400 KV-Interlock Logic Diagram_RevB
October 13, 2017 | Author: lovy85 | Category: N/A
Short Description
Download 400 KV-Interlock Logic Diagram_RevB...
Description
Name
Name
Date
Date
Date
Name
Name
Name
Date
Date
Date
Name
Name
A
FIRST ISSUE
REV.
Date DINESH
Name
MHB
Name
RJR
Date
06/08/2008
Date
06/08/2008
Date
06/08/2008
Name
RSD
Name
MHB
Name
RJR
Date
06/12/2006
Date
06/12/2006
Date
13/6/2006
DESCRIPTION
DRAWN
CLIENT :
Date
Name
CHECKED
SIGN.
UPDATED BASED UPON CUSTOMER'S COMMENTS
FA FC SIGN.
Date B
Name
Name
SIGN.
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
DF001
APPROVED
STATUS
ADANI POWER LIMITED 2 x 330MW THERMAL POWER PLANT MUNDRA SEZ, TUNDA, SIRACHA VILLAGE, KUTCHH DIST. GUJARAT
CONTRACT No.: PROJECT :
APL / 130001 / VJ / 967 / 07 DATED 21.11.2007
400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ FICHTNER
CONSULTANT
CONSULTING ENGINEERS (INDIA) PRIVATE LIMITED, CHENNAI
File: PG725000-
TITLE :
400 KV CONTROL & INTERLOCK LOGIC DIAGRAM AREVA T&D India Limited A-7, SECTOR-65 NOIDA - 201301
DRAWING NO.
REV.
EMI-7604PG754-4-028
B
SHEET TOTAL SHEET
001
92
DF002
REVISION
SHEET
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
A B C D E F G H
DESCRIPTION
REVISION
SHEET
I
A B C D E F G H
DESCRIPTION I
001
X X
FRONT SHEET
042
X X
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN ICT-1
002
X X
INDEX
043
X X
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN ICT-1
003
X
CONTROL LOGIC FOR LOCAL OPERATION OF ISOLATORS FROM EQP M.BOX
044
X X
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN ICT-1
004
X
CONTROL LOGIC FOR REMOTE OPERATION OF ISOLATORS FROM BCU
045
X X
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN ICT-1
005
X
CONTROL LOGIC FOR REMOTE OPERATION OF ISOLATORS FROM HMI
046
X X
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-3
006
X
CONTROL LOGIC FOR REMOTE OPERATION OF ISOLATORS FROM SCADA
047
X X
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-3 (CONTD.)
007
X
CONTROL LOGIC FOR LOCAL OPERATION OF CKT. BKRS FROM EQP M. BOX
048
X X
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN O/G LINE-3
008
X
CONTROL LOGIC FOR REMOTE OPENING OF CIRCUIT BREAKERS FROM BCU/BAY CONTROL & PROTECTION PANEL *
049
X X
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN O/G LINE-3
008A
X
PROTECTION TRIP LOGIC FOR LINE PROTECTIONS(TYPICAL)
050
X X
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN O/G LINE-3
008B
X
PROTECTION TRIP LOGIC FOR TIE PROTECTIONS(TYPICAL)
051
X X
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN O/G LINE-3
008C
X
PROTECTION TRIP LOGIC FOR GT PROTECTIONS(TYPICAL)
052
X X
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN TIE-3
008D
X
PROTECTION TRIP LOGIC FOR ICT PROTECTIONS(TYPICAL)
053
X X
CONTROL & INTERLOCK LOGIC FOR OPERATION OFEARTH SWITCHES IN TIE-3
009
X X
CONTROL LOGIC FOR REMOTE CLOSING OF CIRCUIT BREAKERS FROM BCU/ BAY CONTROL & PROTECTION PANEL *
054
X X
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN TIE-3
010
X
CONTROL LOGIC FOR REMOTE OPENING OF CIRCUIT BREAKERS FROM HMI *
055
X X
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN TIE-3
011
X X
CONTROL LOGIC FOR REMOTE CLOSING OF CIRCUIT BREAKERS FROM HMI *
056
X X
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN TIE-3
012
X
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN O/G LINE 1
057
X X
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN ICT-2
013
X X
058
X X
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN ICT-2 (CONTD.)
014
X X
059
X X
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN ICT-2
015
X X
INTERLOCK LOGIC FOR OPERATION OF ISOLATORS IN O/G LINE-1
060
X X
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN ICT-2
016
X X
INTERLOCK LOGIC FOR OPERATION OF ISOLATORS IN O/G LINE-1 (CONTD)
061
X X
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN ICT-2
017
X X
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN O/G LINE 1
062
X X
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN O/G ICT-2
018
X X
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN O/G LINE-1
063
X X
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-4
019
X X
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN O/G LINE-1
064
X X
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-4 (CONTD.)
020
X X
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN TIE-1
065
X X
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN O/G LINE-4
021
X X
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN TIE-1
066
X X
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN O/G LINE-4
022
X X
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN TIE-1
067
X X
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN O/G LINE-4
023
X X
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN TIE-1
068
X X
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN O/G LINE-4
023A
X X
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN TIE-1 (CONTD.)
069
X X
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN TIE-4
024
X X
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN TIE-1
070
X X
CONTROL & INTERLOCK LOGIC FOR OPERATION OFEARTH SWITCHES IN TIE-4
025
X X
INTERLOCK LOGIC FOR OPERATION OF ISOLATORS IN GT-3
071
X X
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN TIE-4
026
X X
INTERLOCK LOGIC FOR OPERATION OF ISOLATORS IN GT-3 (CONTD.)
072
X X
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN TIE-4
027
X X
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN GT-3
073
X X
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN TIE-4
028
X X
CONTROL & INTERLOCK LOGIC FOR OPENING & CLOSING OF CIRCUIT BREAKER IN GT-3
074
X
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN TIE-4
029
X X
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-2
075
X X
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN GT-4
030
X X
INTERLOCK LOGIC FOR OPERATION OF ISOLATORS IN O/G LINE-2 (CONTD.)
076
X X
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN GT-4 (CONTD.)
031
X X
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN O/G LINE 2
077
X X
CONTROL & INTERLOCK LOGIC FOR OPENING & CLOSING OF CIRCUIT BREAKER IN GT-4
032
X X
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN O/G LINE-2
078
X X
CONTROL & INTERLOCK LOGIC FOR OPENING & CLOSING OF CIRCUIT BREAKER IN GT-4
033
X X
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN O/G LINE-2
079
X X
INTERLOCK LOGIC FOR OPERATION OF BUS-1 CVT ISOLATOR & EARTH SWITCH
034
X X
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN O/G LINE-2
080
X X
INTERLOCK LOGIC FOR OPERATION OF BUS-2 CVT ISOLATOR & EARTH SWITCH
035
X X
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN TIE-2
081
X
IMPLEMENTATION OF SYNCHROCHECK IN BCU
036
X X
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN TIE-2
082
X
IMPLEMENTATION OF SYNCHROCHECK IN BCU
037
X X
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN TIE-2
083
X
IMPLEMENTATION OF SYNCHROCHECK IN BCU
038
X X
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN TIE-2
084
X
IMPLEMENTATION OF SYNCHROCHECK IN BCU
039
X X
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN TIE-2
085
X
IMPLEMENTATION OF AUTORECLOSE FUNCTION IN BCU
040
X X
INTERLOCK LOGIC FOR OPERATION OF400kV ISOLATORS IN ICT-1
086
X
IMPLEMENTATION OF AUTORECLOSE FUNCTION IN BCU
041
X X
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN ICT-1 (CONTD.)
CONTROL LOGIC FOR REMOTE OPENING OF CIRCUIT BREAKERS FROM SCADA (LDC) * CONTROL LOGIC FOR REMOTE CLOSING OF CIRCUIT BREAKERS FROM SCADA (LDC) *
File: PG725000-002.xls
CLIENT PROJECT
: :
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA INDEX
REV.
SHEET
NEXT SH.
B
002
003
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL LOGIC FOR LOCAL OPERATION OF ISOLATORS FROM EQUIPMENT MARSHALLING BOX*
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
EQP LOCAL/REMOTE LOCAL = EQP M.BOX SELECTOR SWITCH AT EQP REMOTE = BCU/HMI/SCADA MARSHALLING BOX
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
INTLK PERMISSIVE FROM RESPECTIVE BCU **
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
INTLK PERMISSIVE FROM RESPECTIVE BCU **
NOTE : *
IN THIS MODE, CONTROL FROM HIGHER LEVELS NAMELY BCU / HMI/ SCADA ARE DEFEATED AS LONG AS THE LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX IS IN LOCAL MODE.
**
INTERLOCKS REQUIRED FOR CLOSING/OPENING OF ISOLATORS ARE VERIFIED IN THE RESPECTIVE BAY CONTROL UNIT AND A OUTPUT IS GENERATED FROM THE BCU WHEN THE INTERLOCKS ARE SATISIFIED. THE GENERATED OUTPUT IS HARDWIRED IN THE CONTROL CIRCUIT OF THE ISOLATOR. OPEN/CLOSE COMMANDS TO THE ISOLATOR ARE NOT EXECUTED UNLESS THE INTERLOCKS ARE SATISFIED. OPERATION OF THE ISOLATORS EITHER FROM LOCAL/REMOTE WILL BE SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH. INTERLOCKS CAN BE BYPASSED UNDER EMERGENCY CONDITIONS, BY AUTHORISED PERSONNEL ONLY.
***
FOR DETAILED INTERLOCKS REFER THE INTERLOCKS FOR THE RESPECTIVE DETAILED INTERLOCKS.
File: PG725000-003.xls
CLIENT PROJECT
CONTROL LOGIC FOR LOCAL OPERATION OF 400kV ISOLATORS
: :
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
A
003
004
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL LOGIC FOR REMOTE OPERATION OF ISOLATORS FROM BCU*
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
EQP LOCAL/REMOTE LOCAL = EQP M.BOX SELECTOR SWITCH AT EQP MARSHALLING BOX REMOTE = BCU/HMI/SCADA
BAY LOCAL/REMOTE PUSH BUTTON ON BCU
OPEN/CLOSE PUSH BUTTON CONTROL FROM BCU
INTLK PERMISSIVE FROM RESPECTIVE BCU **
LOCAL = BCU
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
REMOTE = HMI / SCADA
OPEN CLOSE
INTLK PERMISSIVE FROM RESPECTIVE BCU **
NOTE : *
IN THIS MODE, CONTROL FROM HIGHER LEVELS NAMELY HMI/ SCADA ARE DEFEATED AS LONG AS THE LOCAL/REMOTE SELECTOR SWITCH AT BCU IS IN LOCAL MODE.
**
INTERLOCKS REQUIRED FOR CLOSING/OPENING OF ISOLATORS ARE VERIFIED IN THE RESPECTIVE BAY CONTROL UNIT AND A OUTPUT IS GENERATED FROM THE BCU WHEN THE INTERLOCKS ARE SATISIFIED. THE GENERATED OUTPUT IS HARDWIRED IN THE CONTROL CIRCUIT OF THE ISOLATOR. OPEN/CLOSE COMMANDS TO THE ISOLATOR ARE NOT EXECUTED UNLESS THE INTERLOCKS ARE SATISFIED. OPERATION OF THE ISOLATORS EITHER FROM LOCAL/REMOTE WILL BE SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH. INTERLOCKS CAN BE BYPASSED UNDER EMERGENCY CONDITIONS, BY AUTHORISED PERSONNEL ONLY.
***
FOR DETAILED INTERLOCKS REFER THE INTERLOCKS FOR THE RESPECTIVE DETAILED INTERLOCKS.
File: PG725000-003.xls
CLIENT PROJECT
CONTROL LOGIC FOR REMOTE OPERATION OF 400kV ISOLATORS FROM BCU
: :
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
A
004
005
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL LOGIC FOR REMOTE OPERATION OF ISOLATORS FROM HMI*
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
LOCAL = EQP M.BOX EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP REMOTE = BCU/HMI/SCADA MARSHALLING BOX
BAY LOCAL/REMOTE PUSH BUTTON ON BAY CONTROL UNIT
REMOTE = HMI / SCADA
SUBTATION LOCAL/REMOTE SELECTION FROM HMI
REMOTE = SCADA
OPEN/CLOSE CONTROL FROM HMI
INTLK PERMISSIVE FROM RESPECTIVE BCU **
LOCAL = BCU
TO OPEN CIRCUIT
&
LOCAL = HMI
OPEN CLOSE INTLK PERMISSIVE FROM RESPECTIVE BCU **
TO CLOSING CIRCUIT
&
NOTE : *
IN THIS MODE, CONTROL FROM HIGHER SCADA LEVEL ARE DEFEATED AS LONG AS THE LOCAL/REMOTE SELECTION AT HMI IS IN LOCAL MODE.
**
INTERLOCKS REQUIRED FOR CLOSING/OPENING OF ISOLATORS ARE VERIFIED IN THE RESPECTIVE BAY CONTROL UNIT AND A OUTPUT IS GENERATED FROM THE BCU WHEN THE INTERLOCKS ARE SATISIFIED. THE GENERATED OUTPUT IS HARDWIRED IN THE CONTROL CIRCUIT OF THE ISOLATOR. OPEN/CLOSE COMMANDS TO THE ISOLATOR ARE NOT EXECUTED UNLESS THE INTERLOCKS ARE SATISFIED. OPERATION OF THE ISOLATORS EITHER FROM LOCAL/REMOTE WILL BE SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH. INTERLOCKS CAN BE BYPASSED UNDER EMERGENCY CONDITIONS, BY AUTHORISED PERSONNEL ONLY.
***
FOR DETAILED INTERLOCKS REFER THE INTERLOCKS FOR THE RESPECTIVE DETAILED INTERLOCKS.
File: PG725000-003.xls
CLIENT PROJECT
CONTROL LOGIC FOR REMOTE OPERATION OF 400kV ISOLATORS FROM HMI
: :
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
A
005
006
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL LOGIC FOR REMOTE OPERATION OF ISOLATORS FROM SCADA(LDC)
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
EQP LOCAL/REMOTE LOCAL = EQP M.BOX SELECTOR SWITCH AT EQP MARSHALLING BOX REMOTE = BCU/HMI/SCADA
BAY LOCAL/REMOTE PUSH BUTTON ON BAY CONTROL UNIT
REMOTE = HMI / SCADA
SUBTATION LOCAL/REMOTE SELECTION FROM HMI
REMOTE = SCADA
OPEN/CLOSE CONTROL FROM HMI
INTLK PERMISSIVE FROM RESPECTIVE BCU **
LOCAL = BCU
TO OPEN CIRCUIT
&
LOCAL = HMI
OPEN CLOSE INTLK PERMISSIVE FROM RESPECTIVE BCU **
&
TO CLOSING CIRCUIT
**
INTERLOCKS REQUIRED FOR CLOSING/OPENING OF ISOLATORS ARE VERIFIED IN THE RESPECTIVE BAY CONTROL UNIT AND A OUTPUT IS GENERATED FROM THE BCU WHEN THE INTERLOCKS ARE SATISIFIED. THE GENERATED OUTPUT IS HARDWIRED IN THE CONTROL CIRCUIT OF THE ISOLATOR. OPEN/CLOSE COMMANDS TO THE ISOLATOR ARE NOT EXECUTED UNLESS THE INTERLOCKS ARE SATISFIED. OPERATION OF THE ISOLATORS EITHER FROM LOCAL/REMOTE WILL BE SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH. INTERLOCKS CAN BE BYPASSED UNDER EMERGENCY CONDITIONS, BY AUTHORISED PERSONNEL ONLY.
***
FOR DETAILED INTERLOCKS REFER THE INTERLOCKS FOR THE RESPECTIVE DETAILED INTERLOCKS.
File: PG725000-003.xls
CLIENT PROJECT
CONTROL LOGIC FOR REMOTE OPERATION OF 400kV ISOLATORS FROM SCADA
: :
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
A
006
007
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL LOGIC FOR LOCAL OPERATION OF CIRCUIT BREAKERS FROM EQUIPMENT MARSHALLING BOX*
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
LOCAL = EQP M.BOX EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP REMOTE = BCU/HMI/SCADA MARSHALLING BOX
&
TO TRIP COIL - 1
TO TRIP COIL - 2 OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
OPEN CLOSE
&
TO CLOSING CIRCUIT
HARDWIRED INTERLOCKS AT BMK LEVEL **
NOTE : *
IN THIS MODE, CONTROL FROM HIGHER LEVELS NAMELY BCU / HMI/ SCADA ARE DEFEATED AS LONG AS THE LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX IS IN LOCAL MODE.
**
THESE INTERLOCKS ARE HARDWIRED AT BMK LEVEL AND OPERATION FROM EQP. MARSHALLING BOX IS POSSIBLE ONLY WHEN THESE INTERLOCKS ARE SATISFIED. FOR DETAILS REFER THE RESPECTIVE BREAKER INTERLOCK LOGICS
File: PG725000-003.xls
CLIENT PROJECT
CONTROL LOGIC FOR LOCAL OPERATION OF 400kV CIRCUIT BREAKERS
: :
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
A
007
008
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL LOGIC FOR REMOTE OPENING OF CIRCUIT BREAKERS FROM BCU/BAY CONTROL & PROTECTION PANEL * LOCAL = EQP M.BOX EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP REMOTE = BCU/HMI/SCADA MARSHALLING BOX TO TRIP COIL - 1
OR
&
TO TRIP COIL - 2 This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
BAY LOCAL/REMOTE PUSH BUTTON ON BAY CONTROL UNIT
LOCAL = BCU REMOTE = HMI / SCADA
& OPEN/CLOSE PUSH BUTTON CONTROL FROM BCU
OPEN CLOSE
&
CNTL SWTCH FROM C&R PANEL FOR EMERGENCY CONTROL **
OPEN CLOSE
NOTE : *
IN THIS MODE, CONTROL FROM HIGHER LEVELS NAMELY HMI/ SCADA ARE DEFEATED AS LONG AS THE LOCAL/REMOTE SELECTOR SWITCH AT BCU IS IN LOCAL MODE.
**
EMERGENCY TRIPPING CAN BE GIVEN THROUGH THE TNC SWITCH PROVIDED ON THE BAY PROTECTION & CONTROL PANEL. CONTROLS GIVEN THROUGH TNC SWITCH ARE ROUTED INDEPENDENT OF THE BCU AND HENCE ARE INDEPENDENT OF THE LOCAL/REMOTE SELECTION AT BCU/HMI.
***
PERMISSIVE FOR MAINTENANCE CLOSING IS GENERATED FROM BCU, WHEN BOTH THE ISOLATORS ON EITHER SIDES OF THE CB ARE OPEN. THIS OUTPUT CONTACT FROM BCU IS WIRED INTO THE TNC CLOSING CIRCUIT. CLIENT PROJECT
CONTROL LOGIC FOR REMOTE OPENING OF 400kV LINE-TIE- ICT CIRCUIT BREAKERS FROM BCU
: :
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
A
008
008A
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
PROTECTION TRIP LOGIC FOR LINE PROTECTIONS(TYPICAL)
CLIENT PROJECT
PROTECTION TRIP LOGIC FOR LINE PROTECTION
: :
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
008A
009
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
PROTECTION TRIP LOGIC FOR TIE PROTECTIONS(TYPICAL)
CLIENT PROJECT
PROTECTION TRIP LOGIC FOR TIE PROTECTION
: :
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
008B
008C
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
PROTECTION TRIP LOGIC FOR GT PROTECTIONS(TYPICAL)
NOTE : *
ONLY HV O/C & E/F PROTECTION, LBB & BUSBAR PROTECTION ARE LOCATED IN THE SWITCHYARD RELAY PANEL. ALL THE OTHER PROTECTIONS ARE NOT IN PRESENT SCOPE.
CLIENT PROJECT
PROTECTION TRIP LOGIC FOR GT PROTECTION
: :
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
008C
008D
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
PROTECTION TRIP LOGIC FOR ICT PROTECTIONS(TYPICAL)
NOTE : *
220kV PROTECTIONS ARE NOT IN PRESENT SCOPE.
CLIENT PROJECT
PROTECTION TRIP LOGIC FOR ICT PROTECTION
: :
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
008D
009
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL LOGIC FOR REMOTE CLOSING OF CIRCUIT BREAKERS FROM BCU/ BAY CONTROL & PROTECTION PANEL * EQP LOCAL/REMOTE LOCAL = EQP M.BOX SELECTOR SWITCH AT EQP MARSHALLING BOX REMOTE = BCU/HMI/SCADA
SELECTED INCOMING VOLTS
SELECTED RUNNING VOLTS
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
& BAY LOCAL/REMOTE PUSH BUTTON ON BAY CONTROL UNIT
OPEN/CLOSE PUSH BUTTON CONTROL FROM BCU
LOCAL = BCU REMOTE = HMI / SCADA
VALIDATION OF CHECK-SYNC CONDITIONS IN BCU**
&
OPEN CLOSE
OR TO CLOSING CIRCUIT
INTLKS IMPLEMENTED THROUGH SOFT LOGIC IN RESPECTIVE BCU ***
CNTL SWTCH FROM C&R PANEL FOR EMERGENCY CONTROL
OPEN ## PERMISSIVE FOR TNC MAINTENANCE CLOSING FROM BCU (APPLIES TO ALL BAYS EXCEPT GT & GT TIE BAYS)
CLOSE
&
INTLKS IMPLEMENTED THROUGH HARDWIRING IN BAY CNTL & PROT PANEL***
ISO 89-A OPEN ##
&
PERMISSIVE
PERMISSIVE FOR MAINTENANCE CLOSING ISO 89-B OPEN NOTE : *
IN THIS MODE, CONTROL FROM HIGHER LEVELS NAMELY HMI/ SCADA ARE DEFEATED AS LONG AS THE LOCAL/REMOTE SELECTOR SWITCH AT BCU IS IN LOCAL MODE.
**
CHECK SYNCHRONISATION CONDITIONS ARE VALIDATED IN THE RESPECTIVE BAY CONTROL UNIT, BASED UPON THE SELECTED INCOMING & RUNNING VOLTAGES.
***
FOR DETAILED INTERLOCKING LOGICS REFER THE INTERLOCKS OF THE RESPECTIVE CIRCUIT BREAKER.
##
PERMISSIVE FOR MAINTENANCE CLOSING IS GENERATED FROM BCU, WHEN BOTH THE ISOLATORS ON EITHER SIDES OF THE CB ARE OPEN. THIS OUTPUT CONTACT FROM BCU IS WIRED INTO THE TNC CLOSING CIRCUIT.
1
CLOSE COMMAND GIVEN BY THE OPERATOR FROM BCU WILL BE EXECUTED ONLY IF THE CHECK-SYNC CONDITIONS ARE SATISFIED.
2
CLOSE COMMAND FROM TNC SWITCH IS MEANT FOR CLOSING WITHOUT ANY SYNCHRONISATION & HENCE TO BE USED FOR MAINTENANCE/TESTING CONDITIONS.
3
INCOMING & RUNNING VOLTS ARE SELECTED BASED UPON THE ISOLATOR & CB POSITIONS IN THE RESPECTIVE DIA.
4
FOR GT-3 & GT-4 (BAYS-3, 12) REMOTE OPERATION IS NOT PROVIDED FROM SWITCHYARD.
5
FOR TIE-1 & TIE-4 (BAYS-2, 11) REMOTE OPERATION IS POSSIBLE FROM BCU/HMI/SCADA ONLY AS LONG AS THE TIE/GT SELECTOR SWITCH IS IN TIE MODE.
CLIENT ADANI POWER LTD. : 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT PROJECT : MUNDRA SEZ
CONTROL LOGIC FOR REMOTE CLOSING OF 400kV LINE-TIE-ICT CIRCUIT BREAKERS FROM BCU
AREVA
REV.
SHEET
NEXT SH.
B
009
010
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL LOGIC FOR REMOTE OPENING OF CIRCUIT BREAKERS FROM HMI *
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
LOCAL = EQP M.BOX EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP REMOTE = BCU/HMI/SCADA MARSHALLING BOX
BAY LOCAL/REMOTE PUSH BUTTON ON BAY CONTROL UNIT
LOCAL = BCU REMOTE = HMI / SCADA
& &
SUBTATION LOCAL/REMOTE SELECTION FROM HMI
LOCAL = HMI
TO TRIP COIL - 1
OR
REMOTE = SCADA
TRIP COIL - 2
OPEN/CLOSE CONTROL FROM HMI
CNTL SWTCH FROM C&R PANEL FOR EMERGENCY CONTROL **
OPEN
&
CLOSE
OPEN CLOSE
NOTE : *
IN THIS MODE, CONTROL FROM HIGHER LEVELS NAMELY HMI/ SCADA ARE DEFEATED AS LONG AS THE LOCAL/REMOTE SELECTOR SWITCH AT BCU IS IN LOCAL MODE.
**
EMERGENCY TRIPPING CAN BE GIVEN THROUGH THE TNC SWITCH PROVIDED ON THE BAY PROTECTION & CONTROL PANEL. CONTROLS GIVEN THROUGH TNC SWITCH ARE ROUTED INDEPENDENT OF THE BCU.
CLIENT PROJECT
CONTROL LOGIC FOR REMOTE OPENING OF 400kV LINE-TIE- ICT CIRCUIT BREAKERS FROM HMI
: :
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
A
010
011
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL LOGIC FOR REMOTE CLOSING OF CIRCUIT BREAKERS FROM HMI *
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
LOCAL = EQP M.BOX EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP REMOTE = BCU/HMI/SCADA MARSHALLING BOX
SELECTED INCOMING VOLTS
SELECTED RUNNING VOLTS
& BAY LOCAL/REMOTE PUSH BUTTON ON BAY CONTROL UNIT
SUBTATION LOCAL/REMOTE SELECTION FROM HMI
LOCAL = BCU REMOTE = HMI / SCADA
VALIDATION OF CHECK-SYNC CONDITIONS IN BCU**
&
LOCAL = HMI REMOTE = SCADA
OR OPEN/CLOSE CONTROL FROM HMI
TO CLOSING CIRCUIT
OPEN CLOSE
INTLKS IMPLEMENTED THROUGH SOFT LOGIC IN RESPECTIVE BCU ***
INTLKS IMPLEMENTED THROUGH HARDWIRING IN BAY CNTL & PROT PANEL*** CNTL SWTCH FROM C&R PANEL FOR EMERGENCY CONTROL
## PERMISSIVE FOR TNC MAINTENANCE CLOSING FROM BCU (APPLIES TO ALL BAYS EXCEPT GT & GT TIE BAYS)
&
OPEN
ISO 89-A OPEN CLOSE ##
&
PERMISSIVE
PERMISSIVE FOR MAINTENANCE CLOSING ISO 89-B OPEN
NOTE : *
IN THIS MODE, CONTROL FROM SCADA ARE DEFEATED AS LONG AS THE SUBSTATION LOCAL/REMOTE SELECTION IS IN LOCAL MODE.
**
CHECK SYNCHRONISATION CONDITIONS ARE VALIDATED IN THE RESPECTIVE BAY CONTROL UNIT, BASED UPON THE SELECTED INCOMING & RUNNING VOLTAGES.
***
FOR DETAILED INTERLOCKING LOGICS REFER THE INTERLOCKS OF THE RESPECTIVE CIRCUIT BREAKER.
##
PERMISSIVE FOR MAINTENANCE CLOSING IS GENERATED FROM BCU, WHEN BOTH THE ISOLATORS ON EITHER SIDES OF THE CB ARE OPEN. THIS OUTPUT CONTACT FROM BCU IS WIRED INTO THE TNC CLOSING CIRCUIT.
1
CLOSE COMMAND GIVEN BY THE OPERATOR FROM HMI WILL BE EXECUTED ONLY IF THE CHECK-SYNC CONDITIONS ARE SATISFIED.
2
CLOSE COMMAND FROM TNC SWITCH IS MEANT FOR CLOSING WITHOUT ANY SYNCHRONISATION & HENCE TO BE USED FOR MAINTENANCE/TESTING CONDITIONS.
3
INCOMING & RUNNING VOLTS ARE SELECTED BASED UPON THE ISOLATOR & CB POSITIONS IN THE RESPECTIVE DIA.
CONTROL LOGIC FOR REMOTE CLOSING OF 400kV LINE-TIE- ICT CIRCUIT BREAKERS FROM HMI
CLIENT ADANI POWER LTD. : 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT PROJECT : MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
011
012
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL LOGIC FOR REMOTE OPENING OF CIRCUIT BREAKERS FROM SCADA (LDC) *
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
EQP LOCAL/REMOTE LOCAL = EQP M.BOX SELECTOR SWITCH AT EQP MARSHALLING BOX REMOTE = BCU/HMI/SCADA
BAY LOCAL/REMOTE PUSH BUTTON ON BAY CONTROL UNIT
LOCAL = BCU REMOTE = HMI / SCADA
& &
SUBTATION LOCAL/REMOTE SELECTION FROM HMI
LOCAL = HMI
TO TRIP COIL - 1
OR
REMOTE = SCADA
TRIP COIL - 2
OPEN/CLOSE CONTROL FROM SCADA
CNTL SWTCH FROM C&R PANEL FOR EMERGENCY CONTROL **
OPEN
&
CLOSE
OPEN CLOSE
NOTE : **
EMERGENCY TRIPPING CAN BE GIVEN THROUGH THE TNC SWITCH PROVIDED ON THE BAY PROTECTION & CONTROL PANEL. CONTROLS GIVEN THROUGH TNC SWITCH ARE ROUTED INDEPENDENT OF THE BCU.
CLIENT PROJECT :
CONTROL LOGIC FOR REMOTE OPENING OF 400kV LINE-TIE- ICT CIRCUIT BREAKERS FROM SCADA
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
A
012
013
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL LOGIC FOR REMOTE CLOSING OF CIRCUIT BREAKERS FROM SCADA (LDC) *
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
EQP LOCAL/REMOTE LOCAL = EQP M.BOX SELECTOR SWITCH AT EQP MARSHALLING BOX REMOTE = BCU/HMI/SCADA
SELECTED INCOMING VOLTS
SELECTED RUNNING VOLTS
& BAY LOCAL/REMOTE PUSH BUTTON ON BAY CONTROL UNIT
SUBTATION LOCAL/REMOTE SELECTION FROM HMI
LOCAL = BCU REMOTE = HMI / SCADA
VALIDATION OF CHECK-SYNC CONDITIONS IN BCU**
&
LOCAL = HMI REMOTE = SCADA
TO CLOSING CIRCUIT
OR OPEN/CLOSE CONTROL FROM HMI
OPEN CLOSE
INTLKS IMPLEMENTED THROUGH SOFT LOGIC IN RESPECTIVE BCU *** ## PERMISSIVE FOR TNC MAINTENANCE CLOSING FROM BCU (APPLIES TO ALL BAYS EXCEPT GT & GT TIE BAYS)
INTLKS IMPLEMENTED THROUGH HARDWIRING IN BAY CNTL & PROT PANEL***
& CNTL SWTCH FROM C&R PANEL FOR EMERGENCY CONTROL
ISO 89-A OPEN
OPEN
&
CLOSE
PERMISSIVE
## PERMISSIVE FOR MAINTENANCE CLOSING
ISO 89-B OPEN
NOTE : **
CHECK SYNCHRONISATION CONDITIONS ARE VALIDATED IN THE RESPECTIVE BAY CONTROL UNIT, BASED UPON THE SELECTED INCOMING & RUNNING VOLTAGES.
***
FOR DETAILS INTERLOCKING LOGICS REFER THE INTERLOCKS OF THE RESPECTIVE CIRCUIT BREAKER.
##
PERMISSIVE FOR MAINTENANCE CLOSING IS GENERATED FROM BCU, WHEN BOTH THE ISOLATORS ON EITHER SIDES OF THE CB ARE OPEN. THIS OUTPUT CONTACT FROM BCU IS WIRED INTO THE TNC CLOSING CIRCUIT.
1
CLOSE COMMAND GIVEN BY THE OPERATOR FROM SCADA WILL BE EXECUTED ONLY IF THE CHECK-SYNC CONDITIONS ARE SATISFIED.
2
CLOSE COMMAND FROM TNC SWITCH IS MEANT FOR CLOSING WITHOUT ANY SYNCHRONISATION & HENCE TO BE USED FOR MAINTENANCE/TESTING CONDITIONS.
3
INCOMING & RUNNING VOLTS ARE SELECTED BASED UPON THE ISOLATOR & CB POSITIONS IN THE RESPECTIVE DIA.
CONTROL LOGIC FOR REMOTE CLOSING OF 400kV LINE-TIE- ICT CIRCUIT BREAKERS FROM SCADA
CLIENT ADANI POWER LTD. : 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT PROJECT : MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
A
013
014
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
INTERLOCK LOGIC FOR OPERATION OF ISOLATORS IN O/G LINE-1
A) ISOLATOR 1-89A BUS-2 CVT ISO CLOSED
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
BUS-2 CVT ES OPEN
& 1-89AE OPEN
ISO 1-89A INTLK PERMISSIVE*
1-52CB OPEN***
&
ISO 1-89A CLOSE ORDER
&
ISO 1-89A OPEN ORDER
ISO 1-89A CLOSE REQUEST**
ISO 1-89A OPEN REQUEST**
B) ISOLATOR 1-89B
1-89BE OPEN
& 1-52CB OPEN***
ISO 1-89B CLOSE REQUEST**
ISO 1-89B OPEN REQUEST**
ISO 1-89B INTLK PERMISSIVE*
&
&
ISO 1-89B CLOSE ORDER
ISO 1-89B OPEN ORDER
NOTE:
File: PG725000-003.xls
*
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-1
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
014
015
DF003
INTERLOCK LOGIC FOR OPERATION OF ISOLATORS IN O/G LINE-1 (CONTD)
C) ISOLATOR 1-89C 1-89LE OPEN
1-52CB OPEN***
&
ISO 1-89L INTLK PERMISSIVE *
2-52CB OPEN*** ISO 1-89L CLOSE REQUEST **
This drawing and design is the property of AREVA T&D and must not be copied or lent with
ISO 1-89L OPEN REQUEST **
&
&
ISO 1-89L CLOSE ORDER
ISO 1-89L OPEN ORDER
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-1 (CONTD)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
015
016
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN O/G LINE-1
A) EARTH SWITCH 1-89AE* ISO 1-89A OPEN
ES 1-89AE INTLK PERMISSIVE **
&
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ISO 1-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
B) EARTH SWITCH 1-89BE* ISO 1-89A OPEN
ES 1-89BE INTLK PERMISSIVE **
& ISO 1-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
C) EARTH SWITCH 1-89LE* ISO 1-89L OPEN
ES 1-89LE INTLK PERMISSIVE **
& DEAD LINE O/G LINE-1 (UNDER VOLTAGE OPERATED) ***
& OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
TO OPEN CIRCUIT
OPEN CLOSE
TO CLOSING CIRCUIT
& NOTE: *
FOR EARTH SWITCHES THERE IS NO REMOTE CONTROL FROM BCU/HMI/SCADA. CONTROL IS POSSIBLE ONLY FROM EQUIPMENT MARSHALLING BOX. ALL THE INTERLOCKS FOR EARTH SWITCH OPERATION ARE VERIFIED IN BCU & AN OUTPUT IS GENERATED FROM BCU WHEN THE INTERLOCKS ARE SATISFIED.
**
THIS INTERLOCK PERMISSIVE IS GENERATED BY THE BCU AND IS HARD WIRED IN THE CONTROL CIRCUIT OF THE EARTH SWITCH. COMMANDS GIVEN FROM THE EQUIPMENT MARSHALLING BOX ARE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
***
LINE U/V PERMISSIVE IS TAKEN THROUGH SOFT FROM LINE DISTANCE PROTECTION RELAY.
CLIENT PROJECT :
CONTROL & INTERLOCK LOGIC FOR OPERATION OF 400kV EARTH SWITCHES IN O/G LINE-1
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
016
017
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN O/G LINE-1
A) RUNNING VOLTS * RUNNING VOLTS
BUS - 2 CVT
B) INCOMING VOLTS ** CASE - I LINE - 1 CVT (1 - CVTB) SELECTED
ISO 1-89L CLOSE
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
CASE - 2 CB 3-52 CLOSE
CB 2-52 CLOSE
&
BUS-1 CVT SELECTED
ISO 3-89G OPEN
CB 1-89L OPEN
NOTE: *
FOR LINE FEEDERS, BUS-2 CVT WILL BE SELECTED AS RUNNING VOLTS AND EXTENDED TO BCU TERMINALS FOR CHECK-SYNC.
**
AT ANY TIME ONLY ONE OF THE CASES WILL BE SUCCESFUL FOR INCOMING VOLTS. BASED ON THE ISOLATOR & CB POSITIONS, THE LOGICS ARE VALIDATED AND OUTPUTS ARE GENERATED FROM THE BCU WHICH ARE WIRED INTO THE PT SELECTION CIRCUIT FOR EXTENSION OF THE APPROPRIATE INCOMING VOLTS TO BCU.
THE SYNCHRONISATION OF LINE WITH GT IS NOT CONSIDERED IN THE CVT SELECTION & THE CB CLOSING SCHEME.
CLIENT PROJECT :
CVT SELECTION LOGIC FOR CHECK-SYNC OF CB IN O/G LINE-1 (BAY-1)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
017
018
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN O/G LINE-1
A) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BMK LEVEL * ES 1-89 AE CLOSE
CB 1-52 LOCAL CLOSING CIRCUIT *
& This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ES 1-89 BE CLOSE
B) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BAY CONTROL & PROTECTION PANEL **
86-A TRIP RELAY RESET
86-B TRIP RELAY RESET
CB 1-52 CLOSING CIRCUIT **
& A/R LK-OUT TRIP RELAY (86-LO) RESET BBP RELAY RESET
C) INTERLOCKS IMPLEMENTED IN SOFT LOGIC IN BCU ***
86-A TRIP RELAY RESET RUNNING (BUS-2 CVT) VOLTS
86-B TRIP RELAY RESET A/R LK-OUT TRIP RELAY (86-LO) RESET BBP RELAY RESET ISO 1-89A CLOSE
&
VALIDATION OF CHECK-SYNC CONDITIONS IN BCU**
CB 1-52 CLOSE ORDER
ISO 1-89B CLOSE L/R SS AT CB 1-52 M.BOX IN REMOTE MODE
SELECTED INCOMING VOLTS (REFER SH: 017)
CLOSE REQUEST FROM BCU/SCADA/HMI TRIP CIRCUIT - 1 & 2 HEALTHY NOTE: *
THESE INTERLOCKS APPLY TO CLOSE OPERATION OF CIRCUIT BREAKER FROM THE EQUIPMENT MARSHALLING BOX.
**
THESE HARDWIRED INTERLOCKS APPLY TO THE CONTROL USING TNC SWITCH ON THE BAY CONTROL & PROTECTION PANEL. IN CASE OF CLOSING FROM BCU/HMI/SCADA, THESE HARDWIRED INTERLOCKS MUST BE SATISFIED IN ADDITION TO THE SOFT LOGICS BUILT IN THE BCU.
***
THESE LOGICS APPLY FOR THE CLOSE OPERATION FROM BCU/HMI/SCADA. THESE LOGICS APPLY FOR AUTO RECLOS CLOSE COMMAND ISSUED BY THE BCU. A/R CLOSING WILL SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH.
File: PG725000-003.xls
CLIENT
INTERLOCK LOGIC FOR CLOSING OF 400kV CIRCUIT BREAKER IN O/G LINE-1
PROJECT :
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
018
019
DF003
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN O/G LINE-1
A) INTERLOCKS FOR OPENING FROM BMK LEVEL * CB CLOSE ***
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
&
TO TRIP COIL - 1
TO TRIP COIL - 2 OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
OPEN CLOSE
B) INTERLOCKS FOR OPENING FROM REMOTE **
CB CLOSE ***
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
TO TRIP COIL - 1
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
& TO TRIP COIL - 2
CB OPEN REQUEST *
NOTE: *
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM EQP. MARSHALLING BOX.
**
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM BCU/HMI/SCADA. THESE LOGICS ARE BUILT IN THE BCU.
***
CB CLOSE POSITION IS CONFIRMED ONLY WHEN ALL THE THREE POLES ARE CLOSED.
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPENING OF 400kV CIRCUIT BREAKER IN O/G LINE-1
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
019
020
DF003
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN TIE-1
A) ISOLATOR 2-89A 2-89AE OPEN
& 2-52CB OPEN***
ISO 2-89A CLOSE REQUEST**
ISO 2-89A OPEN REQUEST**
ISO 2-89A INTLK PERMISSIVE *
&
ISO 2-89A CLOSE ORDER
&
ISO 2-89A OPEN ORDER
A) ISOLATOR 2-89B
ISO 2-89B INTLK PERMISSIVE *
2-89BE OPEN
2-52CB OPEN***
& &
ISO 2-89B CLOSE ORDER
&
ISO 2-89B OPEN ORDER
ISO 2-89B CLOSE REQUEST**
ISO 2-89B OPEN REQUEST**
File: PG725000-003.xls
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS FOR TIE-1
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
020
021
DF003
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN TIE-1
A) EARTH SWITCH 2-89AE*
ISO 2-89A OPEN
ES 2-89AE INTLK PERMISSIVE **
& ISO 2-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
B) EARTH SWITCH 2-89BE*
ISO 2-89A OPEN
ES 2-89BE INTLK PERMISSIVE **
& ISO 2-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
NOTE: *
FOR EARTH SWITCHES THERE IS NO REMOTE CONTROL FROM BCU/HMI/SCADA. CONTROL IS POSSIBLE ONLY FROM EQUIPMENT MARSHALLING BOX. ALL THE INTERLOCKS FOR EARTH SWITCH OPERATION ARE VERIFIED IN BCU & AN OUTPUT IS GENERATED FROM BCU WHEN THE INTERLOCKS ARE SATISFIED.
**
THIS INTERLOCK PERMISSIVE IS GENERATED BY THE BCU AND IS HARD WIRED IN THE CONTROL CIRCUIT OF THE EARTH SWITCH. COMMANDS GIVEN FROM THE EQUIPMENT MARSHALLING BOX ARE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
File: PG725000-003.xls
CLIENT PROJECT :
CONTROL & INTERLOCK LOGIC FOR OPERATION OF 400kV EARTH SWITCHES IN TIE1 (BAY-2)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
021
022
DF003
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN TIE-1
A) RUNNING VOLTS *
CASE-1
(TIE/GT SELECTOR SWITCH IN TIE MODE. SYNCHRONISATION IS DONE FROM SWITCHYARD BCU) BUS - 1 CVT
CASE-2
RUNNING VOLTS TO BCU
(TIE/GT SELECTOR SWITCH IN GT MODE. SYNCHRONISATION IS DONE FROM GCP) GT - 3 CVT
RUNNING VOLTS
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
B) INCOMING VOLTS * CASE - I
(APPLICABLE TO BOTH TIE & GCP MODE.)
ISO 1-89L CLOSE
TIE/GCP SELECTOR SWITCH AT SWYD BAY CONTROL & PROT PANEL CASE - 2
LINE - 1 CVT (1 - CVTB) SELECTED ** TIE = FEEDER
OR
&
GCP = GT (APPLICABLE TO BOTH TIE & GCP MODE.)
CB 1-52 CLOSE BUS-2 CVT SELECTED ** CB 1-89L OPEN
& TIE/GCP SELECTOR SWITCH AT SWYD BAY CONTROL & PROT PANEL
CASE - 3
TIE = FEEDER
OR
GCP = GT
(APPLICABLE FOR GT SYNCHRONISATION ONLY .TIE/GT SELECTOR SWITCH IN GT MODE. SYNCHRONISATION IS DONE FROM GCP)
CB 3-52 OPEN
## GT-3 CVT SELECTED **
CB 3-89G CLOSED
& TIE/GCP SELECTOR SWITCH AT SWYD BAY CONTROL & PROT PANEL
TIE = FEEDER GCP = GT
NOTE: *
SINCE THE SYNCHRONISATION OF GT IS DONE FROM GCP, GT CVT IS NOT CONSIDERED IN THE CVT SELECTION LOGIC FOR BCU. FOR BCU IN THE SWITCHYARD RUNNING VOLTS BY DEFAULT IS TAKEN AS BUS-1 VOLTS
**
AT ANY TIME ONLY ONE OF THE CASES WILL BE SUCCESFUL FOR INCOMING VOLTS. BASED ON THE ISOLATOR & CB POSITIONS, THE LOGICS ARE VALIDATED AND OUTPUTS ARE GENERATED FROM THE BCU WHICH ARE WIRED INTO THE PT SELECTION CIRCUIT FOR EXTENSION OF THE APPROPRIATE INCOMING VOLTS TO BCU.
##
GT-3 CVT WILL BE SELECTED ONLY FOR SYNCHRONISATION OF GT THROUGH THE TIE.
CLIENT PROJECT :
CVT SELECTION LOGIC FOR CHECK-SYNC OF CB IN TIE-1 (BAY-2)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
022
023
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN TIE-1 (REMOTE CLOSING POSSIBLE FROM SWITCHYARD ONLY AS LONG AS ISOLATOR 3-89G IS OPEN) A) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BMK LEVEL * ES 2-89 AE CLOSE
CB 2-52 LOCAL CLOSING CIRCUIT *
& This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ES 2-89 BE CLOSE B) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BAY CONTROL & PROTECTION PANEL ** O/G LINE-1 86-A TRIP RELAY RESET 86-B TRIP RELAY RESET GT-3 86 TRIP RELAY RESET A/R LK-OUT TRIP RELAY (86-LO) RESET TIE/GCP SELECTOR SWITCH AT SWYD BAY CONTROL & PROT PANEL
& TIE = FEEDER
CB 2-52 CLOSING CIRCUIT**
OR
GCP = GT
GT3 INTLKS FROM GCP
File: PG725000-003.xls
NOTE: *
THESE INTERLOCKS APPLY TO CLOSE OPERATION OF CIRCUIT BREAKER FROM THE EQUIPMENT MARSHALLING BOX.
**
THESE HARDWIRED INTERLOCKS APPLY TO THE CONTROL USING TNC SWITCH ON THE BAY CONTROL & PROTECTION PANEL. IN CASE OF CLOSING FROM BCU/HMI/SCADA, THESE HARDWIRED INTERLOCKS MUST BE SATISFIED IN ADDITION TO THE SOFT LOGICS BUILT IN THE BCU.
***
THESE LOGICS APPLY FOR THE CLOSE OPERATION FROM BCU/HMI/SCADA. THESE LOGICS APPLY FOR AUTO RECLOSE CLOSE COMMAND ISSUED BY THE BCU. A/R CLOSING WILL SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH.
CLIENT PROJECT :
INTERLOCK LOGIC FOR CLOSING OF 400kV CIRCUIT BREAKER IN TIE-1
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
023
023A
DF003
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN TIE-1 (CONTD.) (REMOTE CLOSING POSSIBLE FROM SWITCHYARD ONLY AS LONG AS TIE/GCP SELECTOR SWITCH IS IN TIE MODE)
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
C) INTERLOCKS IMPLEMENTED IN SOFT LOGIC IN BCU *** TIE-1 A/R LK-OUT TRIP RELAY (86-LO) RESET RUNNING (BUS-1 CVT) VOLTS
O/G LINE-1 86-A TRIP RELAY RESET 86-B TRIP RELAY RESET GT-3 86 TRIP RELAY RESET
VALIDATION OF CHECK-SYNC CONDITIONS IN BCU**
ISO 2-89A CLOSE
ISO 2-89B CLOSE
CB 2-52 CLOSE ORDER
&
ISO 3-89G OPEN
SELECTED INCOMING VOLTS (REFER SH: 022)
TRIP CIRCUIT - 1 & 2 HEALTHY L/R SS AT CB 2-52 M.BOX IN REMOTE MODE CLOSE REQUEST FROM BCU/SCADA/HMI
TIE/GCP SELECTOR SWITCH AT SWYD BAY CONTROL & PROT PANEL
TIE = FEEDER GCP = GT
File: PG725000-003.xls
NOTE: *
THESE INTERLOCKS APPLY TO CLOSE OPERATION OF CIRCUIT BREAKER FROM THE EQUIPMENT MARSHALLING BOX.
**
THESE HARDWIRED INTERLOCKS APPLY TO THE CONTROL USING TNC SWITCH ON THE BAY CONTROL & PROTECTION PANEL. IN CASE OF CLOSING FROM BCU/HMI/SCADA, THESE HARDWIRED INTERLOCKS MUST BE SATISFIED IN ADDITION TO THE SOFT LOGICS BUILT IN THE BCU.
***
CLIENT PROJECT :
THESE LOGICS APPLY FOR THE CLOSE OPERATION FROM BCU/HMI/SCADA. THESE LOGICS APPLY FOR AUTO RECLOSE CLOSE COMMAND ISSUED BY THE BCU. A/R CLOSING WILL SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH.
INTERLOCK LOGIC FOR CLOSING OF 400kV CIRCUIT BREAKER IN TIE-1(CONTD.)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
023A
024
DF003
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN TIE-1 (REMOTE OPENING POSSIBLE FROM SWITCHYARD ONLY IF TIE/GCP SELECTOR SWITCH IS IN TIE MODE) A) INTERLOCKS FOR OPENING FROM BMK LEVEL *
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
CB CLOSE ***
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
&
TO TRIP COIL - 1
TO TRIP COIL - 2 OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
OPEN CLOSE
B) INTERLOCKS FOR REMOTE OPENING **
CB CLOSE ***
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX
TO TRIP COIL - 1
REMOTE = BCU/HMI/SCADA TO TRIP COIL - 2
& CB OPEN REQUEST
3-89G OPEN
TIE/GCP SELECTOR SWITCH AT SWYD BAY CONTROL & PROT PANEL
TIE = FEEDER GCP = GT
NOTE: *
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM EQP. MARSHALLING BOX.
**
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM BCU/HMI/SCADA. THESE LOGICS ARE BUILT IN THE BCU.
***
CB CLOSE POSITION IS CONFIRMED ONLY WHEN ALL THE THREE POLES ARE CLOSED.
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPENING OF 400kV CIRCUIT BREAKER IN TIE-1
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
024
025
DF003
INTERLOCK LOGIC FOR OPERATION OF ISOLATORS IN GT-3
A) ISOLATOR 3-89B BUS-1 CVT ISO CLOSED
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
BUS-1 CVT ES OPEN
3-89BE OPEN
&
ISO 3-89B INTLK PERMISSIVE *
3-52CB OPEN***
&
ISO 3-89B CLOSE ORDER
&
ISO 3-89B OPEN ORDER
ISO 3-89B CLOSE REQUEST**
ISO 3-89B OPEN REQUEST**
B) ISOLATOR 3-89A
3-89AE OPEN
&
ISO 3-89A INTLK PERMISSIVE *
3-52CB OPEN***
ISO 3-89A CLOSE REQUEST**
ISO 3-89A OPEN REQUEST**
&
&
ISO 3-89A CLOSE ORDER
ISO 3-89A OPEN ORDER
NOTE:
File: PG725000-003.xls
*
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIEDCLIENT
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN GT-3 (BAY-3)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
025
026
DF003
INTERLOCK LOGIC FOR OPERATION OF ISOLATORS IN GT-3 (CONTD.)
C) ISOLATOR 3-89G 3-89GE OPEN
3-52CB OPEN***
&
ISO 3-89G INTLK PERMISSIVE*
2-52CB OPEN*** ISO 3-89G CLOSE REQUEST **
This drawing and design is the property of AREVA T&D and must not be copied or lent with
ISO 3-89G OPEN REQUEST **
&
&
ISO 3-89G CLOSE ORDER
ISO 3-89G OPEN ORDER
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN GT-3 (BAY-3)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
026
027
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN GT-3
A) EARTH SWITCH 3-89AE* ISO 3-89A OPEN
ES 3-89AE INTLK PERMISSIVE **
&
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ISO 3-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
B) EARTH SWITCH 3-89BE* ISO 3-89A OPEN
ES 3-89BE INTLK PERMISSIVE **
& ISO 3-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
C) EARTH SWITCH 3-89GE*
ES 3-89GE INTLK PERMISSIVE **
ISO 3-89G OPEN
& GENERATOR EXCITATION OFF
& OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
TO OPEN CIRCUIT
OPEN CLOSE
TO CLOSING CIRCUIT
& NOTE: *
FOR EARTH SWITCHES THERE IS NO REMOTE CONTROL FROM BCU/HMI/SCADA. CONTROL IS POSSIBLE ONLY FROM EQUIPMENT MARSHALLING BOX. ALL THE INTERLOCKS FOR EARTH SWITCH OPERATION ARE VERIFIED IN BCU & AN OUTPUT IS GENERATED FROM BCU WHEN THE INTERLOCKS ARE SATISFIED.
**
THIS INTERLOCK PERMISSIVE IS GENERATED BY THE BCU AND IS HARD WIRED IN THE CONTROL CIRCUIT OF THE EARTH SWITCH. COMMANDS GIVEN FROM THE EQUIPMENT MARSHALLING BOX ARE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
CLIENT PROJECT :
CONTROL & INTERLOCK LOGIC FOR OPERATION OF 400kV EARTH SWITCHES IN GT-3
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
027
028
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL & INTERLOCK LOGIC FOR OPENING & CLOSING OF CIRCUIT BREAKER IN GT-3
A) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BMK LEVEL FOR CLOSE OPERATION*
ES 3-89 AE CLOSE
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ES 3-89 BE CLOSE
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
OPEN
REMOTE = GCP
&
CB 3-52 LOCAL CLOSING CIRCUIT *
CLOSE
B) INTERLOCKS FOR CLOSING FROM REMOTE (GCP) EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = GCP
GT3 INTLKS FROM GCP OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
CB 3-52 REMOTE CLOSING CIRCUIT *
& OPEN CLOSE
C) INTERLOCKS FOR OPENING FROM BMK LEVEL * CB CLOSE **
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
&
TO TRIP COIL - 1
TO TRIP COIL - 2 OPEN/CLOSE PUSH BUTTON CONTROLS AT GCP
OPEN CLOSE
D) INTERLOCKS FOR OPENING FROM REMOTE (GCP) EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = GCP TO TRIP COIL - 1
GT3 INTLKS FROM GCP
File: PG725000-003.xls
NOTE:
OPEN/CLOSE PUSH BUTTON CONTROLS AT GCP
&
TO TRIP COIL - 2
OPEN CLOSE
CLIENT
*
THESE INTERLOCKS APPLY TO OPERATION OF CIRCUIT BREAKER FROM THE EQUIPMENT MARSHALLING BOX. OPERATION OF THE CIRCUIT BREAKERS IN GT BAYS IS NOT ALLOWED FROM THE BAY CONTROL & PROTECTION PANEL, BCU/HMI/SCADA.
**
CLOSE POSITION OF THE CIRCUIT BREAKER IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN.
CONTROL & INTERLOCK LOGIC FOR 400kV CIRCUIT BREAKER IN GT-3 (BAY-3)
PROJECT :
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
028
029
DF003
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-2
A) ISOLATOR 4-89A
BUS-2 CVT ISO CLOSED
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
BUS-2 CVT ES OPEN
& 4-89AE OPEN
ISO 4-89A INTLK PERMISSIVE *
4-52CB OPEN***
&
ISO 4-89A CLOSE ORDER
&
ISO 4-89A OPEN ORDER
ISO 4-89A CLOSE REQUEST**
ISO 4-89A OPEN REQUEST**
B) ISOLATOR 4-89B
4-89BE OPEN
& 4-52CB OPEN***
ISO 4-89B CLOSE REQUEST**
ISO 4-89B OPEN REQUEST**
ISO 4-89B INTLK PERMISSIVE *
&
&
ISO 4-89B CLOSE ORDER
ISO 4-89B OPEN ORDER
NOTE:
File: PG725000-003.xls
*
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-2
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
029
030
DF003
INTERLOCK LOGIC FOR OPERATION OF ISOLATORS IN O/G LINE-2 (CONTD.)
C) ISOLATOR 4-89L
4-89LE OPEN
4-52CB OPEN***
&
ISO 4-89L INTLK PERMISSIVE *
5-52CB OPEN*** ISO 4-89L CLOSE REQUEST **
This drawing and design is the property of AREVA T&D and must not be copied or lent witho
ISO 4-89L OPEN REQUEST **
&
&
ISO 4-89L CLOSE ORDER
ISO 4-89L OPEN ORDER
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-2(CONTD.)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
030
031
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN O/G LINE-2
A) EARTH SWITCH 4-89AE* ISO 4-89A OPEN
ES 4-89AE INTLK PERMISSIVE **
&
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ISO 4-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
B) EARTH SWITCH 4-89BE* ISO 4-89A OPEN
ES 4-89BE INTLK PERMISSIVE **
& ISO 4-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
C) EARTH SWITCH 4-89LE* ISO 4-89L OPEN
ES 4-89LE INTLK PERMISSIVE **
& DEAD LINE O/G LINE-2 (UNDER VOLTAGE OPERATED) ***
& OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
TO OPEN CIRCUIT
OPEN CLOSE
TO CLOSING CIRCUIT
& NOTE: *
FOR EARTH SWITCHES THERE IS NO REMOTE CONTROL FROM BCU/HMI/SCADA. CONTROL IS POSSIBLE ONLY FROM EQUIPMENT MARSHALLING BOX. ALL THE INTERLOCKS FOR EARTH SWITCH OPERATION ARE VERIFIED IN BCU & AN OUTPUT IS GENERATED FROM BCU WHEN THE INTERLOCKS ARE SATISFIED.
**
THIS INTERLOCK PERMISSIVE IS GENERATED BY THE BCU AND IS HARD WIRED IN THE CONTROL CIRCUIT OF THE EARTH SWITCH. COMMANDS GIVEN FROM THE EQUIPMENT MARSHALLING BOX ARE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
***
LINE U/V PERMISSIVE IS TAKEN THROUGH SOFT FROM LINE DISTANCE PROTECTION RELAY.
CLIENT PROJECT :
CONTROL & INTERLOCK LOGIC FOR OPERATION OF 400kV EARTH SWITCHES IN O/G LINE-2
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
031
032
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN O/G LINE-2
A) RUNNING VOLTS * RUNNING VOLTS
BUS - 2 CVT
B) INCOMING VOLTS ** CASE - I LINE - 2 CVT (4 - CVTB) SELECTED
ISO 4-89L CLOSE
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
CASE - 2 CB 5-52 CLOSE
CB 6-52 CLOSE
ISO 6-89G OPEN
&
BUS-1 CVT SELECTED
ISO 4-89L OPEN
CASE - 3
CB 5-52 CLOSE
ISO 6-89G CLOSE
ICT-1 CVT (6-CVT) SELECTED
&
ISO 4-89L OPEN
NOTE: *
FOR LINE FEEDERS, BUS-2 CVT WILL BE SELECTED AS RUNNING VOLTS AND EXTENDED TO BCU TERMINALS FOR CHECK-SYNC.
**
AT ANY TIME ONLY ONE OF THE CASES WILL BE SUCCESFUL FOR INCOMING VOLTS. BASED ON THE ISOLATOR & CB POSITIONS, THE LOGICS ARE VALIDATED AND OUTPUTS ARE GENERATED FROM THE BCU WHICH ARE WIRED INTO THE PT SELECTION CIRCUIT FOR EXTENSION OF THE APPROPRIATE INCOMING VOLTS TO BCU.
CLIENT PROJECT :
CVT SELECTION LOGIC FOR CHECK-SYNC OF CB IN O/G LINE-2 (BAY-4)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
032
033
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN O/G LINE-2
A) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BMK LEVEL * ES 4-89 AE CLOSE
CB 4-52 LOCAL CLOSING CIRCUIT *
& This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ES 4-89 BE CLOSE
B) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BAY CONTROL & PROTECTION PANEL ** 86-A TRIP RELAY RESET
86-B TRIP RELAY RESET
CB 4-52 CLOSING CIRCUIT **
& A/R LK-OUT TRIP RELAY (86-LO) RESET BBP RELAY RESET C) INTERLOCKS IMPLEMENTED IN SOFT LOGIC IN BCU *** 86-A TRIP RELAY RESET
RUNNING (BUS-2 CVT) VOLTS
86-B TRIP RELAY RESET A/R LK-OUT TRIP RELAY (86-LO) RESET BBP RELAY RESET ISO 4-89A CLOSE
&
VALIDATION OF CHECK-SYNC CONDITIONS IN BCU**
CB 4-52 CLOSE ORDER
ISO 4-89B CLOSE L/R SS AT CB 4-52 M.BOX IN REMOTE MODE
SELECTED INCOMING VOLTS (REFER SH: 032)
CLOSE REQUEST FROM BCU/SCADA/HMI TRIP CIRCUIT - 1 & 2 HEALTHY NOTE: *
THESE INTERLOCKS APPLY TO CLOSE OPERATION OF CIRCUIT BREAKER FROM THE EQUIPMENT MARSHALLING BOX.
**
THESE HARDWIRED INTERLOCKS APPLY TO THE CONTROL USING TNC SWITCH ON THE BAY CONTROL & PROTECTION PANEL. IN CASE OF CLOSING FROM BCU/HMI/SCADA, THESE HARDWIRED INTERLOCKS MUST BE SATISFIED IN ADDITION TO THE SOFT LOGICS BUILT IN THE BCU.
***
THESE LOGICS APPLY FOR THE CLOSE OPERATION FROM BCU/HMI/SCADA. THESE LOGICS APPLY FOR AUTO RECLOSE CLOSE COMMAND ISSUED BY THE BCU. A/R CLOSING WILL SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH.
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR CLOSING OF 400kV CIRCUIT BREAKER IN O/G LINE-2
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
033
034
DF003
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN O/G LINE-2
A) INTERLOCKS FOR OPENING FROM BMK LEVEL *
CB CLOSE ***
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
&
TO TRIP COIL - 1
TO TRIP COIL - 2 OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
OPEN CLOSE
B) INTERLOCKS FOR OPENING FROM REMOTE **
CB CLOSE ***
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
TO TRIP COIL - 1
& TO TRIP COIL - 2
CB OPEN REQUEST *
NOTE: *
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM EQP. MARSHALLING BOX.
**
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM BCU/HMI/SCADA. THESE LOGICS ARE BUILT IN THE BCU.
***
CB CLOSE POSITION IS CONFIRMED ONLY WHEN ALL THE THREE POLES ARE CLOSED.
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPENING OF 400kV CIRCUIT BREAKER IN O/G LINE-2
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
034
035
DF003
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN TIE-2
A) ISOLATOR 5-89A
5-89AE OPEN
&
ISO 5-89A INTLK PERMISSIVE*
5-52CB OPEN***
ISO 5-89A CLOSE REQUEST**
ISO 5-89A OPEN REQUEST**
&
ISO 5-89A CLOSE ORDER
&
ISO 5-89A OPEN ORDER
A) ISOLATOR 5-89B
ISO 5-89B INTLK PERMISSIVE*
5-89BE OPEN
& 5-52CB OPEN***
&
ISO 5-89B CLOSE ORDER
&
ISO 5-89B OPEN ORDER
ISO 5-89B CLOSE REQUEST**
ISO 5-89B OPEN REQUEST**
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN TIE-2
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
035
036
DF003
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN TIE-2
A) EARTH SWITCH 5-89AE* ISO 5-89A OPEN ES 5-89AE INTLK PERMISSIVE **
& ISO 5-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
B) EARTH SWITCH 5-89BE* ISO 5-89A OPEN ES 5-89BE INTLK PERMISSIVE **
& ISO 5-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
NOTE: *
FOR EARTH SWITCHES THERE IS NO REMOTE CONTROL FROM BCU/HMI/SCADA. CONTROL IS POSSIBLE ONLY FROM EQUIPMENT MARSHALLING BOX. ALL THE INTERLOCKS FOR EARTH SWITCH OPERATION ARE VERIFIED IN BCU & AN OUTPUT IS GENERATED FROM BCU WHEN THE INTERLOCKS ARE SATISFIED.
**
THIS INTERLOCK PERMISSIVE IS GENERATED BY THE BCU AND IS HARD WIRED IN THE CONTROL CIRCUIT OF THE EARTH SWITCH. COMMANDS GIVEN FROM THE EQUIPMENT MARSHALLING BOX ARE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
File: PG725000-003.xls
CLIENT PROJECT :
CONTROL & INTERLOCK LOGIC FOR OPERATION OF 400kV EARTH SWITCHES IN TIE-2 (BAY-5)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
036
037
DF003
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN TIE-2
A) RUNNING VOLTS * CASE - I ICT CVT (6 - CVT) SELECTED
ISO 6-89G CLOSE
CASE - 2 CB 6-52 CLOSE
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
&
BUS-1 CVT SELECTED
CB 6-89G OPEN
B) INCOMING VOLTS * CASE - I LINE - 2 CVT (4 - CVTB) SELECTED
ISO 4-89L CLOSE CASE - 2 CB 4-52 CLOSE
&
BUS-2 CVT SELECTED
CB 4-89L OPEN
NOTE:
*
AT ANY TIME ONLY ONE OF THE CASES WILL BE SUCCESFUL FOR INCOMING /RUNNING VOLTS. BASED ON THE ISOLATOR & CB POSITIONS, THE LOGICS ARE VALIDATED AND OUTPUTS ARE GENERATED FROM THE BCU WHICH ARE WIRED INTO THE PT SELECTION CIRCUIT FOR EXTENSION OF THE APPROPRIATE INCOMING/RUNNING VOLTS TO BCU.
CLIENT PROJECT :
CVT SELECTION LOGIC FOR CHECK-SYNC OF CB IN TIE-2 (BAY-5)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
037
038
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN TIE-2
A) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BMK LEVEL * ES 5-89 AE CLOSE
CB 5-52 LOCAL CLOSING CIRCUIT *
& This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ES 5-89 BE CLOSE B) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BAY CONTROL & PROTECTION PANEL ** O/G LINE-2 86-A TRIP RELAY RESET 86-B TRIP RELAY RESET
ICT-1 86-A TRIP RELAY RESET 86-B TRIP RELAY RESET
CB 5-52 CLOSING CIRCUIT**
&
TIE-2 A/R LK-OUT TRIP RELAY (86-LO) RESET
C) INTERLOCKS IMPLEMENTED IN SOFT LOGIC IN BCU *** TIE-2 A/R LK-OUT TRIP RELAY (86-LO) RESET SELECTED RUNNING VOLTS (REFER SH:037)
O/G LINE-2 86-A TRIP RELAY RESET 86-B TRIP RELAY RESET
ICT-1 86-A TRIP RELAY RESET 86-B TRIP RELAY RESET
& ISO 5-89A CLOSE
VALIDATION OF CHECK-SYNC CONDITIONS IN BCU**
CB 5-52 CLOSE ORDER
ISO 5-89B CLOSE
TRIP CIRCUIT - 1 & 2 HEALTHY
SELECTED INCOMING VOLTS (REFER SH: 037)
L/R SS AT CB 5-52 M.BOX IN REMOTE MODE CLOSE REQUEST FROM BCU/SCADA/HMI NOTE: *
THESE INTERLOCKS APPLY TO CLOSE OPERATION OF CIRCUIT BREAKER FROM THE EQUIPMENT MARSHALLING BOX.
**
THESE HARDWIRED INTERLOCKS APPLY TO THE CONTROL USING TNC SWITCH ON THE BAY CONTROL & PROTECTION PANEL. IN CASE OF CLOSING FROM BCU/HMI/SCADA, THESE HARDWIRED INTERLOCKS MUST BE SATISFIED IN ADDITION TO THE SOFT LOGICS BUILT IN THE BCU.
***
THESE LOGICS APPLY FOR THE CLOSE OPERATION FROM BCU/HMI/SCADA. THESE LOGICS APPLY FOR AUTO RECLOS CLOSE COMMAND ISSUED BY THE BCU. A/R CLOSING WILL SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH.
File: PG725000-003.xls
CLIENT
INTERLOCK LOGIC FOR CLOSING OF 400kV CIRCUIT BREAKER IN TIE-2
PROJECT :
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
038
039
DF003
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN TIE-2
A) INTERLOCKS FOR OPENING FROM BMK LEVEL *
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
CB CLOSE ***
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
&
TO TRIP COIL - 1
TO TRIP COIL - 2 OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
OPEN CLOSE
B) INTERLOCKS FOR REMOTE OPENING **
CB CLOSE ***
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
TO TRIP COIL - 1
& TO TRIP COIL - 2
CB OPEN REQUEST
NOTE: *
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM EQP. MARSHALLING BOX.
**
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM BCU/HMI/SCADA. THESE LOGICS ARE BUILT IN THE BCU.
***
CB CLOSE POSITION IS CONFIRMED ONLY WHEN ALL THE THREE POLES ARE CLOSED.
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPENING OF 400kV CIRCUIT BREAKER IN TIE-2
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
039
040
DF003
INTERLOCK LOGIC FOR OPERATION OF400kV ISOLATORS IN ICT-1
A) ISOLATOR 6-89B BUS-1 CVT ISO CLOSED
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
BUS-1 CVT ES OPEN
6-89BE OPEN
&
ISO 6-89B INTLK PERMISSIVE *
6-52CB OPEN***
&
ISO 6-89B CLOSE ORDER
&
ISO 6-89B OPEN ORDER
ISO 6-89B CLOSE REQUEST**
ISO 6-89B OPEN REQUEST**
B) ISOLATOR 6-89A
ISO 6-89A INTLK PERMISSIVE *
6-89AE OPEN
& 6-52CB OPEN***
&
ISO 6-89A CLOSE ORDER
&
ISO 6-89A OPEN ORDER
ISO 6-89A CLOSE REQUEST**
ISO 6-89A OPEN REQUEST**
NOTE:
File: PG725000-003.xls
*
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN ICT-1
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
040
041
DF003
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN ICT-1 (CONTD.)
C) ISOLATOR 6-89G 6-89GE OPEN
6-52CB OPEN***
&
ISO 6-89G INTLK PERMISSIVE *
5-52CB OPEN*** ISO 6-89G CLOSE REQUEST**
This drawing and design is the property of AREVA T&D and must not be copied or lent witho
ISO 6-89G OPEN REQUEST**
&
ISO 6-89G CLOSE ORDER
&
ISO 6-89G OPEN ORDER
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN ICT-1 (CONTD.)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
041
042
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN ICT-1
A) EARTH SWITCH 6-89AE* ISO 6-89A OPEN
ES 6-89AE INTLK PERMISSIVE **
&
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ISO 6-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
B) EARTH SWITCH 6-89BE* ISO 6-89A OPEN
ES 6-89BE INTLK PERMISSIVE **
& ISO 6-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
C) EARTH SWITCH 6-89GE*
ES 6-89GE INTLK PERMISSIVE **
ISO 6-89G OPEN
& ICT LV CB OPEN
& OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
TO OPEN CIRCUIT
OPEN CLOSE
TO CLOSING CIRCUIT
& NOTE: *
FOR EARTH SWITCHES THERE IS NO REMOTE CONTROL FROM BCU/HMI/SCADA. CONTROL IS POSSIBLE ONLY FROM EQUIPMENT MARSHALLING BOX. ALL THE INTERLOCKS FOR EARTH SWITCH OPERATION ARE VERIFIED IN BCU & AN OUTPUT IS GENERATED FROM BCU WHEN THE INTERLOCKS ARE SATISFIED.
**
THIS INTERLOCK PERMISSIVE IS GENERATED BY THE BCU AND IS HARD WIRED IN THE CONTROL CIRCUIT OF THE EARTH SWITCH. COMMANDS GIVEN FROM THE EQUIPMENT MARSHALLING BOX ARE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
CLIENT PROJECT :
CONTROL & INTERLOCK LOGIC FOR OPERATION OF 400kV EARTH SWITCHES IN ICT-1
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
042
043
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN ICT-1
A) RUNNING VOLTS * BUS - 1 CVT
RUNNING VOLTS
B) INCOMING VOLTS ** CASE - I ISO 4-89L CLOSE
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
CB 4-52 OPEN
&
LINE - 2 CVT (4 - CVTB) SELECTED
CB 5-52 CLOSE CASE - 2 ICT -1 CVT (6 - CVT) SELECTED
ISO 6-89G CLOSE CASE - 3 CB 4-52 CLOSE
CB 5-52 CLOSE
&
BUS-2 CVT SELECTED
ISO 6-89G OPEN
NOTE: *
FOR ICT BAYS, BUS-1 CVT WILL BE SELECTED AS RUNNING VOLTS AND EXTENDED TO BCU TERMINALS FOR CHECK-SYNC.
**
AT ANY TIME ONLY ONE OF THE CASES WILL BE SUCCESFUL FOR INCOMING VOLTS. BASED ON THE ISOLATOR & CB POSITIONS, THE LOGICS ARE VALIDATED AND OUTPUTS ARE GENERATED FROM THE BCU WHICH ARE WIRED INTO THE PT SELECTION CIRCUIT FOR EXTENSION OF THE APPROPRIATE INCOMING VOLTS TO BCU.
CLIENT PROJECT :
CVT SELECTION LOGIC FOR CHECK-SYNC OF CB IN ICT-1 (BAY-6)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
043
044
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN ICT-1
A) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BMK LEVEL * ES 6-89 AE CLOSE
CB 6-52 LOCAL CLOSING CIRCUIT *
& This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ES 6-89 BE CLOSE
B) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BAY CONTROL & PROTECTION PANEL ** 86-A TRIP RELAY RESET
86-B TRIP RELAY RESET
CB 6-52 CLOSING CIRCUIT **
&
BBP RELAY RESET
C) INTERLOCKS IMPLEMENTED IN SOFT LOGIC IN BCU *** 86-A TRIP RELAY RESET RUNNING (BUS-1 CVT) VOLTS
86-B TRIP RELAY RESET
BBP RELAY RESET ISO 6-89A CLOSE
&
VALIDATION OF CHECK-SYNC CONDITIONS IN BCU**
CB 6-52 CLOSE ORDER
ISO 6-89B CLOSE L/R SS AT CB 6-52 M.BOX IN REMOTE MODE
SELECTED INCOMING VOLTS (REFER SH: 043)
CLOSE REQUEST FROM BCU/SCADA/HMI TRIP CIRCUIT - 1 & 2 HEALTHY
File: PG725000-003.xls
NOTE: *
THESE INTERLOCKS APPLY TO CLOSE OPERATION OF CIRCUIT BREAKER FROM THE EQUIPMENT MARSHALLING BOX.
**
THESE HARDWIRED INTERLOCKS APPLY TO THE CONTROL USING TNC SWITCH ON THE BAY CONTROL & PROTECTION PANEL. IN CASE OF CLOSING FROM BCU/HMI/SCADA, THESE HARDWIRED INTERLOCKS MUST BE SATISFIED IN ADDITION TO THE SOFT LOGICS BUILT IN THE BCU.
***
THESE LOGICS APPLY FOR THE CLOSE OPERATION FROM BCU/HMI/SCADA. THESE LOGICS APPLY FOR AUTO RECLOSE CLOSE COMMAND ISSUED BY THE BCU. A/R CLOSING WILL SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH.
CLIENT PROJECT :
INTERLOCK LOGIC FOR CLOSING OF 400kV CIRCUIT BREAKER IN ICT-1
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
044
045
DF003
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN ICT-1
A) INTERLOCKS FOR OPENING FROM BMK LEVEL *
CB CLOSE ***
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
&
TO TRIP COIL - 1
TO TRIP COIL - 2 OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
OPEN CLOSE
B) INTERLOCKS FOR OPENING FROM REMOTE **
CB CLOSE ***
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
TO TRIP COIL - 1
& TO TRIP COIL - 2
CB OPEN REQUEST *
NOTE: *
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM EQP. MARSHALLING BOX.
**
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM BCU/HMI/SCADA. THESE LOGICS ARE BUILT IN THE BCU.
***
CB CLOSE POSITION IS CONFIRMED ONLY WHEN ALL THE THREE POLES ARE CLOSED.
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPENING OF 400kV CIRCUIT BREAKER IN ICT-1
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
045
046
DF003
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-3
A) ISOLATOR 7-89A BUS-2 CVT ISO CLOSED
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
BUS-2 CVT ES OPEN
& 7-89AE OPEN
ISO 7-89A INTLK PERMISSIVE *
7-52CB OPEN***
&
ISO 7-89A CLOSE ORDER
&
ISO 7-89A OPEN ORDER
ISO 7-89A CLOSE REQUEST**
ISO 7-89A OPEN REQUEST**
B) ISOLATOR 7-89B
7-89BE OPEN
& 7-52CB OPEN***
ISO 7-89B CLOSE REQUEST**
ISO 7-89B OPEN REQUEST**
ISO 7-89B INTLK PERMISSIVE *
&
&
ISO 7-89B CLOSE ORDER
ISO 7-89B OPEN ORDER
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-3
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
046
047
DF003
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-3 (CONTD.)
C) ISOLATOR 7-89L 7-89LE OPEN
7-52CB OPEN***
&
ISO 7-89L INTLK PERMISSIVE*
8-52CB OPEN*** ISO 7-89L CLOSE REQUEST **
This drawing and design is the property of AREVA T&D and must not be copied or lent without p
ISO 7-89L OPEN REQUEST **
&
&
ISO 7-89L CLOSE ORDER
ISO 7-89L OPEN ORDER
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-3 (CONTD.)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
047
048
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN O/G LINE-3
A) EARTH SWITCH 7-89AE* ISO 7-89A OPEN
ES 7-89AE INTLK PERMISSIVE **
&
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ISO 7-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
B) EARTH SWITCH 7-89BE* ISO 7-89A OPEN
ES 7-89BE INTLK PERMISSIVE **
& ISO 7-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
C) EARTH SWITCH 7-89LE* ISO 7-89L OPEN
ES 7-89LE INTLK PERMISSIVE **
& DEAD LINE O/G LINE-3 (UNDER VOLTAGE OPERATED) ***
& OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
TO OPEN CIRCUIT
OPEN CLOSE
TO CLOSING CIRCUIT
& NOTE: *
FOR EARTH SWITCHES THERE IS NO REMOTE CONTROL FROM BCU/HMI/SCADA. CONTROL IS POSSIBLE ONLY FROM EQUIPMENT MARSHALLING BOX. ALL THE INTERLOCKS FOR EARTH SWITCH OPERATION ARE VERIFIED IN BCU & AN OUTPUT IS GENERATED FROM BCU WHEN THE INTERLOCKS ARE SATISFIED.
**
THIS INTERLOCK PERMISSIVE IS GENERATED BY THE BCU AND IS HARD WIRED IN THE CONTROL CIRCUIT OF THE EARTH SWITCH. COMMANDS GIVEN FROM THE EQUIPMENT MARSHALLING BOX ARE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
***
LINE U/V PERMISSIVE IS TAKEN THROUGH SOFT FROM LINE DISTANCE PROTECTION RELAY.
CLIENT PROJECT :
CONTROL & INTERLOCK LOGIC FOR OPERATION OF 400kV EARTH SWITCHES IN O/G LINE-3
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
048
049
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN O/G LINE-3
A) RUNNING VOLTS * BUS - 2 CVT
RUNNING VOLTS
B) INCOMING VOLTS ** CASE - I LINE - 3 CVT (7 - CVTB) SELECTED
ISO 7-89L CLOSE
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
CASE - 2 CB 8-52 CLOSE
CB 9-52 CLOSE
&
BUS-1 CVT SELECTED
&
ICT-2 CVT (9-CVT) SELECTED
ISO 9-89G OPEN
ISO 7-89L OPEN CASE - 3 CB 8-52 CLOSE
ISO 7-89L OPEN
ISO 9-89G CLOSE
NOTE: *
FOR LINE FEEDERS, BUS-2 CVT WILL BE SELECTED AS RUNNING VOLTS AND EXTENDED TO BCU TERMINALS FOR CHECK-SYNC.
**
AT ANY TIME ONLY ONE OF THE CASES WILL BE SUCCESFUL FOR INCOMING VOLTS. BASED ON THE ISOLATOR & CB POSITIONS, THE LOGICS ARE VALIDATED AND OUTPUTS ARE GENERATED FROM THE BCU WHICH ARE WIRED INTO THE PT SELECTION CIRCUIT FOR EXTENSION OF THE APPROPRIATE INCOMING VOLTS TO BCU.
CLIENT PROJECT :
CVT SELECTION LOGIC FOR CHECK-SYNC OF CB IN O/G LINE-3 (BAY-7)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
049
050
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN O/G LINE-3
A) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BMK LEVEL *
ES 7-89 AE CLOSE
CB 7-52 LOCAL CLOSING CIRCUIT *
& This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ES 7-89 BE CLOSE
B) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BAY CONTROL & PROTECTION PANEL **
86-A TRIP RELAY RESET
86-B TRIP RELAY RESET
CB 7-52 CLOSING CIRCUIT **
& A/R LK-OUT TRIP RELAY (86-LO) RESET BBP RELAY RESET C) INTERLOCKS IMPLEMENTED IN SOFT LOGIC IN BCU ***
86-A TRIP RELAY RESET RUNNING (BUS-2 CVT) VOLTS
86-B TRIP RELAY RESET A/R LK-OUT TRIP RELAY (86-LO) RESET BBP RELAY RESET ISO 7-89A CLOSE
&
VALIDATION OF CHECK-SYNC CONDITIONS IN BCU**
CB 7-52 CLOSE ORDER
ISO 7-89B CLOSE L/R SS AT CB 7-52 M.BOX IN REMOTE MODE
SELECTED INCOMING VOLTS (REFER SH: 049)
CLOSE REQUEST FROM BCU/SCADA/HMI TRIP CIRCUIT - 1 & 2 HEALTHY NOTE: *
THESE INTERLOCKS APPLY TO CLOSE OPERATION OF CIRCUIT BREAKER FROM THE EQUIPMENT MARSHALLING BOX.
**
THESE HARDWIRED INTERLOCKS APPLY TO THE CONTROL USING TNC SWITCH ON THE BAY CONTROL & PROTECTION PANEL. IN CASE OF CLOSING FROM BCU/HMI/SCADA, THESE HARDWIRED INTERLOCKS MUST BE SATISFIED IN ADDITION TO THE SOFT LOGICS BUILT IN THE BCU.
***
THESE LOGICS APPLY FOR THE CLOSE OPERATION FROM BCU/HMI/SCADA. THESE LOGICS APPLY FOR AUTO RECLOS CLOSE COMMAND ISSUED BY THE BCU. A/R CLOSING WILL SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH.
File: PG725000-003.xls
CLIENT
INTERLOCK LOGIC FOR CLOSING OF 400kV CIRCUIT BREAKER IN O/G LINE-3
PROJECT :
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
050
051
DF003
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN O/G LINE-3
A) INTERLOCKS FOR OPENING FROM BMK LEVEL * CB CLOSE ***
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
&
TO TRIP COIL - 1
TO TRIP COIL - 2 OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
OPEN CLOSE
B) INTERLOCKS FOR REMOTE OPENING **
CB CLOSE ***
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
TO TRIP COIL - 1
& TO TRIP COIL - 2
CB OPEN REQUEST *
NOTE: *
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM EQP. MARSHALLING BOX.
**
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM BCU/HMI/SCADA. THESE LOGICS ARE BUILT IN THE BCU.
***
CB CLOSE POSITION IS CONFIRMED ONLY WHEN ALL THE THREE POLES ARE CLOSED.
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPENING OF 400kV CIRCUIT BREAKER IN O/G LINE-3
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
051
052
DF003
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN TIE-3
A) ISOLATOR 8-89A
8-89AE OPEN
& ISO 8-89A INTLK PERMISSIVE *
8-52CB OPEN***
ISO 8-89A CLOSE REQUEST**
ISO 8-89A OPEN REQUEST**
&
ISO 8-89A CLOSE ORDER
&
ISO 8-89A OPEN ORDER
A) ISOLATOR 8-89B
ISO 8-89B INTLK PERMISSIVE *
8-89BE OPEN
& 8-52CB OPEN***
&
ISO 8-89B CLOSE ORDER
ISO 8-89B CLOSE REQUEST**
ISO 8-89B OPEN REQUEST**
&
ISO 8-89B OPEN ORDER
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN TIE-3
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
052
053
DF003
CONTROL & INTERLOCK LOGIC FOR OPERATION OFEARTH SWITCHES IN TIE-3
A) EARTH SWITCH 8-89AE* ISO 8-89A OPEN
ES 8-89AE INTLK PERMISSIVE **
& ISO 8-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
B) EARTH SWITCH 8-89BE* ISO 8-89A OPEN
ES 8-89BE INTLK PERMISSIVE **
& ISO 8-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
NOTE: *
FOR EARTH SWITCHES THERE IS NO REMOTE CONTROL FROM BCU/HMI/SCADA. CONTROL IS POSSIBLE ONLY FROM EQUIPMENT MARSHALLING BOX. ALL THE INTERLOCKS FOR EARTH SWITCH OPERATION ARE VERIFIED IN BCU & AN OUTPUT IS GENERATED FROM BCU WHEN THE INTERLOCKS ARE SATISFIED.
**
THIS INTERLOCK PERMISSIVE IS GENERATED BY THE BCU AND IS HARD WIRED IN THE CONTROL CIRCUIT OF THE EARTH SWITCH. COMMANDS GIVEN FROM THE EQUIPMENT MARSHALLING BOX ARE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
File: PG725000-003.xls
CLIENT PROJECT :
CONTROL & INTERLOCK LOGIC FOR OPERATION OF 400kV EARTH SWITCHES IN TIE-3 (BAY-8)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
053
054
DF003
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN TIE-3
A) RUNNING VOLTS * CASE - I ICT -2 CVT (9 - CVT) SELECTED
ISO 9-89G CLOSE
CASE - 2 CB 9-52 CLOSE
&
BUS-1 CVT SELECTED
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
CB 9-89G OPEN
B) INCOMING VOLTS * CASE - I LINE - 3 CVT (7 - CVTB) SELECTED
ISO 7-89L CLOSE CASE - 2 CB 7-52 CLOSE
&
BUS-2 CVT SELECTED
CB 7-89L OPEN
NOTE:
*
AT ANY TIME ONLY ONE OF THE CASES WILL BE SUCCESFUL FOR INCOMING/RUNNING VOLTS. BASED ON THE ISOLATOR & CB POSITIONS, THE LOGICS ARE VALIDATED AND OUTPUTS ARE GENERATED FROM THE BCU WHICH ARE WIRED INTO THE PT SELECTION CIRCUIT FOR EXTENSION OF THE APPROPRIATE INCOMING/RUNNING VOLTS TO BCU.
CLIENT PROJECT :
CVT SELECTION LOGIC FOR CHECK-SYNC OF CB IN TIE-3 (BAY-8)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
054
055
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN TIE-3
A) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BMK LEVEL * ES 8-89 AE CLOSE
CB 8-52 LOCAL CLOSING CIRCUIT *
& This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ES 8-89 BE CLOSE B) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BAY CONTROL & PROTECTION PANEL ** O/G LINE-3 86-A TRIP RELAY RESET 86-B TRIP RELAY RESET ICT-2 86-A TRIP RELAY RESET 86-B TRIP RELAY RESET
CB 8-52 CLOSING CIRCUIT**
&
TIE-3 A/R LK-OUT TRIP RELAY (86-LO) RESET
C) INTERLOCKS IMPLEMENTED IN SOFT LOGIC IN BCU *** TIE-3 A/R LK-OUT TRIP RELAY (86-LO) RESET SELECTED RUNNING VOLTS (REFER SH:054)
O/G LINE-3 86-A TRIP RELAY RESET 86-B TRIP RELAY RESET
ICT-2 86-A TRIP RELAY RESET 86-B TRIP RELAY RESET
& ISO 8-89A CLOSE
VALIDATION OF CHECK-SYNC CONDITIONS IN BCU**
CB 8-52 CLOSE ORDER
ISO 8-89B CLOSE
TRIP CIRCUIT - 1 & 2 HEALTHY
SELECTED INCOMING VOLTS (REFER SH: 054)
L/R SS AT CB 8-52 M.BOX IN REMOTE MODE CLOSE REQUEST FROM BCU/SCADA/HMI
File: PG725000-003.xls
NOTE: *
THESE INTERLOCKS APPLY TO CLOSE OPERATION OF CIRCUIT BREAKER FROM THE EQUIPMENT MARSHALLING BOX.
**
THESE HARDWIRED INTERLOCKS APPLY TO THE CONTROL USING TNC SWITCH ON THE BAY CONTROL & PROTECTION PANEL. IN CASE OF CLOSING FROM BCU/HMI/SCADA, THESE HARDWIRED INTERLOCKS MUST BE SATISFIED IN ADDITION TO THE SOFT LOGICS BUILT IN THE BCU.
***
THESE LOGICS APPLY FOR THE CLOSE OPERATION FROM BCU/HMI/SCADA. THESE LOGICS APPLY FOR AUTO RECLOSE CLOSE COMMAND ISSUED BY THE BCU. A/R CLOSING WILL SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH.
CLIENT PROJECT :
INTERLOCK LOGIC FOR CLOSING OF 400kV CIRCUIT BREAKER IN TIE-3
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
055
056
DF003
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN TIE-3
A) INTERLOCKS FOR OPENING FROM BMK LEVEL * CB CLOSE ***
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
&
TO TRIP COIL - 1
TO TRIP COIL - 2 OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
OPEN CLOSE
B) INTERLOCKS FOR REMOTE OPENING **
CB CLOSE ***
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
TO TRIP COIL - 1
& TO TRIP COIL - 2
CB OPEN REQUEST
NOTE: *
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM EQP. MARSHALLING BOX.
**
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM BCU/HMI/SCADA. THESE LOGICS ARE BUILT IN THE BCU.
***
CB CLOSE POSITION IS CONFIRMED ONLY WHEN ALL THE THREE POLES ARE CLOSED.
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPENING OF 400kV CIRCUIT BREAKER IN TIE-3
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
056
057
DF003
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN ICT-2
A) ISOLATOR 9-89B BUS-1 CVT ISO CLOSED
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
BUS-1 CVT ES OPEN
9-89BE OPEN
&
ISO 9-89B INTLK PERMISSIVE *
9-52CB OPEN***
&
ISO 9-89B CLOSE ORDER
&
ISO 9-89B OPEN ORDER
ISO 9-89B CLOSE REQUEST**
ISO 9-89B OPEN REQUEST**
B) ISOLATOR 9-89A
ISO 9-89A INTLK PERMISSIVE *
9-89AE OPEN
& 9-52CB OPEN***
&
ISO 9-89A CLOSE ORDER
&
ISO 9-89A OPEN ORDER
ISO 9-89A CLOSE REQUEST**
ISO 9-89A OPEN REQUEST**
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN ICT-2
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
057
058
DF003
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN ICT-2 (CONTD.)
C) ISOLATOR 9-89G 9-89GE OPEN
8-52CB OPEN***
&
ISO 9-89G INTLK PERMISSIVE *
9-52CB OPEN*** ISO 9-89G CLOSE REQUEST**
This drawing and design is the property of AREVA T&D and must not be copied or lent wi
ISO 9-89G OPEN REQUEST**
&
&
ISO 9-89G CLOSE ORDER
ISO 9-89G OPEN ORDER
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN ICT-2 (CONTD.)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
058
059
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN ICT-2
A) EARTH SWITCH 9-89AE* ISO 9-89A OPEN
ES 9-89AE INTLK PERMISSIVE **
&
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ISO 9-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
B) EARTH SWITCH 9-89BE* ISO 9-89A OPEN
ES 9-89BE INTLK PERMISSIVE **
& ISO 9-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
C) EARTH SWITCH 9-89GE*
ES 9-89GE INTLK PERMISSIVE **
ISO 9-89G OPEN
& OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
TO OPEN CIRCUIT
OPEN CLOSE
TO CLOSING CIRCUIT
& NOTE: *
FOR EARTH SWITCHES THERE IS NO REMOTE CONTROL FROM BCU/HMI/SCADA. CONTROL IS POSSIBLE ONLY FROM EQUIPMENT MARSHALLING BOX. ALL THE INTERLOCKS FOR EARTH SWITCH OPERATION ARE VERIFIED IN BCU & AN OUTPUT IS GENERATED FROM BCU WHEN THE INTERLOCKS ARE SATISFIED.
**
THIS INTERLOCK PERMISSIVE IS GENERATED BY THE BCU AND IS HARD WIRED IN THE CONTROL CIRCUIT OF THE EARTH SWITCH. COMMANDS GIVEN FROM THE EQUIPMENT MARSHALLING BOX ARE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
CLIENT PROJECT :
CONTROL & INTERLOCK LOGIC FOR OPERATION OF 400kV EARTH SWITCHES IN ICT-2
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
059
060
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN ICT-2
A) RUNNING VOLTS * BUS - 1 CVT
RUNNING VOLTS
B) INCOMING VOLTS ** CASE - I ISO 7-89L CLOSE
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
CB 7-52 OPEN
&
LINE - 3 CVT (7 - CVTB) SELECTED
CB 8-52 CLOSE CASE - 2 ICT-2 CVT (9 - CVT) SELECTED
ISO 9-89G CLOSE CASE - 3 CB 7-52 CLOSE
CB 8-52 CLOSE
&
BUS-2 CVT SELECTED
ISO 9-89G OPEN
NOTE: *
FOR ICT BAYS, BUS-1 CVT WILL BE SELECTED AS RUNNING VOLTS AND EXTENDED TO BCU TERMINALS FOR CHECK-SYNC.
**
AT ANY TIME ONLY ONE OF THE CASES WILL BE SUCCESFUL FOR INCOMING/ RUNNING VOLTS. BASED ON THE ISOLATOR & CB POSITIONS, THE LOGICS ARE VALIDATED AND OUTPUTS ARE GENERATED FROM THE BCU WHICH ARE WIRED INTO THE PT SELECTION CIRCUIT FOR EXTENSION OF THE APPROPRIATE INCOMING/ RUNNING VOLTS TO BCU.
CLIENT PROJECT :
CVT SELECTION LOGIC FOR CHECK-SYNC OF CB IN ICT-2 (BAY-9)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
060
061
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN ICT-2
A) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BMK LEVEL * ES 9-89 AE CLOSE
CB 9-52 LOCAL CLOSING CIRCUIT *
& This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ES 9-89 BE CLOSE
B) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BAY CONTROL & PROTECTION PANEL ** 86-A TRIP RELAY RESET
86-B TRIP RELAY RESET
CB 9-52 CLOSING CIRCUIT **
&
BBP RELAY RESET
C) INTERLOCKS IMPLEMENTED IN SOFT LOGIC IN BCU *** 86-A TRIP RELAY RESET RUNNING (BUS-1 CVT) VOLTS
86-B TRIP RELAY RESET
BBP RELAY RESET ISO 9-89A CLOSE
&
VALIDATION OF CHECK-SYNC CONDITIONS IN BCU**
CB 9-52 CLOSE ORDER
ISO 9-89B CLOSE L/R SS AT CB 9-52 M.BOX IN REMOTE MODE
SELECTED INCOMING VOLTS (REFER SH: 060)
CLOSE REQUEST FROM BCU/SCADA/HMI TRIP CIRCUIT - 1 & 2 HEALTHY
File: PG725000-003.xls
NOTE:
*
THESE INTERLOCKS APPLY TO CLOSE OPERATION OF CIRCUIT BREAKER FROM THE EQUIPMENT MARSHALLING BOX.
**
THESE HARDWIRED INTERLOCKS APPLY TO THE CONTROL USING TNC SWITCH ON THE BAY CONTROL & PROTECTION PANEL. IN CASE OF CLOSING FROM BCU/HMI/SCADA, THESE HARDWIRED INTERLOCKS MUST BE SATISFIED IN ADDITION TO THE SOFT LOGICS BUILT IN THE BCU.
***
THESE LOGICS APPLY FOR THE CLOSE OPERATION FROM BCU/HMI/SCADA. THESE LOGICS APPLY FOR AUTO RECLOSE CLOSE COMMAND ISSUED BY THE BCU. A/R CLOSING WILL SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH.
CLIENT PROJECT :
INTERLOCK LOGIC FOR CLOSING OF 400kV CIRCUIT BREAKER IN ICT-2
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
061
062
DF003
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN O/G ICT-2
A) INTERLOCKS FOR OPENING FROM BMK LEVEL *
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
CB CLOSE ***
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
&
TO TRIP COIL - 1
TO TRIP COIL - 2 OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
OPEN CLOSE
B) INTERLOCKS FOR REMOTE OPENING **
CB CLOSE ***
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
TO TRIP COIL - 1
& TO TRIP COIL - 2
CB OPEN REQUEST *
NOTE: *
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM EQP. MARSHALLING BOX.
**
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM BCU/HMI/SCADA. THESE LOGICS ARE BUILT IN THE BCU.
***
CB CLOSE POSITION IS CONFIRMED ONLY WHEN ALL THE THREE POLES ARE CLOSED.
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPENING OF 400kV CIRCUIT BREAKER IN ICT-2
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
062
063
DF003
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-4
A) ISOLATOR 10-89A
BUS-2 CVT ISO CLOSED
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
BUS-2 CVT ES OPEN
& 10-89AE OPEN
ISO 10-89A INTLK PERMISSIVE *
10-52CB OPEN***
&
ISO 10-89A CLOSE ORDER
&
ISO 10-89A OPEN ORDER
ISO 10-89A CLOSE REQUEST**
ISO 10-89A OPEN REQUEST**
B) ISOLATOR 10-89B
10-89BE OPEN
& 10-52CB OPEN***
ISO 10-89B CLOSE REQUEST**
ISO 10-89B OPEN REQUEST**
ISO 10-89B INTLK PERMISSIVE *
&
&
ISO 10-89B CLOSE ORDER
ISO 10-89B OPEN ORDER
NOTE:
File: PG725000-003.xls
*
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIEDCLIENT
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-4
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
063
064
DF003
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-4 (CONTD.)
C) ISOLATOR 10-89L 10-89LE OPEN
10-52CB OPEN***
&
ISO 10-89L INTLK PERMISSIVE *
11-52CB OPEN*** ISO 10-89L CLOSE REQUEST **
This drawing and design is the property of AREVA T&D and must not be copied or lent with
ISO 10-89L OPEN REQUEST **
&
&
ISO 10-89L CLOSE ORDER
ISO 10-89L OPEN ORDER
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN O/G LINE-4 (CONTD.)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
064
065
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN O/G LINE-4
A) EARTH SWITCH 10-89AE* ISO 10-89A OPEN
ES 10-89AE INTLK PERMISSIVE **
&
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ISO 10-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
B) EARTH SWITCH 10-89BE* ISO 10-89A OPEN
ES 10-89BE INTLK PERMISSIVE **
& ISO 10-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
C) EARTH SWITCH 10-89LE* ISO 10-89L OPEN
ES 10-89LE INTLK PERMISSIVE **
& DEAD LINE O/G LINE-4 (UNDER VOLTAGE OPERATED) ***
& OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
TO OPEN CIRCUIT
OPEN CLOSE
TO CLOSING CIRCUIT
& NOTE: *
FOR EARTH SWITCHES THERE IS NO REMOTE CONTROL FROM BCU/HMI/SCADA. CONTROL IS POSSIBLE ONLY FROM EQUIPMENT MARSHALLING BOX. ALL THE INTERLOCKS FOR EARTH SWITCH OPERATION ARE VERIFIED IN BCU & AN OUTPUT IS GENERATED FROM BCU WHEN THE INTERLOCKS ARE SATISFIED.
**
THIS INTERLOCK PERMISSIVE IS GENERATED BY THE BCU AND IS HARD WIRED IN THE CONTROL CIRCUIT OF THE EARTH SWITCH. COMMANDS GIVEN FROM THE EQUIPMENT MARSHALLING BOX ARE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
***
LINE U/V PERMISSIVE IS TAKEN THROUGH SOFT FROM LINE DISTANCE PROTECTION RELAY.
CLIENT PROJECT :
CONTROL & INTERLOCK LOGIC FOR OPERATION OF 400kV EARTH SWITCHES IN O/G LINE-4
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
065
066
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN O/G LINE-4
A) RUNNING VOLTS * BUS - 2 CVT
RUNNING VOLTS
B) INCOMING VOLTS ** CASE - I LINE - 4 CVT (10 - CVTB) SELECTED
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ISO 10-89L CLOSE CASE - 2 CB 10-52 CLOSE
CB 11-52 CLOSE
&
BUS-1 CVT SELECTED
ISO 12-89G OPEN
ISO 10-89L OPEN
NOTE: *
FOR LINE FEEDERS, BUS-2 CVT WILL BE SELECTED AS RUNNING VOLTS AND EXTENDED TO BCU TERMINALS FOR CHECK-SYNC.
**
AT ANY TIME ONLY ONE OF THE CASES WILL BE SUCCESFUL FOR INCOMING VOLTS. BASED ON THE ISOLATOR & CB POSITIONS, THE LOGICS ARE VALIDATED AND OUTPUTS ARE GENERATED FROM THE BCU WHICH ARE WIRED INTO THE PT SELECTION CIRCUIT FOR EXTENSION OF THE APPROPRIATE INCOMING VOLTS TO BCU. THE SYNCHRONISATION OF LINE WITH GT IS NOT CONSIDERED IN THE CVT SELECTION & THE CB CLOSING SCHEME.
File: PG725000-003.xls
CLIENT PROJECT :
CVT SELECTION LOGIC FOR CHECK-SYNC OF CB IN O/G LINE-4 (BAY-10)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
066
067
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN O/G LINE-4
A) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BMK LEVEL * ES 10-89 AE CLOSE
CB 10-52 LOCAL CLOSING CIRCUIT *
& This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ES 10-89 BE CLOSE
B) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BAY CONTROL & PROTECTION PANEL ** 86-A TRIP RELAY RESET
86-B TRIP RELAY RESET
CB 10-52 CLOSING CIRCUIT **
& A/R LK-OUT TRIP RELAY (86-LO) RESET BBP RELAY RESET C) INTERLOCKS IMPLEMENTED IN SOFT LOGIC IN BCU *** 86-A TRIP RELAY RESET
RUNNING (BUS-2 CVT) VOLTS
86-B TRIP RELAY RESET A/R LK-OUT TRIP RELAY (86-LO) RESET BBP RELAY RESET ISO 10-89A CLOSE
&
VALIDATION OF CHECK-SYNC CONDITIONS IN BCU**
CB 10-52 CLOSE ORDER
ISO 10-89B CLOSE L/R SS AT CB 10-52 M.BOX IN REMOTE MODE
SELECTED INCOMING VOLTS (REFER SH: 066)
CLOSE REQUEST FROM BCU/SCADA/HMI TRIP CIRCUIT - 1 & 2 HEALTHY NOTE: *
THESE INTERLOCKS APPLY TO CLOSE OPERATION OF CIRCUIT BREAKER FROM THE EQUIPMENT MARSHALLING BOX.
**
THESE HARDWIRED INTERLOCKS APPLY TO THE CONTROL USING TNC SWITCH ON THE BAY CONTROL & PROTECTION PANEL. IN CASE OF CLOSING FROM BCU/HMI/SCADA, THESE HARDWIRED INTERLOCKS MUST BE SATISFIED IN ADDITION TO THE SOFT LOGICS BUILT IN THE BCU.
***
THESE LOGICS APPLY FOR THE CLOSE OPERATION FROM BCU/HMI/SCADA. THESE LOGICS APPLY FOR AUTO RECLOSE CLOSE COMMAND ISSUED BY THE BCU. A/R CLOSING WILL SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH.
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR CLOSING OF 400kV CIRCUIT BREAKER IN O/G LINE-4
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
067
068
DF003
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN O/G LINE-4
A) INTERLOCKS FOR OPENING FROM BMK LEVEL * CB CLOSE ***
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
&
TO TRIP COIL - 1
TO TRIP COIL - 2 OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
OPEN CLOSE
B) INTERLOCKS FOR REMOTE OPENING **
CB CLOSE ***
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
TO TRIP COIL - 1
& TO TRIP COIL - 2
CB OPEN REQUEST *
NOTE: *
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM EQP. MARSHALLING BOX.
**
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM BCU/HMI/SCADA. THESE LOGICS ARE BUILT IN THE BCU.
***
CB CLOSE POSITION IS CONFIRMED ONLY WHEN ALL THE THREE POLES ARE CLOSED.
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPENING OF 400kV CIRCUIT BREAKER IN O/G LINE-4
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
068
069
DF003
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN TIE-4
A) ISOLATOR 11-89A 11-89AE OPEN
& ISO 11-89A INTLK PERMISSIVE *
11-52CB OPEN***
ISO 11-89A CLOSE REQUEST**
ISO 11-89A OPEN REQUEST**
&
ISO 11-89A CLOSE ORDER
&
ISO 11-89A OPEN ORDER
A) ISOLATOR 11-89B
ISO 11-89B INTLK PERMISSIVE *
11-89BE OPEN
& 11-52CB OPEN***
&
ISO 11-89B CLOSE ORDER
&
ISO 11-89B OPEN ORDER
ISO 11-89B CLOSE REQUEST**
ISO 11-89B OPEN REQUEST**
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN TIE-4
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
069
070
DF003
CONTROL & INTERLOCK LOGIC FOR OPERATION OFEARTH SWITCHES IN TIE-4
A) EARTH SWITCH 11-89AE* ISO 11-89A OPEN
ES 11-89AE INTLK PERMISSIVE **
& ISO 11-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
B) EARTH SWITCH 11-89BE* ISO 11-89A OPEN
ES 11-89BE INTLK PERMISSIVE **
& ISO 11-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
NOTE: *
FOR EARTH SWITCHES THERE IS NO REMOTE CONTROL FROM BCU/HMI/SCADA. CONTROL IS POSSIBLE ONLY FROM EQUIPMENT MARSHALLING BOX. ALL THE INTERLOCKS FOR EARTH SWITCH OPERATION ARE VERIFIED IN BCU & AN OUTPUT IS GENERATED FROM BCU WHEN THE INTERLOCKS ARE SATISFIED.
**
THIS INTERLOCK PERMISSIVE IS GENERATED BY THE BCU AND IS HARD WIRED IN THE CONTROL CIRCUIT OF THE EARTH SWITCH. COMMANDS GIVEN FROM THE EQUIPMENT MARSHALLING BOX ARE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
File: PG725000-003.xls
CLIENT PROJECT :
CONTROL & INTERLOCK LOGIC FOR OPERATION OF 400kV EARTH SWITCHES IN TIE-4 (BAY-11)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
070
071
DF003
CVT SELECTION LOGIC FOR CHECK SYNC OF CIRCUIT BREAKER IN TIE-4
A) RUNNING VOLTS *
CASE-1
(TIE/GT SELECTOR SWITCH IN TIE MODE. SYNCHRONISATION IS DONE FROM SWITCHYARD BCU) BUS - 1 CVT
CASE-2
RUNNING VOLTS TO BCU
(TIE/GT SELECTOR SWITCH IN GT MODE. SYNCHRONISATION IS DONE FROM GCP) GT - 4 CVT
RUNNING VOLTS
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
B) INCOMING VOLTS * CASE - I
(APPLICABLE TO BOTH TIE & GCP MODE.)
ISO 10-89L CLOSE
TIE/GCP SELECTOR SWITCH AT SWYD BAY CONTROL & PROT PANEL CASE - 2
LINE - 4 CVT (10 - CVTB) SELECTED ** TIE = FEEDER
OR
&
GCP = GT (APPLICABLE TO BOTH TIE & GCP MODE.)
CB 10-52 CLOSE BUS-2 CVT SELECTED ** CB 10-89L OPEN
& TIE/GCP SELECTOR SWITCH AT SWYD BAY CONTROL & PROT PANEL
CASE - 3
TIE = FEEDER
OR
GCP = GT
(APPLICABLE FOR GT SYNCHRONISATION ONLY .TIE/GT SELECTOR SWITCH IN GT MODE. SYNCHRONISATION IS DONE FROM GCP)
CB 12-52 OPEN
## GT-4 CVT SELECTED **
CB 12-89G CLOSED
& TIE/GCP SELECTOR SWITCH AT SWYD BAY CONTROL & PROT PANEL
TIE = FEEDER GCP = GT
NOTE: *
SINCE THE SYNCHRONISATION OF GT IS DONE FROM GCP, GT CVT IS NOT CONSIDERED IN THE CVT SELECTION LOGIC FOR BCU. FOR BCU IN THE SWITCHYARD RUNNING VOLTS BY DEFAULT IS TAKEN AS BUS-1 VOLTS
**
AT ANY TIME ONLY ONE OF THE CASES WILL BE SUCCESFUL FOR INCOMING VOLTS. BASED ON THE ISOLATOR & CB POSITIONS, THE LOGICS ARE VALIDATED AND OUTPUTS ARE GENERATED FROM THE BCU WHICH ARE WIRED INTO THE PT SELECTION CIRCUIT FOR EXTENSION OF THE APPROPRIATE INCOMING VOLTS TO BCU.
##
GT-3 CVT WILL BE SELECTED ONLY FOR SYNCHRONISATION OF GT THROUGH THE TIE.
CLIENT PROJECT :
CVT SELECTION LOGIC FOR CHECK-SYNC OF CB IN TIE-4 (BAY-11)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
071
072
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN TIE-4 (REMOTE CLOSING POSSIBLE FROM SWITCHYARD ONLY AS LONG AS TIE/GCP SELECTOR SWITCH IS IN TIE MODE) A) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BMK LEVEL * ES 11-89 AE CLOSE
CB 11-52 LOCAL CLOSING CIRCUIT *
& This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ES 11-89 BE CLOSE B) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BAY CONTROL & PROTECTION PANEL ** O/G LINE-4 86-A TRIP RELAY RESET 86-B TRIP RELAY RESET GT-4 86 TRIP RELAY RESET A/R LK-OUT TRIP RELAY (86-LO) RESET TIE/GCP SELECTOR SWITCH AT SWYD BAY CONTROL & PROT PANEL
& TIE = FEEDER
CB 11-52 CLOSING CIRCUIT**
OR
GCP = GT
GT4 INTLKS FROM GCP
File: PG725000-003.xls
NOTE: *
THESE INTERLOCKS APPLY TO CLOSE OPERATION OF CIRCUIT BREAKER FROM THE EQUIPMENT MARSHALLING BOX.
**
THESE HARDWIRED INTERLOCKS APPLY TO THE CONTROL USING TNC SWITCH ON THE BAY CONTROL & PROTECTION PANEL. IN CASE OF CLOSING FROM BCU/HMI/SCADA, THESE HARDWIRED INTERLOCKS MUST BE SATISFIED IN ADDITION TO THE SOFT LOGICS BUILT IN THE BCU.
***
THESE LOGICS APPLY FOR THE CLOSE OPERATION FROM BCU/HMI/SCADA. THESE LOGICS APPLY FOR AUTO RECLOSE CLOSE COMMAND ISSUED BY THE BCU. A/R CLOSING WILL SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH.
CLIENT PROJECT :
INTERLOCK LOGIC FOR CLOSING OF 400kV CIRCUIT BREAKER IN TIE-4
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
072
072A
DF003
INTERLOCK LOGIC FOR CLOSING OF CIRCUIT BREAKER IN TIE-4 (REMOTE CLOSING POSSIBLE FROM SWITCHYARD ONLY AS LONG AS TIE/GCP SELECTOR SWITCH IS IN TIE MODE)
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
C) INTERLOCKS IMPLEMENTED IN SOFT LOGIC IN BCU *** TIE-4 A/R LK-OUT TRIP RELAY (86-LO) RESET RUNNING (BUS-1 CVT) VOLTS
O/G LINE-4 86-A TRIP RELAY RESET 86-B TRIP RELAY RESET GT-4 86 TRIP RELAY RESET
VALIDATION OF CHECK-SYNC CONDITIONS IN BCU**
ISO 11-89A CLOSE
ISO 11-89B CLOSE
CB 11-52 CLOSE ORDER
&
ISO 12-89G OPEN
SELECTED INCOMING VOLTS (REFER SH: 070)
TRIP CIRCUIT - 1 & 2 HEALTHY L/R SS AT CB 11-52 M.BOX IN REMOTE MODE CLOSE REQUEST FROM BCU/SCADA/HMI
TIE/GCP SELECTOR SWITCH AT SWYD BAY CONTROL & PROT PANEL
TIE = FEEDER GCP = GT
File: PG725000-003.xls
NOTE: *
THESE INTERLOCKS APPLY TO CLOSE OPERATION OF CIRCUIT BREAKER FROM THE EQUIPMENT MARSHALLING BOX.
**
THESE HARDWIRED INTERLOCKS APPLY TO THE CONTROL USING TNC SWITCH ON THE BAY CONTROL & PROTECTION PANEL. IN CASE OF CLOSING FROM BCU/HMI/SCADA, THESE HARDWIRED INTERLOCKS MUST BE SATISFIED IN ADDITION TO THE SOFT LOGICS BUILT IN THE BCU.
***
CLIENT PROJECT :
THESE LOGICS APPLY FOR THE CLOSE OPERATION FROM BCU/HMI/SCADA. THESE LOGICS APPLY FOR AUTO RECLOSE CLOSE COMMAND ISSUED BY THE BCU. A/R CLOSING WILL SUCCESFUL ONLY IF THE INTERLOCKS ARE THROUGH.
INTERLOCK LOGIC FOR CLOSING OF 400kV CIRCUIT BREAKER IN TIE-4
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
072A
073
DF003
INTERLOCK LOGIC FOR OPENING OF CIRCUIT BREAKER IN TIE-4 (REMOTE OPENING POSSIBLE FROM SWITCHYARD ONLY IF TIE/GCP SELECTOR SWITCH IS IN TIE MODE) A) INTERLOCKS FOR OPENING FROM BMK LEVEL *
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
CB CLOSE ***
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
&
TO TRIP COIL - 1
TO TRIP COIL - 2 OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
OPEN CLOSE
B) INTERLOCKS FOR REMOTE OPENING **
CB CLOSE ***
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
TO TRIP COIL - 1
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
TO TRIP COIL - 2
& CB OPEN REQUEST
12-89G OPEN
TIE/GCP SELECTOR SWITCH AT SWYD BAY CONTROL & PROT PANEL
TIE = FEEDER GCP = GT
NOTE: *
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM EQP. MARSHALLING BOX.
**
THESE INTERLOCKS ARE APPLICABLE FOR OPERATION FROM BCU/HMI/SCADA. THESE LOGICS ARE BUILT IN THE BCU.
***
CB CLOSE POSITION IS CONFIRMED ONLY WHEN ALL THE THREE POLES ARE CLOSED.
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPENING OF 400kV CIRCUIT BREAKER IN TIE-4
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
073
074
DF003
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN GT-4
A) ISOLATOR 12-89B
BUS-1 CVT ISO CLOSED
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
BUS-1 CVT ES OPEN
12-89BE OPEN
&
ISO 12-89B INTLK PERMISSIVE *
12-52CB OPEN***
&
ISO 12-89B CLOSE ORDER
&
ISO 12-89B OPEN ORDER
ISO 12-89B CLOSE REQUEST**
ISO 12-89B OPEN REQUEST**
B) ISOLATOR 12-89A
12-89AE OPEN
&
ISO 12-89A INTLK PERMISSIVE *
12-52CB OPEN***
ISO 12-89A CLOSE REQUEST**
ISO 12-89A OPEN REQUEST**
&
&
ISO 12-89A CLOSE ORDER
ISO 12-89A OPEN ORDER
NOTE:
File: PG725000-003.xls
*
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN GT-4
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
A
074
075
DF003
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN GT-4 (CONTD.)
C) ISOLATOR 12-89G 12-89GE OPEN
12-52CB OPEN***
&
ISO 12-89G INTLK PERMISSIVE*
11-52CB OPEN*** ISO 12-89G CLOSE REQUEST**
This drawing and design is the property of AREVA T&D and must not be copied or lent wi
ISO 12-89G OPEN REQUEST**
&
&
ISO 12-89G CLOSE ORDER
ISO 12-89G OPEN ORDER
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
***
OPEN POSITION FOR CB IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR OPERATION OF 400kV ISOLATORS IN GT-4 (CONTD.)
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
A
075
076
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL & INTERLOCK LOGIC FOR OPERATION OF EARTH SWITCHES IN GT-4
A) EARTH SWITCH 12-89AE* ISO 12-89A OPEN
ES 12-89AE INTLK PERMISSIVE **
&
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ISO 12-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
B) EARTH SWITCH 12-89BE* ISO 12-89A OPEN
ES 12-89BE INTLK PERMISSIVE **
& ISO 12-89B OPEN
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
&
TO OPEN CIRCUIT
&
TO CLOSING CIRCUIT
OPEN CLOSE
C) EARTH SWITCH 12-89GE*
ES 12-89GE INTLK PERMISSIVE **
ISO 12-89G OPEN
& GENERATOR EXCITATION OFF OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
TO OPEN CIRCUIT
& OPEN CLOSE
TO CLOSING CIRCUIT
& NOTE: *
FOR EARTH SWITCHES THERE IS NO REMOTE CONTROL FROM BCU/HMI/SCADA. CONTROL IS POSSIBLE ONLY FROM EQUIPMENT MARSHALLING BOX. ALL THE INTERLOCKS FOR EARTH SWITCH OPERATION ARE VERIFIED IN BCU & AN OUTPUT IS GENERATED FROM BCU WHEN THE INTERLOCKS ARE SATISFIED.
**
THIS INTERLOCK PERMISSIVE IS GENERATED BY THE BCU AND IS HARD WIRED IN THE CONTROL CIRCUIT OF THE EARTH SWITCH. COMMANDS GIVEN FROM THE EQUIPMENT MARSHALLING BOX ARE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
File: PG725000-003.xls
CLIENT PROJECT :
CONTROL & INTERLOCK LOGIC FOR OPERATION OF 400kV EARTH SWITCHES IN GT-4
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
B
076
077
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
CONTROL & INTERLOCK LOGIC FOR OPENING & CLOSING OF CIRCUIT BREAKER IN GT-4
A) INTERLOCKS IMPLEMENTED AS HARDWIRED AT BMK LEVEL FOR CLOSE OPERATION*
ES 12-89 AE CLOSE
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
ES 12-89 BE CLOSE
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = GCP
&
CB 12-52 LOCAL CLOSING CIRCUIT *
OPEN CLOSE
B) INTERLOCKS FOR CLOSING FROM REMOTE (GCP) EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = GCP
GT4 INTLKS FROM GCP OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
CB 12-52 REMOTE CLOSING CIRCUIT *
& OPEN CLOSE
C) INTERLOCKS FOR OPENING FROM BMK LEVEL * CB CLOSE **
EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = BCU/HMI/SCADA
&
TO TRIP COIL - 1
TO TRIP COIL - 2 OPEN/CLOSE PUSH BUTTON CONTROLS AT GCP
OPEN CLOSE
D) INTERLOCKS FOR OPENING FROM REMOTE (GCP) EQP LOCAL/REMOTE SELECTOR SWITCH AT EQP MARSHALLING BOX
LOCAL = EQP M.BOX REMOTE = GCP TO TRIP COIL - 1
GT4 INTLKS FROM GCP
OPEN/CLOSE PUSH BUTTON CONTROLS AT GCP
&
TO TRIP COIL - 2
OPEN CLOSE
CLIENT
File: PG725000-003.xls
NOTE: *
OPERATION OF THE CIRCUIT BREAKERS IN GT BAYS IS NOT ALLOWED FROM THE BAY CONTROL & PROTECTION PANEL, BCU/HMI/SCADA.
**
CLOSE POSITION OF THE CIRCUIT BREAKER IS CONFIRMED ONLY IF ALL THE THREE POLES ARE OPEN.
CONTROL & INTERLOCK LOGIC FOR 400kV CIRCUIT BREAKER IN GT-4 (BAY-12)
PROJECT :
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET NEXT SH.
AREVA T&D India Limited
EMI-7604PG754-4-028
B
077
078
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writin
DF003
BLANK SHEET
File: PG725000-003.xls
CLIENT PROJECT :
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA BLANK SHEET
REV.
SHEET
NEXT SH.
A
078
079
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
INTERLOCK LOGIC FOR OPERATION OF BUS-1 CVT ISOLATOR & EARTH SWITCH (MANAGED BY TIE-1 BCU)
A) BUS - 1 CVT ISOLATOR
BUS-1 CVT ISO INTLK PERMISSIVE *
BUS-1 CVT EARTH SWITCH OPEN
BUS-1 CVT ISO CLOSE REQUEST **
BUS-1 CVT ISO OPEN REQUEST **
&
BUS-1 CVT ISO CLOSE ORDER
&
BUS-1 CVT ISO OPEN ORDER
# B) BUS-1 CVT EARTH SWITCH ## BUS-1 CVT E/S INTLK PERMISSIVE
This drawing and design is the property of AREVA T&D and must not be
BUS-1 CVT ISO OPEN
& OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
TO OPEN CIRCUIT
OPEN CLOSE
TO CLOSING CIRCUIT
&
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
#
FOR EARTH SWITCHES THERE IS NO REMOTE CONTROL FROM BCU/HMI/SCADA. CONTROL IS POSSIBLE ONLY FROM EQUIPMENT MARSHALLING BOX. ALL THE INTERLOCKS FOR EARTH SWITCH OPERATION ARE VERIFIED IN BCU & AN OUTPUT IS GENERATED FROM BCU WHEN THE INTERLOCKS ARE SATISFIED.
##
THIS INTERLOCK PERMISSIVE IS GENERATED BY THE BCU AND IS HARD WIRED IN THE CONTROL CIRCUIT OF THE EARTH SWITCH. COMMANDS GIVEN FROM THE EQUIPMENT MARSHALLING BOX ARE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR REMOTE OPERATION OF 400kV BUS-1 CVT ISOLATOR & EARTH SWITCH
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
A
079
080
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
INTERLOCK LOGIC FOR OPERATION OF BUS-2 CVT ISOLATOR & EARTH SWITCH (MANAGED BY TIE-1 BCU)
A) BUS - 2 CVT ISOLATOR
BUS-2 CVT EARTH SWITCH OPEN
BUS-2 CVT ISO INTLK PERMISSIVE *
BUS-2 CVT ISO CLOSE REQUEST **
BUS-2 CVT ISO OPEN REQUEST **
&
BUS-2 CVT ISO CLOSE ORDER
&
BUS-2 CVT ISO OPEN ORDER
# B) BUS-2 CVT EARTH SWITCH ## BUS-2 CVT E/S INTLK PERMISSIVE
This drawing and design is the property of AREVA T&D and must not be
BUS-2 CVT ISO OPEN
& OPEN/CLOSE PUSH BUTTON CONTROLS AT EQP MARSHALLING BOX
TO OPEN CIRCUIT
OPEN CLOSE
TO CLOSING CIRCUIT
&
NOTE: *
AS INDICATED IN SHEETS: 003, 004, 005, 006 FOR CONTROL LOGIC OF ISOLATORS, THE INTERLOCK PERMISSIVE WILL BE WIRED IN THE CONTROL CIRCUIT OF ISOLATORS TO ENSURE THAT COMMAND WILL BE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
**
CLOSING & OPENING REQUEST OF ISOLATORS CAN BE GIVEN FROM ANY CONTROL LEVELS DEFINED IN SHEETS 003-006, PROVIDED THE ABOVE INTERLOCKS ARE SATISFIED.
#
FOR EARTH SWITCHES THERE IS NO REMOTE CONTROL FROM BCU/HMI/SCADA. CONTROL IS POSSIBLE ONLY FROM EQUIPMENT MARSHALLING BOX. ALL THE INTERLOCKS FOR EARTH SWITCH OPERATION ARE VERIFIED IN BCU & AN OUTPUT IS GENERATED FROM BCU WHEN THE INTERLOCKS ARE SATISFIED.
##
THIS INTERLOCK PERMISSIVE IS GENERATED BY THE BCU AND IS HARD WIRED IN THE CONTROL CIRCUIT OF THE EARTH SWITCH. COMMANDS GIVEN FROM THE EQUIPMENT MARSHALLING BOX ARE EXECUTED ONLY WHEN THE INTERLOCKS ARE SATISFIED.
File: PG725000-003.xls
CLIENT PROJECT :
INTERLOCK LOGIC FOR REMOTE OPERATION OF 400kV BUS-2 CVT ISOLATOR & EARTH SWITCH
:
ADANI POWER LTD. 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT MUNDRA SEZ
AREVA
REV.
SHEET
NEXT SH.
A
080
081
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
IMPLEMENATION OF SYNCHROCHECK FUNCTION IN BCU (TYPICAL FOR ALL BAYS EXCEPT GT BAYS)
CASE -1 DEAD INCOMING VOLTS - DEAD RUNNING VOLTS IMPLEMENTED IN BCU
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
SELECTED RUNNING VOLTS *
RUNNING VOLTS < SELECTED DEAD VOLTS THRESHOLD
DEAD INCOMING VOLTS & DEAD RUNNING VOLTS CONDITIONS SATISFIED?
SELECTED INCOMING VOLTS *
INCOMING VOLTS < SELECTED DEAD VOLTS THRESHOLD
CLOSE REQUEST FROM BCU/HMI/SCADA
SOFTWARE INTERLOCKS BUILT IN RESPECTIVE BCU VERIFIED SUCCESFULLY **
YES TIMER FOR CONFIRMATION (SETTABLE) ***
&
TO CLOSING CIRCUIT
INTLKS IMPLEMENTED THROUGH HARDWIRING IN BAY CNTL & PROT PANEL
NOTE : *
VOLTAGE SELECTION FOR INCOMING AND RUNNING VOLTS SHALL BE AS PER THE SELECTION LOGIC INDICATED IN THE RESPECTIVE BAY INTERLOCK LOGICS.
**
SOFTWARE INTERLOCKS BUILT IN THE BCU ARE VERIFIED BEFORE CHECKING THE SYNCHRONISATION CONDITIONS. FOR DETAILED INTERLOCKS REFER THE RESPECTIVE BAY INTERLOCK LOGIC DIAGRAMS
***
WHEN BOTH VOLTAGES ARE BELOW THE SET THRESHOLD FOR DEAD VOLTS, A TIMER IS STARTED BEFORE GIVING THE CLOSE SIGNAL TO THE CB. THIS TIMER IS CONFIGURABLE IN THE RANGE 0.2 TO 10 Sec.
1
COMMAND TO THE BREAKER WILL BE SUCCESFUL ONLY IF EXTERNAL HARDWIRED INTERLOCKS IN THE CB CLOSING CIRCUIT ARE SATISFIED.
CLIENT ADANI POWER LTD. : 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT PROJECT : MUNDRA SEZ
IMPLEMENTATION OF SYNCHROCHECK IN BCU
AREVA
REV.
SHEET
NEXT SH.
B
081
082
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
IMPLEMENATION OF SYNCHROCHECK FUNCTION IN BCU (TYPICAL FOR ALL BAYS EXCEPT GT BAYS)
CASE -2 DEAD INCOMING VOLTS - LIVE RUNNING VOLTS IMPLEMENTED IN BCU
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
SELECTED RUNNING VOLTS *
RUNNING VOLTS > SELECTED LIVE VOLTS THRESHOLD
DEAD INCOMING VOLTS & LIVE RUNNING VOLTS CONDITIONS SATISFIED?
SELECTED INCOMING VOLTS *
INCOMING VOLTS < SELECTED DEAD VOLTS THRESHOLD
CLOSE REQUEST FROM BCU/HMI/SCADA
SOFTWARE INTERLOCKS BUILT IN RESPECTIVE BCU VERIFIED SUCCESFULLY **
YES TIMER FOR CONFIRMATION (SETTABLE) ***
&
TO CLOSING CIRCUIT
INTLKS IMPLEMENTED THROUGH HARDWIRING IN BAY CNTL & PROT PANEL
NOTE : *
VOLTAGE SELECTION FOR INCOMING AND RUNNING VOLTS SHALL BE AS PER THE SELECTION LOGIC INDICATED IN THE RESPECTIVE BAY INTERLOCK LOGICS.
**
SOFTWARE INTERLOCKS BUILT IN THE BCU ARE VERIFIED BEFORE CHECKING THE SYNCHRONISATION CONDITIONS. FOR DETAILED INTERLOCKS REFER THE RESPECTIVE BAY INTERLOCK LOGIC DIAGRAMS
***
WHEN BOTH VOLTAGES ARE BELOW THE SET THRESHOLD FOR DEAD & LIVE VOLTS, A TIMER IS STARTED BEFORE GIVING THE CLOSE SIGNAL TO THE CB. THIS TIMER IS CONFIGURABLE IN THE RANGE 0.2 TO 10 Sec.
1
COMMAND TO THE BREAKER WILL BE SUCCESFUL ONLY IF EXTERNAL HARDWIRED INTERLOCKS IN THE CB CLOSING CIRCUIT ARE SATISFIED.
CLIENT ADANI POWER LTD. : 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT PROJECT : MUNDRA SEZ
IMPLEMENTATION OF SYNCHROCHECK IN BCU
AREVA
REV.
SHEET
NEXT SH.
B
082
083
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
IMPLEMENATION OF SYNCHROCHECK FUNCTION IN BCU (TYPICAL FOR ALL BAYS EXCEPT GT BAYS)
CASE -3 LIVE INCOMING VOLTS - DEAD RUNNING VOLTS IMPLEMENTED IN BCU
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
SELECTED RUNNING VOLTS *
RUNNING VOLTS < SELECTED DEAD VOLTS THRESHOLD
LIVE INCOMING VOLTS & DEAD RUNNING VOLTS CONDITIONS SATISFIED?
SELECTED INCOMING VOLTS *
INCOMING VOLTS > SELECTED LIVE VOLTS THRESHOLD
CLOSE REQUEST FROM BCU/HMI/SCADA
SOFTWARE INTERLOCKS BUILT IN RESPECTIVE BCU VERIFIED SUCCESFULLY **
YES TIMER FOR CONFIRMATION (SETTABLE) ***
&
TO CLOSING CIRCUIT
INTLKS IMPLEMENTED THROUGH HARDWIRING IN BAY CNTL & PROT PANEL
NOTE : *
VOLTAGE SELECTION FOR INCOMING AND RUNNING VOLTS SHALL BE AS PER THE SELECTION LOGIC INDICATED IN THE RESPECTIVE BAY INTERLOCK LOGICS.
**
SOFTWARE INTERLOCKS BUILT IN THE BCU ARE VERIFIED BEFORE CHECKING THE SYNCHRONISATION CONDITIONS. FOR DETAILED INTERLOCKS REFER THE RESPECTIVE BAY INTERLOCK LOGIC DIAGRAMS
***
WHEN BOTH VOLTAGES ARE BELOW THE SET THRESHOLD FOR DEAD & LIVE VOLTS, A TIMER IS STARTED BEFORE GIVING THE CLOSE SIGNAL TO THE CB. THIS TIMER IS CONFIGURABLE IN THE RANGE 0.2 TO 10 Sec.
1
COMMAND TO THE BREAKER WILL BE SUCCESFUL ONLY IF EXTERNAL HARDWIRED INTERLOCKS IN THE CB CLOSING CIRCUIT ARE SATISFIED.
CLIENT ADANI POWER LTD. : 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT PROJECT : MUNDRA SEZ
IMPLEMENTATION OF SYNCHROCHECK IN BCU
AREVA
REV.
SHEET
NEXT SH.
B
083
084
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
IMPLEMENATION OF SYNCHROCHECK FUNCTION IN BCU (TYPICAL FOR ALL BAYS EXCEPT GT BAYS)
CASE -4 LIVE INCOMING VOLTS - LIVE RUNNING VOLTS
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
IMPLEMENTED IN BCU
SELECTED RUNNING VOLTS *
RUNNING VOLTS > SELECTED LIVE VOLTS THRESHOLD
LIVE INCOMING VOLTS & LIVE RUNNING VOLTS CONDITIONS SATISFIED?
SELECTED INCOMING VOLTS *
INCOMING VOLTS > SELECTED LIVE VOLTS THRESHOLD
CLOSE REQUEST FROM BCU/HMI/SCADA
SOFTWARE INTERLOCKS BUILT IN RESPECTIVE BCU VERIFIED SUCCESFULLY **
YES TIMER FOR CONFIRMATION (SETTABLE) ***
&
TO CLOSING CIRCUIT
INTLKS IMPLEMENTED THROUGH HARDWIRING IN BAY CNTL & PROT PANEL
NOTE : *
VOLTAGE SELECTION FOR INCOMING AND RUNNING VOLTS SHALL BE AS PER THE SELECTION LOGIC INDICATED IN THE RESPECTIVE BAY INTERLOCK LOGICS.
**
SOFTWARE INTERLOCKS BUILT IN THE BCU ARE VERIFIED BEFORE CHECKING THE SYNCHRONISATION CONDITIONS. FOR DETAILED INTERLOCKS REFER THE RESPECTIVE BAY INTERLOCK LOGIC DIAGRAMS
***
WHEN BOTH VOLTAGES ARE BELOW THE SET THRESHOLD FOR DEAD & LIVE VOLTS, A TIMER IS STARTED BEFORE GIVING THE CLOSE SIGNAL TO THE CB. THIS TIMER IS CONFIGURABLE IN THE RANGE 0.2 TO 10 Sec.
1
COMMAND TO THE BREAKER WILL BE SUCCESFUL ONLY IF EXTERNAL HARDWIRED INTERLOCKS IN THE CB CLOSING CIRCUIT ARE SATISFIED.
2
FOR LIVE CONDITIONS OF BOTH THE INCOMING & RUNNING VOLTS, THE FOLLOWING CONDITIONS(CONFIGURED THROUGH SOFTWARE) ARE CHECKED: A. B. C.
DIFFERENCE IN VOLTAGE MAGNITUDES DIFFERENCE IN PHASE ANGLES DIFFERENCE IN FREQUENCIES
CLIENT ADANI POWER LTD. : 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT PROJECT : MUNDRA SEZ
IMPLEMENTATION OF SYNCHROCHECK IN BCU
AREVA
REV.
SHEET
NEXT SH.
B
084
085
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
IMPLEMENATION OF AUTO RECLOSE FUNCTION IN BCU (TYPICAL FOR ALL LINE BAYS)
CLIENT ADANI POWER LTD. : 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT PROJECT : MUNDRA SEZ
IMPLEMENTATION OF AUTORECLOSE FUNCTION IN BCU
AREVA
REV.
SHEET
NEXT SH.
B
085
086
AREVA T&D India Limited
EMI-7604PG754-4-028
DF003
This drawing and design is the property of AREVA T&D and must not be copied or lent without prior permission in writing
IMPLEMENATION OF AUTO RECLOSE FUNCTION IN BCU (TYPICAL FOR ALL TIE BAYS)
CLIENT ADANI POWER LTD. : 400kV SWITCHYARD FOR 2x330MW THERMAL POWER PLANT PROJECT : MUNDRA SEZ
IMPLEMENTATION OF AUTORECLOSE FUNCTION IN BCU