3fe54967aaaatczza01_v1_7360 Isam Fx Olt r4.4, Ansi Product Information Guide

March 31, 2017 | Author: seamesai | Category: N/A
Share Embed Donate


Short Description

Download 3fe54967aaaatczza01_v1_7360 Isam Fx Olt r4.4, Ansi Product Information Guide...

Description

ANSI PRODUCT INFORMATION GUIDE

Alcatel-Lucent 7360 INTELLIGENT SERVICES ACCESS MANAGER FX | RELEASE 04.04 ANSI PRODUCT INFORMATION GUIDE

3FE 54967 AAAA TCZZA Edition 01

Alcatel-Lucent Proprietary This document contains proprietary information of Alcatel-Lucent and is not to be disclosed or used except in accordance with applicable agreements. Copyright 2012 © Alcatel-Lucent. All rights reserved.

Alcatel-Lucent assumes no responsibility for the accuracy of the information presented, which is subject to change without notice. Alcatel, Lucent and the Alcatel-Lucent logo are registered trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. Copyright 2012 Alcatel-Lucent. All rights reserved. Disclaimers

Alcatel-Lucent products are intended for commercial uses. Without the appropriate network design engineering, they must not be sold, licensed or otherwise distributed for use in any hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life-support machines, or weapons systems, in which the failure of products could lead directly to death, personal injury, or severe physical or environmental damage. The customer hereby agrees that the use, sale, license or other distribution of the products for any such application without the prior written consent of Alcatel-Lucent, shall be at the customer's sole risk. The customer hereby agrees to defend and hold Alcatel-Lucent harmless from any claims for loss, cost, damage, expense or liability that may arise out of or in connection with the use, sale, license or other distribution of the products in such applications. This document may contain information regarding the use and installation of non-Alcatel-Lucent products. Please note that this information is provided as a courtesy to assist you. While Alcatel-Lucent tries to ensure that this information accurately reflects information provided by the supplier, please refer to the materials provided with any non-Alcatel-Lucent product and contact the supplier for confirmation. Alcatel-Lucent assumes no responsibility or liability for incorrect or incomplete information provided about non-Alcatel-Lucent products. However, this does not constitute a representation or warranty. The warranties provided for Alcatel-Lucent products, if any, are set forth in contractual documentation entered into by Alcatel-Lucent and its customers. This document was originally written in English. If there is any conflict or inconsistency between the English version and any other version of a document, the English version shall prevail.

When printed by Alcatel-Lucent, this document is printed on recycled paper.

Preface

This preface provides general information about the documentation set for the 7360 Intelligent Services Access Manager FX (7360 ISAM FX ) for ANSI.

Scope This documentation set provides information about safety, features and functionality, ordering, hardware installation and maintenance, CLI and TL1 commands, and software installation procedures.

Audience This documentation set is intended for planners, administrators, operators, and maintenance personnel involved in installing, upgrading, or maintaining the 7360 ISAM FX system.

Prerequired knowledge The reader must be familiar with general telecommunications principles.

Assistance and ordering phone numbers Alcatel-Lucent provides global technical support through regional call centers. Phone numbers for the regional call centers are available at the following URL: http://www.alcatel-lucent.com/myaccess For ordering information, contact your Alcatel-Lucent sales representative.

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

iii

Preface

Safety information See the 7360 ISAM FX Safety Manual for safety information. The following are examples of how special information is presented in this document. Danger — Danger indicates that the described activity or situation

may result in serious personal injury or death; for example, high voltage or electric shock hazards. Warning — Warning indicates that the described activity or situation

may, or will, cause equipment damage or serious performance problems. Caution — Caution indicates that the described activity or situation may, or will, cause service interruption.

Note — A note provides information that is, or may be, of special

interest.

Document conventions The following conventions are used in this documentation set.

Acronyms See the glossary for the expansion of acronyms used in this documentation set.

Release notes See the release notes (such as the customer release notes or emergency fix release note) issued for software loads of the 7360 ISAM FX before you install or use the 7360 ISAM FX. The release notes provide important information about the software load.

Documents Table 1 lists the documents that make up the 7360 ISAM FX documentation set.

iv

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

Preface Table 1 7360 ISAM FX documentation set for ANSI Title

Description

General documentation Product Information

Provides general system and ordering information for the 7360 ISAM FX

System Description for FD 100/320Gbps NT and FX NT

Provides conceptual information for the:

• •

Safety Manual

7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT

Provides general safety guidelines when handling, installing, or operating the 7360 ISAM FX equipment

Hardware documentation and unit data sheets FX Hardware Installation Guide

Describes the hardware installation for the 7360 ISAM FX equipment

UDS NFXS-D (FX-16)

Describes the 7360 ISAM FX-16 slot shelf

UDS NFXS-E (FX-8)

Describes the 7360 ISAM FX-8 slot shelf

UDS NFXS-F (FX-4)

Describes the 7360 ISAM FX-4 slot shelf

UDS NGFC-G

Describes the 7360 ISAM FX-4 general facilities card

UDS NGFC-H

Describes the 7360 ISAM FX-8 general facilities card

UDS FANT-F

Describes the NT card

UDS NELT-B

Describes the GPON LT board

(1)

version B

UDS NGLT-A

Describes the GPON LT board

(1)

version A

UDS dummy front panel FX NT

Describes the dummy front panel (filler plate) for the NT card

UDS dummy front panel FX LT

Describes the dummy front panel (filler plate) for the LT card

UDS AFAN-H

Describes the fan unit for the 7360 ISAM FX-16

UDS AFAN-E

Describes the fan unit for the 7360 ISAM FX-8

UDS AFAN-X

Describes the fan unit for the 7360 ISAM FX-4

TL1 documentation TL1 Commands and Messages for FD 100/320Gbps NT and FX NT

Describes the TL1 commands and messages for the:

• •

Operations and Maintenance Using TL1 for FD 100/320Gbps NT and FX NT

7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT

Provides task-oriented procedures using TL1 for operating and maintaining the:

• •

7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT

CLI documentation CLI Commands for FD 100/320Gbps NT and FX NT

Describes the CLI commands for the:

• •

7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT

(1 of 2)

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

v

Preface

Title

Description

Operations and Maintenance Using CLI for FD 100/320Gbps NT and FX NT

Provides task-oriented procedures using CLI for operating and maintaining the:

• •

7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT

IHub System Basics, Management and OAM Guide for FD 100/320Gbps NT and FX NT

Describes the IHub system basics, system management and OAM (Operations and Maintenance)

IHub Interface Guide for FD 100/320Gbps NT and FX NT

Describes the IHub system interfaces

IHub QoS Guide for FD 100/320Gbps NT and FX NT

Describes the IHub quality of service

IHub Router Configuration and Protocols Guide for FD 100/320Gbps NT and FX NT

Describes the IHub router configuration and router protocols

IHub Services Guide for FD 100/320Gbps NT and FX NT

Describes the IHub services

MPLS Guide for FD 100/320Gbps NT and FX NT

Describes the IHub MPLS services

Software documentation Software Installation Guide

Describes the software management of the 7302 ISAM, the 7330 ISAM FTTN and the 7360 ISAM FX equipment

Software Upgrade and Migration Application Procedures

Provides instructions for using the automated tools for upgrading and migrating the software for the 7302 ISAM, the 7330 ISAM FTTN and the 7360 ISAM FX

(2 of 2) Note (1)

vi

The term “board” and “card” are both used in the 7360 ISAM FX documentation set. “Board” is used in reference to ETSI terminology, and “card” is used in reference to ANSI terminology.

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

Contents

Preface

iii

Scope ................................................................................................................... iii Audience ................................................................................................................... iii Prerequired knowledge ................................................................................................. iii Assistance and ordering phone numbers ........................................................................ iii Safety information........................................................................................................ iv Document conventions ................................................................................................. iv Release notes .............................................................................................................. iv Documents .................................................................................................................. iv

System and equipment overview 1—

System overview 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8

2—

Introduction ............................................................................................... 1-2 Feature descriptions.................................................................................... 1-6 System architecture .................................................................................... 1-7 Network management............................................................................... 1-14 Equipment management ........................................................................... 1-16 Card capabilities and dimensioning............................................................. 1-17 NT redundancy support............................................................................. 1-23 CLEI codes............................................................................................... 1-24

Shelves 2.1 2.2

1-1

2-1

Overview ................................................................................................... 2-2 7360 ISAM FX shelves................................................................................. 2-2

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

vii

Contents

2.3 2.4

3—

Rack mounting configurations 3.1 3.2 3.3 3.4 3.5

4—

Supported plug-in units............................................................................... 2-7 Dummy front panels ................................................................................... 2-8

Overview ................................................................................................... 3-2 Rack equipment ......................................................................................... 3-2 7360 ISAM FX-16 rack mounting configurations ............................................ 3-3 7360 ISAM FX-8 rack mounting configurations .............................................. 3-5 7360 ISAM FX-4 rack mounting configurations .............................................. 3-8

Optical modules 4.1 4.2

3-1

4-1

Overview ................................................................................................... 4-2 Characteristics............................................................................................ 4-2

Planning and ordering 5—

Planning the equipment 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.12

6—

6-1

Overview ................................................................................................... 6-2 Racks and mounting parts ........................................................................... 6-3 Shelves ...................................................................................................... 6-6 GFCs.......................................................................................................... 6-7 Fan units and fan filters .............................................................................. 6-8 NT card and dummy front panel .................................................................. 6-9 NTIO card and dummy front panel............................................................. 6-10 LT cards and dummy front panels .............................................................. 6-10 Optical modules........................................................................................ 6-11 Cables ..................................................................................................... 6-13

Mnemonics A.1

viii

Overview ................................................................................................... 5-2 Network considerations ............................................................................... 5-2 Rack considerations .................................................................................... 5-4 Shelf considerations .................................................................................... 5-4 LT card considerations ................................................................................ 5-5 NT card considerations................................................................................ 5-5 V-OLT and video coupler equipment considerations....................................... 5-5 Installation considerations ........................................................................... 5-7 Power considerations .................................................................................. 5-8 Maintenance considerations......................................................................... 5-8 Software licensing information ..................................................................... 5-8 Documentation ........................................................................................... 5-8

Ordering the equipment 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 6.10

A.

5-1

A-1

Mnemonics overview...................................................................................A-2 May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

Contents

Glossary

Index

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

ix

Contents

List of figures Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure

1-1 Basic 7360 ISAM FX network topology ........................................................ 1-3 1-2 Cascading topology mode .......................................................................... 1-4 1-3 Star topology mode ................................................................................... 1-4 1-4 Ring topology mode .................................................................................. 1-5 1-5 Network connections ................................................................................. 1-6 1-6 7360 ISAM FX functional components ......................................................... 1-8 1-7 7360 ISAM FX system components ............................................................. 1-8 1-8 7360 ISAM FX forwarding architecture ........................................................ 1-9 1-9 7360 ISAM FX network management ........................................................ 1-15 1-10 7360 ISAM FX management topology ..................................................... 1-15 2-1 7360 ISAM FX-16 shelf .............................................................................. 2-3 2-2 7360 ISAM FX-8 shelf ................................................................................ 2-4 2-3 7360 ISAM FX-4 shelf ................................................................................ 2-4 2-4 Shelf configuration of 7360 ISAM FX-16 ...................................................... 2-5 2-5 Shelf configuration of 7360 ISAM FX-8........................................................ 2-6 2-6 Shelf configuration of 7360 ISAM FX-4........................................................ 2-6 2-7 Heat and fiber management baffle for 7360 ISAM FX-16 .............................. 2-7 2-8 Dummy front panel for NT card.................................................................. 2-9 2-9 Dummy front panel for optical LT card...................................................... 2-10 2-10 Universal dummy front panel for NTIO card ............................................ 2-11 3-1 Rack mounting configurations for 7360 ISAM FX-16 (3FE 66742 AB)............. 3-4 3-2 Horizontal rack mounting configurations for 7360 ISAM FX-8 in an EIA standard 19 in. rack ........................................................................... 3-6 Figure 3-3 Horizontal rack mounting configurations for 7360 ISAM FX-8 in a 23 in. rack................................................................................................... 3-7 Figure 3-4 Horizontal rack mounting configurations for 7360 ISAM FX-4 in an EIA standard 19 in. rack ........................................................................... 3-9 Figure 3-5 Horizontal rack mounting configurations for 7360 ISAM FX-4 in a 23 in. rack................................................................................................. 3-10

List of tables Table Table Table Table Table Table Table Table Table Table Table Table Table Table

x

1 7360 ISAM FX documentation set for ANSI......................................................... v 1-1 Features for 7360 ISAM FX R4.3.01 .............................................................. 1-6 1-2 Features for 7360 ISAM FX R4.3.02 .............................................................. 1-7 1-3 Features for 7360 ISAM FX R4.4................................................................... 1-7 1-4 Supported LT cards ................................................................................... 1-10 1-5 Mapped items in a 7360 ISAM FX system .................................................... 1-11 1-6 FANT-F in 7360 ISAM FX-16....................................................................... 1-12 1-7 FANT-F in 7360 ISAM FX-8......................................................................... 1-12 1-8 FANT-F in 7360 ISAM FX-4......................................................................... 1-13 1-9 Manager overview ..................................................................................... 1-16 1-10 NT card dimensioning .............................................................................. 1-17 1-11 Faceplate port applicability for SyncE ........................................................ 1-18 1-12 IWF capabilities....................................................................................... 1-18 1-13 Ethernet frame size for LT cards ............................................................... 1-20

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

Contents

Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table

1-14 LT card dimensioning information ............................................................. 1-21 1-15 GPON-specific dimensioning information ................................................... 1-22 1-16 Total number of ports per LT card ............................................................ 1-23 1-17 NT Redundancy support-ready hardware modules ..................................... 1-24 1-18 CLEI codes.............................................................................................. 1-24 2-1 7360 ISAM FX shelves supported.................................................................. 2-2 2-2 Shelf configurations..................................................................................... 2-5 2-3 Mounting options/kits for 7360 ISAM FX shelves ............................................ 2-7 2-4 Supported plug-in units in 7360 ISAM FX shelves........................................... 2-8 3-1 7360 ISAM FX supported rack equipment...................................................... 3-2 3-2 Rack mounting configurations for 7360 ISAM FX-16....................................... 3-3 3-3 Horizontal rack mounting configurations for 7360 ISAM FX-8.......................... 3-5 3-4 Horizontal rack mounting configurations for 7360 ISAM FX-4.......................... 3-8 4-1 Characteristics of approved optical modules .................................................. 4-2 5-1 Number of shelves per rack ......................................................................... 5-4 5-2 Ordering plug-in units and cables for the 7360 ISAM FX shelves ..................... 5-4 5-3 Number of LT ports per LT card ................................................................... 5-5 5-4 Number of NT ports per NT card .................................................................. 5-5 6-1 7360 ISAM FX equipment............................................................................. 6-2 6-2 Rack mounting configurations ...................................................................... 6-3 6-3 Racks ......................................................................................................... 6-3 6-4 FEMA level rack mounting parts for 7360 ISAM FX-16 .................................... 6-3 6-5 Rack mounting parts for 7360 ISAM FX-8 and 7360 ISAM FX-4 ...................... 6-4 6-6 Orderable 7360 ISAM FX shelves .................................................................. 6-6 6-7 Orderable GFCs........................................................................................... 6-7 6-8 Orderable fan units and filters ...................................................................... 6-8 6-9 Orderable NT card and NT dummy front panel .............................................. 6-9 6-10 Orderable NTIO dummy front panel .......................................................... 6-10 6-11 Orderable LT cards and LT dummy front panels......................................... 6-10 6-12 Orderable optical modules........................................................................ 6-11 6-13 Orderable CO external alarm cables .......................................................... 6-13 A-1 Equipment mnemonics ................................................................................A-2

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

xi

Contents

xii

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

System and equipment overview 1 — System overview 2 — Shelves 3 — Rack mounting configurations 4 — Optical modules

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

1 — System overview

1.1 Introduction

1-2

1.2 Feature descriptions

1-6

1.3 System architecture

1-7

1.4 Network management 1.5 Equipment management

1-14 1-16

1.6 Card capabilities and dimensioning 1.7 NT redundancy support 1.8 CLEI codes

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

1-17

1-23

1-24

1-1

1 — System overview

1.1

Introduction This chapter provides general information about the 7360 ISAM FX system including network topology, feature descriptions, system architecture, network management, equipment management, card capabilities, NT redundancy support, and CLEI code information.

Network topology The 7360 ISAM FX system is a frame-based multi-service access platform, offering high-density fiber connections for multimedia, high-speed Internet access, voice, and business services. Figure 1-1 shows the basic 7360 ISAM FX network topology.

1-2

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

1 — System overview Figure 1-1 Basic 7360 ISAM FX network topology IP edge router/ BRAS NSP IP backbone

Ethernet Switch FE/GE/ 10GE

Ethernet DS1/E1

ISAM

NSP IP backbone

EMAN

Video FE/GE/ 10GE NSP IP backbone

ISAM ISAM shelf Ethernet

FE/GE/10GE

Eth LT

FE/GE/10GE

DS1/E1 Video Ethernet ONT

ONT

OMCI GPON

GPON LT

NT

EPON LT

OAM EPON

ISAM OLT

22417

Note 1 — Possible user interface types are not limited to the types

shown in the Figure 1-1. Note 2 — A link is a term that refers to the physical layer of an

interface of the 7360 ISAM FX, for example, an Ethernet link.

Subscriber side At the subscriber side, each 7360 ISAM FX shelf can terminate:

• Ethernet user interfaces • PON interfaces

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

1-3

1 — System overview

You can connect subtending DSLAMs to the FE/GE/10GE links at the subscriber side in:

• cascading topology mode: a chain of one subtending ISAM per ISAM; see Figure 1-2

• star topology mode: multiple subtending ISAMs per ISAM; see Figure 1-3 • ring topology mode: (except when there is a ring behind a Hub-ISAM); see Figure 1-4 Figure 1-2 Cascading topology mode Cascading up to three levels k*FE/GE/10GE

k*FE/GE/10GE

ISAM ISAM User interfaces

ISAM EMAN

User interfaces

User interfaces 22420

Figure 1-3 Star topology mode

k*FE/GE/10GE

ISAM

ISAM EMAN

User interfaces

User interfaces

ISAM

k*FE/GE/10GE

User interfaces 22421

1-4

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

1 — System overview Figure 1-4 Ring topology mode

k*FE/GE/10GE

ISAM

User interfaces k*FE/GE/10GE

ISAM

ISAM EMAN User interfaces

User interfaces

ISAM k*FE/GE/10GE User interfaces 22422

Network side At the network side, the 7360 ISAM FX terminates FE, GE, or 10GE links. Following are possible configurations.

• Connect to one or more Ethernet switches. Ethernet links can be connected to one or more Ethernet switches. These Ethernet switches forward the frames over the Ethernet-based aggregation access network until they reach the IP edge router or BRAS of the corresponding NSP. At the IP edge router or BRAS, the frames enter the IP backbone of the NSP. • Connect more than one FE/GE/10GE link (link aggregation). In case of more than one link, Ethernet link aggregation is used. • Connect directly to an IP edge router. The 7360 ISAM FX can be connected directly to the IP edge router or BRAS. The Ethernet aggregation network is reduced to one or more parallel Ethernet links. • Connect to a MPLS network. Figure 1-5 shows the 7360 ISAM FX system network connections.

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

1-5

1 — System overview Figure 1-5 Network connections IP edge router/ BRAS NSP IP backbone

Ethernet Switch User interfaces

m x FE/GE/10GE

NSP IP backbone

EMAN

ISAM FE/GE m x FE/GE/10GE

NSP IP backbone User interfaces NSP IP backbone

ISAM FE/GE

22423

1.2

Feature descriptions This section provides a brief description of the features for the 7360 ISAM FX system.

Release 4.3.01 features Table 1-1 describes the features for 7360 ISAM FX R4.3.01. Table 1-1 Features for 7360 ISAM FX R4.3.01 Feature ANSI hardware support

Description Following is a list of ANSI-supported hardware for release 4.3.01:

• • • • • • • • • • • •

NFXS-D, 16-slot shelf NFXS-E, 8-slot shelf NFXS-F, 4-slot shelf FANT-F, BC variant NT card with a 480 Gbps switch NELT-B, GPON LT card version B NGLT-A, GPON LT card version A PDBP-C, GFC for the 16-slot shelf (preinstalled) NGFC-H, GFC for the 8-slot shelf NGFC-G, GFC for the 4-slot shelf AFAN-H, fan unit for 16-slot shelf AFAN-E, fan unit for 8-slot shelf AFAN-X, fan unit for 4-slot shelf

Table 1-2 describes the features for 7360 ISAM FX R4.3.02.

1-6

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

1 — System overview Table 1-2 Features for 7360 ISAM FX R4.3.02 Feature

Description

ANSI hardware support

FANT-F, BD variant NT card with a 480 Gbps switch

Table 1-3 describes the features for 7360 ISAM FX R4.4. Table 1-3 Features for 7360 ISAM FX R4.4 Feature

Description

ANSI hardware suppport

FGLT-A, 16 port GPON LT card NGLT-C, 8 port GPON LT card XG-PON1 OLT XFP N1 Ctemp XG-PON1 ONU SFP+ N2A Itemp

1.3

System architecture This section describes the 7360 ISAM FX system architecture including the functional and physical components, and IHub.

Functional components The 7360 ISAM FX is a multiplexer, which can be equipped with the following main cards:

• • • •

NT card (optionally 1+1 redundant) NTIO card (optional) (not currently supported) LT cards implementing the user interfaces GPON LT cards Note — The XG-PON1 LT card is not supported in the current release. Related information is provided in the customer documentation in anticipation of their subsequent availability.

Figure 1-6 shows the 7360 ISAM FX functional components.

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

1-7

1 — System overview Figure 1-6 7360 ISAM FX functional components

ISAM

NT

LT

NTIO

...

LT-applique 22424

The 7360 ISAM FX management plane, control plane, and most of the data plane are provided on the NT cards and on the LT cards. Figure 1-7 shows the 7360 ISAM FX system components. Figure 1-7 7360 ISAM FX system components LT

NT iHub

LT-Control

iHub control

Transport

IWF

Switch/Router

System control Data plane Control plane 22425

NT cards

The 7360 ISAM FX NT cards consist of an IHub subsystem and a system control subsystem.

• The IHub subsystem has enhanced L2 functionality (VPLS based) and L3 functionality (VPRN based) and consists of a 10 GE switch/router device, and IHub control SW. • The system control subsystem implements the management plane of the system (both the NT cards and the LT cards) and part of the control plane (subscriber management in particular). The system control consists of SW running on a general purpose processor, shared with the IHub control SW (on a separate processor core).

1-8

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

1 — System overview

LT cards

The 7360 ISAM FX LT cards provide an IWF, a transport subsystem, and an LT control subsystem.

• The transport subsystem terminates the physical layer of the user interfaces. The transport subsystem varies with the type of access technology used, such as Ethernet. • The IWF processes the packets in the fast path. The IWF is capable of handling frames at L2 (basically bridging) and L3 (basically IP forwarding), including sophisticated filtering and traffic management, all at the line rate of the transport medium. • The LT control subsystem provides the slow path control plane and internal operations and maintenance applications. GPON LT cards

The GPON functionality of the 7360 ISAM FX extends the system boundaries up to 128 ONTs over fiber that can reach tens of kilometers from the GPON LT cards located in a 7360 ISAM FX shelf. These GPON LT cards provide the physical interfaces from the 7360 ISAM FX shelf toward the CPE, or the ONTs. XG-PON1 LT cards

The XG-PON1 functionality of the 7360 ISAM FX provides higher speed data rates of 10G downstream and 2.5G updstream.

Physical components Figure 1-8 shows the forwarding architecture of the 7360 ISAM FX system. Figure 1-8 7360 ISAM FX forwarding architecture Network links Subtending links User links

NT

LT IHUB router

EMAN EPS

IHUB control

2-n

IWF

Transport LT control

Ethernet GPON EPON

CPE ONT ONT

NTIO System control

22426

A 7360 ISAM FX shelf consists of the following card types:

• NT cards • LT cards

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

1-9

1 — System overview

• NTIO card (not currently supported) • GFC card NT cards

The shelf can accommodate two NT cards. These NT cards can act as an active/standby pair for all functions. The FANT-F (480 Gbps) NT card is supported in 7360 ISAM FX equipment. This NT card with integrated IHub subsystem provides the following links on the front panel:

• 1 x fixed 10/100/1000Base-T port. • • • • •

This port operates in 10 Mb/s, 100 Mb/s, or 1 GE mode. 4 x 10 GE SFP+ port: This port operates in 1 GE mode (with standard SFP optics) and in 10 GE mode (with SFP+ optics). LCMI interface (RJ-45 connector) ToD/1PPS interface (RJ-45 connector) 10 MHz GPS interface (SMA connector) 1 PPS interface (SMA connector)

LT cards

The LT cards in the shelf consist of an IWF, the transport termination, and the LT control. The LT cards, also known as LIMs, use a different IWF between the user side and the Ethernet network side, depending on the card type. Table 1-4 lists the supported LT cards with their physical interface types, density (that is, number of lines per card), and IWF capability. Table 1-4 Supported LT cards LT card

Physical interfaces

Overlay

Density

NT interface

IWF

NELT-B

Ethernet



36

10 GE

L3

(1)

FGLT-A

GPON



16

40 GE

L3

(1) (2)

NGLT-A

GPON



8

10 GE

L3

(1) (2)

NGLT-C

GPON



8

20 GE

L3

(1) (2)

Notes (1) L3: IWF capability on Layer 2 and Layer 3. For an overview of the IWF capabilities, see section 1.6. (2) Not all L3 features are supported in these ports, see Table 1-12.

1-10

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

1 — System overview

GFC card

The GFC provides connections for external power, circuit breakers for system protection, visual indications for power availability, and collection and cascading of external alarms. Note — These cards are only used on the 7360 ISAM FX-8 and the 7360 ISAM FX-4.

NTIO card

The 7360 ISAM FX NTIO card plays the role of an applique to a single NT card, or to both NT cards, dependant on the NT redundancy configuration. The NTIO card can decouple NT equipment protection from up-link protection in case of a redundant NT pair. If the active NT fails, traffic on the NTIO external links will be switched automatically to and from the standby NT. Port mapping

The following tables list the port mapping for the 7360 ISAM FX system, that is, the mapping between the logical port numbers as used in the system and the physical port numbers as visible on the equipment (front panel numbering).

• Table 1-5 lists the mapped items in a 7360 ISAM FX system. • Table 1-6 lists the port mapping for the FANT-F card in a 7360 ISAM FX-16 shelf. • Table 1-7 lists the port mapping for the FANT-F card in a 7360 ISAM FX-8 shelf. • Table 1-8 lists the port mapping for the FANT-F card in a 7360 ISAM FX-4 shelf. Table 1-5 Mapped items in a 7360 ISAM FX system Item

Description

Physical port number

Physical switch device port number

Logical port number

Port number as denoted in the SNMP management interface

LT port number

For internal LT ports, the index of the LT in the main shelf that corresponds to this port (for local LTs only)

(index based) Front panel port number

For external ports, how this port is identified at the front panel of the card

Port state / configurability

For NTIO ports, how this port can be configured:

• • • •

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

UP for uplinks/subtending/user links DOWN for internal LT links FIXED for fixed configuration (UP or DOWN) CONF for configurable configuration (UP or DOWN)

1-11

1 — System overview Table 1-6 FANT-F in 7360 ISAM FX-16 Physical port number

Logical port number

LT slot number (index based)

Faceplate port number

Interface

10

15

1





12

16

2





16

17

3





18

18

4





32

19

5





34

20

6





41

21

7





43

22

8





45

23

9





37

24

10





22

25

11





8

26

12





39

27

13





28

28

14





20

29

15





17

30

16





2

5



1 (NT-A)

RJ-45

4

6



X1 (NT-A)

SFP+

5

7



X2 (NT-A)

SFP+

6

8



X3 (NT-A)

SFP+

7

9



X4 (NT-A)

SFP+

3

3



IEEE1588 (NT-A)





10



1 (NT-B)

RJ-45



11



X1 (NT-B)

SFP+



12



X2 (NT-B)

SFP+



13



X3 (NT-B)

SFP+



14



X4 (NT-B)

SFP+



4



IEEE1588 (NT-B)



Table 1-7 FANT-F in 7360 ISAM FX-8 Physical port number

Logical port number

LT slot number (index based)

Faceplate port number

Interface

10

15

1





12

16

2





(1 of 2)

1-12

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

1 — System overview

Physical port number

Logical port number

LT slot number (index based)

Faceplate port number

Interface

16

17

3





18

18

4





32

19

5





34

20

6





41

21

7





43

22

8





2

5



1 (NT-A)

RJ-45

4

6



X1 (NT-A)

SFP+

5

7



X2 (NT-A)

SFP+

6

8



X3 (NT-A)

SFP+

7

9



X4 (NT-A)

SFP+

3

3



IEEE1588 (NT-A)





10



1 (NT-B)

RJ-45



11



X1 (NT-B)

SFP+



12



X2 (NT-B)

SFP+



13



X3 (NT-B)

SFP+



14



X4 (NT-B)

SFP+



4



IEEE1588 (NT-B)



(2 of 2)

Table 1-8 FANT-F in 7360 ISAM FX-4 Physical port number

Logical port number

LT slot number (index based)

Faceplate port number

Interface

10

15

1





12

16

2





16

17

3





18

18

4





2

5



1 (NT-A)

RJ-45

4

6



X1 (NT-A)

SFP+

5

7



X2 (NT-A)

SFP+

6

8



X3 (NT-A)

SFP+

7

9



X4 (NT-A)

SFP+

3

3



IEEE1588 (NT-A)





10



1 (NT-B)

RJ-45



11



X1 (NT-B)

SFP+



12



X2 (NT-B)

SFP+

(1 of 2)

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

1-13

1 — System overview

Physical port number

Logical port number

LT slot number (index based)

Faceplate port number

Interface



13



X3 (NT-B)

SFP+



14



X4 (NT-B)

SFP+



4



IEEE1588 (NT-B)



(2 of 2)

IHub The IHub provides L2 bridging (based on VPLS) and IP routing (based on VPRN). The IHub has at least 28 ports with various specializations. A number of ports are used to make a connection at 1 Gb/s or at 2.5 Gb/s or at 10 Gb/s to an LT local in the shelf (one IHub link per LT). The connection speed depends on the LT capabilities; see Table 1-4. The FE/GE ports, which are not used for connecting LT cards (local or remote), and the 10GE ports, are available as network interfaces, interfaces to subtended DSLAM systems, or for connecting directly to users. These links serve network links, subtending links, or user links respectively. Use of these ports is possible through:

• link interfaces that are physically located on an NTIO card, connected via bidirectional P2P high-speed connections on the backplane to both NT cards These interfaces can also be used as electrical FE or GE interfaces, or optical GE, or 10GE interfaces, for uplink, subtending, or user links. The NTIO card contains an NT equipment protection switch per external link interface. Link protection and NT equipment protection can be performed independently from each other for links terminated on the NTIO. • link interfaces that are physically located on the NT card, as electrical FE or GE interfaces, or optical GE or 10 GE interfaces, for uplink, subtending, or user links.

1.4

Network management This section provides network management information for the 7360 ISAM FX system. Figure 1-9 shows how the 7360 ISAM FX system can be managed in a network.

1-14

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

1 — System overview Figure 1-9 7360 ISAM FX network management

ISAM EMS

Remote CT CLI (via Telnet) TL1 (via UDP-login)

CT

RS232

IACM

EMAN

LIM

LIM

xHub

LIM

Network Ports

Management Flow to cascaded ISAM 20768

The remote craft terminal (CT) uses TL1 commands or command line interface (CLI) commands. TL1 is used for pre-provisioning of the NT cards. CLI is used to manage both the xHub subsystem and the IACM. Figure 1-10 shows the management topology for the 7360 ISAM FX. Figure 1-10 7360 ISAM FX management topology

EMS TL1 Gateway TL1 Terminal (e.g. AMS 5520) SNMPv2 or SNMPv3

UDP

SNMP agent

ISAM

SSH

TL1 agent

TL1 CT RS232

CLI Terminal SSH

Telnet

CLI CT RS232

CLI agent

Debug Terminal UDP

Debug agent

20767

The NT controller and the xHub subsystem each contain a separate SNMP agent. These can be managed using an element management station (EMS), such as the Alcatel-Lucent 5520 AMS. It is also possible to use a local TL1 or CLI craft terminal on the NT card to manage the LT cards. An integrated CLI approach is implemented on the NT card using a CLI agent. This agent implements CLI commands for the NT controller / LIMs and the xHub subsystem. However, there is no semantic integration. Table 1-9 shows an overview of the involved managers.

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

1-15

1 — System overview Table 1-9 Manager overview Type

Description

EMS

Element management system (EMS) based on SNMP. The Alcatel-Lucent work station (5520 AMS) is commonly used.

CT

Craft terminal using TL1 commands or command line interface (CLI) commands.

Note 1 — External OAM VLAN:

The IHub subsystem supports in-band management. This happens through a dedicated VLAN, which must be configured (if different than 4093) on both the IHub subsystem as on the NT. Note 2 — VLAN 4094 is reserved for internal communication and cannot be used in any Ethernet network in which the 7360 ISAM FX system is deployed.

1.5

Equipment management This section describes the 7360 ISAM FX general equipment practice including CO equipment management, SyncE support, IWF capabilities, Ethernet frame size, dimensioning information, and OLT service and system capacity. The NE equipment practice type does not have to be explicitly planned by the operator, but is auto-planned by the NT at startup, depending on the detected type. At the same time, the NT will auto-plan the maximum number of racks supported by this equipment practice. The following 7360 ISAM FX type is defined:

• LNWW: large new equipment practice worldwide market (6 racks, 4 shelves per rack) Shelves are automatically planned upon detection. The operator can control the administrative state of a shelf (lock/unlock). The NE manages different types of cards. A complete overview of all supported card types in each type of shelf is in the chapter 2 “Shelves”. Card planning is supported for all types of cards, including the appliques. For LSMs, the operator can control the administrative state (lock/unlock).

CO equipment management CO equipment only supports configurations consisting of a single rack and shelf.

ONT management For more information about the ONT management, see System Description for FD 100/320Gbps NT and FX NT.

1-16

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

1 — System overview

1.6

Card capabilities and dimensioning This section provides an overview of:

• • • • • •

dimensioning information for the NT cards; see Table 1-10 SyncE support on NT cards and NTIO cards; see Table 1-11 the IWF capabilities of the LT cards per forwarding type; see Table 1-12 Ethernet frame size; see Table 1-13 dimensioning information of the LT cards per forwarding type; see Table 1-14 GPON-specific dimensioning; see Table 1-15

NT card dimensioning Table 1-10 lists the dimensioning for the NT cards and their variants. Table 1-10 NT card dimensioning Description

FANT-F

Throughput

480 Gbps

Maximum number of MAC addresses

(FDB)(1)

128 k

Maximum number of IP interfaces ARP table size

Maximum number of IP routes:

512 IPv4

16 k

IPv6

8k

IPv4 IPv6

FIB

16 k

RIB

16 k

FIB

8k

RIB

8k

Maximum number of L2 filters

512(2)

Maximum number of L3 filters

512

Maximum number of VLANs

4k

Maximum number of cross-connects

4k

Maximum number of ONTs

16

Maximum number of UNIs

19584

Maximum number of VLAN ports

103680

Maximum number of CC VLAN

49152

Maximum number of (active) MC streams

2k

Maximum number of L2-terminated VLAN

3072

L2 frame size (in bytes)

2048

External interfaces

1 x El. GE 4 x 1/10 GE

BITS in/out ports

1/1

SyncE input/output

4/4

(1 of 2)

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

1-17

1 — System overview

Description

FANT-F

IEEE1588 slave for frequency synchronization

Y

(2 of 2) Notes (1) A number of MAC addresses are always used by the system for internal purposes. (2) The same resource is shared for L2 filters and L3 filters. So, the maximum cannot be obtained for both at the same time.

SyncE support Table 1-11 lists the port applicability of the SyncE NTR functionality for clock extraction (in) and generation (out). Table 1-11 Faceplate port applicability for SyncE Card

Port

SyncE in support

SyncE out support

FANT-F

X1

1 GE and 10 GE

1 GE and 10 GE

X2

1 GE and 10 GE

1 GE and 10 GE

X3

1 GE and 10 GE

1 GE and 10 GE

X4

1 GE and 10 GE

1 GE and 10 GE

IEEE 1588v2 PTP support The IEEE 1588v2 precise time protocol provides an upgraded architecture to improve syncronization accuracy and allow precise ToD information to be distributed within the NT and LT cards in a 7360 ISAM FX shelf. The ToD serial output and 1PPS signals are processed by the NT cards and are distributed to the LT cards through the backplane signals of the 7360 ISAM FX system to allow the collection of precise ToD information that can be measured on both the ToD/1PPS interface on the NT card, and on the system backplane.

IWF capabilities Table 1-12 lists the IWF capabilities of the LT cards. See Table 1-4 for an overview of the supported LT cards. Table 1-12 IWF capabilities Feature

L3

L3 GPON

NELT-B UNI

NNI

ATM AAL5 encapsulation type LLC/SNAP bridged (IPoE and PPPoE)

Y







LLC/SNAP routed (IPoA)

Y







LLC/NLPid (PPPoA)

Y







(1 of 3)

1-18

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

1 — System overview

Feature

L3

L3 GPON

NELT-B UNI

NNI

VC Mux bridged (IPoE and PPPoE)

Y







VC Mux routed (IPoA)

Y







VC Mux PPPoA (PPPoA)

Y







Auto-detect IP (between LLC/SNAP bridged and routed)

Y







Auto-detect PPP (between LLC/SNAP bridged, VC Mux bridged and LLC-NLPID, VC Mux PPPoA)

Y







Auto-detect IP+PPP

Y







Auto-detect PPPoA (between LLC-NLPID and VC Mux PPPoA)

Y







Reception of untagged packets

Y



Y

Y

Reception of combination of untagged and priority-tagged packets

Y



Y

Y

Reception of single-tagged packets

Y

Y

Y

Y

Reception of combination of untagged, priority-tagged, single-tagged packets

Y

Y

Y

Y

Port-based default VLAN for untagged/priority-tagged (if applicable) packets

Y

Y

Y

Y

Port- and protocol-based default VLAN for untagged/priority-tagged packets of the IpoE protocols

Y

Y

Y

Y

Port- and protocol-based default VLAN for untagged/priority-tagged packets of the PPPoE protocols

Y

Y

Y

Y

Priority-bit re-marking and mapping table for tagged/priority-tagged packets

Y

Y

Y

Y

RB mode: protocol filter (set of Ethertypes) for upstream traffic in VLANs in (PPPoE and IpoE)

Y

Y

Y

Y

RB mode Ethernet packet types: Ethernet II encap on Ethernet

Y

Y

Y

Y

RB mode Ethernet packet types: LLC/SNAP on Ethernet

Y

Y

Y

Y

CC mode: transparently pass all encapsulations (for example, PPPoE and IpoE)

Y

Y

Y

Y

CC mode: protocol filter

Y

Y



Y

CC mode: IPoA to IPoE CC

Y







VLAN stacking (S-VLAN CC and S-VLAN/C-VLAN CC)

Y

Y

Y

Y

VLAN stacking (S-VLAN/C-VLAN residential bridge)









QoS-aware CC

Y







ARP: enabling/disabling broadcast

Y

Y

Y



802.1X authentication

Y

Y

Y



Encapsulation autodetect

Bridged encapsulation Ethernet packet formats

Packet processing

L2 Forwarding

L2 Forwarding user access protocols

(2 of 3)

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

1-19

1 — System overview

Feature

L3

L3 GPON

NELT-B UNI

NNI

DHCP option 82 insertion

Y

Y

Y



PPPoE relay tag

Y

Y

Y



PPPoA-PPPoE relay

Y







Multicast services access control

Y

Y

Y



Multicast services resource control

Y

Y

Y

Y

L3 Forwarding IPoE

(1)

Y

Y

Y



IPoA

(1)

Y

Y

Y



Y

Y

Y



802.1X authentication

Y



Y



ARP proxy user side for IPoE

Y

Y





DHCP relay

Y



Y



CAC profile

Y

Y

Y

Y

Association of QoS profiles to ports

Y

Y

Y

Y

Association of QoS profiles to port-VLAN associations

Y

Y

Y

Y

Sub-flow counters



Y





VLAN termination (at network side), forwarding at Layer 3 L3 Forwarding user access protocols

QoS

(2)

(3 of 3) Notes (1) IP aware bridge is only supported on L3 LT cards with 1GE NT interface; not on L3 LT cards with 2.5GE NT interface GPON LT cards and NELT-B (2) Support policing on bridge port on L2.

Ethernet frame size Table 1-13 lists the supported Ethernet frame size for the LT cards. Table 1-13 Ethernet frame size for LT cards

1-20

LT card

Encapsulation

Frame size (bytes)

P2P Ethernet

NELT-B UNI (with FCS)

1976

NELT-B NNI (with FCS)

2048

OLT

FGLT-A (with FCS)

2000

OLT

NGLT-A (with FCS)

2000

OLT

NGLT-C (with FCS)

2000

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

1 — System overview

Dimensioning of the LT cards Table 1-14 lists the dimensioning information for the LT cards. See Table 1-4 for an overview of the supported LT cards. Table 1-14 LT card dimensioning information Feature

L3

L3 GPON

NELT-B UNI

NNI





General Maximum number of PONs

(2)



8 16

Maximum number of UNIs



4096





Maximum number of FE ports per card





36

36

Maximum number of GE ports per card





36

36

Maximum number of UNI port type (FE) per card





36



Maximum number of UNI port type (GE) per card





36



Maximum number of NNI port type (FE) per card







36

Maximum number of NNI port type (GE) per card







36

Maximum number of CC VLAN

768

11 520

4608

4608

Maximum number of RB VLAN

768

1296

1296

1296

Maximum number of VLAN per PVC

16

8





Maximum number of port-VLAN associations per LT

384

11 520

144

4608

Maximum number of VLAN port per UNI (FE/GE)





8



Maximum number of VLAN port per NNI (FE/GE)







256

Maximum number of MAC addresses per VLAN port

64

64





Maximum number of MAC addresses per UNI





64



Maximum number of MAC addresses per NNI







3072

Maximum number of MAC addresses per LT (including static)

1024

16 K(1)

2304

32768

Maximum number of user IP addresses per LT (including static)

384

8K





Average number of IPv4 subnets or addresses per card (=Average IP anti-spoofing entries, full/32 IP address or subnet, per card





288

0

Maximum number of IPv4 hosts per card





288

0

(1 of 2)

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

1-21

1 — System overview

Feature

L3

L3 GPON

NELT-B UNI

NNI

Maximum number of IPv6 subnets or addresses per UNI





16

0

Maximum number of IPv6 subnets or addresses per VLAN port





4

0

Maximum number IPv6 host addresses per card





288

0

Maximum number of VRFs per LT

128

N\A





Maximum number of simultaneous multicast channels per LT

1024

1024

1024

1024

Maximum number of multicast groups per user

100

100

100

1024

Maximum number of multicast VLANs

128

64





Maximum number of 802.1x sessions per PON



288





Maximum number of 802.1x sessions per UNI





1



Maximum number of 802.1x sessions per card



2304

36



Multicast dimensioning

802.1x

(2 of 2) Notes (1) A few MAC addresses are used by the system for internal purposes. (2) Dependant on variant of LT card; NGLT-A/NGLT-C:8, FGLT-A:16.

ISAM OLT service and system capacity This section provides information about the 7360 ISAM FX service and system capacities, and ISAM OLT performance, distance, and connection capacities. Service and system capacities

Table 1-15 lists dimensioning information specific to the GPON functionality. Table 1-15 GPON-specific dimensioning information

1-22

Feature

L3 GPON

Maximum number of ONT per PON

128

Maximum number of UNIs per PON

288

Maximum number of TCONTs per PON

1024

Maximum number of GEM ports per PON

2048

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

1 — System overview

ISAM OLT performance and distance

The P-OLT provides performance and distance capacity of 2.488 Gb/s downstream and 1.244 Gb/s upstream, within a 30 km (18.6 mi) span, for all NGLT cards. The optical link budget is defined by both loss and bandwidth characteristics. The loss characteristic is determined by the difference between the optical transmitter and optical receiver for each direction, and is typically 28 dB. The bandwidth characteristic is determined by the maximum link distance parameter of each OLT and ONT transmitter specification, and is limited by the smaller of the upstream and downstream values. ISAM OLT connection capacities

The ISAM OLT can accommodate a maximum of 16 LT cards. The number of ports depends on the LT card used. Table 1-16 describes the total number of ports per LT card. Table 1-16 Total number of ports per LT card

1.7

Card type

Number of ports per card

Totalnumber of ports

FGLT-A

16

256

NGLT-A

8

128

NGLT-C

8

128

NT redundancy support Four levels of redundancy are supported:

• • • •

link redundancy equipment redundancy subscriber line redundancy application redundancy

NT redundancy implements link redundancy and equipment redundancy in a decoupled architecture, which results in the following redundancy cases:

• only link protection: • • • •

single NT, active-standby, or load-sharing uplinks combined NT and link protection, no NTIO: dual active/standby NT, with direct uplink or link set decoupled NT and link protection, single NTIO: dual active/standby NT, NTIO card with link switches NT protection, passive link protection, no NTIO: single, active-standby or load sharing uplinks subtending system protection

Table 1-17 lists the hardware modules that are ready for NT redundancy support. Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

1-23

1 — System overview Table 1-17 NT Redundancy support-ready hardware modules Type

Module

Shelf

NFXS-D NFXS-E NFXS-F

NT cards

FANT-F

LT cards

NELT-B NGLT-A NGLT-C FGLT-A

1.8

CLEI codes This sections provides the currently available CLEI codes. Table 1-18 lists the cards and fan units for which CLEI codes are available. Caution — The CLEI code changes whenever an item change (that is, an adaptation to a card) occurs.

The latest status of these CLEI codes is always available on the following website: https://codecenter.commonlanguage.com/applogin.asp?app=clei_inq uiry An account is required before the CLEI database can be accessed. Table 1-18 CLEI codes Mnemonic

Variant

CLEI code

CPR

Bar code

AFAN-E

3FE 65060 AA

VAUCAJ86AA

072AXJ

178692

AFAN-H

3EC 37533 NB

VAUCAE2KAA

070LXX

154967

AFAN-X

3FE 64994 AA

VAUCAJ56AA

072ARC

178361

FANT-F

3FE 53701 BD

VAI2AHVNAA

072DJP

182107

FGLT-A

3FE 66721 AA







NELT-B

3FE 62543 AA

VAUCAJ36AA

072AEY

177909

NFXS-D

3FE 65209 BA

VAMZ600BRA

215138

463997

NFXS-E

3FE 64936 BA

VAMZ400BRA

215136

463993

NFXS-F

3FE 64991 BA

VAMZ500BRA

215137

463996

NGFC-G

3FE 65676 AA

VAUCAK26AA





NGFC-H

3FE 65675 AA

VAUCAK36AA





(1 of 2)

1-24

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

1 — System overview

Mnemonic

Variant

CLEI code

CPR

Bar code

NGLT-A

3FE 64279 AA

VAI2AFHDAA

070YVT

175498

NGLT-C

3FE 67301 AA







(2 of 2)

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

1-25

1 — System overview

1-26

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

2 — Shelves

2.1 Overview

2-2

2.2 7360 ISAM FX shelves 2.3 Supported plug-in units 2.4 Dummy front panels

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

2-2 2-7 2-8

2-1

2 — Shelves

2.1

Overview This chapter provides information about the different 7360 ISAM FX shelves supported for ANSI.

2.2

7360 ISAM FX shelves This section provides general information about the 7360 ISAM FX shelf types, shelf configurations, NT redundancy, fan unit, baffles, and drip tray. The modular organization of the 7360 ISAM FX system allows a wide range of physical size and traffic capacity options. The basic building blocks of the 7360 ISAM FX system are the shelves. The 7360 ISAM FX system for R4.x is a one-shelf system. Daisy-chaining multiple shelves using extender cards is not supported. Multiple collocated shelves can be cascaded using the standard FE, GE, and 10 GE subtending links. In such a configuration, each shelf operates and is managed as a separate system.

Shelf types Table 2-1 lists the 7360 ISAM FX shelves supported. Table 2-1 7360 ISAM FX shelves supported Item

Shelves 7360 ISAM FX16

7360 ISAM FX8

7360 ISAM FX4

Code

3FE 65209 BA

3FE64936 BA

3FE-64991 BA

Mnemonic

NFXS-D

NFXS-E

NFXS-F

Dimensions

Width Height Depth

Can be mounted in:

529 mm

482.5 mm

482.5 mm

20.83 in.

19.00 in.

19.00 in.

622.5 mm

355 mm

222 mm

24.51 in.

13.98 in.

8.74 in.

max. 280 mm

278.3 mm

278.3 mm

11.02 in.

10.96 in.

10.96 in.

19 in. EIA standard racks

N

Y(1)

Y(1)

23 in. racks

Y(1)

Y(1)

Y(1)

Note (1)

Specific mounting kits must be used. See Table 2-3 for mounting kit requirements.

Figure 2-1 shows the 7360 ISAM FX-16 shelf. 2-2

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

2 — Shelves

Figure 2-2 shows the 7360 ISAM FX-8 shelf. Figure 2-3 shows the 7360 ISAM FX-4 shelf. Figure 2-1 7360 ISAM FX-16 shelf

Card cage area

02

03

04

05

BO N

D

I N G

07

08

NTA

Energy Hazard

A/70 FOR LT

NTIO

NTB

09

11

12

7360 ISAM FX-16

B/70 FOR LT

-48V 70A

10

ON

A R T H

OFF

ON

E

ESD

06

OFF

N594

I N T

01

General function and control unit

14

15

BAT A

MAJOR

BAT B

MINOR

ACO

16

PO

Fan unit

ALM

Power unit and cable connection area

13

CRITICAL

Energy Hazard

BITS INTERFACE NT-A NT-B

TIME OF DAY

1 Hz-PULSE RING TIP FRAME GND

CRAFT PORT

TB

1-1

-4

T A BA 8V TB

1-2

TN TR BA

A TB

1-3

TN TR BA

B TB

1-4

-4

CO ALARMS

T B BA 8V

22120

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

2-3

2 — Shelves

04

05

06

07

08

Figure 2-2 7360 ISAM FX-8 shelf

NTB NTIO NTA N594

7360 ISAM FX-8

B-40A

Energy Hazard

Alarms

GND NTB

Remote Craft

BITS

External Alarms

FAN

Critical Major Minor

A-40A NTA

7360 ISAM FX-8

01

02

03

Card cage

BAT A BAT B

ACO

General facilities card

Fan unit 21957

02

03

04

Figure 2-3 7360 ISAM FX-4 shelf

NTIO NTA

7360 ISAM FX-4

NTB

01

Card cage

External Alarms

BITS

TOD/IHZ

Remote Craft

N594

7360 ISAM FX-4

NTA GND NTB

General facilities card

BAT A BAT B FUSE A B 1 2 3

Critical Alarms Major ACO Minor

FAN

Fan unit 22436

Shelf configurations Table 2-2 lists the shelf configurations.

2-4

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

2 — Shelves Table 2-2 Shelf configurations Configuration

7360 ISAM FX-16

7360 ISAM FX8

7360 ISAM FX4

Maximum number of LT cards

16

8

4

Maximum number of NT cards

2

2

2

Maximum number of NTIO cards

1 (optional)

1 (optional)

1 (optional)

The following figures show the general layout and the slot numbering for the 7360 ISAM FX shelves: Figure 2-4 shows the 7360 ISAM FX-16. Figure 2-5 shows the 7360 ISAM FX-8. Figure 2-6 shows the 7360 ISAM FX-4. Figure 2-4 Shelf configuration of 7360 ISAM FX-16

LT LT LT LT LT LT LT LT NT NTIO NT LT LT LT LT LT LT LT LT 1 2 3 4 5 6 7 8 A B 9 10 11 12 13 14 15 16

CBs, LEDs and switches Fan unit Connectors 22131

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

2-5

2 — Shelves Figure 2-5 Shelf configuration of 7360 ISAM FX-8 LT 8 LT 7 LT 6 LT 5 LT 4 LT 3 LT 2 LT 1 NT B

FAN

NT I/O NT A NGFC-H 21959

Figure 2-6 Shelf configuration of 7360 ISAM FX-4 LT 4 LT 3 LT 2 LT 1 NT B

FAN

NT I/O NT A NGFC-G 22406

NT redundancy The protection scheme for NT redundancy is 1+1 (active/active) in the data plane, and 1:1 (active/standby) in the control and management plane.

Fan unit One fan unit provides forced air cooling in the shelf. The fan unit is a field-replaceable unit in the shelf fan area and plugs directly into the backplane. The fan unit can be equipped with a fan filter.

Shelf mounting kits The mounting kits required for installation of 7360 ISAM FX-16 shelves are included with the shipment. The number of kits provided depends on the rack mounting configuration required, with either one or two shelves. Baffle kits, mounting bracket kits, and the required screws are all included. Specific mounting kits may be required for installation of the 7360 ISAM FX-8 and 7360 ISAM FX-4 shelves, depending on the rack mounting configuration.

2-6

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

2 — Shelves

Table 2-3 describes the mounting options and mounting kits available. See the 7360 ISAM FX Hardware Installation Manual for more information. Table 2-3 Mounting options/kits for 7360 ISAM FX shelves Type of rack / mount

7360 ISAM FX-4

7360 ISAM FX-8

19 in. EIA rack with horizontal mount

Shelf mounting kit optional

Shelf mounting kit optional

Includes:

Includes:





• 23 in. rack with horizontal mount

mounting brackets -not required mounting screws -required



mounting brackets -not required mounting screws -required

Shelf mounting kit required

Shelf mounting kit required

Includes:

Includes:







mounting brackets -required mounting screws -required



mounting brackets -required mounting screws -required

Heat and fiber management baffle A heat and fiber management baffle is installed with the 7360 ISAM FX-16 shelf for safety protection from heat, possible flame spread, and loose particles that may cause damage to equipment. Factory-installed fiber optic cabling ring-guides are used for proper fiber optic cable handling. See Figure 2-7. Figure 2-7 Heat and fiber management baffle for 7360 ISAM FX-16

22373

2.3

Supported plug-in units Table 2-4 lists the supported plug-in units in the 7360 ISAM FX shelves.

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

2-7

2 — Shelves Table 2-4 Supported plug-in units in 7360 ISAM FX shelves Slot

Plug-in Unit

Description

NTA

FANT-F

480 Gbps NT card

NTB

FANT-F

480 Gbps NT card

LT slot

NELT-B

36-line Ethernet (FE/GE) LT card

NGLT-A

GPON LT card with 8 GPON interfaces

NGLT-C

GPON LT card with 8 GPON interfaces

FGLT-A

GPON LT card with 16 GPON interfaces

NGFC-G

GFC for 7360 ISAM FX-8 shelf

NGFC-H

GFC for 7360 ISAM FX-4 shelf

AFAN-H NB

Fan unit for 7360 ISAM FX-16 shelf

AFAN-E

Fan unit for 7360 ISAM FX-8 shelf

AFAN-X

Fan unit for 7360 ISAM FX-4 shelf

General facilities card

Fan area

Note — For more information about the plug-in units, see the relevant UDS. The mnemonics that are used are explained in Appendix A.

2.4

Dummy front panels This section describes the 7360 ISAM FX shelf dummy panels (filler plates) for NT cards, optical LT cards, and NTIO cards. Dummy front panels must be mounted on any unused slot of a shelf to ensure:

• EMC compliance • thermal compliance via a correct airflow in the shelf • safety by avoiding direct contact with backplane connectors When a slot is provisioned, the dummy front panel is replaced by the appropriate card and the cables are connected to the card.

For NT cards A dummy front panel must be used when the second NT card is not installed. Figure 2-8 shows the dummy front panel for an NT card.

2-8

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

2 — Shelves

XX XX XX XXXXXXX

Figure 2-8 Dummy front panel for NT card

22197

For optical LT cards A dummy front panel must be used when an LT card is not installed (NGLT-A, NGLT-C, FGLT-A). Figure 2-9 shows the dummy front panel for optical LT cards.

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

2-9

2 — Shelves Figure 2-9 Dummy front panel for optical LT card

Dust cap

22198

For NTIO card A dummy front panel must be used when the NTIO card is not installed. Figure 2-10 shows the universal dummy front panel for an NTIO card.

2-10

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

2 — Shelves Figure 2-10 Universal dummy front panel for NTIO card

22429

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

2-11

2 — Shelves

2-12

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

3 — Rack mounting configurations

3.1 Overview

3-2

3.2 Rack equipment

3-2

3.3 7360 ISAM FX-16 rack mounting configurations

3-3

3.4 7360 ISAM FX-8 rack mounting configurations

3-5

3.5 7360 ISAM FX-4 rack mounting configurations

3-8

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

3-1

3 — Rack mounting configurations

3.1

Overview This chapter describes the rack equipment and the supported rack mounting configurations for the following 7360 ISAM FX shelves:

• 7360 ISAM FX-16 • 7360 ISAM FX-8 • 7360 ISAM FX-4 Note 1 — See chapter 6 for part numbers. Note 2 — See 7360 ISAM FX Hardware Installation Manual for

more information about how to install the equipment.

3.2

Rack equipment This section briefly describes the 7360 ISAM FX rack equipment and assembly. The rack equipment can be delivered as a pre-assembled rack or in separate kits. The rack assembly includes a rack, shelves, accompanying fan units, baffles, and drip tray assembly kits. Each rack configuration is ordered with a specific ordering code. The 7360 ISAM FX-16 rack mounting configurations include the rack, however, the racks are optional for the 7360 ISAM FX-8 and 7360 ISAM FX-4 rack mounting configurations. See Chapter 6 for ordering information. Parts can also be delivered separately or in kits, where the assembly is done on site at the customer location. Table 3-1 lists the 7360 ISAM FX system rack equipment that can be used, dependent on the rack configuration required and currently supported. Table 3-1 7360 ISAM FX supported rack equipment Size of rack

Shelf apeture between rack uprights

EIA standard 19 in. rack

17.75 in. (450.9 mm)

23 in. rack

21.5 in. (546.1 mm)

For more information about 7360 ISAM FX equipment and the supported racks and rack mounting configurations, see the 7360 ISAM FX Hardware Installation Manual.

3-2

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

3 — Rack mounting configurations

3.3

7360 ISAM FX-16 rack mounting configurations This section describes the 7360 ISAM FX-16 rack mounting configurations. The 7360 ISAM FX-16 can be installed vertically in a 23 in. rack. Table 3-2 lists the supported rack configurations for the 7360 ISAM FX-16 shelves in a 23 in. rack. An example of a configuration is shown in Figure 3-1. Table 3-2 Rack mounting configurations for 7360 ISAM FX-16 FEMA code

3FE 66742 AA

Rack unit

23 in. rack vertical mount

SR 1

NFXS-D

NFXS-D

Fiber and heat baffle kit

Fiber and heat baffle kit

Left and right mounting brackets

Left and right mounting brackets

Fan 1 SR 2

Fan 2

3FE 66742 AB

AFAN-H

AFAN-H

(with fan filter)

(with fan filter)



NFXS-D



Fiber and heat baffle kit



Left and right mounting brackets



AFAN-H (with fan filter)

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

3-3

3 — Rack mounting configurations Figure 3-1 Rack mounting configurations for 7360 ISAM FX-16 (3FE 66742 AB) 22.3 21.5

CRAFT PORT

BITS INTERFACE NT-A NT-B

TIME OF DAY

BITS INTERFACE NT-A NT-B

TIME OF DAY

1 Hz-PULSE RING TIP FRAME GND

CO ALARMS

34 RU

CRAFT PORT

1 Hz-PULSE RING TIP FRAME GND

CO ALARMS

22732

3-4

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

3 — Rack mounting configurations

3.4

7360 ISAM FX-8 rack mounting configurations This section describes the 7360 ISAM FX-8 rack mounting configurations. The 7360 ISAM FX-8 can be installed:

• horizontally in an EIA standard 19 in. rack • horizontally in a 23 in. rack Note — A 19 in. seismic rack with a 17.5 in. shelf aperture between the uprights is not supported.

Table 3-3 lists the supported horizontal rack mounting configurations for 7360 ISAM FX-8 shelves. Table 3-3 Horizontal rack mounting configurations for 7360 ISAM FX-8 Rack unit (1)

19 in. EIA rack horizontal mount

23 in. rack horizontal mount

SR 1

NFXS-E

NFXS-E

Shelf mounting kit

Shelf mounting kit

Fan 1 SR 2

AFAN-E

AFAN-E

(with fan filter)

(with fan filter)



NFXS-E Shelf mounting kit

Fan 2



AFAN-E (with fan filter)

Note (1)

Although only two rack units are portrayed in this table, up to five rack units are supported.

Figure 3-3 shows the 7360 ISAM FX-8 horizontal rack mounting configurations in am EIA standard 19 in. rack.

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

3-5

3 — Rack mounting configurations Figure 3-2 Horizontal rack mounting configurations for 7360 ISAM FX-8 in an EIA standard 19 in. rack 18.312 17.750

03

04

05

06

07

08

35 RU

NTB NTIO NTA

7360 ISAM FX-8

01

02

8 RU

7360 ISAM FX-8

B-40A

Energy Hazard

Energy Hazzard

Alarms

NTA

External Alarms

GND NTB BITS

FAN

Critical Major Minor

A-40A

TOD/IHZ

Remote Craft

BAT A BAT B

ACO

22736

Figure 3-3 shows the 7360 ISAM FX-8 horizontal rack mounting configurations in a 23 in. rack.

3-6

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

3 — Rack mounting configurations Figure 3-3 Horizontal rack mounting configurations for 7360 ISAM FX-8 in a 23 in. rack 22.313 21.500

03

04

05

06

07

08

35 RU

NTB NTIO NTA

7360 ISAM FX-8

B-40A

Energy Hazard

Energy Hazzard

Alarms

NTA

GND NTB BITS

FAN

Critical Major Minor

A-40A

External Alarms

7360 ISAM FX-8

01

02

8 RU

TOD/IHZ

Remote Craft

BAT A BAT B

ACO

22734

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

3-7

3 — Rack mounting configurations

3.5

7360 ISAM FX-4 rack mounting configurations This section describes the 7360 ISAM FX-4 rack mounting configurations. The 7360 ISAM FX-4 shelf can be installed:

• horizontally in an EIA standard 19 in. rack • horizontally in a 23 in. rack Note — A 19 in. seismic rack with a 17.5 in. shelf aperture between the uprights is not supported.

Table 3-4 lists the supported horizontal rack mounting configurations for 7360 ISAM FX-4 shelves. Table 3-4 Horizontal rack mounting configurations for 7360 ISAM FX-4 Rack unit (1)

19 in. EIA rack horizontal mount

23 in. rack horizontal mount

SR 1

NFXS-F

NFXS-F

Shelf mounting kit

Shelf mounting kit

Fan 1 SR 2

Fan 2

AFAN-X

AFAN-X

(with fan filter)

(with fan filter)

NFXS-F

NFXS-F

Shelf mounting kit

Shelf mounting kit

AFAN-X

AFAN-X

(with fan filter)

(with fan filter)

Note (1)

Although only two rack units are portrayed in this table, up to seven rack units are supported.

Figure 3-5 shows the 7360 ISAM FX-4 horizontal rack mounting configurations in an EIA standard 19 in. rack.

3-8

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

3 — Rack mounting configurations Figure 3-4 Horizontal rack mounting configurations for 7360 ISAM FX-4 in an EIA standard 19 in. rack 18.312 17.750

NTIO

5 RU

NTA

7360 ISAM FX-4

NTB

01

02

03

04

38 RU

External Alarms

BITS

N594

7360 ISAM FX-4

NTA GND NTB

TOD/IHZ

Remote Craft

BAT A BAT B FUSE A B 1 2 3

Critical Alarms Major ACO Minor

FAN

22740

Figure 3-5 shows the 7360 ISAM FX-4 horizontal rack mounting configurations in a 23 in. rack.

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

3-9

3 — Rack mounting configurations Figure 3-5 Horizontal rack mounting configurations for 7360 ISAM FX-4 in a 23 in. rack 22.313 21.500

02

03

04

38 RU

NTIO NTA

7360 ISAM FX-4

NTB

01

5 RU

External Alarms

BITS

N594

7360 ISAM FX-4

NTA GND NTB

TOD/IHZ

Remote Craft

BAT A BAT B FUSE A B 1 2 3

Critical Alarms Major ACO Minor

FAN

22738

3-10

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

4 — Optical modules

4.1 Overview

4-2

4.2 Characteristics

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

4-2

4-1

4 — Optical modules

4.1

Overview This chapter describes the Alcatel-Lucent approved SFP and XFP optical modules for the 7360 ISAM FX.

4.2

Characteristics Table 4-1 describes the Alcatel-Lucent approved optical modules for the 7360 ISAM FX. See Chapter 6, Table 6-12 for part numbers and the cards that these modules support. Table 4-1 Characteristics of approved optical modules

Part number

Description

Wavelength (nm)

Operating case temperature range

Optical budget (dB)

Reach

Fiber

Bidi / uni

UDS(1)

1310

−40°C to 85°C

12

0.550 km

MM

Uni

DAAA

SM

Uni

SM

Bidi

SM

Bidi

SM

Bidi

Cat5



PAAA

Cat5



EAAA

Cat5



MM

Uni

SM

Uni

SM

Uni

SM

Uni

Fast Ethernet SFPs 3FE 25777 AA

FE-FX

−40°F to 185°F 3FE 25778 AA

FE-LX10

1310

−40°C to 85°C

0.342 mi 16

−40°F to 185°F 3FE 29194 AA 3FE 29194 BA 3FE 29195 AA 3FE 63343 AA

FE BX10-D FE BX10-D FE BX10-U 100Base-T

Tx: 1550

−40°C to 85°C

Rx: 1310

−40°F to 185°F

Tx: 1490

−40°C to 85°C

Rx: 1310

−40°F to 185°F

Tx: 1310

−40°C to 85°C

Rx: 1550

−40°F to 185°F



0°C to 70°C

15 km 9.3 mi

14

10 km

FAAA

6.2 mi 14

10 km 6.2 mi

14

10 km 6.2 mi



32°F to 188°F

0.100 km 0.062 mi

Copper SFPs 3FE 28784 AA

1000Base-T



0°C to 85°C



32°F to 188°F 3FE 64927 AA

1000Base-T



−40°C to 85°C

0.10 km 0.06 mi



−40°F to 185°F

0.10 km 0.06 mi

Gigabit Ethernet SFPs 3FE 25773 AA

GE-SX

850

−40°C to 85°C

7

−40°F to 185°F 3FE 25774 AA

GE-LX

1310

−40°C to 85°C

11

−40°F to 185°F 3FE 25775 AA

GE-EX

1310

−40°C to 85°C

GE-ZX

1550

−40°C to 85°C

CAAA

10 km 6.2 mi

18

−40°F to 185°F 3FE 25776 AA

0.55 km 0.34 mi

40 km 24.9 mi

24

−40°F to 185°F

80 km 49.7 mi

(1 of 4)

4-2

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

4 — Optical modules

Part number

Description

Wavelength (nm)

Operating case temperature range

Optical budget (dB)

Reach

Fiber

Bidi / uni

UDS(1)

3FE 25771 AA

GE-YX CWDM (24 dB)

1471

−40°C to 85°C

22

62

SM

Uni

AAAA

1491

−40°F to 185°F

31

120

SM

Uni

10 km

SM

Bidi

SM

Bidi

SM

Bidi

SM

Bidi

Cat5



3FE 25771 AB 3FE 25771 AC

1511

3FE 25771 AD

1531

3FE 25771 AE

1551

3FE 25771 AF

1571

3FE 25771 AG

1591

3FE 25771 AH

1611

3FE 25771 CA 3FE 29549 CA

GE-VX CWDM (32 dB)

1471

−5°C to 85°C

1491

32°F to 185°F

3FE 29550 CA

1511

3FE 29551 CA

1531

3FE 29552 CA

1551

3FE 29553 CA

1571

3FE 29554 CA

1591

3FE 29555 CA

1611

3FE 25772 AA 3FE 25772 AB 3FE 28785 AA 3FE 25785 AB 3FE 28784 AA

GE-BX10-U GE-BX10-D GE-BX40-U GE-BX40-D 1000Base-T

Tx: 1310

−40°C to 85°C

Rx: 1490

−40°F to 185°F

Tx: 1490

−40°C to 85°C

Rx: 1310

−40°F to 185°F

Tx: 1310

−40°C to 85°C

Rx: 1550

−40°F to 185°F

Tx: 1550

−40°C to 85°C

Rx: 1310

−40°F to 185°F



0°C to 85°C 32°F to 188°F

9

GAAA

6.2 mi 9

10 km 6.2 mi

19

40 km 24.9 mi

19

40 km 24.9 mi



0.100 km

EAAA

0.062 mi

SFP+s (2 of 4)

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

4-3

4 — Optical modules

Part number

Description

Wavelength (nm)

Operating case temperature range

Optical budget (dB)

Reach

Fiber

Bidi / uni

UDS(1)

3FE 62600 AA

10 GE-R

1310

−40°C to 85°C

10

10 km

SM

Uni

MAAA

SM

Uni

SM

Uni

SM

Uni

MM

Uni

MM

Uni

SM

Uni

SM

Uni



Uni

XAAA

SM

Bidi

TAAA

SM

Bidi

SM

Bidi

SM

Bidi

SM

Bidi

−40°F to 185°F 3FE 62600 CA

10 GE-R

1310

−5°C to 85°C

6.2 mi 10

32°F to 185°F 3FE 62600 DA

10 GE-R

1310

0°C to 70°C

6.2 mi 10

32°F to 188°F 3FE 62600 EA

10 GE-R

1310

−40°C to 85°C

10 GE-R

850

0°C to 70°C

10

10 GE-R

850

−40°C to 85°C

11

10 GE-R

1550

−40°C to 85°C

11

10 GE-R

1550

−40°C to 85°C

0.3 km 0.19 mi

15

−40°F to 185°F 3FE 65832 AA

0.3 km 0.19 mi

−40°F to 185°F 3FE 65831 AA

10 km 6.2 mi

32°F to 188°F 3FE 63264 AA

10 km 6.2 mi

−40°F to 185°F 3FE 65608 AA

10 km

40 km 24.9 mi

24

−40°F to 185°F

80 km 53.3 mi

E1 SFPs 3FE 67231 AA

E1/T1 SFP



−40°C to 65°C



−40°F to 149°F

E1/T1: short haul 0.5 km 0.31 mi E1/T1: long haul 2.1 km 1.3 mi

Dual SFPs 3FE 65106 AA 3FE 65106 DA 3FE 65107 AA 3FE 65107 DA 3FE 66131 AA

GE-BX10-D GE-BX10-D FE-BX10-D FE-BX10-D

Tx: 1490

−40°C to 85°C

Rx: 1310

−40°F to 185°F

Tx: 1490

0°C to 70°C

Rx: 1310

32°F to 188°F

Tx: 1550

−40°C to 85°C

Rx: 1310

−40°F to 185°F

9

10 km 6.2 mi

9

10 km 6.2 mi

14

10 km 6.2 mi

Tx: 1550

0°C to 70°C

Rx: 1310

32°F to 188°F

14

10 km

FE-BX10-D

Tx: 1490

−40°C to 85°C

8 (FE)

10 km

GE-BX10-D

Rx: 1310

−40°F to 185°F

9 (GE)

6.2 mi

6.2 mi

(3 of 4)

4-4

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

4 — Optical modules

Part number

Description

Wavelength (nm)

Operating case temperature range

Optical budget (dB)

Reach

Fiber

Bidi / uni

3FE 66131 DA

FE-BX10-D

Tx: 1490

0°C to 70°C

9

10 km

SM

Bidi

GE-BX10-D

Rx: 1310

32°F to 188°F

1000BaseBX10

6.2 mi

SM

Bidi

SM

Bidi

SM

Bidi

SM

Bidi

SM

Bidi

UDS(1)

8 100BaseBX10 GPON SFP 3FE 53441 AA 3FE 53441 AC 3FE 53441 BA 3FE 53441 CC 3FE 53441 DA

Class B+, normal

Tx: 1490

−5°C to 70°C

Rx: 1310

23°F to 188°F

Class B+, normal

Tx: 1490

−40°C to 85°C

Rx: 1310

−40°F to 185°F

Class C+, normal

Tx: 1490

−5°C to 70°C

Rx: 1310

23°F to 188°F

Class B+ with OTDR

Tx: 1490

−40°C to 85°C

Rx: 1310

−40°F to 185°F

Class C+, with OTDR

Tx: 1490

−5°C to 70°C

Rx: 1310

23°F to 188°F

XG-PON1 OLT XFP

Tx: 1577

−5°C to +70°C

Rx: 1270

+23°F to +185°F

XG-PON1 ONU SFP+

Tx: 1577

−40°C to +85°C

Rx: 1270

−40°F to +185°F

TM1 SFP



−40°C to 70°C

28

30 km

RAAA

18.6 mi 28

30 km 18.6 mi

32

60 km 37.3 mi

28

30 km 18.6 mi

32

60 km 37.3 mi

XG-PON XFPs/SFPs 3FE 53971 AA

3FE 53972 AA

29 dB

40 km

SM

Bidi

29 dB

40 km

SM

Bidi

SM

Uni

YAAA

Other 3FE 66247 AA

28

WAAA

−40°F to 158°F (4 of 4) Note (1)

For more information about the characteristics of the SFP module, see UDS 3HH 01046 xxxx TQZZA, where xxxx is the document variant indicated in this column.

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

4-5

4 — Optical modules

4-6

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

Planning and ordering 5 — Planning the equipment 6 — Ordering the equipment

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

5 — Planning the equipment

5.1 Overview

5-2

5.2 Network considerations

5-2

5.3 Rack considerations

5-4

5.4 Shelf considerations

5-4

5.5 LT card considerations

5-5

5.6 NT card considerations

5-5

5.7 V-OLT and video coupler equipment considerations 5.8 Installation considerations 5.9 Power considerations

5-7

5-8

5.10 Maintenance considerations 5.11 Software licensing information 5.12 Documentation

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

5-5

5-8 5-8

5-8

5-1

5 — Planning the equipment

5.1

Overview This chapter provides planning considerations for ordering the 7360 ISAM FX equipment. Consider the following items when determining what you need:

• • • • • • • • •

5.2

required number and type of shelves rack requirements shelf power and mounting accessories shelf hardware kits and shelf add-on kits installation-related items, such as power and alarm equipment expansion configuration requirements software licensing documentation other requirements, such as MTA, ITSC, and BITS

Network considerations This section describes the 7360 ISAM FX network equipment considerations including system planning. The 7360 ISAM FX is implemented in an access network topology that extends optical access across the last mile of the communications network to the subscriber using fiber optic cable to provide services from the network to residential or business subscribers. The 7360 ISAM FX access network consists of four distinct equipment types:

• P-OLT, which includes the rack and shelves, and the corresponding NT and LT cards • V-OLT, which distributes RF overlay video signals across the GPON if the network provider chooses this method for providing video services • WDM, which is only required to support the V-OLT, and is used to mix and separate the RF video signals to and from the optical fiber going toward ONUs. • ONU, which is located at the subscriber premises as distributed end-points of the access network. This equipment implements the GPON protocol and adapts GPON PDUs to subscriber service interfaces. When planning the installation of the 7360 ISAM FX in an access network, consider the following requirements:

• type of services that will be provided to subscribers • number of ONUs required for each type of subscriber: • estimated number of single-family subscribers • estimated number of multi-dwelling subscribers • estimated number of SOHO subscribers • estimated number of business subscribers with CES (DS1 or E1) requirements • number of LT ports per LT card type • number of NT ports per NT card type • number of LT cards per shelf type: 16, 8, or 4 5-2

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

5 — Planning the equipment

• rack and rack configurations • number of shelves per rack configuration • system capacity restrictions System planning for indoor, outdoor, and business ONTs Use the following steps to calculate the system requirements to support the number of expected subscribers. 1

ONTs — Estimate the number of subscribers. One ONT is required for each subscriber. The number of indoor or outdoor ONTs equals the number of subscribers. The number of SOHO outdoor ONTs or business ONTs equals the number of subscribers.

2

LT ports— Divide the number of indoor or outdoor ONTs by the number of subscribers per LT port (for example, 32 or 64 based on a 1:32 or 1:64 split) to determine how many LT ports are required.

3

Microspan MS-R and MS-C — Determine the required units based on CES requirements of subscribers. See the appropriate Litespan and Microspan user documentation for more information.

4

LTs — Divide the number of LT ports required by the number of LT ports on the LT card to determine the total number of LT cards required.

5

Shelves — Divide the number of LT cards by 16, 8, or 4 to determine how many 7360 ISAM FX-16, 7360 ISAM FX-8, or 7360 ISAM FX-4 shelves are required, respectively.

6

Racks — Divide the number of shelves by the number of shelves per rack to determine the number of racks required.

System planning for modular ONTs Use the following steps to calculate the system requirements to support the number of expected subscribers. 1

Modular ONTs — Estimate the number of subscribers. Each modular ONT can support 12 subscribers. Divide the total number of subscribers by 12 to determine the number of modular ONTs required.

2

LT ports— Divide the number of modular ONTs by 8 to determine how many LT ports are required. The 7360 ISAM FX system typically supports 8 modular ONT units for each LT port.

3

LTs — Divide the number of LT ports required by the number of LT ports on the LT card to determine the total number of LT cards required.

4

Shelves — Divide the number of LT cards by 16, 8, or 4 to determine how many 7360 ISAM FX-16, 7360 ISAM FX-8, or 7360 ISAM FX-4 shelves are required, respectively.

5

Racks — Divide the number of shelves by the number of shelves per rack to determine the number of racks required.

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

5-3

5 — Planning the equipment

5.3

Rack considerations This section identifies the number of shelves that can be accommodated in a rack by rack size and rack mounting configuration; see Table 5-1. See section 6.2 for more information about rack mounting configurations. Table 5-1 Number of shelves per rack

Rack

Rack mounting configuration

7360 ISAM FX-16

7360 ISAM FX-8

7360 ISAM FX-4

23 in. rack

Horizontal mounting



4

7

Vertical mounting

2





Horizontal mounting



4

7

19 in. EIA standard rack

5.4

Shelf considerations This section identifies the 7360 ISAM FX shelf equipment required including references to ordering information. For each shelf, consider the number and type of:

• • • • • • •

NT units required LT slots that the shelf can accommodate (16, 8, or 4) LT units for the required types of subscriber services dummy front panels required for any unused slots in the shelf existing and required spare plug-in units SFP and XFP modules required for network and expansion links required cables, such as power harnesses

Table 5-2 lists the types of plug-in units including SFP and XFP modules, and cables for the 7360 ISAM FX shelves, and where to find ordering information. Table 5-2 Ordering plug-in units and cables for the 7360 ISAM FX shelves Type of orderable item

See section

Plug-in units

5-4

GFCs

Section 6.4

Fan units and fan filters

Section 6.5

NT units and dummy front panels

Section 6.6

LT units and dummy front panels

Section 6.8

SFP and XFP modules

Section 6.9

Cables

Section 6.10

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

5 — Planning the equipment

5.5

LT card considerations This section identifies the number of LT ports per LT card; see Table 5-3. Table 5-3 Number of LT ports per LT card LT card

Number of LT ports

NGLT-A

8 GPON ports

NELT-B

36 GE or FE channels 18 GE or FE SFP channels

5.6

NT card considerations This section identifies the number of NT ports per NT card; see Table 5-4. Table 5-4 Number of NT ports per NT card NT card

Number of NT ports

FANT-F

1 10Mbps, 100Mbps, or GE Base-T ports 4 10 GE SFP+ ports 1 ToD/1PPS RJ-45 connection port 1 10 MHz GPS SMA connection port 1 PPS SMA connection port 1 Local craft serial connection port

5.7

V-OLT and video coupler equipment considerations This section identifies the 7360 ISAM FX V-OLT and video coupler equipment, ordering, and installation considerations. If the V-OLT function is required, order both the V-OLT equipment and the video coupler equipment.

V-OLT equipment The V-OLT equipment consists of EDFAs that can accept 1550 nm wavelength optical signals and split the signals into multiple optical feeds onto the fiber path. Order the appropriate EDFAs. The V-OLT is supplied by third-party vendors. Contact your EDFA representative for information about your EDFA requirements.

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

5-5

5 — Planning the equipment

Video coupler equipment The video coupler equipment contains the following items:

• • • • • •

video coupler rack (standard 23 in. rack) three video coupler shelves, LGX compatible (VCSL) one fiber storage shelf (optional) video coupler WDM cassettes (VCW2), one per LT card two fiber management raceways, one on each side of the VCSLs optical jumper cables to connect LT cards and V-OLT to VCW2, and to provide output from VCW2 to ONUs

Ordering considerations

Consider the following when ordering the video coupler equipment:

• required cables and connection modules • installation-related items, such as power and alarm equipment normally procured from commercial sources Contact your Alcatel-Lucent sales representative for more information. Installation considerations

Consider the following when planning to install the WDM equipment in a CO location.

• Floor plan Determine the floor plan details:

• • • •

available space floor type overhead support management cable rack equipment

• Subscribers Determine the number of subscribers who require the radio frequency (RF) video services delivered through the V-OLT. • Optical fiber requirements Determine the optical fiber requirements for video lead from head-end equipment to the V-OLT. The following is required:

• number of connections • run lengths • connectors for termination Note — Alcatel-Lucent recommends that in the fiber distribution

network, APC-based or spliced connectors are used to avoid potential problems. In particular, splitters should be configured so that unused ports are terminated into APC-based connectors.

5-6

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

5 — Planning the equipment

5.8

Installation considerations This section describes the 7360 ISAM FX equipment installation considerations for required space, floor plan, alarms, access, power and ground cable, and optical fiber. The 7360 ISAM FX is typically installed in a CO environment. The following subsections describe items to consider when planning the installation of the 7360 ISAM FX in the CO.

Space Planners should determine the space requirement based on the number of shelves and racks required. If existing racks are to be used, verify space availability.

Floor plan Collect the following floor plan information:

• • • •

measurements of the available space, including height, width, and length floor type overhead support arrangement cable and rack requirement

Alarms Determine the alarm termination requirements. Determine the total number of alarms, and the number and types of connections required.

Access The remote craft port to perform operations and maintenance is connected to the front on the GFC panel.

Power and ground cable Determine the power and ground cable requirements. Collect information about the following:

• number of connections • run lengths and required wire gauge • termination requirements, such as lugs

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

5-7

5 — Planning the equipment

Optical fiber Determine the optical fiber requirements. Collect information on the following:

• number of connections • run lengths • termination requirements, such as connector types Note — Alcatel-Lucent recommends that in the fiber distribution

network, APC-based or spliced connectors are used to avoid potential problems. In particular, splitters should be configured so that unused ports are terminated into APC-based connectors.

5.9

Power considerations See the 7360 ISAM FX Safety Manual for the maximum power consumption per unit. Use the maximum power consumption figures to plan for power sizes required.

5.10

Maintenance considerations This section describes the 7360 ISAM FX maintenance considerations when ordering equipment. Order spare cards to support normal maintenance activities associated with the 7360 ISAM FX. The number of spares needed for each card type is determined by maintenance practices and equipment failure rates. Generally, a minimum of one spare card of each type used is recommended for CO maintenance personnel.

5.11

Software licensing information Software licensing information is included when you purchase the software kits and licenses. Contact your Alcatel-Lucent sales representative for current part numbers for software kits and licenses.

5.12

Documentation Customer documentation is available for download by registered customers from http://www.alcatel-lucent.com/myaccess. If you are a new user and require access to this service, contact your Alcatel-Lucent sales representative. See Table 1 in the Preface for a list of the documents in the documentation set for the 7360 ISAM FX.

5-8

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

6 — Ordering the equipment

6.1 Overview

6-2

6.2 Racks and mounting parts 6.3 Shelves 6.4 GFCs

6-3

6-6 6-7

6.5 Fan units and fan filters

6-8

6.6 NT card and dummy front panel

6-9

6.7 NTIO card and dummy front panel

6-10

6.8 LT cards and dummy front panels

6-10

6.9 Optical modules 6.10 Cables

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

6-11

6-13

May 2012

6-1

6 — Ordering the equipment

6.1

Overview This chapter provides part number information about the 7360 ISAM FX equipment. Table 6-1 lists the orderable items or collection of items, and identifies with a check mark the shelf to which an item or collection of items applies. Table 6-1 7360 ISAM FX equipment Type

Item

FX-16

Racks and mounting parts

7360 ISAM FX-16 mounting



7360 ISAM FX-8 mounting

FX-8



7360 ISAM FX-4 mounting Shelves

NFXS-D

✓ ✓

NFXS-E



NFXS-F GFCs



NGFC-H



NGFC-G Fan units and fan filters

FX-4



AFAN-H



AFAN-E



AFAN-X



NT card and dummy front panel

FANT-F







NT dummy front panel







NTIO card and dummy front panel

NTIO dummy front panel







LT cards and dummy front panels

NGLT-A







NELT-B







LT dummy front panel







Fast Ethernet SFPs







Gigabit Ethernet SFPs







SFP+s







E1 SFP







Dual SFPs







GPON SFPs







XG-PON XFPs/SFPs (XFP/SFP+)







Other







Optical modules

Note 1 — See the corresponding unit data sheet tor more information about a specific orderable item. Note 2 — The term dummy front panel is synonymous with the ANSI

term filler plate. 6-2

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

6 — Ordering the equipment

6.2

Racks and mounting parts This section identifies the parts and part numbers for rack-mounted parts. You can mount the 7360 ISAM FX-16 shelf in a 23 in. rack, and the 7360 ISAM FX-8 and 7360 ISAM FX-4 in a 23 in. or 19 in. EIA standard rack. The 6-2 lists the supported rack mounting configurations by shelf type and rack size. For more information about the rack mounting configurations, see 7360 ISAM FX Hardware Installation Manual. Table 6-2 Rack mounting configurations

Shelf

Rack size

Rack mounting configurations

7360 ISAM FX-16

23 in.rack

Vertical mounting with baffles

7360 ISAM FX-8

EIA standard 19 in. rack (17.75 in. I.D.)

Horizontal mounting

23 in. rack

Horizontal mounting with brackets

EIA standard 19 in. rack (17.75 in. I.D.)

Horizontal mounting

23 in. rack

Horizontal mounting with brackets

7360 ISAM FX-4

Table 6-3 identifies the part number for the 23 in. rack. Table 6-3 Racks Rack

Part number

23 in. rack

1AD 01412 0044

Table 6-4 lists the 7360 ISAM FX equipment orderable at the FEMA code level. The required mounting parts listed are included in the shipment under one part number. Table 6-4 FEMA level rack mounting parts for 7360 ISAM FX-16 Type

FEMA code (1)

Part

Part number

Quantity

7360 ISAM FX-16 mounting (1 of 2)

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

6-3

6 — Ordering the equipment

Type

FEMA code (1)

Part

Part number

Quantity

7360 ISAM FX-16 - rack with one shelf

3FE 66742 AA

23 in. rack

1AD 01412 0044

1

NFXS-D shelf

3FE 65209 BA

1

FX-16 left mounting bracket

3FE 54168 AA

1

FX-16 right mounting bracket

3FE 54168 AB

1

FX-16 fiber and heat baffle kit

3FE 67225 AA

1

12 × 24 1/2in. (12 mm) hex screws

1AD112490001

10

12 × 24 1/2in. (12.7 mm) hex screws

1AD008180005

14

Fan with fan filter

3EC 37533 NB

1

23 in. rack

1AD 01412 0044

1

NFXS-D shelf

3FE 65209 BA

2

FX-16 left mounting bracket

3FE 54168 AA

2

FX-16 right mounting bracket

3FE 54168 AB

2

FX-16 fiber and heat baffle kit

3FE 67225 AA

2

12 × 24 1/2in. (12 mm) hex screws

1AD112490001

20

12 × 24 1/2in. (12.7 mm) hex screws

1AD008180005

28

Fan with fan filter

3EC 37533 NB

2

7360 ISAM FX-16 - rack with two shelves

3FE 66742 AB

(2 of 2) Note (1)

See the 7360 ISAM FX Product Information Guide or the 7360 ISAM FX Hardware Installation Manual for FEMA level and other rack mounting configuration details.

Table 6-5 identifies the orderable mounting parts required for 7360 ISAM FX-8 and 7360 ISAM FX-4. The rack mounting parts are ordered separately. Table 6-5 Rack mounting parts for 7360 ISAM FX-8 and 7360 ISAM FX-4 Rack size

Rack mounting configuration

Part

Part number

Quantity

7360 ISAM FX-8 mounting (1 of 3)

6-4

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

6 — Ordering the equipment

Rack size

Rack mounting configuration

Part

Part number

Quantity

19 in. rack

Horizontal mounting of the 7360 ISAM FX-8 in an EIA standard 19 in. rack (17.75 in. I.D.)

NFXS-E

3FE 64936 BA

1

Horizontal shelf mounting kit (1)

3FE 67300 AA

1

12-24 x 12.7 mm screws

1AD002300017

16

Fan unit

3FE 65060 AA

1

Fan filter

3FE 64928 BA

1

NFXS-E

3FE 64936 BA

1

Horizontal shelf mounting kit

3FE 67300 AA

1

Left and right horizontal brackets

3FE 67313 AA

2

12-24 x 12.7 mm screws

1AD002300017

16

Fan unit

3FE 65060 AA

1

Fan filter

3FE 64928 BA

1

23 in. rack

Horizontal mounting of the 7360 ISAM FX-8 in a 23 in. rack

(2 of 3)

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

6-5

6 — Ordering the equipment

Rack size

Rack mounting configuration

Part

Part number

Quantity

NFXS-F

3FE 64991 BA

1

Horizontal shelf mounting kit (1)

3FE 67299 AA

2

12-24 x 12.7 mm screws

1AD002300017

16

Fan unit

3FE 64994 AA

1

Fan filter

3FE 64928 CA

1

NFXS-F

3FE 64991 BA

1

Horizontal shelf mounting kit

3FE 67299 AA

2

Left and right horizontal brackets

3FE 67312 AA

2

12-24 x 12.7 mm screws

1AD002300017

10

Fan unit

3FE 64994 AA

1

Fan filter

3FE 64928 CA

1

7360 ISAM FX-4 mounting 19 in. rack

23 in. rack

Horizontal mounting of the 7360 ISAM FX-4 in an EIA standard 19 in. rack (17.75 in. I.D.)

Horizontal mounting of the 7360 ISAM FX-4 in a 23 in. rack

(3 of 3) Note (1) Only kit screws required for horizontal installation in 19 in. rack.

6.3

Shelves This section lists the orderable variants of the 7360 ISAM FX shelf equipment; see Table 6-6. Table 6-6 Orderable 7360 ISAM FX shelves

Component

Mnemonic

Part number

7360 ISAM FX-16 shelf, 48 V only, excluding fan unit

NFXS-D

3FE 65209 BA

Includes required mounting brackets and screws

Description NFXS-D:

• • • • • • •

mounts vertically in a 23 in.rack allows for two NT cards and one NTIO card to be mounted in the middle slots of the card cage allows for flexible LT card mounting, meaning that several types of cards can be housed in the LT slots supports 48 V nominal power input voltage levels (± 20% tolerance) contains a field-replaceable fan unit and a field-replaceable fan filter has a built-in GFC (PDBP) supports 1+1 NT redundancy

(1 of 2)

6-6

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

6 — Ordering the equipment

Component

Mnemonic

Part number

7360 ISAM FX-8 shelf, 48 V only, including GFC and fan unit. (Fan filter ordered separately)

NFXS-E

3FE 64936 BA

Description NFXS-E:

• • • • • • • •

7360 ISAM FX-4 shelf, 48 V only, including GFC and fan unit. (Fan filter ordered separately)

NFXS-F

3FE 64991 BA

mounts horizontally in a 19 in. EIA standard rack, kit not required. Order screws separately. mounts horizontally in a 23 in. rack, with mounting kit that includes required mounting brackets and screws provides housing for associated interface units, which are plug-in units of 405 x 225 mm (15.94 in. x 8.86 in.) allows for two NT cards and one NTIO card to be mounted in the lower slots of the card cage allows for flexible LT card mounting, meaning that several types of cards can be housed in the LT slots holds a field-replaceable GFC holds a field-replaceable fan unit and a field-replaceable fan filter supports 1+1 NT redundancy

NFXS-F:

• • • • • • • •

mounts horizontally in a 19 in. EIA standard rack, kit not required. Order screws separately. mounts horizontally in a 23 in. rack, with mounting kit that includes required mounting brackets and screws provides housing for associated interface units allows for two NT cards and one NTIO card to be mounted in the lower slots of the card cage allows for flexible LT card mounting, meaning that several types of cards can be housed in the LT slots holds a field-replaceable GFC holds a field-replaceable fan unit and a field-replaceable fan filter supports 1+1 NT redundancy

(2 of 2)

6.4

GFCs This section lists the orderable variants of the GFCs used in the 7360 ISAM FX shelves; see Table 6-7. Note — The 7360 ISAM FX-16 shelf has a built-in GFC that is not field-replaceable.

Table 6-7 Orderable GFCs Component

Mnemonic

Part number

Description

GFC for the 7360 ISAM FX-8 shelf

NGFC-H

3FE 65675 AA

NGFC-H is the power interface part of the 7360 ISAM FX-8 shelf and acts as the interface for inter-rack routing of alarms toward the NT card, for user-defined alarms, as well as for the power-related alarms of the shelf.

(1 of 2)

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

6-7

6 — Ordering the equipment

Component

Mnemonic

Part number

Description

GFC for the 7360 ISAM FX-4 shelf

NGFC-G

3FE 65676 AA

NGFC-G is the power interface part of the 7360 ISAM FX-4 shelf and acts as the interface for inter-rack routing of alarms toward the NT card, for user-defined alarms, as well as for the power-related alarms of the shelf.

(2 of 2)

6.5

Fan units and fan filters This section describes the orderable variants of the fan units and fan filters for the 7360 ISAM FX shelves; see Table 6-8. Note — When installed in a shelf, a fan filter should be changed at least every 3 months depending on conditions.

Table 6-8 Orderable fan units and filters Component

Mnemonic

Part number

Fan with fan filter, 48 V, only for the 7360 ISAM FX-16 shelf

AFAN-H

For fixed speed: 3EC 37533 NB

Description (1)

AFAN-H provides forced air cooling in a 7360 ISAM FX-16 shelf, and has the following features:

• • • • • •

Fan for the 7360 ISAM FX-8 shelf (Fan filter ordered separately)

AFAN-E

3FE 65060 AA

contains eight fixed-speed fans supports nominal voltages: −48 V dc secured to the shelf by screws field-replaceable and can be hot-inserted connected to the shelf backplane via two 15-pin male D-SUB miniature connectors. equipped with fan filter for use in CO environment. This fan filter must be removed when the shelf is used in closed (cabinet-like) environments where such a filter is not applicable and where higher ambient temperatures (higher than 45°C) are expected.

AFAN-E provides forced air cooling in a 7360 ISAM FX-8 shelf, and has the following features:

• • • • • • • •

contains six wide-voltage range, temperature controlled, variable speed fans mounts in the 7360 ISAM FX-8 shelf fan area behind the fan unit cover supports nominal voltages: −48 V dc / −60 V dc contains a fan unit control card, which generates a common fan alarm toward the NT cards (via the NGFC-E) in case of fan failure and lights the fan alarm LED. secured to the 7360 ISAM FX-8 shelf with a screw field-replaceable and can be hot-inserted provides the space and guiding for a field-replaceable fan filter if the fan unit is equipped with fan filter, the fan unit is only suitable for a CO environment

(1 of 2)

6-8

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

6 — Ordering the equipment

Component

Mnemonic

Part number

Description

Fan for the 7360 ISAM FX-4 shelf (Fan filter ordered separately)

AFAN-X

3FE 64994 AA

AFAN-X provides forced air cooling in a 7360 ISAM FX-4 shelf, and has the following features:

• • • • • • • •

Fan filter for the 7360 ISAM FX-8



3FE 64928 BA/DA



Fan filter for the 7360 ISAM FX-4



3FE 64928 CA/EA



contains four wide voltage range, temperature controlled, variable speed fans mounts in the 7360 ISAM FX-4 shelf fan area behind the fan unit cover supports nominal voltages:−48 V dc / −60 V dc contains a fan unit control card, which generates a common fan alarm toward the NT cards (by way of the NGFC-F) in case of fan failure and lights the fan alarm LED secured to the 7360 ISAM FX-4 shelf with a screw field-replaceable and can be hot-inserted provides the space and guiding for a field-replaceable fan filter if the fan unit is equipped with fan filter, the fan unit is only suitable for a CO environment

(2 of 2) Note (1) The variable speed fan costs more, but is less noisy at room temperature than the fixed speed fan.

6.6

NT card and dummy front panel This section describes the orderable variant of the NT card and dummy front panel for the NT unit for the 7360 ISAM FX shelves; see Table 6-9. Table 6-9 Orderable NT card and NT dummy front panel

Component

Mnemonic

Part number

Description

480 Gb/s NT with ANSI T1 BITS, SyncE, and IEEE1588 for high-density/high-bandwidth applications, without SFPs (ANSI variant)

FANT-F

3FE 53701 BD

FANT-F card provides optical and electrical connections for Ethernet or Gigabit Ethernet network connectivity to a high-bandwidth IP services network

NT dummy front panel



3FE 65651 AA

Dummy front panel for the NT card must be used when the second NT card is not used in the shelf. The same dummy front panel can be used for all FX shelves including 7360 ISAM FX-16, 7360 ISAM FX-8, and 7360 ISAM FX-4.

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

6-9

6 — Ordering the equipment

6.7

NTIO card and dummy front panel This section describes the orderable variant of the NTIO card and the NTIO dummy front panel for the 7360 ISAM FX shelves; see Table 6-10. Note — The 7360 ISAM FX shelves do not use the NTIO card. A dummy front panel must be installed in the NTIO slot on the shelf.

Table 6-10 Orderable NTIO dummy front panel Component

Mnemonic

Part number

Description

NTIO card







NTIO dummy front panel



3FE 65651 BA

The same NTIO dummy front panel can be used for all FX shelves including 7360 ISAM FX-16, 7360 ISAM FX-8, and 7360 ISAM FX-4

6.8

LT cards and dummy front panels This section describes the orderable variants of the LT cards and LT dummy front panels for the 7360 ISAM FX shelves; see Table 6-11. Table 6-11 Orderable LT cards and LT dummy front panels

Component

Mnemonic

Part number

Description

8-port GPON LT card with enhanced (downstream) traffic management capabilities

NGLT-A

3FE 64279 AA

NGLT-A is a GPON LT card that can be installed in a 7360 ISAM FX shelf. The NGLT-A provides termination of eight GPON ports (2.488 Gb/s downstream and 1.244 Gb/s upstream). SFP GPON optical modules can be plugged into the NGLT-A card.

8-port GPON LT card with enhanced (downstream) traffic management capabilities

NGLT-C

3FE 67301 AA

NGLT-C is a GPON LT card that can be installed in a 7360 ISAM FX shelf. The NGLT-C provides termination of eight GPON ports (2.488 Gb/s downstream and 1.244 Gb/s upstream). SFP GPON optical modules can be plugged into the NGLT-C card.

P2P GE/FE LT card (36 lines), excluding SFPs

NELT-B

3FE 62543 AA

NELT-B is an FE/GE LT card that has up to 36 FE/GE optical ports for Ethernet access.

16-port GPON LT card with enhanced (downstream) traffic management capabilities

FGLT-A

3FE 66721 AA

FGLT-A is an GPON LT card that can be installed in a 7360 ISAM FX shelf. The FGLT-A provides termination of sixteen GPON ports (2.488 Gb/s downstream and 1.244 Gb/s upstream). SFP GPON optical modules can be plugged into the FGLT-A card.

LT dummy front panel



3FE 65005 AA

An LT dummy front panel must be installed in any unused LT slot.

6-10

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

6 — Ordering the equipment

6.9

Optical modules This section lists the orderable variants of the Alcatel-Lucent approved SFP and XFP modules. Table 6-12 identifies with a check mark the card to which an optical module applies. Table 6-12 Orderable optical modules Item

Part number

FANT-F

NELT-B

NGLT-A

NGLT-C

FGLT-A

Fast Ethernet SFPs FE-FX

3FE 25777 AA



FE-LX10

3FE 25778 AA



FE BX10-D

3FE 29194 AA



100Base-T

3FE 63343 AA

✓ Copper SFPs

1000Base-T

3FE 28784 AA



1000Base-T

3FE 64297 AA

✓ Gigabit Ethernet SFPs

GE-SX

3FE 25773 AA

GE-LX

3FE 25774 AA



GE-EX

3FE 25775 AA



GE-ZX

3FE 25776 AA



GE-YX CWDM (24 dB)

3FE 25771 AA



3FE 25771 AB



3FE 25771 AC



3FE 25771 AD



3FE 25771 AE



3FE 25771 AF



3FE 25771 AG



3FE 25771 AH



3FE 2571 CA



3FE 29549 CA



3FE 29550 CA



3FE 29551 CA



3FE 29552 CA



3FE 29553 CA



3FE 29554 CA



3FE 29555 CA



3FE 25772 AA



GE-VX CWDM (32 dB)

GE-BX10-U





(1 of 2)

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

6-11

6 — Ordering the equipment

Item

Part number

FANT-F

NELT-B

GE-BX10-D

3FE 25772 AB





1000Base-T

3FE 28784 AA





GE-BX40-U

3FE 28785 AA



GE-BX40-D

3FE 28785 AB



NGLT-A

NGLT-C

FGLT-A

SFP+s 10 GE-R

3FE 62600 AA

10 GE-R

3FE 62600 CA

10 GE-R

3FE 62600 DA



10 GE-R

3FE 62600 EA



10 GE-R

3FE 65608 AA



10 GE-R

3FE 63264 AA



10 GE-R

3FE 65831 AA



10 GE-R

3FE 65832 AA E1 SFP

2 × E1 SFP

3FE 67231 AA

✓ Dual SFPs

GE-BX10-D

3FE 65106 AA



GE-BX10-D

3FE 65106 DA



FE-BX10-D

3FE 65107 AA



FE-BX10-D

3FE 65107 DA

FE-BX10-D



3FE 66131 AA

(1)



3FE 66131 DA

(1)



GE-BX10-D FE-BX10-D GE-BX10-D GPON SFPs GPON SFP B+

3FE 53441 AA



GPON SFP B+

3FE 53441 AC







GPON SFP C+

3FE 53441 BA







GPON SFP B+ with OTDR

3FE 53441 CC







GPON SFP C+ with OTDR

3FE 53441 DA







XG-PON XFPs/SFPs XG-PON1 OLT XFP

3FE 53971 AA

XG-PON1 ONU SFP+

3FE 53972 AA Other

TM1 SFP

3FE 66247 AA



(2 of 2)

6-12

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

6 — Ordering the equipment Note (1)

This is a dual-rate compact SFP.

6.10

Cables This section describes the orderable cables required for the 7360 ISAM FX equipment installation. See your Alcatel-Lucent sales representative for details about the required cables.

Lugs and lug tool Alcatel-Lucent recommends the following crimp lugs and crimp lug tool:

• Input power lug: 2 AWG, 90C, Burndy YAZ2C-2TC14 or equivalent • 2 AWG 1/4 - 5/8 dual-hole copper lug long barrel peep, uses Burndy Die Code 10. See Burndy catalog for additional tool options. • Input power lug: 2 AWG, 90C, Thomas and Betts 54855BEPH or equivalent • 2 AWG 1/4 - 5/8 dual-hole copper lug long barrel peep, uses Thomas and Betts Die Code 33. See Thomas and Betts catalog for additional tool options.

CO external alarm cables Table 6-13 describes the CO external alarm cables that are orderable showing cable support per shelf type using a checkmark. Table 6-13 Orderable CO external alarm cables Item

Part number

7360 ISAM FX-16

50-pin micro DSUB connector (1)

3EM 22996 XX



50-pin micro DSUB connector, angled head

3EM 22996 AX

7360 ISAM FX-8

7360 ISAM FX-4





Note (1)

See your Alcatel-Lucent representative for the supported cable variant for 7360 ISAM FX-16.

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

6-13

6 — Ordering the equipment

6-14

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

A.

Mnemonics

A.1 Mnemonics overview

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

A-2

A-1

A. Mnemonics

A.1

Mnemonics overview Table A-1 describes the 7360 ISAM FX equipment mnemonics. Table A-1 Equipment mnemonics

A-2

Mnemonic

Description

AFAN-H

7360 ISAM FX-16 fan unit - version H

AFAN-E

7360 ISAM FX-8 fan unit - version E

AFAN-X

7360 ISAM FX-4 fan unit - version X

FANT-F

7360 ISAM FX NT card - version F

FGLT-A

7360 ISAM FX GPON LT card - version A

NELT-B

7360 ISAM FX 36-line FE/GE LT card - version B

NGLT-A

7360 ISAM FX GPON LT card - version A

NGLT-C

7360 ISAM FX GPON LT card - version C

NFXS-D

7360 ISAM FX-16 shelf - version D

NFXS-E

7360 ISAM FX-8 shelf - version E

NFXS-F

7360 ISAM FX-4 shelf - version F

NGFC-G

7360 ISAM FX GFC - version G

NGFC-H

7360 ISAM FX GFC - version H

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

Glossary

7360 ISAM FX

7360 Intelligent Services Access Manager FX A DSLAM that operates in a packet aggregation network. The 7360 ISAM FX enables deployment of triple-play services, such as video on demand, high-definition TV, and broadcast TV services for all subscribers simultaneously.

AFAN-E

7360 ISAM FX-8 fan unit Fan unit for the 8-slot shelf

AFAN-H

7360 ISAM FX-16 fan unit Fan unit for the 16-slot shelf

AFAN-X

7360 ISAM FX-4 fan unit Fan unit for the 4-slot shelf

AMS

Access Management System

ANSI

American National Standards Institute A nonprofit, nongovernmental body supported by over 1000 trade organizations, professional societies, and companies; ANSI was established for the creation of voluntary industry standards.

ATM

Asynchronous Transfer Mode

AWG

American Wire Gauge

BITS

Building Integrated Timing Source A clock that supplies a composite clock timing reference to all other clocks in a building over BITS clock cables

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

GL-1

Glossary

BPA

Backplane Assembly

BRAS

Broadband Remote Access Server

CAT 5e

Category 5 Ethernet

CB

Circuit Breaker

CBN

Common Bonding Network

CC

Cross-Connect

CDRH

Center for Devices and Radiological Health

CEC

Canadian Electrical Code

CEV

Controlled Environmental Vault A temperature- and humidity-controlled underground vault that houses components at a remote location

CFR

Code of Federal Regulation (U.S.)

CLEI

Common Language Equipment Identification A 10-character code used to identify telecommunications equipment. The 10-character structure, outlined in the Telcordia specification, specifies the basic product type, features, source document, and associated drawings and versions. A CLEI code is unique to a specific piece of equipment.

CLI

Command Line Interface

CO

Central Office

CPE

Customer Premises Equipment

CSA

Canadian Standards Association

CT

Craft Terminal

DSLAM

Digital Subscriber Line Access Multiplexer

EDG

Energy Dumping Ground

EIA

Electronics Industries Association

EMAN

Ethernet Metropolitan Area Network

EMC

Electromagnetic Compatibility EMC designates the ability of commodities to function normally in the electromagnetic environment (this ability is termed Electromagnetic Susceptibility [EMS]), and the ability not to generate unbearable electromagnetic interference to other devices and equipment in the same environment (this ability is termed Electromagnetic Interference [EMI]). These two abilities are collectively named EMC.

EMS

GL-2

Element Management System

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

Glossary

EMS manages the components of a network. ESD

Electrostatic Discharge ESD is the rapid discharge of static electricity from one electrically-charged conductor to another of a different potential. An electrostatic discharge can damage integrated circuits found in computer and communications equipment.

FANT-F

Combined NT unit version F

FCC

Federal Communications Commission (U.S.)

FDA

Food and Drug Administration

FE

Fast Ethernet

GE

Gigabit Ethernet Ethernet interface that runs at 1000 Mb/s

GFC

General Facilities Card

GPON

Gigabit Passive Optical Network GPON is a high performance PON technology based on the G.984 series of standards.

IBN

Isolated Bonding Network

ICES

Interference-Causing Equipment Standard (Industry Canada)

IEC

International Electrotechnical Commission

IHub

Intelligent Hub

IPTV

Internet Protocol Video/Television

ISAM

Intelligent Services Access Manager The Intelligent Services Access Manager is an xDSL access multiplexer that operates in a packet aggregation network. The ISAM enables deployment of triple-play services, such as video on demand, high-definition TV, and broadcast TV services for all subscribers simultaneously.

IWF

Interworking Function IWF provides seamless packet transmission between two protocol stacks. For example, IWF can connect an ATM endpoint with a frame relay endpoint using mappings between the two protocol stacks.

LAN

Local Area Network

LIM

Line Interface Module A network terminator for CEPT and T1.

LNWW

Large New Equipment Practise Worldwide

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

GL-3

Glossary

LP

A slot in the NE shelf where an applique is installed

LSM

Line Server Module A more generic term than LIM since it denotes both xDSL line interface modules and any other server application specific module.

LT

Line Termination Equipment that terminates the access line at the network end

NE

Network Element

NEBS

Network Equipment Building Standards

NEC

U.S. National Electrical Code

NELT-B

Ethernet line termination (LT) unit version B

NFXS-D

7360 ISAM FX 16-slot shelf

NFXS-E

7360 ISAM FX 8-slot shelf

NFXS-F

7360 ISAM FX 4-slot shelf

NGFC-G

7360 ISAM FX-4 power unit The power unit of the 4-slot shelf

NGFC-H

7360 ISAM FX-8 power unit The power unit of the 8-slot shelf

NGLT-A

GPON line termination (LT) board with Traffic Manager version A

NSP

Network Service Provider

NT

Network Termination

NTA

Network Termination A

NTB

Network Termination B

NTIO

Network Termination Input/Output

NTR

Network Timing Reference

OAM

Operation, Administration, and Maintenance

OLT

Optical Line Termination

ONT

Optical Network Terminal

ONU

Optical Network Unit

GL-4

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

Glossary

Equipment that provides voice, data, and video services and terminates the ISAM network at a subscriber location. ONUs provide services to a single family home, a business location, or a multi-dwelling residence, such as an apartment complex or condominium. Services can include POTS, high-speed Ethernet, IPTV, and RF video. OSP

Outside Plan

PBA

Printed Board Assembly

PDBP-C

7360 ISAM FX-16 power unit The power unit of the 7360 ISAM FX 16-slot shelf

P-OLT

Packet Optical Line Termination

PON

Passive Optical Network A fiber-based network that uses passive splitters to deliver signals to multiple users

POTS

Plain Old Telephone Service

PVC

Permanent Virtual Circuit A PVC is an ATM end-to-end logical connection between two user/network interfaces. A PVC may pass through several ATM switching NEs.

RAL

Restricted Access Location

RB

Residential-Bridge

RF

Radio Frequency

RFI

Radio Frequency Interference

Rx

Receive

SDH

Synchronous Digital Hierarchy

SELV

Safety Extra Low Voltage A circuit that has no direct connection to a primary power source, but derives its power from either a transformer, converter, or equivalent isolation device, or from a battery. The circuit is designed and protected so that under normal and single fault conditions, its voltages do not exceed a safe value.

SFP

Small Form-factor Pluggable SFP is a specification for a new generation of optical modular transceivers. The devices are designed for use with small form-factor connectors, and offer high speed and physical compactness. The devices are hot-swappable.

SNMP

Simple Network Management Protocol SNMP is a standard protocol for the management of entities in an IP local area network.

SONET

Synchronous Optical Network

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

GL-5

Glossary

SW

Control Software SW is an acronym used for IHub control software

SyncE

Synchronous Ethernet

TL1

Transaction Language 1

TNV

Telecommunications Network Voltage TNV is a secondary circuit for telecommunications networks. TNV complies with IEC 950.

ToD

Time of Day

Tx

Transmit

UL

Underwriters Laboratories, Inc.

VLAN

Virtual Local Area Network

VPLS

Virtual Private LAN Service A type of VPN in which a number of sites are connected in a single bridged domain over an IP network. The services can be from different locations, but they appear to be on the same LAN in VPLS.

VPN

Virtual Private Network

VPRN

Virtual Private Routed Network A network exhibiting at least some of the characteristics of a private network, even though it uses the resources of a public switched network.

VRF

Virtual Routing Forwarder A logical or virtual routing function with associated routing table that can be instantiated in a router capable of supporting IP VPN services

XFP

10-GE small form-factor pluggable An XFP module is a hot-swappable, protocol-independent transceiver, typically operating at 850 nm, 1310 nm, or 1550 nm, for 10 Gb/s SONET/SDH, fiber channel, gigabit Ethernet, 10 gigabit Ethernet and other applications. XFP was developed by the XFP Multi Source Agreement Group.

GL-6

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

Index

Numbers

D

7360 ISAM FX network topology, 1-2 ordering, 5-2 ordering plug-in units, 6-2 rack mounting configurations, 3-2 shelf configurations, 2-4 shelf types, 2-2 supported plug-in units, 2-7

dimensioning cards, 1-17 GPON, 1-22 documentation ordering, 5-8 dummy front panels, 2-8

B

equipment management, 1-16

baffles heat and fiber management, 2-7

C

F fan filters ordering, 6-8 fan units ordering, 6-8 feature descriptions new features, 1-6 fiber management baffles, 2-7 filler plates LT, 6-10 LT cards, 2-8 NT, 6-9 NT cards, 2-8

capabilities IWF, 1-17 cards dimensioning, 1-17 characteristics optical modules, 4-2 SFP, 4-2 CLEI codes, 1-24

Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

E

May 2012

IN-1

Index functional decomposition — ordering

functional decomposition system architecture, 1-7 FX-16 rack mounting configurations, 3-3 FX-4 rack mounting configurations, 3-8 FX-8 rack mounting configurations, 3-5

G general facilities cards; See GFC GFC ordering, 6-7 GPON dimensioning, 1-22

H heat management baffles, 2-7

I IHub system architecture, 1-14 installation mounting kits, 2-6 IWF capabilities, 1-17

L LT cards dummy panels, 2-8 filler plates, 2-8 ordering, 6-10

M management equipment, 1-16 network, 1-14 mounting kits shelf installation, 2-6

IN-2

N Network management, 1-14 network side network topology, 1-5 network termination units; See NT cards network topology 7360 ISAM FX, 1-2 network side, 1-5 subscriber side, 1-3 new features feature descriptions, 1-6 NT cards dummy panels, 2-8 filler plates, 2-8 ordering, 6-9 NT filler plate ordering, 6-9

O ONTs system planning for indoor ONTs, 5-3 system planning for modular ONTs, 5-3 system planning for outdoor ONTs, 5-3 optical modules approved, 4-2 characteristics, 4-2 ordering, 5-2 documentation, 5-8 fan filters, 6-8 fan units, 6-8 filler plate LT, 6-10 NT, 6-9 GFC, 6-7 LT cards, 6-10 LT filler plate, 6-10 NT filler plate, 6-9 NT unit, 6-9 plug-in units, 6-2 SFP modules, 6-11 software, 5-8 V-OLT equipment, 5-5 XFP modules, 6-11 May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

Index P — XFP module

P

system architecture functional decomposition, 1-7 IHub, 1-14 physical decomposition, 1-7 system planning for indoor ONTs, 5-3 for modular ONTs, 5-3 for outdoor ONTs, 5-3

P-OLT connection capacity specifications, 1-23 part numbers documentation, 5-8 fan filters, 6-8 fan units, 6-8 filler plate LT, 6-10 NT, 6-9 GFC, 6-7 LT cards, 6-10 LT filler plate, 6-10 NT filler plate, 6-9 NT unit, 6-9 SFP modules, 6-11 software, 5-8 XFP modules, 6-11 physical decomposition system architecture, 1-7 plug-in units, 2-7

T technical specifications P-OLT connection capacity, 1-23

V V-OLT equipment ordering, 5-5

X XFP module ordering, 6-11

R rack equipment, 3-2 rack mounting configurations, 3-2 FX-16, 3-3 FX-4, 3-8 FX-8, 3-5 redundancy support 1+1 NT, 1-23

S SFP characteristics, 4-2 SFP module ordering, 6-11 shelf configurations, 2-4 shelf types, 2-2 software ordering, 5-8 subscriber side network topology, 1-3 Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide

May 2012

IN-3

Index

IN-4

May 2012

Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide

Customer documentation and product support

Customer documentation http://www.alcatel-lucent.com/myaccess Product manuals and documentation updates are available at alcatel-lucent.com. If you are a new user and require access to this service, please contact your Alcatel-Lucent sales representative.

Technical Support http://support.alcatel-lucent.com

Documentation feedback [email protected]

© 2012 Alcatel-Lucent. All rights reserved. 3FE 54967 AAAA TCZZA Edition 01

View more...

Comments

Copyright ©2017 KUPDF Inc.