01-03 Configuring Ethernet Services

Share Embed Donate


Short Description

Download 01-03 Configuring Ethernet Services...

Description

OptiX OSN 3500/2500/1500 Configuration Guide

Contents

Contents 3 Configuring Ethernet Services ................................................................................................3-1 3.1 Configuring the Point-to-Point EPL Service .................................................................................................3-2 3.1.1 Engineering Requirements...................................................................................................................3-2 3.1.2 Engineering Planning...........................................................................................................................3-2 3.1.3 Configuration Process(by Station) .......................................................................................................3-6 3.1.4 Configuration Process (by Trail)........................................................................................................3-15 3.2 Configuring the PORT Shared EPL Service................................................................................................3-18 3.2.1 Engineering Requirements.................................................................................................................3-18 3.2.2 Engineering Planning.........................................................................................................................3-18 3.2.3 Configuration Process(by Station) .....................................................................................................3-21 3.2.4 Configuration Process (by Trail)........................................................................................................3-26 3.3 Configuring the VCTRUNK Shared EPL Service ......................................................................................3-29 3.3.1 Engineering Requirements.................................................................................................................3-29 3.3.2 Engineering Planning.........................................................................................................................3-30 3.3.3 Configuration Process(by Station) .....................................................................................................3-33 3.3.4 Configuration Process (by Trail)........................................................................................................3-38 3.4 Configuring the EPLn Service ....................................................................................................................3-42 3.4.1 Engineering Requirements.................................................................................................................3-42 3.4.2 Engineering Planning.........................................................................................................................3-42 3.4.3 Configuration Process(by Station) .....................................................................................................3-45 3.4.4 Configuration Process (by Trail)........................................................................................................3-54

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

i

OptiX OSN 3500/2500/1500 Configuration Guide

Figures

Figures Figure 3-1 Ethernet service networking and port allocation...............................................................................3-3 Figure 3-2 Board layout of NE1.........................................................................................................................3-3 Figure 3-3 Board layout of NE5.........................................................................................................................3-4 Figure 3-4 Service configuration diagram..........................................................................................................3-4 Figure 3-5 SDH timeslot allocation for Ethernet services..................................................................................3-6 Figure 3-6 Ethernet service networking and port allocation.............................................................................3-19 Figure 3-7 Service configuration diagram........................................................................................................3-19 Figure 3-8 Timeslot allocation diagram............................................................................................................3-21 Figure 3-9 Ethernet service networking and port allocation.............................................................................3-30 Figure 3-10 Board layout of NE2 and NE3......................................................................................................3-31 Figure 3-11 Service configuration diagram ......................................................................................................3-31 Figure 3-12 SDH timeslot allocation for Ethernet services..............................................................................3-32 Figure 3-13 Ethernet service networking and port allocation...........................................................................3-42 Figure 3-14 Board layout of NE2 and NE3......................................................................................................3-43 Figure 3-15 Board layout of NE4.....................................................................................................................3-43 Figure 3-16 Service configuration diagram......................................................................................................3-44 Figure 3-17 SDH timeslot allocation for Ethernet services..............................................................................3-45

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

iii

OptiX OSN 3500/2500/1500 Configuration Guide

Tables

Tables Table 3-1 Mapping between Ethernet boards and Ethernet services ..................................................................3-1 Table 3-2 Service requirement of each station....................................................................................................3-2 Table 3-3 Ethernet service connection table .......................................................................................................3-5 Table 3-4 Process of point-to-point EPL service configuration ..........................................................................3-6 Table 3-5 Process of creating point-to-point EPL service (by trail)..................................................................3-15 Table 3-6 Ethernet service connection table .....................................................................................................3-20 Table 3-7 Process of PORT shared EPL service configuration.........................................................................3-21 Table 3-8 Process of creating PORT-shared EPL service (by trail) ..................................................................3-26 Table 3-9 Ethernet service connection table .....................................................................................................3-32 Table 3-10 Process of VCTRUNK shared EPL service configuration..............................................................3-33 Table 3-11 Process of creating VCTRUNK-shared EPL service (by trail) .......................................................3-39 Table 3-12 Ethernet service connection table ...................................................................................................3-44 Table 3-13 Forwarding filter table ....................................................................................................................3-45 Table 3-14 Process of EPLn service configuration...........................................................................................3-46 Table 3-15 Process of creating EPLn service (by trail).....................................................................................3-54

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

v

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

3

Configuring Ethernet Services

About This Chapter This chapter describes the process of configuring Ethernet private line (EPL) and Ethernet private local area network (EPLn) services on the T2000, and related engineering requirements and engineering information as well. The configuration of Ethernet virtual private line (EVPL) and Ethernet virtual private local area network (EVPLn) will be described with resilient packet ring (RPR) in Chapter 4. Through this example, you can learn how to configure EPL and other similar services. The following table is a mapping table which associates the Ethernet services to the Ethernet boards of the OptiX OSN 3500/2500/1500. Table 3-1 Mapping between Ethernet boards and Ethernet services Ethernet ser vices

EPL

EVPL

EPLn

EVPLn

EFT8

Supported

Not supported

Not supported

Not supported

EFT4

Supported

Not supported

Not supported

Not supported

EGT2

Supported

Not supported

Not supported

Not supported

EFS4

Supported

Supported

Supported

Supported

EFS0

Supported

Supported

Supported

Supported

EGS2

Supported

Supported

Supported

Supported

Board

In this chapter, the OptiX OSN 3500 product is taken as an example. For the OptiX OSN 2500 and the OptiX OSN 1500A/B, service configuration is performed in the same way. The only difference is that the boards of the OptiX OSN 2500 and the OptiX OSN 1500A/B are inserted in different slots.

The following table lists the contents of this chapter.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-1

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Title

Description

3.1 Configuring the Point-to-Point EPL Service

Describes how to configure the point-to-point EPL services on the T2000

3.2 Configuring the PORT Shared EPL Service

Describes how to configure the port shared EPL services on the T2000

3.3 Configuring the VCTRUNK Shared EPL Service

Describes how to configure the VCTRUNK shared EPL services on the T2000

3.4 Configuring the EPLn Service

Describes how to configure the EPLn services on the T2000

3.1 Configuring the Point-to-Point EPL Service 3.1.1 Engineering Requirements The two companies A and B in NE1 need to transmit data services to NE5 through multi-service transport platform (MSTP) equipment. The services of A and B are required to be completely isolated. Both A and B provide 100 Mbit/s Ethernet electrical interfaces. A requires 10 Mbit/s bandwidth, B requires 40 Mbit/s bandwidth, and their interconnected equipment does not support VLAN, as shown in Table 3-2. Table 3-2 Service requirement of each station User

Service requirement

Source station (number of ports occupied)

Sink station (number of ports occupied)

Bandwidth

A

Point-to-point

NE1 (1)

NE5 (1)

10 Mbit/s

B

Point-to-point

NE1 (1)

NE5 (1)

40 Mbit/s

3.1.2 Engineering Planning The engineering design department conducts planning based on the above requirements and the engineering information described in Chapter 1, and outputs the following engineering information: z

Networking Diagram

z

Board Information of Each NE

z

Service Configuration Diagram of Each NE

z

Timeslot Allocation Diagram

Networking Diagram Figure 3-1 shows the Ethernet service networking and port allocation.

3-2

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Figure 3-1 Ethernet service networking and port allocation B

A PORT1

PORT2

T2000 STM-4 two-fiber bidirectional nonprotection chain

NE1 STM-16 two-fiber bidirectional MSP ring

NE2

NE5

NE4 PORT1

PORT2

NE3 A

B

VC-Trunk

Board Information of Each NE Ethernet boards need to be added according to the added service type and traffic volume. NE1 and NE5 are added with one N1EFS4 board respectively. Other NEs remain unchanged. Figure 3-2 and Figure 3-3 show the board layout of NE1 and NE5 respectively. Figure 3-2 Board layout of NE1

S 1 0

FAN

GSCC GSCC

S S S S S S S S 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8

SL16 N1EFS4

GXCSA

SL16

PQ1

PQ1

S S S S S S S S S 1 2 3 4 5 6 7 8 9

PQ1 PQ1

AUX

PIU FAN

GXCSA

FAN

Issue 01 (2006-09-20)

S S S S S S S S S 2 3 3 3 3 3 3 3 3 9 0 1 2 3 4 5 6 7

S 2 8

PIU

D75S D75S D75S D75S D75S D75S

S S S S S S S S S 1 2 2 2 2 2 2 2 2 9 0 1 2 3 4 5 6 7

Huawei Technologies Proprietary

3-3

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Figure 3-3 Board layout of NE5 S 2 8

AUX

C34S

FAN

PL3

GSCC GSCC

S S S S S S S S 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8

S 1 0

N1EFS4

SL4

GXCSA

S S S S S S S S S 1 2 3 4 5 6 7 8 9

FAN

GXCSA

FAN

PQ1

S S S S S S S S S 2 3 3 3 3 3 3 3 3 9 0 1 2 3 4 5 6 7

PIU

PIU

D75S D75S

S S S S S S S S S 1 2 2 2 2 2 2 2 2 9 0 1 2 3 4 5 6 7

Service Configuration Diagram of Each NE Figure 3-4shows the service configuration diagram of NE1 and NE5. Figure 3-4 Service configuration diagram

PORT

A

VCTRUNK

PORT1

PORT1

10M

SDH

VCTRUNK1 VC4-4:VC12-1~VC12-5

B

PORT

VCTRUNK

PORT2

10M

VCTRUNK1 VC4-4:VC12-1~VC12-5

PORT2

40M

A

VCTRUNK2

VCTRUNK2

VC4-1:VC-3-1

VC4-1:VC-3-1

NE1

B

40M

NE5

Only VC4-4 can be used when the N2EFS0 and N1EFS4 boards are bounded with a path at VC-12 level.

Table 3-3 shows the Ethernet service connection table.

3-4

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Table 3-3 Ethernet service connection table Service

A

B

Source NE

NE1

NE1

Source board - port

13-N1EFS4-1

13-N1EFS4-2

Source Timeslot range

VC4-4: VC12-1–VC12-5

VC4-1: VC3-1

Source VCTRUNK

VCTRUNK1

VCTRUNK2

Working mode of source PORT

Auto negotiation

Auto negotiation

TAG flag of source PORT

Access

Access

VLAN ID of source PORT

1

2

Bound bandwidth

5 x VC-12

1 x VC-3

Sink NE

NE5

NE5

Sink board - port

15-N1EFS4-1

15-N1EFS4-2

Sink Timeslot range

VC4-4: VC12-1–VC12-5

VC4-1: VC3-1

Sink VCTRUNK

VCTRUNK1

VCTRUNK2

Working mode of sink PORT

Auto negotiation

Auto negotiation

TAG flag of sink PORT

Access

Access

VLAN ID of sink PORT

1

2

Attribute

Timeslot Allocation Diagram Figure 3-5shows the SDH timeslot allocation.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-5

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Figure 3-5 SDH timeslot allocation for Ethernet services Ring Station NE1 12-SL16-1

Timeslot

NE4 NE3 NE2 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1

NE1 7-SL16-1

VC-12: 1-5 VC4-3

13-EFS4: VC4-4 VC-3: 1

VC4-4

13-EFS4: VC4-1

Chain Station NE4 13-SL4-1

Timeslot

NE5 7-SL4-1

VC-12: 1-5 VC4-3

15-EFS4: VC4-4 VC-3: 1

VC4-4

15-EFS4: VC4-1 Forward Add/Drop

3.1.3 Configuration Process(by Station) Table 3-4 shows the process of configuring the point-to-point EPL service on the T2000. Table 3-4 Process of point-to-point EPL service configuration Procedure

Description

Remarks

1

Creating a board

2

Configuring Ethernet interfaces

3

Configuring bound paths

4

Creating the point-to-point EPL service

5

Configuring committed access rate (CAR)

6

Configuring the cross-connect from Ethernet boards to SDH line boards

Optional

Creating a Board Follow the steps below to create a board. Step 1 In the Main Topology, double click the NE1 icon to open the NE panel. Step 2 Right click slot 13 according to the board layout shown in Figure 3-2, and select N1EFS4 from the shortcut menu. Step 3 Make sure that the N1EFS4 board has been configured in slot 13 and click

3-6

Huawei Technologies Proprietary

.

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Step 4 Repeat steps 1–3 to create the Ethernet board of NE5. Figure 3-3 shows the board layout of NE5. ----End

Configuring NE1 Data See the T2000 online help for the meaning of each parameter during service configuration.

Step 1 Configuring Ethernet interfaces 1.

Right click the NE1 icon in the Main Topology, and select NE Explorer.

2.

Select 13-N1EFS4 from the Object Tree and Configuration > Ethernet Interface . Management > Ethernet Interface from the Function Tree, and then click

3.

Select External Port, and set as follows. Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 and PORT2 to Enabled. Click Apply.

4.

Select the Tag Attribute tab. Set the TAG of the PORT1 and PORT2 to Access. Other items adopt the default value. Click Apply.

Step 2 Configuring bound paths 1.

Select the Bound Path tab from the Internal Port page.

2.

Click Configuration. Then, the Bound Path Configuration dialog box is displayed.

3.

To set bound paths for VCTRUNK1, set as follows in the dialog box.

Issue 01 (2006-09-20)



Configurable Ports: VCTRUNK1



Level: VC12-xv



Direction: Bidirectional



Available Resources: VC4-4



Select VC12-1 to VC12-5 from the Available Timeslots one by one, and then click .

Huawei Technologies Proprietary

3-7

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

4.

To set a bound path for VCTRUNK2, set as follows in the dialog box. −

Configurable Ports: VCTRUNK2



Level: VC3-xv



Direction: Bidirectional



Available Resources: VC4-1



Select VC3-1 from the Available Timeslots, and then click



Click OK.

.

Step 3 Creating the point-to-point EPL service

3-8

1.

Select 13-N1EFS4 from the Object Tree and select Configuration > Ethernet Service > Ethernet Line Service from the Function Tree.

2.

Click New, and the Create Ethernet Line Service dialog box is displayed.

3.

According to Figure 3-4, set as follows to create the EPL service for A. −

Service Type: EPL



Service Direction: Bidirectional



Source Port: PORT1



Sink Port: VCTRUNK1



Click Apply.

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

4.

3 Configuring Ethernet Services

Repeat 3 to create the EPL service for B. Set as follows in the dialog box. −

Service Type: EPL



Service Direction: Bidirectional



Source Port: PORT2



Sink Port: VCTRUNK2



Click OK.

Step 4 Configuring CAR (optional) 1.

Select 13-N1EFS4 from the Object Tree and select Configuration > QoS Management > Flow Management from the Function Tree, and then the CAR tab.

2.

Click New, and the Create CAR dialog box is displayed.

3.

Set as follows in the dialog box.

Issue 01 (2006-09-20)



CAR ID: 1



Enabled/Disabled: Enabled



Committed Information Rate(kbit/s): 10 Mbit/s



Committed Burst Size(kbyte): 0



Peak Information Rate(kbit/s): 20 Mbit/s

Huawei Technologies Proprietary

3-9

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

4.



Maximum Burst Size(kbyte): 0



Click Apply.

Repeat 3 to set as follows in the dialog box: −

CAR ID: 2



Enabled/Disabled: Enabled



Committed Information Rate(kbit/s): 40 Mbit/s



Committed Burst Size(kbyte): 0



Peak Information Rate(kbit/s): 50 Mbit/s



Maximum Burst Size(kbyte): 0



Click OK.

5.

Select the Flow tab.

6.

Set as follows in the dialog box for PORT1 and VCTRUNK1.

7.



Bound CAR: 1



Click Apply.

Repeat 6 to set the bound CAR for port 2 and VCTRUNK2. −

Bound CAR: 2



Click Apply.

Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards

3-10

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

1.

Select NE1 from the Object Tree.

2.

Select Configuration > SDH Service Configuration from the Function Tree.

3.

Click Create, and the Create SDH Service dialog box is displayed.

4.

Set as follows in the dialog box.

5.

Issue 01 (2006-09-20)



Level: VC12



Direction: Bidirectional



Source Slot: 13-N1EFS4-1(SDH-1)



Source VC4: VC4-4



Source Timeslot Range(e.g.1,3-6): 1–5



Sink Slot: 7-N2SL16-1(SDH-1)



Sink VC4: VC4-3



Sink Timeslot Range(e.g.1,3-6): 1–5



Activate Immediately: Yes



Click Apply.

Repeat 4 to set as follows in the dialog box. −

Level: VC3



Direction: Bidirectional



Source Slot: 13-N1EFS4-1(SDH-1)

Huawei Technologies Proprietary

3-11

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services −

Source VC4: VC4-1



Source Timeslot Range(e.g.1,3-6): 1



Sink Slot: 7-N2SL16-1(SDH-1)



Sink VC4: VC4-4



Sink Timeslot Range(e.g.1,3-6): 1



Activate Immediately: Yes



Click Apply.

----End

Configuring NE5 Data The data configuration of NE5 is the same as that of NE1, except that some parameters are different.

Step 1 Configuring Ethernet interfaces 1.

Click the NE switching shortcut icon

2.

Select 15-N1EFS4 from the Object Tree and select Configuration > Ethernet Interface Management > Ethernet Interface from the Function Tree. Then, click .

3.

Select External Port, and set as follows.

. Select NE5, and click OK.



Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 and PORT2 to Enabled. Click Apply.



Select the TAG Attribute tab. Set the TAG of the PORT1 and PORT2 to Access.



Other items adopt the default value. Click Apply.

Step 2 Configuring bound paths 1.

Select the Bound Path tab from the Internal Port page.

2.

Click Configuration, and the Bound Path Configuration dialog box is displayed.

3.

To set bound paths for VCTRUNK1, set as follows in the dialog box.

4.



Configurable Ports: VCTRUNK1



Level: VC12-xv



Direction: Bidirectional



Available Resources: VC4-4



Select VC12-1 to VC12-5 from the Available Timeslots one by one, and then click .

To set a bound path for VCTRUNK2, set as follows in the dialog box. −

Configurable Ports: VCTRUNK2



Level: VC3-xv



Direction: Bidirectional



Available Resources: VC4-1



Select VC3-1 from the Available Timeslots, and then click



Click OK.

.

Step 3 Creating the point-to-point EPL service

3-12

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

1.

Select Configuration > Ethernet Service > Ethernet Line Service from the Function Tree.

2.

Click New and the Create Ethernet Line Service dialog box is displayed.

3.

According to Figure 3-4 set as follows to create the EPL service for A.

4.



Service Type: EPL



Service Direction: Bidirectional



Source Port: PORT1



Sink Port: VCTRUNK1



Click Apply.

Repeat 3 to create the EPL service for B. Set as follows in the dialog box. −

Service Type: EPL



Service Direction: Bidirectional



Source Port: PORT2



Sink Port: VCTRUNK2



Click OK.

Step 4 Configuring CAR (optional) 1.

Select Configuration > QoS Management > Flow Management from the Function Tree and select the CAR tab.

2.

Click New and the Create CAR dialog box is displayed.

3.

Set as follows in the dialog box.

4.



CAR ID: 1



Enabled/Disabled: Enabled



Committed Information Rate(kbit/s): 10 Mbit/s



Committed Burst Size(kbyte): 0



Peak Information Rate(kbit/s): 20 Mbit/s



Maximum Burst Size(kbyte): 0



Click Apply.

Repeat 3 to set as follows in the dialog box. −

CAR ID: 2



Enabled/Disabled: Enabled



Committed Information Rate(kbit/s): 40 Mbit/s



Committed Burst Size(kbyte): 0



Peak Information Rate(kbit/s): 50 Mbit/s



Maximum Burst Size(kbyte): 0



Click OK.

5.

Select the Flow tab.

6.

Set the bound CAR for PORT1 and VCTRUNK1.

7.

Issue 01 (2006-09-20)



Bound CAR: 1



Click Apply.

Repeat 6 to set the bound CAR for PORT 2 and VCTRUNK2. −

Bound CAR: 2



Click Apply.

Huawei Technologies Proprietary

3-13

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards 1.

Select NE5 from the Object Tree.

2.

Select Configuration > SDH Service Configuration from the Function Tree.

3.

Click Create, and the Create SDH Service dialog box is displayed.

4.

Set as follows in the dialog box.

5.



Level: VC12



Direction: Bidirectional



Source Slot: 15-N1EFS4-1(SDH-1)



Source VC4: VC4-4



Source Timeslot Range(e.g.1,3-6): 1–5



Sink Slot: 7-N2SL4-1(SDH-1)



Sink VC4: VC4-3



Sink Timeslot Range(e.g.1,3-6): 1–5



Activate Immediately: Yes



Click Apply.

Repeat 4 to set as follows in the dialog box. −

Level: VC3



Direction: Bidirectional



Source Slot: 15-N1EFS4-1(SDH-1)



Source VC4: VC4-1



Source Timeslot Range(e.g.1,3-6): 1



Sink Slot: 7-N2SL4-1(SDH-1)



Sink VC4: VC4-4



Sink Timeslot Range(e.g.1,3-6): 1



Activate Immediately: Yes



Click Apply.

----End

Configuring NE4 Data The Ethernet service of NE4 to be configured is pass-through service. Follow the steps below to configure NE4 data. Step 1 Click the NE switching shortcut icon

. Select NE4, and click OK.

Step 2 Select Configuration > SDH Service Configuration from the Function Tree. Step 3 Click Create, and the Create SDH Service dialog box is displayed. Step 4 Set as follows in the dialog box.

3-14

z

Level: VC12

z

Direction: Bidirectional

z

Source Slot: 12-N2SL16-1(SDH-1)

z

Source VC4: VC4-3

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

z

Source Timeslot Range(e.g.1,3-6): 1–5

z

Sink Slot: 13-N2SL4-1(SDH-1)

z

Sink VC4: VC4-3

z

Sink Timeslot Range(e.g.1,3-6): 1–5

z

Activate Immediately: Yes

z

Click Apply.

Step 5 Repeat 4 to set as follows in the dialog box. z

Level: VC3

z

Direction: Bidirectional

z

Source Slot: 12-N2SL16-1(SDH-1)

z

Source VC4: VC4-4

z

Source Timeslot Range(e.g.1,3-6): 1

z

Sink Slot: 13-N2SL4-1(SDH-1)

z

Sink VC4: VC4-4

z

Sink Timeslot Range(e.g.1,3-6): 1

z

Activate Immediately: Yes

z

Click OK.

----End

3.1.4 Configuration Process (by Trail) Ethernet service can be created by trail or by station. If you purchase the license with trail management function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by station.

Table 3-5 shows the process of creating point-to-point EPL service on the T2000. Table 3-5 Process of creating point-to-point EPL service (by trail) Procedure

Action

Remarks

1

Create a server trail

See section 1.4.10 of chapter 1

2

Create a trunk link

3

Create an EPL trail

Create a Trunk Link Step 1 Select Trail > Trunk Link Creation from the main menu. Step 2 Set Bandwidth to 5 x VC12 in the pop-up interface. Step 3 Click Browse. Select the source NE (NE1), and click OK.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-15

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Step 4 Select the N1EFS4 board, then select VCTRUNK port 1 and select VC4:4-VC12:1–VC4:4-VC12:5 for available timeslot. Click OK.

Step 5 Click Browse. Select the sink NE (NE5). Select the N1EFS4 board, and select N1EFS4, then select VCTRUNK port 1 and VC4:4-VC12:1–VC4:4-VC12:5 for Available Timeslot. Click OK. Step 6 Select the Activate check box, and leave default setting for others.

Step 7 Click Apply to create the trunk link from NE1 to NE5 of user A.

3-16

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Step 8 Repeat 2–7 to create the trunk link from NE1 to NE5 of user B. ----End

Create an EPL Trail Step 1 Select Trail > Ethernet Trail Creation > EPL Creation from the main menu. Step 2 Set source parameters in the pop-up interface. z

Port Usage Strategy: Port

z

Click Browse and select a proper source line port: NE 1-13-N1EFS4-PORT1.

z

Set sink parameters.

z

Port Usage Strategy: Port

z

Click Browse and select a proper sink line port: NE 5-15-N1EFS4-PORT1.

z

Trunk Link Route Strategy: Use Existing Trunk Link.

z

Select Trunk_Link-0001 with bandwidth being 5 x VC12.

z

Click Next.

Step 3 Set port attributes in the pop-up interface.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-17

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services z

z

For PORT1 of NE1: −

TAG: Access



Enable port: Enable

Set PORT1 of NE5 similarly.

Step 4 Click Finish. Step 5 Repeat 1–4 to create EPL service of user B similarly.

----End

3.2 Configuring the PORT Shared EPL Service 3.2.1 Engineering Requirements The headquarters of company C is located in NE1, with two branches (M&S Department and Technical Support Department) located in NE5. The headquarters needs to communicate with two branches. The service of the two branches is required to be isolated completely, each occupying 10 Mbit/s bandwidth. The Ethernet switch of company C provides 100 Mbit/s Ethernet electrical interfaces. The Ethernet switch of headquarters supports virtual local area network (VLAN), but the interconnected equipment of the two branches does not.

3.2.2 Engineering Planning The engineering design department conducts planning based on the above requirements and the engineering information described in Chapter 1, and outputs the following engineering information:

3-18

z

Networking Diagram

z

Board Information of Each NE

z

Service Configuration Diagram of Each NE

z

Timeslot Allocation Diagram

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Networking Diagram Figure 3-6shows the Ethernet service networking and port allocation. Figure 3-6 Ethernet service networking and port allocation C (Headquarters) NE1

T2000

PORT3

PORT1

C(1)

PORT2

C(2)

PORT3

A

NE2

B

PORT4

NE4

NE5 PORT1

PORT2

NE3

VC-Trunk

A

B

Board Information of Each NE NE1 and NE5 do not require any new board.

Service Configuration Diagram of Each NE Figure 3-7shows the service configuration diagram of NE1 and NE5. Figure 3-7 Service configuration diagram

PORT

A

VCTRUNK

VCTRUNK

PORT1

PORT1

10M

10M

VCTRUNK1

VCTRUNK1 VC4-4:VC12-1~VC12-5

B

PORT

PORT2

PORT2 VCTRUNK2

40M

VC4-1:VC-3-1

VCTRUNK2

SDH

C

VC4-4:VC12-6~VC12-10

C1

VC4-4:VC12-6~VC12-10

PORT4 VCTRUNK4

VCTRUNK4 VC4-4:VC12-11~VC12-15

10M

VCTRUNK3

VCTRUNK3

B

40M

VC4-1:VC-3-1

PORT3 PORT3

A

VC4-4:VC12-1~VC12-5

NE1

C2

10M

VC4-4:VC12-11~VC12-15

NE5

Table 3-6 shows the Ethernet service connection table.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-19

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Table 3-6 Ethernet service connection table Service

C

Attribute Source NE

NE1

Source board - port

13-N1EFS4-3

Source Timeslot range

VC4-4: VC12-6–VC12-10

VC4-4: VC12-11–VC12-15

Source VCTRUNK

VCTRUNK3

VCTRUNK4

Working mode of source PORT

Auto negotiation

Auto negotiation

TAG flag of source PORT

Tag aware

Tag aware

Source VLAN ID

3

4

Bound bandwidth

5 x VC12

5 x VC12

Sink NE

NE5

Sink board - port

15-N1EFS4-3

15-N1EFS4-4

Sink Timeslot range

VC4-4: VC12-6–VC12-10

VC4-4: VC12-11–VC12-15

Sink VCTRUNK

VCTRUNK3

VCTRUNK4

Working mode of sink PORT

Auto negotiation

Auto negotiation

TAG flag of sink PORT

Access

Access

Sink VLAN ID

3

4

Timeslot Allocation Diagram The SDH timeslot allocation for Ethernet services is shown in Figure 3-8.

3-20

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Figure 3-8 Timeslot allocation diagram Ring Station NE1 12-SL16-1 Timeslot

NE4 NE2 NE3 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1

NE1 7-SL16-1

VC-12: 6-15 VC4-3

13-EFS4: VC4-4

Chain Station NE4 13-SL4-1 Timeslot

NE5 7-SL4-1

VC-12: 6-15 VC4-3

15-EFS4: VC4-4 Forwared Add/Drop

3.2.3 Configuration Process(by Station) Table 3-7 shows the process of configuring the PORT shared Ethernet EPL service on the T2000. Table 3-7 Process of PORT shared EPL service configuration Procedure

Description

Remarks

1

Creating a board

Not required in this section

2

Configuring Ethernet interfaces

3

Configuring bound paths

4

Creating the PORT shared EPL service

5

Configuring CAR

6

Configuring the cross-connect from Ethernet boards to SDH line boards

Optional

The configuration of the PORT shared EPL service is the same as that of the point-to-point EPL service, except that the Ethernet service configuration on NE1 and interface attributes are different.

Configuring NE1 Data Step 1 Configuring Ethernet interfaces 1.

Right click the NE1 icon in the Main Topology, and select NE Explorer.

2.

Select 13-N1EFS4 from the Object Tree and Configuration > Ethernet Interface . Management > Ethernet Interface from the Function Tree. Then, click

3.

Select External Port, and set as follows.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-21

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services −

Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT3 to Enabled. Click Apply.



Select the TAG Attribute tab. Set the TAG of the PORT3 to Tag Aware.



Other items adopt the default value. Click Apply.

Step 2 Configuring bound paths 1.

Select the Bound Path tab from the Internal Port page.

2.

Click Configuration, and the Bound Path Configuration dialog box is displayed.

3.

To set bound paths for VCTRUNK3, set as follows in the dialog box.

4.



Configurable Ports: VCTRUNK3



Level: VC12-xv



Direction: Bidirectional



Available Resources: VC4-4



Select VC12-6 to VC12-10 from the Available Timeslots one by one, and then click .

To set bound paths for VCTRUNK4, set as follows in the dialog box. −

Configurable Ports: VCTRUNK4



Level: VC12-xv



Direction: Bidirectional



Available Resources: VC4-4



Select VC12-11 to VC12-15 from the Available Timeslots one by one, and then click .



Click OK.

Step 3 Creating the PORT shared EPL service 1.

Select Configuration > Ethernet Service > Ethernet Line Service from the Function Tree.

2.

Click New and the Create Ethernet Line Service dialog box is displayed.

3.

According to Figure 3-7, set as follows to create the service from C to C1.

4.

3-22



Service Type: EPL



Service Direction: Bidirectional



Source Port: PORT3



Source VLAN: 3



Sink Port: VCTRUNK3



Sink VLAN: 3



Click Apply.

Repeat 3 to create the service from C to C2. Set as follows in the dialog box. −

Service Type: EPL



Service Direction: Bidirectional



Source Port: PORT3



Source VLAN: 4



Sink Port: VCTRUNK4



Sink VLAN: 4

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide −

3 Configuring Ethernet Services

Click OK.

Step 4 Configuring the cross-connect from Ethernet boards to SDH line boards 1.

Select NE1 from the Object Tree.

2.

Select Configuration > SDH Service Configuration from the Function Tree.

3.

Click Create, and the Create SDH Service dialog box is displayed.

4.

Set as follows in the dialog box. −

Level: VC12



Direction: Bidirectional



Source Slot: 13-N1EFS4-1(SDH-1)



Source VC4: VC4-4



Source Timeslot Range(e.g.1,3-6): 6–15



Sink Slot: 7-N2SL16-1(SDH-1)



Sink VC4: VC4-3



Sink Timeslot Range(e.g.1,3-6): 6–15



Activate Immediately: Yes



Click OK.

----End

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-23

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Configuring NE5 Data The data configuration of NE5 is performed in the similar way, except that some parameters are different.

Step 1 Configuring Ethernet interfaces 1.

Click the NE switching shortcut icon

2.

Select 15-N1EFS4 from the Object Tree and Configuration > Ethernet Interface Management > Ethernet Interface from the Function Tree, and then click .

3.

Select External Port, and set as follows.

. Select NE5, and click OK.



Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT3 and PORT4 to Enabled. Click Apply.



Select the TAG Attribute tab. Set the TAG of the PORT3 and PORT4 to Access. Set the Default VLAN ID of the PORT3 to 3. Set the Default VLAN ID of the PORT4 to 4.



Other items adopt the default value. Click Apply.

Step 2 Configuring bound paths 1.

Select the Bound Path tab from the Internal Port page.

2.

Click Configuration, and the Bound Path Configuration dialog box is displayed.

3.

To set bound paths for VCTRUNK3, set as follows in the dialog box.

4.



Configurable Ports: VCTRUNK3



Level: VC12-xv



Direction: Bidirectional



Available Resources: VC4-4



Select VC12-6 to VC12-10 from the Available Timeslots one by one, and then click .

To set bound paths for VCTRUNK4, set as follows in the dialog box. −

Configurable Ports: VCTRUNK4



Level: VC12-xv



Direction: Bidirectional



Available Resources: VC4-4



Select VC12-11 to VC12-15 from the Available Timeslots one by one, and then click .



Click OK.

Step 3 Creating the PORT shared EPL service

3-24

1.

Select Configuration > Ethernet Service > Ethernet Line Service from the Function Tree.

2.

Click New, and the Create Ethernet Line Service dialog box is displayed.

3.

According to Figure 3-7, set as follows to create the service from C1 to C. −

Service Type: EPL



Service Direction: Bidirectional



Source Port: PORT3

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

4.

3 Configuring Ethernet Services



Source VLAN: 3



Sink Port: VCTRUNK3



Sink VLAN: 3



Click Apply.

Repeat 3 to create the service from C2 to C. Set as follows in the dialog box. −

Service Type: EPL



Service Direction: Bidirectional



Source Port: PORT4



Source VLAN: 4



Sink Port: VCTRUNK4



Sink VLAN: 4



Click OK.

Step 4 Configuring the cross-connect from Ethernet boards to SDH line boards 1.

Select NE5 from the Object Tree.

2.

Select Configuration > SDH Service Configuration from the Function Tree.

3.

Click Create, and the Create SDH Service dialog box is displayed.

4.

Set as follows in the dialog box. −

Level: VC12



Direction: Bidirectional



Source Slot: 15-N1EFS4-1(SDH-1)



Source VC4: VC4-4



Source Timeslot Range(e.g.1,3-6): 6-15



Sink Slot: 7-N2SL4-1(SDH-1)



Sink VC4: VC4-3



Sink Timeslot Range(e.g.1,3-6): 6-15



Activate Immediately: Yes



Click OK.

----End

Configuring NE4 Data The Ethernet service of NE4 to be configured is pass-through service. Follow the steps below to configure NE4 data. Step 1 Click the NE switching shortcut icon

. Select NE4, and click OK.

Step 2 Select Configuration > SDH Service Configuration from the Function Tree. Step 3 Click Create, and the Create SDH Service dialog box is displayed. Step 4 Set as follows in the dialog box. z

Level: VC12

z

Direction: Bidirectional

z

Source Slot: 12-N2SL16-1(SDH-1)

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-25

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services z

Source VC4: VC4-3

z

Source Timeslot Range(e.g.1,3-6): 6–15

z

Sink Slot: 13-N2SL4-1(SDH-1)

z

Sink VC4: VC4-3

z

Sink Timeslot Range(e.g.1,3-6): 6–15

z

Activate Immediately: Yes

z

Click OK.

----End

3.2.4 Configuration Process (by Trail) Ethernet service can be created by trail or by station. If you purchase the license with trail management function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by station.

Table 3-8 shows main procedures of creating PORT shared EPL service on the T2000. Table 3-8 Process of creating PORT-shared EPL service (by trail) Procedure

Description

Remarks

1

Creating a server trail

See section 1.4.10 of Chapter 1

2

Creating a trunk link

3

Creating an EPL trail

Creating a Trunk Link Follow the steps below to create a trunk link. Step 1 Select Trail > Trunk Link Creation from the main menu. Step 2 Set Bandwidth to 5 x VC12 in the interface displayed. Step 3 Click Browse. Select the source NE (NE1). Step 4 In the pop-up interface, select the N1EFS4 board, then select VCTRUNK port 3 and select VC4:4-VC12:6–VC4:4-VC12:10 for available timeslot. Click OK. Step 5 Click Browse. Select the sink NE (NE5). In the pop-up interface, select N1EFS4, VCTRUNK port 3 and VC4:4-VC12:6–VC4:4-VC12:10 for available timeslot. Step 6 Select the Activate check box, and leave the default setting for others.

3-26

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Step 7 Click Apply to create the trunk link from C of NE1 to C1 of NE5. Step 8 Repeat steps 2–7 to create the trunk link from C of NE1 to C2 of NE5. ----End

Creating an EPL Trail Follow the steps below to create an EPL trail. Step 1 Select Trail > Ethernet Trail Creation > EPL Creation from the main menu. Step 2 Set source parameters in the pop-up interface. z

Port Usage Strategy: Port+VLAN

z

Click Browse and select a proper source line port: NE1-13-N1EFS4-PORT3.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-27

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services z

VLAN ID: 3

z

Set sink parameters.

z

Port Usage Strategy: Port+VLAN

Step 3 Click Browse and select a proper sink line port: NE5-15-N1EFS4-PORT3 z

VLAN ID: 3.

z

Trunk Link Route Strategy: Use Existing Trunk Links.

z

Select Trunk_Link-0003 with bandwidth being 5 x VC12.

z

Click Next.

Step 4 Set port attributes in the pop-up interface. z

For PORT3 of NE1:

z

TAG: Tag Aware

z

Enable Port: Enable

z

For PORT3 of NE5:

z

TAG: Access

z

Enable Port: Enable

z

Select the Activate check box.

z

Click Finish.

Step 5 Repeat steps 1–4 to create an EPL trail from C of NE1 to C2 of NE5.

3-28

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

----End

3.3 Configuring the VCTRUNK Shared EPL Service 3.3.1 Engineering Requirements D and D' are users of integrated intelligent communities and located in NE2 and NE3 respectively. They need to communicate with each other. E and E' are users of large corporations and located in NE2 and NE3 respectively. They also need to communicate with each other. Services of communities and that of corporations are isolated completely. Because the traffic peak of community services is at night and that of corporation services is in daytime, they can share a 300 Mbit/s bandwidth. Their Ethernet equipment provides GE optical interfaces but does not support VLAN.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-29

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

3.3.2 Engineering Planning The engineering design department conducts planning based on the above requirements and the engineering information described in Chapter 1, and outputs the following engineering information. z

Networking Diagram

z

Board Information of Each NE

z

Service Configuration Diagram of Each NE

z

Timeslot Allocation Diagram

Networking Diagram Figure 3-9 shows the Ethernet service networking and port allocation. Figure 3-9 Ethernet service networking and port allocation

NE1 T2000

D

PORT1

NE2

E

B

NE4 NE5

PORT2

NE3 PORT1

D’

PORT2

VC-Trunk

E’

Board Information of Each NE Ethernet boards need to be added according to the added service type and traffic volume. NE2 and NE3 are added with one N2EGS2 board respectively. Other NEs remain unchanged. Figure 3-10 shows the board layout of NE2 and NE3.

3-30

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Figure 3-10 Board layout of NE2 and NE3

AUX

FAN S 1 0

FAN

GSCC GSCC

S S S S S S S S 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8 SL16 N2EGS2

SL16

GXCSA

S S S S S S S S S 1 2 3 4 5 6 7 8 9

GXCSA

FAN

PQ1

S S S S S S S S S 2 3 3 3 3 3 3 3 3 9 0 1 2 3 4 5 6 7

PIU

S 2 8

PIU

D75S D75S

S S S S S S S S S 1 2 2 2 2 2 2 2 2 9 0 1 2 3 4 5 6 7

Service Configuration Diagram of Each NE Figure 3-11shows the service configuration of NE2 and NE3. Figure 3-11 Service configuration diagram MAC

D E

VCTRUNK

VCTRUNK

PORT1

MAC PORT1

D’

300M

300M

PORT2

VCTRUNK1

300M

VC4-1:VC3-1~VC3-3 VC4-2:VC3-1~VC3-3

PORT2

VCTRUNK1

SDH

VC4-1:VC3-1~VC3-3 VC4-2:VC3-1~VC3-3

NE2

300M

E’

NE3

Table 3-9 shows the Ethernet service connection table.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-31

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Table 3-9 Ethernet service connection table Service

D

E

Attribute Source NE

NE2

Source board - port

13-N2EGS2-1

Source Timeslot range

VC4-1: VC3-1 to VC3-3

13-N2EGS2-2

VC4-2: VC3-1 to VC3-3 Source VCTRUNK

VCTRUNK1

Working mode of source PORT

1000M full duplex

1000M full duplex

TAG flag of source PORT

Access

Access

VLAN ID of source PORT

1

2

Bound bandwidth

6 x VC-3

Sink NE

NE3

Sink board - port

13-N2EGS2-1

Sink Timeslot range

VC4-1: VC3-1 to VC3-3

13-N2EGS2-2

VC4-2: VC3-1 to VC3-3 Sink VCTRUNK

VCTRUNK1

Working mode of sink PORT

1000M full duplex

1000M full duplex

TAG flag of sink PORT

Access

Access

VLAN ID of sink PORT

1

2

Timeslot Allocation Diagram Figure 3-12 shows the SDH timeslot allocation. Figure 3-12 SDH timeslot allocation for Ethernet services Ring Station NE1 12-SL16-1

Timeslot

NE4 NE3 NE2 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1

NE1 7-SL16-1

VC-3: 1-3

VC4-3

13-EGS2: VC4-1 VC-3: 1-3

VC4-4

13-EGS2: VC4-2 Forward Add/Drop

3-32

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

3.3.3 Configuration Process(by Station) Table 3-10 shows the process of configuring the VCTRUNK shared EPL service on the T2000. Table 3-10 Process of VCTRUNK shared EPL service configuration Procedure

Description

1

Creating a board

2

Configuring Ethernet interfaces

3

Configuring bound paths

4

Creating the VCTRUNK shared EPL service

5

Configuring CAR

6

Configuring the cross-connect from Ethernet boards to SDH line boards

Remarks

Optional.

Creating a Board Follow the steps below to create a board. Step 1 In the Main Topology, double click the NE2 icon to open the NE panel. Step 2 Right click slot 13 according to the board layout of NE1 shown in Figure 3-10, and select N2EGS2. Step 3 Make sure the N2EGS2 board is configured in slot 13, and click

.

Step 4 Repeat steps 1–3 to create the Ethernet board of NE3. Figure 3-10 shows the board layout of NE3. ----End

Configuring NE2 Data See theT2000 online help for the meaning of each parameter during service configuration.

Step 1 Configuring Ethernet interfaces 1.

Right click the NE2 icon in the Main Topology, and select NE Explorer.

2.

Select 13-N2EGS2 from the Object Tree and Configuration > Ethernet Interface . Management > Ethernet Interface from the Function Tree, and then click

3.

Select External Port, and set as follows. Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 and PORT2 to Enabled. Set the Working mode of the PORT1 and PORT2 to 1000M Full-Duplex. Click Apply.

4.

Select the TAG Attribute tab. Set the TAG of the PORT1 and PORT2 to Access. Set the Default VLAN ID of the PORT1 to 1. Set the Default VLAN ID of the PORT2 to 2. Other items adopt the default value. Click Apply.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-33

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Step 2 Configuring bound paths 1.

Select the Bound Path tab from the Internal Port page.

2.

Click Configuration, and the Bound Path Configuration dialog box is displayed.

3.

To set bound paths for VCTRUNK1, set as follows in the dialog box. −

Configurable Ports: VCTRUNK1



Level: VC3-xv



Direction: Bidirectional



Available Resources: VC4-1



Select VC3-1 to VC3-3 from the Available Timeslots, and then click



Available Resources: VC4-2



Select VC3-1 to VC3-3 from the Available Timeslots, and then click



Click OK.

. .

Step 3 Creating the VCTRUNK shared EPL service

3-34

1.

Select Configuration > Ethernet Service > Ethernet Line Service from the Function Tree.

2.

Click New, and the Create Ethernet Line Service dialog box is displayed.

3.

According to Figure 3-11, set as follows to create the service of D. −

Service Type: EPL



Service Direction: Bidirectional



Source Port: PORT1



Source VLAN: 1



Sink Port: VCTRUNK1



Sink VLAN: 1



Click Apply.

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

4.

3 Configuring Ethernet Services

Repeat 3 to create the service of E. Set as follows in the dialog box. −

Service Type: EPL



Service Direction: Bidirectional



Source Port: PORT2



Source VLAN: 2



Sink Port: VCTRUNK1



Sink VLAN: 2



Click OK.

Step 4 Configuring the cross-connect from Ethernet boards to SDH line boards 1.

Select NE2 from the Object Tree.

2.

Select Configuration > SDH Service Configuration from the Function Tree.

3.

Click Create, and the Create SDH Service dialog box is displayed.

4.

Set as follows in the dialog box.

Issue 01 (2006-09-20)



Level: VC3



Direction: Bidirectional



Source Slot: 13-N2EGS2-1(SDH-1)

Huawei Technologies Proprietary

3-35

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

5.



Source VC4: VC4-1



Source Timeslot Range(e.g.1,3-6): 1–3



Sink Slot: 12-N2SL16-1(SDH-1)



Sink VC4: VC4-3



Sink Timeslot Range(e.g.1,3-6): 1–3



Activate Immediately: Yes



Click Apply.

Repeat 4 to set as follows in the dialog box. −

Level: VC3



Direction: Bidirectional



Source Slot: 13-N2EGS2-1(SDH-1)



Source VC4: VC4-2



Source Timeslot Range(e.g.1,3-6): 1–3



Sink Slot: 12-N2SL16-1(SDH-1)



Sink VC4: VC4-4



Sink Timeslot Range(e.g.1,3-6): 1–3



Activate Immediately: Yes



Click OK.

----End

3-36

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Configuring NE3 Data The data configuration of NE3 is the same as that of NE2.

Step 1 Configuring Ethernet interfaces 1.

Click the NE switching shortcut icon

2.

Select 13-N2EGS2 from the Object Tree and Configuration > Ethernet Interface Management > Ethernet Interface from the Function Tree, and then click .

3.

Select External Port, and set as follows.

. Select NE3, and click OK.



Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 and PORT2 to Enabled. Set the Working mode of the PORT1 and PORT2 to 1000M Full-Duplex. Click Apply.



Select the TAG Attribute tab. Set the TAG of the PORT1 and PORT2 to Access. Set the Default VLAN ID of the PORT1 to 1. Set the Default VLAN ID of the PORT2 to 2.



Other items adopt the default value. Click Apply.

Step 2 Configuring bound paths 1.

Select the Bound Path tab from the Internal Port page.

2.

Click Configuration, and the Bound Path Configuration dialog box is displayed.

3.

To set bound paths for VCTRUNK1, set as follows in the dialog box. −

Configurable Ports: VCTRUNK1



Level: VC3-xv



Direction: Bidirectional



Available Resources: VC4-1



Select VC3-1 to VC3-3 from the Available Timeslots, and then click



Available Resources: VC4-2



Select VC3-1 to VC3-3 from the Available Timeslots, and then click



Click OK.

. .

Step 3 Creating the VCTRUNK shared EPL service 1.

Select Configuration > Ethernet Service > Ethernet Line Service from the Function Tree.

2.

Click New, and the Create Ethernet Line Service dialog box is displayed.

3.

According to Figure 3-11, set as follows to create the EPL service for D.

4.

Issue 01 (2006-09-20)



Service Type: EPL



Service Direction: Bidirectional



Source Port: PORT1



Source VLAN: 1



Sink Port: VCTRUNK1



Sink VLAN: 1



Click Apply.

Repeat 3 to create the EPL service for E. Set as follows in the dialog box.

Huawei Technologies Proprietary

3-37

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services −

Service Type: EPL



Service Direction: Bidirectional



Source Port: PORT2



Source VLAN: 2



Sink Port: VCTRUNK1



Sink VLAN: 2



Click OK.

Step 4 Configuring the cross-connect from Ethernet boards to SDH line boards 1.

Select NE3 from the Object Tree.

2.

Select Configuration > SDH Service Configuration from the Function Tree.

3.

Click Create, and the Create SDH Service dialog box is displayed.

4.

Set as follows in the dialog box.

5.



Level: VC3



Direction: Bidirectional



Source Slot: 13-N2EGS2-1(SDH-1)



Source VC4: VC4-1



Source Timeslot Range(e.g.1,3-6): 1–3



Sink Slot: 7-N2SL16-1(SDH-1)



Sink VC4: VC4-3



Sink Timeslot Range(e.g.1,3-6): 1–3



Activate Immediately: Yes



Click Apply.

Repeat 4 to set as follows in the dialog box. −

Level: VC3



Direction: Bidirectional



Source Slot: 13-N2EGS2-1(SDH-1)



Source VC4: VC4-2



Source Timeslot Range(e.g.1,3-6): 1–3



Sink Slot: 7-N2SL16-1(SDH-1)



Sink VC4: VC4-4



Sink Timeslot Range(e.g.1,3-6): 1–3



Activate Immediately: Yes



Click OK.

----End

3.3.4 Configuration Process (by Trail) Ethernet service can be created by trail or by station. If you purchase the license with trail management function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by station.

Table 3-11 shows the process of creating VCTRUNK shared EPL service on the T2000.

3-38

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Table 3-11 Process of creating VCTRUNK-shared EPL service (by trail) Procedure

Action

Remarks

1

Create a server trail

See section 1.4.10 of chapter 1

2

Create a trunk link

3

Create an EPL trail

Create a Trunk Link Step 1 Select Trail > Trunk Link Creation from the main menu. Step 2 Set Bandwidth to 6 x VC3 in the pop-up interface. Step 3 Click Browse. Select the source NE (NE2). Step 4 In the pop-up interface, select the N2EGS2 board, then select VCTRUNK Port 1, 1 and 2 for Higher Order and VC4:1-VC3:1–VC4:1-VC3:3 and VC4:2-VC3:1–VC4:2-VC3:3 for available timeslot. Click OK.

Step 5 Click Browse. Select the sink NE (NE3). In the pop-up interface, select N2EGS2, VCTRUNK port 1, 1 and 2 for Higher Order, and VC4:1-VC3:1–VC4:1-VC3:3 and VC4:2-VC3:1–VC4:2-VC3:3 for available timeslot. Step 6 Select the Activate check box, and leave the default setting for others.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-39

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Step 7 Click Apply to create the trunk link from NE2 to NE3 shared by users D, D', E, and E'. ----End

Create an EPL Trail Step 1 Select Trail > Ethernet Trail Creation > EPL Creation from the main menu. Step 2 Set source parameters in the pop-up interface. z

Port Usage Strategy: Port+VLAN

z

Click Browse and select a proper source line port: NE2-13-N2EGS2-PORT1.

z

VLAN ID: 1

Step 3 Set sink parameters.

3-40

z

Port Usage Strategy: Port+VLAN

z

Click Browse and select a proper source line port: NE3-13-N2EGS2-PORT1.

z

VLAN ID: 1.

z

Trunk Link Route Strategy: Use Existing Trunk Link.

z

Select the trunk link with bandwidth being 6 x VC3.

z

Click Next.

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Step 4 Set port attributes in the pop-up interface. z

z

z

For PORT1 of NE2: −

TAG: Access



Enable Port: Enable

For PORT1 of NE3: −

TAG: Access



Enable Port: Enable

Select the Activate check box.

Step 5 Click Finish to create the EPL trail from D of NE2 to D' of NE3. Step 6 Repeat steps 1–5 to create an EPL trail from E of NE2 to E' of NE3. ----End

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-41

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

3.4 Configuring the EPLn Service 3.4.1 Engineering Requirements Company F has three branches located in NE2, NE3 and NE4 respectively. The information needs to be shared between the branches, and any two branches can visit each other. The three branches share a 10 Mbit/s bandwidth dynamically. The Ethernet equipment of company F provides 100 Mbit/s Ethernet interfaces.

3.4.2 Engineering Planning The engineering design department conducts planning based on the above requirements and the engineering information described in Chapter 1, and outputs the following engineering information. z

Networking Diagram

z

Board Information of Each NE

z

Service Configuration Diagram of Each NE

z

Timeslot Allocation Diagram

Networking Diagram Figure 3-13 shows the Ethernet service networking and port allocation. Figure 3-13 Ethernet service networking and port allocation

NE1

T2000

VCTRUNK1

VB PORT1

VB

VCTRUNK1

NE2

PORT1

B

NE4

PORT1

PORT1

NE3 F1

NE5

F3 VCTRUNK

PORT1 VCTRUNK1

F2

VB

VCTRUNK2

PORT1

Board Information of Each NE Ethernet boards need to be added according to the added service type and traffic volume. NE2, NE3 and NE4 are added with one N2EFS0 board respectively. Other NEs remain unchanged. Figure 3-14 and Figure 3-15 show the board layout of NE2 and NE3, and NE4 respectively.

3-42

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Figure 3-14 Board layout of NE2 and NE3

AUX

PIU FAN S 1 0

GSCC GSCC

GXCSA

N2EFS0

S S S S S S S S 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8

GXCSA

S S S S S S S S S 1 2 3 4 5 6 7 8 9

SL16

FAN

SL16 N2EGS2

FAN

PQ1

S S S S S S S S S 2 3 3 3 3 3 3 3 3 9 0 1 2 3 4 5 6 7

ETF8

S 2 8

PIU

D75S D75S

S S S S S S S S S 1 2 2 2 2 2 2 2 2 9 0 1 2 3 4 5 6 7

Figure 3-15 Board layout of NE4

FAN S 1 0

FAN

GSCC GSCC

N2EFS0

SL4 PL3

SL16

S S S S S S S S 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8

GXCSA

GXCSA

SL16

S S S S S S S S S 1 2 3 4 5 6 7 8 9

AUX

ETF8

PIU

FAN

PQ1 PQ1

S S S S S S S S S 2 3 3 3 3 3 3 3 3 9 0 1 2 3 4 5 6 7

C34S

S 2 8

PIU

D75S D75S D75S D75S

S S S S S S S S S 1 2 2 2 2 2 2 2 2 9 0 1 2 3 4 5 6 7

Service Configuration Diagram of Each NE Figure 3-16 shows the service configuration of NE2, NE3 and NE4.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-43

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Figure 3-16 Service configuration diagram PORT

VCTRUNK LP2

PORT

VCTRUNK

LP1 PORT1 10M

VCTRUNK1 VC4-4:VC12-1~VC12-5

F1

VB1

LP2

F2

PORT1 LP1

NE2

VCTRUNK1

LP3

10M

VB1

VC4-4:VC12-1~VC12-5

VCTRUNK2

PORT

VCTRUNK

VC4-4:VC12-6~VC12-10

NE3

LP2

LP1 PORT1

SDH

F3

10M

VCTRUNK1 VC4-4:VC12-1~VC12-5

VB1 NE4

Table 3-12shows the Ethernet service connection table. Table 3-12 Ethernet service connection table Service

F

Attribute

3-44

Source NE

NE3

Source board - port

14-N2EFS0-1

Source Timeslot range

VC4-4: VC12-1–VC12-5

VC4-4: VC12-6–VC12-10

Source VCTRUNK

VCTRUNK1

VCTRUNK2

Source VCTRUNK attribute

PE

PE

Working mode of source PORT

Auto negotiation

TAG flag of source PORT

Access

VLAN ID of source PORT

11 (Set as the user's demand)

VB

VB1

Attached port

PORT1, VCTRUNK1, VCTRUNK2

Sink NE

NE2

NE4

Sink board - port

14-N2EFS0-1

15-N2EFS0-1

Sink Timeslot range

VC4-4: VC12-1–VC12-5

VC4-4: VC12-1–VC12-5

Sink VCTRUNK

VCTRUNK1

VCTRUNK1

Sink VCTRUNK attribute

PE

PE

Working mode of sink PORT

Auto negotiation

Auto negotiation

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Service

F

Attribute TAG flag of sink PORT

Access

Access

VLAN ID of sink PORT

11

11

Virtual bridge (VB)

VB1

VB1

Attached port

PORT1, VCTRUNK1

PORT1, VCTRUNK1

Table 3-13 shows the forwarding filter table of NE2, NE3 and NE4. Table 3-13 Forwarding filter table NE name

VB

VLAN ID

Forwarding port

NE2

VB1

11

PORT1, VCTRUNK1

NE3

VB1

11

PORT1, VCTRUNK1, VCTRUNK2

NE4

VB1

11

PORT1, VCTRUNK1

Timeslot Allocation Diagram Figure 3-17 shows the SDH timeslot allocation. Figure 3-17 SDH timeslot allocation for Ethernet services Ring Station NE1 12-SL16-1 Timeslot

NE4 NE2 NE3 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 VC-12: 1-5

VC4-5

14-EFS0: VC4-4

NE1 7-SL16-1

VC-12: 1-5 15-EFS0: VC4-4

Forward Add/Drop

3.4.3 Configuration Process(by Station) Table 3-14 shows the process of configuring the EPLn service on the T2000.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-45

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Table 3-14 Process of EPLn service configuration Procedure

Description

1

Creating a board

2

Configuring Ethernet interfaces

3

Configuring bound paths

4

Creating the EPLn service

5

Configuring the VLAN forwarding filter table

6

Configuring CAR

7

Configuring the cross-connect from Ethernet boards to SDH line boards

Remarks

Optional, see 3.1.3

Creating a Board Step 1 In the Main Topology, double click the NE2 icon to open the NE panel. Step 2 Right click slot 14 according to Figure 3-14, and then select N2EFS0. Right click slot 31, and then select ETF8. Step 3 Make sure the N2EFS0 and ETF8 boards are configured in slots 14 and 31, and then click Close. Step 4 Repeat steps 1–3 to create the Ethernet board for NE3 and NE4. Figure 3-14 and Figure 3-15 show the board layout of NE3 and NE4 respectively. ----End

Configuring NE2 Data See the NM online help for the meaning of each parameter during service configuration.

Step 1 Configuring Ethernet interfaces 1.

Right click the NE2 icon in the Main Topology, and select NE Explorer.

2.

Select 14-N2EFS0 from the Object Tree and Configuration > Ethernet Interface . Management > Ethernet Interface from the Function Tree, and then click

3.

Select External Port, and set as follows. −

Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 to Enabled. Click Apply.



Select the TAG Attribute tab. Set the TAG of the PORT1 to Access. Set the Default VLAN ID of the PORT1 to 11.



Other items adopt the default value. Click Apply.

Step 2 Configuring bound paths

3-46

1.

Select the Bound Path tab from the Internal Port page.

2.

Click Configuration, and the Bound Path Configuration dialog box is displayed.

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3.

3 Configuring Ethernet Services

To set bound paths for VCTRUNK1, set as follows in the dialog box. −

Configurable Ports: VCTRUNK1



Level: VC12-xv



Direction: Bidirectional



Available Resources: VC4-4



Select VC12-1 to VC12-5 from the Available Timeslots, and then click



Click OK.

.

Step 3 Creating the EPLn service 1.

Select Configuration > Ethernet Service > Ethernet LAN Service from the Function Tree.

2.

Click New and the Create Ethernet LAN Service dialog box is displayed.

3.

Set the VB name to VB1.

4.

Click Configure Mounted Port and the VB Mount Port Configuration dialog box is displayed.

5.

Set as follows in the dialog box according to the service configuration diagram of NE2. Select PORT1 and VCTRUNK1 for Available Mounted Ports, and click . Click OK.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-47

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

6.

Click OK in the Create Ethernet LAN Service dialog box.

Step 4 Configuring the VLAN forwarding filter table

3-48

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

1.

Select Configuration > Ethernet Service > Ethernet LAN Service from the Function Tree. Select VLAN tab.

2.

Click New and the Create VLAN dialog box is displayed.

3.

Set as following in the dialog box. −

VB: 1-VB1



VLAN ID: 11



Selected forwarding ports: PORT1 and VCTRUNK1



Click OK.

Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards 1.

Select NE2 from the Object Tree.

2.

Select Configuration > SDH Service Configuration from the Function Tree.

3.

Click Create and the Create SDH Service dialog box is displayed.

4.

Set as follows in the dialog box.

Issue 01 (2006-09-20)



Level: VC12



Direction: Bidirectional



Source Slot: 14-N2EFS0-1(SDH-1)



Source VC4: VC4-4



Source Timeslot Range(e.g.1,3-6): 1–5



Sink Slot: 12-N2SL16-1(SDH-1)



Sink VC4: VC4-5



Sink Timeslot Range(e.g.1,3-6): 1–5



Activate Immediately: Yes

Huawei Technologies Proprietary

3-49

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services −

Click OK.

----End

Configuring NE3 Data The data configuration of NE3 is performed in the same way as that of NE2, except that some parameters are different.

Step 1 Configuring Ethernet interfaces 1.

Click the NE switching shortcut icon

2.

Select 14-N2EFS0 from the Object Tree and Configuration > Ethernet Interface Management > Ethernet Interface from the Function Tree. Then, click .

3.

Select External Port, and set as follows.

. Select NE3, and click OK.



Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 to Enabled. Click Apply.



Select the TAG Attribute tab. Set the TAG of the PORT1 to Access. Set the Default VLAN ID of the PORT1 to 11.



Other items adopt the default value. Click Apply.

Step 2 Configuring bound paths 1.

3-50

Select the Bound Path tab from the Internal Port page.

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

2.

Click Configuration and the Bound Path Configuration dialog box is displayed.

3.

To set bound paths for VCTRUNK1, set as follows in the dialog box. −

Configurable Ports: VCTRUNK1



Level: VC12-xv



Direction: Bidirectional



Available Resources: VC4-4



Select VC12-1 to VC12-5 from the Available Timeslots, and then click



Configurable Ports: VCTRUNK2



Level: VC12-xv



Direction: Bidirectional



Available Resources: VC4-4



Select VC12-6 to VC12-10 from the Available Timeslots, and then click



Click OK.

.

.

Step 3 Creating the EPLn service 1.

Select Configuration > Ethernet Service > Ethernet LAN Service from the Function Tree.

2.

Click New and the Create Ethernet LAN Service dialog box is displayed.

3.

Set the VB name to VB1.

4.

Click Configure Mounted Port and the VB Mount Port Configuration dialog box is displayed.

5.

Set as follows in the dialog box according to the service configuration diagram of NE2. Select PORT1, VCTRUNK1 and VCTRUNK2 for Available Mounted Ports, and click . Click OK.

6.

Click OK in the Create Ethernet LAN Service dialog box.

Step 4 Configuring the VLAN Forward Filter Table 1.

Select Configuration > Ethernet Service > Ethernet LAN Service from the Function Tree. Select VLAN tab.

2.

Click New and the Create VLAN dialog box is displayed.

3.

Set as following in the dialog box. −

VB: 1-VB1



VLAN ID: 11



Selected forwarding ports: PORT1, VCTRUNK1 and VCTRUNK2



Click OK.

Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards 1.

Select NE3 from the Object Tree.

2.

Select Configuration > SDH Service Configuration from the Function Tree.

3.

Click Create and the Create SDH Service dialog box are displayed.

4.

Set as follows in the dialog box.

Issue 01 (2006-09-20)



Level: VC12



Direction: Bidirectional



Source Slot: 14-N2EFS0-1(SDH-1)

Huawei Technologies Proprietary

3-51

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

5.



Source VC4: VC4-4



Source Timeslot Range(e.g.1,3-6): 1–5



Sink Slot: 7-N2SL16-1(SDH-1)



Sink VC4: VC4-5



Sink Timeslot Range(e.g.1,3-6): 1–5



Activate Immediately: Yes



Click Apply.

Repeat 3–4 to set as follows in the dialog box. −

Level: VC12



Direction: Bidirectional



Source Slot: 14-N2EFS0-1(SDH-1)



Source VC4: VC4-4



Source Timeslot Range(e.g.1,3-6): 6–10



Sink Slot: 12-N2SL16-1(SDH-1)



Sink VC4: VC4-5



Sink Timeslot Range(e.g.1,3-6): 1–5



Activate Immediately: Yes



Click OK.

----End

Configuring NE4 Data The data configuration of NE4 is performed in the same way as that of NE2.

Step 1 Configuring Ethernet interfaces 1.

Click the NE switching shortcut icon

2.

Select 15-N2EFS0 from the Object Tree and Configuration > Ethernet Interface Management > Ethernet Interface from the Function Tree, and then click .

3.

Select External Port, and set as follows.

. Select NE4, and click OK.



Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 to Enabled. Click Apply.



Select the TAG Attribute tab. Set the TAG of the PORT1 to Access. Set the Default VLAN ID of the PORT1 to 11.



Other items adopt the default value. Click Apply.

Step 2 Configuring bound paths

3-52

1.

Select the Bound Path tab from the Internal Port page.

2.

Click Configuration and the Bound Path Configuration dialog box are displayed.

3.

To set bound paths for VCTRUNK1, set as follows in the dialog box. −

Configurable Ports: VCTRUNK1



Level: VC12-xv



Direction: Bidirectional

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services



Available Resources: VC4-4



Select VC12-1 to VC12-5 from the Available Timeslots, and then click



Click OK.

.

Step 3 Creating the EPLn service 1.

Select Configuration > Ethernet Service > Ethernet LAN Service from the Function Tree.

2.

Click New and the Create Ethernet LAN Service dialog box is displayed.

3.

Set the VB name to VB1.

4.

Click Configure Mounted Port and the VB Mount Port Configuration dialog box is displayed.

5.

Set as follows in the dialog box according to the service configuration diagram of NE2. Select PORT1 and VCTRUNK1 for Available Mounted Ports, and click . Click OK.

6.

Click OK in the Create Ethernet LAN Service dialog box.

Step 4 Configuring the VLAN forwarding filter table 1.

Select Configuration > Ethernet Service > Ethernet LAN Service from the Function Tree. Select VLAN tab.

2.

Click New and the Create VLAN dialog box is displayed.

3.

Set as following in the dialog box. −

VB: 1-VB1



VLAN ID: 11



Selected forwarding ports: PORT1 and VCTRUNK1



Click OK.

Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards 1.

Select NE4 from the Object Tree.

2.

Select Configuration > SDH Service Configuration from the Function Tree.

3.

Click Create and the Create SDH Service dialog box is displayed.

4.

Set as follows in the dialog box. −

Level: VC12



Direction: Bidirectional



Source Slot: 15-N2EFS0-1(SDH-1)



Source VC4: VC4-4



Source Timeslot Range(e.g.1,3-6): 1–5



Sink Slot: 7-N2SL16-1(SDH-1)



Sink VC4: VC4-5



Sink Timeslot Range(e.g.1,3-6): 1–5



Activate Immediately: Yes



Click OK.

----End

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-53

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

3.4.4 Configuration Process (by Trail) Ethernet service can be created by trail or by station. If you purchase the license with trail management function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by station.

Table 3-15 shows the process of creating EPLn service on the T2000. Table 3-15 Process of creating EPLn service (by trail) Procedure

Action

Remarks

1

Create a server trail

See section 1.4.10 of chapter 1

2

Create a trunk link

3

Create an EPLn trail

Create a Trunk Link Step 1 Select Trail > Trunk Link Creation from the main menu. Step 2 Set Bandwidth to 5 x VC12 in the pop-up interface. Step 3 Click Browse. Select the source NE (NE3). Step 4 In the pop-up interface, select the N2EFS0 board, then select VCTRUNK port 1, 4 for Higher Order, VC4:4-VC12:1–VC4:4-VC12:5 for available timeslot. Click OK.

Step 5 Click Browse. Select the sink NE (NE2). In the pop-up interface, select N2EFS0, then select VCTRUNK port 1, 4 for Higher Order, and VC4:4-VC12:1–VC4:4-VC12:5 for available timeslot (lower order). Step 6 Select the Activate check box, and leave the default setting for others.

3-54

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Step 7 Click Apply to create the trunk link from NE3 to NE2. Step 8 Create the trunk link from NE3 to NE4 similarly.

----End

Create an EPLn Trail Step 1 Select Trail > Ethernet Trail Creation > EPLn Creation from the main menu. Step 2 Set source parameters in the pop-up EPLn creation window. Double click the nodes (NE2–NE4) to be added into the EPLn. In the pop-up interface, click available ports and then click OK.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

to select

3-55

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Step 3 Select the trunk link created previously from Trunk Link Route Strategy and click Next.

Step 4 Set port attributes in the port attribute setting window. For PORT1 of NE2, NE3 and NE4:

3-56

z

TAG: Access

z

Port Enable: Enable

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Step 5 Click Add in the VLAN configuration window, and set the following parameter in the VLAN Configuration for Ethernet Trail window. z

VLAN ID: 11

z

Select the PORT and VCTRUNK, click

to select the port, and click OK.

Step 6 Click Next.

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-57

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

Step 7 Set the name to be EPLn, select the Activate check box and click Finish.

3-58

Huawei Technologies Proprietary

Issue 01 (2006-09-20)

OptiX OSN 3500/2500/1500 Configuration Guide

3 Configuring Ethernet Services

----End

Issue 01 (2006-09-20)

Huawei Technologies Proprietary

3-59

View more...

Comments

Copyright ©2017 KUPDF Inc.
SUPPORT KUPDF