AAS-28_1_11_0-RN

July 13, 2016 | Author: George Cuyang Bagsao Jr. | Category: Types, Brochures
Share Embed Donate


Short Description

Radware...

Description

Alteon Application Switch

Release Notes Version 28.1.11 August 01, 2013

TABLE OF CONTENTS

CONTENT ..................................................................................................................................................... 4 RELEASE SUMMARY .................................................................................................................................. 4 SUPPORTED PLATFORMS AND MODULES ............................................................................................ 4 OBTAINING AND INSTALLING THE SOFTWARE..................................................................................... 4 OBTAINING THE SOFTWARE ...................................................................................................................... 4 INSTALLING THE SOFTWARE ..................................................................................................................... 5 UPGRADING THE SOFTWARE .................................................................................................................. 5 WHAT’S NEW ............................................................................................................................................... 5 NEW IN VERSION 28.1.9.0 ........................................................................................................................ 5 Password Strength Policy ................................................................................................................ 5 Selecting Supported SSL/TLS Protocol Version Text ...................................................................... 6 NEW IN VERSION 28.1.7.0 ........................................................................................................................ 7 Close with RST ................................................................................................................................ 7 NEW IN VERSION 28.1.5.0 ........................................................................................................................ 7 Google Chrome Browser Official Support ........................................................................................ 7 Client-based Service Differentiation ................................................................................................. 7 GSLB in IPv6 Environment .............................................................................................................. 8 DNS Layer 7 in IPv6 Environment ................................................................................................... 8 Least Connections per Virtual Service ............................................................................................. 8 Configuration Audit ........................................................................................................................... 9 SNMP Traps for VRRP .................................................................................................................... 9 Configuration Synchronization Feedback ........................................................................................ 9 WHAT’S CHANGED AND/OR MODIFIED ................................................................................................... 9

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 2

CHANGED FEATURES IN VERSION 28.1.10.0 ............................................................................................. 9 Trap Update for Link-UP Link-Down ................................................................................................ 9 CHANGED FEATURES IN VERSION 28.1.9.0 ............................................................................................. 10 Trunk port in VRRP Hot-Standby ................................................................................................... 10 No-Password Uniqueness.............................................................................................................. 10 CHANGED FEATURES IN VERSION 28.1.5.0 ............................................................................................. 10 IPv6 Link Local Address................................................................................................................. 10 Alteon VA Management ................................................................................................................. 10 Configuration Capacity Increase .................................................................................................... 10 Downgrade Protection.................................................................................................................... 10 Layer 7 Sessions Failover .............................................................................................................. 11 SSL information HTTP Headers in 2424-SSL Format ................................................................... 11 Delete SSH Keys ........................................................................................................................... 13 Entry Level 5224 ADC-VX.............................................................................................................. 13 MAINTENANCE FIXES .............................................................................................................................. 13 FIXED IN VERSION 28.1.11.0 .................................................................................................................. 13 FIXED IN VERSION 28.1.10.0 .................................................................................................................. 17 FIXED IN VERSION 28.1.9.0 .................................................................................................................... 23 FIXED IN VERSION 28.1.8.0 .................................................................................................................... 35 FIXED IN VERSION 28.1.7.0 .................................................................................................................... 35 FIXED IN VERSION 28.1.6.0 .................................................................................................................... 38 FIXED IN VERSION 28.1.5.0 .................................................................................................................... 45 FIXED IN VERSION 28.1.2 ....................................................................................................................... 49 KNOWN LIMITATIONS .............................................................................................................................. 50 LIMITATIONS IN VERSION 28.1.10.0......................................................................................................... 51 RELATED DOCUMENTATION .................................................................................................................. 55

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 3

Content Radware announces the release of Alteon Application Switch version 28.1.11.0. These release notes describe new features since the last released version of 28.1.5.0. Alteon Application Switch 28.1.11.0 includes all bug fixes from maintenance version 28.1.5.0.

Release Summary Release Date: July 22, 2013 Objective: Minor software release addressing software issues.

Supported Platforms and Modules This version is supported on the following Alteon platforms:        

4408 running on OnDemand Switch™ VL 4408 XL running on OnDemand Switch VL XL 4416 running on OnDemand Switch 2 4416 running on OnDemand Switch 2 XL 5224 running on OnDemand Switch 3 LS 5224 running on OnDemand Switch 3 LS XL 5412 running on OnDemand Switch 3 5412 running on OnDemand Switch 3 XL

For more information on platform specifications, refer to the Alteon Installation and Maintenance Guide. This version is supported by APSolute Vision version 1.25 and later.

Obtaining and Installing the Software This section describes how to obtain and install the software for this version.

Obtaining the Software 1. Go to www.radware.com and log in if prompted. Note: You must have a username and password before attempting to download a software update. If you do not have a username and password, click My Account and then click Register. 2. Under My Updates > Software Releases, the set of products and software downloads for which you have licenses display. 3. For the release version and platform you want to update or recover, select the Download Software icon, and download the relevant software update or recovery files to a server within your own organization that is accessible using FTP or TFTP.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 4

Installing the Software For details on installation, refer to the Alteon Installation and Maintenance Guide.

Upgrading the Software For details on upgrading, refer to the Alteon Installation and Maintenance Guide. You can upgrade to this version from any of the following previous AlteonOS versions:        

26.0.x 26.1.x 26.2.x 26.3.x 26.8.x 27.0.x 28.0.x 28.1.x

What’s New This section describes the new features and components introduced in this version. For more details on all described capabilities, refer to the Alteon Application Switch Operating System Application Guide and the Alteon Application Switch Operating System Command Reference for this version.

New in version 28.1.9.0 Password Strength Policy

Administrators are now able to configure parameters that ensure only strong passwords. The password strength enforces:    

Minimal password length Specific characters Complexity Password validity (maximum/minimum age) Password History.

Note: The strong password policy is not applied on main Administrator (admin username), but is applied on user-defined users with Administrator role. NFR number: prod00158348

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 5

Selecting Supported SSL/TLS Protocol Version Text

Alteon Application Switch provided the ability to select the allowed and disallowed SSL/TLS protocol versions in both frontend and backend connection. Disallowed SSL/TLS protocol version will be rejected before handshake start. Use-cases examples:  

Mitigate the BEAST by allowing only SSLv3 and TLS1.1 in the SSL Policy. To completely reject any SSLv2 connection to pass PCI compliance testing (SSLv2 handshake failure on non-matching ciphers as it is done today is non-PCI compliant)

>> HTTPS Server Access# /cfg/slb/ssl/sslpol 1 -----------------------------------------------------------[SSL Policy 1 Menu] name - Set descriptive policy name passinfo - Pass SSL Information to Backend Servers Menu frver - Allowed Frontend SSL Protocol Version Menu bever - Allowed Backend SSL Protocol Version Menu cipher - Set allowed cipher-suites in frontend SSL intermca - Set Intermediate CA certificate chain becipher - Set allowed cipher-suites in backend SSL authpol - Set client authentication policy convuri - Set Host regex for HTTP redirection conversion bessl - Enable/Disable backend SSL encryption convert - Enable/Disable HTTP redirection conversion ena - Enable policy dis - Disable policy del - Delete Policy cur - Display current policy configuration >> SSL Policy 1# frver/ -----------------------------------------------------------[SSL Policy 1 frver Menu] ssl3 - Enable/Disable frontend SSLv3 protocol version tls10 tls11 cur

- Enable/Disable frontend TLS1.0 protocol version - Enable/Disable frontend TLS1.1 Protocol version - Display current frontend SSL protocol version configuration

>> SSL Policy 1# bever/ -----------------------------------------------------------[SSL Policy 1 bever Menu] ssl3 - Enable/Disable backend SSLv3 protocol version tls10 - Enable/Disable backend TLS1.0 protocol version tls11 - Enable/Disable backend TLS1.1 Protocol version cur - Display current backend SSL protocol version configuration

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 6

Note: SSLv2 is disabled by default in both frontend and backend connections NFR number: prod00161360

New in version 28.1.7.0 Close with RST

When enabled, upon receiving FIN from either side (client or server), Alteon closes the other side using RST. This causes the session entry to be removed immediately. When disabled, upon receiving FIN, graceful closure is performed in both sides. Default: disable Close with RST can be set per virtual service. Note: To enable, forceproxy must be enabled on that service NFR number: prod00162646

New in version 28.1.5.0 Google Chrome Browser Official Support

Google Chrome Browser (version 17.x and later) is added to the list of supported BBI platforms.

Client-based Service Differentiation

Alteon lets you provide differentiated services for specific client groups: different type of services, different levels of service, and different service access rights. To implement this feature, source network classification has been added to the Layer 3 service classification as part of virtual server definition. For example, in order to provide differentiated HTTP/S services for two separate groups of clients, you need to configure the following:    

Source Network nw1 Source Network nw2 Virtual Server 1: VIP 100.100.100.100, Source Network nw1 o Service HTTP: Group 1 o Service HTTPS: Group 1; SSL Policy ssl1 Virtual Server 2: VIP 100.100.100.100, Source Network nw2 o Service HTTP: Group 2 o Service HTTPS: Group 2; SSL Policy ssl1

If, for example, you want to allow only HTTPS service for nw2 users, no HTTP service would be configured for Virtual Server 2.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 7

The new Network object type enables configuring complex networks for use in source network classification. A network object can include and/or exclude multiple IP subnets and/or ranges. The following is an example for the subnet definition described above: 



nw1: o o o

Include 100.100.90.0/255.255.255.0 Include 100.100.950.0/255.255.255.0 Include 100.100.20.0 – 100.100.40.255

nw2: o o o o

Include 100.100.0.0/255.255.0.0 Exclude 100.100.90.0/255.255.255.0 Exclude 100.100.950.0/255.255.255.0 Exclude 100.100.20.0 – 100.100.40.255

Note: This new capability is currently only configurable via CLI and BBI.

GSLB in IPv6 Environment

Global Server Load Balancing is now supported for IPv6 environments. This support includes:     

Support for AAAA query resolution that allows resolving a hostname to an IPv6 address. Support for IPv6 GSLB networks to enable using the Network metric for IPv6 clients. Support for IPv6 communication between remote sites. New DSSP version (version 5) that provides support for IPv6. DNSsec support for AAAA queries

Note: This new capability is currently only configurable via CLI and BBI.

DNS Layer 7 in IPv6 Environment

Layer 7 load balancing (according to hostname, query type, or DNS versus DNSsec type) is now also supported for DNS UDP in an IPv6 environment (IPv6 clients and servers).

Least Connections per Virtual Service

The Least Connections per Virtual Service group metric is an extension of the current Least Connections metric. It allows for real server selection based only on the number of active connections for the service which is load balanced, and not the total number of connections active on the server. For example, when selecting a real server for a new HTTP session, a real server serving one HTTP connection and 20 FTP connections takes precedence over a real server serving two HTTP connections only.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 8

Note: This feature was first introduced in version 26.3.1.0.

Configuration Audit

Alteon lets you log the details of all configuration changes to the syslog servers. Note: Enabling this feature may increase the Management Processor (MP) CPU usage temporarily if the configuration changes are very large. Note: This feature was first introduced in version 26.3.1.0.

SNMP Traps for VRRP

SNMP traps are sent when a VRRP virtual server router (VSR) changes status to either master or backup. Note: This feature was first introduced in version 26.3.1.0.

Configuration Synchronization Feedback

Feedback on success or failure of Global Admin configuration synchronization has been added. Reports are received on success or failure of synchronization with each peer.

What’s Changed and/or Modified This section describes changes to existing features and components introduced in this version.

Changed Features in version 28.1.10.0 Trap Update for Link-UP Link-Down

The trap information of linkDown and linkUp were updated and added with the following information:   

ifName – return “Port ”, for example, Port 1. agPortCurCfgPortName – return the port name as defined at "/c/port x/name”. agPortCurCfgPortAlia - return the port alias as defined at under "/c/port x/alias".

With this change, the linkDown and linkup traps return the following MIBs in this: altSwTrapDisplayString, ifIndex, altSwTrapSeverity, ifName, ifOperStatus, ifAdminStatus, agPortCurCfgPortName and agPortCurCfgPortAlias. NFR number: prod00170474

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 9

Changed Features in version 28.1.9.0 Trunk port in VRRP Hot-Standby

In a VRRP Hot-Standby configuration, a trunk port is now considered as failed and its priority is changed only when all the ports in the trunk are down. NFR number: prod00167723

No-Password Uniqueness

In case of pre-defined user password is changed from its default and no local users define, both user name and password will be prompted upon login instead of only for password NFR number: prod00161402

Changed Features in version 28.1.5.0 IPv6 Link Local Address

The following enhancements were made to Link Local Address support:  

Manual configuration of a VLAN Link Local Address An address of type Link Local can be configured in a static route Gateway parameter.

Alteon VA Management

Alteon VA can now be managed through VMware API and File System.

Configuration Capacity Increase

The maximum number of configurable instances was increased for the following objects:   

The maximum number of TCP scripts has been increased to 256. The maximum number of static routes has been increased to 1024 The maximum number of GSLB networks for has been increased to 1024

Downgrade Protection

In order to mitigate crash-loops due to configuration parameters that are not supported in earlier versions, after downgrading from version 28.1.x the configuration is restored to factory defaults (preserving IPv4 management interface access). Starting with this version, after downgrading from a version later than 28.1.5.0, the device will perform Apply verification after booting up with the earlier version.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 10

Layer 7 Sessions Failover

In order to ensure fast Layer 7 session failover to a new master device, the new master device now induces clients to resend Layer 7 requests upon failover by sending a reset to the client when requests are received over connections established with the old master.

SSL information HTTP Headers in 2424-SSL Format

In this release, the optional HTTP headers that carry SSL and SSL-based client authentication information can be set to be in 2424-SSL compatible format. This new functionality eases the migration of Web applications that used 2424-SSL for SSL offloading to AlteonOS 28.1.5.0, by eliminating the need to change the Web application header parsing. The new headers format is available when changing the comply command to enabled in one of the following paths:  

/cfg/slb/ssl/sslpol/passinfo /cfg/slb/ssl/authpol/passinfo

The following table compares HTTP Headers formats between versions: Location

Info Type

2424-SSL

28.15 when comply disabled

28.15 when comply enabled

SSL Policy

Cipher-suite

N/A

Cipher-Suite: AES256-SHA

Cipher-Suite: AES256-SHA

SSL Policy

SSL Version

N/A

SSL-Version: TLSv1/SSLv3

SSL-Version: TLSv1/SSLv3

SSL Policy

SSL Cipher Bits

N/A

Cipher-Bits: 256

Cipher-Bits: 256

SSL Policy

SSL complied info

X-SSL: decrypted=true, ciphers="TLSv1/SSLv3 RC4-SHA”

N/A

X-SSL: decrypted=true, ciphers="TLSv1/SSLv3 RC4-SHA"

SSL Policy

IIS front-end HTTPS

Front-End-Https: on

Front-End-Https: on

Front-End-Https: on

Authentica tion Policy

Client Certificate issuer

X-SSL:

CCRT-Issuer:

X-SSL:

peerissuer="emailAddr [email protected] m,CN=CT10,OU=CT1 00,O=Radare,L=NA,S T=NY,CUS"

/C=US/ST=NY/L=NA/O=Rad wae/OU=CT100/CN=CT100/ emailAddress=ct100@radw are.com

peerissuer="emailAddress= [email protected],CN=C 100,OU=CT100,O=Radwar, L=NA,ST=NY,C=US"

Authentica tion Policy

Client Certificate subject name

X-SSL:

CCRT-Subject:

X-SSL:

peersubject="emailAdd ress=ct100@radware. com,CN=User_0002,O

/C=US/ST=NY/L=NA/O=Rad ware/OU=CT100/CN=User_ 0002/e

peersubject="emailAddress [email protected],CN= User_0002,OU=CT100,O=

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 11

Location

Info Type

2424-SSL

28.15 when comply disabled

28.15 when comply enabled

U=CT100,O=Radware, L=N,ST=NY,C=US"

mailAddress=ct100@radwar e.com

Radware,L=NA,ST=NY,C= US"

Authentica tion Policy

Client Certificate serial number

X-SSL: peerserial=3

CCRT-SN: 03

X-SSL: peerserial=03

Authentica tion Policy

Client Certificate SSL version

N/A

CCRT-Version: 3

CCRT-Version: 3

Authentica tion Policy

Client Certificate signing algorithm

N/A

CCRT-SignatureAlgo: md5WithRSAEncryption

CCRT-SignatureAlgo: md5WithRSAEncryption

Authentica tion Policy

Client Certificate not valid before

N/A

CCRT-NotBefore: Oct 12 18:05:37 2010 GMT

CCRT-NotBefore: Oct 12 18:05:37 2010 GMT

Authentica tion Policy

Client Certificate not valid after

N/A

CCRT-NotAfter: Oct 12 18:05:37 2011 GMT

CCRT-NotAfter: Oct 12 18:05:37 2011 GMT

Authentica tion Policy

Client Certificate Public key type

N/A

CCRT-publicKeyType: RSA(1024 bit)

CCRT-publicKeyType: RSA(1024 bit)

Authentica tion Policy

Client Certificate HASH

N/A

CCRT-MD5Hash: 9311345EB64A9D5968AF6 A471D480431

CCRT-MD5Hash: 9311345EB64A9D5968AF6 A471D480431

Authentica tion Policy

Full client cert

X-Client-Cert: -----BEGIN CERTIFICATE----MIIDfjCCAue...XZKw= = -----END CERTIFICATE-----

CCRT-Certificate: MIIDfjCCAue...XZKw==

X-Client-Cert: -----BEGIN CERTIFICATE---- MIIDfjCCAue...XZKw== -----END CERTIFICATE----

Header names are configurable in AlteonOS 28.x so they can be adjusted to comply with 2424SSL fixed header names easily in configuration. Note: This feature was first introduced in version 27.0.1.0.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 12

Delete SSH Keys

SSH keys can now be deleted when reconfiguring the device from the /boot menu. Note: This feature was first introduced in version 26.3.1.0.

Entry Level 5224 ADC-VX

Alteon 28.1.5.0 supports entry-level ADC-VX (maximum of 10 vADCs) on 5224 with 12 GB RAM. Important! This offering is only available in the Americas region, for special promotion.

Maintenance Fixes This section lists all fixed issues that were reported by the field personnel or mentioned previously as known limitations or bugs in versions starting from version 28.1.0. Later versions contain all fixes of earlier versions unless otherwise noted.

Fixed in version 28.1.11.0 Item

Description

1.

Using the APSolute Vision client, configuration sync between two Alteon platforms sometimes caused the Alteon initiating the sync to crash. Using APSolute Vision client, it was not possible to set a the Server Group ID in virtual services other than HTTP and HTTPS IPv6 scripted health check did not close the TCP session in case of multiple open and close actions in the same script. When issuing the 'save' command through the XML API interface, Alteon crashed. Using the BBI, it was not possible to configure the USM User Name (an SNMPv3 parameter). In a mixed IPv4 and IPv6 environment, after session entries aged, Alteon sometimes crashed. In a mixed IPv4 and IPv6 environment, after session entries aged, Alteon sometimes crashed. On an Alteon 5000 and 4416, in standalone mode, the throughput usage calculation was incorrect, causing false throughput alert messages to be sent. In VRRP hot standby mode, when the ISL port was set to disabled on the backup Alteon, all hot standby ports on the backup remained in DISABLED status and did not change to FORWARDING status. With dbind enabled, the ICMP unreachable (Fragmentation Needed) packet was forwarded to the server with the

2. 3. 4. 5. 6. 7. 8. 9.

10.

Bug ID

prod00189736

prod00189732 prod00189690 prod00189552 prod00189302 prod00189144 prod00189143

prod00188880

prod00188830 prod00188730

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 13

Fixed in version 28.1.11.0 Item 11.

12.

13.

14.

15. 16. 17.

18.

19. 20.

21.

Description incorrect SEQ number. After rebooting a vADC, with connection management configured on a service and its associated server port defined with VLAN-based PIP, the entire configuration (except the management configuration ) displayed in the diff. In VRRP hot standby mode, when using trunk ports in ISL ports and in client or server-side ports, when all ISL ports were down all of the client and server side ports on the backup Alteon changed to FORWARDING statues, causing a Layer 2 network loop. After the Global Admin changed the backdoor settings for a vADC user, the backdoor command did not display in the Global Admin configuration dump and also did not display in the vADC. When Alteon received a ping destined for a network broadcast address, Alteon sent the ping reply with source MAC address of ff:ff:ff:ff:ff:ff instead of the interface MAC address. After rebooting a vADC with static ARP entries configured, the entire configuration displayed in the diff. After the admin password was changed in the configuration, the password displayed in clear text in diff and diff flash. After Alteon was up for about 200 days, it sometimes experienced the following behavior: - 100% SP CPU utilization - Full system freeze - Sudden system reboot with no panic trace These issues seemed to occur without any network changes, traffic patterns changes, user intervention, or any other direct reason. When configuration auditing using TACACS+ was enabled, the following issues occurred: - The commands under the /cfg/sys/mmgmt menu were not logged when entered in a single line. - When configuration was performed using an SSH session, no commands were logged. When a feature license was enabled on a vADC, a vadcLicGlobal trap was generated but the vADCNewCfgFeatBWM OID was missing. After Alteon rebooted with no space on the hard disk, the configuration that had certificate and keys was not handled correctly, resulting in the entire configuration displaying in the diff. After upgrading from version 26.x to 28.x or 29.x, attempting to connect to the platform from APSolute Vision resulted in

Bug ID

prod00188476

prod00188370

prod00188348

prod00188176 prod00188160 prod00188159

prod00187911

prod00187747

prod00187636

prod00187467 prod00187168

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 14

Fixed in version 28.1.11.0 Item

22. 23. 24.

25.

26.

27. 28. 29.

30.

31. 32. 33.

Description an error because APSolute Vision could not retrieve the device driver from Alteon Using an SSH connection, uploading a configuration that that defined SSHv1 as disabled changed the SSHv1 setting to enabled (default). A high rate of packets with invalid TTL (value 0,1) that are processed by the device could cause health check flip-flops, VRRP flip flops, due to high MP CPU uitilization. When setting the DST time zone to the Canada/EasternOntario-&-Quebec time zone and the NTP Timezone Offset (tzone) was +0:00, the NTP Daylight Saving Time (DST) was not adjusted correctly. When traffic was processed through the Application Engine, after VRRP failover an outage sometimes occurred. This was because of RST or FIN packets sent by Alteon on sessions that started on the main platform and which failed over, using the VR MAC instead of the interface MAC ("confusing" the Layer 2 switch). When accessing device via TACACS authenticated user in some rare cases the TACACS server closed the connections at the same time the device TACACS request timed out and it caused panic on the device. After uploading an image using SCP, the subsequent file transfer via SCP (such as get configuration0), sometimes caused Alteon to crash. Using the BBI with a RADIUS authenticated user whose name length was longer than 21 characters, after logging out of BBI Alteon panicked. SIP Load Balancing did not work with fragmented requests. SIP requires that all fragments are first buffered and then makes the load balancing decision. Because the last fragment was dropped, the load balancing decision was not be performed. When the configuration included a group for which backup group is defined and a group with no backup defined, whose ID was higher than the ID of group with backup defined, and the traffic was processed by Acceleration Engine, when the group that has backup was down, the servers in the backup group appear as not in service, even though they are available, resulting in 503 error response to clients. A DSR ICMP health check failed on servers running Windows 2008R2 SP1. Sessions handled by the Application Engine were not aged, if within 60 seconds after the FIN packet was sent by the server it also sent a SYN (as a result of RST). When using an SSH management connection, Alteon experienced instabilities.

Bug ID

prod00187123

prod00187051

prod00186863

prod00186846

prod00186821

prod00186670

prod00186667

prod00186644

prod00186573 prod00186546

prod00186501 prod00186464

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 15

Fixed in version 28.1.11.0 Item

Description

34.

On an Alteon 5412 platform, the throughput was limited to 10G instead of 20G. When ADC-VX restarted after a crash or intentional panic (using /maint/panic), Alteon experienced instabilities. Using SNMP, the temperature threshold was incorrect. When using TACACS+ Authentication, after entering user credentials, sometimes the connection using SSH stacked and no CLI prompt appeared. Using the BBI, a trap on a login failure attempt was not generated. In VRRP hot standby mode, after a port was operationally disabled and then enabled, the port configuration enable/disable command did not work properly. On a backup platform, operationally disabling a hot standby SFP port did not work. GSLB HTTP redirection did not work for an HTTPS service. Using URL SLB, when the GET URL split over multiple TCP segments, the URL string matching was performed only on the first segment, resulting in incorrect matching. In version 28.1.8.x, after setting the re-ARP period and applying and saving in its old path (/cfg/l3/ip) instead of its new path (/cfg/l3/arp), after reboot the command to set the re-ARP period was disabled. Per second Interface statistics displayed incorrect values. The export tech support dump command did not prompt to provide the file name with a .tar extension. In a vADC, the memory utilization output (/stats/sp/mem) always displayed 0 Kbytes. The Last apply and Last Save times were not updated when receiving the configuration from a peer switch during a sync operation. In some cases, sending BPDIs on the external port failed due an internal issue, when this happened, debug printouts appeared on the console.

35. 36. 37. 38. 39. 40. 41. 42. 43.

44. 45. 46. 47. 48.

49.

Using NAT filter, ICMP "Destination Unreachable" messages response were not processed by Alteon , as session creation and response happened to be on different SP's.

Bug ID prod00186287 prod00186261 prod00186095

prod00186092 prod00185928

prod00185423 prod00185419 prod00178810

prod00177975

prod00174075 prod00161478 prod00156435 prod00156430

prod00156326

prod00190184

prod00186201

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 16

Fixed in version 28.1.10.0 Item

Description

Bug ID

50.

When the application service log was set to debug level, a GET/POST request containing %s or %s arrived, causing Alteon to crash.

prod00185487

51.

52.

53.

54.

55.

56. 57.

When the time zone was set to a location where DST (Daylight Saving Time) is applicable but not in effect, on every reboot the time moved back by one hour. If after reboot the time changed to a value earlier than the certificate issued time, the error server certificate not yet valid displays.

prod00185363

In a session that had a number of GET requests where the cookie is bound to a server in down state, the first GET request was redirected to another server that was in up state, while the other GET requests were sent incorrectly to the first server which was in down state.

prod00177865

Configuration changes for TCP and content class trace log were incorrectly applied. As a result, warning messages regarding the Application Services Trace Log performance impact were potentially sent every few hours even after all logs were disabled.

prod00177729

The description for some MIBs related to real server statistics per SP were updated to reflect their "per SP" relation.

prod00185158

In force proxy mode, when the client sent a FIN and the server answered with an RST, fastage was not activated on the session entry.

prod00177443

Throughput license alerts only worked on the Alteon 4408 platform and not on any of the other platforms.

prod00177506

Resize of the vADC file system: ========================== In VX versions as 28.1.2.0 and below, the vADCs were allocated with a low size as ~7.5MB instead of having more than 50MB. This caused inability to capture traffic on the vADCs As upgrade doesn't change the size allocated in previus version to vADCs, we introduce the command /maint/debug/resizevadc The command will check if vADC resize is needed.

prod00179399

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 17

Fixed in version 28.1.10.0 Item

Description

Bug ID

If so, the user will be asked to confirm the process will being informed that requires system reboot which may take up to 1.5 hours. Resize operation on 28.1.10.0 changes the vADCs size to ~100MB Note: USB Recovery procedures to these versions will also allocate the right sizes to the vADCs 58. 59. 60. 61.

62.

63.

64.

65.

66.

67.

After reboot, the ISL VLAN configuration for a vADC was moved to pending state .

prod00177682

When the resolution was set to one hour or one day, the ADC-VX dashboard displayed incorrect statistics.

prod00178193

When a real server and Alteon VA resided on the same ESX, HTTP health checks failed.

prod00179128

When using a passive cookie, dbind forceproxy, and the hash metric, if the cookie value did not match any session entry, the cookie value was used as the key to select the real server instead of using the source IP.

prod00184579

The administrative user with the Service user class could not display any information or statuses of the real servers for which the administrative user was defined as the owner.

prod00138330

After the NTP time zone was modified using /cfg/sys/ntp/tzone, the system time zone was not updated.

prod00150654, prod00174180

VRRP advertisements were still sent even when all ports were down, causing the advertisements counter (/stat/l3/vrrp vrrpOutAdvers) to continue to increase.

prod00157795

The output of the /info/l3/route/dump command displayed internal debug information irrelevant to Alteon end-users. This output now only appear only in God mode.

prod00164538

In Global admin mode, the incorrect stat/vadc X/sp Y/mem command syntax was accepted. The correct syntax is stat/vadc X/sp/mem.

prod00177262

In Alteon VA VMware version 28.1.9.0, high MP CPU utilization was always observed even though the actual

prod00185069

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 18

Fixed in version 28.1.10.0 Item

Description

Bug ID

CPU utilization was low. 68.

69. 70.

When vstat was enabled, the virtual service octets counter wrapped around at the 4,294,967,295 value (32-bit).

prod00185606

The user-defined cipher parameter was incorrectly limited to 64 characters.

prod00178811

When a NAT filter was configured, traceroute failed because ICMP TTL Exceeded Timeout (ICMP type 11) packets that arrived with NAT address as the destination IP, were dropped.

prod00178853, prod00185053

71.

If several virtual servers had the same VIP, when a real server returned an HTTP redirection, an internal tunnel port was added to the location header. prod00178751

72.

After applying and saving a configuration that was uploaded over a factory default setting, an incorrect message displayed stating that there may be unapplied configuration changes, even though all changes were applied.

prod00179387

Using BBI, a virtual router could be deleted while still being a member of a VR group.

prod00178423

When dbind was enabled on a service, the session timeout was set to the value configured on the real server instead of using the timeout configured on the virtual service.

prod00179486

vADC SP memory statistics did not function. They always displayed 0.

prod00177007

If multiple virtual servers shared the same VIP, when the virtual server with a higher index was deleted the Virtual Server Router (VSR) of that VIP was stuck in the INIT state.

prod00177399

The SNMP trap always were sent to the default port (162) regardless of the configured port number.

prod00185083

On an Alteon VA platform using BBI, it was possible to install a new image to the active image slot.

prod00185159

When the Inter-Switch port was down, the hot-standby ports that belonged to a trunk kept their STG state as LISTENING after boot-up, even though STG was set to

prod00185612

73. 74.

75. 76.

77. 78. 79.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 19

Fixed in version 28.1.10.0 Item

Description

Bug ID

off. 80. 81. 82.

83.

84.

85.

86.

87.

88. 89.

The following MIB objects appeared twice in the MIB file: agTftpImageAdc and agTftpImageVx

prod00184976

Using BBI, a virtual server with the UDP stateless protocol displayed as TCP.

prod00184977

The content class element Hostname/Path/Filename/Filetype did not match an empty value.

prod00185431

In case of script health check, where the expected response string is bigger than 40 chars, if a health check bigger than 60 chars did not match the expected string, the device crashed.

prod00184908

In a configuration where the Hot-Standby ports belong to a trunk on both client and server network, in case all the ISL ports were down, a L2 network loop occurred

prod00179395

In case of a multiple request connection arrived to a virtual service configured with HTTP content modification and connection management, If the second request arrived at the same time the service cannot respond (service down or in 100% CPU for example), the device may crash.

prod00178731

Traps vadcStateUp, vadcStateDown, vadcStateShutdown and vadcStateRestart were removed from the MIB file as they are not supported.

prod00178727

When TACACS+ logging is enabled, in some cases when performing apply from the CLI alone with TAB, before hitting enter, the device may crash.

prod00177992

In some cases, configuration synchronization from the VX caused the backup VX to crash

prod00185644

When application service log was set to debug level, a GET/POST request containing %s or %s arrived caused the Alteon to crashed. prod00185316

90.

91.

Setting application service modules log level to none did not change the TCP module log level to none as well.

prod00185168

From performance reasons, we have removed the

prod00185738

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 20

Fixed in version 28.1.10.0 Item

Description

Bug ID

mechanism that automatically changes the application log level to debug in case of large amount of messages per session arrives. 92. 93.

Using the BBI to download an image more than once via HTTPS, occasionally caused Alteon to crash.

prod00174597

The following changes were made due to BDPU packet loss in Alteon VX: - You can now use the /c/sys/acc/rlimit command to limit the number of BPDUs handled per second per port on Alteon VX. - The default BPDU limit was changed to zero (unlimited). In previous versions it was hard-coded to 5 BPDUs per second per port for Alteon VX, and to 5 BPDUs per second per port for standalone Alteons. - A counter was added to show the number of BDPU packets dropped in Alteon VX and can be found at /stats/vx/counters. - Alteon vADC now accepts all rlimit values, except for BPDUs (which are processed in Alteon VX).

prod00176509

94.

An incorrect trap (vADCInfoStatus) was generated from GA upon vADC reboot. prod00173256

95.

Redirect persistent sessions were not aged out when rport was configured with the filter.

prod00174261

When RTS was enabled on client port, the RTS sessions were wrongly created on all SPs, causing the sessions on the non-relevant SPs to persist and not aged out.

prod00174301

The management port became inaccessible when the management connection was closed before TFTP upload/download tasks via the management port (such as support dump and configuration dump) had ended completely.

prod00177406

It was not possible to add a GSLB IPv4 remote site via Vision. An error related to IPv6 was incorrectly

prod00175919

96.

97.

98.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 21

Fixed in version 28.1.10.0 Item

Description

Bug ID

generated. 99. 100.

101.

102.

103. 104. 105. 106.

107.

108. 109.

110. 111.

In some cases it was not possible to download the cached content.

prod00176971

In a configuration were the data port gateway and a real server had the same IP address, and both had an ARP health check, the gateway frequently lost its connectivity, causing the VIP to become inaccessible.

prod00177212

Redirection to HTTPS requests failed if the virtual service was defined with an HTTPS redirection action which using "$QUERY", and the requests to redirect contain an odd number of characters in the string.

prod00175362

After changing the real server operational status to disable and then to enable, its state changed to block although its health check succeeded.

prod00175800

Traps altSwcpuCross80 and altSwcpuFell80 are now obsolete.

prod00173561

Incorrect trap OIDs were sent for vADC throughput limit, vADC ssl limit, and vADC compression limit.

prod00173851

When a VRRP status change occurred on vADC, an incorrect trap OID was sent.

prod00173921

Applying a content rule in a virtual service sometimes failed when the rule was not added in the consecutive numerical order to rules already applied. For example, applying rule 6 failed where rules 5 and 7 were already running.

prod00174209

Using the BBI to upload a new image to the active image bank caused Alteon to become non-bootable and require USB recovery.

prod00176870

Incorrect trap host address was shown under /info/sys/snmp/taddr.

prod00174552

ColdStart (sent on startup) and WarmStart (sent on reset) traps were not generated in Alteon versions after 28.x.

prod00176003

When a feature license was enabled on vADC, an incorrect trap OID was sent.

prod00174181

When vADC was deleted, the vadcDelete trap was not generated.

prod00174183

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 22

Fixed in version 28.1.10.0 Item

Description

Bug ID

112.

When capacity units where added or removed from vADC, the vadcCapUnit trap was not generated.

prod00174185

When setting the Alteon health check content in the group to a value longer than 127, no warning appeared although Alteon did not accept this content.

prod00174273

In a standalone Alteon, when trying to set the BWM user table size using the BBI, an incorrect message sent stating that the maximum allowed entries is 16K entries per SP.

prod00174400

115.

A RADIUS/TACACs+ secret password including "!" disappeared from configuration after reboot.

prod00175349/ prod00175631

116.

For WAP SLB with RADIUS persistence, group statistics showed that all traffic was sent to one server, although the traffic was actually load balanced between several servers.

prod00174693

113.

114.

Fixed in version 28.1.9.0 Item

Description

1.

In version 28.1.8.40, when uploading the configuration with a private key, the key extraction failed because the passphrase was not parsed correctly. prod00174411

2.

In version 28.1.8.20, the redirection filter with client proxy processing enabled did not work.

prod00174272

When a SIP service with no SIP parsing was used, various configuration additions (such as adding a filter, adding Layer 7 parsing for other services, disabling local DAM) caused session failures on that SIP service.

prod00174120

HSRP tracking did not work-- the priority was not increased.

prod00173856

When some services used the legacy delayed binding and some used forceproxy, under stress, the HTTP 503 error message could appear on the proxied session due to server selection failure.

prod00173770

Using the BBI, when configuring the intermediate certificate name, the device panicked.

prod00173754

3.

4. 5.

6.

Bug ID

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 23

Fixed in version 28.1.9.0 Item

Description

Bug ID

7.

After switching to verbose 1 mode, a service configured in verbose 2 mode was erroneously changed to basic-slb.

prod00173750

8.

9.

10. 11.

12.

13.

14. 15.

16. 17.

When the scpadmin user on a TACACS server had the same password as the scpadmin on the device, logging in with the scpadmin user caused 100% CPU usage. In addition, it was not possible to login with any username that had the same password as the scpadmin user.

prod00173687

Least connection load balancing on a real server port (rmetric) did not work with SLB IPv6-to-IPv4. All of the requests were load balanced to the first rport of the server.

prod00173370

SIP load balancing did not work when DAM was enabled globally and disabled under the service.

prod00173282

The SNMP Trap Source IP setting was not taken into account and was not set as the trap source. Instead, the first interface that was UP was considered to be the trap source.

prod00173274

On traffic matching the IPv4 redirect filter with proxy processing enabled on the port, and no PIP address defined, Half NAT was not performed. Half NAT was performed correctly for the same configuration processing IPv6 traffic.

prod00173219

When the device rebooted with an expired certificate in its configuration, after the reboot all the configuration remained in pending state.

prod00172948

In session dumps collected via SNMP, the EAcc and Acc flags were missing.

prod00172918

Sessions collected via SNMP were not showing correctly when session entries were deleted or aged during the collection process.

prod00172917

On the 5224 platform, incorrect temperature thresholds were displayed.

prod00172904

In an ADC-VX environment, creating or changing Layer 2 configuration items such as trunks or VLANs caused all the VIPs on the VADCs to stop function for up to 30

prod00172709

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 24

Fixed in version 28.1.9.0 Item

Description

Bug ID

seconds. 18. 19.

20.

21.

22.

23.

24.

25. 26.

27.

28. 29. 30.

It was not possible to delete session entries by using the slbOperSessionDelete SNMP SET command.

prod00172596

Because in version 27.x, the default protocol for DNS and SIP services was changed from TCP to UDP, after upgrading from version 26.x to 28.x, configuration changes in the protocol setting occurred.

prod00172595

Using the Chrome browser, Alteon did not release the TCP connection created by opening HTTPS management to the device via a data port.

prod00172310

Removed the /boot/udefquit command on console/telnet/ssh because rebooting the device from the console using Shift + Ctrl + "-" is not supported on OnDemand Switch platforms.

prod00172213

Using BBI or APSolute Vision, it was not possible to export a configuration with private keys. It is now possible on HTTPS and SNMPv3 connections.

prod00172196

Virtual service statistics did not display the content based-service rules statistics when the service port was different than 80.

prod00172059

When accessing the device via BBI using the nondefault OPER user, the Class Of Service is displayed as USER instead of OPER.

prod00172057

After an SNMP request to 802.1AB LLDP OIDs, VRRP flip flopped.

prod00171983

After configuration sync, the order of the virtual services section in the configuration dump was different in the sending peer than in the received peer.

prod00171762

In a VRRP pair configuration with DNSSSEC enabled, configuration sync could cause both peers to be set with keyslave enabled.

prod00171761

After executing the /stats/sp/c +[tab] command in the fourth Telnet/SSH session, the device crashed.

prod00171758

In version 28.1.8.30, a revert apply with an interface address change could cause the device to hang.

prod00171609

The BPDU frame length for RSTP and MSTP BPDUs was incorrect -- Alteon indicates a frame 14 bytes

prod00171399

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 25

Fixed in version 28.1.9.0 Item

Description

Bug ID

longer. 31.

32.

33. 34.

35.

Using BBI, when a real server or virtual server was added to the GSLB metric, the preference value was set to 0. Now you can define network preferences values using BBI.

prod00171391

In a VRRP owner configuration, editing or deleting the interface IP address or VIR address did not update the interface MAC address to the base MAC address.

prod00169623

After applying configuration changes that affected the routing table, the device sometimes panicked.

prod00169133

Due to unnecessary validation during boot-up, the vADC configuration was not applied automatically and instead moved to “diff”. Manual apply was then required to make it active.

prod00162680/ prod00170875

It was not possible to delete an IPv6 management interface.

prod00160336

36.

When an apply command was performed in parallel with a configuration change done from another CLI interface, the CPU utilization increased.

37.

When the passphrase configured for certificate sync contained an "!" character, the configuration was not loaded after reboot.

prod00171765

When force proxy was used, the default BWM contract (ID 1024) did not work, as well as application acceleration capabilities and SSL acceleration.

prod00171616

38.

39.

When Alteon inserted an x-forwarded-for header and dbind is set to enabled, a client request corruption occurred. When dbind is set to force-proxy, this client request corruption does not occur.

40.

prod00171441

If one of the ports in a trunk was down, the trunk was declared down for port teaming. In this version, the trunk is now considered up for port teaming if at least one trunk port is up.

41.

prod00156307

prod00171252

Alteon did not process the HTTP CONNECT method. After a service with application acceleration configured received the CONNECT method, the service closed the prod00171244

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 26

Fixed in version 28.1.9.0 Item

Description

Bug ID

connection by sending [FIN,PSH,ACK] to the client. 42.

43.

When rport load-balancing was used with pbind cookie and dbind force proxy, virtual server statistics were incorrect

prod00171178

When receiving multiple GET requests in the same TCP session that matched both cookie persistency and URL SLB and that were designated to different real servers, the persistence sessions that were created were not removed from the session table, causing the session table to fill up

prod00170976

44.

On a device with an ADoS license and DoS attack enabled on the port, ICMP type 3 packets (destination port unreachable) where considered as ICMPLEN DOS attacks, causing the MP CPU to reach 100%. prod00170909

45.

After migrating from the 2424 platform to the 5412 platform, WTS load-balancing did not work. This happened because of the difference between the CPU chips used in each platform and the way the IP addresses are stored in memory.

prod00170776

With GSLB set to enabled, HTTP access set to disabled, and wport set to 80, it was not possible to apply a configuration.

prod00170745

When real server backup with preemption were disabled, because an apply causes a server to either go up or down, when the backup server health check arrived before the primary server health check, the backup took over even though the primary was still alive.

prod00170723, prod00170456

46.

47.

48.

The command description for importing and exporting a certificate component was improved prod00170462

49.

In a configuration with the same real server with preemption disabled was associated to multiple groups that function in different virtual services, if the primary server failed, the backup server took over only in one group.

50.

prod00170454, prod00170317

Configuring real server backup with preemption disabled created tje following problems: 1. Preemption disabled did not work for some real servers (depending on their index).

prod00170453, prod00170067

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 27

Fixed in version 28.1.9.0 Item

Description

Bug ID

2. If the primary server came up before the backup (for the first time after reboot), and the server went down then up again, preemption acted as if it was enabled. 51.

52.

53. 54.

55. 56.

57. 58.

59.

After failover, on the ex-Master, the status of some primary servers with backup preemption disabled changes to operator DISABLED and backup server took over.

prod00170451

Using a redirect filter, if a real server with preemption enabled failed, its backup real server took over and acted as if preemption was disabled when the primary real server came back up (traffic was still sent to the backup server even though the primary was up).

prod00170374

Network class deletion was not synced to a peer switch.

prod00170347

backup group real server showed in service info output as "group dis, up" and no traffic sent to that real although the backup group was up. This happened when the primary group went down and the backup group became active and then 2 more groups were added using the same real server from the backup group

prod00170175

In an ADC-VX environment, MSTP/RTSP was not working.

prod00169943

In a vADC environment, a tsdump command caused a VRRP to flip flop (meaning that the backup became master and after a short time became the backup again) and all services defined on that vADC went down.

prod00169942

Throughput information showed much higher values than the actual throughput.

prod00169940

When an IP fragment ping was sent to a VIR, VIP, or VSR, the interface MAC address was used as the source MAC of the ping reply.

prod00169338

When the IP address of a VIP was changed, the ARP entry with the old VIP address was not removed even though there was no other VR with the same address as the old VIP.

prod00169334

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 28

Fixed in version 28.1.9.0 Item

Description

60.

On an OnDemand Switch 3 platform, traffic from source TCP ports 4 or 5 displayed incorrectly in the session table, as follows:

Bug ID

1. Aged-out sessions still appeared in the session dump 2. Live sessions were displayed incorrectly as BWM sessions. Their source IP addresses and ingress ports appeared as 0.

prod00169037

SLB VIP was added automatically to the OSPF database and distributed to the peers even though the default route redistribution was configured (no host redistribution defined).

prod00168364

When entering a new virtual service menu without changing anything under that menu, Alteon considered it as a configuration change even though diff was empty.

prod00167509

63.

Wrong FAN failure Syslog messages were sent while the tsdmp showed FAN OK.

prod00153747/ prod00153290

64.

In a vADC environment, after importing a configuration without its private key, even though the apply was successful after the import it was not possible to access the server certificate menu.

prod00156551

In DSR mode, ICMP health checks were sent to real server IP rather than to sending it to the loopback address (the VIP IP address)

prod00170244

SIP session entry was not aged properly in a case where INVITE reuses a session that was already deleted/moved to fastage.

prod00169941

67.

Network mask of localnet was not displayed properly

prod00169609

68.

When using configuration with multiple interfaces, the device became inaccessible, within 5 minutes from upgrade to 28.1.8.20

prod00169565, prod00169455, prod00169458

69.

SNMP Get/GetNext request to 1.3.6.1.2.1.2.2.1.3.x caused the Alteon to enter freeze state. Reboot was needed to exit this state.

prod00169455

70.

BPDUs of disabled VLAN were flooded on all ports.

prod00169555

71.

Alteon device sometimes panicked after applying

prod00169333

61.

62.

65.

66.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 29

Fixed in version 28.1.9.0 Item

Description

Bug ID

configuration changes that affected routing table. 72.

HTTP traffic affected by vADC SSL CPS limit.

prod00169253

73.

After running SNMP traffic for some time, all management activities became inaccessible due to a memory leak

prod00169141, prod00169111

SNMP services became down after upgrade. That happened due to a changed added in SMTP Health check in version 28.1.8.10. Now, SMTP HC made common for both IPV4 and IPV6, meaning that SMTP HC will send a "vrfy" even if there is no content is configured. Some SMTP servers does not reply to "vrfy" since they are waiting for additional data and therefore can be considered as down

prod00169052

vADC reset occured when accessed a virtual service of type ''service ip''.

prod00169012

In a URL redirect from HTTP to HTTPs setting, GET request without the host header caused the device to crash

prod00168862

When adding PIP for port range via BBI, an error message appeared

prod00168757

Passive cookie persistency with rport load-balancing, when the cookie is not found and the client request is within the same TCP connection, rport persistency was not maintained

prod00168751

Health Check Script above 156 caused the virtual service to go down for several seconds

prod00168588

HTTP content class and http modification did not work together when both made a decision according to HOST header

prod00168515

81.

SIP outbound call was not working

prod00168443

82.

It was not possible to define Script health check between 64 to 256

prod00168271

83.

nonat on RTSP virtual service was not working.

prod00166915

84.

Some syslog messages on management port were missing, No message was sent after the management IPv6

prod00166720

74.

75. 76.

77. 78.

79. 80.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 30

Fixed in version 28.1.9.0 Item

Description

Bug ID

gateway address and therefore it was thought to be not UP 85.

86.

In hot-standby environment, when there are more than 256 VSRs, the following syslog message appeared in the backup: "vrrp: received incorrect addresses"

prod00165484

Querying the vADC interface using a 64-bit counter MIB returned a value of 0.

prod00162440

87.

A change in the Layer 3 configuration caused the default gateway status to flap.

prod00168365

88.

After upgrade, the pending configuration message displayed even though no pending configuration existed.

prod00167780

With the TACACS+ command login enabled, after executing an Alteon global command (such as save, apply, or diff. Alteon sometimes crashed.

prod00167541

When a hot-standby port was not part of VLAN assigned to the vADC, it was not tracked for VRRP priority.

prod00167398

91.

An IPv6 VIP responded with the incorrect source MAC address.

prod00167397

92.

In a DNS hostname configuration using regular expressions, uppercase characters were always changed to lowercase.

prod00167326

93.

On a 4408 platform, sometimes a FAN status alert was sent for non-existing fans.

prod00167173

94.

When a Layer 7 DNS string was configured to match at the end of the chain (using the $ symbol), if the string existed twice in the DNS query, it was considered to be no match.

prod00167152

95.

Alteon dropped broadcast ARP replies with a unicast target MAC address.

prod00167139

96.

In an ADC-VX environment, the OID of vadcStateVrrpMaster / vadcStateVrrpBackup trap was incorrect.

prod00167105

97.

The TACACS usernames did not display in the login syslog message.

prod00166917

98.

In an ADC-VX environment, in the BBI dashboard the

prod00166916

89.

90.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 31

Fixed in version 28.1.9.0 Item

Description

Bug ID

SSL CPS information was incorrect. 99.

On a 4408 platform, during upgrade a “file missing” error message displayed.

prod00166885

100.

The SNMP trap for link up and link down was not clear and did not indicate the port number and its state.

prod00166805

101.

When the Technical Support dump was issued via SSH and the terminal immediately closed without writing the prod00166745 output, Alteon would sometimes crash.

102.

In a vADC, when its two CUs were located on the same SP core (with a different HAID),a VRRP advertisement conflict occurred .

prod00166743

After issuing the "session clear" command, sessions that were removed on the master were not cleared on the backup.

prod00166740

104.

NTP requests were not sent from an IPv6 management port.

prod00166538

105.

Using BBI, when exporting all VX and vADC configurations, the vADC configurations were not restored properly.

prod00166537

On a 5224 platform using BBI, the displayed management IP was different than the one configured in CLI.

prod00166536

107.

The Spain daylight savings timezone was incorrect.

prod00166534

108.

An IPv6 VR did not reply to ICMPv6 requests.

prod00166453

109.

ICMPv6 router advertisements were not dropped by the deny filter.

prod00166448

110.

Configuration synchronization was not working

prod00166199

111.

Redirection filters did not work correctly when proxy was enabled on the port and the filter was defined with rport, even though no proxy IP was configured in the filter.

prod00165876

112.

OSPF static/fixed selective route redistribution using route maps did not work.

prod00165847

113.

Latency occurred due to a high port reuse rate.

prod00165578

114.

In a VRRP hot-standby configuration, when the ISL link went down, the IP interface also went down on the

prod00165487

103.

106.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 32

Fixed in version 28.1.9.0 Item

Description

Bug ID

backup vADC. 115.

Script health checks were not allowed for an IP type virtual service.

prod00164543

116.

In a VRRP hot-standby configuration, when the master vADC panicked (booted up very quickly), the failover was not performed properly.

prod00162893

117.

After importing a file that contains more than one certificate, Alteon crashed.

prod00160343

118.

The SNMP trap for link up/down did not indicate the related port number.

prod00167018

119.

Using RTSP SLB, TRCP and RTP sessions were not cleared from the session table on

prod00166549

time. 120.

On a 5412 platform, when manually disabling an SFP copper port, the link did not go

prod00166339

down on the peer switch. 121.

When multiple VIPs used the same real server, in the traffic that returned to the client

prod00166243

that caused a session failure, the real server IP to VIP translation was wrong. 122.

On an Alteon 10000 platform, an irrelevant reboot log appeared.

prod00166207

123.

Rarely, after upgrading to version 28.1.5.0, an HTTP 1.0 request from a proxy caused

prod00166193, prod00166980

the device to crash. 124.

In a filter with session table caching disabled and tunable hash based on the source or

prod00165795

destination IP, group redirection did not occur. 125.

When setting the backup group for a group with no real server, an unclear message

prod00165506

displayed. 126.

When the request header was larger than 16K, SSL decryption failed.

prod00165389

127.

When DSR was configured, many sessions were created for a single HTTP request,

prod00165358

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 33

Fixed in version 28.1.9.0 Item

Description

Bug ID

causing the session table to fill up even though the load was minimal. 128.

BWM statistics sent to an SMTP server configured on a data port caused a device panic.

prod00165357

129.

On an Alteon 5412 platform with 32GB memory, a client request that reached 50K TPS

prod00165275

caused the device to crash. 130.

When compression was used along with multiplexing, an HTTP 1.0 client, and server

prod00165251, prod00166979

keep-alive, transactions did not finish because a FIN was not sent by the server. 131.

SSHv2 management connection did not work with a Sun Solaris client.

prod00165231

132.

SSH management on data port caused a device panic.

prod00165216

133.

When a second HTTPS request arrived on an existing TCP session, Alteon sent the

prod00165016

request to the same real server selected for the first HTTPS request without checking if there was a new URL SLB match. 134.

Using BBI, configuring port mirroring caused the Alteon device to panic.

prod00164932

135.

In a redirect filter with session caching disabled, when all the real servers were down,

prod00164910

the packets were dropped instead of being forwarded to the default route 136.

When SNMPv1 and v2 where disabled, Alteon answered SNMPv1 requests with an

prod00164896

error message instead of not answering at all. 137.

The td-config and shared maintenance debug commands were available in normal mode

prod00164787

instead of being available only in god mode. 138.

CISCO PVST and BPDU frames were not always tagged when sent out from a tagged

prod00164731

port. 139.

Alteon did not forward BPDU frames in VX mode.

prod00164710

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 34

Fixed in version 28.1.9.0 Item

Description

Bug ID

140.

In a GSLB environment, when more than 10 VIPs were configured with the same

prod00164708

domain, the device panicked on a DNS response for that domain. 141.

The real server state was not set to block when one of the services it served was down.

prod00164632

This happened when the real server was defined with multiple addports associated with 142.

Only ICMP health check can be used for virtual service for type IP

prod00141916

Fixed in version 28.1.8.0 Item

Description

Bug ID

1.

Configuration synchronization was not working

prod00166199

2.

BPDUs were not always tagged when sent out from tagged port

prod00166164

Fixed in version 28.1.7.0 Item

Description

Bug ID

1.

Using IPv6 script health checks resulted in high MP CPU usage.

prod00164420

On an Alteon 5412 platform, LACP packets were dropped by Alteon VX.

prod00164305

On the Alteon 5412 and 5224 VX platforms, when STP was set to off, STP and LACP packets were not forwarded.

prod00164227

On an Alteon 5412 platform, STP packets were dropped by Alteon VX.

prod00164223

It was not possible to connect using Vision to Alteon 28.1.6.0

prod00164196

The SLBadmin user was unable to apply configuration changes.

prod00164136

2. 3.

4. 5. 6.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 35

Fixed in version 28.1.7.0 Item

Description

Bug ID

7.

When session caching was enabled, IPv6 filter redirection did not work.

prod00164003

Synchronization of DNSSEC configuration changes were automatically performed on apply, even though no peers were configured.

prod00163824

When Layer 7 modification was defined, dbind was automatically changed from enabled to forceproxy.

prod00163767

The SSH management connection became inaccessible periodically, and running SSH on/off did not revive the connection. After several such retries, the device reset.

prod00163531, prod00163229

On an Alteon 5224 platform, BWM was not working on ports 17 through 26.

prod00163417

On an Alteon VX 5224 platform, in viewing the vADC in the BBI, there was a mismatch between the VLAN table and the Physical Ports table.

prod00163394

On a Alteon VX 5224 platform, in the BBI L2 Physical Port pane, the port speed of ports 19 through 24 displayed the incorrect values.

prod00163392

Alteon VX crashed in certain cases due to SSH management connection.

prod00163271

8.

9. 10.

11. 12.

13.

14. 15.

16.

NAT was not performed on SDP data (in SIP) with response codes other than 200OK Now it is also performed for 180 RINGING and 183 SESSION IN PROGRESS response codes.

prod00163262

ADC-VX could capture traffic from only one vADC at a time. Now separate files are saved for each vADC.

prod00163247

17.

When 1. creating a disabled virt, adding a content class rule to it, and applying it, and then 2. enabling the virt and applying it again, Alteon replied with a "503" HTTP response code (=servers down) when matching the content class, even though the servers were actually up. prod00163224

18.

In a Layer 2 DSR environment, DNS UDP health checks caused the device to crash. Upgrade from 27.0.3 to 28.x results in panic once VRRP activated.

prod00163185

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 36

Fixed in version 28.1.7.0 Item

Description

Bug ID

19.

Using RADIUS authentication, SSH user access was blocked for an unlimited time, even though it was defined as authorized.

prod00163112

In APSolute Vision, the secure cookie insert configuration showed opposite settings from the device

prod00163098

When the ADC-VX and the vADCs were installed with different versions, vADC sync failed.

prod00163077

In the BBI, an incorrect breadcrumb appeared in the Layer 3 sub-menus.

prod00163017

When VRRP failover occurred, it took the default gateway 8 seconds to get back online.

prod00162931

Using SCP to transfer the configuration and commands to Alteon did not work on ADC-VX/vADC.

prod00162738

When the device was under heavy load, sometimes FDB table corruption occurred, causing ARP and ICMP packets to be discarded.

prod00162636

After adding a couple of interfaces, the device panicked.

prod00162562

Some of the SSH/Telnet management connections were not closed properly in vADC, causing the maximum commotion (4) to be reached. As a result, new management connections could not be opened.

prod00162450

Querying the vADC interface using a 64-bit counter MIB returned a value of 0.

prod00162440

It was not possible to set a virtual service IP supporting both UDP and TCP protocols in the same service.

prod00162382

Executing many putdumps commands sometimes caused ADC-VX to crash

prod00162230

Adding a second VIP with RTSP SLB that uses the same real server as the first RTSP SLB service caused the sessions to the first VIP to fail.

prod00162090

An empty "name" in the "team" configuration dump caused restoring the configuration to fail.

prod00162051

33.

Dynamic proximity calculation results were incorrect.

prod00162044

34.

When exporting the configuration using the putdump command, the user password displayed in clear text.

prod00161980

20. 21. 22. 23. 24. 25.

26. 27.

28. 29. 30. 31.

32.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 37

Fixed in version 28.1.7.0 Item

Description

Bug ID

35.

Using the BBI, in a VRRP service based group, it was not possible to disable share and preempt.

prod00161975

Using the BBI, it was not possible to change an SSL service rport to 443 when back-end SSL was disabled.

prod00161441

Virtual service statistics were incorrect for services with dbind enabled and pbind set to sslid

prod00161245

Some validation checks for matching between the server certificate and private key were missing.

prod00160917

The output of the real server group mapping command (/info/slb/bind) was incorrect.

prod00157497

36. 37. 38. 39.

Fixed in version 28.1.6.0 Item

Description

Bug ID

1.

When cookie insert for persistency and Layer 7 string matching were configured in an HTTPS offloading service, and the traffic did not contain any matching cookie or string, a server was selected instead of responding with HTTP error 503 (server unavailable).

prod00162602

With a heavy load of HTTP "Connection: close" traffic and connection management enabled, software panic sometimes occurred when several responses were sent from the server for one request.

prod00162148

When the port command was retransmitted, Active FTP load balancing did not work properly.

prod00162078

Under certain circumstances, unpredictable behavior occurred with certificate management (such as loss of keys, unable to connect via SSH, the diff flash holds the configuration after reboot, and so on).

prod00161974

When a client HTTPS request did not match any of the strings assigned to the real servers, after Alteon reset no response was received and SSL terminated.

prod00161818

When the GSLB network IP version was not manually defined, the proximity GSLB worked incorrectly.

prod00161647

The redundant capability of setting an SNMP service with TCP protocol was removed.

prod00161584

2.

3. 4.

5.

6. 7.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 38

Fixed in version 28.1.6.0 Item

Description

Bug ID

8.

The configuration apply command generated incorrect and irrelevant VRRP syslog messages.

prod00161579

Transferring a large file using an HTTPS service took much longer compared to an HTTP service, because a small TCP window size was set.

prod00161459

For virtual services configured with SSL offloading where the front-end and back-end ports are the same, the service back-end port on the backup device was changed during configuration synchronization.

prod00161446

Using VRRP with stateful failover configured, when the backup device booted up after upgrading to version 28.1.5, the master device rebooted repeatedly.

prod00161442

In version 28.1.5.0, when X-Forwarded-For was using with dbind enabled, the sequence number on the second get request to server was incorrect.

prod00161266

In version 28.1.2.0, an image upgrade via HTTP transport caused a panic.

prod00161254

In BBI, a clear operation in SLB monitoring cleared the session table instead of clearing SLB statistics

prod00161019

In an HTTP persistency configuration, the path was added to the cookie header even though it was not configured in the pbind cookie insert configuration.

prod00161011

The connection splicing statistic was not updated with dbind forceproxy.

prod00161007

Alteon panicked when "host:" string was not found in the URI of a request.

prod00160900

The RADIUS secret password was synced during configuration sync.

prod00160668

When all the real servers in a group and backup group were down, the virtual server information displayed the backup group as disabled.

prod00160637

On Alteon with SSL acceleration card, a very heavy load can cause a switch panic

prod00160610

The swkey (license information) command did not display the installed default throughput license.

prod00160459

A non-updated Geo database was used, causing Geo IP resolution for a DNS query to be incorrect.

prod00160397

9.

10.

11.

12.

13. 14. 15.

16. 17. 18. 19.

20. 21. 22.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 39

Fixed in version 28.1.6.0 Item

Description

Bug ID

23.

In certain cases, out-of-order fragments traffic with proxy IP configured caused the device to crash.

prod00160348

After upgrading from version 28.0 to 28.1, an apply failed due to a certificate synchronization error, even though no certificate was configured.

prod00160341

Active FTP load balancing did not work properly when PORT command retransmission occurs.

prod00160294

On a virtual service with both caching and compression policies, when compression was set disabled, caching also stopped working

prod00160249

After USB recovery, redundant message appeared before the login prompt

prod00159887

On on Alteon 5224, STP and LACP packets that were received on ports without a VLAN tag configured were dropped.

prod00159860

In a vADC hot-standby configuration with Layer 4 switch port tracking enabled, resetting the master vADC caused the backup vADC to take over only until the master vADC started again.

prod00159834

session matched on redirect filter with Linklb and FTPA enabled where created with ageing 0 and got disconnected quickly

prod00159775

On 4408/4408-XL devices, throughput license information showed irrelevant value when default throughput license was installed

prod00159763

It was possible to set the default gateway address to a virtual server and PIP.

prod00159741

In a vADC, server responses with the destination MAC of a different vADC were not processed and were then dropped.

prod00159723

During image download on VX, LACP trunks where blocked for about 2 minutes causing network traffic instability

prod00159550

When persistent entry exists but corresponding real server was down or disabled, Alteon answered with HTTP Error 503 (Service unavailable) instead of selecting new server

prod00159531

24.

25. 26.

27. 28.

29.

30.

31.

32. 33.

34.

35.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 40

Fixed in version 28.1.6.0 Item

Description

Bug ID

36.

When TCP based health checks (i.e HTTP, FTP) were configured for UDP based services, TCP port health check was performed instead of ICMP

prod00159427

The ADC-VX MIB-II did not support 64-bit counters. ADC-VX interfaces were incorrectly displayed as 10/100 instead of Gigabit or 10Gigabit.

prod00159381

In curtain cases, Direct Server Return (nonat enabled) caused switch panic

prod00159357

SSL session failed after configuration apply due to certificate synchronization

prod00159323

BBI showed incorrect user login information when login-in from the same host with different users which has the same COS

prod00159298

PIP statistics update of VLAN based PIP, caused the vADC to crash

prod00159297

In an ADC-VX environment, XL devices were not indicated as XL in CLI displays.

prod00159257

Switch panicked when real comes back up causing the backup real servers to become disabled

prod00158835

Navigation option between the Virtual Servers BBI pages was missing

prod00158669

After disabling connection management functionality in a service, a persistency problem occurred.

prod00158650

Active FTP load balancing did not work properly because of the wrong adjustment to the sequence number

prod00158622

When static route is not covered by localnet, default gateway will be used. Removed confusing warning message appeared in such cases

prod00158609

Update of server certificate name via BBI was not possible

prod00158590

Active FTP load balancing did not work properly due to wrong adjustment of the sequence number

prod00158572

50.

Certain SNMP traps caused the device to crash

prod00158525

51.

Virtual server current session statistics, showed strange value via BBI

prod00158470

37.

38. 39. 40.

41. 42. 43. 44. 45. 46.

47.

48. 49.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 41

Fixed in version 28.1.6.0 Item

Description

Bug ID

52.

It was not possible to disable SSL offloading for a VIP via BBI

prod00158456

Responses from Virtual Server were linked to the same port of the trunk and therefore limit the throughput to 1 Gbps. This happened since the trunk load balancing algorithm used only source IP instead of source IP + destination IP

prod00158403

Enable "IP TOS matching" on a filter through BBI also enabled the "IP Option Matching"

prod00158281

Empty trunk name appeared in the configuration dump caused failure in restoring configuration

prod00158111

53.

54. 55. 56.

On a 5412 platform, TACACS+ authentication caused the device to crash.

prod00157976

57.

In BBI, the Alteon-VX dashboard did not work. Also, HTTP request over management port with an empty Host header caused the device to crash

prod00157799

58.

VRRP flap occurred when uploading tech support dump or viewing real servers information on backup vADC1.

prod00157771

59.

On 4408 and 4416 devices, the putdumps maintenance command failed.

prod00157731

60.

On a 5412 platform, the device crashed with a link load balancing configuration with fragmented traffic.

prod00157666

61.

In CLI and BBI displays, an Alteon 4408 device with an SSL card was not identified as 4408XL.

prod00157617

62.

Heavy load caused Alteon to sent irrelevant trap (OCSP related)

prod00157309

63.

When "regex" or "none" where incorrectly defined as the HTTP modification element, a panic occurred.

prod00157033

64.

The default compression license for 5224XL was changed from 500 Mbps to 1Gbps.

prod00157011

65.

On device startup, a duplicate SNMP temperature trap was sent where one of the messages had incorrect information.

prod00156974

66.

When only one power supply was installed in a dual power supply device, an SNMP trap reporting this problem was not generated.

prod00156903

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 42

Fixed in version 28.1.6.0 Item

Description

Bug ID

67.

After upgrading to version 28.1.5, all vADCs went down and their image statuses were displayed as Incompatible.

prod00156868

68.

In SNMP traps sent on data port, the wrong agentaddress was included, and the incorrect OID was reported in slbCurCfgRealServerOid.0

prod00156813

69.

In a vADC environment, when the syslog default port was configured on a management port, the source IP address of the syslog packets was the ADC-VX management IP instead of the vADC management IP.

prod00156720

70.

Persistency break sometime occurred when a cookie arrived to an SP which did not contain the persistent entry of that cookie

prod00156706

During configuration sync, port number was replaced with port allies causing a problem in VRRP failover

prod00156661

When all primary servers were configured as disabled, the backup servers moved from the blocked to the up state when one of the backup servers was disabled operationally.

prod00156636

71. 72.

73.

In certain cases, active FTP LB with client NAT did not work.

prod00156619

74.

When VLAN based PIP was configured, no PIP statistics were generated.

prod00156548

75.

An Apply generated incorrect and irrelevant VRRP syslog messages.

prod00156531

76.

In a vADC, a user with CoS set to user was unable to enable or disable the real servers that were assigned to him, while the l3oper user was able to do enable or disable real servers that were not assigned to him.

prod00156384

77.

After upgrading from version 28.0 to 28.1, an apply failed when VRRP hot-standby was configured.

prod00156344

78.

The string "v4" was mistakenly added to the SMTP hostname in the configuration dump.

prod00156070

79.

False fan traps were sent on a vADC.

prod00155948

80.

When a vADC was down, BPDUs in corresponding VLAN were not blocked.

prod00155824

81.

After upgrading from version 27.0.x to 28.1.2.x, An

prod00155794

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 43

Fixed in version 28.1.6.0 Item

Description

Bug ID

apply failed when X-ForwardedFfor configured for a service. 82.

Throughput license is up to 16 Gbps for the 5224 and 5224XLplatforms. This was incorrectly stated in previous release notes.

prod00155691

83.

After upgrade from 27.0.2.0 to 28.1.2.0 with dbind disabled and X-Forward-For enabled, after changing dbind to enabled on a service, an error message was issued, and the device crashed.

prod00155689

84.

A vADC panic caused the SYS LED to turn red. Only rebooting the device turned the LED back to green.

prod00154297

85.

During the upgrade process of a cluster, after one device was upgraded from version 28.0. to 28.1, the cluster changed to the VRRP Master-Master state.

prod00153379

86.

A link UP was reported on port with the Copper SFP module inserted, even though the cable was not connected.

prod00152580

87.

vADC throughput statistic was shown in MB rather than Mbps

prod00152104

88.

When attempting to reset a vADC or device, a message is issued that there is an unapplied/unsaved configuration even though the configuration was applied and saved.

prod00151807

89.

An NTP server IP address could not be deleted (set to default 0.0.0.0 value).

prod00151632

90.

After SSH login, the SSH management session sometimes hangs.

prod00151316

91.

In dbind forceproxy service, If the client delayed in sending the FIN,ACK to Alteon as a response to FIN, the session entry was aged in slow aging rather than fast aging

prod00151145

92.

After applying system configuration changes, incorrect SLB log messages were issued.

prod00151057

93.

When an IPv4 VRRP group was enabled, it was possible to define an IPv6 VSR. This caused the IPv6 VSR to be unreachable.

prod00150485

94.

When connection management was enabled and

prod00141402

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 44

Fixed in version 28.1.6.0 Item

Description

Bug ID

egress PIP was configured (as recommended), Alteon still required the ingress PIP address to be configured.

Fixed in version 28.1.5.0 Item

Description

Bug ID

1.

The switch blocked TCP sequence zero and direct ARP request (non broadcast) packets, treating them as attack packets.

136092

2.

SSL offloading with SSL reuse did not work properly on Alteon 5412 XL.

155194

3.

When delayed binding was enabled, an HTTP request with malformed HTTP version parameter caused a panic.

155172

4.

When performing SNMP walk of the Alteon switch MIB, the walk stopped once it reached the agAccessNewCfgHttpsCert.0 (1.3.6.1.4.1.1872.2.5.1.1.19.4.6.0) OID.

153699

5.

When a configuration included real servers with buddy servers, after Apply unnecessary notices regarding server statuses were sent.

153555

6.

The virtual server status was reported via BBI as blocked when one real server went down.

153554

7.

When delayed binding was enabled, an HTTP request with malformed HTTP version parameter caused a panic.

153491

8.

When Alteon 5224 ports 1 and 2 are administratively disabled (/cfg/port x/dis), the links connected to Alteon 5224 ports 3 and 4 went down.

153297

9.

Performing the /maint/applog/showlog command caused a vADC restart, and no panic dump was available.

153167

10.

A Header Modification rule to remove the Date header did not remove the header from HTTP requests.

152927

Could not enable SSH from Telnet in 28.1.2.0.

152888

The upgrade from version 27 to 28 failed if the device

152803

11.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 45

Fixed in version 28.1.5.0 Item

Description

Bug ID

configuration included certificates. 12.

A panic occurred on a vADC when a SAVE command was performed via SNMP.

152787

13.

When Web cache redirection and server load balancing were performed using a filter with a non-zero server port (rport), the server port was not updated in the session table resulting in a session failure.

152506

14.

Even though a vADC management port was locked by the Global Administrator, the vADC management port could be deleted by pasting a script without a management setting.

152487

15.

When changing proxy IPs and virtual servers using BBI, the device panicked.

152226

16.

The default SSL CPS license was incorrectly set to 500 CPS for Alteon 5224XL.

152224

17.

When an interface was disabled and then enabled, OSPF did not recover after the link came back up.

152132

18.

MNG-2 management port could be configured but did not work properly. Currently this port cannot be configured.

152131

19.

Interface statistics showed incorrect values.

152056

20.

Load balancing between device gateways using the round robin metric did not work properly and resulted in uneven allocation.

152044

21.

When attempting to reset a vADC or device, a message displayed that there was an unapplied/unsaved configuration even through the configuration has been applied and saved

151807

22.

Load balancing of WTS traffic caused a panic on the device.

151681

23.

Alteon VA responded to ping to VIR only when the request came from the VLAN to which the VIR belonged.

151590

24.

When configuring the NTP primary server with an empty string, a fake IPv6 address was set as the server address.

151407

25.

When NTP servers were connected behind a gateway,

151406

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 46

Fixed in version 28.1.5.0 Item

Description

Bug ID

an NTP warning message was displaying the gateway address instead of the NTP server IP address. 26.

The device did not allow enabling egress PIP (epip) on a service when the server-side port was proxy enabled but was not assigned a PIP.

151019

27.

VRRP group settings could not be configured using the BBI.

150921

28.

Alteon discarded ACK packets sent by client in response to server TCP keep-alive packets.

150750

29.

The XML configuration API could not be used to change a vADC configuration.

150484

30.

The message sent when Alteon was shut down due to critical temperature was not accurate.

150456

31.

Importing a certificate in PKCS12 format to a vADC failed with the error "Error: Failed to extract cert+key".

150376

32.

When user "user” was disabled for a vADC, it could still be used to access the vADC.

150327

33.

Fragmented traffic that arrived for a virtual service which was processed by the Acceleration Engine caused a device panic.

150326

34.

When an Intermediate CA Certificate Group and Intermediate CA Certificate had the same name, and the group was attached to an SSL policy, Alteon sent an Intermediate CA Certificate instead.

150306

35.

When querying the VRRP status using SNMP in the Global Admin context of an ADC-VX device, the state of the Virtual Routers was incorrectly reported.

149938

36.

Occasionally when Alteon did not forward an RST from the client to the server, the client received packets with the real server IP as the source instead of the VIP.

149875

37.

Using the BBI, the user was able to configure a different application type for a standard service port when using IE6. After device/vADC restart, the configuration of such services was erased.

149702

38.

The /info/slb/gslb/geo command did not display anything.

149636

39.

When the HTTP method was split across packets,

149554

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 47

Fixed in version 28.1.5.0 Item

Description

Bug ID

Alteon dropped the first packet which contained an invalid method and sent an HTTP_501 error message to the client. 40.

There was an inconsistency between the actual altSwBulkApply trap packet and the description in MIB file.

149539

41.

Bandwidth Management did not work on IPv6 traffic in Alteon version 28.1.

149497

42.

Alteon allowed using the same IP address for a vADC peer address and a Global Admin management address.

148866

43.

A group could not be deleted from CLI; the following error message displayed during the apply phase: "Unable to lock cli, no response from configuration thread!" The group still appeared in the configuration dump, but it was empty.

148726

44.

On sessions for which delayed binding was performed, if a FIN packet arrived from the client immediately after HTTP request packet the switch dropped the FIN packet.

148673

45.

When user authentication was performed using RADIUS, if the RADIUS servers were unavailable and the user existed in the local user data base and had backdoor enabled, Alteon asked for user/password credentials again, instead of using the credentials provided the first time.

148671

46.

When persistency using cookie insert was configured, the age of the actual session entry was updated to 4 minutes instead of using the selected real server timeout value.

148661

47.

When Alteon performed delayed binding, if, in addition to persistency, content hash based load-balancing (such as URL hash or WTS user hash) was configured, TCP requests retransmissions were dropped.

148649

48.

When an NTP and a DNS service were configured for the same virtual server, an NTP request that arrived immediately after a DNS request was sent to the DNS server group instead of the NTP server group.

148640

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 48

Fixed in version 28.1.5.0 Item

Description

Bug ID

49.

The admin password could not be changed using a SSH connection.

148469

50.

Configuration synchronization failed after upgrade from 27.0.1.0 to 28.1. The remote peer reset the connection.

148214

51.

When DSR VIP health checking was enabled and the health check was UDP, the health check was sent to the real server IP instead of the VIP.

148213

52.

SP memory utilization could not be monitored through SNMP.

147657

53.

The persistency entry age update behavior when modifying Real Server Inactivity Timeout (/cfg/slb/real x/tmout) and when changing Virtual Service Persistency Timeout (/cfg/slb/virt x/service x/tmout) was inconsistent.

147523

54.

The switch gateway was temporarily down when adding a local static route.

143262

Fixed in version 28.1.2 Item

Description

Bug ID

1.

When using the /maint/tsdmp command, the device failed.

147546

2.

When the route from the client to a VIP had an MTU less than 1460, the router sent an ICMP error that forced Alteon to split packets into smaller segments. On Alteon, this client IP’s repository was limited to 10, so the 11th client still received high MTU traffic, resulting in no traffic being forwarded from the router to this client.

148516

3.

When a POST request was sent, it could be divided into a header section and data section.

147992

When the header section reached the server, the server could send 200 OKs before receiving the data section. When this happened, the next HTTP request was not forwarded to the server and the connection was not terminated. 4.

On a 5412 platform, boot-up time took more than 5

114954

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 49

Fixed in version 28.1.2 Item

Description

Bug ID

minutes. 5.

Using BBI, when deleting an object attached to a virtual 121073 service (such as a caching policy, compression policy, or an HTTP modifications rule list), you had to remove it from the virtual service in order for the Apply to succeed. However, after it was deleted, the object did not appear as selected in the virtual service, which may have been misleading.

6.

There was no SNMP configuration (MIB) support for new features added in version 27.0.0.0, including caching, compression, HTTP modifications, and HTTP connection management.

121097

SNMP (MIB) support for status and monitoring is now fully available. 7.

An HTTPS certificate change did not take effect until the HTTPS service was restarted (disabled and then enabled).

146716

8.

When Alteon was configured with VRRP and a high volume of SSL traffic was sent for a long period, a failure could have occurred.

146876

9.

The device sometimes stopped advertising OSPF routes due to timer issue.

285641

10.

On sessions for which delayed binding was performed; if a FIN packet arrived from the client immediately after HTTP request packet the switch dropped the FIN packet.

148673

11.

vADC statistics limit command showed incorrect values for SSL CPS and device throughput

147825

12.

BPDU frame with MAC address 00:00:00:00:00:00 were forwarded by Alteon

147168

Known Limitations This section lists all known limitations for this release.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 50

Limitations in version 28.1.10.0 Item

Description

1.

In Alteon VA, as all its ports are in the same VLAN by default, its ports can be interconnected to the same broadcast domain causing a network loop. Workaround: define port 2 in VLAN 2 as port 1 is defined in VLAN1

Bug ID

170110

(Fixed in 29.0) 2.

When x-forward-for was enabled on a service with 173659 least connection rmetric, its starts corrupting PIP address when sending traffic to backend. (fixed in 29.0)

3.

Sometimes, software image download process failed. In most of the times, download retry was successful

4.

When "httpslb or urlslb" is configured, in a group with least connection matric. The string match is checked in both httpslb and urlslb although the precedence is set to OR and not AND.

167409 170004

(fixed in 29.0) 5.

Alteon only supports IPv4 as agent address in the SNMP trap

166454

6.

The put image option /boot/ptimg is not supported

110769

7.

The configuration dump done from BBI does not use Courier-New font. For this reason, the PKI components included in the dump looks like they are not formatted correctly.

110848

8.

When using HTTP connection management (HTTP Multiplexing) and group server maximum connections (maxconn) is reached, the persistent connections opened for multiplexing are also not reused to server client requests.

110952

9.

Capture and decrypt capture functionality is supported only using the CLI. BBI does not support this functionality.

111085

10.

Importing the 2424- SSL processor configuration file to migrate its certificate repository to version 27.x is supported only using the CLI.

111453

11.

BGP does not remove from its table a route that was learned from RIP, even though the route had been withdrawn. When redistribution of RIP routes to BGP is configured, and a route that is learned from RIP has

112196

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 51

Limitations in version 28.1.10.0 Item

Description

Bug ID

failed, BGP should send an UPDATE message containing the withdrawn route to its peers and state that it is not removing the route entry from the routing and BGP tables. 12.

The /stats/mp/cpu option shows the MP CPU utilization for one second, the average for four seconds, and the average for 64 seconds. It takes up to 25 seconds for the four-second average to get updated properly and almost 5 minutes for the 64-second average to get updated properly.

114941

13.

The scheduled reboot option /boot/sched is not supported.

114952

14.

BWM statistics are different when used with different contracts within the same policy. When the user assigns different contracts for different ports with equal capacity within the same policy, statistics of both ports differ even though the same policy is applied. This means that the number of total packets and discarded packets varied for two different ports.

114967

15.

A new image is downloaded to the image2 slot even though the instruction was to download to the image1 slot. The new image is downloaded to image 1, but after being written to the CompactFlash, the images are then swapped.

114968

16.

The upgrade process does not ask the user to confirm the upgrade after the new image is downloaded.

114987

17.

The upgrade process cannot be aborted when the wrong password is provided. Currently, there is no way to abort the upgrade process other than waiting for the idle time out (5 minutes) to expire.

114988

18.

The GSLB, command /info/slb/gslb/geo (geographical preference information) does not display the region list.

115002

19.

If an image is downloaded to an active bank, the warning is displayed only after the download is finished and file writing is aborted.

115009

20.

On a 4416 platform, there is a bottleneck on throughput 115834 when DAM enabled (only 3G can be reached).

21.

On a 5412 platform, the link status displays incorrectly

115899

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 52

Limitations in version 28.1.10.0 Item

Description

Bug ID

when changing some port parameters. 22.

The number of free pports reflected by the commands /stats/slb/pip and /stats/slb/sp x/pip is calculated for a single real server, where it should be multiplied by number of real servers.

116638

23.

Alteon HTTP cache does not respect the range HTTP header to request only part of an object.

119892

24.

Using HTTP modifications with the file type element, only the replace action is supported. If removing or inserting a file type (file extension) is required, use the modification of element of type URL.

119911

25.

When a client port is part of multiple VLAN, and multiplexing is used, the VLAN used in the back-end connection (to the server) is always the one used to initiate the connection.

121126

This problem does not exist when proxy IP (PIP) is done on the egress port, as recommended in Radware’s best practices for connection management (multiplexing). 26.

With large configurations, the Revert-Apply operation may fail with multiple errors generated that are related to a legitimate CLI command that did not succeed.

121285

Workaround: Run the Revert-Apply operation again. 27.

Proxy IP (PIP) statistics are available only when multiplexing is enabled on the virtual service.

121299

28.

Jumbo frames are not supported in this release.

121765

29.

Fragmented traffic is not supported when accessing the device management.

134531

30.

Alteon legacy content-based switching with delayed binding enabled does not work with fragmented traffic.

139880

Work around: Use pbind force-proxy mode 31.

When more than 390 certificates and keys of different types are configured, accessing the BBI certificate repository page might cause the device failure.

142396

32.

Overlapping NAT capability is not supported for IPv6 filters.

143690

33.

After downgrading from 28.1.x.0 to 26.3.x, the user is

146536

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 53

Limitations in version 28.1.10.0 Item

Description

Bug ID

prompted to keep or discard the management IP. Even if the user answers No, the management IP is saved. 34.

IPv6 traffic destined to directly connected network is forwarded to the gateway instead of the configured IPv6 interfaces.

152729

Workaround: Define the local route cache for the immediately connected network using /cfg/l3/frwd/local/add6 command. 35.

Passive FTP doesn't work over IPv6

155745

(fixed in 29.0) 36.

Highly fragmented connections that include more than 20,000 fragments drop fragments.

121288

37.

On Alteon 4408, the power LED does not turn red when there is a power supply failure.

N/A

38.

Live capture (TCPdump) mode is not supported via a serial console.

N/A

39.

When downloading an image, you cannot have the same image version in both image banks (image1 and image2). When downloading the same version, the older image is overwritten by the newly downloaded image.

N/A

ADC-VX / vADC Specific Limitations 40.

MP Virtualization (vMP) goes to 100% utilization VRRP when using VLAN tag and shared VLAN for ISL. When this occurs, both vADCs in the HA pair become the master with or without traffic for a short while.

131075

41.

When the device is working in ADC-VX mode, uploading the global configuration (gtcfg by global administrator) does not replace existing vADCs with the ones in the new configuration. Instead, it merges them. If the uploaded file includes vADC IDs that are already on the device, the user is prompted to overwrite the existing vADC configuration with the imported one.

143192

Workaround: Manually delete all vADCs before importing a new configuration. 42.

When using a script to configure several vADCs in parallel, the server certificate Generate command

144673

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 54

Limitations in version 28.1.10.0 Item

Description

Bug ID

might stop working until reboot is performed. 43.

When a vADC is rebooted, it shows an incorrect alert message saying a throughput limit of 0 has been reached.

144918

This message should be ignored. 44.

An incorrect VLAN ID appears in a warning message when HAID 0 is used for two vADCs on the same shared VLAN.

145673

45.

In case Global Admin context process restarts, the user is not able to perform Revert Apply to the last configuration.

146405

46.

When synchronizing the configuration between a vADC instance running on a 5224 device and a standalone 5412 device that uses different physical ports, a "bad port" error is received, even after disabling ID ports synchronization using /cfg/slb/sync/ports.

146570

Related Documentation The following documentation is related to this version:      

Alteon Application Switch Operating System Application Guide version 28.1.11.0 Alteon Application Switch Operating System Command Reference version 28.1.11.0 Alteon Application Switch Operating System Browser-Based Interface Quick Guide version 28.1.11.0 Alteon Application Switch Operating System Troubleshooting Guide version 28.1.11.0 Browser-Based Interface (BBI) Quick Guide version 28.1.11.0 Alteon Application Switch Performance Report version 28.1.0.0

For the latest Radware product documentation, refer to the product CD/DVD that was shipped with your product, or download it from http://www.radware.com/Customer/Portal/default.asp.

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 55

North America

International

Radware Inc.

Radware Ltd.

575 Corporate Drive

22 Raoul Wallenberg St.

Mahwah, NJ 07430

Tel Aviv 69710, Israel

Tel: +1-888-234-5763

Tel: 972 3 766 8666

© 2013 Radware, Ltd. All Rights Reserved. Radware and all other Radware product and service names are registered trademarks of Radware in the U.S. and other countries. All other trademarks and names are the property of their respective owners. Printed in the U.S.A

Title: Alteon Application Switch version 28.1.11.0 Release Notes, August 01, 2013 Page 56

View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF