07_Eurocodes_Steel_Workshop_WEYNAND.pdf
Short Description
Download 07_Eurocodes_Steel_Workshop_WEYNAND.pdf...
Description
Design of Structural Steel Joints
Dr. Klaus Weynand Feldmann + Weynand GmbH, Aachen, Germany
Prof. Jean-Pierre Jaspart University Univer sity of Liège, Belgium
Design of Structural Steel Joints •
•
Introduction Integration of joints into structural design process
•
Moment resistant joints
•
Simple joints
•
Design tools
Design of Structural Steel Joints • •
Introduction Integration of joints into structural design process
•
Moment resistant joints
•
Simple joints
•
Design tools
Eurocodes Euroco des - Design of steel buildings with worked examples
EN 1993 Part 1.8 Chapter 1 – Introduction Chapter 2 – Basis of design Chapter 3 – Connectio Connections ns made with bolts, rivets or pins Chapter 4 – Welded connections Chapter 5 – Analysis, classification and modelling Chapter 6 – Structural joints connecting H or I sections Chapter 7 – Hollow section joints
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Design of simple joints ECCS Publication No 126 (EN)
• Background information • Design guidelines
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
2 – Basis of design
Brussels, 16 - 17 October 2014
Partial safety coefficien coefficients ts
Eurocodes Euroco des - Design of steel buildings with worked examples
3 – Connections made mechanical fasteners
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
4 – Welded connections
Brussels, 16 - 17 October 2014
Design of Structural Steel Joints •
•
Introduction
Integration of joints into structural structur al design process
•
Moment resistant joints
•
Simple joints
•
Design tools
Eurocodes Euroco des - Design of steel buildings with worked examples
Actual joint response
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Actual joint response
M M Rd S j,ini
cd
Eurocodes Euroco des - Design of steel buildings with worked examples
Influence on the structural response • Displacements • Internal forces • Failure mode and failure load
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Four successive steps for structural integration M
?
?
M
?
Characterization
Classification M
Modelling
Idealization
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Characterization Search for a unified approach whatever the material
M
?
?
?
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Various configurations (1) Continuity
Beam-to-beam
Colum Col umn n ba base sess
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Various configurations (2) Joints in portal frames
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Various configurations (3) Connections and joints in composite construction
Eurocodes Euroco des - Design of steel buildings with worked examples
Various cross-section shapes (1) Hot-rolled and cold-formed
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Various cross-section shapes (2) Built-up profiles
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Various connection elements End plates
Cleats
Splices
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Economy Reduced fabrication, transportation and erection costs
Eurocodes Euroco des - Design of steel buildings with worked examples
Specific design criteria Robustness Joints as key elements
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Characterization Character ization (1) Search for a unified approach
M
?
?
?
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Characterization Character ization (2) Eurocode 3
–
Part 1-8
• Beam-to-beam joints, splices, beam-to-column joints and column bases:
welded connections
bolted connections (anchors for column bases)
Background:
COMPONENT METHOD
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Charact Cha racteriz erization ation (3) - comp compone onent nt method method column web in shear
Three steps
column web in compression
column web in tension
F
F
First step Identification of the active components F
Second step: Response of the components
E k1
M
“Assembly” of the components
E k3
E k2
Third step:
F3,Rd
F2,Rd
F1,Rd
M j ,Rd
M j,Rd
min Fi ,Rd z
S j ,ini S j,ini
cd
E z 2 1 k i
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Charact Cha racteriz erization ation (4) - comp compone onent nt method method EC3 Part 1-8 provides therefore:
• a library of components • rules for the evaluation of the properties of the components (stiffness, resistance, deformation capacity) • rules for the evaluation of the possible component interactions • « as asse semb mbly ly » rule rules s for for comp compon onen ents ts Applicable for simple joint and moment resistant joint
Eurocodes Euroco des - Design of steel buildings with worked examples
Characterization Character ization (4) – Hollow section joints Different approach for lattice girder joints For many types of joint configuration configurations: s:
• Joints considered as a whole • Check of relevant failure modes • Scope of application to be checked
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Four successive steps for structural integration M
?
?
M
?
Characterization
Classification M
Modelling
Idealization
Eurocodes Euroco des - Design of steel buildings with worked examples
Classification (1)
Brussels, 16 - 17 October 2014
M
Rigid Rigid
Stiffness
Semi-rigid Semi-rigid S j,ini Pinned Pinned
Classification Boundaries forboundaries stiffness Initialinitial joint stiffness stiffness Joint
Eurocodes Euroco des - Design of steel buildings with worked examples
Classification (2)
Brussels, 16 - 17 October 2014
M j
Full resistance Full-strength
Resistance
M j,Rd Partial-strength Partial resistance
Pinned Pinned
Boundaries for strength Classification boundaries Joint Jointresistance strength
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Classification (3) Ductility
• Brittle • “Semi-ductile” • Ductile
M j
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Four successive steps for structural integration M
?
?
M
?
Characterization
Classification M
Modelling
Idealization
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Modelling JOINT MODELLING
SIMPLE
SEMICONTINUOUS
CONTINUOUS
BEAM-TO-COLUMN JOINTS MAJOR AXIS BENDING
BEAM SPLICES
COLUMN BASES
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Four successive steps for structural integration M
?
?
M
?
Characterization
Classification M
Modelling
Idealization
Design of Structural Steel Joints •
•
Introduction Integration of joints into structural design process
•
Moment resistant joints
•
Simple joints
•
Design tools
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Example Single sided beam-to-colu beam-to-column mn joint configuration configuration,, bolted end-plate connection 4 M16 8.8 w= 30 80 30 =60
+
+
V
u=10 240
120 60
+ 140
15 M 0 M 1
3
M
PE220
+ 10
EB140 Material: S 235
To be evaluated:
Design moment resistance , initial stiffness
5
1, 0 1, 0
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
General data
Equivalent T-stub in tension Ft
Column hwc hc 2t fc 2rc 140 212 212 92 92mm Avc Ac 2bc t fc twc 2r c 4295, 6 2 14 140 12 12 7 2 12 12 12 1307, 6 mm 2
m
e
w t fc 2
0, 8 rc
bc w 140 80 2
m pl , fc 0, 25
2 t fc2 f yc M 0
80 7 2
0, 812 26, 9mm
30mm
0, 25
122 235 1, 0
8460 Nmm / mm
m l eff
e
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
General data Beam
4 M16 8.8 w= 30 80 30 =60
+
+
u=10 3 240
120 60
z hb u
+
+
IPE220 10 5
140
Lever arm t fb 2
p 220 10
M c ,Rd (classe 1 section)
9,2 9, 2 2
60 165, 4 mm
W pl , yb f yb M 0
15
285. 285.40 406 6 235 235 106 1, 0
67, 07 kNm
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
General data End plate m p
m p2
w t wb 2
0, 8 2aw
80 5,9 2
0, 8 2 3 33, 66mm
m p 2 p u t fb 0, 8 2a f 60 10 9, 2 0, 8 2 5 35,14 mm
e p
b p w 140 80 2
m pl , p 0, 25
2
t p2 f yp M 0
30mm
0, 25
152 235 1, 0
13.218Nmm / mm
m p
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
General data End plate
Alpha factor for effective lengths
1
2
m p m p e p m p 2 m p e p
33,66 33,66 33,66 30 35,14 33,66 33,66 30
0,53
0,55
5,5 5, 5
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
General data Bolts
Ft ,Rd
0,9 0, 9 f ub As Mb
0,9 800 157 10 3 1,25
Fv ,Rd (shear plane in thread)
90,43kN
0,6 0, 6 f ub As Mb
Lb t fc t p 0, 5 hbolt hnut 12 15
1 2
0,6 800 157 10 3 1.25
60,3kN
10 14, 8 2 4 47, 4mm
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Component No 1 – Column web in shear Resistance Vwc,Rd
F Vwp
3 M 0
0,9 1307 1307,6 ,6 235 235 103
3 1, 0
Transformation parameter
M
1 Assumption :
z Vwp
0,9 0, 9 Avc f y ,cw
F Rd ,1
V wc,Rd 159,7
1
159,7 kN
F Stiffness Stiff ness coeff coefficien icientt k1
0,38 Avc h
0,381307 1307,6 ,6 1165,4
3,004mm
159,7 kN
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Component No 2 – Column web in compression Resistance beff ,c ,wc
min t fb 2 a f 2 2t p 5 t fc s ; t fb a f 2 tp u 5 tfc s min 9, 2 2 5 2 2 15 5 12 12 1 2 ; 9, 2 5 2 15 10 1 0 5 12 12 1 2 161, 27 27 mm
Reduction factors to account for compression stresses and instability Assumption : kwc min 1, 0 ; 1, 7 com ,Ed / f y ,wc 1, 0 p 0, 932
1
beff ,c ,wc dc f y ,wc 2
E t wc
0, 932
1 1 1, 3 beff ,c,wc tw c / Avc
2
161,27 92 235 0, 543 0, 673 210 000 7 7
1 11,3 161 161, 27 7 1307 1307,, 6
2
1, 0
0,713
F Rd ,2 kwc beff ,c ,wc twc f y ,wc / M 1 1 0, 0, 71 713 1161, 27 27 7 23510 3 1, 0 18 189,1kN
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Component No 2 – Column web in compression
Stiffness Stiff ness coeff coefficien icientt
k2
0,7 0, 7 beff ,c ,wc t wc hwc
0,7 161 161,27 7 8,589 mm 92
F
Fi ki E i
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Component No 3 – Column web in tension Resistance beff ,t ,wc min 2 m ; 4m 1, 25 25e min 2 26, 9; 9; 4 26, 9 1, 1, 25 25 30 145,10 mm
1
1 1 1, 3 beff ,t ,wc twc / Avc
2
1 1 1,3 145 145,1 ,1 7 1307 1307,, 6
749 145,1 7 23 235 10 F Rd ,3 beff ,t ,wc twc f y ,wc / M 0 0, 74
Stiffness Stiff ness coeff coefficien icientt k3
0,7 0, 7 beff t eff ,t , wc wc wc hwc
0,7 145 145,1 7 92
7,728mm
3
2
0,749
1, 0 17 178, 7 kN
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Component No 4 – Column flange in bending Component No 5 – End plate in bending Equivalent T-stub in tension Ft Ft /4
Ft /4
Ft /4 Ft /4
m
l eff
e
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
T-stub – Effective length Distinction between circular and non-circul non-circular ar yield line patterns
Circular patterns
Non-circular patterns
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
T-stub – Effective length Groups effects to consider in addition to the individual response of each bolt-row
Row 1 Row 2 Row 3
Group 1+2
Group 2+3
Group 1+2+3
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
T-stub – Effective length Groups effects to consider in addition to the individual response of each bolt-row
Row 3
F Rd ,3 min ( FRd ,3,indiv ; F Rd ,3, group )
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Bolt rows considered In this example: only bolt row 1 is considered for tension forces
4 M16 8.8 w= 30 80 30 =60
+
+
60
V
u=10 240
120
+ 140
15
+ 10
3
M
PE220 5
Row 1 Row 2 EB140
Eurocodes Euroco des - Design of steel buildings with worked examples
Component No 4 – Column flange in bending Resistance leff ,t , fc beff ,t ,wc 145 145,1mm
(see (see colu colum mn web web in tens tensio ion) n)
n min e ;1, 25 25 m ; b p w / 2 min 30 ;1, 25 25 26, 9 ; 30 30 mm
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Component No 4 – Column flange in bending
Mode 1 - Com Complet plete e yieldin yielding g of the the flange flange F fc ,Rd ,t 1
4leff ,t , fc mpl , fc m
4 145 145,1 8460 8460 10 3 182, 5kN 26,9
Mode 2 - Bolt failure with yielding yielding of the flange 2 leff ,t , fc mpl , fc 2 Bt ,Rd n 2 145,1 8460 2 90 90,4 10 3 30 F fc ,Rd ,t 2 10 3 26,9 26,9 30 m n
Mode Mo de 3 - Bo Bolt lt fai failu lure re F fc ,Rd ,t 3 2 Bt ,Rd 2 90, 43 180, 9kN
138, 5 kN
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Component No 4 – Column flange in bending Resistance
F Rd ,4 min Ffc ,Rd ,t1 ; Ffc , Rd ,t 2 ; Ffc ,Rd ,t 3 138, 5kN
Stiffness Stiff ness coeff coefficien icientt k4
0,9 0, 9 leff , fc,t t 3fc m3
0,9 145 145,1123 26,93
11,59mm
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Component No 5 – End plate in bending Resistance leff ,t , p mi min 2 m p ; m p min 2 33, 66 ; 5, 5 33, 66 185 mm n p min ep ;1, 25 25m p ; e min 30 ;1 ;1, 25 25 33, 66 66 ;3 ;30 30mm
Mode 1:
Mode 2:
Fep ,Rd ,1
Fep ,Rd ,2
4leff ,t , p m pl , p m p
4 185 185 13.2 13.218 18 33,66
2 leff , p ,t m pl , p 2 Bt , Rd n p m p n p
10 3 291kN
2 18513.218 2 90,43 ,4310 3 30
F Rd ,5 min Fep ,Rd ,1 ; Fep ,Rd ,2 ; Fep ,Rd ,3 162,1kN
33,66 33,66 30
103 162,1kN
Eurocodes Euroco des - Design of steel buildings with worked examples
Component No 5 – End plate in bending
Stiffness Stiff ness coeff coefficien icientt k5
0,9 0, 9 leff ,t , p t 3p m p3
0,9 185 185,0 153 14,73mm 33,66 3
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Component No 7 – Beam flange and web in compression Resistance
F Rd ,7 M c ,Rd / hb t fb
Stiffness Stif fness coeff coefficien icientt k 7
67,07 210,8 210,810
3
318, 2kN
Eurocodes Euroco des - Design of steel buildings with worked examples
Component No 8 – Beam web in tension Resistance beff ,t ,wb leff ,t , p 185 mm F Rd ,8 beff ,t , wb twb f yb / M 0 185 5, 9 235 10 10 3 1, 0 25 256, 5 kN
Stiffness Stiff ness coeff coefficien icientt k 8
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Component No 10 – Bolts in tension Resistance F Rd ,10 2 Bt ,Rd 2 90, 43 180, 9 kN
Mode 3 in T-stubs for component components: s: “column flange in bending” “end plate in bending” •
•
Stiffness coefficient k10 1, 6
A s Lb
1, 6
157 47,4
5, 30mm
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Design moment resistance Relevant component
M j,Rd
F Rd min FRd ,i 138,5kN (Column flange in bending)
Design plastic moment resistance M j , Rd FRd z 138,5 165,4 10
3
,91kNm 22,91
Design elastic moment resistance 2 M j ,el ,Rd M j ,Rd 15,27 kNm 3
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Stiffness Initial stiffness S j ,ini E h / 2
S j,in j,inii
1 k i
i
1 3,00 ,004
2100 210000 00165 165,4 ,4 2 106 1 1 1 1 8,58 ,589
Secant stiffness S j S j ,ini / 2 3117 kNm / rad
7,72 ,728
11,59 ,59
14,73
1 5,30 ,30
6234 kNm / rad
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Design moment-rotation characteristic M M j,Rd j,Rd
S j,ini j,ini
2/3M j,Rd j,Rd
S j
Ersatzsteifigkeit: Secant stiffness
S j = S j,ini / j,ini
Design of Structural Steel Joints •
•
Introduction Integration of joints into structural design process
•
Moment resistant joints
•
Simple joints
•
Design tools
Eurocodes Euroco des - Design of steel buildings with worked examples
Nominally pinned joints
Braced frame
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Nominally pinned joints
V
0
M=0
Eurocodes Euroco des - Design of steel buildings with worked examples
Design of simple joints ECCS Publication No 126 (EN)
• Background information • Design guidelines
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Classification and modelling of joints “Nominally pinned” joints :
M j
S j,ini 0,5EI b /Lb
Partial strength
M j,Rd > 0,25 M full-strength
Nominally pinned
S j,ini = 0
Nominally pinned
M j,Rd = 0
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Classification and modelling of joints Yes, …under the reservation the joint has:
• a sufficient rotation capacity = capacity to “rotate” • a sufficient ductility = capacity to follow the actual loading path in a ductile way
M MRd
Yielding Yielding criterion Actual loading path Supposed loading path VRd
V
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Supplementary design requirement Sufficient resistance to «catenary effects» so as to provide required structural robustness
Eurocodes Euroco des - Design of steel buildings with worked examples
Example: Partial depth end-plate Components
• • • • • • • • •
Bolts in shear End-plate in bearing End-plate in shear (gross section) End-plate in shear (net section) End-plate in shear block End-plate in bending Beam web in shear Welds in shear Column flange in bearing
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Partial depth end-plate Strength requirement
• Use of “component method” for the assessment of VRd
Assessment of the streng strength th of all the constitutive components of the joint + “Assembly” of these components
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Partial depth end-plate Rotation capacity requireme requirement nt Bending moment
Bolts in tension
Bending moment
Contact between supported beam and supporting element
Compression force
avail
Rotation
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Partial depth end-plate Rotation capacity requirement requireme nt avail
d b hb
h p
h p d b avail
he
t p
t p he
Eurocodes Euroco des - Design of steel buildings with worked examples
Partial depth end-plate Ductility requirement
• Prevent premature fracture of the bolts • Prevent premature fracture of the welds
under unavoidable bending moment in the joint
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Brussels, 16 - 17 October 2014
Partial depth end-plate Ductility requirements • Prevent premature collapse of the bolts d t p d t p
2,8 2, 8
2,8 2, 8
f yp f ub f ycf f ub
for the end-plate
for the supporting column d and f ub : diameter and tensile strength of bolts
Yielding of end-plate prior to tensile fracture of bolts
Design of Structural Steel Joints •
•
Introduction Integration of joints into structural design process
•
Moment resistant joints
•
Simple joints
•
Design tools
Eurocodes Euroco des - Design of steel buildings with worked examples
Practical design tools • Tables of standardized joints
• Dedicated software
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Worked Example
Brussels, 16 - 17 October 2014
Configuration Beam IPE 500 Column HEA 340 End plate connection Design assumption Rigid joint Frame analysis MEd = 220 kNm
CoP software used for this example: example: http://cop. http://cop.fw-ing.com fw-ing.com
Eurocodes Euroco des - Design of steel buildings with worked examples
Design resistance: Classification: Failure mode:
kNm < 220 220 kNm MRd = 196 kNm Semi-rigid Column web in compression
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Failure mode: End plate in bending
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Failure mode: Column web panel in shear
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Failure mode: Column web panel in shear
Brussels, 16 - 17 October 2014
Eurocodes Euroco des - Design of steel buildings with worked examples
Failure mode: Column web panel in shear
Brussels, 16 - 17 October 2014
Design of Structural Steel Joints
Dr. Klaus Weynand Feldmann + Weynand GmbH, Aachen, Germany
Prof. Jean-Pierre Jaspart University Univer sity of Liège, Belgium
View more...