Alcatel-Lucent 7360 INTELLIGENT SERVICES ACCESS MANAGER FX | RELEASE 4.3 PRODUCT INFORMATION
3HH-10116-AAAA-TCZZA Edition 01 Released
Alcatel-Lucent Proprietary This document contains proprietary information of Alcatel-Lucent and is not to be disclosed or used except in accordance with applicable agreements. Copyright 2011 © Alcatel-Lucent. All rights reserved.
Alcatel-Lucent assumes no responsibility for the accuracy of the information presented, which is subject to change without notice. Alcatel, Lucent and the Alcatel-Lucent logo are registered trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. Copyright 2011 Alcatel-Lucent. All rights reserved. Disclaimers
Alcatel-Lucent products are intended for commercial uses. Without the appropriate network design engineering, they must not be sold, licensed or otherwise distributed for use in any hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life-support machines, or weapons systems, in which the failure of products could lead directly to death, personal injury, or severe physical or environmental damage. The customer hereby agrees that the use, sale, license or other distribution of the products for any such application without the prior written consent of Alcatel-Lucent, shall be at the customer's sole risk. The customer hereby agrees to defend and hold Alcatel-Lucent harmless from any claims for loss, cost, damage, expense or liability that may arise out of or in connection with the use, sale, license or other distribution of the products in such applications. This document may contain information regarding the use and installation of non-Alcatel-Lucent products. Please note that this information is provided as a courtesy to assist you. While Alcatel-Lucent tries to ensure that this information accurately reflects information provided by the supplier, please refer to the materials provided with any non-Alcatel-Lucent product and contact the supplier for confirmation. Alcatel-Lucent assumes no responsibility or liability for incorrect or incomplete information provided about non-Alcatel-Lucent products. However, this does not constitute a representation or warranty. The warranties provided for Alcatel-Lucent products, if any, are set forth in contractual documentation entered into by Alcatel-Lucent and its customers. This document was originally written in English. If there is any conflict or inconsistency between the English version and any other version of a document, the English version shall prevail.
When printed by Alcatel-Lucent, this document is printed on recycled paper.
Preface
This preface provides general information about the documentation set for the 7360 Intelligent Services Access Manager FX (7360 ISAM FX).
Scope This documentation set provides information about safety, features and functionality, ordering, hardware installation and maintenance, CLI and TL1 commands, and software upgrade and migration procedures.
Audience This documentation set is intended for planners, administrators, operators, and maintenance personnel involved in installing, upgrading, or maintaining the 7360 ISAM FX.
Prerequisite knowledge The reader must be familiar with general telecommunications principles.
Safety information For ETSI safety information, see the 7360 ISAM FX Safety Manual.
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
iii
Preface
The following are examples of how special information is presented in this document. Danger — Danger indicates that the described activity or situation
may result in serious personal injury or death; for example, high voltage or electric shock hazards. Warning — Warning indicates that the described activity or situation
may, or will, cause equipment damage or serious performance problems. Caution — Caution indicates that the described activity or situation may, or will, cause service interruption.
Note — A note provides information that is, or may be, of special
interest.
Document conventions The following conventions are used in this documentation set.
Acronyms See the glossary included with the System Description for FD 100/320Gbps NT and FX NT for the expansion of acronyms used in this documentation set.
Release notes Be sure to refer to the release notes (such as the Customer Release Notes or Emergency Fix Release Note) issued for software loads of the 7360 ISAM before you install or use the 7360 ISAM FX . The release notes provide important information about the software load.
iv
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Preface
Documents Table 1 lists the documents that make up the 7360 ISAM FX Release 4.3 documentation set. Table 1 7360 ISAM FX Release 4.3 documentation set Title
Description
Part number
CD containing all the documents in the 7360 ISAM FX documentation set (1)
3HH-10103-AAAA
Product Information
Provides general system information for the 7360 ISAM FX
3HH-10116-AAAA-TCZZA
System Description for FD 100/320Gbps NT and FX NT
Provides conceptual information for:
3HH-09811-BAAA-TQZZA
•
Documentation CD 7360 ISAM FX CD General documentation
• Safety Manual
the 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT the 7360 ISAM FX equipped with an FX NT
Provides general safety guidelines when handling, installing, or operating the 7360 ISAM FX equipment
3HH-10126-AAAA-TCZZA
Describes the hardware installation for the 7360 ISAM FX equipment
3HH-10127-AAAA-RJZZA
Describes the TL1 commands and messages for:
3HH-09857-BAAA-TCZZA
Hardware documentation FX Hardware Installation Guide TL1 documentation TL1 Commands and Messages for FD 100/320Gbps NT and FX NT
• •
Operations and Maintenance Using TL1 for FD 100/320Gbps NT and FX NT
the 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT the 7360 ISAM FX equipped with an FX NT
Provides task-oriented procedures using TL1 for operating and maintaining:
• •
3HH-09858-BAAA-TQZZA
the 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT the 7360 ISAM FX equipped with an FX NT
CLI documentation CLI Commands for FD 100/320Gbps NT and FX NT
Describes the CLI commands for:
• •
Operations and Maintenance Using CLI for FD 100/320Gbps NT and FX NT
Provides task-oriented procedures using CLI for operating and maintaining:
• •
3HH-08079-DDAA-TCZZA
the 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT the 7360 ISAM FX equipped with an FX NT 3HH-10104-BAAA-TQZZA
the 7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT the 7360 ISAM FX equipped with an FX NT
IHub System Basics, Management and OAM Guide for FD 100/320Gbps NT and FX NT
Describes the IHub system basics, system management and OAM (Operations and Maintenance)
3HH-10106-AAAA-TQZZA
IHub Interface Guide for FD 100/320Gbps NT and FX NT
Describes the IHub system interfaces
3HH-10107-AAAA-TQZZA
(1 of 2)
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
v
Preface
Title
Description
Part number
IHub QoS Guide for FD 100/320Gbps NT and FX NT
Describes the IHub Quality of Service
3HH-10108-AAAA-TQZZA
IHub Router Configuration and Protocols Guide for FD 100/320Gbps NT and FX NT
Describes the IHub router configuration and router protocols
3HH-10110-AAAA-TQZZA
IHub Services Guide for FD 100/320Gbps NT and FX NT
Describes the IHub services
3HH-10109-AAAA-TQZZA
IHub MPLS Guide for FD 100/320Gbps NT and FX NT
Describes the IHub MPLS services
3HH-10111-AAAA-TQZZA
Software Installation Guide
Describes the software management of the 7302 ISAM, the 7330 ISAM FTTN, the 7356 ISAM FTTB and the 7360 ISAM FX equipment
3HH-07196-AAAA-RJZZA
Software Upgrade and Migration Application Procedures
Provides instructions for using the automated tools for upgrading and migrating the software for the 7302 ISAM, the 7330 ISAM FTTN, the 7356 ISAM FTTB and the 7360 ISAM FX
3HH-08277-AAAA-TCZZA
Software documentation(1)
(2 of 2) Note (1)
vi
Software documentation is not included on the 7360 ISAM documentation CD
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Contents
Preface
iii
Scope ............................................................................................... iii Audience ............................................................................................... iii Prerequisite knowledge ............................................................................... iii Safety information ..................................................................................... iii Document conventions ................................................................................ iv Release notes........................................................................................... iv Documents ............................................................................................... v
1—
System Overview 1.1 1.2 1.3 1.4 1.5 1.6 1.7
2—
Subracks 2.1 2.2 2.3 2.4 2.5
3—
2-1
Introduction .............................................................................. 2-2 General ................................................................................... 2-2 7360 ISAM FX Subracks ................................................................. 2-2 Supported Plug-in Units ................................................................ 2-6 Dummy Front Panels .................................................................... 2-7
Physical Rack Equipment 3.1 3.2
1-1
Introduction .............................................................................. 1-2 System Architecture .................................................................... 1-6 Network Management ................................................................. 1-17 Equipment Management .............................................................. 1-18 Board Capabilities and Dimensioning ............................................... 1-19 NT Redundancy Support............................................................... 1-25 CLEI Codes............................................................................... 1-26
3-1
General ................................................................................... 3-2 Universal Rack ........................................................................... 3-2
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
vii
Contents
3.3 3.4 3.5
4—
Rack Configurations 4.1 4.2
5—
5-1
Introduction .............................................................................. 5-2 SFP Optical Modules .................................................................... 5-2
Board Mnemonics A.1
4-1
General ................................................................................... 4-2 Rack Configurations..................................................................... 4-2
SFP Optical Modules 5.1 5.2
A.
Side Plates ............................................................................... 3-5 Rack Doors ............................................................................... 3-6 Key Locks ................................................................................. 3-7
A-1
Board Mnemonics........................................................................ A-2
Index
viii
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1—
System Overview
1.1 Introduction
1-2
1.2 System Architecture
1-6
1.3 Network Management 1.4 Equipment Management
1-17 1-18
1.5 Board Capabilities and Dimensioning 1.6 NT Redundancy Support 1.7 CLEI Codes
1-19
1-25
1-26
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1-1
1 — System Overview
1.1
Introduction The 7360 ISAM FX is a frame based Multi Service Access Platform, offering high-density fiber connections for multimedia, high-speed internet access, voice and business services.
General Network Topology Figure 1-1 shows the basic network topology. Figure 1-1 General network topology IP Edge Router / BRAS Ethernet Switch xDSL
NSP IP backbone
ISAM
Ethernet
FE/GE
Voice
EMAN
DS1/E1
NSP IP backbone
FE/GE
Video
NSP IP backbone
ISAM ISAM shelf xDSL
xDSL LT
Ethernet Voice
Voice LT
NT
FE/GE/10GE
DS1/E1 ONT/ OMCI ONU GPON
Video
FE/GE/10GE
Eth LT
GPON LT
xDSL/Ethernet
Voice
ONT/ ONU
OAM EPON
EPON LT
ISAM OLT
Note — Possible user interface types are not limited to the types shown on the figure.
1-2
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1 — System Overview
User Side At the user side, each 7360 ISAM FX shelf can terminate:
• Ethernet user interfaces • Passive Optical Network (PON) interfaces It is possible to connect subtending DSLAMs to the FE/GE/10GE links at the user side in:
• cascading mode: a chain of 1 subtending ISAM per ISAM; see Figure 1-2 • star mode: multiple subtending ISAMs per ISAM; see Figure 1-3 • ring mode (except when there is a ring behind a Hub-ISAM); see Figure 1-4. Figure 1-2 Cascading Topology
Cascading up to three levels ISAM ISAM
ISAM
k*FE/GE/10GE k*FE/GE/10GE
EMAN User interfaces
User interfaces
User interfaces
Figure 1-3 Star Topology ISAM
ISAM
k*FE/GE/10GE
EMAN User interfaces ISAM
User interfaces
k*FE/GE/10GE User interfaces
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1-3
1 — System Overview Figure 1-4 Ring Topology ISAM User interfaces
k*FE/GE/10GE ISAM
ISAM User interfaces
EMAN
k*FE/GE/10GE
ISAM
User interfaces
User interfaces k*FE/GE/10GE
Network Side At the network side, the 7360 ISAM terminates FE, GE, or 10GE links. The following configurations are possible:
• Connected to one or more Ethernet Switches The Ethernet links can be connected to one or more Ethernet Switches. These Ethernet Switches forward the frames over the Ethernet based aggregation access network until they reach the IP Edge Router or BRAS of the corresponding Network Service Provider (NSP). At the IP Edge Router or BRAS, the frames enter the IP backbone of the NSP. • More than one FE/GE/10GE link (link aggregation) In case of more than one link, Ethernet link aggregation is used. • Directly connected to an IP Edge Router The 7360 ISAM FX can be connected directly to the IP Edge Router or BRAS. The Ethernet aggregation network is reduced to one or more parallel Ethernet links. • Can also be connected to a Multi-protocol Label Switching (MPLS) network.
1-4
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1 — System Overview Figure 1-5 Network Connections IP Edge Router / BRAS Ethernet Switch ISAM User interfaces
NSP IP backbone
m x FE/GE/10GE
EMAN
FE/GE
NSP IP backbone
n x FE/GE/10GE
NSP IP backbone
ISAM User interfaces NSP IP backbone FE/GE
Note — A link is a term which is used to refer to the physical layer of an interface of the 7360 ISAM FX, for example, an Ethernet link.
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1-5
1 — System Overview
1.2
System Architecture
Functional Decomposition The ISAM is built as a typical multiplexer which can be equipped with the following main boards:
• • • • •
a Network Termination (NT) board (optionally 1+1 redundant) a NT Input/Output board (optional) a set of Ethernet Line Termination (LT) boards implementing the user interfaces. Gigabit Passive Optical Network (GPON) LT boards Ethernet Passive Optical Network (EPON) LT boards Figure 1-6 ISAM Decomposition ISAM
NT
LT
…
NTIO
LT-applique
The ISAM’s management plane, control plane, and most of the data plane is realized on the NT board and on the LT boards. Figure 1-7 ISAM System Decomposition
NT
LT
iHub LT-Control
iHub control
Switch/Router
System control
Transport
IWF
Data plane Control plane
1-6
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1 — System Overview
FX NT Board
The FX NT board consist of an IHub subsystem and a System Control subsystem.
• The IHub subsystem has enhanced L2 functionality (VPLS based) and L3 functionality (VPRN based) and consists of a 10-Gigabit-Ethernet switch/router device, and IHub control software (SW). • The System Control subsystem implements the management plane of the system (both the NT board and the LT boards) and part of the control plane (subscriber management in particular). The System Control consists of SW running on a powerful general purpose processor. It shares this processor with the IHub control SW (on a separate processor core). Line Termination (LT) Boards
Line Termination (LT) boards are built from an InterWorking Function (IWF), a Transport subsystem and an LT-Control subsystem.
• The transport subsystem terminates the physical layer of the subscriber interfaces. It varies with the type of access technology used (Ethernet,...). • The IWF processes the packets in the fast path. It is capable of handling frames at L2 (basically bridging) and L3 (basically IP forwarding), including sophisticated filtering and traffic management, all at the line rate of the transport medium. • The LT-Control subsystem takes care of the slow path control plane and internal Operations And Maintenance applications. GPON LT Boards
The GPON functionality of the ISAM extends the system boundaries via up to 128 Optical Network Terminations (ONTs) over a fiber plant that can reach 10s of kilometers out from the GPON LT boards located in an ISAM shelf. These GPON LT boards provide the physical interfaces from the ISAM shelf towards the Customer Premises Equipment, that is, the ONTs. EPON LT Boards
The EPON functionality of the ISAM extends the system boundaries via up to 64 Optical Network Terminations (ONTs) over a fiber plant that can reach 10s of kilometers out from the EPON LT boards located in an ISAM shelf. These EPON LT boards provide the physical interfaces from the ISAM shelf towards the Customer Premises Equipment, that is, the ONTs.
Physical Decomposition Figure 1-8 shows the general functional architecture of the ISAM, from the viewpoint of its forwarding capabilities.
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1-7
1 — System Overview Figure 1-8 High-level ISAM Architecture Network links | Subtending links | User links
E M A N
Ethernet
IHub router
2
-
n
IWF
EPS
LT control
IHub control
NTIO
Transport
CPE
GPON
ONT
EPON
ONT
LT
System control
NT
An ISAM shelf consists out of the following board types:
• NT board • LT boards NT Board
Provisions are made to equip two NT boards in the shelf. These NT boards can act as an active / stand-by pair for all functions. The following NT boards are supported in FX equipment:
• FANT-F (480 Gbps NT board): This NT board with integrated IHub subsystem provides the following links on the front panel:
• One electrical RJ45 interface: This port supports 10/100/1000Base-T
• Four 10GE SFPplus port: These ports can work both in 1 GE mode (with standard SFP optics) and in 10 GE mode (with SFPplus optics). LT Boards
The LT boards consists of a IWF, the transport termination and the LT control. The LT boards, also known as Line Interface Modules (LIMs), use a different interworking function between the user side and the Ethernet network side, depending on the board type. Table 1-1 shows the supported LT boards with their physical interface types, density (that is, number of lines per board) and Interworking function (IWF) capability. Table 1-1 Supported LT Boards LT Board
Physical Interfaces
Overlay
Density
NT Interface
IWF
NELT-B
Ethernet
-
36
10 GE
L3
(2)
(1 of 2)
1-8
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1 — System Overview
LT Board
Physical Interfaces
Overlay
Density
NT Interface
IWF
NGLT-A
GPON
-
8
10 GE
L3
FPLT-A
EPON
-
8
10 GE
L2(1)
(2)(3)
(2 of 2) Notes (1) L2: IWF function capability on Layer 2. For an overview of the IWF capabilities, refer to section 1.5 (2) L3: IWF function capability on Layer 2 and Layer 3. For an overview of the IWF capabilities, refer to section 1.5 (3) Not all L3 features are supported in these ports, see Table 1-13
GFC Board
The General Facilities Card (GFC) provides connections for external power, circuit breakers for system protection, visual indications for power availability and collection and cascading of external alarms. Note — These boards are only used on the FX-8 and FX-4 subracks.
NTIO Board
The NTIO board plays the role of an applique to either the single NT board, or to both NT boards, depending on the NT redundancy configuration. It allows to decouple NT equipment protection from up-link protection in case of a redundant NT pair. In case the active NT fails, traffic on the NTIO external links will be switched automatically to and from the stand-by NT. Table 1-2 shows the supported NT I/O boards. Table 1-2 NT I/O Boards Board
Interfaces
FNIO-B
Eight additional external Ethernet interfaces:
•
eight optical 100/1000Base-FX
Eight additional external Ethernet interfaces:
• •
four optical 100/1000Base-FX four combo uplink ports, which can be configured to optical uplink ports (SFP ports, 100Base-FX, 1000Base-FX) or electrical uplink ports ( RJ45, 10/100/1000BASE-T)
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1-9
1 — System Overview
Port mapping
The tables below list the port mapping for 7360 ISAM FX, that is, the mapping between the logical port numbers as used in the ISAM and the physical port numbers as visible on the equipment itself (frontplate numbering).
• Table 1-3 lists the different mapped items. • Table 1-4 lists the port mapping for the FANT-F board in a 7360 ISAM FX-16 • • • • •
subrack. Table 1-5 lists the port mapping for the FANT-F board in a 7360 ISAM FX-16 in dual NT + NTIO subrack mode for FNIO-B. Table 1-6 lists the port mapping for the FANT-F board in a 7360 ISAM FX-8 subrack. Table 1-7 lists the port mapping for the FANT-F board in a 7360 ISAM FX-8 in dual NT + NTIO subrack mode for FNIO-B. Table 1-8 lists the port mapping for the FANT-F board in a 7360 ISAM FX-4 subrack. Table 1-9 lists the port mapping for the FANT-F board in a 7360 ISAM FX-4 in dual NT + NTIO subrack mode for FNIO-B. Table 1-3 Mapped Items Item
Description
Physical Port Number
The physical switch device port number.
Logical Port Number
The port number as denoted in the SNMP management interface
LT port number (index based)
For internal LT ports, the index of the LT in the main subrack that corresponds to this port (for local LTs only)
Faceplate port number
For external ports, the manner in which this port is identified at the faceplate of the board.
Port state / configurability
For NTIO ports, the manner in which this port can be configured:
• •
UP for uplinks/subtending/user links DOWN for internal LT links
and
• •
FIXED for fixed configuration (UP or DOWN) CONF for configurable configuration (UP or DOWN)
Table 1-4 FANT-F in 7360 ISAM FX-16 Physical Port Number
Logical Port Number
LT Slot Number (index based)
10
15
1
12
16
2
16
17
3
18
18
4
Faceplate Port Number
Interface
(1 of 2)
1-10
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1 — System Overview
Physical Port Number
Logical Port Number
LT Slot Number (index based)
Faceplate Port Number
Interface
32
19
5
34
20
6
41
21
7
43
22
8
45
23
9
37
24
10
22
25
11
8
26
12
39
27
13
28
28
14
20
29
15
14
30
16
2
5
1 (NT-A)
RJ45
4
6
X1 (NT-A)
SFP+
5
7
X2 (NT-A)
SFP+
6
8
X3 (NT-A)
SFP+
7
9
X4 (NT-A)
SFP+
3
3
IEEE1588 (NT-A)
2
10
1 (NT-B)
RJ45
4
11
X1 (NT-B)
SFP+
5
12
X2 (NT-B)
SFP+
6
13
X3 (NT-B)
SFP+
7
14
X4 (NT-B)
SFP+
3
4
IEEE1588 (NT-B)
(2 of 2)
Table 1-5 FANT-F + FNIO-B in 7360 ISAM FX-16 Physical Port Number
Logical Port Number
LT Slot Number (index based)
10
15
1
12
16
2
16
17
3
18
18
4
Faceplate Port Number
Interface
FNIO-B Faceplate Port Number
Port State / Configurability
(1 of 2)
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1-11
1 — System Overview
Physical Port Number
Logical Port Number
LT Slot Number (index based)
Faceplate Port Number
Interface
32
19
5
34
20
6
41
21
7
43
22
8
45
23
9
37
24
10
22
25
11
8
26
12
39
27
13
28
28
14
20
29
15
14
30
16
47
31
as on NTIO
48
32
51
FNIO-B Faceplate Port Number
Port State / Configurability
SFP
1 (SFP)
UP, FIXED
as on NTIO
SFP
2 (SFP)
UP, FIXED
33
as on NTIO
SFP
3 (SFP)
UP, FIXED
52
34
as on NTIO
SFP
4 (SFP)
UP, FIXED
30
35
as on NTIO
SFP or RJ45
5 (Combo)
UP, FIXED
31
36
as on NTIO
SFP or RJ45
6 (Combo)
UP, FIXED
49
37
as on NTIO
SFP or RJ45
7 (Combo)
UP, FIXED
50
38
as on NTIO
SFP or RJ45
8 (Combo)
UP, FIXED
2
5
1 (NT-A)
RJ45
4
6
X1 (NT-A)
SFP+
5
7
X2 (NT-A)
SFP+
6
8
X3 (NT-A)
SFP+
7
9
X4 (NT-A)
SFP+
3
3
IEEE1588 (NT-A)
2
10
1 (NT-B)
RJ45
4
11
X1 (NT-B)
SFP+
5
12
X2 (NT-B)
SFP+
6
13
X3 (NT-B)
SFP+
7
14
X4 (NT-B)
SFP+
3
4
IEEE1588 (NT-B)
(2 of 2)
1-12
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1 — System Overview Table 1-6 FANT-F in 7360 ISAM FX-8 Physical Port Number
Logical Port Number
LT Slot Number (index based)
Faceplate Port Number
Interface
59
15
1
47
16
2
28
17
3
8
18
4
51
19
5
36
20
6
24
21
7
16
22
8
2
5
1 (NT-A)
RJ45
4
6
X1 (NT-A)
SFP+
5
7
X2 (NT-A)
SFP+
6
8
X3 (NT-A)
SFP+
7
9
X4 (NT-A)
SFP+
3
3
IEEE1588 (NT-A)
2
10
1 (NT-B)
RJ45
4
11
X1 (NT-B)
SFP+
5
12
X2 (NT-B)
SFP+
6
13
X3 (NT-B)
SFP+
7
14
X4 (NT-B)
SFP+
3
4
IEEE1588 (NT-B)
Table 1-7 FANT-F + FNIO-B in 7360 ISAM FX-8 Physical Port Number
Logical Port Number
LT Slot Number (index based)
59
15
1
47
16
2
28
17
3
8
18
4
51
19
5
36
20
6
Faceplate Port Number
Interface
FNIO-B Faceplate Port Number
Port State / Configurability
(1 of 2)
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1-13
1 — System Overview
Physical Port Number
Logical Port Number
LT Slot Number (index based)
Faceplate Port Number
Interface
24
21
7
16
22
8
63
23
as on NTIO
64
24
14
FNIO-B Faceplate Port Number
Port State / Configurability
SFP
1 (SFP)
UP, FIXED
as on NTIO
SFP
2 (SFP)
UP, FIXED
25
as on NTIO
SFP
3 (SFP)
UP, FIXED
15
26
as on NTIO
SFP
4 (SFP)
UP, FIXED
40
27
as on NTIO
SFP or RJ45
5 (Combo)
UP, FIXED
41
28
as on NTIO
SFP or RJ45
6 (Combo)
UP, FIXED
12
29
as on NTIO
SFP or RJ45
7 (Combo)
UP, FIXED
13
30
as on NTIO
SFP or RJ45
8 (Combo)
UP, FIXED
2
5
1 (NT-A)
RJ45
4
6
X1 (NT-A)
SFP+
5
7
X2 (NT-A)
SFP+
6
8
X3 (NT-A)
SFP+
7
9
X4 (NT-A)
SFP+
3
3
IEEE1588 (NT-A)
2
10
1 (NT-B)
RJ45
4
11
X1 (NT-B)
SFP+
5
12
X2 (NT-B)
SFP+
6
13
X3 (NT-B)
SFP+
7
14
X4 (NT-B)
SFP+
3
4
IEEE1588 (NT-B)
(2 of 2)
Table 1-8 FANT-F in 7360 ISAM FX-4 Physical Port Number
Logical Port Number
LT Slot Number (index based)
Faceplate Port Number
Interface
27
15
1
23
16
2
12
17
3
8
18
4
2
5
1 (NT-A)
RJ45
4
6
X1 (NT-A)
SFP+
(1 of 2)
1-14
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1 — System Overview
Physical Port Number
Logical Port Number
5
LT Slot Number (index based)
Faceplate Port Number
Interface
7
X2 (NT-A)
SFP+
6
8
X3 (NT-A)
SFP+
7
9
X4 (NT-A)
SFP+
3
3
IEEE1588 (NT-A)
2
10
1 (NT-B)
RJ45
4
11
X1 (NT-B)
SFP+
5
12
X2 (NT-B)
SFP+
6
13
X3 (NT-B)
SFP+
7
14
X4 (NT-B)
SFP+
3
4
IEEE1588 (NT-B)
(2 of 2)
Table 1-9 FANT-F + FNIO-B in 7360 ISAM FX-4 Physical Port Number
Logical Port Number
LT Slot Number (index based)
Faceplate Port Number
Interface
27
15
1
23
16
2
12
17
3
8
18
4
31
19
as on NTIO
32
20
35
FNIO-B Faceplate Port Number
Port State / Configurability
SFP
1 (SFP)
UP, FIXED
as on NTIO
SFP
2 (SFP)
UP, FIXED
21
as on NTIO
SFP
3 (SFP)
UP, FIXED
36
22
as on NTIO
SFP
4 (SFP)
UP, FIXED
20
23
as on NTIO
SFP or RJ45
5 (Combo)
UP, FIXED
21
24
as on NTIO
SFP or RJ45
6 (Combo)
UP, FIXED
33
25
as on NTIO
SFP or RJ45
7 (Combo)
UP, FIXED
34
26
as on NTIO
SFP or RJ45
8 (Combo)
UP, FIXED
2
5
1 (NT-A)
RJ45
4
6
X1 (NT-A)
SFP+
5
7
X2 (NT-A)
SFP+
6
8
X3 (NT-A)
SFP+
7
9
X4 (NT-A)
SFP+
3
3
IEEE1588 (NT-A)
(1 of 2)
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1-15
1 — System Overview
Physical Port Number
Logical Port Number
2
LT Slot Number (index based)
Faceplate Port Number
Interface
10
1 (NT-B)
RJ45
4
11
X1 (NT-B)
SFP+
5
12
X2 (NT-B)
SFP+
6
13
X3 (NT-B)
SFP+
7
14
X4 (NT-B)
SFP+
3
4
IEEE1588 (NT-B)
FNIO-B Faceplate Port Number
Port State / Configurability
(2 of 2)
IHub The IHub provides L2 bridging (based on VPLS) and IP routing (based on VPRN). It has at least 28 ports with a various specialization: A number of ports are used to make a connection at 1 Gbps or at 2.5 Gbps or at 10 Gbps to an LT local in the shelf (one IHub link per LT). The actual connection speed depends on the LT capabilities; see Table 1-1. The FE/GE ports, which are not used for connecting LT boards (local or remote), and the 10GE ports, are available as network interfaces, as interfaces to subtended DSLAM systems, or for connecting directly to users. These links serve network links, subtending links, or user links respectively. Use of these ports is possible either through:
• Link interfaces which are physically located on an NTIO board, connected via bi-directional point-to-point high-speed tracks on the back-panel to both NT boards. These interfaces can also be used as electrical FE, electrical GE or optical GE, optical 10GE interfaces, for uplink, subtending or user links (depending on the NTIO board capabilities and software support). The NTIO board contains an NT equipment protection switch per external link interface. So link protection and NT equipment protection can be performed independently from each other for links terminated on the NTIO. • Link interfaces that are physically located on the NT board itself, as electrical FE interfaces, electrical GE interfaces, optical GE interfaces, and optical 10 GE interfaces, for uplink, subtending or user links.
1-16
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1 — System Overview
1.3
Network Management Figure 1-9 shows how the 7360 ISAM FX can be managed in a network. Figure 1-9 7360 ISAM FX Network Management Remote CT CLI (via Telnet) TL1 (via UDP-login)
EMS
CT
ISAM
RS232
LIM IACM
EMAN
LIM xHub LIM Network Ports Management Flow to cascaded ISAM
The remote Craft Terminal (CT) uses TL1 commands or Command Line Interface (CLI) commands. TL1 is used for pre-provisioning of the NT board. CLI is used to manage both the xHub subsystem and the IACM. Figure 1-10 shows the management topology for the 7360 ISAM FX. Figure 1-10 7360 ISAM FX Management Topology EMS (e.g. AMS 5520)
SNMPv2 or SNMPv3
SNMP agent
TL1 Gateway
UDP
TL1 Terminal
SSH
Telnet
TL1 agent
TL1 CT
CLI Terminal
RS232
SSH
CLI agent
Telnet
CLI CT
Debug Terminal
RS232
UDP
Debug agent
ISAM
The NT Controller and the xHub subsystem each contain a separate SNMP agent. These can be managed via an Element Management Station (EMS), such as the Alcatel-Lucent 5520 AMS. It is also possible to use local TL1 or CLI craft terminal on the NT board to manage the LTs. Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1-17
1 — System Overview
An integrated CLI approach is implemented on the NT board using an CLI agent. This agent implements CLI commands for the NT Controller / LIMs and the xHub subsystem. However, there is no semantic integration. Table 1-10 shows an overview of the involved managers. Table 1-10 Manager Overview Type
Description
EMS
Element Management System (EMS) based on SNMP. The Alcatel-Lucent WorkStation (5520 AMS) is commonly used.
CT
Craft Terminal using TL1 commands or Command Line Interface (CLI) commands.
Note 1 — External OAM VLAN:
The IHub subsystem supports in-band management. This happens through a dedicated VLAN, which must be configured (if different than 4093) on both the IHub subsystem as on the NT. Note 2 — VLAN 4094 and VLAN range 4088 and 4092 are reserved
for internal use.
1.4
Equipment Management The NE equipment practice type does not have to be explicitly planned by the operator, but is auto-planned by the NT at startup, depending on the detected type. At the same time, the NT will autoplan the maximum number of racks supported by this equipment practice. The following ISAM type is defined:
• LNWW: Large New Equipment Practise Worldwide market (6 racks, 4 subracks per rack) Subracks are automatically planned upon detection. The operator can control the administrative state of a subrack (lock/unlock). The NE manages different types of boards. A complete overview of all supported board types in each type of subrack is given in the chapter “Subracks”. Board planning is supported for all types of boards, including the appliques. For LSMs, the operator can control the administrative state (lock/unlock).
Central Office Equipment management Central Office equipment only supports configurations consisting of a single rack/subrack.
ONT Management For more information on the ONT management, see the System Description for FD 100/320Gbps NT and FX NT document.
1-18
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1 — System Overview
1.5
Board Capabilities and Dimensioning This section provides an overview of:
• • • • • • •
dimensioning information for the NT boards; see Table 1-11 SyncE support on NT boards and NTIO boards; see Table 1-12 the IWF capabilities of the LT boards per forwarding type; see Table 1-13 Ethernet frame size; see Table 1-14 dimensioning information of the LT boards per forwarding type; see Table 1-15 GPON-specific dimensioning; see Table 1-16 EPON-specific dimensioning; see Table 1-17
NT Board Dimensioning Table 1-11 shows the dimensioning for the different NT board and their variants. Table 1-11 NT Board Dimensioning Description
FANT-F AC
Throughput
480 Gbps
Maximum number of MAC addresses (FDB)(1)
128 k
Maximum number of IP interfaces
512
ARP table size
16 k
Maximum number of IP routes: FIB
16 k
RIB
16 k
Maximum number of L2 filters
512(2)
Maximum number of L3 filters
512
Maximum number of VLAN Maximum number of cross-connect L2 frame size (in bytes) External interfaces
4k 4k 480 Gbps 1 x El. GE 4 x 1/10 GE
BITS in/out ports
1/1
SyncE input/output
4/4
Note (1) (2)
A number of MAC addresses are always used by the system for internal purposes. The same resource is shared for L2 filters and L3 filters. So, the maximum cannot be obtained for both at the same time.
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1-19
1 — System Overview
SyncE Support Table 1-12 indicates the port applicability of the Synchronous Ethernet NTR functionality for clock extraction (in) and generation (out). Table 1-12 Faceplate port applicability for Synchronous Ethernet Board
Port
SyncE In Support
SyncE Out Support
FANT-F
X1
1GE and 10GE
1GE and 10GE
X2
1GE and 10GE
1GE and 10GE
X3
1GE and 10GE
1GE and 10GE
X4
1GE and 10GE
1GE and 10GE
1
-
1GE
2
-
1GE
3
-
1GE
4
-
1GE
5
-
1GE
6
-
1GE
7
-
1GE
8
-
1GE
FNIO-B
1-20
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1 — System Overview
IWF Capabilities Table 1-13 provides an overview of the IWF capabilities of the LT boards. Refer to Table 1-1 for an overview of the supported LT boards. Table 1-13 IWF Capabilities Feature
L3
L3 GPON
L3 EPON
NELT-B UNI
NNI
ATM AAL5 encapsulation type LLC/SNAP bridged (IPoE and PPPoE)
Y
-
-
-
-
LLC/SNAP routed (IPoA)
Y
-
-
-
-
LLC/NLPid (PPPoA)
Y
-
-
-
-
VC Mux Bridged (IPoE and PPPoE)
Y
-
-
-
-
VC Mux Routed (IPoA)
Y
-
-
-
-
VC Mux PPPoA (PPPoA)
Y
-
-
-
-
Autodetect IP (between LLC/SNAP bridged and routed)
Y
-
-
-
-
Autodetect PPP (between LLC/SNAP bridged, VC Mux Bridged and LLC-NLPID, VC Mux PPPoA)
Y
-
-
-
-
Autodetect IP+PPP
Y
-
-
-
-
Autodetect PPPoA (between LLC-NLPID and VC Mux PPPoA)
Y
-
-
-
-
Reception of untagged packets
Y
Y
-
Y
Y
Reception of combination of untagged and priority tagged packets
Y
Y
-
Y
Y
Reception of single tagged packets
Y
Y
Y
Y
Y
Reception of combination of untagged, priority tagged, single tagged packets
Y
Y
-
Y
Y
Port Based Default VLAN for untagged / priority tagged (if applicable) packets
Y
Y
-
Y
Y
Port and Protocol Based default VLAN for untagged / priority tagged packets of the IpoE Protocols
Y
Y
-
Y
Y
Port and Protocol Based default VLAN for untagged / priority tagged packets of the PPPoE Protocols
Y
Y
-
Y
Y
Priority Bit Remarking and Mapping table for tagged / priority tagged packets
Y
Y
Y
Y
Y
RB mode: Protocol Filter (set of Ethertypes) for upstream traffic in VLANs in (PPPoE and IpoE)
Y
Y
Y
Y
Y
RB mode Ethernet packet types: Ethernet II Encap on Ethernet
Y
Y
Y
Y
Y
Encapsulation autodetect
Bridged Encapsulation Ethernet Packet formats
Packet processing
L2 Forwarding
(1 of 2)
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1-21
1 — System Overview
Feature
L3
L3 GPON
L3 EPON
NELT-B UNI
NNI
RB mode Ethernet packet types: LLC/SNAP on Ethernet
Y
Y
Y
Y
Y
CC Mode: transparently pass all encapsulations (e.g. PPPoE and IpoE)
Y
Y
Y
Y
Y
CC Mode: Protocol Filter
Y
Y
-
Y
-
CC Mode: IPoA to IPoE CC
Y
-
-
-
-
VLAN stacking (S-VLAN CC and S-VLAN / C-VLAN CC)
Y
Y
Y
Y
Y
VLAN stacking (S-VLAN / C-VLAN Residential Bridge)
-
-
Y
-
Y
QoS-aware CC
Y
-
-
-
-
ARP: enabling/disabling broadcast
Y
Y
Y
Y
-
802.1X authentication
Y
Y
-
Y
-
DHCP option 82 insertion
Y
Y
Y
Y
-
PPPoE relay tag
Y
Y
Y
Y
-
PPPoA-PPPoE relay
Y
-
-
-
-
Multicast services
Y
Y
Y
Y
-
IPoE
Y
Y
-
Y
-
IPoA
Y
Y
-
Y
-
VLAN termination (at network side), forwarding at Layer 3
Y
Y
-
Y
Y
Y
-
-
Y
-
Y
-
L2 Forwarding user access protocols
L3 Forwarding
L3 Forwarding user access protocols 802.1X authentication ARP proxy user side for IPoE
Y
Y
Y(1)
DHCP relay
Y
-
-
Y
-
Y
Y
Y
Y
Y
Y(2)
Y
-
Y
Y
Y
Y
Y
Y
-
QoS CAC profile Association of QOS profiles to ports Association of QOS profiles to port-VLAN associations (2 of 2) Note (1) (2)
ARP relay only Support policing on bridge port on L2
Ethernet Frame Size Table 1-14 indicates the supported Ethernet frame size for the different line boards..
1-22
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1 — System Overview Table 1-14 Ethernet Frame Size for different LT boards LT Board
Encapsulation
Frame Size (bytes)
P2P Eth
NELT-B UNI (with FCS)
1976
NELT-B NNI (with FCS)
2048
OLT
NGLT-A (with FCS)
2000
OLT
FPLT-A (with FCS)
2000
Dimensioning of the LT Boards Table 1-15 provides dimensioning information of the LT boards. Refer to Table 1-1 for an overview of the supported LT boards. Table 1-15 Dimensioning Information Feature
L3
L3 GPON
L3 EPON
NELT-B UNI
NNI
General Maximum number of PONs
-
8
8
-
-
Maximum number of UNIs
-
4096
4096
-
-
Maximum number of FE ports per board
-
-
-
36
36
Maximum number of GE ports per board
-
-
-
36
36
Maximum number of UNI port type (FE) per board
-
-
-
36
-
Maximum number of UNI port type (GE) per board
-
-
-
36
-
Maximum number of NNI port type (FE) per board
-
-
-
-
36
Maximum number of NNI port type (GE) per board
-
-
-
-
36
Maximum number of CC VLAN
768
11520
7680
4608
4608
Maximum number of RB VLAN
768
1296
1296
1296
1296
Maximum number of VLAN per PVC
16
8
768
-
-
Maximum number of port-VLAN associations per LT
384
11520
11776
-
-
Maximum number of VLAN port per UNI (FE/GE)
-
-
-
8
-
Maximum number of VLAN port per NNI (FE/GE)
-
-
-
-
256
Maximum number of VLAN port per board (UNI)
-
-
-
144
-
Maximum number of VLAN port per board (NNI)
-
-
-
-
4608
64
64
8192
-
-
Maximum number of MAC addresses per UNI
-
-
-
64
-
Maximum number of MAC addresses per NNI
-
-
-
-
3072
1024
16 K(2)
16 K
2304
32768
Maximum number of MAC addresses per VLAN port
Maximum number of MAC addresses per board (including static) (1 of 2)
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1-23
1 — System Overview
Feature
L3
L3 GPON
L3 EPON
384
8K
Average number of IPv4 subnets or addresses per board (=Average IP anti-spoofing entries, full/32 IP address or subnet, per board
-
Maximum number of IPv4 hosts per board
NELT-B UNI
NNI
7680
-
-
-
-
288
0
-
-
-
288
0
Maximum number of IPv6 subnets or addresses per UNI
-
-
-
16
0
Maximum number of IPv6 subnets or addresses per VLAN port
-
-
-
4
0
Maximum number of IPv6 host addresses per board
-
-
-
288
0
128
NA
NA
-
-
Maximum number of simultaneous multicast channels per board
1024
1024
1024
1024
1024
Maximum number of multicast groups per user
100
100
100
100
1024
Maximum number of multicast VLANs
128
128
64
-
-
Maximum number of 802.1x sessions per PON
-
288
-
-
-
Maximum number of 802.1x sessions per UNI
-
-
-
1
-
Maximum number of 802.1x sessions per board
-
2304
-
36
-
Maximum number of user IP addresses per board (including static)
Maximum number of VRFs per board Multicast Dimensioning
802.1x
(2 of 2) Notes (1) Due to thermal restrictions (2) A few MAC addresses are used by the system for internal purposes.
ISAM OLT Service and System Capacity Service and system capacity
Table 1-16 provides specific dimensioning information of the GPON LT boards. Table 1-16 GPON-specific Dimensioning Information
1-24
Feature
L3 GPON
Maximum number of ONT per PON
128
Maximum number of UNIs per PON
512
Maximum number of TCONTs per PON
1024
Maximum number of GEM ports per PON
2048
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1 — System Overview
ISAM OLT performance and distance
The ISAM OLT provides performance and distance capacity of 2.488 Gb/s downstream and 1.244 Gb/s upstream, within a 40 km span, for all NGLT boards. The optical link budget is defined by both loss and bandwidth characteristics. The loss characteristic is determined by the difference between the optical transmitter and optical receiver for each direction, and is typically 28 dB. The bandwidth characteristic is determined by the maximum link distance parameter of each OLT and ONT transmitter specification, and is limited by the smaller of the upstream and downstream values. ISAM OLT connection capacities
The ISAM OLT can accommodate a maximum of 16 NGLT boards. Each NGLT board provides eight ports.
EPON Service and System Capacity Table 1-17 provides specific dimensioning information of the EPON LT boards. Table 1-17 EPON-specific Dimensioning Information
1.6
Feature
L3 EPON
Maximum number of ONT per PON
64
Maximum number of ONT per EPON LT board
512
Maximum number of ONTs per system
8192
Maximum number of LLIDs per ONT
1
Maximum number of UNIs per PON
512
Maximum number of UNIs per LT board
4096
Maximum number of UNIs per system
26214
NT Redundancy Support Four levels of redundancy can be identified:
• • • •
Link redundancy Equipment redundancy Subscriber Line redundancy Application redundancy
NT redundancy will implement the Link Redundancy and Equipment Redundancy in a decoupled architecture. This results in the following redundancy cases:
• Only link protection: single NT, active-standby or load-sharing uplinks. • Combined NT and link protection, no NTIO: dual active/standby NT, with direct uplink or link set. Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1-25
1 — System Overview
• Decoupled NT and link protection, single NTIO: dual active/standby NT, NTIO board with link switches. • NT protection, passive link protection, no NTIO: single, active-standby or load sharing uplinks. • Subtending system protection. Table 1-18 shows which hardware modules are ready for NT redundancy support. Table 1-18 NT Redundancy Support Ready Hardware Modules Type
Module
Subrack
FX-16 FX-8 FX-4
NT boards
FANT-F
NTIO boards
FNIO-B
LT boards
FPLT-A NELT-B NGLT-A
1.7
CLEI Codes Table 1-19 lists the boards and fan units for which CLEI codes are available. Caution — The CLEI code changes whenever an item change (that is, an adaptation to a board) occurs.
The latest status of these CLEI codes is always available on the following website: https://codecenter.commonlanguage.com/applogin.asp?app=clei_inq uiry An account is required before the CLEI database can be accessed. Table 1-19 CLEI codes Mnemonic
Variant
CLEI code
CPR
Bar code
AFAN-H
3EC 37533 NB
VAUCAE2KAA
070LXX
154967
FANT-F
3FE 53701 AC
VAUKAKG6AA
072BWS
179981
FNIO-B
3FE 54057 AA
VAI2AHNNAA
072CUP
181294
NELT-B
3FE 62543 AA
VAUCAJ36AA
072AEY
177909
NGLT-A
3FE 64279 AA
VAI2AFHDAA
070YVT
175498
(1 of 2)
1-26
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
1 — System Overview
Mnemonic
Variant
CLEI code
CPR
Bar code
NFXS-E
3FE 64936 AA
VAM9F10DRA
214460
462367
NGFC-E
3FE 64985 AA
VAUCAJ76AA
072AXH
178685
NFXS-F
3FE 64991 AA
VAMVV10KRA
214392
462173
NGFC-F
3FE 64993 AA
VAUCAJ66AA
072ARH
178373
AFAN-X
3FE 64994 AA
VAUCAJ56AA
072ARC
178361
AFAN-E
3FE 65060 AA
VAUCAJ86AA
072AXJ
178692
NFXS-D
3FE 65209 AA
VAM9G10DRA
214458
462357
(2 of 2)
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
1-27
1 — System Overview
1-28
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
2—
Subracks
2.1 Introduction 2.2 General
2-2
2-2
2.3 7360 ISAM FX Subracks 2.4 Supported Plug-in Units 2.5 Dummy Front Panels
2-2 2-6 2-7
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
2-1
2 — Subracks
2.1
Introduction This chapter describes the different 7360 ISAM FX subracks supported for the European Telecommunication Standard Institute (ETSI) market.
2.2
General The modular organization of the ISAM system allows a wide range of physical size and traffic capacity options. The basic building blocks of the ISAM system are the subracks or shelves(*). (*): Both names are used for the same item. The ISAM R 4.x is a one-subrack system. Daisy-chaining multiple subracks via extender boards is not supported. Multiple collocated subracks can be cascaded via the standard Fast Ethernet (FE)/Gigabit Ethernet (GE)/10Gigabit Ethernet (10GE) subtending links. In such a configuration, each subrack operates and is managed as a separate system.
2.3
7360 ISAM FX Subracks
Subrack Types Table 2-1 lists the 7360 ISAM FX subracks supported in this release. Table 2-1 7360 ISAM FX Subracks Item
7360 ISAM FX Subracks FX-16
FX-8
FX-4
3FE 65209 AA
3FE64936 AA
3FE-64991 AA
NFXS-D
NFXS-E
NFXS-F
Width
529
482.5
482.5
Height
622.5
355
222
Depth
max. 280
278.3
278.3
ETSI racks
Y
Y(1)
Y(1)
19” racks
N
Y
Y
Code Mnemonic Dimensions (in mm)
Can be mounted in:
Notes (1) Adapter brackets must be used
• Figure 2-1 shows the 7360 ISAM FX-16 subrack • Figure 2-2 shows the 7360 ISAM FX-8 subrack • Figure 2-3 shows the 7360 ISAM FX-4 subrack
2-2
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
2 — Subracks Figure 2-1 7360 ISAM FX-16 Subrack
Figure 2-2 7360 ISAM FX-8 Subrack
Figure 2-3 7360 ISAM FX-4 Subrack
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
2-3
2 — Subracks
Subrack Configurations Table 2-2 lists the possible subrack configurations. Table 2-2 Subrack Configurations Configuration
7360 FX-16
7360 FX-8
7360 FX-4
16
8
4
Maximum number of LT boards
The following figures show the general layout and the slot numbering for the different 7360 ISAM FX subracks:
• for a 7360 ISAM FX-16 subrack in LT mode; see Figure 2-4 • for a 7360 ISAM FX-8 subrack; see Figure 2-5 • for a 7360 ISAM FX-4 subrack; see Figure 2-6
LT 16
LT 15
LT 14
LT 13
LT 12
LT 11
LT 9
LT 10
NT B
NT A
NTIO
LT 8
LT 7
LT 6
LT 5
LT 4
LT 3
LT 2
LT 1
Figure 2-4 7360 ISAM FX-16 subrack
CBs, LEDs and switches Fan unit Connectors
2-4
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
2 — Subracks Figure 2-5 7360 ISAM FX-8 subrack LT 8 LT 7 LT 6 LT 5 LT 4 LT 3 LT 2
FAN
LT 1 NT B NT I/O NT A NGFC-E
Figure 2-6 7360 ISAM FX-4 subrack LT 4 LT 3 LT 2 LT 1 NT B
FAN
NT I/O NT A NGFC-F
NT Redundancy The protection scheme for NT redundancy is 1+1 (active/active) in the data plane, and 1:1 (active/standby) in the control and management plane.
Fan Unit One fan unit provides forced air cooling in the subrack. The fan unit is a field replaceable unit in the subrack fan area, it plugs directly into the backplane. The fan unit can be equipped with a dust filter.
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
2-5
2 — Subracks
2.4
Supported Plug-in Units Table 2-3 lists the supported plug-in units in the 7360 FX subracks for the current release. Table 2-3 Supported Units in 7360 FX Subracks Slot
Plug-in Unit
Description
NT A
FANT-F AC
480 Gbps NT board
NT B
FANT-F AC
480 Gbps NT board
NTIO
FNIO-B
NT I/O board with 8 supplementary uplinks
LT slot
NELT-B
36-line Ethernet (FE/GE) LT board
NGLT-A
GPON LT board with 8 GPON interfaces
FPLT-A
EPON LT board with 8 EPON interfaces
NGFC-E
General facilities and control board for FX-8 subrack
NGFC-F
General facilities and control board for FX-4 subrack
AFAN-H NB
Fan unit for FX-16 subrack
AFAN-E
Fan unit for FX-8 subrack
AFAN-X
Fan unit for FX-4 subrack
General facilities board
Fan area
Note — For detailed information about the plug-in units, refer to the relevant UDS. The used mnemonics are explained in Appendix “Board Mnemonics”.
2-6
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
2 — Subracks
2.5
Dummy Front Panels Dummy front panels must be mounted on any unused slot of a subrack for the following purposes:
• • • •
To ensure EMC compliance To ensure thermal compliance via a correct airflow in the subrack To ensure safety by avoiding direct contact with backplane connectors At slot deployment, the dummy front plate is replaced by the appropriate board and the cables are connected to the board.
For NT Board This panel (code 3FE 65651 AA) must be used when the second NT board is not installed. Figure 2-7 shows the dummy front panel for NT board. Figure 2-7 Dummy Front Panel for NT Board
For Optical Boards When optical cabling is already foreseen for not-installed optical LT boards (NGLT-A, FPLT-A), the optical cables must be fixed on dummy front panels (code 3FE 65005 AA). Figure 2-8 shows the dummy front panel.
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
2-7
2 — Subracks Figure 2-8 Dummy Front Panel for Optical LT boards
Dust cap
2-8
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
3—
Physical Rack Equipment
3.1 General
3-2
3.2 Universal Rack 3.3 Side Plates
3-5
3.4 Rack Doors
3-6
3.5 Key Locks
3-2
3-7
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
3-1
3 — Physical Rack Equipment
3.1
General The rack equipment can be delivered as a preassembled rack or in separate kits. This rack assembly is a universal rack cabinet, dimensions 2200 mm x 600 mm x 300 mm, which can be equipped with subracks, accompanying fan units and power and alarm cabling. Each rack configuration is ordered with a specific ordering code. Different parts can also be delivered separately or in kits, the assembly is done on site at the customer.
3.2
Universal Rack
Cabinet Types Table 3-1 shows the specifications of the universal rack. Table 3-1 Cabinet Type used for FX Equipment Type
Code
Height
Floorspace
Drawing
Universal
3FE 28688 AA
2200 mm
600 x 300 mm
Figure 3-1
Figure 3-1 Universal Rack
3-2
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
3 — Physical Rack Equipment
Transport Bracket
The transport bracket is mounted on the universal rack to protect the door from damage during transport. Figure 3-2 Transport Bracket
Transport bracket
On site the bracket must be removed.
Cabling Space As shown in Figure 3-1, the universal cabinet provides the space required for cabling. Position and dimensions of side holes are adapted for routing cables of all subracks in any configuration. If required, the bottom plate can be removed as shown in Figure 3-3, to free bottom holes that allow cable routing under raised floor.
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
3-3
3 — Physical Rack Equipment Figure 3-3 Top and inside Bottom View
Top view
Bottom view inside cabinet
Floor plate mounted
3-4
Floor plate removed (cable routing via bottom holes)
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
3 — Physical Rack Equipment
3.3
Side Plates Table 3-2 specifies the items which are required to equip a universal rack with side plates (left or right). Table 3-2 Side Plate Fixing Items Description
Quantity
Item No. on Figure 3-4
Side plate
2
1
Screw M4
20
2
Washer M4
20
3
The same kit is used for mounting a side plate on the left or on the right. Figure 3-4 shows the right side plate. Figure 3-4 Mounting Side Plate on Universal Rack
When mounting or dismounting the side plate, always remove the corner upright (item 4 in Figure 3-4) first. Each side plate is mounted with 5 screws and washers on the front and 5 screws and washers on the side.
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
3-5
3 — Physical Rack Equipment
3.4
Rack Doors One universal door is available (code 3FE 20207 JC). The door opens to the left and can be closed by means of two door latch locks. Figure 3-5 Universal Rack with Right Side Door
Refer to the 7360 ISAM FX Hardware Installation Manual for installation procedure.
3-6
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
3 — Physical Rack Equipment
3.5
Key Locks The door latch locks can be replaced on site by key locks. A key lock kit can be ordered separately (code 3FE 25800 AA). This kit contains two key locks, two keys and instructions to replace the standard latch locks by key locks. Figure 3-6 Key Lock Kit
Refer to the 7360 ISAM FX Hardware Installation Manual for installation procedure.
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
3-7
3 — Physical Rack Equipment
3-8
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
4—
Rack Configurations
4.1 General
4-2
4.2 Rack Configurations
4-2
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
4-1
4 — Rack Configurations
4.1
General This chapter describes the supported rack configurations for the 7360 ISAM FX-16 subrack. An rack contains:
• • • •
4.2
A rack cabinet: 2200 mm high. A door opening/closing on the left or the right side with a handle or a lock. One or two subrack(s) depending on the rack configuration. One fan unit per equipped subrack, for equipment cooling.
Rack Configurations Table 4-1 gives an overview of all the possible rack configurations with 7360 ISAM FX-16 subracks. These configurations are shown in Figure 4-1. Table 4-1 Rack Configurations with 7360 ISAM FX-16 subracks Code
3FE 65679 AA
Cabinet
3FE 28688 AA
SR 1 Fan1
SR 2
3FE 65680 AA
NFXS-D
NFXS-D
(3FE 65209 AA)
(3FE 65209 AA)
AFAN-H (with dust filter)
AFAN-H (with dust filter)
(3EC 37533 NB)
(3EC 37533 NB)
-
NFXS-D (3FE 65209 AA)
Fan 2
-
AFAN-H (with dust filter) (3EC 37533 NB)
4-2
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
4 — Rack Configurations Figure 4-1 Rack Configurations with 7360 ISAM FX-16 subracks
3FE 65679 AA
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
3FE 65680 AA
4-3
4 — Rack Configurations
4-4
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
5—
SFP Optical Modules
5.1 Introduction
5-2
5.2 SFP Optical Modules
5-2
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
5-1
5 — SFP Optical Modules
5.1
Introduction This section lists the Alcatel-Lucent-approved Small Form Pluggable (SFP) modules that are supported for each board type.
5.2
SFP Optical Modules Table 5-1 lists the Alcatel-Lucent-approved Small Form Pluggable (SFP) optical modules that are supported for each board type. Table 5-2 lists different characteristics of these SFP modules.
FPLT-A
NGLT-A
NELT-B
Description
FNIO-B
Code
FANT-F
Table 5-1 Supported SFP Modules per Board Type
Fast Ethernet SFP 3FE 25777 AA
FE-FX
Y
3FE 25778 AA
FE-LX10
Y
3FE 29194 AA
FE BX-10-D
Y
3FE 29194 BA
FE BX-10-D
Y
3FE 29195 AA
FE BX-10-U
Y
3FE 63343 AA
100Base-T
Y
Gigabit Ethernet SFP 3FE 25773 AA
GE-SX
3FE 25774 AA
GE-LX
3FE 25775 AA
GE-EX
Y
3FE 25776 AA
GE-ZX
Y
3FE 25771 AA
GE-YX CWDM (24 dB)
Y
Y
3FE 25771 AB 3FE 25771 AC 3FE 25771 AD 3FE 25771 AE 3FE 25771 AF 3FE 25771 AG 3FE 25771 AH (1 of 2)
5-2
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
FPLT-A
GE-VX CWDM (32 dB)
NGLT-A
3FE 25771 CA
NELT-B
Description
FNIO-B
Code
FANT-F
5 — SFP Optical Modules
3FE 29549 CA 3FE 29550 CA 3FE 29551 CA 3FE 29552 CA 3FE 29553 CA 3FE 29554 CA 3FE 29555 CA 3FE 25772 AA
GE-BX10-U
Y
3FE 25772 AB
GE-BX10-D
Y
Y
Y
3FE 28784 AA
1000Base-T
Y
Y
Y
3FE 28785 AA
GE-BX40-U
Y
3FE 28785 AB
GE-BX40-D
Y
SFP+ 3FE 62600 AA
10GE-R
3FE 62600 CA
10GE-R
3FE 62600 DA
10GE-R
Y
3FE 62600 EA
10GE-R
Y
3FE 65608 AA
10GE-R
Y
3FE 63264 AA
10GE-R
Y
3FE 65831 AA
10GE-R
Y
3FE 65832 AA
10GE-R
Dual SFP 3FE 65106 AA
GE-BX10-D
Y
3FE 65107 AA
FE-BX10-D
Y
FE-BX10-D
Y
GE-BX-10-D
Y
3FE 66131
AA(1)
GPON SFP 3FE 53441 AC
GPON SFP B+
Y
3FE 53441 BA
GPON SFP C+
Y
3FE 53441 CC with OTDR
GPON SFP B+ with OTDR
Y
EPON SFP 3FE 53606 AA
EPON PX20+
Y
3FE 66282 AA
EPON PX20+ OTDR
Y
(2 of 2) Notes (1) This is a dual-rate compact SFP
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
5-3
5 — SFP Optical Modules Table 5-2 Characteristics of Approved SFP Modules Code
Description
Wavelength (nm)
Operating Case Temp. Range (°C)
Optical Budget (dB)
Reach (km)
Fiber
Bidi /Uni
UDS(1)
DAAA
Fast Ethernet SFP 3FE 25777 AA
FE-FX
1310
-40..+85
12
0.550
MM
Uni
3FE 25778 AA
FE-LX10
1310
-40..+85
16
15
SM
Uni
3FE 29194 AA
FE BX-10-D
TX: 1550
-40..+85
14
10
SM
Bidi
-40..+85
14
10
SM
Bidi
-40..+85
14
10
SM
Bidi
NA
0..+70
NA
0.100
Cat5
NA
PAAA
CAAA
FAAA
RX: 1310 3FE 29194 BA
FE BX-10-D
TX: 1490 RX: 1310
3FE 29195 AA
FE BX-10-U
TX: 1310 RX: 1550
3FE 63343 AA
100Base-T
Gigabit Ethernet SFP 3FE 25773 AA
GE-SX
850
-40..+85
7
0.550
MM
Uni
3FE 25774 AA
GE-LX
1310
-40..+85
11
10
SM
Uni
3FE 25775 AA
GE-EX
1310
-40..+85
18
40
SM
Uni
3FE 25776 AA
GE-ZX
1550
-40..+85
24
80
SM
Uni
3FE 25771 AA
GE-YX
1471
-40..+85
22
62
SM
Uni
-5..+85
31
120
SM
Uni
3FE 25771 AB 3FE 25771 AC
CWDM (24 dB)
1491 1511
3FE 25771 AD
1531
3FE 25771 AE
1551
3FE 25771 AF
1571
3FE 25771 AG
1591
3FE 25771 AH
1611
3FE 25771 CA 3FE 29549 CA 3FE 29550 CA
GE-VX CWDM (32 dB)
AAAA
1471 1491 1511
3FE 29551 CA
1531
3FE 29552 CA
1551
3FE 29553 CA
1571
3FE 29554 CA
1591
3FE 29555 CA
1611
(1 of 2)
5-4
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
5 — SFP Optical Modules
Code
Description
Wavelength (nm)
Operating Case Temp. Range (°C)
Optical Budget (dB)
Reach (km)
Fiber
Bidi /Uni
UDS(1)
3FE 25772 AA
GE-BX10-U
TX: 1310
-40..+85
9
10
SM
Bidi
GAAA
-40..+85
9
10
SM
Bidi
-40..+85
19
40
SM
Bidi
-40..+85
19
40
SM
Bidi
RX: 1490 3FE 25772 AB
GE-BX10-D
TX: 1490 RX: 1310
3FE 28785 AA
GE-BX40-U
TX: 1310 RX: 1550
3FE 28785 AB
GE-BX40-D
TX: 1550 RX: 1310
3FE 28784 AA
1000Base-T
NA
0..+85
NA
0.100
Cat5
NA
EAAA
3FE 62600 AA
10GE-R
1310
-40..+85
10
10
SM
Uni
MAAA
3FE 62600 CA
10GE-R
1310
-5..+85
10
10
SM
Uni
3FE 62600 DA
10GE-R
1310
0..+70
10
10
SM
Uni
3FE 62600 EA
10GE-R
1310
-40..+85
10
10
SM
Uni
3FE 65608 AA
10GE-R
850
0..+70
11
0.3
MM
Uni
3FE 63264 AA
10GE-R
850
-40..+85
11
0.3
MM
Uni
3FE 65831 AA
10GE-R
1550
-40..+85
15
40
SM
Uni
3FE 65832 AA
10GE-R
1550
-40..+85
24
80
SM
Uni
GE-BX10-D
TX: 1490
-40..+85
9
10
SM
Bidi
-40..+85
14
10
SM
Bidi
-40..+85
8 (FE)
10
SM
Bidi
SFP+
Dual SFP 3FE 65106 AA
RX: 1310 3FE 65107 AA
FE-BX10-D
TX: 1550 RX: 1310
3FE 66131 AA
FE-BX10-D
TX: 1490
GE-BX10-D
RX: 1310
Class B+, normal
TX: 1490
Class C+, normal
TX: 1490
Class B+, with OTDR
TX: 1490
EPON PX20+
TX: 1490
TAAA
9 (GE)
GPON SFP 3FE 53441 AC 3FE 53441 BA 3FE 53441 CC
-40..+85
28
30
SM
Bidi
-5..+70
32
60
SM
Bidi
-40..+85
28
30
SM
Bidi
-40..+85
32
20
SM
Bidi
-40..+85
32
20
SM
Bidi
RX: 1310 RX: 1310
RAAA
RX: 1310
EPON SFP 3FE 53606 AA
UAAA
RX: 1310 3FE 66282 AA
EPON PX20+ OTDR
TX: 1490 RX: 1310
(2 of 2)
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
5-5
5 — SFP Optical Modules Note (1)
5-6
For more detailed information on the different characteristics of the SFP module, refer to UDS 3HH 01046 xxxx TQZZA (where xxxx is the document variant indicated in this column).
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
A.
Board Mnemonics
A.1 Board Mnemonics
A-2
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
A-1
A. Board Mnemonics
A.1
Board Mnemonics Table A-1 gives the used board mnemonics with their description. Table A-1 Mnemonics
A-2
Mnemonic
Description
AFAN-H
Fan unit - version H
AFAN-E
FX-8 Fan unit - version E
AFAN-X
FX-4 Fan unit - version X
FANT-F
Combined NT Unit - version F
FNIO-B
FX FE/GE Network Termination I/O Applique - version B
FPLT-A
EPON Line Termination Board - version A
NELT-B
36-line Fast Ethernet/Gigabit Ethernet Line Termination Unit - version B
NFXS-D
FX-16 Shelf for ETSI/MII
NFXS-E
FX-8 Shelf for ETSI/MII
NFXS-F
FX-4 Shelf for ETSI/MII
NGFC-E
General Facilities Card - version E
NGFC-F
General Facilities Card - version F
NGLT-A
GPON Line Termination Board - version A
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Index
Numbers
M
7360 FX rack configurations, 4-2 subrack configurations, 2-4 subrack types, 2-2 Supported plug-in units, 2-6
Management Network, 1-17
C CLEI codes, 1-26
D Dimensioning, 1-19 GPON, 1-24 Dummy front panels, 2-7
G GPON dimensioning, 1-24
N Network topology, 1-2 Network side, 1-4 User side, 1-3
P Plug-in units, 2-6
R Redundancy support 1+1 NT, 1-25
S
I
SFP modules, 5-2 System architecture, 1-6 IHub, 1-16
IWF capabilities, 1-19
T Technical specifications P-OLT connection capacity, 1-25
Alcatel-Lucent 7360 ISAM FX R4.3 July 2011 3HH-10116-AAAA-TCZZA Edition 01 Released Product Information
IN-1
Index U — Universal rack
U Universal rack, 3-2 Locks, 3-7 Rack door, 3-6 Side plates, 3-5 type, 3-2
IN-2
July 2011 Alcatel-Lucent 7360 ISAM FX R4.3 Product Information Edition 01 Released 3HH-10116-AAAA-TCZZA
Customer documentation and product support
Customer documentation http://www.alcatel-lucent.com/myaccess Product manuals and documentation updates are available at alcatel-lucent.com. If you are a new user and require access to this service, please contact your Alcatel-Lucent sales representative.
Technical Support http://www.alcatel-lucent.com/support
Documentation feedback
[email protected]
© 2011 Alcatel-Lucent. All rights reserved. 3HH-10116-AAAA-TCZZA Edition 01 Released