Verification Document Release Delivery: EX4.1 Product Family: Base Stations Product: Flexi Multiradio Base Station Flexi EDGE Base Station Release: EX4.1

DN086776 Issue 6-0 en

© Nokia Siemens Networks

1 (19)

MENU

Table of Contents 1. 2. 3. 4.

Purpose .......................................................................................................................................... 3 Test Phases and Amount of Test Cases ........................................................................................ 3 Test Environment ........................................................................................................................... 3 Test Results ................................................................................................................................... 3 4.1 Flexi Multiradio BTS Features Functional Test ........................................................................ 3 4.1.1 Macrocellular ....................................................................................................................... 3 4.1.2 Operability............................................................................................................................ 4 4.1.3 Value Added Services ......................................................................................................... 7 4.1.4 Site Solution......................................................................................................................... 7 4.2 Flexi EDGE BTS Features Functional Test .............................................................................. 8 4.2.1 Macrocellular ....................................................................................................................... 8 4.2.2 Operability............................................................................................................................ 8 4.2.3 Value Added Services ....................................................................................................... 10 4.2.4 Site Solution....................................................................................................................... 11 4.3 Platform Independent BTS Features Functional Test ............................................................ 11 4.3.1 Base Stations..................................................................................................................... 11 4.3.2 Base Station Controller ...................................................................................................... 11 4.3.3 Radio Network Performance .............................................................................................. 11 4.3.4 Data ................................................................................................................................... 13 4.3.5 Microcellular....................................................................................................................... 13 4.3.6 Transport and Transmission .............................................................................................. 13 4.4 Flexi Multiradio BTS Maintenance Functional Test ................................................................ 15 4.4.1 BTS Module Replacement ................................................................................................. 15 4.5 Flexi EDGE BTS Maintenance Functional Test ..................................................................... 15 4.5.1 BTS Module Replacement ................................................................................................. 15 4.6 Flexi Multiradio BTS Site Installation validation ...................................................................... 15 4.6.1 BTS Site Expansion ........................................................................................................... 15 4.6.2 BTS Site Commissioning ................................................................................................... 16 4.6.3 Flexi BTS Autoconnection ................................................................................................. 16 4.6.4 BTS Site Rehosting ........................................................................................................... 16 4.7 Flexi EDGE BTS Site Installation validation ........................................................................... 16 4.7.1 BTS Site Expansion ........................................................................................................... 16 4.7.2 BTS Site Commissioning ................................................................................................... 17 4.7.3 Flexi BTS Autoconnection ................................................................................................. 17 4.8 Release Delivery Upgrade Testing ......................................................................................... 17 4.8.1 Software Package Creation and Storage .......................................................................... 17 4.8.2 Software Release Upgrade/Fallback ................................................................................. 17 4.8.3 Installation of 2G Flexi BTS Site Manager ......................................................................... 17 5. Remaining Open Faults Found In Testing .................................................................................... 18 6. Appendices / References ............................................................................................................. 18

Contact: Contact your local Nokia Siemens Networks support, or GSM/EDGE BTS Technical Support: [email protected]

DN086776 Issue 6-0 en

© Nokia Siemens Networks

2 (19)

MENU

1. PURPOSE This document presents the testing results for BTS software release EX4.1 including the findings made. The test environments are also presented in this document.

2. TEST PHASES AND AMOUNT OF TEST CASES Test Phase

Nbr of test cases

Flexi Multiradio BTS Features Functional Test

84

Flexi EDGE BTS Features Functional Test

59

Platform Independent BTS Features Functional Test

75

Flexi Multiradio BTS Maintenance Functional Test

6

Flexi EDGE BTS Maintenance Functional Test

6

Flexi Multiradio BTS Site Installation validation

23

Flexi EDGE BTS Site Installation validation

11

Release Delivery Upgrade Testing

15

Total

279

3. TEST ENVIRONMENT The following table summarizes performed test phase entities and the amount of test cases in corresponding test phase. These cases were executed on representative final release builds of EX4.1 BTS software. Network Element BSC LMUB MGW NetAct PC Operating System

GCS

Release/upgrade/update level S14 EP9.1, S15, S15 EP1.2 CD 8 U5.0 MP1.2 OSS 5.2 MP1, OSS 5.3 CD set 3 Windows 7 32-bit, Windows XP SP2 and SP3, Windows Vista 32-bit SP2 and 64-bit SP2, Windows Server 2008 32-bit and 64-bit R6, R6.1, R6.2

4. TEST RESULTS 4.1 Flexi Multiradio BTS Features Functional Test 4.1.1 Macrocellular Improved Solution for Extended Cell Test Case ID 2.1.1.1

Test Case Title Successful CS calls with handover and PS Data transfer support in

DN086776 Issue 6-0 en

© Nokia Siemens Networks

3 (19)

MENU

2.1.1.2

Extended Cell configuration Reconfiguration Support for E-RACH E-TRX

Mast Head Pre-Amplifier Test Case ID 2.1.2.1 2.1.2.2 2.1.2.3 2.1.2.4

Test Case Title Alarm reporting for Active MHA with bypass configuration Alarm reporting for MHA without bypass Capability Successful commissioning of site (Active MHA connected) and observing its view on BTS Manager Alarm reporting for Passive MHA without bypass configuration

Multi BCF Control Test Case ID 2.1.3.1 2.1.3.2 2.1.3.3 2.1.3.4

Test Case Title BCF Recovery after Master BCF reset BCF Synchronization Recovery when 1PPS cable is removed and connected back from Master BTS site Slave BCF Recovery after reset when clock is missing Slave clock recovery after Sync Cable re-connection

RX Antenna Diversity Test Case ID 2.1.4.1

Test Case Title Rx Level Measurements when Diversity is enabled at startup

4.1.2 Operability Abis Loop Test Test Case ID 2.2.1.1 2.2.1.2

Test Case Title Abis Loop Test for Fixed Abis Configuration Abis Loop Test for CSDAP Circuits from BSC

Autodetection Test Case ID 2.2.2.1

Test Case Title Autodetection of BTS Internal units at Site Startup with ESMx and FXxx HW Module

BTS External Alarms and Control Test Case ID 2.2.3.1 2.2.3.2 2.2.3.3

Test Case Title External Input Line Alarm Control - Reporting route is ACT Verification of External Output Line Control for Flexi Multiradio RF Module EAC lines Verification of Flexi Power Module and EAC Alarms

BTS Local Blocking Test Case ID 2.2.4.1 2.2.4.2

Test Case Title Local BCF Block and Unblock Local BTS Block and Unblock

DN086776 Issue 6-0 en

© Nokia Siemens Networks

4 (19)

MENU

BTS Object Control Test Case ID 2.2.5.1 2.2.5.2 2.2.5.3 2.2.5.4 2.2.5.5 2.2.5.6 2.2.5.7 2.2.5.8

Test Case Title BTS Object Recovery when Flexi Multiradio RF Module carrying BCCH TRX is HW Reset in Antenna Hopping BTS Object behavior when Flexi Multiradio RF Module is HW Reset in Antenna Hopping BTS Object behavior when Flexi Remote Radio Head is HW Reset Alarms Reporting for Missing Flexi Multiradio RF Module at Startup BCF Object reset from 2G Flexi BTS Site Manager with bypass traffic unaffected BTS Object Recovery when Flexi Multiradio RF Module carrying BCCH TRX is HW Reset BTS and TRX Object Administrative State Change from BSC and Forced handover of CS call to another BTS object Successful recovery of Flexi BTS site after perfoming power reset

BTS Supervision Test Case ID 2.2.6.1 2.2.6.2 2.2.6.3 2.2.6.4 2.2.6.5 2.2.6.6 2.2.6.7

Test Case Title Addition Removal of TRX in antenna hopping sector BCCH reconfiguration and O&M Operation in Common BCCH Different BTS operations in antenna hopping enabled sector Reconfiguration Support in an Antenna hopping Sector for Flexi Multiradio BTS Site Smart BCCH Reconfiguration due to disconnection of Flexi MultiRadio RF module Supervision of Flexi Multiradio System Module Fan Unit when Fans are faulty Supervision of Flexi Multiradio RF Module (FXxx) in a 36 TRX BTS Site

GSM LTE RF Sharing Test Case ID 2.2.7.1 2.2.7.2 2.2.7.3 2.2.7.4 2.2.7.5 2.2.7.6

Test Case Title Alarm reporting for missing RP3 link between shared RM module and 2G BTS site in concurrent mode Commissioning a 2G BTS site from standalone mode to concurrent mode Commissioning failed-Peer technology BTS providing Synchronisation to 2G BTS site is powered OFF Disconnection of RP3 sync cable(synchronisation from Peer technology BTS) of 2G Flexi Multiradio BTS site at runtime Successful Commissioning a BTS site in concurrent mod Sync recovery of 2G Flexi Multiradio BTS Site when sync master (Peer technology BTS site) goes for power reset

Intelligent Shutdown Test Case ID 2.2.8.1 2.2.8.2 2.2.8.3

Test Case Title Intelligent Shutdown in Antenna Hopping Intelligent ShutDown of Non-BCCH TRXs Intelligent Shutdown of all (BCCH & non-BCCH) TRXs

DN086776 Issue 6-0 en

© Nokia Siemens Networks

5 (19)

MENU

Modification of BCF Parameters by Append Commissioning Test Case ID 2.2.9.1 2.2.9.2

Test Case Title Upload of SCF from remotely connected 2G Flexi BTS Site Manager Append commissioning from remotely connected 2G Flexi BTS Site Manager

Remote 2G Flexi BTS Site Manager Test Case ID 2.2.10.1 2.2.10.2 2.2.10.3 2.2.10.4 2.2.10.5

Test Case Title Successful execution of TRX test from 2G Flexi BTS Site Manager connected remotely Successful fetch of B2 cross-connection (32k16k8k) from remote 2G Flexi BTS Site Manager Successful fetch of Site Information Report (SIR) from remotely connected 2G Flexi BTS Site Manager Remote BTS Manager access in Read Only mode with different UALC settings Successful connection of 2G Flexi BTS Site Manager via NetAct and display of BTS views

Runtime diagnostics and BTS alarms Test Case ID 2.2.11.1 2.2.11.2

Test Case Title Alarm Handling when ARFN in MA list attached is outside the band capacity for Radio branch Alarms Reporting for Missing Flexi Multiradio RF Module at Startup

RX antenna supervision by comparing RSSI Test Case ID 2.2.12.1

Test Case Title RX antenna supervision by comparing RSSI for Flexi Multiradio BTS site

TRX Power Down Test Case ID 2.2.13.1 2.2.13.2 2.2.13.3 2.2.13.4 2.2.13.5

Test Case Title Automatic TRX Power down with Dynamic Power pooling feature enabled Impact of manual powerdown on 1800 and 900 band TRXs TRX Power-down in low traffic conditions TRX Power-down in low traffic conditions in Antenna Hopping Verification of behavior after Repeated TRX Power down

TRX Test Test Case ID 2.2.14.1 2.2.14.2 2.2.14.3 2.2.14.4

Test Case Title TRX Test Initiated From 2G Flexi BTS Site Manager In Supervisory state TRX Test Initiated From 2G Flexi BTS Site Manager In Supervisory state in dynamic power pooling enabled TRX Test Initiated From BSC TRX Test Initiated From BSC when Ext CCCH is configured at BTS

DN086776 Issue 6-0 en

© Nokia Siemens Networks

6 (19)

MENU

TX Antenna VSWR Supervision Test Case ID 2.2.15.1 2.2.15.2 2.2.15.3 2.2.15.4

Test Case Title VSWR Alarm Handling with Lock/Unlock Operations for TCH antenna with No Ongoing Traffic VSWR Alarm Handling with Lock/Unlock and Block/Unblock Operations VSWR Alarm Handling with Lock/Unlock and Block/Unblock Operations for BCCH antenna VSWR Alarm Handling with Lock/Unlock and Block/Unblock Operations for TCH antenna

4.1.3 Value Added Services Remote Interrogation of Serial and Version Numbers Test Case ID 2.3.1.1 2.3.1.2 2.3.1.3 2.3.1.4

Test Case Title Remote Interrogation of Serial Number & Version Number when Flexi Remote Head Module is replaced Remote Interrogation of Serial Number & Version Number with FXxx module in concurrent mode Remote Interrogation of Serial Number & Version Number After Passive Unit Details are Changed Through Append Commissioning Remote Interrogation of Serial Number & Version Number when Flexi Multiradio RF Module is replaced

Short message cell broadcast without DRX Test Case ID 2.3.2.1

Test Case Title Short message cell broadcast - DRX OFF

Short Message Service Cell Broadcast with DRX Test Case ID 2.3.3.1

Test Case Title Short message cell broadcast - DRX ON

4.1.4 Site Solution Packet TRS for UltraSite / BTSplus Test Case ID 2.4.1.1 2.4.1.2 2.4.1.3 2.4.1.4

Test Case Title Commissioning of Flexi Multiradio BTS providing relay functionality to Ultrasite EDGE Base Station Commissioning of Flexi Multiradio BTS providing synchronisation and relay functionality to BTS Plus Successful handover of CS voice call from Flexi EDGE BTS site and BTS plus and vice versa Verification of alarm mapping of real to virtual E1 or T1 port in Abis over IP Ethernet relay mode

DN086776 Issue 6-0 en

© Nokia Siemens Networks

7 (19)

MENU

4.2 Flexi EDGE BTS Features Functional Test 4.2.1 Macrocellular Improved Solution for Extended Cell Test Case ID 3.1.1.1 3.1.1.2

Test Case Title Reconfiguration Support for BCCH N -TRX with DPTRX Successful CS calls with handover and PS Data transfer support in Extended Cell configuration

Mast Head Pre-Amplifier Test Case ID 3.1.2.1 3.1.2.2

Test Case Title Alarm reporting for MHA with bypass in DDU configuration Alarm reporting for MHA without bypass in RTC configuration

RX Antenna Diversity Test Case ID 3.1.3.1

Test Case Title RX Level Measurements when Diversity is enabled at startup

4.2.2 Operability Abis Loop Test Test Case ID 3.2.1.1

Test Case Title Abis Loop Test For Dynamic Abis

BTS External Alarms and Control Test Case ID 3.2.2.1 3.2.2.2 3.2.2.3

Test Case Title External Input Line Alarm Control - Reporting route is ACT, TMS External Output Line Control Verification of MIBBU Alarm and EAC Alarms

BTS Local Blocking Test Case ID 3.2.3.1 3.2.3.2 3.2.3.3

Test Case Title Local BCF Block and Lock/Unlock Local BTS Block/Deblock Local TRX Block/Deblock

BTS Object Control Test Case ID 3.2.4.1 3.2.4.2 3.2.4.3

Test Case Title BTS Object Behaviour When EXxx TRX Module Controlling ERxx DDU Module is HW Reset BTS Object Recovery when EXxx TRX Module carrying BCCH TRX is HW Reset BTS and TRX Object Administrative State Change from BSC and Forced handover of CS call to another BTS object

DN086776 Issue 6-0 en

© Nokia Siemens Networks

8 (19)

MENU

BTS Supervision Test Case ID 3.2.5.1 3.2.5.2 3.2.5.3 3.2.5.4 3.2.5.5 3.2.5.6 3.2.5.7 3.2.5.8 3.2.5.9 3.2.5.10

Test Case Title Reconfiguration Support in an Antenna hopping Sector Sector Reconfiguration Support in a Baseband Hopping Sector Supervision Of ERxx DDU Module Supervision Of ESMA System Module FAN Unit When Fans Are Faulty Supervision Of ESMA System Module to Central EOCA Optical Converter module unit interface in a Feederless Site Supervision Of EXxx TRX Module FAN Unit When Fans Are Faulty Supervision Of EXxx TRX Module connected to ERxx DDU Module in a 24 TRX BTS Site Supervision Of Q1 Bus Supervision of ECxx RTC Module Supervision of ESEA System Extension Module

Fast BSS Restart Test Case ID 3.2.6.1

Test Case Title Execute Fast BSS restart on multiple sites under different conditions

Intelligent Shutdown Test Case ID 3.2.7.1 3.2.7.2

Test Case Title Intelligent Shutdown of all (BCCH & non-BCCH) TRXs Intelligent Shutdown till BCCH level in DP/4UD configuration

Modification of BCF Parameters by Append Commissioning Test Case ID 3.2.8.1 3.2.8.2

Test Case Title Append commissioning from remotely connected 2G Flexi BTS Site Manager Upload of SCF from remotely connected 2G Flexi BTS Site Manager

Remote 2G Flexi BTS Site Manager Test Case ID 3.2.9.1 3.2.9.2 3.2.9.3 3.2.9.4 3.2.9.5 3.2.9.6

Test Case Title Configuration of Q1 and fetching Site Information Report (SIR) from remotely connected Flexi EDGE BTS Manager Successful launch of FlexiHub manager from remotely connected Flexi EDGE BTS Manager Successful remote connection to BTS site and fetching of SCF, SIR and Commissioning report Remote BTS Manager access in Read Only mode with different UALC settings Successful connection of 2G Flexi BTS Site Manager via NetAct and display of BTS views Successful execution of TRX test from 2G Flexi BTS Site Manager connected remotely

Runtime diagnostics and BTS alarms Test Case ID 3.2.10.1

Test Case Title Alarm Reporting for Incorrect RF Cabling with ECxx RTC Module

DN086776 Issue 6-0 en

© Nokia Siemens Networks

9 (19)

MENU

3.2.10.2

Alarm Reporting for Incorrect RF Cabling with ERxx DDU Module

RX antenna supervision by comparing RSSI Test Case ID 3.2.11.1

Test Case Title RX antenna supervision by comparing RSSI

TRX Power Down Test Case ID 3.2.12.1 3.2.12.2

Test Case Title Administrative Operations on TRXs in Power Save mode Verification of behavior after Repeated TRX Power down

TRX Test Test Case ID 3.2.13.1 3.2.13.2 3.2.13.3

Test Case Title TRX Test Initiated From 2G Flexi BTS Site Manager In Supervisory state when Ext CCCH is configured at BTS TRX Test Initiated From BSC TRX test in DPTRX 4UD configuration

TX Antenna VSWR Supervision Test Case ID 3.2.14.1 3.2.14.2 3.2.14.3 3.2.14.4 3.2.14.5

Test Case Title Low Power Alarm Handling with Abis Breaks VSWR Alarm Handling for Antenna Hopping Sector VSWR Alarm Handling with Lock/Unlock Operations for TCH antenna with No Ongoing Traffic VSWR Alarm Handling with Lock/Unlock and Block/Unblock Operations for BCCH antenna VSWR Alarm Handling with Lock/Unlock and Block/Unblock Operations for TCH antenna

4.2.3 Value Added Services Remote Interrogation of Serial and Version Numbers Test Case ID 3.3.1.1 3.3.1.2 3.3.1.3

Test Case Title Remote Interrogation of Serial Number and Version Number After Passive Unit Details are Changed Through Append Commissioning Remote Interrogation of Serial Number and Version Number with ECxx RTC module in sector Remote Interrogation of Serial Number and Version Number with ERxx DDU module in sector

Short message cell broadcast without DRX Test Case ID 3.3.2.1

Test Case Title Short message cell broadcast - DRX OFF

Short Message Service Cell Broadcast with DRX Test Case ID 3.3.3.1

Test Case Title Short message cell broadcast - DRX ON

DN086776 Issue 6-0 en

© Nokia Siemens Networks

10 (19)

MENU

4.2.4 Site Solution Packet TRS for UltraSite / BTSplus Test Case ID 3.4.1.1

Test Case Title Software download and activation to Flexi EDGE BTS Site and impact on the legacy BTS site

4.3 Platform Independent BTS Features Functional Test 4.3.1 Base Stations BTS Time Base Reference from PCM Test Case ID 4.1.1.1 4.1.1.2

Test Case Title BTS Time Reference from PCM Time Reference from Abis over IP Ethernet using Adaptive Clock Recovery connection

4.3.2 Base Station Controller Call Release after Loss of TRAU Frame Synchronization Test Case ID 4.2.1.1 4.2.1.2 4.2.1.3

Test Case Title Checking for Call Release after Loss Of TRAU Frame Synchronisation Checking for Call Release after Loss Of TRAU Frame Synchronisation for OSC-DFR (8K TRAU) Checking for Call Release after Loss Of TRAU Frame Synchronisation for the OSC-1 with CSDAP

Ciphering Test Case ID 4.2.2.1 4.2.2.2

Test Case Title Testing A5/0 Algorithm with A5/0 BTS Package Testing A5/0, A5/1 and A5/3 Algorithms with A5/3 BTS Package

Discontinuous Reception (DRX) Test Case ID 4.2.3.1

Test Case Title DRX Behaviour for Combined/Non-combined BCCH

4.3.3 Radio Network Performance BSS Site Synchronization Recovery Improvement Test Case ID 4.3.1.1 4.3.1.2

Test Case Title BCF Recovery after Reset to Slave BCFs in LMU chain with UltraSite and two Flexi BTSs BSS Synchronization Recovery when LMU GPS Signal Lost and Regained after 4 hours

DN086776 Issue 6-0 en

© Nokia Siemens Networks

11 (19)

MENU

Dynamic Frequency Channel Allocation Test Case ID 4.3.2.1 4.3.2.2 4.3.2.3 4.3.2.4

Test Case Title CS Call Support, SMS using Dynamic SDCCH on DFCA Enabled TRX CS and PS Call Support in a DFCA enabled Sector Reconfiguration Support in DFCA and Non DFCA TRX Successful establishment of OSC call (DHR and DFR) on DFCA enabled TRX objects

Dynamic Power Sharing Test Case ID 4.3.3.1 4.3.3.2

Test Case Title Dynamic Power Compression and increase for CS call Dynamic power compression & increase for PS data transfer

Dynamic SDCCH Allocation Test Case ID 4.3.4.1

Test Case Title Call Set-up, SMS using Dynamic SDCCH when Ext CCCH is configured on the BTS

Energy optimized TCH Allocation Test Case ID 4.3.5.1 4.3.5.2

Test Case Title BCCH Power Control BCCH Power Control with Ext-CCCH configured on BTS

Enhanced Automatic Frequency Correction Test Case ID 4.3.6.1

Test Case Title Enhanced Automatic Frequency Correction

FACCH Call Setup Test Case ID 4.3.7.1 4.3.7.2 4.3.7.3 4.3.7.4

Test Case Title DTMF support with AMR/WB Emergency Call Set-Up Through FACCH Emergency Call Set-Up Through FACCH when Ext CCCH configured on the BTS FACCH Call Set Up

General Telecom Aspect Test Case ID 4.3.8.1 4.3.8.2

Test Case Title Successful CS call handover Legacy BTS site to Packet abis Flexi BTS site with TFO enabled Verifying various telecom aspect when end to end call profile is ongoing

Intelligent Frequency Hopping (IFH) Test Case ID 4.3.9.1

Test Case Title Intelligent Frequency Hopping configuration

DN086776 Issue 6-0 en

© Nokia Siemens Networks

12 (19)

MENU

4.3.4 Data High Speed Circuit Switched Data (HSCSD) Test Case ID 4.4.1.1

Test Case Title 9.6 kbits per sec Non-Transparent HSCSD Call

4.3.5 Microcellular MS Speed Detection Test Case ID 4.5.1.1

Test Case Title MS Speed Detection

4.3.6 Transport and Transmission Abis Loop Protection Test Case ID 4.6.1.1

Test Case Title Loop network support test

Abis over IP/Ethernet Test Case ID 4.6.2.1 4.6.2.2 4.6.2.3 4.6.2.4 4.6.2.5

Test Case Title Commissioning a BTS site in PWE mode Configuration of transmission settings of sites in PWE Mode using Remote 2G Flexi BTS Site Manager Fault management for BTS Site in PWE Mode PW recovery after network outage and change of network IP topology Sync recovery from Adaptive Clock Recovery (ACR) in PWE mode

Compressed O&M Abis Signaling Test Case ID 4.6.3.1

Test Case Title Compressed Abis Functionality (OMU SIG on TCH)

FlexiPacket Radio Connectivity Test Case ID 4.6.4.1

Test Case Title Successful Commissioning of Flexi BTS Site when FlexiPacket Radio is connected

Packet Abis Congestion Reaction Test Case ID 4.6.5.1 4.6.5.2 4.6.5.3

Test Case Title Management of BTS traffic during Packet Abis congestion condition (Packet loss on DL Abis congestion) Management of BTS traffic during Packet Abis congestion condition (Abis throughput threshold) Site support equipment data transfer during Packet Abis congestion conditions

DN086776 Issue 6-0 en

© Nokia Siemens Networks

13 (19)

MENU

Packet Abis Security Test Case ID Test Case Title Dynamic changes in diffent plane for Packet Abis security enable/disable(m-plane, u-plane cs, u-plane ps, c-plane, SSE) and its 4.6.6.1 impact on BTS operations like CS , PS calls, SSE traffic O&M operations BCF/BTS lock/unlock, Power reset and resumption 4.6.6.2 of secure traffic on Packet Abis Security enabled planes Packet Abis Security Certificates renewal and reestabishment of 4.6.6.3 Packet Abis Security tunnels with ongoing traffic Successful commissioning of the newly added site with Packet abis security enabled using 2G Flexi BTS Site Manager when CMP is 4.6.6.4 enabled, RefNum, PSK/CA are configured before commissioning Packet Abis ToP and SyncE Test Case ID 4.6.7.1 4.6.7.2 4.6.7.3 4.6.7.4

Test Case Title DAC word stability and stable clock output to tail Legacy BTS site Reporting of alarm with sync loss when SSM is disabled Reporting of alarm with sync loss when SSM is enabled Successful DAC word recovery when it deviates from nominal value

Satellite Abis Test Case ID 4.6.8.1 4.6.8.2 4.6.8.3

Test Case Title Abis Loop Test For Fixed Abis Configuration Successful background SW download during normal operation from BSC Successful fetch of Site Information Report (SIR) from remotely connected 2G Flexi BTS Site Manager

Transmission Fault Management Test Case ID 4.6.9.1

4.6.9.2 4.6.9.3 4.6.9.4 4.6.9.5 4.6.9.6

Test Case Title Blocking CS&PS UDP port from the external firewall during ongoing traffic Recovery of BTS site when link is disconnected between transmission node and BTS site in a mixed loop protection configuration Remote BTS Alarm Handling and Reporting (BTS Polling) Successful recovery of BTS site after Layer-2 break in PAoPSN mode Successful recovery of BTS site after break between transmission node and BTS Recovery of BTS Site when PCM links are removed from BTS Site

Transmission Management Test Case ID 4.6.10.1

Test Case Title Checking the packet loss in abis link using Ethernet OAM Service layer functionality

Transmission Performance Management

DN086776 Issue 6-0 en

© Nokia Siemens Networks

14 (19)

MENU

Test Case ID 4.6.11.1 4.6.11.2 4.6.11.3

Test Case Title Performance data (G.826) collection locally and in BSC Performance data collection (G.826 and Packet abis counters) locally and in BSC Performance data collection (Packet abis counters) locally and in BSC

4.4 Flexi Multiradio BTS Maintenance Functional Test 4.4.1 BTS Module Replacement BTS Unit Replacement Test Case ID 5.1.1.1 5.1.1.2 5.1.1.3 5.1.1.4

Test Case Title Replacement of FSEB Flexi System External Alarm module Replacement of Flexi Multiradio System Module Replacement of the Flexi Multiradio RF Module Replacement of the Flexi Multiradio RF Module (FXxx) in Antenna optimized configuration

Transmission Units replacement Test Case ID 5.1.2.1

Test Case Title BCF Recovery after FIFA Unit replacement

4.5 Flexi EDGE BTS Maintenance Functional Test 4.5.1 BTS Module Replacement BTS Unit Replacement Test Case ID 6.1.1.1 6.1.1.2 6.1.1.3 6.1.1.4 6.1.1.5

Test Case Title Replacement of FSEB Alarm Extension Module Replacement of Flexi EDGE Dual Duplexer Module Replacement of Flexi EDGE Remote Tune Combiner Module Replacement of Flexi EDGE System Extension Module Replacement of Flexi EDGE TRX Module controlling Flexi EDGE Dual Duplexer Module

Transmission Units replacement Test Case ID 6.1.2.1

Test Case Title BCF Recovery after FIxA (E1) Unit replaced with FIxB Unit

4.6 Flexi Multiradio BTS Site Installation validation 4.6.1 BTS Site Expansion Test Case ID 7.1.1

Test Case Title Site expansion by adding another sector through Append

DN086776 Issue 6-0 en

© Nokia Siemens Networks

15 (19)

MENU

7.1.2 7.1.3 7.1.4 7.1.5

commissioning Site expansion by adding new Flexi Multiradio RF Module Site expansion due to HDLC channel addition in Packet Abis over TDM mode in running BTS site TRX expansion to existing sector non-optimised to optimised configuration Successful Site expansion with SCF download from netact

4.6.2 BTS Site Commissioning Test Case ID 7.2.1 7.2.2 7.2.3 7.2.4 7.2.5 7.2.6 7.2.7 7.2.8 7.2.9 7.2.10 7.2.11

Test Case Title Commissioning Partially failed - Cumulative power of TRXs exceeds power capacity of radio branch Commissioning Partially failed - connected HW type is different than the configured one in SCF Commissioning of new Flexi Multiradio BTS Site in Packet Abis over IP/Ethernet mode Commissioning partially Failed when Number of TRX objects exceeds the Flexi Multiradio ESMB System Module capacity Commissioning partially failed - Frequency band mismatch between defined BTS object and physically connected RF module Commissioning partially failed - TRXs frequency is out of radio branch bandwidth Successful Commissioning of BTS site with Dynamic power pooling feature enabled Successful Commissioning with Multi-operator BSS configurations Successful Commissioning - Fresh, Undo, Recommissioining of Flexi Remote Radio Head Successful deletion of a sector through Append commissioning Undo and recommissioning using same SCF

4.6.3 Flexi BTS Autoconnection Test Case ID 7.3.1 7.3.2

Test Case Title Commissioning from netact configuration of working Flexi Multiradio BTS site Re-commissioning of TDM BTS site to Packet Abis over TDM using SCF download from BSC

4.6.4 BTS Site Rehosting Test Case ID 7.4.1 7.4.2

Test Case Title Re-hosting in different BSC with same BCF id (TDM mode) Re-hosting in different BSC with same BCF id in Packet Abis mode

4.7 Flexi EDGE BTS Site Installation validation 4.7.1 BTS Site Expansion Test Case ID 8.1.1

Test Case Title Adding TRXs to Existing Sectors in Packet Abis over IP/Ethernet

DN086776 Issue 6-0 en

© Nokia Siemens Networks

16 (19)

MENU

8.1.2

mode BTS Site Expansion from 4+4+4 Two Way Combining to 6+6+6 Two Way Combining

4.7.2 BTS Site Commissioning Test Case ID 8.2.1 8.2.2 8.2.3 8.2.4 8.2.5 8.2.6 8.2.7

Test Case Title Append commissioning of BTS site for modification of EDAP TS BTS Site Commissioning with mismatch between RF Cabling in SCF and Physical Cabling Commissioning of new BTS site and operator with wrong VLAN tagging Commissioning of new BTS site in Packet Abis over IP/Ethernet mode Commissioning of the BTS site with RFCAD when RX Main cable missing Recommissioning of Abis over IP/Ethernet site to Packet Abis over IP/Ethernet site Recommissioning of TDM (E1) site to Packet Abis over TDM (E1) mode

4.7.3 Flexi BTS Autoconnection Test Case ID 8.3.1 8.3.2

Test Case Title Successful Commissioning from netact configuration of BTS site in abis loop protected configuration Successful Commissioning from netact configuration of new BTS site

4.8 Release Delivery Upgrade Testing 4.8.1 Software Package Creation and Storage Test Case ID 9.1.1 9.1.2 9.1.3 9.1.4

Test Case Title EP Software package creation at BSC EP Software placement at NetAct server Flexi Multiradio Software package creation at BSC Flexi Multiradio Software placement at NetAct server

4.8.2 Software Release Upgrade/Fallback Test Case ID 9.2.1 9.2.2 9.2.3

Test Case Title EX Software Upgrade/Fallback at Startup from BSC EX Software Upgrade/Fallback using NetAct server Flexi Multiradio Software Upgrade/Fallback at Startup from BSC

4.8.3 Installation of 2G Flexi BTS Site Manager Test Case ID 9.3.1 9.3.2

Test Case Title Installation of 2G Flexi BTS Site Manager and Compatibility launcher Installation of 2G Flexi BTS Site Manager (Flexi Multiradio BTS site)

DN086776 Issue 6-0 en

© Nokia Siemens Networks

17 (19)

MENU

and Compatibility launcher

5. REMAINING OPEN FAULTS FOUND IN TESTING List of Generic Faults: LGF-2GBTSf-2011 for Flexi EDGE BTS and LGF-2GBTSmr-2011 for Flexi Multiradio BTS.

6. APPENDICES / REFERENCES [1] Verification Specification for Features DN0979929, Issue 4-0 en

DN086776 Issue 6-0 en

© Nokia Siemens Networks

18 (19)

MENU

Disclaimer The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given “as is” and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document. Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT. This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws. The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright © Nokia Siemens Networks 2011. All rights reserved.