04 D01 Communication Modules V1.0 en-US
Short Description
digsi 5-siemens...
Description
SIPROTEC 5 / DIGSI 5 Basic Course 04 Communication modules www.siemens.com/poweracademy
Copyright © Siemens AG 2012. All rights re served.
Content
Content
Plugin – modules hardware and general features Initial communication configuration
Assignment for protocols
Protocol features - Overview
Protocol testing
04 Communication modules
C o p y r i g h t © S i e m e n s A G 2 0 1 2 . A l l r i g h t s r e s e r v e d .
Siemens Power Academy TD
Front view of the device with USB interfaces
USB interface for PC with DIGSI 5
Standard USB cable (no special cable required) No USB hub supported Initialize device via USB interface necessary for the initial configuration
USB interface for a memory stick
Allow connection of a memory stick Future features possible like: Read out file system, logs and fault records Authorize with a memory stick (user authorization) Device replacement. Device configuration stored on the memory stick.
04 Communication modules
C o p y r i g h t © S i e m e n s A G 2 0 1 2 . A l l r i g h t s r e s e r v e d .
Siemens Power Academy TD
Rear view of the device with terminals, plug-in-module positions and communication ports (1)
Plug-in module (Position E) Can be equipped with every available plug in-module Modules can be changed without opening the device Different electrical or optical modules available for serial or Ethernet based protocols and applications
Plug-in module (Position F) Can be equipped with every available plug-in-module Modules can be changed without opening the device Different electrical or optical modules available for serial or Ethernet based protocols and applications
E Integrated Ethernet interface (Port J) F
J
Rear standard Ethernet interface for DIGSI 5 Option: Cost effective IEC 61850 client server communication (for six clients, no GOOSE messages)
C o p y r i g h t © S i e m e n s A G 2 0 1 2 . A l l r i g h t s r e s e r v e d .
04 Communication modules
Siemens Power Academy TD
Rear view of the device with terminals, plug-in-module positions and communication ports (2)
Time synchronization port (Port G) Time telegrams IRIB-B00 from GPS – receiver Time telegrams from a DFC 77 receiver 1 s pulse for high precision time sync. applications Fully pin compatible with SIPROTEC 4 Port A (all external converters and cables can be used)
Separate/remote operational panel (Port H)
G
Connection to remote operational panel External panel will be fully supplied by this port
H Com-Link to expansion module (Port K) J K
Communication link to expansion module CB202 Special Ethernet link (can not be used as standard Ethernet connection) CB202 can not be used stand alone
C o p y r i g h t © S i e m e n s A G 2 0 1 2 . A l l r i g h t s r e s e r v e d .
04 Communication modules
Siemens Power Academy TD
Rear view of expansion – module CB202 for 3 additional plug-in – module
Terminal block For independent wide range power supply
Com-Link to base module (Port L)
Communication link to Port K of base module
L
M
Plug-in module (Position M) Can be equipped with special plug-in-modules (20 mA analog inputs) Not designed for use with communication modules
Plug-in module (Position N) Can be equipped with every available plug-in-module Modules can be changed without opening the device Different electrical or optical modules available for serial or Ethernet based protocols and applications
N
Plug-in module (Position P) P
C o p y r i g h t © S i e m e n s A G 2 0 1 2 . A l l r i g h t s r e s e r v e d .
Can be equipped with every available plug-in-module Modules can be changed without opening the device Different electrical or optical modules available for serial or Ethernet based protocols and applications
04 Communication modules
Siemens Power Academy TD
A trend-setting communication architecture A new communication design
Hardware and communication design is like playing with LEGO bricks
Building new functions through use of programmable FPGA 1) hardware (HDLC controller, time tagging, MAC address filtering for GOOSE…). Microprocessors is running inside the FPGA Different applications running on one module type (Serial protocols and protection data interface on one type of module) Separation of communication (plug-in module) and protection / control application (main CPU)
C o p y r i g h t © S i e m e n s A G 2 0 1 2 . A l l r i g h t s r e s e r v e d .
from easy one to complex functions
1) Field programmable gate array
04 Communication modules
Siemens Power Academy TD
Communication plug-in modules A common architecture is used for all modules
Ethernet module without / with integrated switch
r o t c e n n o c s u b l a n r e t n I
Universal serial module with 2 optical ports
d n e t n o r f l a c i s y h P
r r o o t t s c c k e e n i n n l n n t o o e c c n r s s e u u h b b t l l E a a n h n r t i r e e w t t n n I I
04 Communication modules
d d n n e t e t n n o r o f r l f l a c a i c s i y s y h h P P
C o p y r i g h t © S i e m e n s A G 2 0 1 2 . A l l r i g h t s r e s e r v e d .
Siemens Power Academy TD
Serial electrical and optical communication module with one or two independent ports
One or two RS485 ports with RJ45 – connectors for one / two independent protocol applications Use of standard Ethernet patch cables saves cost for cabling (no 7XV5103 cables required) Each module has a unique readable name (e.g. USART-AB-1EL, USART-AC-2EL)
Electrical module with RS485 interface
One or two 820 nm fiber optical ports with ST – connectors for one / two independent protocol applications Optical connector and cabling fully compatible to SIPROTEC 4. Multimode-fiber 62,5/125 μm Each module has a unique readable name
C o p y r i g h t © S i e m e n s A G 2 0 1 2 . A l l r i g h t s r e s e r v e d .
(e.g. USART-AD-1FO, USART-AE-2FO) Fiber optical module with 820 nm interface
Synchronous (HDLC or IEEE C37.94) or asynchronous operation mode
04 Communication modules
Siemens Power Academy TD
Optical long distance communication modules with one or two independent ports
One or two 1300 / 1550 nm ports with LC – simplex or LC – duplex connectors for one/two independent protocol applications Spanned distance over single mode fiber 24 km / 60 km / 100 km with 2 fibers 40 km over 1 fiber (integrated WDM*) Saves expensive fibers for long distances Spanned distance over multimode fiber 4 km with 2 fiber cables Identical hardware like 24 km single mode module Each module has a unique readable name
Optical long distance module with two 1300 or 1550 nm interfaces
C o p y r i g h t © S i e m e n s A G 2 0 1 2 . A l l r i g h t s r e s e r v e d .
(e.g. USART-AF-1LDFO, USART-AW-2LDFO)
* Wave division multiplexer 04 Communication modules
Siemens Power Academy TD
Optical or electrical Ethernet module Two ports without or with integrated switch Spanned distance over electrical Ethernet
Two RJ45 connectors 20 m with CAT5 double shielded cables
Spanned distance over optical Ethernet
2 LC-duplex connectors 2 km with 50/125 um or 62,5/125 um fiber cables
Operation without or with the integrated switch for the optical and electrical Ethernet module
Electrical Ethernet module with two electrical ports
One or two ports connected to an external switch. Active port and hot standby port if one connection fails (as SIPROTEC 4 EN100) Operation with integrated switch. RSTP for max. 40 devices in a Ethernet ring topology. This mode is available for every Ethernet based application (e.g. IEC 61850, DNP 3, syncrophasor protocol ...... )
C o p y r i g h t © S i e m e n s A G 2 0 1 2 . A l l r i g h t s r e s e r v e d .
Each module has a unique readable name
Optical Ethernet module with two optical ports
(e.g. ETH-BA-2EL, ETH-BB-2FO)
04 Communication modules
Siemens Power Academy TD
General features of the communication in SIPROTEC 5 devices
Two module positions in the base housing (E / F). Another three module positions on CB202 extension for communication (M,N,P) Customer orders plug-in – modules which are not preconfigured with a protocol or communication - application. Protocols or applications running on plug-in – modules are assigned to the specific module and it's port with DIGSI 5 during the initial configuration process. Two serial communication applications running on one module offer a high application
density (e.g. IEC 60870-5-103 and protection data interface on one USART-AE –2FO module). Communication redundancy (+ time sync.)
Hardware redundancy (e.g. two substation control interfaces pluggable, two ports) Optical or electrical ring configuration (no interruption of the ring when CB202 is supplied from another battery as the main device) Functional redundancy (e.g. redundant protocols with 2*IEC 60870-5-103)
04 Communication modules
C o p y r i g h t © S i e m e n s A G 2 0 1 2 . A l l r i g h t s r e s e r v e d .
Siemens Power Academy TD
Content
Content
Plugin – modules hardware and general features Initial communication configuration
Assignment for protocols
Protocol features - Overview
Protocol testing
04 Communication modules
C o p y r i g h t © S i e m e n s A G 2 0 1 2 . A l l r i g h t s r e s e r v e d .
Siemens Power Academy TD
Which protocol applications are running on which module?
Protocols running on serial modules:
C o p y r i g h t © S i e m e n s A G 2 0 1 2 . A l l r i g h t s r e s e r v e d .
IEC 60870-5-103, DNP 3, PI (Protection Interface)
Protocols running on Ethernet modules:
IEC 61850 (C/S 1) , GOOSE), DNP 3, IEEE C37.118, SNTP, RSTP, DCP, DIGSI 5
1) Clients Server
04 Communication modules
Siemens Power Academy TD
View more...
Comments