5 GND 6

PCR-943A-01 / PCR-943-01 PIN COLOR FUNCTION RED POWER 1 BROWN POWER 2 GREEN D1 3 WHITE D0 4 YELLOW GND 5 BLACK GND 6

PCR-943-01

GP30W-01

PIN 6 PIN 1

GP30W-01

PIN 1 2 3 4 5 6

EXT. RDR FUNCTION POWER POWER D1 D0 GND GND

PIN 1 2 3 4 5 6

WAS-1465 COLOR WHITE BLACK RED GREEN YELLOW BLUE

- 21 -

GP30W-01 COLOR FUNCTION RED VCC BLACK GND WHITE CLOCK/D1 GREEN DATA/RS232/D0 ORANGE CP YELLOW PROGRAM BLUE BUZZER BROWN LED

Connections

CONNECT TO EXTERNAL PUSH BUTTOM

CONNECT

WAS-1465

WHITE BLACK

( NO CONNECT)

RED GREEN

YELLOW BLUE

AC-9400

PUSH BUTTOM ( EGRESS SWITCH )

CABLE LOOK " CONNECT TO EXTERNAL READER " PAGE

INTERFACE

PIN 6 PIN 1

PUSH BUTTOM EXT. RDR PIN FUNCTION POWER 1 POWER 2 D1 3 D0 4 GND 5 GND 6

WAS-1465 PIN COLOR WHITE 1 BLACK 2 RED 3 GREEN 4 YELLOW 5 BLUE 6

- 22 -

PUSH BUTTOM

Connections

CONNECT TO EXTERNAL READER + PUSH BUTTOM

+ CONNECT

CONNECT TO EXTERNAL READER

WAS-1465

Red/Brown Green White Yellow/Black

WHITE (+) BLACK RED ( D1 )

1N5819 *

GREEN ( D0 )

1N5819 *

YELLOW ( - ) BLUE

PUSH BUTTOM ( EGRESS SWITCH )

AC-9400

CABLE LOOK " CONNECT TO EXTERNAL READER " PAGE

INTERFACE

CONNECT TO EXTERNAL READER

1N5819 X 2 *

PIN 6

PIN 1

EXT. RDR PIN FUNCTION POWER 1 POWER 2 D1 3 D0 4 GND 5 GND 6

PUSH BUTTOM

WAS-1465 PIN COLOR WHITE 1 BLACK 2 RED 3 GREEN 4 YELLOW 5 BLUE 6

* 1N5819 is schottky barrier rectifiers . SPC => Io=1.0A , BVR=40V

- 23 -

CONNECT TO EXTERNAL READER

PUSH BUTTOM

Connections

CONNECT TO EXTERNAL ALARM

CONNECT

RED

ALARM POWER BLACK WHITE

ALARM

AC-9400

CABLE PIN1

WAS-1466 : LENGH - 300 mm , WIRE - 3C / AWG #18

WAS-1466 PIN COLOR RED 1 WHITE 2 BLACK 3

INTERFACE

ALARM

PIN 1 2 3

ALARM FUNCTION NO COM NC

WAS-1466 PIN COLOR RED 1 WHITE 2 BLACK 3

- 24 -

ALARM

Connections

CONNECT TO EXTERNAL LOCK

CONNECT RED

LOCK POWER BLACK WHITE

AC-9400 LOCK

CABLE

WAS-1466 PIN COLOR RED 1 WHITE 2 BLACK 3

INTERFACE

LOCK PIN 1 2 3

LOCK FUNCTION NO COM NC

WAS-1466 PIN COLOR RED 1 WHITE 2 BLACK 3

- 25 -

LOCK

Connections

CONNECT TO EXTERNAL SENSOR

CONNECT SENSOR

RED WHITE

BLACK

DOOR AC-9400

CABLE WAS-1466 PIN COLOR RED 1 WHITE 2 BLACK 3

INTERFACE

SENSOR

SENSOR PIN FUNCTION GND 1 SEN. 2 12V 3

WAS-1466 PIN COLOR RED 1 WHITE 2 BLACK 3

- 26 -

SENSOR

Connections

CONNECT TO POWER

CONNECT

AC-9400

Power Adaptor DC12V/120VAC ( APR-1014A ) or DC12V/230VAC ( APR-1015A )

INTERFACE

Power Adaptor

IN

DC 12V PIN FUNCTION 12V 1 GND 2

POWER ADAPTOR

DC 12V PIN FUNCTION 12 V 1 GND 2

EXT. RDR PIN FUNCTION OUT POWER 1 POWER 2 D1 3 D0 4 GND 5 GND 6 1. "DC12V" input power direct connect to "EXT. RDR" and "SENSOR" . 2. Power adaptor don't direct supply "ALARM" or "LOCK" power.

- 27 -

SENSOR PIN FUNCTION GND 1 SEN. 2 12V 3

Connection Of Multiple Units CONNECTION OF MULTIPLE UNITS TO PC

PC

AC-9400

CABLE

PIN8 PIN1

PIN8 PIN1

WAS-1432 : LENGTH - 1000 mm , WIRE - 8P8C / AWG #28

8P8C PIN 1 2 3 4 5 6 7 8

WAS-1432 COLOR GRAY ORANGE BLACK RED GREEN YELLOW BLUE BROWN

- 28 -

8P8C PIN 8 7 6 5 4 3 2 1

Connection Of Multiple Units

CONNECT RS-232

RS-232 INTERFACE WAS-1436

AC-9400 #1

PC

WAS-1432 NEXT AC9400 WAS-1432

AC-9400 #2

PC RS232 7 RTS 2 RXD 8 CTS 3 TXD 1 DCD 5 SG 9 RI 6 DSR 4 DTR

1 2 3 4 5 6 7 8

WAS-1432

AC-9400 #3

WAS-1436 DB9 PLUG 7 1 2 2 8 3 3 4 NC 5 5 6 NC 7 NC 8 NC

AC9400 HOST CTS 1 TXD 2 RTS 3 RXD 4 RS485+ 5 SG 6 RS485- 7 NC 8

#2 NEXT NC RS485SG RS485+ TXD CTS RXD RTS

1 2 3 4 5 6 7 8

AC9400 HOST CTS 1 TXD 2 RTS 3 RXD 4 RS485+ 5 SG 6 RS485- 7 NC 8

WAS-1432 PLUG PLUG 1 8 2 7 3 6 4 5 5 4 6 3 7 2 8 1

- 29 -

#1 NEXT NC RS485SG RS485+ TXD CTS RXD RTS

1 2 3 4 5 6 7 8

WAS-1432 PLUG PLUG 1 8 2 7 3 6 4 5 5 4 6 3 7 2 8 1

AC9400 HOST CTS 1 TXD 2 RTS 3 RXD 4 RS485+ 5 SG 6 RS485- 7 NC 8

#3 NEXT NC RS485SG RS485+ TXD CTS RXD RTS

Up to 31 units

Connection Of Multiple Units

RS-485

RS-485 INTERFACE WAS-1467

RS-232/RS-485 Converter CN5-1049

CON485

AC-9400 #1

PC WAS-1432

NEXT AC9400 WAS-1432

WAS-1432

Up to 255 units

AC-9400 #2

CON485 RS232 1 VCC 2 GND

4 RS485+ 3

RS485-

1 2 3 4 5 6 7 8

AC-9400 #3

WAS-1467 WIRE PLUG CUT 1 CUT 2 CUT 3 CUT 4 5 5 CUT 6 7 7 CUT 8

AC9400 HOST CTS 1 TXD 2 RTS 3 RXD 4 RS485+ 5 SG 6 RS485- 7 NC 8

#2 NEXT NC RS485SG RS485+ TXD CTS RXD RTS

1 2 3 4 5 6 7 8

AC9400 HOST CTS 1 TXD 2 RTS 3 RXD 4 RS485+ 5 SG 6 RS485- 7 NC 8

WAS-1432 PLUG PLUG 1 8 2 7 3 6 4 5 5 4 6 3 7 2 8 1

- 30 -

#1 NEXT NC RS485SG RS485+ TXD CTS RXD RTS

1 2 3 4 5 6 7 8

WAS-1432 PLUG PLUG 1 8 2 7 3 6 4 5 5 4 6 3 7 2 8 1

AC9400 HOST CTS 1 TXD 2 RTS 3 RXD 4 RS485+ 5 SG 6 RS485- 7 NC 8

#3 NEXT NC RS485SG RS485+ TXD CTS RXD RTS

Specifications RFID EXT

KEYPAD& READER

RS-232

RS-485

GNET VER 1.2

RTC

28336 REC QUEUE

8096 USER CARD

80 ZONE TABLE

32 SENSOR TABLE

AC

DC

% C/F

RFID Proximity Card : 125 KHZ , ASK , 64 Bits , Manchester Coding EXTERNAL RFID READER ( 2nd Reader ): 125 KHZ , ASK , 64 Bits , Manchester Coding Wiegand Interface PCR943A-01: RFID Reader with keypad,Read range 5 ~10 cm, Metallic wall workable, Temp. -10 ~ 60 C PCR943-01: RFID Reader without keypad,Read range 5 ~10 cm, Metallic wall workable, Temp. -10 ~ 60 C GP30W-01: RFID Reader without keypad,Read range 15 ~30 cm for non-metallic wall mounting, Temp. -10 ~ 60 C RS232 Interface : RS232 , Half-Duplex , 8N1 , 9600 bps Up to 15 meters / Up to 31 Units RS485 Interface : RS485 , Half-Duplex , 8N1 , 9600 bps Up to 1200 meters / Up to 255 Units on the bus Communication Protocol : GIGA-TMS Net Version 1.2 (GNET V1.2) CLOCK : Real Time Clock (RTC) module with built-in 10 year battery Clock accuracy is better than 1 minute per month at 25 C for the period of time-keeping time Memory Size for Storing Data : CMOS SuperFlash R * EEPROM 512K bytes Up to 28336 records User Cards : Up to 8096 user cards Time Zone Table : Up to 80 zone table Sensor Table : Up to 32 sensor working time table Relay Contact Capacity for ALARM And LOCK : 6A / AC 250V , 12A / DC 28VDC Electrically Life - 10 x 10 4operations. Min. Power Supply : DC 12V, 500mA Dimensions : D 52 x W 192 x H 120 mm Environment : Operating Temp : 0 ~ 55 C for AC9400 main unit -10 ~ 60 C for external readers Storage Temp : -10 ~ 55 C Humidity : 10 ~ 90 % relative Mounting : Wall-mounting

* SuperFlash is a registered trademark of Silicon Storage Technology, Inc.

- 31 -

Installation

AC-9400 INSTALLATION

5. Get the back cover and have all the necessary wires go through the back cover and then mount the back cover on the wall with 4 screws through the screw mounting template.

1. Find and get the Screw Mounting template from the box and stick the template on the wall where you want to put the AC9400 unit.

6. Connect all the necessary wries into the connectors on the main unit put the front cover as the direction from top to bottom shown on the figure sketch.

2. Drill the 4 mounting holes through the Screw Mounting template if the wall is concrete.

7. Put the front cover with the back cover together.

3. Get 4 pieces of plastic bolts to insert into the 4 holes on the wall.

8. Use the special screw driver to mount the two screws at the bottom of the unit and then stick the plastic plate to cover the screws.

4. Use the special screw driver to remove the two special screws on the bottom of the unit to separate the front cover and back cover.

9. Installation is finished.

- 32 -

Installation

PCR-943 INSTALLATION

1. Use the special screw driver to remove the two special screws at the bottom of the PCR943 unit to separate the front cover and back cover.

2. Get the back cover out of the front cover.

4. Connect all the necessary wires into the connector on the front unit and then put the front cover on the back cover as the direction from top to bottom shown on the figure sketch.

5. Put the front cover with the back cover together.

6. Use the special screw driver to mount the two special screw at the bottom of the unit.

7. Use the plastic plate to cover the two screws.

3. Put the back cover on the wall and drill the holes on the wall to mount the back cover on the wall. you must have all the necessary wires go through the back cover before you mount it on the wall. 8. Installation is finished.

- 33 -

Note 1.Do not install the external readerright on the back side of the Main unit to avoid mutual interference of the two RFID readers. If you have to install the external reader on the back side of the main unit,it must keep minimum 50 cm distance between the main unit and the external reader.

AC9400

50 cm PCR943A-01 PCR943-01 GP30

2.Better install the external reader aside from the Main unit at a distance 50 cm minimum to avoid multual interference.

AC9400 PCR943A-01 PCR943-01 GP30

50 cm - 34 -

Note 3. AC9400 SYSTEM PUSH BUTTON

EXTERNAL READER

AUX. POWER

-2C AWG #24

WAS1465 4C AWG #24

WAS1466 2C AWG #18

ALARM POWER

WAS1466 2C AWG #18

APR-1014 2C AWG #22

WAS1436 5C AWG #28

LOCK SENSOR

AC9400

WAS1465 2C AWG #24

WAS1467 2C AWG #24

SENSOR WAS-1432 2C AWG #24

WAS-1432 5C AWG #24

CON485

PC

-9C AWG #24

NEXT AC9400

GIGATMS Support wire name Minimum wire acount Minimum wire AWG No.

- 35 -

View more...

Comments

Copyright ©2017 KUPDF Inc.