1+1 HSB SD FD Commissioning
January 17, 2017 | Author: Diah Nurani | Category: N/A
Short Description
Download 1+1 HSB SD FD Commissioning...
Description
Security Level:
1+1 HSB-FD-SD Commissioning
www.huawei.com
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
CONTENT • • • •
Basic Knowledge 1+1 HSB 1+1 FD 1+1 SD
Basic Knowledge •
1+1 Configuration For RTN 620, the paired slots (slot5 and slot7) consist a 1+1 protection group; the
paired slots (slot6 and slot8) consist another 1+1 protection group. Slot 5 and slot 6 is main slot respectively. For 1+1 HSB and SD application, It is only necessary to configure main IF board
parameters. For 1+1 FD application, It is necessary to configure main parameters and standby
parameters respectively.
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 3
Basic Knowledge •
Trigger Conditions of the automatic HSB switching Switching Conditions
Description
The hardware of the IF board is faulty. The hardware of the ODU is faulty. POWER_FAIL VOLT_LOS(IF Board) RADIO_TSL_HIGH RADIO_TSL_LOW RADIO_RSL_HIGH
At the same priority.
IF_INPWR_ABN CONFIG_NOSUPPORT R_LOC R_LOF R_LOS MW_LOF The IF connection cable is faulty. HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 4
Basic Knowledge •
Trigger Conditions of the automatic HSM switching Switching Conditions
Description
R_LOC R_LOF
High
R_LOS MW_LOF MW_FECUNCOR
Medium
B1_SD (IDU 620 PDH) B2_SD (IDU 620 SDH )
Low
MW_BER_SD(IDU 605 2B/2F)
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 5
Basic Knowledge •
Hybrid Coupler with Waveguide Interface
Coupler Type
Description
Asymmetrical Hybrid Coupler(6dB)
with one main channel and one standby channel.
Main ODU port insertion loss, dB max:1.8 (38G: 2.0); Standby ODU port insertion loss, dB max: 7.2 (38G:7.4)
Symmetrical Hybrid Coupler (3dB)
with equal attenuation in both channels
ODU port insertion loss, db max:3.8 (38G:4.0).
HUAWEI TECHNOLOGIES CO., LTD.
Application
Huawei Confidential
Receive Power
Page 6
Basic Knowledge •
Trigger Conditions and Antenna Aligning Alarms R_LOF,R_LOS,MW_LOF are the microwave link alarm. While aligning antennas, the microwave link is not stable, will create these alarms. In order to finish antennas aligning quickly, for 1+1 application, we suggest turn off
the standby IF ODU-PWR switch at first, after antenna aligning finishing, turn on the standby IF ODU-PWR.
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 7
Basic Knowledge •
1+1 HSB/FD/SD Compare Item
HSB
FD
SD
Notes
Quantity of ODU
2
2
2
HSB/SD: main ODU type is same as standby.
Quantity of Antenna
1
1/2
2
_
Quantity of Hybrid Coupler
1
1/0
0
_
Quantity of Frequency Channel
1
2
1
HSB/SD: Only configure main IF parameters. FD: Configure main and standby IF parameters respectively.
HSB Support
√
√
√
—
HSM Support
×
√
√
—
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 8
CONTENT • • • •
Basic Knowledge 1+1 HSB 1+1 FD 1+1 SD
1+1 HSB Commissioning •
1+1 HSB Commissioning Steps Link 1+1 Configure
Parameters Configure
Turn off Standby IF ODU-PWR Switch
Turn on Standby IF ODU-PWR Switch
1+1 Switch State and Test
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Align Antenna
Page 10
1+1 HSB Commissioning •
Link 1+1 Configure ③
①
② ④
To Next Page
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 11
1+1 HSB Commissioning •
Link 1+1 Configure
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 12
1+1 HSB Commissioning •
For 1+1 HSB, only configure main IF board parameters.
IP Parameters Configure
③
① ④
②
⑤
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 13
1+1 HSB Commissioning •
Query 1+1 HSB Switch State ①
Switch State ③
②
④
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 14
1+1 HSB Commissioning •
1+1 Switch Control ①
③
②
④
Right Click
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 15
CONTENT • • • •
Basic Knowledge 1+1 HSB 1+1 FD 1+1 SD
1+1 FD Commissioning •
1+1 FD Commissioning Steps Link 1+1 Configure
Parameters Configure
Turn off Standby IF ODU-PWR Switch
Turn on Standby IF ODU-PWR Switch
1+1 Switch State and Test
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Align Antenna
Page 17
1+1 FD Commissioning •
Link 1+1 Configure
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 18
1+1 FD Commissioning •
IF Parameters Configure ③
① ④ ⑤
⑥
⑦
②
⑧
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 19
1+1 FD Commissioning •
IF Parameters Configure
①
③ ④
⑤
⑥
⑦
②
⑧
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 20
CONTENT • • • •
Basic Knowledge 1+1 HSB 1+1 FD 1+1 SD
1+1 SD Commissioning •
1+1 SD Commissioning Steps Link 1+1 Configure
IF Parameters Configure
Turn off Standby IF ODU-PWR Switch
Turn on Standby IF ODU-PWR Switch
Align Standby Antenna
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Align main Antenna
Page 22
1+1 SD Commissioning •
1+1 Link Configure
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 23
1+1 SD Commissioning •
For 1+1 SD, only configure main IF board parameters.
Parameters Configure
③
① ④
②
⑤
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 24
1+1 SD Commissioning
Turn off two side standby ODU's power, turn on two main ODU's power, firstly, align two main antennas.
√: ODU Power on. X: ODU Power off. HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 25
1+1 SD Commissioning
Turn on local site standby ODU's power, keep opposite site main antenna fixed, align local standby antenna towards opposite main one.
√: ODU Power on. X: ODU Power off. HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 26
1+1 SD Commissioning
Turn on opposite standby ODU's power, keep local main antenna fixed, align opposite standby antenna towards local main one.
√: ODU Power on. X: ODU Power off. HUAWEI TECHNOLOGIES CO., LTD.
Huawei Confidential
Page 27
Thank you www.huawei.com
View more...
Comments