MOCN :Co-AAU Co-Baseband Board Co-MPT Co-EMS BBU configuration rules: 1、MOCN shares the one cell, one cell must be configured in ONE Baseband board. 2、For ONE hardware( AAU/RRU),it can only managed by ONE EMS. 3、If ONE RF hardware (AAU/RRU) is connected to different BBUs, inter-BBU Interconnection is needed(CI interface) to keep sync. and control between BBUs. GU 900M
UL 2100M
BBU3900 GU(A+B) WBBPd2 WBBPb3
GTMU UMPTa1
BBU3900 LO(A+B)
GU 900M
UL2100M
BBU3900 GU(A+B) NR is introduced CI interconnection
WBBPd2 WBBPb3
GTMU UMPTa1
BBU5900 LN(A+B) CI
interconnection
UBBPd6 UBBPd6
UBBPd6 UBBPd6
L 1800M
UBBPg3
UMPTa2/b/e
L 800M
UMPTe (A/B)
L 1800M
L 800M
NR 3500M(A+B)
MORAN1:Co-AAU Co-EMS Separated-Baseband board BBU configuration rules: 1、PLMN_A and PLMN_B have different cells, Same RAT cells must be configured in ONE Control board; Different RAT Cell can have different Control board or same one. 2、For ONE hardware( AAU /RRU),it can only managed by ONE EMS. 3、If ONE RF hardware (AAU/RRU) is connected to different BBUs, inter-BBU Interconnection is needed(CI interface) to keep sync. and control between BBUs. 4 、Different cells can be configured on different BBP, Co-BBP or separated BBP are both available. GU 900M
UL 2100M
BBU3900 GU(A+B WBBPd2 WBBPb3
GTMU UMPTa1
BBU3900 LO A+B
GU 900M
UL2100M
BBU3900 GU(A+B) NR is introduced CI interconnection
WBBPd2 WBBPb3
GTMU UMPTa1
BBU5900 LN(A+B) CI
interconnection
UBBPd6 UBBPd6
UBBPd6 UBBPd6
UBBPg3(A)
UMPTa2/b/e
UBBPg3(B) UMPTe (A/B) When A+B bandwidth >100MHz, two fibers are needed
L 1800M
L 800M
L 1800M
L 800M
NR 3500M(A+B)
MORAN2 : Co-AAU Co-EMS Co-Baseband Board BBU configuration rules: 1、PLMN_A and PLMN_B have different cells, Same RAT cells must be configured in ONE Control board;Different RAT Cells can have different Control board or same one. 2、For ONE hardware( AAU /RRU),it can only managed by ONE EMS. 3、If ONE RF hardware (AAU/RRU) is connected to different BBUs, inter-BBU Interconnection is needed(CI interface) to keep sync. and control between BBUs. 4 、Different cells can be configured on different BBP, Co-BBP or separated BBP are both available. GU 900M
UL 2100M
BBU3900 GU(A+B) WBBPd2 WBBPb3
GTMU UMPTa1
BBU3900 LO(A+B)
GU 900M
UL2100M
BBU3900 GU(A+B) NR is introduced
WBBPd2 WBBPb3
CI interconnection
GTMU UMPTa1
BBU5900 LN(A+B) CI
interconnection
UBBPd6 UBBPd6
UBBPd6 UBBPd6
UBBPg3(A)
UMPTa2/b/e
UMPTe (A/B) When A+B bandwidth >100MHz, two fibers are needed
L 1800M
L 800M
L 1800M
L 800M
NR 3500M(A+B)
MOCN vs MORAN(two solutions) Configuration Summary MOCN
Thank you for interesting in our services. We are a non-profit group that run this website to share documents. We need your help to maintenance this website.