Download 3fe54967aaaatczza01_v1_7360 Isam Fx Olt r4.4, Ansi Product Information Guide...
ANSI PRODUCT INFORMATION GUIDE
Alcatel-Lucent 7360 INTELLIGENT SERVICES ACCESS MANAGER FX | RELEASE 04.04 ANSI PRODUCT INFORMATION GUIDE
3FE 54967 AAAA TCZZA Edition 01
Alcatel-Lucent Proprietary This document contains proprietary information of Alcatel-Lucent and is not to be disclosed or used except in accordance with applicable agreements. Copyright 2012 © Alcatel-Lucent. All rights reserved.
Alcatel-Lucent assumes no responsibility for the accuracy of the information presented, which is subject to change without notice. Alcatel, Lucent and the Alcatel-Lucent logo are registered trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. Copyright 2012 Alcatel-Lucent. All rights reserved. Disclaimers
Alcatel-Lucent products are intended for commercial uses. Without the appropriate network design engineering, they must not be sold, licensed or otherwise distributed for use in any hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life-support machines, or weapons systems, in which the failure of products could lead directly to death, personal injury, or severe physical or environmental damage. The customer hereby agrees that the use, sale, license or other distribution of the products for any such application without the prior written consent of Alcatel-Lucent, shall be at the customer's sole risk. The customer hereby agrees to defend and hold Alcatel-Lucent harmless from any claims for loss, cost, damage, expense or liability that may arise out of or in connection with the use, sale, license or other distribution of the products in such applications. This document may contain information regarding the use and installation of non-Alcatel-Lucent products. Please note that this information is provided as a courtesy to assist you. While Alcatel-Lucent tries to ensure that this information accurately reflects information provided by the supplier, please refer to the materials provided with any non-Alcatel-Lucent product and contact the supplier for confirmation. Alcatel-Lucent assumes no responsibility or liability for incorrect or incomplete information provided about non-Alcatel-Lucent products. However, this does not constitute a representation or warranty. The warranties provided for Alcatel-Lucent products, if any, are set forth in contractual documentation entered into by Alcatel-Lucent and its customers. This document was originally written in English. If there is any conflict or inconsistency between the English version and any other version of a document, the English version shall prevail.
When printed by Alcatel-Lucent, this document is printed on recycled paper.
Preface
This preface provides general information about the documentation set for the 7360 Intelligent Services Access Manager FX (7360 ISAM FX ) for ANSI.
Scope This documentation set provides information about safety, features and functionality, ordering, hardware installation and maintenance, CLI and TL1 commands, and software installation procedures.
Audience This documentation set is intended for planners, administrators, operators, and maintenance personnel involved in installing, upgrading, or maintaining the 7360 ISAM FX system.
Prerequired knowledge The reader must be familiar with general telecommunications principles.
Assistance and ordering phone numbers Alcatel-Lucent provides global technical support through regional call centers. Phone numbers for the regional call centers are available at the following URL: http://www.alcatel-lucent.com/myaccess For ordering information, contact your Alcatel-Lucent sales representative.
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
iii
Preface
Safety information See the 7360 ISAM FX Safety Manual for safety information. The following are examples of how special information is presented in this document. Danger — Danger indicates that the described activity or situation
may result in serious personal injury or death; for example, high voltage or electric shock hazards. Warning — Warning indicates that the described activity or situation
may, or will, cause equipment damage or serious performance problems. Caution — Caution indicates that the described activity or situation may, or will, cause service interruption.
Note — A note provides information that is, or may be, of special
interest.
Document conventions The following conventions are used in this documentation set.
Acronyms See the glossary for the expansion of acronyms used in this documentation set.
Release notes See the release notes (such as the customer release notes or emergency fix release note) issued for software loads of the 7360 ISAM FX before you install or use the 7360 ISAM FX. The release notes provide important information about the software load.
Documents Table 1 lists the documents that make up the 7360 ISAM FX documentation set.
iv
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
Preface Table 1 7360 ISAM FX documentation set for ANSI Title
Description
General documentation Product Information
Provides general system and ordering information for the 7360 ISAM FX
System Description for FD 100/320Gbps NT and FX NT
Provides conceptual information for the:
• •
Safety Manual
7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT
Provides general safety guidelines when handling, installing, or operating the 7360 ISAM FX equipment
Hardware documentation and unit data sheets FX Hardware Installation Guide
Describes the hardware installation for the 7360 ISAM FX equipment
UDS NFXS-D (FX-16)
Describes the 7360 ISAM FX-16 slot shelf
UDS NFXS-E (FX-8)
Describes the 7360 ISAM FX-8 slot shelf
UDS NFXS-F (FX-4)
Describes the 7360 ISAM FX-4 slot shelf
UDS NGFC-G
Describes the 7360 ISAM FX-4 general facilities card
UDS NGFC-H
Describes the 7360 ISAM FX-8 general facilities card
UDS FANT-F
Describes the NT card
UDS NELT-B
Describes the GPON LT board
(1)
version B
UDS NGLT-A
Describes the GPON LT board
(1)
version A
UDS dummy front panel FX NT
Describes the dummy front panel (filler plate) for the NT card
UDS dummy front panel FX LT
Describes the dummy front panel (filler plate) for the LT card
UDS AFAN-H
Describes the fan unit for the 7360 ISAM FX-16
UDS AFAN-E
Describes the fan unit for the 7360 ISAM FX-8
UDS AFAN-X
Describes the fan unit for the 7360 ISAM FX-4
TL1 documentation TL1 Commands and Messages for FD 100/320Gbps NT and FX NT
Describes the TL1 commands and messages for the:
• •
Operations and Maintenance Using TL1 for FD 100/320Gbps NT and FX NT
7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT
Provides task-oriented procedures using TL1 for operating and maintaining the:
• •
7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT
CLI documentation CLI Commands for FD 100/320Gbps NT and FX NT
Describes the CLI commands for the:
• •
7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT
(1 of 2)
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
v
Preface
Title
Description
Operations and Maintenance Using CLI for FD 100/320Gbps NT and FX NT
Provides task-oriented procedures using CLI for operating and maintaining the:
• •
7302 ISAM and the 7330 ISAM FTTN equipped with the 100Gpbs or the 320Gbps NT 7360 ISAM FX equipped with an FX NT
IHub System Basics, Management and OAM Guide for FD 100/320Gbps NT and FX NT
Describes the IHub system basics, system management and OAM (Operations and Maintenance)
IHub Interface Guide for FD 100/320Gbps NT and FX NT
Describes the IHub system interfaces
IHub QoS Guide for FD 100/320Gbps NT and FX NT
Describes the IHub quality of service
IHub Router Configuration and Protocols Guide for FD 100/320Gbps NT and FX NT
Describes the IHub router configuration and router protocols
IHub Services Guide for FD 100/320Gbps NT and FX NT
Describes the IHub services
MPLS Guide for FD 100/320Gbps NT and FX NT
Describes the IHub MPLS services
Software documentation Software Installation Guide
Describes the software management of the 7302 ISAM, the 7330 ISAM FTTN and the 7360 ISAM FX equipment
Software Upgrade and Migration Application Procedures
Provides instructions for using the automated tools for upgrading and migrating the software for the 7302 ISAM, the 7330 ISAM FTTN and the 7360 ISAM FX
(2 of 2) Note (1)
vi
The term “board” and “card” are both used in the 7360 ISAM FX documentation set. “Board” is used in reference to ETSI terminology, and “card” is used in reference to ANSI terminology.
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
Contents
Preface
iii
Scope ................................................................................................................... iii Audience ................................................................................................................... iii Prerequired knowledge ................................................................................................. iii Assistance and ordering phone numbers ........................................................................ iii Safety information........................................................................................................ iv Document conventions ................................................................................................. iv Release notes .............................................................................................................. iv Documents .................................................................................................................. iv
System and equipment overview 1—
System overview 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8
2—
Introduction ............................................................................................... 1-2 Feature descriptions.................................................................................... 1-6 System architecture .................................................................................... 1-7 Network management............................................................................... 1-14 Equipment management ........................................................................... 1-16 Card capabilities and dimensioning............................................................. 1-17 NT redundancy support............................................................................. 1-23 CLEI codes............................................................................................... 1-24
Shelves 2.1 2.2
1-1
2-1
Overview ................................................................................................... 2-2 7360 ISAM FX shelves................................................................................. 2-2
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
vii
Contents
2.3 2.4
3—
Rack mounting configurations 3.1 3.2 3.3 3.4 3.5
4—
Supported plug-in units............................................................................... 2-7 Dummy front panels ................................................................................... 2-8
Overview ................................................................................................... 3-2 Rack equipment ......................................................................................... 3-2 7360 ISAM FX-16 rack mounting configurations ............................................ 3-3 7360 ISAM FX-8 rack mounting configurations .............................................. 3-5 7360 ISAM FX-4 rack mounting configurations .............................................. 3-8
Optical modules 4.1 4.2
3-1
4-1
Overview ................................................................................................... 4-2 Characteristics............................................................................................ 4-2
Planning and ordering 5—
Planning the equipment 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.12
6—
6-1
Overview ................................................................................................... 6-2 Racks and mounting parts ........................................................................... 6-3 Shelves ...................................................................................................... 6-6 GFCs.......................................................................................................... 6-7 Fan units and fan filters .............................................................................. 6-8 NT card and dummy front panel .................................................................. 6-9 NTIO card and dummy front panel............................................................. 6-10 LT cards and dummy front panels .............................................................. 6-10 Optical modules........................................................................................ 6-11 Cables ..................................................................................................... 6-13
Mnemonics A.1
viii
Overview ................................................................................................... 5-2 Network considerations ............................................................................... 5-2 Rack considerations .................................................................................... 5-4 Shelf considerations .................................................................................... 5-4 LT card considerations ................................................................................ 5-5 NT card considerations................................................................................ 5-5 V-OLT and video coupler equipment considerations....................................... 5-5 Installation considerations ........................................................................... 5-7 Power considerations .................................................................................. 5-8 Maintenance considerations......................................................................... 5-8 Software licensing information ..................................................................... 5-8 Documentation ........................................................................................... 5-8
Ordering the equipment 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 6.10
A.
5-1
A-1
Mnemonics overview...................................................................................A-2 May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
Contents
Glossary
Index
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
ix
Contents
List of figures Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure
1-1 Basic 7360 ISAM FX network topology ........................................................ 1-3 1-2 Cascading topology mode .......................................................................... 1-4 1-3 Star topology mode ................................................................................... 1-4 1-4 Ring topology mode .................................................................................. 1-5 1-5 Network connections ................................................................................. 1-6 1-6 7360 ISAM FX functional components ......................................................... 1-8 1-7 7360 ISAM FX system components ............................................................. 1-8 1-8 7360 ISAM FX forwarding architecture ........................................................ 1-9 1-9 7360 ISAM FX network management ........................................................ 1-15 1-10 7360 ISAM FX management topology ..................................................... 1-15 2-1 7360 ISAM FX-16 shelf .............................................................................. 2-3 2-2 7360 ISAM FX-8 shelf ................................................................................ 2-4 2-3 7360 ISAM FX-4 shelf ................................................................................ 2-4 2-4 Shelf configuration of 7360 ISAM FX-16 ...................................................... 2-5 2-5 Shelf configuration of 7360 ISAM FX-8........................................................ 2-6 2-6 Shelf configuration of 7360 ISAM FX-4........................................................ 2-6 2-7 Heat and fiber management baffle for 7360 ISAM FX-16 .............................. 2-7 2-8 Dummy front panel for NT card.................................................................. 2-9 2-9 Dummy front panel for optical LT card...................................................... 2-10 2-10 Universal dummy front panel for NTIO card ............................................ 2-11 3-1 Rack mounting configurations for 7360 ISAM FX-16 (3FE 66742 AB)............. 3-4 3-2 Horizontal rack mounting configurations for 7360 ISAM FX-8 in an EIA standard 19 in. rack ........................................................................... 3-6 Figure 3-3 Horizontal rack mounting configurations for 7360 ISAM FX-8 in a 23 in. rack................................................................................................... 3-7 Figure 3-4 Horizontal rack mounting configurations for 7360 ISAM FX-4 in an EIA standard 19 in. rack ........................................................................... 3-9 Figure 3-5 Horizontal rack mounting configurations for 7360 ISAM FX-4 in a 23 in. rack................................................................................................. 3-10
List of tables Table Table Table Table Table Table Table Table Table Table Table Table Table Table
x
1 7360 ISAM FX documentation set for ANSI......................................................... v 1-1 Features for 7360 ISAM FX R4.3.01 .............................................................. 1-6 1-2 Features for 7360 ISAM FX R4.3.02 .............................................................. 1-7 1-3 Features for 7360 ISAM FX R4.4................................................................... 1-7 1-4 Supported LT cards ................................................................................... 1-10 1-5 Mapped items in a 7360 ISAM FX system .................................................... 1-11 1-6 FANT-F in 7360 ISAM FX-16....................................................................... 1-12 1-7 FANT-F in 7360 ISAM FX-8......................................................................... 1-12 1-8 FANT-F in 7360 ISAM FX-4......................................................................... 1-13 1-9 Manager overview ..................................................................................... 1-16 1-10 NT card dimensioning .............................................................................. 1-17 1-11 Faceplate port applicability for SyncE ........................................................ 1-18 1-12 IWF capabilities....................................................................................... 1-18 1-13 Ethernet frame size for LT cards ............................................................... 1-20
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
Contents
Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table
1-14 LT card dimensioning information ............................................................. 1-21 1-15 GPON-specific dimensioning information ................................................... 1-22 1-16 Total number of ports per LT card ............................................................ 1-23 1-17 NT Redundancy support-ready hardware modules ..................................... 1-24 1-18 CLEI codes.............................................................................................. 1-24 2-1 7360 ISAM FX shelves supported.................................................................. 2-2 2-2 Shelf configurations..................................................................................... 2-5 2-3 Mounting options/kits for 7360 ISAM FX shelves ............................................ 2-7 2-4 Supported plug-in units in 7360 ISAM FX shelves........................................... 2-8 3-1 7360 ISAM FX supported rack equipment...................................................... 3-2 3-2 Rack mounting configurations for 7360 ISAM FX-16....................................... 3-3 3-3 Horizontal rack mounting configurations for 7360 ISAM FX-8.......................... 3-5 3-4 Horizontal rack mounting configurations for 7360 ISAM FX-4.......................... 3-8 4-1 Characteristics of approved optical modules .................................................. 4-2 5-1 Number of shelves per rack ......................................................................... 5-4 5-2 Ordering plug-in units and cables for the 7360 ISAM FX shelves ..................... 5-4 5-3 Number of LT ports per LT card ................................................................... 5-5 5-4 Number of NT ports per NT card .................................................................. 5-5 6-1 7360 ISAM FX equipment............................................................................. 6-2 6-2 Rack mounting configurations ...................................................................... 6-3 6-3 Racks ......................................................................................................... 6-3 6-4 FEMA level rack mounting parts for 7360 ISAM FX-16 .................................... 6-3 6-5 Rack mounting parts for 7360 ISAM FX-8 and 7360 ISAM FX-4 ...................... 6-4 6-6 Orderable 7360 ISAM FX shelves .................................................................. 6-6 6-7 Orderable GFCs........................................................................................... 6-7 6-8 Orderable fan units and filters ...................................................................... 6-8 6-9 Orderable NT card and NT dummy front panel .............................................. 6-9 6-10 Orderable NTIO dummy front panel .......................................................... 6-10 6-11 Orderable LT cards and LT dummy front panels......................................... 6-10 6-12 Orderable optical modules........................................................................ 6-11 6-13 Orderable CO external alarm cables .......................................................... 6-13 A-1 Equipment mnemonics ................................................................................A-2
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
xi
Contents
xii
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
System and equipment overview 1 — System overview 2 — Shelves 3 — Rack mounting configurations 4 — Optical modules
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
1 — System overview
1.1 Introduction
1-2
1.2 Feature descriptions
1-6
1.3 System architecture
1-7
1.4 Network management 1.5 Equipment management
1-14 1-16
1.6 Card capabilities and dimensioning 1.7 NT redundancy support 1.8 CLEI codes
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
1-17
1-23
1-24
1-1
1 — System overview
1.1
Introduction This chapter provides general information about the 7360 ISAM FX system including network topology, feature descriptions, system architecture, network management, equipment management, card capabilities, NT redundancy support, and CLEI code information.
Network topology The 7360 ISAM FX system is a frame-based multi-service access platform, offering high-density fiber connections for multimedia, high-speed Internet access, voice, and business services. Figure 1-1 shows the basic 7360 ISAM FX network topology.
1-2
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
1 — System overview Figure 1-1 Basic 7360 ISAM FX network topology IP edge router/ BRAS NSP IP backbone
Ethernet Switch FE/GE/ 10GE
Ethernet DS1/E1
ISAM
NSP IP backbone
EMAN
Video FE/GE/ 10GE NSP IP backbone
ISAM ISAM shelf Ethernet
FE/GE/10GE
Eth LT
FE/GE/10GE
DS1/E1 Video Ethernet ONT
ONT
OMCI GPON
GPON LT
NT
EPON LT
OAM EPON
ISAM OLT
22417
Note 1 — Possible user interface types are not limited to the types
shown in the Figure 1-1. Note 2 — A link is a term that refers to the physical layer of an
interface of the 7360 ISAM FX, for example, an Ethernet link.
Subscriber side At the subscriber side, each 7360 ISAM FX shelf can terminate:
• Ethernet user interfaces • PON interfaces
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
1-3
1 — System overview
You can connect subtending DSLAMs to the FE/GE/10GE links at the subscriber side in:
• cascading topology mode: a chain of one subtending ISAM per ISAM; see Figure 1-2
• star topology mode: multiple subtending ISAMs per ISAM; see Figure 1-3 • ring topology mode: (except when there is a ring behind a Hub-ISAM); see Figure 1-4 Figure 1-2 Cascading topology mode Cascading up to three levels k*FE/GE/10GE
k*FE/GE/10GE
ISAM ISAM User interfaces
ISAM EMAN
User interfaces
User interfaces 22420
Figure 1-3 Star topology mode
k*FE/GE/10GE
ISAM
ISAM EMAN
User interfaces
User interfaces
ISAM
k*FE/GE/10GE
User interfaces 22421
1-4
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
1 — System overview Figure 1-4 Ring topology mode
k*FE/GE/10GE
ISAM
User interfaces k*FE/GE/10GE
ISAM
ISAM EMAN User interfaces
User interfaces
ISAM k*FE/GE/10GE User interfaces 22422
Network side At the network side, the 7360 ISAM FX terminates FE, GE, or 10GE links. Following are possible configurations.
• Connect to one or more Ethernet switches. Ethernet links can be connected to one or more Ethernet switches. These Ethernet switches forward the frames over the Ethernet-based aggregation access network until they reach the IP edge router or BRAS of the corresponding NSP. At the IP edge router or BRAS, the frames enter the IP backbone of the NSP. • Connect more than one FE/GE/10GE link (link aggregation). In case of more than one link, Ethernet link aggregation is used. • Connect directly to an IP edge router. The 7360 ISAM FX can be connected directly to the IP edge router or BRAS. The Ethernet aggregation network is reduced to one or more parallel Ethernet links. • Connect to a MPLS network. Figure 1-5 shows the 7360 ISAM FX system network connections.
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
1-5
1 — System overview Figure 1-5 Network connections IP edge router/ BRAS NSP IP backbone
Ethernet Switch User interfaces
m x FE/GE/10GE
NSP IP backbone
EMAN
ISAM FE/GE m x FE/GE/10GE
NSP IP backbone User interfaces NSP IP backbone
ISAM FE/GE
22423
1.2
Feature descriptions This section provides a brief description of the features for the 7360 ISAM FX system.
Release 4.3.01 features Table 1-1 describes the features for 7360 ISAM FX R4.3.01. Table 1-1 Features for 7360 ISAM FX R4.3.01 Feature ANSI hardware support
Description Following is a list of ANSI-supported hardware for release 4.3.01:
• • • • • • • • • • • •
NFXS-D, 16-slot shelf NFXS-E, 8-slot shelf NFXS-F, 4-slot shelf FANT-F, BC variant NT card with a 480 Gbps switch NELT-B, GPON LT card version B NGLT-A, GPON LT card version A PDBP-C, GFC for the 16-slot shelf (preinstalled) NGFC-H, GFC for the 8-slot shelf NGFC-G, GFC for the 4-slot shelf AFAN-H, fan unit for 16-slot shelf AFAN-E, fan unit for 8-slot shelf AFAN-X, fan unit for 4-slot shelf
Table 1-2 describes the features for 7360 ISAM FX R4.3.02.
1-6
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
1 — System overview Table 1-2 Features for 7360 ISAM FX R4.3.02 Feature
Description
ANSI hardware support
FANT-F, BD variant NT card with a 480 Gbps switch
Table 1-3 describes the features for 7360 ISAM FX R4.4. Table 1-3 Features for 7360 ISAM FX R4.4 Feature
Description
ANSI hardware suppport
FGLT-A, 16 port GPON LT card NGLT-C, 8 port GPON LT card XG-PON1 OLT XFP N1 Ctemp XG-PON1 ONU SFP+ N2A Itemp
1.3
System architecture This section describes the 7360 ISAM FX system architecture including the functional and physical components, and IHub.
Functional components The 7360 ISAM FX is a multiplexer, which can be equipped with the following main cards:
• • • •
NT card (optionally 1+1 redundant) NTIO card (optional) (not currently supported) LT cards implementing the user interfaces GPON LT cards Note — The XG-PON1 LT card is not supported in the current release. Related information is provided in the customer documentation in anticipation of their subsequent availability.
Figure 1-6 shows the 7360 ISAM FX functional components.
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
1-7
1 — System overview Figure 1-6 7360 ISAM FX functional components
ISAM
NT
LT
NTIO
...
LT-applique 22424
The 7360 ISAM FX management plane, control plane, and most of the data plane are provided on the NT cards and on the LT cards. Figure 1-7 shows the 7360 ISAM FX system components. Figure 1-7 7360 ISAM FX system components LT
NT iHub
LT-Control
iHub control
Transport
IWF
Switch/Router
System control Data plane Control plane 22425
NT cards
The 7360 ISAM FX NT cards consist of an IHub subsystem and a system control subsystem.
• The IHub subsystem has enhanced L2 functionality (VPLS based) and L3 functionality (VPRN based) and consists of a 10 GE switch/router device, and IHub control SW. • The system control subsystem implements the management plane of the system (both the NT cards and the LT cards) and part of the control plane (subscriber management in particular). The system control consists of SW running on a general purpose processor, shared with the IHub control SW (on a separate processor core).
1-8
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
1 — System overview
LT cards
The 7360 ISAM FX LT cards provide an IWF, a transport subsystem, and an LT control subsystem.
• The transport subsystem terminates the physical layer of the user interfaces. The transport subsystem varies with the type of access technology used, such as Ethernet. • The IWF processes the packets in the fast path. The IWF is capable of handling frames at L2 (basically bridging) and L3 (basically IP forwarding), including sophisticated filtering and traffic management, all at the line rate of the transport medium. • The LT control subsystem provides the slow path control plane and internal operations and maintenance applications. GPON LT cards
The GPON functionality of the 7360 ISAM FX extends the system boundaries up to 128 ONTs over fiber that can reach tens of kilometers from the GPON LT cards located in a 7360 ISAM FX shelf. These GPON LT cards provide the physical interfaces from the 7360 ISAM FX shelf toward the CPE, or the ONTs. XG-PON1 LT cards
The XG-PON1 functionality of the 7360 ISAM FX provides higher speed data rates of 10G downstream and 2.5G updstream.
Physical components Figure 1-8 shows the forwarding architecture of the 7360 ISAM FX system. Figure 1-8 7360 ISAM FX forwarding architecture Network links Subtending links User links
NT
LT IHUB router
EMAN EPS
IHUB control
2-n
IWF
Transport LT control
Ethernet GPON EPON
CPE ONT ONT
NTIO System control
22426
A 7360 ISAM FX shelf consists of the following card types:
• NT cards • LT cards
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
1-9
1 — System overview
• NTIO card (not currently supported) • GFC card NT cards
The shelf can accommodate two NT cards. These NT cards can act as an active/standby pair for all functions. The FANT-F (480 Gbps) NT card is supported in 7360 ISAM FX equipment. This NT card with integrated IHub subsystem provides the following links on the front panel:
• 1 x fixed 10/100/1000Base-T port. • • • • •
This port operates in 10 Mb/s, 100 Mb/s, or 1 GE mode. 4 x 10 GE SFP+ port: This port operates in 1 GE mode (with standard SFP optics) and in 10 GE mode (with SFP+ optics). LCMI interface (RJ-45 connector) ToD/1PPS interface (RJ-45 connector) 10 MHz GPS interface (SMA connector) 1 PPS interface (SMA connector)
LT cards
The LT cards in the shelf consist of an IWF, the transport termination, and the LT control. The LT cards, also known as LIMs, use a different IWF between the user side and the Ethernet network side, depending on the card type. Table 1-4 lists the supported LT cards with their physical interface types, density (that is, number of lines per card), and IWF capability. Table 1-4 Supported LT cards LT card
Physical interfaces
Overlay
Density
NT interface
IWF
NELT-B
Ethernet
—
36
10 GE
L3
(1)
FGLT-A
GPON
—
16
40 GE
L3
(1) (2)
NGLT-A
GPON
—
8
10 GE
L3
(1) (2)
NGLT-C
GPON
—
8
20 GE
L3
(1) (2)
Notes (1) L3: IWF capability on Layer 2 and Layer 3. For an overview of the IWF capabilities, see section 1.6. (2) Not all L3 features are supported in these ports, see Table 1-12.
1-10
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
1 — System overview
GFC card
The GFC provides connections for external power, circuit breakers for system protection, visual indications for power availability, and collection and cascading of external alarms. Note — These cards are only used on the 7360 ISAM FX-8 and the 7360 ISAM FX-4.
NTIO card
The 7360 ISAM FX NTIO card plays the role of an applique to a single NT card, or to both NT cards, dependant on the NT redundancy configuration. The NTIO card can decouple NT equipment protection from up-link protection in case of a redundant NT pair. If the active NT fails, traffic on the NTIO external links will be switched automatically to and from the standby NT. Port mapping
The following tables list the port mapping for the 7360 ISAM FX system, that is, the mapping between the logical port numbers as used in the system and the physical port numbers as visible on the equipment (front panel numbering).
• Table 1-5 lists the mapped items in a 7360 ISAM FX system. • Table 1-6 lists the port mapping for the FANT-F card in a 7360 ISAM FX-16 shelf. • Table 1-7 lists the port mapping for the FANT-F card in a 7360 ISAM FX-8 shelf. • Table 1-8 lists the port mapping for the FANT-F card in a 7360 ISAM FX-4 shelf. Table 1-5 Mapped items in a 7360 ISAM FX system Item
Description
Physical port number
Physical switch device port number
Logical port number
Port number as denoted in the SNMP management interface
LT port number
For internal LT ports, the index of the LT in the main shelf that corresponds to this port (for local LTs only)
(index based) Front panel port number
For external ports, how this port is identified at the front panel of the card
Port state / configurability
For NTIO ports, how this port can be configured:
• • • •
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
UP for uplinks/subtending/user links DOWN for internal LT links FIXED for fixed configuration (UP or DOWN) CONF for configurable configuration (UP or DOWN)
1-11
1 — System overview Table 1-6 FANT-F in 7360 ISAM FX-16 Physical port number
Logical port number
LT slot number (index based)
Faceplate port number
Interface
10
15
1
—
—
12
16
2
—
—
16
17
3
—
—
18
18
4
—
—
32
19
5
—
—
34
20
6
—
—
41
21
7
—
—
43
22
8
—
—
45
23
9
—
—
37
24
10
—
—
22
25
11
—
—
8
26
12
—
—
39
27
13
—
—
28
28
14
—
—
20
29
15
—
—
17
30
16
—
—
2
5
—
1 (NT-A)
RJ-45
4
6
—
X1 (NT-A)
SFP+
5
7
—
X2 (NT-A)
SFP+
6
8
—
X3 (NT-A)
SFP+
7
9
—
X4 (NT-A)
SFP+
3
3
—
IEEE1588 (NT-A)
—
—
10
—
1 (NT-B)
RJ-45
—
11
—
X1 (NT-B)
SFP+
—
12
—
X2 (NT-B)
SFP+
—
13
—
X3 (NT-B)
SFP+
—
14
—
X4 (NT-B)
SFP+
—
4
—
IEEE1588 (NT-B)
—
Table 1-7 FANT-F in 7360 ISAM FX-8 Physical port number
Logical port number
LT slot number (index based)
Faceplate port number
Interface
10
15
1
—
—
12
16
2
—
—
(1 of 2)
1-12
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
1 — System overview
Physical port number
Logical port number
LT slot number (index based)
Faceplate port number
Interface
16
17
3
—
—
18
18
4
—
—
32
19
5
—
—
34
20
6
—
—
41
21
7
—
—
43
22
8
—
—
2
5
—
1 (NT-A)
RJ-45
4
6
—
X1 (NT-A)
SFP+
5
7
—
X2 (NT-A)
SFP+
6
8
—
X3 (NT-A)
SFP+
7
9
—
X4 (NT-A)
SFP+
3
3
—
IEEE1588 (NT-A)
—
—
10
—
1 (NT-B)
RJ-45
—
11
—
X1 (NT-B)
SFP+
—
12
—
X2 (NT-B)
SFP+
—
13
—
X3 (NT-B)
SFP+
—
14
—
X4 (NT-B)
SFP+
—
4
—
IEEE1588 (NT-B)
—
(2 of 2)
Table 1-8 FANT-F in 7360 ISAM FX-4 Physical port number
Logical port number
LT slot number (index based)
Faceplate port number
Interface
10
15
1
—
—
12
16
2
—
—
16
17
3
—
—
18
18
4
—
—
2
5
—
1 (NT-A)
RJ-45
4
6
—
X1 (NT-A)
SFP+
5
7
—
X2 (NT-A)
SFP+
6
8
—
X3 (NT-A)
SFP+
7
9
—
X4 (NT-A)
SFP+
3
3
—
IEEE1588 (NT-A)
—
—
10
—
1 (NT-B)
RJ-45
—
11
—
X1 (NT-B)
SFP+
—
12
—
X2 (NT-B)
SFP+
(1 of 2)
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
1-13
1 — System overview
Physical port number
Logical port number
LT slot number (index based)
Faceplate port number
Interface
—
13
—
X3 (NT-B)
SFP+
—
14
—
X4 (NT-B)
SFP+
—
4
—
IEEE1588 (NT-B)
—
(2 of 2)
IHub The IHub provides L2 bridging (based on VPLS) and IP routing (based on VPRN). The IHub has at least 28 ports with various specializations. A number of ports are used to make a connection at 1 Gb/s or at 2.5 Gb/s or at 10 Gb/s to an LT local in the shelf (one IHub link per LT). The connection speed depends on the LT capabilities; see Table 1-4. The FE/GE ports, which are not used for connecting LT cards (local or remote), and the 10GE ports, are available as network interfaces, interfaces to subtended DSLAM systems, or for connecting directly to users. These links serve network links, subtending links, or user links respectively. Use of these ports is possible through:
• link interfaces that are physically located on an NTIO card, connected via bidirectional P2P high-speed connections on the backplane to both NT cards These interfaces can also be used as electrical FE or GE interfaces, or optical GE, or 10GE interfaces, for uplink, subtending, or user links. The NTIO card contains an NT equipment protection switch per external link interface. Link protection and NT equipment protection can be performed independently from each other for links terminated on the NTIO. • link interfaces that are physically located on the NT card, as electrical FE or GE interfaces, or optical GE or 10 GE interfaces, for uplink, subtending, or user links.
1.4
Network management This section provides network management information for the 7360 ISAM FX system. Figure 1-9 shows how the 7360 ISAM FX system can be managed in a network.
1-14
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
1 — System overview Figure 1-9 7360 ISAM FX network management
ISAM EMS
Remote CT CLI (via Telnet) TL1 (via UDP-login)
CT
RS232
IACM
EMAN
LIM
LIM
xHub
LIM
Network Ports
Management Flow to cascaded ISAM 20768
The remote craft terminal (CT) uses TL1 commands or command line interface (CLI) commands. TL1 is used for pre-provisioning of the NT cards. CLI is used to manage both the xHub subsystem and the IACM. Figure 1-10 shows the management topology for the 7360 ISAM FX. Figure 1-10 7360 ISAM FX management topology
EMS TL1 Gateway TL1 Terminal (e.g. AMS 5520) SNMPv2 or SNMPv3
UDP
SNMP agent
ISAM
SSH
TL1 agent
TL1 CT RS232
CLI Terminal SSH
Telnet
CLI CT RS232
CLI agent
Debug Terminal UDP
Debug agent
20767
The NT controller and the xHub subsystem each contain a separate SNMP agent. These can be managed using an element management station (EMS), such as the Alcatel-Lucent 5520 AMS. It is also possible to use a local TL1 or CLI craft terminal on the NT card to manage the LT cards. An integrated CLI approach is implemented on the NT card using a CLI agent. This agent implements CLI commands for the NT controller / LIMs and the xHub subsystem. However, there is no semantic integration. Table 1-9 shows an overview of the involved managers.
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
1-15
1 — System overview Table 1-9 Manager overview Type
Description
EMS
Element management system (EMS) based on SNMP. The Alcatel-Lucent work station (5520 AMS) is commonly used.
CT
Craft terminal using TL1 commands or command line interface (CLI) commands.
Note 1 — External OAM VLAN:
The IHub subsystem supports in-band management. This happens through a dedicated VLAN, which must be configured (if different than 4093) on both the IHub subsystem as on the NT. Note 2 — VLAN 4094 is reserved for internal communication and cannot be used in any Ethernet network in which the 7360 ISAM FX system is deployed.
1.5
Equipment management This section describes the 7360 ISAM FX general equipment practice including CO equipment management, SyncE support, IWF capabilities, Ethernet frame size, dimensioning information, and OLT service and system capacity. The NE equipment practice type does not have to be explicitly planned by the operator, but is auto-planned by the NT at startup, depending on the detected type. At the same time, the NT will auto-plan the maximum number of racks supported by this equipment practice. The following 7360 ISAM FX type is defined:
• LNWW: large new equipment practice worldwide market (6 racks, 4 shelves per rack) Shelves are automatically planned upon detection. The operator can control the administrative state of a shelf (lock/unlock). The NE manages different types of cards. A complete overview of all supported card types in each type of shelf is in the chapter 2 “Shelves”. Card planning is supported for all types of cards, including the appliques. For LSMs, the operator can control the administrative state (lock/unlock).
CO equipment management CO equipment only supports configurations consisting of a single rack and shelf.
ONT management For more information about the ONT management, see System Description for FD 100/320Gbps NT and FX NT.
1-16
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
1 — System overview
1.6
Card capabilities and dimensioning This section provides an overview of:
• • • • • •
dimensioning information for the NT cards; see Table 1-10 SyncE support on NT cards and NTIO cards; see Table 1-11 the IWF capabilities of the LT cards per forwarding type; see Table 1-12 Ethernet frame size; see Table 1-13 dimensioning information of the LT cards per forwarding type; see Table 1-14 GPON-specific dimensioning; see Table 1-15
NT card dimensioning Table 1-10 lists the dimensioning for the NT cards and their variants. Table 1-10 NT card dimensioning Description
FANT-F
Throughput
480 Gbps
Maximum number of MAC addresses
(FDB)(1)
128 k
Maximum number of IP interfaces ARP table size
Maximum number of IP routes:
512 IPv4
16 k
IPv6
8k
IPv4 IPv6
FIB
16 k
RIB
16 k
FIB
8k
RIB
8k
Maximum number of L2 filters
512(2)
Maximum number of L3 filters
512
Maximum number of VLANs
4k
Maximum number of cross-connects
4k
Maximum number of ONTs
16
Maximum number of UNIs
19584
Maximum number of VLAN ports
103680
Maximum number of CC VLAN
49152
Maximum number of (active) MC streams
2k
Maximum number of L2-terminated VLAN
3072
L2 frame size (in bytes)
2048
External interfaces
1 x El. GE 4 x 1/10 GE
BITS in/out ports
1/1
SyncE input/output
4/4
(1 of 2)
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
1-17
1 — System overview
Description
FANT-F
IEEE1588 slave for frequency synchronization
Y
(2 of 2) Notes (1) A number of MAC addresses are always used by the system for internal purposes. (2) The same resource is shared for L2 filters and L3 filters. So, the maximum cannot be obtained for both at the same time.
SyncE support Table 1-11 lists the port applicability of the SyncE NTR functionality for clock extraction (in) and generation (out). Table 1-11 Faceplate port applicability for SyncE Card
Port
SyncE in support
SyncE out support
FANT-F
X1
1 GE and 10 GE
1 GE and 10 GE
X2
1 GE and 10 GE
1 GE and 10 GE
X3
1 GE and 10 GE
1 GE and 10 GE
X4
1 GE and 10 GE
1 GE and 10 GE
IEEE 1588v2 PTP support The IEEE 1588v2 precise time protocol provides an upgraded architecture to improve syncronization accuracy and allow precise ToD information to be distributed within the NT and LT cards in a 7360 ISAM FX shelf. The ToD serial output and 1PPS signals are processed by the NT cards and are distributed to the LT cards through the backplane signals of the 7360 ISAM FX system to allow the collection of precise ToD information that can be measured on both the ToD/1PPS interface on the NT card, and on the system backplane.
IWF capabilities Table 1-12 lists the IWF capabilities of the LT cards. See Table 1-4 for an overview of the supported LT cards. Table 1-12 IWF capabilities Feature
L3
L3 GPON
NELT-B UNI
NNI
ATM AAL5 encapsulation type LLC/SNAP bridged (IPoE and PPPoE)
Y
—
—
—
LLC/SNAP routed (IPoA)
Y
—
—
—
LLC/NLPid (PPPoA)
Y
—
—
—
(1 of 3)
1-18
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
1 — System overview
Feature
L3
L3 GPON
NELT-B UNI
NNI
VC Mux bridged (IPoE and PPPoE)
Y
—
—
—
VC Mux routed (IPoA)
Y
—
—
—
VC Mux PPPoA (PPPoA)
Y
—
—
—
Auto-detect IP (between LLC/SNAP bridged and routed)
Y
—
—
—
Auto-detect PPP (between LLC/SNAP bridged, VC Mux bridged and LLC-NLPID, VC Mux PPPoA)
Y
—
—
—
Auto-detect IP+PPP
Y
—
—
—
Auto-detect PPPoA (between LLC-NLPID and VC Mux PPPoA)
Y
—
—
—
Reception of untagged packets
Y
—
Y
Y
Reception of combination of untagged and priority-tagged packets
Y
—
Y
Y
Reception of single-tagged packets
Y
Y
Y
Y
Reception of combination of untagged, priority-tagged, single-tagged packets
Y
Y
Y
Y
Port-based default VLAN for untagged/priority-tagged (if applicable) packets
Y
Y
Y
Y
Port- and protocol-based default VLAN for untagged/priority-tagged packets of the IpoE protocols
Y
Y
Y
Y
Port- and protocol-based default VLAN for untagged/priority-tagged packets of the PPPoE protocols
Y
Y
Y
Y
Priority-bit re-marking and mapping table for tagged/priority-tagged packets
Y
Y
Y
Y
RB mode: protocol filter (set of Ethertypes) for upstream traffic in VLANs in (PPPoE and IpoE)
Y
Y
Y
Y
RB mode Ethernet packet types: Ethernet II encap on Ethernet
Y
Y
Y
Y
RB mode Ethernet packet types: LLC/SNAP on Ethernet
Y
Y
Y
Y
CC mode: transparently pass all encapsulations (for example, PPPoE and IpoE)
Y
Y
Y
Y
CC mode: protocol filter
Y
Y
—
Y
CC mode: IPoA to IPoE CC
Y
—
—
—
VLAN stacking (S-VLAN CC and S-VLAN/C-VLAN CC)
Y
Y
Y
Y
VLAN stacking (S-VLAN/C-VLAN residential bridge)
—
—
—
—
QoS-aware CC
Y
—
—
—
ARP: enabling/disabling broadcast
Y
Y
Y
—
802.1X authentication
Y
Y
Y
—
Encapsulation autodetect
Bridged encapsulation Ethernet packet formats
Packet processing
L2 Forwarding
L2 Forwarding user access protocols
(2 of 3)
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
1-19
1 — System overview
Feature
L3
L3 GPON
NELT-B UNI
NNI
DHCP option 82 insertion
Y
Y
Y
—
PPPoE relay tag
Y
Y
Y
—
PPPoA-PPPoE relay
Y
—
—
—
Multicast services access control
Y
Y
Y
—
Multicast services resource control
Y
Y
Y
Y
L3 Forwarding IPoE
(1)
Y
Y
Y
—
IPoA
(1)
Y
Y
Y
—
Y
Y
Y
—
802.1X authentication
Y
—
Y
—
ARP proxy user side for IPoE
Y
Y
—
—
DHCP relay
Y
—
Y
—
CAC profile
Y
Y
Y
Y
Association of QoS profiles to ports
Y
Y
Y
Y
Association of QoS profiles to port-VLAN associations
Y
Y
Y
Y
Sub-flow counters
—
Y
—
—
VLAN termination (at network side), forwarding at Layer 3 L3 Forwarding user access protocols
QoS
(2)
(3 of 3) Notes (1) IP aware bridge is only supported on L3 LT cards with 1GE NT interface; not on L3 LT cards with 2.5GE NT interface GPON LT cards and NELT-B (2) Support policing on bridge port on L2.
Ethernet frame size Table 1-13 lists the supported Ethernet frame size for the LT cards. Table 1-13 Ethernet frame size for LT cards
1-20
LT card
Encapsulation
Frame size (bytes)
P2P Ethernet
NELT-B UNI (with FCS)
1976
NELT-B NNI (with FCS)
2048
OLT
FGLT-A (with FCS)
2000
OLT
NGLT-A (with FCS)
2000
OLT
NGLT-C (with FCS)
2000
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
1 — System overview
Dimensioning of the LT cards Table 1-14 lists the dimensioning information for the LT cards. See Table 1-4 for an overview of the supported LT cards. Table 1-14 LT card dimensioning information Feature
L3
L3 GPON
NELT-B UNI
NNI
—
—
General Maximum number of PONs
(2)
—
8 16
Maximum number of UNIs
—
4096
—
—
Maximum number of FE ports per card
—
—
36
36
Maximum number of GE ports per card
—
—
36
36
Maximum number of UNI port type (FE) per card
—
—
36
—
Maximum number of UNI port type (GE) per card
—
—
36
—
Maximum number of NNI port type (FE) per card
—
—
—
36
Maximum number of NNI port type (GE) per card
—
—
—
36
Maximum number of CC VLAN
768
11 520
4608
4608
Maximum number of RB VLAN
768
1296
1296
1296
Maximum number of VLAN per PVC
16
8
—
—
Maximum number of port-VLAN associations per LT
384
11 520
144
4608
Maximum number of VLAN port per UNI (FE/GE)
—
—
8
—
Maximum number of VLAN port per NNI (FE/GE)
—
—
—
256
Maximum number of MAC addresses per VLAN port
64
64
—
—
Maximum number of MAC addresses per UNI
—
—
64
—
Maximum number of MAC addresses per NNI
—
—
—
3072
Maximum number of MAC addresses per LT (including static)
1024
16 K(1)
2304
32768
Maximum number of user IP addresses per LT (including static)
384
8K
—
—
Average number of IPv4 subnets or addresses per card (=Average IP anti-spoofing entries, full/32 IP address or subnet, per card
—
—
288
0
Maximum number of IPv4 hosts per card
—
—
288
0
(1 of 2)
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
1-21
1 — System overview
Feature
L3
L3 GPON
NELT-B UNI
NNI
Maximum number of IPv6 subnets or addresses per UNI
—
—
16
0
Maximum number of IPv6 subnets or addresses per VLAN port
—
—
4
0
Maximum number IPv6 host addresses per card
—
—
288
0
Maximum number of VRFs per LT
128
N\A
—
—
Maximum number of simultaneous multicast channels per LT
1024
1024
1024
1024
Maximum number of multicast groups per user
100
100
100
1024
Maximum number of multicast VLANs
128
64
—
—
Maximum number of 802.1x sessions per PON
—
288
—
—
Maximum number of 802.1x sessions per UNI
—
—
1
—
Maximum number of 802.1x sessions per card
—
2304
36
—
Multicast dimensioning
802.1x
(2 of 2) Notes (1) A few MAC addresses are used by the system for internal purposes. (2) Dependant on variant of LT card; NGLT-A/NGLT-C:8, FGLT-A:16.
ISAM OLT service and system capacity This section provides information about the 7360 ISAM FX service and system capacities, and ISAM OLT performance, distance, and connection capacities. Service and system capacities
Table 1-15 lists dimensioning information specific to the GPON functionality. Table 1-15 GPON-specific dimensioning information
1-22
Feature
L3 GPON
Maximum number of ONT per PON
128
Maximum number of UNIs per PON
288
Maximum number of TCONTs per PON
1024
Maximum number of GEM ports per PON
2048
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
1 — System overview
ISAM OLT performance and distance
The P-OLT provides performance and distance capacity of 2.488 Gb/s downstream and 1.244 Gb/s upstream, within a 30 km (18.6 mi) span, for all NGLT cards. The optical link budget is defined by both loss and bandwidth characteristics. The loss characteristic is determined by the difference between the optical transmitter and optical receiver for each direction, and is typically 28 dB. The bandwidth characteristic is determined by the maximum link distance parameter of each OLT and ONT transmitter specification, and is limited by the smaller of the upstream and downstream values. ISAM OLT connection capacities
The ISAM OLT can accommodate a maximum of 16 LT cards. The number of ports depends on the LT card used. Table 1-16 describes the total number of ports per LT card. Table 1-16 Total number of ports per LT card
1.7
Card type
Number of ports per card
Totalnumber of ports
FGLT-A
16
256
NGLT-A
8
128
NGLT-C
8
128
NT redundancy support Four levels of redundancy are supported:
• • • •
link redundancy equipment redundancy subscriber line redundancy application redundancy
NT redundancy implements link redundancy and equipment redundancy in a decoupled architecture, which results in the following redundancy cases:
• only link protection: • • • •
single NT, active-standby, or load-sharing uplinks combined NT and link protection, no NTIO: dual active/standby NT, with direct uplink or link set decoupled NT and link protection, single NTIO: dual active/standby NT, NTIO card with link switches NT protection, passive link protection, no NTIO: single, active-standby or load sharing uplinks subtending system protection
Table 1-17 lists the hardware modules that are ready for NT redundancy support. Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
1-23
1 — System overview Table 1-17 NT Redundancy support-ready hardware modules Type
Module
Shelf
NFXS-D NFXS-E NFXS-F
NT cards
FANT-F
LT cards
NELT-B NGLT-A NGLT-C FGLT-A
1.8
CLEI codes This sections provides the currently available CLEI codes. Table 1-18 lists the cards and fan units for which CLEI codes are available. Caution — The CLEI code changes whenever an item change (that is, an adaptation to a card) occurs.
The latest status of these CLEI codes is always available on the following website: https://codecenter.commonlanguage.com/applogin.asp?app=clei_inq uiry An account is required before the CLEI database can be accessed. Table 1-18 CLEI codes Mnemonic
Variant
CLEI code
CPR
Bar code
AFAN-E
3FE 65060 AA
VAUCAJ86AA
072AXJ
178692
AFAN-H
3EC 37533 NB
VAUCAE2KAA
070LXX
154967
AFAN-X
3FE 64994 AA
VAUCAJ56AA
072ARC
178361
FANT-F
3FE 53701 BD
VAI2AHVNAA
072DJP
182107
FGLT-A
3FE 66721 AA
—
—
—
NELT-B
3FE 62543 AA
VAUCAJ36AA
072AEY
177909
NFXS-D
3FE 65209 BA
VAMZ600BRA
215138
463997
NFXS-E
3FE 64936 BA
VAMZ400BRA
215136
463993
NFXS-F
3FE 64991 BA
VAMZ500BRA
215137
463996
NGFC-G
3FE 65676 AA
VAUCAK26AA
—
—
NGFC-H
3FE 65675 AA
VAUCAK36AA
—
—
(1 of 2)
1-24
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
1 — System overview
Mnemonic
Variant
CLEI code
CPR
Bar code
NGLT-A
3FE 64279 AA
VAI2AFHDAA
070YVT
175498
NGLT-C
3FE 67301 AA
—
—
—
(2 of 2)
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
1-25
1 — System overview
1-26
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
2 — Shelves
2.1 Overview
2-2
2.2 7360 ISAM FX shelves 2.3 Supported plug-in units 2.4 Dummy front panels
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
2-2 2-7 2-8
2-1
2 — Shelves
2.1
Overview This chapter provides information about the different 7360 ISAM FX shelves supported for ANSI.
2.2
7360 ISAM FX shelves This section provides general information about the 7360 ISAM FX shelf types, shelf configurations, NT redundancy, fan unit, baffles, and drip tray. The modular organization of the 7360 ISAM FX system allows a wide range of physical size and traffic capacity options. The basic building blocks of the 7360 ISAM FX system are the shelves. The 7360 ISAM FX system for R4.x is a one-shelf system. Daisy-chaining multiple shelves using extender cards is not supported. Multiple collocated shelves can be cascaded using the standard FE, GE, and 10 GE subtending links. In such a configuration, each shelf operates and is managed as a separate system.
Shelf types Table 2-1 lists the 7360 ISAM FX shelves supported. Table 2-1 7360 ISAM FX shelves supported Item
Shelves 7360 ISAM FX16
7360 ISAM FX8
7360 ISAM FX4
Code
3FE 65209 BA
3FE64936 BA
3FE-64991 BA
Mnemonic
NFXS-D
NFXS-E
NFXS-F
Dimensions
Width Height Depth
Can be mounted in:
529 mm
482.5 mm
482.5 mm
20.83 in.
19.00 in.
19.00 in.
622.5 mm
355 mm
222 mm
24.51 in.
13.98 in.
8.74 in.
max. 280 mm
278.3 mm
278.3 mm
11.02 in.
10.96 in.
10.96 in.
19 in. EIA standard racks
N
Y(1)
Y(1)
23 in. racks
Y(1)
Y(1)
Y(1)
Note (1)
Specific mounting kits must be used. See Table 2-3 for mounting kit requirements.
Figure 2-1 shows the 7360 ISAM FX-16 shelf. 2-2
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
2 — Shelves
Figure 2-2 shows the 7360 ISAM FX-8 shelf. Figure 2-3 shows the 7360 ISAM FX-4 shelf. Figure 2-1 7360 ISAM FX-16 shelf
Card cage area
02
03
04
05
BO N
D
I N G
07
08
NTA
Energy Hazard
A/70 FOR LT
NTIO
NTB
09
11
12
7360 ISAM FX-16
B/70 FOR LT
-48V 70A
10
ON
A R T H
OFF
ON
E
ESD
06
OFF
N594
I N T
01
General function and control unit
14
15
BAT A
MAJOR
BAT B
MINOR
ACO
16
PO
Fan unit
ALM
Power unit and cable connection area
13
CRITICAL
Energy Hazard
BITS INTERFACE NT-A NT-B
TIME OF DAY
1 Hz-PULSE RING TIP FRAME GND
CRAFT PORT
TB
1-1
-4
T A BA 8V TB
1-2
TN TR BA
A TB
1-3
TN TR BA
B TB
1-4
-4
CO ALARMS
T B BA 8V
22120
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
2-3
2 — Shelves
04
05
06
07
08
Figure 2-2 7360 ISAM FX-8 shelf
NTB NTIO NTA N594
7360 ISAM FX-8
B-40A
Energy Hazard
Alarms
GND NTB
Remote Craft
BITS
External Alarms
FAN
Critical Major Minor
A-40A NTA
7360 ISAM FX-8
01
02
03
Card cage
BAT A BAT B
ACO
General facilities card
Fan unit 21957
02
03
04
Figure 2-3 7360 ISAM FX-4 shelf
NTIO NTA
7360 ISAM FX-4
NTB
01
Card cage
External Alarms
BITS
TOD/IHZ
Remote Craft
N594
7360 ISAM FX-4
NTA GND NTB
General facilities card
BAT A BAT B FUSE A B 1 2 3
Critical Alarms Major ACO Minor
FAN
Fan unit 22436
Shelf configurations Table 2-2 lists the shelf configurations.
2-4
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
2 — Shelves Table 2-2 Shelf configurations Configuration
7360 ISAM FX-16
7360 ISAM FX8
7360 ISAM FX4
Maximum number of LT cards
16
8
4
Maximum number of NT cards
2
2
2
Maximum number of NTIO cards
1 (optional)
1 (optional)
1 (optional)
The following figures show the general layout and the slot numbering for the 7360 ISAM FX shelves: Figure 2-4 shows the 7360 ISAM FX-16. Figure 2-5 shows the 7360 ISAM FX-8. Figure 2-6 shows the 7360 ISAM FX-4. Figure 2-4 Shelf configuration of 7360 ISAM FX-16
LT LT LT LT LT LT LT LT NT NTIO NT LT LT LT LT LT LT LT LT 1 2 3 4 5 6 7 8 A B 9 10 11 12 13 14 15 16
CBs, LEDs and switches Fan unit Connectors 22131
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
2-5
2 — Shelves Figure 2-5 Shelf configuration of 7360 ISAM FX-8 LT 8 LT 7 LT 6 LT 5 LT 4 LT 3 LT 2 LT 1 NT B
FAN
NT I/O NT A NGFC-H 21959
Figure 2-6 Shelf configuration of 7360 ISAM FX-4 LT 4 LT 3 LT 2 LT 1 NT B
FAN
NT I/O NT A NGFC-G 22406
NT redundancy The protection scheme for NT redundancy is 1+1 (active/active) in the data plane, and 1:1 (active/standby) in the control and management plane.
Fan unit One fan unit provides forced air cooling in the shelf. The fan unit is a field-replaceable unit in the shelf fan area and plugs directly into the backplane. The fan unit can be equipped with a fan filter.
Shelf mounting kits The mounting kits required for installation of 7360 ISAM FX-16 shelves are included with the shipment. The number of kits provided depends on the rack mounting configuration required, with either one or two shelves. Baffle kits, mounting bracket kits, and the required screws are all included. Specific mounting kits may be required for installation of the 7360 ISAM FX-8 and 7360 ISAM FX-4 shelves, depending on the rack mounting configuration.
2-6
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
2 — Shelves
Table 2-3 describes the mounting options and mounting kits available. See the 7360 ISAM FX Hardware Installation Manual for more information. Table 2-3 Mounting options/kits for 7360 ISAM FX shelves Type of rack / mount
7360 ISAM FX-4
7360 ISAM FX-8
19 in. EIA rack with horizontal mount
Shelf mounting kit optional
Shelf mounting kit optional
Includes:
Includes:
•
•
• 23 in. rack with horizontal mount
mounting brackets -not required mounting screws -required
•
mounting brackets -not required mounting screws -required
Shelf mounting kit required
Shelf mounting kit required
Includes:
Includes:
•
•
•
mounting brackets -required mounting screws -required
•
mounting brackets -required mounting screws -required
Heat and fiber management baffle A heat and fiber management baffle is installed with the 7360 ISAM FX-16 shelf for safety protection from heat, possible flame spread, and loose particles that may cause damage to equipment. Factory-installed fiber optic cabling ring-guides are used for proper fiber optic cable handling. See Figure 2-7. Figure 2-7 Heat and fiber management baffle for 7360 ISAM FX-16
22373
2.3
Supported plug-in units Table 2-4 lists the supported plug-in units in the 7360 ISAM FX shelves.
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
2-7
2 — Shelves Table 2-4 Supported plug-in units in 7360 ISAM FX shelves Slot
Plug-in Unit
Description
NTA
FANT-F
480 Gbps NT card
NTB
FANT-F
480 Gbps NT card
LT slot
NELT-B
36-line Ethernet (FE/GE) LT card
NGLT-A
GPON LT card with 8 GPON interfaces
NGLT-C
GPON LT card with 8 GPON interfaces
FGLT-A
GPON LT card with 16 GPON interfaces
NGFC-G
GFC for 7360 ISAM FX-8 shelf
NGFC-H
GFC for 7360 ISAM FX-4 shelf
AFAN-H NB
Fan unit for 7360 ISAM FX-16 shelf
AFAN-E
Fan unit for 7360 ISAM FX-8 shelf
AFAN-X
Fan unit for 7360 ISAM FX-4 shelf
General facilities card
Fan area
Note — For more information about the plug-in units, see the relevant UDS. The mnemonics that are used are explained in Appendix A.
2.4
Dummy front panels This section describes the 7360 ISAM FX shelf dummy panels (filler plates) for NT cards, optical LT cards, and NTIO cards. Dummy front panels must be mounted on any unused slot of a shelf to ensure:
• EMC compliance • thermal compliance via a correct airflow in the shelf • safety by avoiding direct contact with backplane connectors When a slot is provisioned, the dummy front panel is replaced by the appropriate card and the cables are connected to the card.
For NT cards A dummy front panel must be used when the second NT card is not installed. Figure 2-8 shows the dummy front panel for an NT card.
2-8
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
2 — Shelves
XX XX XX XXXXXXX
Figure 2-8 Dummy front panel for NT card
22197
For optical LT cards A dummy front panel must be used when an LT card is not installed (NGLT-A, NGLT-C, FGLT-A). Figure 2-9 shows the dummy front panel for optical LT cards.
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
2-9
2 — Shelves Figure 2-9 Dummy front panel for optical LT card
Dust cap
22198
For NTIO card A dummy front panel must be used when the NTIO card is not installed. Figure 2-10 shows the universal dummy front panel for an NTIO card.
2-10
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
2 — Shelves Figure 2-10 Universal dummy front panel for NTIO card
22429
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
2-11
2 — Shelves
2-12
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
3 — Rack mounting configurations
3.1 Overview
3-2
3.2 Rack equipment
3-2
3.3 7360 ISAM FX-16 rack mounting configurations
3-3
3.4 7360 ISAM FX-8 rack mounting configurations
3-5
3.5 7360 ISAM FX-4 rack mounting configurations
3-8
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
3-1
3 — Rack mounting configurations
3.1
Overview This chapter describes the rack equipment and the supported rack mounting configurations for the following 7360 ISAM FX shelves:
• 7360 ISAM FX-16 • 7360 ISAM FX-8 • 7360 ISAM FX-4 Note 1 — See chapter 6 for part numbers. Note 2 — See 7360 ISAM FX Hardware Installation Manual for
more information about how to install the equipment.
3.2
Rack equipment This section briefly describes the 7360 ISAM FX rack equipment and assembly. The rack equipment can be delivered as a pre-assembled rack or in separate kits. The rack assembly includes a rack, shelves, accompanying fan units, baffles, and drip tray assembly kits. Each rack configuration is ordered with a specific ordering code. The 7360 ISAM FX-16 rack mounting configurations include the rack, however, the racks are optional for the 7360 ISAM FX-8 and 7360 ISAM FX-4 rack mounting configurations. See Chapter 6 for ordering information. Parts can also be delivered separately or in kits, where the assembly is done on site at the customer location. Table 3-1 lists the 7360 ISAM FX system rack equipment that can be used, dependent on the rack configuration required and currently supported. Table 3-1 7360 ISAM FX supported rack equipment Size of rack
Shelf apeture between rack uprights
EIA standard 19 in. rack
17.75 in. (450.9 mm)
23 in. rack
21.5 in. (546.1 mm)
For more information about 7360 ISAM FX equipment and the supported racks and rack mounting configurations, see the 7360 ISAM FX Hardware Installation Manual.
3-2
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
3 — Rack mounting configurations
3.3
7360 ISAM FX-16 rack mounting configurations This section describes the 7360 ISAM FX-16 rack mounting configurations. The 7360 ISAM FX-16 can be installed vertically in a 23 in. rack. Table 3-2 lists the supported rack configurations for the 7360 ISAM FX-16 shelves in a 23 in. rack. An example of a configuration is shown in Figure 3-1. Table 3-2 Rack mounting configurations for 7360 ISAM FX-16 FEMA code
3FE 66742 AA
Rack unit
23 in. rack vertical mount
SR 1
NFXS-D
NFXS-D
Fiber and heat baffle kit
Fiber and heat baffle kit
Left and right mounting brackets
Left and right mounting brackets
Fan 1 SR 2
Fan 2
3FE 66742 AB
AFAN-H
AFAN-H
(with fan filter)
(with fan filter)
—
NFXS-D
—
Fiber and heat baffle kit
—
Left and right mounting brackets
—
AFAN-H (with fan filter)
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
3-3
3 — Rack mounting configurations Figure 3-1 Rack mounting configurations for 7360 ISAM FX-16 (3FE 66742 AB) 22.3 21.5
CRAFT PORT
BITS INTERFACE NT-A NT-B
TIME OF DAY
BITS INTERFACE NT-A NT-B
TIME OF DAY
1 Hz-PULSE RING TIP FRAME GND
CO ALARMS
34 RU
CRAFT PORT
1 Hz-PULSE RING TIP FRAME GND
CO ALARMS
22732
3-4
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
3 — Rack mounting configurations
3.4
7360 ISAM FX-8 rack mounting configurations This section describes the 7360 ISAM FX-8 rack mounting configurations. The 7360 ISAM FX-8 can be installed:
• horizontally in an EIA standard 19 in. rack • horizontally in a 23 in. rack Note — A 19 in. seismic rack with a 17.5 in. shelf aperture between the uprights is not supported.
Table 3-3 lists the supported horizontal rack mounting configurations for 7360 ISAM FX-8 shelves. Table 3-3 Horizontal rack mounting configurations for 7360 ISAM FX-8 Rack unit (1)
19 in. EIA rack horizontal mount
23 in. rack horizontal mount
SR 1
NFXS-E
NFXS-E
Shelf mounting kit
Shelf mounting kit
Fan 1 SR 2
AFAN-E
AFAN-E
(with fan filter)
(with fan filter)
—
NFXS-E Shelf mounting kit
Fan 2
—
AFAN-E (with fan filter)
Note (1)
Although only two rack units are portrayed in this table, up to five rack units are supported.
Figure 3-3 shows the 7360 ISAM FX-8 horizontal rack mounting configurations in am EIA standard 19 in. rack.
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
3-5
3 — Rack mounting configurations Figure 3-2 Horizontal rack mounting configurations for 7360 ISAM FX-8 in an EIA standard 19 in. rack 18.312 17.750
03
04
05
06
07
08
35 RU
NTB NTIO NTA
7360 ISAM FX-8
01
02
8 RU
7360 ISAM FX-8
B-40A
Energy Hazard
Energy Hazzard
Alarms
NTA
External Alarms
GND NTB BITS
FAN
Critical Major Minor
A-40A
TOD/IHZ
Remote Craft
BAT A BAT B
ACO
22736
Figure 3-3 shows the 7360 ISAM FX-8 horizontal rack mounting configurations in a 23 in. rack.
3-6
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
3 — Rack mounting configurations Figure 3-3 Horizontal rack mounting configurations for 7360 ISAM FX-8 in a 23 in. rack 22.313 21.500
03
04
05
06
07
08
35 RU
NTB NTIO NTA
7360 ISAM FX-8
B-40A
Energy Hazard
Energy Hazzard
Alarms
NTA
GND NTB BITS
FAN
Critical Major Minor
A-40A
External Alarms
7360 ISAM FX-8
01
02
8 RU
TOD/IHZ
Remote Craft
BAT A BAT B
ACO
22734
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
3-7
3 — Rack mounting configurations
3.5
7360 ISAM FX-4 rack mounting configurations This section describes the 7360 ISAM FX-4 rack mounting configurations. The 7360 ISAM FX-4 shelf can be installed:
• horizontally in an EIA standard 19 in. rack • horizontally in a 23 in. rack Note — A 19 in. seismic rack with a 17.5 in. shelf aperture between the uprights is not supported.
Table 3-4 lists the supported horizontal rack mounting configurations for 7360 ISAM FX-4 shelves. Table 3-4 Horizontal rack mounting configurations for 7360 ISAM FX-4 Rack unit (1)
19 in. EIA rack horizontal mount
23 in. rack horizontal mount
SR 1
NFXS-F
NFXS-F
Shelf mounting kit
Shelf mounting kit
Fan 1 SR 2
Fan 2
AFAN-X
AFAN-X
(with fan filter)
(with fan filter)
NFXS-F
NFXS-F
Shelf mounting kit
Shelf mounting kit
AFAN-X
AFAN-X
(with fan filter)
(with fan filter)
Note (1)
Although only two rack units are portrayed in this table, up to seven rack units are supported.
Figure 3-5 shows the 7360 ISAM FX-4 horizontal rack mounting configurations in an EIA standard 19 in. rack.
3-8
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
3 — Rack mounting configurations Figure 3-4 Horizontal rack mounting configurations for 7360 ISAM FX-4 in an EIA standard 19 in. rack 18.312 17.750
NTIO
5 RU
NTA
7360 ISAM FX-4
NTB
01
02
03
04
38 RU
External Alarms
BITS
N594
7360 ISAM FX-4
NTA GND NTB
TOD/IHZ
Remote Craft
BAT A BAT B FUSE A B 1 2 3
Critical Alarms Major ACO Minor
FAN
22740
Figure 3-5 shows the 7360 ISAM FX-4 horizontal rack mounting configurations in a 23 in. rack.
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
3-9
3 — Rack mounting configurations Figure 3-5 Horizontal rack mounting configurations for 7360 ISAM FX-4 in a 23 in. rack 22.313 21.500
02
03
04
38 RU
NTIO NTA
7360 ISAM FX-4
NTB
01
5 RU
External Alarms
BITS
N594
7360 ISAM FX-4
NTA GND NTB
TOD/IHZ
Remote Craft
BAT A BAT B FUSE A B 1 2 3
Critical Alarms Major ACO Minor
FAN
22738
3-10
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
4 — Optical modules
4.1 Overview
4-2
4.2 Characteristics
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
4-2
4-1
4 — Optical modules
4.1
Overview This chapter describes the Alcatel-Lucent approved SFP and XFP optical modules for the 7360 ISAM FX.
4.2
Characteristics Table 4-1 describes the Alcatel-Lucent approved optical modules for the 7360 ISAM FX. See Chapter 6, Table 6-12 for part numbers and the cards that these modules support. Table 4-1 Characteristics of approved optical modules
Part number
Description
Wavelength (nm)
Operating case temperature range
Optical budget (dB)
Reach
Fiber
Bidi / uni
UDS(1)
1310
−40°C to 85°C
12
0.550 km
MM
Uni
DAAA
SM
Uni
SM
Bidi
SM
Bidi
SM
Bidi
Cat5
—
PAAA
Cat5
—
EAAA
Cat5
—
MM
Uni
SM
Uni
SM
Uni
SM
Uni
Fast Ethernet SFPs 3FE 25777 AA
FE-FX
−40°F to 185°F 3FE 25778 AA
FE-LX10
1310
−40°C to 85°C
0.342 mi 16
−40°F to 185°F 3FE 29194 AA 3FE 29194 BA 3FE 29195 AA 3FE 63343 AA
FE BX10-D FE BX10-D FE BX10-U 100Base-T
Tx: 1550
−40°C to 85°C
Rx: 1310
−40°F to 185°F
Tx: 1490
−40°C to 85°C
Rx: 1310
−40°F to 185°F
Tx: 1310
−40°C to 85°C
Rx: 1550
−40°F to 185°F
—
0°C to 70°C
15 km 9.3 mi
14
10 km
FAAA
6.2 mi 14
10 km 6.2 mi
14
10 km 6.2 mi
—
32°F to 188°F
0.100 km 0.062 mi
Copper SFPs 3FE 28784 AA
1000Base-T
—
0°C to 85°C
—
32°F to 188°F 3FE 64927 AA
1000Base-T
—
−40°C to 85°C
0.10 km 0.06 mi
—
−40°F to 185°F
0.10 km 0.06 mi
Gigabit Ethernet SFPs 3FE 25773 AA
GE-SX
850
−40°C to 85°C
7
−40°F to 185°F 3FE 25774 AA
GE-LX
1310
−40°C to 85°C
11
−40°F to 185°F 3FE 25775 AA
GE-EX
1310
−40°C to 85°C
GE-ZX
1550
−40°C to 85°C
CAAA
10 km 6.2 mi
18
−40°F to 185°F 3FE 25776 AA
0.55 km 0.34 mi
40 km 24.9 mi
24
−40°F to 185°F
80 km 49.7 mi
(1 of 4)
4-2
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
4 — Optical modules
Part number
Description
Wavelength (nm)
Operating case temperature range
Optical budget (dB)
Reach
Fiber
Bidi / uni
UDS(1)
3FE 25771 AA
GE-YX CWDM (24 dB)
1471
−40°C to 85°C
22
62
SM
Uni
AAAA
1491
−40°F to 185°F
31
120
SM
Uni
10 km
SM
Bidi
SM
Bidi
SM
Bidi
SM
Bidi
Cat5
—
3FE 25771 AB 3FE 25771 AC
1511
3FE 25771 AD
1531
3FE 25771 AE
1551
3FE 25771 AF
1571
3FE 25771 AG
1591
3FE 25771 AH
1611
3FE 25771 CA 3FE 29549 CA
GE-VX CWDM (32 dB)
1471
−5°C to 85°C
1491
32°F to 185°F
3FE 29550 CA
1511
3FE 29551 CA
1531
3FE 29552 CA
1551
3FE 29553 CA
1571
3FE 29554 CA
1591
3FE 29555 CA
1611
3FE 25772 AA 3FE 25772 AB 3FE 28785 AA 3FE 25785 AB 3FE 28784 AA
GE-BX10-U GE-BX10-D GE-BX40-U GE-BX40-D 1000Base-T
Tx: 1310
−40°C to 85°C
Rx: 1490
−40°F to 185°F
Tx: 1490
−40°C to 85°C
Rx: 1310
−40°F to 185°F
Tx: 1310
−40°C to 85°C
Rx: 1550
−40°F to 185°F
Tx: 1550
−40°C to 85°C
Rx: 1310
−40°F to 185°F
—
0°C to 85°C 32°F to 188°F
9
GAAA
6.2 mi 9
10 km 6.2 mi
19
40 km 24.9 mi
19
40 km 24.9 mi
—
0.100 km
EAAA
0.062 mi
SFP+s (2 of 4)
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
4-3
4 — Optical modules
Part number
Description
Wavelength (nm)
Operating case temperature range
Optical budget (dB)
Reach
Fiber
Bidi / uni
UDS(1)
3FE 62600 AA
10 GE-R
1310
−40°C to 85°C
10
10 km
SM
Uni
MAAA
SM
Uni
SM
Uni
SM
Uni
MM
Uni
MM
Uni
SM
Uni
SM
Uni
—
Uni
XAAA
SM
Bidi
TAAA
SM
Bidi
SM
Bidi
SM
Bidi
SM
Bidi
−40°F to 185°F 3FE 62600 CA
10 GE-R
1310
−5°C to 85°C
6.2 mi 10
32°F to 185°F 3FE 62600 DA
10 GE-R
1310
0°C to 70°C
6.2 mi 10
32°F to 188°F 3FE 62600 EA
10 GE-R
1310
−40°C to 85°C
10 GE-R
850
0°C to 70°C
10
10 GE-R
850
−40°C to 85°C
11
10 GE-R
1550
−40°C to 85°C
11
10 GE-R
1550
−40°C to 85°C
0.3 km 0.19 mi
15
−40°F to 185°F 3FE 65832 AA
0.3 km 0.19 mi
−40°F to 185°F 3FE 65831 AA
10 km 6.2 mi
32°F to 188°F 3FE 63264 AA
10 km 6.2 mi
−40°F to 185°F 3FE 65608 AA
10 km
40 km 24.9 mi
24
−40°F to 185°F
80 km 53.3 mi
E1 SFPs 3FE 67231 AA
E1/T1 SFP
—
−40°C to 65°C
—
−40°F to 149°F
E1/T1: short haul 0.5 km 0.31 mi E1/T1: long haul 2.1 km 1.3 mi
Dual SFPs 3FE 65106 AA 3FE 65106 DA 3FE 65107 AA 3FE 65107 DA 3FE 66131 AA
GE-BX10-D GE-BX10-D FE-BX10-D FE-BX10-D
Tx: 1490
−40°C to 85°C
Rx: 1310
−40°F to 185°F
Tx: 1490
0°C to 70°C
Rx: 1310
32°F to 188°F
Tx: 1550
−40°C to 85°C
Rx: 1310
−40°F to 185°F
9
10 km 6.2 mi
9
10 km 6.2 mi
14
10 km 6.2 mi
Tx: 1550
0°C to 70°C
Rx: 1310
32°F to 188°F
14
10 km
FE-BX10-D
Tx: 1490
−40°C to 85°C
8 (FE)
10 km
GE-BX10-D
Rx: 1310
−40°F to 185°F
9 (GE)
6.2 mi
6.2 mi
(3 of 4)
4-4
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
4 — Optical modules
Part number
Description
Wavelength (nm)
Operating case temperature range
Optical budget (dB)
Reach
Fiber
Bidi / uni
3FE 66131 DA
FE-BX10-D
Tx: 1490
0°C to 70°C
9
10 km
SM
Bidi
GE-BX10-D
Rx: 1310
32°F to 188°F
1000BaseBX10
6.2 mi
SM
Bidi
SM
Bidi
SM
Bidi
SM
Bidi
SM
Bidi
UDS(1)
8 100BaseBX10 GPON SFP 3FE 53441 AA 3FE 53441 AC 3FE 53441 BA 3FE 53441 CC 3FE 53441 DA
Class B+, normal
Tx: 1490
−5°C to 70°C
Rx: 1310
23°F to 188°F
Class B+, normal
Tx: 1490
−40°C to 85°C
Rx: 1310
−40°F to 185°F
Class C+, normal
Tx: 1490
−5°C to 70°C
Rx: 1310
23°F to 188°F
Class B+ with OTDR
Tx: 1490
−40°C to 85°C
Rx: 1310
−40°F to 185°F
Class C+, with OTDR
Tx: 1490
−5°C to 70°C
Rx: 1310
23°F to 188°F
XG-PON1 OLT XFP
Tx: 1577
−5°C to +70°C
Rx: 1270
+23°F to +185°F
XG-PON1 ONU SFP+
Tx: 1577
−40°C to +85°C
Rx: 1270
−40°F to +185°F
TM1 SFP
—
−40°C to 70°C
28
30 km
RAAA
18.6 mi 28
30 km 18.6 mi
32
60 km 37.3 mi
28
30 km 18.6 mi
32
60 km 37.3 mi
XG-PON XFPs/SFPs 3FE 53971 AA
3FE 53972 AA
29 dB
40 km
SM
Bidi
29 dB
40 km
SM
Bidi
SM
Uni
YAAA
Other 3FE 66247 AA
28
WAAA
−40°F to 158°F (4 of 4) Note (1)
For more information about the characteristics of the SFP module, see UDS 3HH 01046 xxxx TQZZA, where xxxx is the document variant indicated in this column.
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
4-5
4 — Optical modules
4-6
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
Planning and ordering 5 — Planning the equipment 6 — Ordering the equipment
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
5 — Planning the equipment
5.1 Overview
5-2
5.2 Network considerations
5-2
5.3 Rack considerations
5-4
5.4 Shelf considerations
5-4
5.5 LT card considerations
5-5
5.6 NT card considerations
5-5
5.7 V-OLT and video coupler equipment considerations 5.8 Installation considerations 5.9 Power considerations
5-7
5-8
5.10 Maintenance considerations 5.11 Software licensing information 5.12 Documentation
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
5-5
5-8 5-8
5-8
5-1
5 — Planning the equipment
5.1
Overview This chapter provides planning considerations for ordering the 7360 ISAM FX equipment. Consider the following items when determining what you need:
• • • • • • • • •
5.2
required number and type of shelves rack requirements shelf power and mounting accessories shelf hardware kits and shelf add-on kits installation-related items, such as power and alarm equipment expansion configuration requirements software licensing documentation other requirements, such as MTA, ITSC, and BITS
Network considerations This section describes the 7360 ISAM FX network equipment considerations including system planning. The 7360 ISAM FX is implemented in an access network topology that extends optical access across the last mile of the communications network to the subscriber using fiber optic cable to provide services from the network to residential or business subscribers. The 7360 ISAM FX access network consists of four distinct equipment types:
• P-OLT, which includes the rack and shelves, and the corresponding NT and LT cards • V-OLT, which distributes RF overlay video signals across the GPON if the network provider chooses this method for providing video services • WDM, which is only required to support the V-OLT, and is used to mix and separate the RF video signals to and from the optical fiber going toward ONUs. • ONU, which is located at the subscriber premises as distributed end-points of the access network. This equipment implements the GPON protocol and adapts GPON PDUs to subscriber service interfaces. When planning the installation of the 7360 ISAM FX in an access network, consider the following requirements:
• type of services that will be provided to subscribers • number of ONUs required for each type of subscriber: • estimated number of single-family subscribers • estimated number of multi-dwelling subscribers • estimated number of SOHO subscribers • estimated number of business subscribers with CES (DS1 or E1) requirements • number of LT ports per LT card type • number of NT ports per NT card type • number of LT cards per shelf type: 16, 8, or 4 5-2
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
5 — Planning the equipment
• rack and rack configurations • number of shelves per rack configuration • system capacity restrictions System planning for indoor, outdoor, and business ONTs Use the following steps to calculate the system requirements to support the number of expected subscribers. 1
ONTs — Estimate the number of subscribers. One ONT is required for each subscriber. The number of indoor or outdoor ONTs equals the number of subscribers. The number of SOHO outdoor ONTs or business ONTs equals the number of subscribers.
2
LT ports— Divide the number of indoor or outdoor ONTs by the number of subscribers per LT port (for example, 32 or 64 based on a 1:32 or 1:64 split) to determine how many LT ports are required.
3
Microspan MS-R and MS-C — Determine the required units based on CES requirements of subscribers. See the appropriate Litespan and Microspan user documentation for more information.
4
LTs — Divide the number of LT ports required by the number of LT ports on the LT card to determine the total number of LT cards required.
5
Shelves — Divide the number of LT cards by 16, 8, or 4 to determine how many 7360 ISAM FX-16, 7360 ISAM FX-8, or 7360 ISAM FX-4 shelves are required, respectively.
6
Racks — Divide the number of shelves by the number of shelves per rack to determine the number of racks required.
System planning for modular ONTs Use the following steps to calculate the system requirements to support the number of expected subscribers. 1
Modular ONTs — Estimate the number of subscribers. Each modular ONT can support 12 subscribers. Divide the total number of subscribers by 12 to determine the number of modular ONTs required.
2
LT ports— Divide the number of modular ONTs by 8 to determine how many LT ports are required. The 7360 ISAM FX system typically supports 8 modular ONT units for each LT port.
3
LTs — Divide the number of LT ports required by the number of LT ports on the LT card to determine the total number of LT cards required.
4
Shelves — Divide the number of LT cards by 16, 8, or 4 to determine how many 7360 ISAM FX-16, 7360 ISAM FX-8, or 7360 ISAM FX-4 shelves are required, respectively.
5
Racks — Divide the number of shelves by the number of shelves per rack to determine the number of racks required.
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
5-3
5 — Planning the equipment
5.3
Rack considerations This section identifies the number of shelves that can be accommodated in a rack by rack size and rack mounting configuration; see Table 5-1. See section 6.2 for more information about rack mounting configurations. Table 5-1 Number of shelves per rack
Rack
Rack mounting configuration
7360 ISAM FX-16
7360 ISAM FX-8
7360 ISAM FX-4
23 in. rack
Horizontal mounting
—
4
7
Vertical mounting
2
—
—
Horizontal mounting
—
4
7
19 in. EIA standard rack
5.4
Shelf considerations This section identifies the 7360 ISAM FX shelf equipment required including references to ordering information. For each shelf, consider the number and type of:
• • • • • • •
NT units required LT slots that the shelf can accommodate (16, 8, or 4) LT units for the required types of subscriber services dummy front panels required for any unused slots in the shelf existing and required spare plug-in units SFP and XFP modules required for network and expansion links required cables, such as power harnesses
Table 5-2 lists the types of plug-in units including SFP and XFP modules, and cables for the 7360 ISAM FX shelves, and where to find ordering information. Table 5-2 Ordering plug-in units and cables for the 7360 ISAM FX shelves Type of orderable item
See section
Plug-in units
5-4
GFCs
Section 6.4
Fan units and fan filters
Section 6.5
NT units and dummy front panels
Section 6.6
LT units and dummy front panels
Section 6.8
SFP and XFP modules
Section 6.9
Cables
Section 6.10
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
5 — Planning the equipment
5.5
LT card considerations This section identifies the number of LT ports per LT card; see Table 5-3. Table 5-3 Number of LT ports per LT card LT card
Number of LT ports
NGLT-A
8 GPON ports
NELT-B
36 GE or FE channels 18 GE or FE SFP channels
5.6
NT card considerations This section identifies the number of NT ports per NT card; see Table 5-4. Table 5-4 Number of NT ports per NT card NT card
Number of NT ports
FANT-F
1 10Mbps, 100Mbps, or GE Base-T ports 4 10 GE SFP+ ports 1 ToD/1PPS RJ-45 connection port 1 10 MHz GPS SMA connection port 1 PPS SMA connection port 1 Local craft serial connection port
5.7
V-OLT and video coupler equipment considerations This section identifies the 7360 ISAM FX V-OLT and video coupler equipment, ordering, and installation considerations. If the V-OLT function is required, order both the V-OLT equipment and the video coupler equipment.
V-OLT equipment The V-OLT equipment consists of EDFAs that can accept 1550 nm wavelength optical signals and split the signals into multiple optical feeds onto the fiber path. Order the appropriate EDFAs. The V-OLT is supplied by third-party vendors. Contact your EDFA representative for information about your EDFA requirements.
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
5-5
5 — Planning the equipment
Video coupler equipment The video coupler equipment contains the following items:
• • • • • •
video coupler rack (standard 23 in. rack) three video coupler shelves, LGX compatible (VCSL) one fiber storage shelf (optional) video coupler WDM cassettes (VCW2), one per LT card two fiber management raceways, one on each side of the VCSLs optical jumper cables to connect LT cards and V-OLT to VCW2, and to provide output from VCW2 to ONUs
Ordering considerations
Consider the following when ordering the video coupler equipment:
• required cables and connection modules • installation-related items, such as power and alarm equipment normally procured from commercial sources Contact your Alcatel-Lucent sales representative for more information. Installation considerations
Consider the following when planning to install the WDM equipment in a CO location.
• Floor plan Determine the floor plan details:
• • • •
available space floor type overhead support management cable rack equipment
• Subscribers Determine the number of subscribers who require the radio frequency (RF) video services delivered through the V-OLT. • Optical fiber requirements Determine the optical fiber requirements for video lead from head-end equipment to the V-OLT. The following is required:
• number of connections • run lengths • connectors for termination Note — Alcatel-Lucent recommends that in the fiber distribution
network, APC-based or spliced connectors are used to avoid potential problems. In particular, splitters should be configured so that unused ports are terminated into APC-based connectors.
5-6
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
5 — Planning the equipment
5.8
Installation considerations This section describes the 7360 ISAM FX equipment installation considerations for required space, floor plan, alarms, access, power and ground cable, and optical fiber. The 7360 ISAM FX is typically installed in a CO environment. The following subsections describe items to consider when planning the installation of the 7360 ISAM FX in the CO.
Space Planners should determine the space requirement based on the number of shelves and racks required. If existing racks are to be used, verify space availability.
Floor plan Collect the following floor plan information:
• • • •
measurements of the available space, including height, width, and length floor type overhead support arrangement cable and rack requirement
Alarms Determine the alarm termination requirements. Determine the total number of alarms, and the number and types of connections required.
Access The remote craft port to perform operations and maintenance is connected to the front on the GFC panel.
Power and ground cable Determine the power and ground cable requirements. Collect information about the following:
• number of connections • run lengths and required wire gauge • termination requirements, such as lugs
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
5-7
5 — Planning the equipment
Optical fiber Determine the optical fiber requirements. Collect information on the following:
• number of connections • run lengths • termination requirements, such as connector types Note — Alcatel-Lucent recommends that in the fiber distribution
network, APC-based or spliced connectors are used to avoid potential problems. In particular, splitters should be configured so that unused ports are terminated into APC-based connectors.
5.9
Power considerations See the 7360 ISAM FX Safety Manual for the maximum power consumption per unit. Use the maximum power consumption figures to plan for power sizes required.
5.10
Maintenance considerations This section describes the 7360 ISAM FX maintenance considerations when ordering equipment. Order spare cards to support normal maintenance activities associated with the 7360 ISAM FX. The number of spares needed for each card type is determined by maintenance practices and equipment failure rates. Generally, a minimum of one spare card of each type used is recommended for CO maintenance personnel.
5.11
Software licensing information Software licensing information is included when you purchase the software kits and licenses. Contact your Alcatel-Lucent sales representative for current part numbers for software kits and licenses.
5.12
Documentation Customer documentation is available for download by registered customers from http://www.alcatel-lucent.com/myaccess. If you are a new user and require access to this service, contact your Alcatel-Lucent sales representative. See Table 1 in the Preface for a list of the documents in the documentation set for the 7360 ISAM FX.
5-8
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
6 — Ordering the equipment
6.1 Overview
6-2
6.2 Racks and mounting parts 6.3 Shelves 6.4 GFCs
6-3
6-6 6-7
6.5 Fan units and fan filters
6-8
6.6 NT card and dummy front panel
6-9
6.7 NTIO card and dummy front panel
6-10
6.8 LT cards and dummy front panels
6-10
6.9 Optical modules 6.10 Cables
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
6-11
6-13
May 2012
6-1
6 — Ordering the equipment
6.1
Overview This chapter provides part number information about the 7360 ISAM FX equipment. Table 6-1 lists the orderable items or collection of items, and identifies with a check mark the shelf to which an item or collection of items applies. Table 6-1 7360 ISAM FX equipment Type
Item
FX-16
Racks and mounting parts
7360 ISAM FX-16 mounting
✓
7360 ISAM FX-8 mounting
FX-8
✓
7360 ISAM FX-4 mounting Shelves
NFXS-D
✓ ✓
NFXS-E
✓
NFXS-F GFCs
✓
NGFC-H
✓
NGFC-G Fan units and fan filters
FX-4
✓
AFAN-H
✓
AFAN-E
✓
AFAN-X
✓
NT card and dummy front panel
FANT-F
✓
✓
✓
NT dummy front panel
✓
✓
✓
NTIO card and dummy front panel
NTIO dummy front panel
✓
✓
✓
LT cards and dummy front panels
NGLT-A
✓
✓
✓
NELT-B
✓
✓
✓
LT dummy front panel
✓
✓
✓
Fast Ethernet SFPs
✓
✓
✓
Gigabit Ethernet SFPs
✓
✓
✓
SFP+s
✓
✓
✓
E1 SFP
✓
✓
✓
Dual SFPs
✓
✓
✓
GPON SFPs
✓
✓
✓
XG-PON XFPs/SFPs (XFP/SFP+)
✓
✓
✓
Other
✓
✓
✓
Optical modules
Note 1 — See the corresponding unit data sheet tor more information about a specific orderable item. Note 2 — The term dummy front panel is synonymous with the ANSI
term filler plate. 6-2
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
6 — Ordering the equipment
6.2
Racks and mounting parts This section identifies the parts and part numbers for rack-mounted parts. You can mount the 7360 ISAM FX-16 shelf in a 23 in. rack, and the 7360 ISAM FX-8 and 7360 ISAM FX-4 in a 23 in. or 19 in. EIA standard rack. The 6-2 lists the supported rack mounting configurations by shelf type and rack size. For more information about the rack mounting configurations, see 7360 ISAM FX Hardware Installation Manual. Table 6-2 Rack mounting configurations
Shelf
Rack size
Rack mounting configurations
7360 ISAM FX-16
23 in.rack
Vertical mounting with baffles
7360 ISAM FX-8
EIA standard 19 in. rack (17.75 in. I.D.)
Horizontal mounting
23 in. rack
Horizontal mounting with brackets
EIA standard 19 in. rack (17.75 in. I.D.)
Horizontal mounting
23 in. rack
Horizontal mounting with brackets
7360 ISAM FX-4
Table 6-3 identifies the part number for the 23 in. rack. Table 6-3 Racks Rack
Part number
23 in. rack
1AD 01412 0044
Table 6-4 lists the 7360 ISAM FX equipment orderable at the FEMA code level. The required mounting parts listed are included in the shipment under one part number. Table 6-4 FEMA level rack mounting parts for 7360 ISAM FX-16 Type
FEMA code (1)
Part
Part number
Quantity
7360 ISAM FX-16 mounting (1 of 2)
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
6-3
6 — Ordering the equipment
Type
FEMA code (1)
Part
Part number
Quantity
7360 ISAM FX-16 - rack with one shelf
3FE 66742 AA
23 in. rack
1AD 01412 0044
1
NFXS-D shelf
3FE 65209 BA
1
FX-16 left mounting bracket
3FE 54168 AA
1
FX-16 right mounting bracket
3FE 54168 AB
1
FX-16 fiber and heat baffle kit
3FE 67225 AA
1
12 × 24 1/2in. (12 mm) hex screws
1AD112490001
10
12 × 24 1/2in. (12.7 mm) hex screws
1AD008180005
14
Fan with fan filter
3EC 37533 NB
1
23 in. rack
1AD 01412 0044
1
NFXS-D shelf
3FE 65209 BA
2
FX-16 left mounting bracket
3FE 54168 AA
2
FX-16 right mounting bracket
3FE 54168 AB
2
FX-16 fiber and heat baffle kit
3FE 67225 AA
2
12 × 24 1/2in. (12 mm) hex screws
1AD112490001
20
12 × 24 1/2in. (12.7 mm) hex screws
1AD008180005
28
Fan with fan filter
3EC 37533 NB
2
7360 ISAM FX-16 - rack with two shelves
3FE 66742 AB
(2 of 2) Note (1)
See the 7360 ISAM FX Product Information Guide or the 7360 ISAM FX Hardware Installation Manual for FEMA level and other rack mounting configuration details.
Table 6-5 identifies the orderable mounting parts required for 7360 ISAM FX-8 and 7360 ISAM FX-4. The rack mounting parts are ordered separately. Table 6-5 Rack mounting parts for 7360 ISAM FX-8 and 7360 ISAM FX-4 Rack size
Rack mounting configuration
Part
Part number
Quantity
7360 ISAM FX-8 mounting (1 of 3)
6-4
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
6 — Ordering the equipment
Rack size
Rack mounting configuration
Part
Part number
Quantity
19 in. rack
Horizontal mounting of the 7360 ISAM FX-8 in an EIA standard 19 in. rack (17.75 in. I.D.)
NFXS-E
3FE 64936 BA
1
Horizontal shelf mounting kit (1)
3FE 67300 AA
1
12-24 x 12.7 mm screws
1AD002300017
16
Fan unit
3FE 65060 AA
1
Fan filter
3FE 64928 BA
1
NFXS-E
3FE 64936 BA
1
Horizontal shelf mounting kit
3FE 67300 AA
1
Left and right horizontal brackets
3FE 67313 AA
2
12-24 x 12.7 mm screws
1AD002300017
16
Fan unit
3FE 65060 AA
1
Fan filter
3FE 64928 BA
1
23 in. rack
Horizontal mounting of the 7360 ISAM FX-8 in a 23 in. rack
(2 of 3)
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
6-5
6 — Ordering the equipment
Rack size
Rack mounting configuration
Part
Part number
Quantity
NFXS-F
3FE 64991 BA
1
Horizontal shelf mounting kit (1)
3FE 67299 AA
2
12-24 x 12.7 mm screws
1AD002300017
16
Fan unit
3FE 64994 AA
1
Fan filter
3FE 64928 CA
1
NFXS-F
3FE 64991 BA
1
Horizontal shelf mounting kit
3FE 67299 AA
2
Left and right horizontal brackets
3FE 67312 AA
2
12-24 x 12.7 mm screws
1AD002300017
10
Fan unit
3FE 64994 AA
1
Fan filter
3FE 64928 CA
1
7360 ISAM FX-4 mounting 19 in. rack
23 in. rack
Horizontal mounting of the 7360 ISAM FX-4 in an EIA standard 19 in. rack (17.75 in. I.D.)
Horizontal mounting of the 7360 ISAM FX-4 in a 23 in. rack
(3 of 3) Note (1) Only kit screws required for horizontal installation in 19 in. rack.
6.3
Shelves This section lists the orderable variants of the 7360 ISAM FX shelf equipment; see Table 6-6. Table 6-6 Orderable 7360 ISAM FX shelves
Component
Mnemonic
Part number
7360 ISAM FX-16 shelf, 48 V only, excluding fan unit
NFXS-D
3FE 65209 BA
Includes required mounting brackets and screws
Description NFXS-D:
• • • • • • •
mounts vertically in a 23 in.rack allows for two NT cards and one NTIO card to be mounted in the middle slots of the card cage allows for flexible LT card mounting, meaning that several types of cards can be housed in the LT slots supports 48 V nominal power input voltage levels (± 20% tolerance) contains a field-replaceable fan unit and a field-replaceable fan filter has a built-in GFC (PDBP) supports 1+1 NT redundancy
(1 of 2)
6-6
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
6 — Ordering the equipment
Component
Mnemonic
Part number
7360 ISAM FX-8 shelf, 48 V only, including GFC and fan unit. (Fan filter ordered separately)
NFXS-E
3FE 64936 BA
Description NFXS-E:
• • • • • • • •
7360 ISAM FX-4 shelf, 48 V only, including GFC and fan unit. (Fan filter ordered separately)
NFXS-F
3FE 64991 BA
mounts horizontally in a 19 in. EIA standard rack, kit not required. Order screws separately. mounts horizontally in a 23 in. rack, with mounting kit that includes required mounting brackets and screws provides housing for associated interface units, which are plug-in units of 405 x 225 mm (15.94 in. x 8.86 in.) allows for two NT cards and one NTIO card to be mounted in the lower slots of the card cage allows for flexible LT card mounting, meaning that several types of cards can be housed in the LT slots holds a field-replaceable GFC holds a field-replaceable fan unit and a field-replaceable fan filter supports 1+1 NT redundancy
NFXS-F:
• • • • • • • •
mounts horizontally in a 19 in. EIA standard rack, kit not required. Order screws separately. mounts horizontally in a 23 in. rack, with mounting kit that includes required mounting brackets and screws provides housing for associated interface units allows for two NT cards and one NTIO card to be mounted in the lower slots of the card cage allows for flexible LT card mounting, meaning that several types of cards can be housed in the LT slots holds a field-replaceable GFC holds a field-replaceable fan unit and a field-replaceable fan filter supports 1+1 NT redundancy
(2 of 2)
6.4
GFCs This section lists the orderable variants of the GFCs used in the 7360 ISAM FX shelves; see Table 6-7. Note — The 7360 ISAM FX-16 shelf has a built-in GFC that is not field-replaceable.
Table 6-7 Orderable GFCs Component
Mnemonic
Part number
Description
GFC for the 7360 ISAM FX-8 shelf
NGFC-H
3FE 65675 AA
NGFC-H is the power interface part of the 7360 ISAM FX-8 shelf and acts as the interface for inter-rack routing of alarms toward the NT card, for user-defined alarms, as well as for the power-related alarms of the shelf.
(1 of 2)
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
6-7
6 — Ordering the equipment
Component
Mnemonic
Part number
Description
GFC for the 7360 ISAM FX-4 shelf
NGFC-G
3FE 65676 AA
NGFC-G is the power interface part of the 7360 ISAM FX-4 shelf and acts as the interface for inter-rack routing of alarms toward the NT card, for user-defined alarms, as well as for the power-related alarms of the shelf.
(2 of 2)
6.5
Fan units and fan filters This section describes the orderable variants of the fan units and fan filters for the 7360 ISAM FX shelves; see Table 6-8. Note — When installed in a shelf, a fan filter should be changed at least every 3 months depending on conditions.
Table 6-8 Orderable fan units and filters Component
Mnemonic
Part number
Fan with fan filter, 48 V, only for the 7360 ISAM FX-16 shelf
AFAN-H
For fixed speed: 3EC 37533 NB
Description (1)
AFAN-H provides forced air cooling in a 7360 ISAM FX-16 shelf, and has the following features:
• • • • • •
Fan for the 7360 ISAM FX-8 shelf (Fan filter ordered separately)
AFAN-E
3FE 65060 AA
contains eight fixed-speed fans supports nominal voltages: −48 V dc secured to the shelf by screws field-replaceable and can be hot-inserted connected to the shelf backplane via two 15-pin male D-SUB miniature connectors. equipped with fan filter for use in CO environment. This fan filter must be removed when the shelf is used in closed (cabinet-like) environments where such a filter is not applicable and where higher ambient temperatures (higher than 45°C) are expected.
AFAN-E provides forced air cooling in a 7360 ISAM FX-8 shelf, and has the following features:
• • • • • • • •
contains six wide-voltage range, temperature controlled, variable speed fans mounts in the 7360 ISAM FX-8 shelf fan area behind the fan unit cover supports nominal voltages: −48 V dc / −60 V dc contains a fan unit control card, which generates a common fan alarm toward the NT cards (via the NGFC-E) in case of fan failure and lights the fan alarm LED. secured to the 7360 ISAM FX-8 shelf with a screw field-replaceable and can be hot-inserted provides the space and guiding for a field-replaceable fan filter if the fan unit is equipped with fan filter, the fan unit is only suitable for a CO environment
(1 of 2)
6-8
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
6 — Ordering the equipment
Component
Mnemonic
Part number
Description
Fan for the 7360 ISAM FX-4 shelf (Fan filter ordered separately)
AFAN-X
3FE 64994 AA
AFAN-X provides forced air cooling in a 7360 ISAM FX-4 shelf, and has the following features:
• • • • • • • •
Fan filter for the 7360 ISAM FX-8
—
3FE 64928 BA/DA
—
Fan filter for the 7360 ISAM FX-4
—
3FE 64928 CA/EA
—
contains four wide voltage range, temperature controlled, variable speed fans mounts in the 7360 ISAM FX-4 shelf fan area behind the fan unit cover supports nominal voltages:−48 V dc / −60 V dc contains a fan unit control card, which generates a common fan alarm toward the NT cards (by way of the NGFC-F) in case of fan failure and lights the fan alarm LED secured to the 7360 ISAM FX-4 shelf with a screw field-replaceable and can be hot-inserted provides the space and guiding for a field-replaceable fan filter if the fan unit is equipped with fan filter, the fan unit is only suitable for a CO environment
(2 of 2) Note (1) The variable speed fan costs more, but is less noisy at room temperature than the fixed speed fan.
6.6
NT card and dummy front panel This section describes the orderable variant of the NT card and dummy front panel for the NT unit for the 7360 ISAM FX shelves; see Table 6-9. Table 6-9 Orderable NT card and NT dummy front panel
Component
Mnemonic
Part number
Description
480 Gb/s NT with ANSI T1 BITS, SyncE, and IEEE1588 for high-density/high-bandwidth applications, without SFPs (ANSI variant)
FANT-F
3FE 53701 BD
FANT-F card provides optical and electrical connections for Ethernet or Gigabit Ethernet network connectivity to a high-bandwidth IP services network
NT dummy front panel
—
3FE 65651 AA
Dummy front panel for the NT card must be used when the second NT card is not used in the shelf. The same dummy front panel can be used for all FX shelves including 7360 ISAM FX-16, 7360 ISAM FX-8, and 7360 ISAM FX-4.
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
6-9
6 — Ordering the equipment
6.7
NTIO card and dummy front panel This section describes the orderable variant of the NTIO card and the NTIO dummy front panel for the 7360 ISAM FX shelves; see Table 6-10. Note — The 7360 ISAM FX shelves do not use the NTIO card. A dummy front panel must be installed in the NTIO slot on the shelf.
Table 6-10 Orderable NTIO dummy front panel Component
Mnemonic
Part number
Description
NTIO card
—
—
—
NTIO dummy front panel
—
3FE 65651 BA
The same NTIO dummy front panel can be used for all FX shelves including 7360 ISAM FX-16, 7360 ISAM FX-8, and 7360 ISAM FX-4
6.8
LT cards and dummy front panels This section describes the orderable variants of the LT cards and LT dummy front panels for the 7360 ISAM FX shelves; see Table 6-11. Table 6-11 Orderable LT cards and LT dummy front panels
Component
Mnemonic
Part number
Description
8-port GPON LT card with enhanced (downstream) traffic management capabilities
NGLT-A
3FE 64279 AA
NGLT-A is a GPON LT card that can be installed in a 7360 ISAM FX shelf. The NGLT-A provides termination of eight GPON ports (2.488 Gb/s downstream and 1.244 Gb/s upstream). SFP GPON optical modules can be plugged into the NGLT-A card.
8-port GPON LT card with enhanced (downstream) traffic management capabilities
NGLT-C
3FE 67301 AA
NGLT-C is a GPON LT card that can be installed in a 7360 ISAM FX shelf. The NGLT-C provides termination of eight GPON ports (2.488 Gb/s downstream and 1.244 Gb/s upstream). SFP GPON optical modules can be plugged into the NGLT-C card.
P2P GE/FE LT card (36 lines), excluding SFPs
NELT-B
3FE 62543 AA
NELT-B is an FE/GE LT card that has up to 36 FE/GE optical ports for Ethernet access.
16-port GPON LT card with enhanced (downstream) traffic management capabilities
FGLT-A
3FE 66721 AA
FGLT-A is an GPON LT card that can be installed in a 7360 ISAM FX shelf. The FGLT-A provides termination of sixteen GPON ports (2.488 Gb/s downstream and 1.244 Gb/s upstream). SFP GPON optical modules can be plugged into the FGLT-A card.
LT dummy front panel
—
3FE 65005 AA
An LT dummy front panel must be installed in any unused LT slot.
6-10
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
6 — Ordering the equipment
6.9
Optical modules This section lists the orderable variants of the Alcatel-Lucent approved SFP and XFP modules. Table 6-12 identifies with a check mark the card to which an optical module applies. Table 6-12 Orderable optical modules Item
Part number
FANT-F
NELT-B
NGLT-A
NGLT-C
FGLT-A
Fast Ethernet SFPs FE-FX
3FE 25777 AA
✓
FE-LX10
3FE 25778 AA
✓
FE BX10-D
3FE 29194 AA
✓
100Base-T
3FE 63343 AA
✓ Copper SFPs
1000Base-T
3FE 28784 AA
✓
1000Base-T
3FE 64297 AA
✓ Gigabit Ethernet SFPs
GE-SX
3FE 25773 AA
GE-LX
3FE 25774 AA
✓
GE-EX
3FE 25775 AA
✓
GE-ZX
3FE 25776 AA
✓
GE-YX CWDM (24 dB)
3FE 25771 AA
✓
3FE 25771 AB
✓
3FE 25771 AC
✓
3FE 25771 AD
✓
3FE 25771 AE
✓
3FE 25771 AF
✓
3FE 25771 AG
✓
3FE 25771 AH
✓
3FE 2571 CA
✓
3FE 29549 CA
✓
3FE 29550 CA
✓
3FE 29551 CA
✓
3FE 29552 CA
✓
3FE 29553 CA
✓
3FE 29554 CA
✓
3FE 29555 CA
✓
3FE 25772 AA
✓
GE-VX CWDM (32 dB)
GE-BX10-U
✓
✓
(1 of 2)
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
6-11
6 — Ordering the equipment
Item
Part number
FANT-F
NELT-B
GE-BX10-D
3FE 25772 AB
✓
✓
1000Base-T
3FE 28784 AA
✓
✓
GE-BX40-U
3FE 28785 AA
✓
GE-BX40-D
3FE 28785 AB
✓
NGLT-A
NGLT-C
FGLT-A
SFP+s 10 GE-R
3FE 62600 AA
10 GE-R
3FE 62600 CA
10 GE-R
3FE 62600 DA
✓
10 GE-R
3FE 62600 EA
✓
10 GE-R
3FE 65608 AA
✓
10 GE-R
3FE 63264 AA
✓
10 GE-R
3FE 65831 AA
✓
10 GE-R
3FE 65832 AA E1 SFP
2 × E1 SFP
3FE 67231 AA
✓ Dual SFPs
GE-BX10-D
3FE 65106 AA
✓
GE-BX10-D
3FE 65106 DA
✓
FE-BX10-D
3FE 65107 AA
✓
FE-BX10-D
3FE 65107 DA
FE-BX10-D
✓
3FE 66131 AA
(1)
✓
3FE 66131 DA
(1)
✓
GE-BX10-D FE-BX10-D GE-BX10-D GPON SFPs GPON SFP B+
3FE 53441 AA
✓
GPON SFP B+
3FE 53441 AC
✓
✓
✓
GPON SFP C+
3FE 53441 BA
✓
✓
✓
GPON SFP B+ with OTDR
3FE 53441 CC
✓
✓
✓
GPON SFP C+ with OTDR
3FE 53441 DA
✓
✓
✓
XG-PON XFPs/SFPs XG-PON1 OLT XFP
3FE 53971 AA
XG-PON1 ONU SFP+
3FE 53972 AA Other
TM1 SFP
3FE 66247 AA
✓
(2 of 2)
6-12
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
6 — Ordering the equipment Note (1)
This is a dual-rate compact SFP.
6.10
Cables This section describes the orderable cables required for the 7360 ISAM FX equipment installation. See your Alcatel-Lucent sales representative for details about the required cables.
Lugs and lug tool Alcatel-Lucent recommends the following crimp lugs and crimp lug tool:
• Input power lug: 2 AWG, 90C, Burndy YAZ2C-2TC14 or equivalent • 2 AWG 1/4 - 5/8 dual-hole copper lug long barrel peep, uses Burndy Die Code 10. See Burndy catalog for additional tool options. • Input power lug: 2 AWG, 90C, Thomas and Betts 54855BEPH or equivalent • 2 AWG 1/4 - 5/8 dual-hole copper lug long barrel peep, uses Thomas and Betts Die Code 33. See Thomas and Betts catalog for additional tool options.
CO external alarm cables Table 6-13 describes the CO external alarm cables that are orderable showing cable support per shelf type using a checkmark. Table 6-13 Orderable CO external alarm cables Item
Part number
7360 ISAM FX-16
50-pin micro DSUB connector (1)
3EM 22996 XX
✓
50-pin micro DSUB connector, angled head
3EM 22996 AX
7360 ISAM FX-8
7360 ISAM FX-4
✓
✓
Note (1)
See your Alcatel-Lucent representative for the supported cable variant for 7360 ISAM FX-16.
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
6-13
6 — Ordering the equipment
6-14
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
A.
Mnemonics
A.1 Mnemonics overview
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
A-2
A-1
A. Mnemonics
A.1
Mnemonics overview Table A-1 describes the 7360 ISAM FX equipment mnemonics. Table A-1 Equipment mnemonics
A-2
Mnemonic
Description
AFAN-H
7360 ISAM FX-16 fan unit - version H
AFAN-E
7360 ISAM FX-8 fan unit - version E
AFAN-X
7360 ISAM FX-4 fan unit - version X
FANT-F
7360 ISAM FX NT card - version F
FGLT-A
7360 ISAM FX GPON LT card - version A
NELT-B
7360 ISAM FX 36-line FE/GE LT card - version B
NGLT-A
7360 ISAM FX GPON LT card - version A
NGLT-C
7360 ISAM FX GPON LT card - version C
NFXS-D
7360 ISAM FX-16 shelf - version D
NFXS-E
7360 ISAM FX-8 shelf - version E
NFXS-F
7360 ISAM FX-4 shelf - version F
NGFC-G
7360 ISAM FX GFC - version G
NGFC-H
7360 ISAM FX GFC - version H
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
Glossary
7360 ISAM FX
7360 Intelligent Services Access Manager FX A DSLAM that operates in a packet aggregation network. The 7360 ISAM FX enables deployment of triple-play services, such as video on demand, high-definition TV, and broadcast TV services for all subscribers simultaneously.
AFAN-E
7360 ISAM FX-8 fan unit Fan unit for the 8-slot shelf
AFAN-H
7360 ISAM FX-16 fan unit Fan unit for the 16-slot shelf
AFAN-X
7360 ISAM FX-4 fan unit Fan unit for the 4-slot shelf
AMS
Access Management System
ANSI
American National Standards Institute A nonprofit, nongovernmental body supported by over 1000 trade organizations, professional societies, and companies; ANSI was established for the creation of voluntary industry standards.
ATM
Asynchronous Transfer Mode
AWG
American Wire Gauge
BITS
Building Integrated Timing Source A clock that supplies a composite clock timing reference to all other clocks in a building over BITS clock cables
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
GL-1
Glossary
BPA
Backplane Assembly
BRAS
Broadband Remote Access Server
CAT 5e
Category 5 Ethernet
CB
Circuit Breaker
CBN
Common Bonding Network
CC
Cross-Connect
CDRH
Center for Devices and Radiological Health
CEC
Canadian Electrical Code
CEV
Controlled Environmental Vault A temperature- and humidity-controlled underground vault that houses components at a remote location
CFR
Code of Federal Regulation (U.S.)
CLEI
Common Language Equipment Identification A 10-character code used to identify telecommunications equipment. The 10-character structure, outlined in the Telcordia specification, specifies the basic product type, features, source document, and associated drawings and versions. A CLEI code is unique to a specific piece of equipment.
CLI
Command Line Interface
CO
Central Office
CPE
Customer Premises Equipment
CSA
Canadian Standards Association
CT
Craft Terminal
DSLAM
Digital Subscriber Line Access Multiplexer
EDG
Energy Dumping Ground
EIA
Electronics Industries Association
EMAN
Ethernet Metropolitan Area Network
EMC
Electromagnetic Compatibility EMC designates the ability of commodities to function normally in the electromagnetic environment (this ability is termed Electromagnetic Susceptibility [EMS]), and the ability not to generate unbearable electromagnetic interference to other devices and equipment in the same environment (this ability is termed Electromagnetic Interference [EMI]). These two abilities are collectively named EMC.
EMS
GL-2
Element Management System
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
Glossary
EMS manages the components of a network. ESD
Electrostatic Discharge ESD is the rapid discharge of static electricity from one electrically-charged conductor to another of a different potential. An electrostatic discharge can damage integrated circuits found in computer and communications equipment.
FANT-F
Combined NT unit version F
FCC
Federal Communications Commission (U.S.)
FDA
Food and Drug Administration
FE
Fast Ethernet
GE
Gigabit Ethernet Ethernet interface that runs at 1000 Mb/s
GFC
General Facilities Card
GPON
Gigabit Passive Optical Network GPON is a high performance PON technology based on the G.984 series of standards.
IBN
Isolated Bonding Network
ICES
Interference-Causing Equipment Standard (Industry Canada)
IEC
International Electrotechnical Commission
IHub
Intelligent Hub
IPTV
Internet Protocol Video/Television
ISAM
Intelligent Services Access Manager The Intelligent Services Access Manager is an xDSL access multiplexer that operates in a packet aggregation network. The ISAM enables deployment of triple-play services, such as video on demand, high-definition TV, and broadcast TV services for all subscribers simultaneously.
IWF
Interworking Function IWF provides seamless packet transmission between two protocol stacks. For example, IWF can connect an ATM endpoint with a frame relay endpoint using mappings between the two protocol stacks.
LAN
Local Area Network
LIM
Line Interface Module A network terminator for CEPT and T1.
LNWW
Large New Equipment Practise Worldwide
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
GL-3
Glossary
LP
A slot in the NE shelf where an applique is installed
LSM
Line Server Module A more generic term than LIM since it denotes both xDSL line interface modules and any other server application specific module.
LT
Line Termination Equipment that terminates the access line at the network end
NE
Network Element
NEBS
Network Equipment Building Standards
NEC
U.S. National Electrical Code
NELT-B
Ethernet line termination (LT) unit version B
NFXS-D
7360 ISAM FX 16-slot shelf
NFXS-E
7360 ISAM FX 8-slot shelf
NFXS-F
7360 ISAM FX 4-slot shelf
NGFC-G
7360 ISAM FX-4 power unit The power unit of the 4-slot shelf
NGFC-H
7360 ISAM FX-8 power unit The power unit of the 8-slot shelf
NGLT-A
GPON line termination (LT) board with Traffic Manager version A
NSP
Network Service Provider
NT
Network Termination
NTA
Network Termination A
NTB
Network Termination B
NTIO
Network Termination Input/Output
NTR
Network Timing Reference
OAM
Operation, Administration, and Maintenance
OLT
Optical Line Termination
ONT
Optical Network Terminal
ONU
Optical Network Unit
GL-4
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
Glossary
Equipment that provides voice, data, and video services and terminates the ISAM network at a subscriber location. ONUs provide services to a single family home, a business location, or a multi-dwelling residence, such as an apartment complex or condominium. Services can include POTS, high-speed Ethernet, IPTV, and RF video. OSP
Outside Plan
PBA
Printed Board Assembly
PDBP-C
7360 ISAM FX-16 power unit The power unit of the 7360 ISAM FX 16-slot shelf
P-OLT
Packet Optical Line Termination
PON
Passive Optical Network A fiber-based network that uses passive splitters to deliver signals to multiple users
POTS
Plain Old Telephone Service
PVC
Permanent Virtual Circuit A PVC is an ATM end-to-end logical connection between two user/network interfaces. A PVC may pass through several ATM switching NEs.
RAL
Restricted Access Location
RB
Residential-Bridge
RF
Radio Frequency
RFI
Radio Frequency Interference
Rx
Receive
SDH
Synchronous Digital Hierarchy
SELV
Safety Extra Low Voltage A circuit that has no direct connection to a primary power source, but derives its power from either a transformer, converter, or equivalent isolation device, or from a battery. The circuit is designed and protected so that under normal and single fault conditions, its voltages do not exceed a safe value.
SFP
Small Form-factor Pluggable SFP is a specification for a new generation of optical modular transceivers. The devices are designed for use with small form-factor connectors, and offer high speed and physical compactness. The devices are hot-swappable.
SNMP
Simple Network Management Protocol SNMP is a standard protocol for the management of entities in an IP local area network.
SONET
Synchronous Optical Network
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
GL-5
Glossary
SW
Control Software SW is an acronym used for IHub control software
SyncE
Synchronous Ethernet
TL1
Transaction Language 1
TNV
Telecommunications Network Voltage TNV is a secondary circuit for telecommunications networks. TNV complies with IEC 950.
ToD
Time of Day
Tx
Transmit
UL
Underwriters Laboratories, Inc.
VLAN
Virtual Local Area Network
VPLS
Virtual Private LAN Service A type of VPN in which a number of sites are connected in a single bridged domain over an IP network. The services can be from different locations, but they appear to be on the same LAN in VPLS.
VPN
Virtual Private Network
VPRN
Virtual Private Routed Network A network exhibiting at least some of the characteristics of a private network, even though it uses the resources of a public switched network.
VRF
Virtual Routing Forwarder A logical or virtual routing function with associated routing table that can be instantiated in a router capable of supporting IP VPN services
XFP
10-GE small form-factor pluggable An XFP module is a hot-swappable, protocol-independent transceiver, typically operating at 850 nm, 1310 nm, or 1550 nm, for 10 Gb/s SONET/SDH, fiber channel, gigabit Ethernet, 10 gigabit Ethernet and other applications. XFP was developed by the XFP Multi Source Agreement Group.
GL-6
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
Index
Numbers
D
7360 ISAM FX network topology, 1-2 ordering, 5-2 ordering plug-in units, 6-2 rack mounting configurations, 3-2 shelf configurations, 2-4 shelf types, 2-2 supported plug-in units, 2-7
dimensioning cards, 1-17 GPON, 1-22 documentation ordering, 5-8 dummy front panels, 2-8
B
equipment management, 1-16
baffles heat and fiber management, 2-7
C
F fan filters ordering, 6-8 fan units ordering, 6-8 feature descriptions new features, 1-6 fiber management baffles, 2-7 filler plates LT, 6-10 LT cards, 2-8 NT, 6-9 NT cards, 2-8
capabilities IWF, 1-17 cards dimensioning, 1-17 characteristics optical modules, 4-2 SFP, 4-2 CLEI codes, 1-24
Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
E
May 2012
IN-1
Index functional decomposition — ordering
functional decomposition system architecture, 1-7 FX-16 rack mounting configurations, 3-3 FX-4 rack mounting configurations, 3-8 FX-8 rack mounting configurations, 3-5
G general facilities cards; See GFC GFC ordering, 6-7 GPON dimensioning, 1-22
H heat management baffles, 2-7
I IHub system architecture, 1-14 installation mounting kits, 2-6 IWF capabilities, 1-17
L LT cards dummy panels, 2-8 filler plates, 2-8 ordering, 6-10
M management equipment, 1-16 network, 1-14 mounting kits shelf installation, 2-6
IN-2
N Network management, 1-14 network side network topology, 1-5 network termination units; See NT cards network topology 7360 ISAM FX, 1-2 network side, 1-5 subscriber side, 1-3 new features feature descriptions, 1-6 NT cards dummy panels, 2-8 filler plates, 2-8 ordering, 6-9 NT filler plate ordering, 6-9
O ONTs system planning for indoor ONTs, 5-3 system planning for modular ONTs, 5-3 system planning for outdoor ONTs, 5-3 optical modules approved, 4-2 characteristics, 4-2 ordering, 5-2 documentation, 5-8 fan filters, 6-8 fan units, 6-8 filler plate LT, 6-10 NT, 6-9 GFC, 6-7 LT cards, 6-10 LT filler plate, 6-10 NT filler plate, 6-9 NT unit, 6-9 plug-in units, 6-2 SFP modules, 6-11 software, 5-8 V-OLT equipment, 5-5 XFP modules, 6-11 May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
Index P — XFP module
P
system architecture functional decomposition, 1-7 IHub, 1-14 physical decomposition, 1-7 system planning for indoor ONTs, 5-3 for modular ONTs, 5-3 for outdoor ONTs, 5-3
P-OLT connection capacity specifications, 1-23 part numbers documentation, 5-8 fan filters, 6-8 fan units, 6-8 filler plate LT, 6-10 NT, 6-9 GFC, 6-7 LT cards, 6-10 LT filler plate, 6-10 NT filler plate, 6-9 NT unit, 6-9 SFP modules, 6-11 software, 5-8 XFP modules, 6-11 physical decomposition system architecture, 1-7 plug-in units, 2-7
T technical specifications P-OLT connection capacity, 1-23
V V-OLT equipment ordering, 5-5
X XFP module ordering, 6-11
R rack equipment, 3-2 rack mounting configurations, 3-2 FX-16, 3-3 FX-4, 3-8 FX-8, 3-5 redundancy support 1+1 NT, 1-23
S SFP characteristics, 4-2 SFP module ordering, 6-11 shelf configurations, 2-4 shelf types, 2-2 software ordering, 5-8 subscriber side network topology, 1-3 Alcatel-Lucent 7360 ISAM FX R04.04 3FE 54967 AAAA TCZZA Edition 01 ANSI Product Information Guide
May 2012
IN-3
Index
IN-4
May 2012
Alcatel-Lucent 7360 ISAM FX R04.04 Edition 01 3FE 54967 AAAA TCZZA ANSI Product Information Guide
Customer documentation and product support
Customer documentation http://www.alcatel-lucent.com/myaccess Product manuals and documentation updates are available at alcatel-lucent.com. If you are a new user and require access to this service, please contact your Alcatel-Lucent sales representative.
Technical Support http://support.alcatel-lucent.com
Documentation feedback
[email protected]
© 2012 Alcatel-Lucent. All rights reserved. 3FE 54967 AAAA TCZZA Edition 01