Download 3egm037270_en_c_12sv02_datasheet_hw...
MITRAC® - HW-Data Sheets HW Data Sheet 12SV02
Bombardier Transportation GmbH
MVB-PC Access Kit 12SV02 MVB Service Access Kit MITRAC® Bombardier Transportation C&C System Overview The 12SV02 is a MVB access kit for the MITRAC C&C (Control and Communication) system. It exits in several versions with different HW adapter kits for connection to service interfaces or direct connection to the MVB ESD+ or EMD. Tools: e.g. - MITRAC MAVIS - MITRAC Commissioning Tools
SW: - PCMCIA Driver - TCN-SW
12XX03 R0001/R0002 12SV01R0001
PC-Node 500PCC01 (PCMCIA, type 2)
12XX03 3EGM036800
PCNode
B1 B2 PC with PCMCIA slot 12XX04 R0001
B3
Rx MITRAC
B
Tx
A
MICAS-S2
3EH-104078R1 AB Fauf Nr.: CD MVBSA XV C264 A01 E F
qÉãéä~íÉJfÇKW=PbdjMOTQVQaMMPV=oÉîK=|_=gìäó=OMMN
12XX05 R0001
B4
C Fig. 1:
Usage of the 12SV02
3EGM 037270 Rev. C
15.10.2003
Page 1 of 14
MITRAC® - HW-Data Sheets HW Data Sheet 12SV02
Bombardier Transportation GmbH
The main parts of the 12SV02 q TCN-PC SW q PCMCIA Cardware driver q PC-Node card (12SV01 version 1) q MVB HW Adapter Kits (not included in 12SV02 version 1) HW Adapter Kit for EMD with 12XX03 (included in 12SV02 version 10) HW Adapter Kit for ESD+ with 12XX03 (included in 12SV02 version 11) HW Adapter Kit for VCU-6U and LIM with 12XX04 (included in 12SV02 version 20) HW Adapter Kit for Multipurpose with 12XX05 (included in 12SV02 version 30)
Versions of MVB-PC Access Kit -
Generic MVB-PC Access Kit (12SV02 version 1)
-
MVB-PC Access Kit for EMD with 12XX03 (12SV02 version 10)
-
MVB-PC Access Kit for ESD+ with 12XX03 (12SV02 version 11)
-
MVB-PC Access Kit for VCU-6U and LIM with 12XX04 (12SV02 version 20)
-
MVB-PC Access Kit for Multipurpose with 12XX05 (12SV02 version 30)
Data Sheet
Date
Rev.
Status
Resp. Dept.
Abbr.. Date
First issued
06.05.2002
A
Created
PPC/EMTS
Wp
Revised
07.02.2003 15.10.2003
B C
Checked
PPC/EMTS
GH
Approved
PPC/EMST
He
Sign.
File Name 3egm037270_en_c _12sv02_datasheet _hw.doc
We reserve all rights in this document and the object described therein. Duplication, disclosure to third parties or utilization of its contents are prohibited without express permission. Ó Bombardier Transportation GmbH 2003
MVB-PC Access Kit
15.10.2003
Page 2 of 14
MITRAC® - HW-Data Sheets HW Data Sheet 12SV02
Bombardier Transportation GmbH
Contents Page Overview ....................................................................................................... 1 Contents........................................................................................................ 3 1 Functional Description..................................................................................................................4 1.1
Product Structure .......................................................................................................................4
1.2
Detailed Product Structure ........................................................................................................6
2 Device Configuration ....................................................................................................................7 2.1
Installation Instructions ...........................................................................................................10
2.1.1
SW Installation ..................................................................................................................10
2.1.2
HW Installation..................................................................................................................10
2.2
Connection Elements...............................................................................................................10
2.3
Display Elements.....................................................................................................................10
2.4
Control Elements .....................................................................................................................10
2.5
Setting Facilities ......................................................................................................................10
2.6
Maintenance ............................................................................................................................11
3 Technical Data .............................................................................................................................11 3.1
Power Supply...........................................................................................................................11
3.2
Input and Output Signals .........................................................................................................11
3.3
Bus Connections......................................................................................................................11
3.4
Ambient Conditions ................................................................................................................12
3.5
Weight of MVB-PC Access Kits.............................................................................................12
4 Ordering information .................................................................................................................13 4.1
Problem Reports ......................................................................................................................14
5 Definitions and Abbreviations ...................................................................................................14
MVB-PC Access Kit
15.10.2003
Page 3 of 14
MITRAC® - HW-Data Sheets HW Data Sheet 12SV02
Bombardier Transportation GmbH
1 Functional Description The MVB-PC Access Kit connects a Personal Computer with the MITRAC System for several functions like downloading of application SW, uploading of diagnosis data (e.g. with MAVIS) or testing and commissioning support. It includes all HW and SW components, which are necessary for this interface. The kit is available in several versions for interfacing the different MITRAC C&C environments, e.g. -
Access to MVB EMD Access to MVB ESD+ Access to VCU-6U service interface Access to VCU classic Access to VCU Lite Access to MVB FOB, as for commissioning, an optical cable is used to bridge larger distances, e.g. between front and back console room of a locomotive, or for measurements over several wagons in a train
1.1 Product Structure The product has the following structure: (A) generic part, which is applicable for all target specific versions (B) target specific adapter solutions (C) target specific access kits (C) Target specific MVB-PC Access Kit · Documentation · (A) Generic part · (Bx) Target specific part
Page 4 of 14
(A) Generic part · Documentation · TCN-PC SW · PCMCIA Driver · PC-Node Card
15.10.2003
(B) Target Specific part · Documentation · All target specific cables and adapters
MVB-PC Access Kit
MITRAC® - HW-Data Sheets HW Data Sheet 12SV02
Bombardier Transportation GmbH
Fig. 2: Expositon of MVB-PC Access Kit for Multipurpose
MVB-PC Access Kit
15.10.2003
Page 5 of 14
MITRAC® - HW-Data Sheets HW Data Sheet 12SV02
Bombardier Transportation GmbH
1.2 Detailed Product Structure A1.
Identification
Description / Contents
Remark
3EGM037200 R0001
Generic MVB-PC Access Kit
12SV02 R0001
A1.1 3EGM037205 Rxxxx 3EGM037206 Rxxxx
Documentation: data sheet, CD-ROM, installation guide, etc. SW: Cardware Driver from APSoft CD-ROM with PC-Node firmware and TCN-PC-SW
A1.4
3EGM037100 R0001
HW: PC-Node card incl. black cable
Option has to be ordered extra X: actual SW version, install. see ch. 2.1 12SV01 R0001
B1
3EGM036800 R0001
HW Adapter Kit for EMD Access
12XX03 R0001
A1.2 A1.3
B1.1 B1.2 B1.3
B2
Smd suitcase Documentation: 12SV02 data sheet HW: Adapter for EMD access
3EGM036800 R0002
B2.1 B2.2 B2.3
B3
3EGM036700 R0001
3EGM037000 R0001
3BHC380132R0372 3EGM033100R0001 3EGM037007R0001 3EGM037008R0001 3EGM037009R0001
C1
3EGM037200 R0010
C1.1 C1.2 C1.3 C1.4
3EGM037200 R0011
C2.1 C2.2 C2.3 C2.4
C3
3EGM037200 R0020
C3.1 C3.2 C3.3 C3.4
C4
HW Adapter Kit for VCU-6U and LIM service interface
12XX04 R0001
Smd suitcase Documentation: 12SV02 data sheet HW: Adapter for VCU-6U and LIM service interface
B4.1 B4.2 B4.3 B4.5 B4.6 B4.7 B4.8 B4.9
C2
12XX03 R0002
Smd suitcase Documentation: 12SV02 data sheet HW: Adapter for ESD+ access
B3.1 B3.2 B3.3
B4
HW Adapter Kit for ESD+ Access
3EGM037200 R0030
C4.1 C4.2 C4.3 C4.4
HW Adapter Kit for Multipurpose
12XX05 R0001
Smd suitcase Documentation: 12SV02 data sheet HW: Adapter for Multipurpose Optional fiber optical cable, about 2m Adapter VCU to VCU-6U service interface 12XX11 Optional accumulator pack including charger Optional charger for accumulator pack Optional accumulator pack
Option has to be ordered extra Option has to be ordered extra Option has to be ordered extra Spare part Spare part
MVB-PC Access Kit for EMD
12SV02 R0010
Smd suitcase Documentation: 12SV02 data sheet A1 B1
Shall contain everything
MVB-PC Access Kit for ESD+
12SV02 R0011
Smd suitcase Documentation: 12SV02 data sheet A1 B2
Shall contain everything
See above See above
See above See above
MVB-PC Access Kit for VCU-6U and LIM 12SV02 R0020 service interface Smd suitcase Documentation: 12SV02 data sheet A1 B3
Shall contain everything
MVB-PC Access Kit for Multipurpose
12SV02 R0030
Smd suitcase Documentation: 12SV02 data sheet A1 B4
Shall contain everything
See above See above
See above See above
Table 1: Product structure
Page 6 of 14
15.10.2003
MVB-PC Access Kit
MITRAC® - HW-Data Sheets HW Data Sheet 12SV02
Bombardier Transportation GmbH
2 Device Configuration For the connection of the PC-Node HW adapter kit to MITRAC system TRACS compatible connectors with shielded plastic housing are used to prevent short circuit on vehicle. The 12SV02 R0001 is the generic MVB-PC Access kit without any HW adapter for target connection. 20cm PC-Node
Fig. 3:
Device configuration for A1: 12SV02 R0001
The 12SV02 R0010/R0011 is designed for direct connection to MVB EMD (R0010) or ESD+ (R0011). It is needed for an access of MVB segments or targets without any MVB service interface (e.g. DCU). To connect this kit to the MVB, one MVB connector (Sub-D) at a device has to be disconnected and the “Y-cable has to be included there in-between (see Fig. 4:). For MVB EMD a passive T-adapter can be installed permanently on the vehicle. The 12PU03 can be ordered with identification number 3EGM033800R0001. In this case the 12SV02R0010 can be directly connected to this T-Adapter without disconnection of any other connector. direct connection to MVB or 12PU03
PC-Node
5m cable
PS2 mouse adapter cable
PS2 / USB adapter
USB type A connector
Repeater Box
10cm Y-cable
Fig. 4:
Device configuration for B1/B2: 12SV02 R0010 / R0011
MVB-PC Access Kit
15.10.2003
Page 7 of 14
MITRAC® - HW-Data Sheets HW Data Sheet 12SV02
Bombardier Transportation GmbH
The 12SV02 R0020 is designed for direct connection to VCU-6U service interface.
PC-Node
6m cable VCU-6U with service interface
Fig. 5:
Page 8 of 14
Device configuration for B3: 12SV02 R0020
15.10.2003
MVB-PC Access Kit
MITRAC® - HW-Data Sheets HW Data Sheet 12SV02
Bombardier Transportation GmbH
For an access to VCU-Classic and VCU-Lite the 12SV02 R0030 can be used. The 0.5 meter long adapter cable for connection of VCU classic and VCU-Lite, can also be used for MICAS-S2. In addition an optional adapter 12XX11 (order number 3EGM033100R0001) can be used for connection of VCU-6U service interface with this cable. In this case the adapter 12XX11 has to be plugged on VCU-6U service interface.
"Lemo" connector PC-Node
9 V Power supply
6m cable
110-240 V / 50-60Hz Adapter or optional accumulator package
VCU classic
Fig. 6:
MICAS-S2
3EH-104078R1 CD Fauf Nr.: MVBSA XV C264 A01 E F
PC-Node
9 V Power supply
optional 2 * 2m FOB cable
0.5 m cable D-SUB 9 male
MVB Bus coupler VCU classic VCU Lite service interface D-SUB 9 female
Device configuration for B4: 12SV02 R0030
Optional a accumulator package with charger for 12SV02R0030 can be ordered:
7,2 V accu package with "Lemo" connector
110V-240 V / 50Hz-60Hz charger for accu package with "Lemo" connector
Fig. 7:
Device B4.7: Optional accumulator pack with charger for 12SV02 R0030
As spare part the accumulator pack ( see Table 1 B4.9) and the charger (see Table 1 B4.8) can be ordered separately.
MVB-PC Access Kit
15.10.2003
Page 9 of 14
MITRAC® - HW-Data Sheets HW Data Sheet 12SV02
Bombardier Transportation GmbH
2.1 Installation Instructions 2.1.1 SW Installation The MVB-PC Access Kit contains several SW components on CD ROM divided for the different PC operating system WIN NT 4.0 and Win 2000/XP: Win NT 4.0: -
TCN-PC SW for WinNT 4.0 incl. PC-Node Firmware PCMCIA Cardware driver for WinNT
For installation of PCMCIA Cardware driver and TCN-PC SW 2.2.0 for Microsoft Windows NT4.0 see Document 3egm080930d9005_en_tcn_pc_WinNT4_inst_220.pdf which is placed on CD in the directory of TCN-PC SW for WinNT4. Win 2000: -
TCN-PC SW for Win2000 incl. PC-Node Firmware
For installation of TCN-PC SW 2.6 for Microsoft Windows 2000/XP see document 3egm080930d9013_en_tcn_pc_Win2000_inst_260.pdf which is placed on CD in the directory of TCN-PC SW for Win2000/XP.
2.1.2 HW Installation Please see the figures in chapter 2 Device Configuration. Further information can be found in the associated TCN-PC SW installation instructions.
2.2 Connection Elements The connectors of the Access Kit have to fit together as defined in the overview pictures of the different device configurations (see chapter 2 Device Configuration).
2.3 Display Elements The MVB-PC Access Kit itself has no display elements.
2.4 Control Elements Not present
2.5 Setting Facilities All settings will be done via MITRAC PC tools see 2.1 Installation Instructions. Attention: The PC-Node firmware versions are not compatible to both Windows versions NT 4.0 2000/XP all at once. The PC-Node firmware 1.1.0.0 or 1.2.1.0 can only be used with WinNT4 The PC-Node firmware 1.4.0.0 can only be used with Win2000 or XP. Page 10 of 14
15.10.2003
MVB-PC Access Kit
MITRAC® - HW-Data Sheets HW Data Sheet 12SV02
Bombardier Transportation GmbH
Please do not update PC-Node firmware version 1.1.0.0 to 1.2.1.0, if using Win NT 4.0. This is only needed if two PC-Nodes are operating on one MVB at the same time. But some old PC-tools will not work with the new PC-Node firmware because some additional settings have to be done by the PC-tool for correct operation. The PC-Node firmware versions for standard use cases are available on the CD-ROM.
2.6 Maintenance Not present
3 Technical Data 3.1 Power Supply The MVB-PC Access Kits with the HW adapters 12XX03 and 12XX04 are supplied by the PC via PS2-mouse connector card. The MVB-PC Access Kit 12SV02R0030 with the HW adapters 12XX05 requires an external 9V power supply. Therefore a 9V power supply adapter for 110V-240V / 50Hz60Hz is added to this package. Power consumption:
max. 1W
3.2 Input and Output Signals Not present
3.3 Bus Connections 12SV02R0001: Generic Access Kit only, without any MVB connection 12SV02R0010: Access Kit with EMD bus connection 12SV02R0011: Access Kit with ESD+ bus connection For interconnection of this access kit the MVB line has to be disconnected at one MVB device and the MVB Y-Adapter has to be integrated directly in the MVB line. For MVB EMD also the 12PU03 T-branch can be used thus a disconnection of MVB is not necessary. 12SV02R0020: Access Kit with connection to MVB service port at VCU-6U. The cable has to be connected directly on the service connector X22 on VCU-6U or on LIM connector XA22 12SV02R0030: Access Kit with bus connections for VCU-Classic and VCU-Lite (included adapter cable) and optional for MVB FOB (2*FOB cables have to ordered extra)
MVB-PC Access Kit
15.10.2003
Page 11 of 14
MITRAC® - HW-Data Sheets HW Data Sheet 12SV02
Bombardier Transportation GmbH
3.4 Ambient Conditions The Access Kits are applicable for service purpose only, not for permanent operation on vehicles. Operating temperature:
0°C ... + 50°C
Therefore the Access Kit may not be exposed extreme ambient conditions like temperature humidity etc.
3.5 Weight of MVB-PC Access Kits Version 12SV02 R0001 12SV02 R0010 12SV02 R0011 12SV02 R0020 12SV02 R0030
Page 12 of 14
Dimension PCMCIA card with short 15 SUD-D adapter PCMCIA card with 5m cable, potential separation box and 9 SUD-D TRACS compatible Y-adapter (10cm) PCMCIA card with 5m cable, potential separation box and 9 SUD-D TRACS compatible Y-adapter (10cm) PCMCIA card with termination box, 5m cable 9 SUD-D TRACS compatible connector for VCU-6U PCMCIA card with termination box, 5m cable, multipurpose adapter box and 9 SUD-D TRACS compatible adapter (0,5m)
Weight [g] 90g 800g
15.10.2003
MVB-PC Access Kit
800g 350g 1300g
MITRAC® - HW-Data Sheets HW Data Sheet 12SV02
Bombardier Transportation GmbH
4 Ordering information All types of MVB-PC Access Kits can be ordered at: Bombardier Transportation GmbH Propulsion and Controls Department PPC Sales Neustadter Str. 62 68305 Mannheim Germany Fax: +49 62 13 81 52 11 First offer/order will be done typically on level C.x. A1 and B.x are typically used for spare part handling. Identity Number Product Group Product Type Short Description
3EGM037200R0001 MVB-PC Access Kit 12SV02 R0001 Generic MVB-PC Access Kit
Identity Number Product Group Product Type Short Description
3EGM037200R0010 MVB-PC Access Kit 12SV02 R0010 MVB-PC Access Kit for EMD
Identity Number Product Group Product Type Short Description
3EGM037200R0011 MVB-PC Access Kit 12SV02 R0011 MVB-PC Access Kit for ESD+
Identity Number Product Group Product Type Short Description
3EGM037200R0020 MVB-PC Access Kit 12SV02 R0020 MVB-PC Access Kit for VCU-6U and LIM service interface
Identity Number Product Group Product Type Short Description
3EGM037200R0030 MVB-PC Access Kit 12SV02 R0030 MVB-PC Access Kit for Multipurpose
All 12SV02 versions will be delivered in a suitcase.
MVB-PC Access Kit
15.10.2003
Page 13 of 14
MITRAC® - HW-Data Sheets HW Data Sheet 12SV02
Bombardier Transportation GmbH
4.1 Problem Reports If problems occur concerning this document or the product described by this document, please contact: BTPC Hotline Neustadter Straße 62 D-68309 Mannheim Germany Phone: Email:
+49-621-381-4310, -2099
[email protected]
5 Definitions and Abbreviations EMD ESD+ LIM MVB TCN VCU
Page 14 of 14
Electrical Medium Distance Bus Electrical Short Distance Bus with potential separation Line Interference Monitor Multipurpose Vehicle Bus Train Communication Network Vehicle Control Unit
15.10.2003
MVB-PC Access Kit