01-03 Configuring Ethernet Services
Short Description
Download 01-03 Configuring Ethernet Services...
Description
OptiX OSN 3500/2500/1500 Configuration Guide
Contents
Contents 3 Configuring Ethernet Services ................................................................................................3-1 3.1 Configuring the Point-to-Point EPL Service .................................................................................................3-2 3.1.1 Engineering Requirements...................................................................................................................3-2 3.1.2 Engineering Planning...........................................................................................................................3-2 3.1.3 Configuration Process(by Station) .......................................................................................................3-6 3.1.4 Configuration Process (by Trail)........................................................................................................3-15 3.2 Configuring the PORT Shared EPL Service................................................................................................3-18 3.2.1 Engineering Requirements.................................................................................................................3-18 3.2.2 Engineering Planning.........................................................................................................................3-18 3.2.3 Configuration Process(by Station) .....................................................................................................3-21 3.2.4 Configuration Process (by Trail)........................................................................................................3-26 3.3 Configuring the VCTRUNK Shared EPL Service ......................................................................................3-29 3.3.1 Engineering Requirements.................................................................................................................3-29 3.3.2 Engineering Planning.........................................................................................................................3-30 3.3.3 Configuration Process(by Station) .....................................................................................................3-33 3.3.4 Configuration Process (by Trail)........................................................................................................3-38 3.4 Configuring the EPLn Service ....................................................................................................................3-42 3.4.1 Engineering Requirements.................................................................................................................3-42 3.4.2 Engineering Planning.........................................................................................................................3-42 3.4.3 Configuration Process(by Station) .....................................................................................................3-45 3.4.4 Configuration Process (by Trail)........................................................................................................3-54
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
i
OptiX OSN 3500/2500/1500 Configuration Guide
Figures
Figures Figure 3-1 Ethernet service networking and port allocation...............................................................................3-3 Figure 3-2 Board layout of NE1.........................................................................................................................3-3 Figure 3-3 Board layout of NE5.........................................................................................................................3-4 Figure 3-4 Service configuration diagram..........................................................................................................3-4 Figure 3-5 SDH timeslot allocation for Ethernet services..................................................................................3-6 Figure 3-6 Ethernet service networking and port allocation.............................................................................3-19 Figure 3-7 Service configuration diagram........................................................................................................3-19 Figure 3-8 Timeslot allocation diagram............................................................................................................3-21 Figure 3-9 Ethernet service networking and port allocation.............................................................................3-30 Figure 3-10 Board layout of NE2 and NE3......................................................................................................3-31 Figure 3-11 Service configuration diagram ......................................................................................................3-31 Figure 3-12 SDH timeslot allocation for Ethernet services..............................................................................3-32 Figure 3-13 Ethernet service networking and port allocation...........................................................................3-42 Figure 3-14 Board layout of NE2 and NE3......................................................................................................3-43 Figure 3-15 Board layout of NE4.....................................................................................................................3-43 Figure 3-16 Service configuration diagram......................................................................................................3-44 Figure 3-17 SDH timeslot allocation for Ethernet services..............................................................................3-45
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
iii
OptiX OSN 3500/2500/1500 Configuration Guide
Tables
Tables Table 3-1 Mapping between Ethernet boards and Ethernet services ..................................................................3-1 Table 3-2 Service requirement of each station....................................................................................................3-2 Table 3-3 Ethernet service connection table .......................................................................................................3-5 Table 3-4 Process of point-to-point EPL service configuration ..........................................................................3-6 Table 3-5 Process of creating point-to-point EPL service (by trail)..................................................................3-15 Table 3-6 Ethernet service connection table .....................................................................................................3-20 Table 3-7 Process of PORT shared EPL service configuration.........................................................................3-21 Table 3-8 Process of creating PORT-shared EPL service (by trail) ..................................................................3-26 Table 3-9 Ethernet service connection table .....................................................................................................3-32 Table 3-10 Process of VCTRUNK shared EPL service configuration..............................................................3-33 Table 3-11 Process of creating VCTRUNK-shared EPL service (by trail) .......................................................3-39 Table 3-12 Ethernet service connection table ...................................................................................................3-44 Table 3-13 Forwarding filter table ....................................................................................................................3-45 Table 3-14 Process of EPLn service configuration...........................................................................................3-46 Table 3-15 Process of creating EPLn service (by trail).....................................................................................3-54
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
v
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
3
Configuring Ethernet Services
About This Chapter This chapter describes the process of configuring Ethernet private line (EPL) and Ethernet private local area network (EPLn) services on the T2000, and related engineering requirements and engineering information as well. The configuration of Ethernet virtual private line (EVPL) and Ethernet virtual private local area network (EVPLn) will be described with resilient packet ring (RPR) in Chapter 4. Through this example, you can learn how to configure EPL and other similar services. The following table is a mapping table which associates the Ethernet services to the Ethernet boards of the OptiX OSN 3500/2500/1500. Table 3-1 Mapping between Ethernet boards and Ethernet services Ethernet ser vices
EPL
EVPL
EPLn
EVPLn
EFT8
Supported
Not supported
Not supported
Not supported
EFT4
Supported
Not supported
Not supported
Not supported
EGT2
Supported
Not supported
Not supported
Not supported
EFS4
Supported
Supported
Supported
Supported
EFS0
Supported
Supported
Supported
Supported
EGS2
Supported
Supported
Supported
Supported
Board
In this chapter, the OptiX OSN 3500 product is taken as an example. For the OptiX OSN 2500 and the OptiX OSN 1500A/B, service configuration is performed in the same way. The only difference is that the boards of the OptiX OSN 2500 and the OptiX OSN 1500A/B are inserted in different slots.
The following table lists the contents of this chapter.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-1
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Title
Description
3.1 Configuring the Point-to-Point EPL Service
Describes how to configure the point-to-point EPL services on the T2000
3.2 Configuring the PORT Shared EPL Service
Describes how to configure the port shared EPL services on the T2000
3.3 Configuring the VCTRUNK Shared EPL Service
Describes how to configure the VCTRUNK shared EPL services on the T2000
3.4 Configuring the EPLn Service
Describes how to configure the EPLn services on the T2000
3.1 Configuring the Point-to-Point EPL Service 3.1.1 Engineering Requirements The two companies A and B in NE1 need to transmit data services to NE5 through multi-service transport platform (MSTP) equipment. The services of A and B are required to be completely isolated. Both A and B provide 100 Mbit/s Ethernet electrical interfaces. A requires 10 Mbit/s bandwidth, B requires 40 Mbit/s bandwidth, and their interconnected equipment does not support VLAN, as shown in Table 3-2. Table 3-2 Service requirement of each station User
Service requirement
Source station (number of ports occupied)
Sink station (number of ports occupied)
Bandwidth
A
Point-to-point
NE1 (1)
NE5 (1)
10 Mbit/s
B
Point-to-point
NE1 (1)
NE5 (1)
40 Mbit/s
3.1.2 Engineering Planning The engineering design department conducts planning based on the above requirements and the engineering information described in Chapter 1, and outputs the following engineering information: z
Networking Diagram
z
Board Information of Each NE
z
Service Configuration Diagram of Each NE
z
Timeslot Allocation Diagram
Networking Diagram Figure 3-1 shows the Ethernet service networking and port allocation.
3-2
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Figure 3-1 Ethernet service networking and port allocation B
A PORT1
PORT2
T2000 STM-4 two-fiber bidirectional nonprotection chain
NE1 STM-16 two-fiber bidirectional MSP ring
NE2
NE5
NE4 PORT1
PORT2
NE3 A
B
VC-Trunk
Board Information of Each NE Ethernet boards need to be added according to the added service type and traffic volume. NE1 and NE5 are added with one N1EFS4 board respectively. Other NEs remain unchanged. Figure 3-2 and Figure 3-3 show the board layout of NE1 and NE5 respectively. Figure 3-2 Board layout of NE1
S 1 0
FAN
GSCC GSCC
S S S S S S S S 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8
SL16 N1EFS4
GXCSA
SL16
PQ1
PQ1
S S S S S S S S S 1 2 3 4 5 6 7 8 9
PQ1 PQ1
AUX
PIU FAN
GXCSA
FAN
Issue 01 (2006-09-20)
S S S S S S S S S 2 3 3 3 3 3 3 3 3 9 0 1 2 3 4 5 6 7
S 2 8
PIU
D75S D75S D75S D75S D75S D75S
S S S S S S S S S 1 2 2 2 2 2 2 2 2 9 0 1 2 3 4 5 6 7
Huawei Technologies Proprietary
3-3
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Figure 3-3 Board layout of NE5 S 2 8
AUX
C34S
FAN
PL3
GSCC GSCC
S S S S S S S S 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8
S 1 0
N1EFS4
SL4
GXCSA
S S S S S S S S S 1 2 3 4 5 6 7 8 9
FAN
GXCSA
FAN
PQ1
S S S S S S S S S 2 3 3 3 3 3 3 3 3 9 0 1 2 3 4 5 6 7
PIU
PIU
D75S D75S
S S S S S S S S S 1 2 2 2 2 2 2 2 2 9 0 1 2 3 4 5 6 7
Service Configuration Diagram of Each NE Figure 3-4shows the service configuration diagram of NE1 and NE5. Figure 3-4 Service configuration diagram
PORT
A
VCTRUNK
PORT1
PORT1
10M
SDH
VCTRUNK1 VC4-4:VC12-1~VC12-5
B
PORT
VCTRUNK
PORT2
10M
VCTRUNK1 VC4-4:VC12-1~VC12-5
PORT2
40M
A
VCTRUNK2
VCTRUNK2
VC4-1:VC-3-1
VC4-1:VC-3-1
NE1
B
40M
NE5
Only VC4-4 can be used when the N2EFS0 and N1EFS4 boards are bounded with a path at VC-12 level.
Table 3-3 shows the Ethernet service connection table.
3-4
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Table 3-3 Ethernet service connection table Service
A
B
Source NE
NE1
NE1
Source board - port
13-N1EFS4-1
13-N1EFS4-2
Source Timeslot range
VC4-4: VC12-1–VC12-5
VC4-1: VC3-1
Source VCTRUNK
VCTRUNK1
VCTRUNK2
Working mode of source PORT
Auto negotiation
Auto negotiation
TAG flag of source PORT
Access
Access
VLAN ID of source PORT
1
2
Bound bandwidth
5 x VC-12
1 x VC-3
Sink NE
NE5
NE5
Sink board - port
15-N1EFS4-1
15-N1EFS4-2
Sink Timeslot range
VC4-4: VC12-1–VC12-5
VC4-1: VC3-1
Sink VCTRUNK
VCTRUNK1
VCTRUNK2
Working mode of sink PORT
Auto negotiation
Auto negotiation
TAG flag of sink PORT
Access
Access
VLAN ID of sink PORT
1
2
Attribute
Timeslot Allocation Diagram Figure 3-5shows the SDH timeslot allocation.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-5
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Figure 3-5 SDH timeslot allocation for Ethernet services Ring Station NE1 12-SL16-1
Timeslot
NE4 NE3 NE2 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1
NE1 7-SL16-1
VC-12: 1-5 VC4-3
13-EFS4: VC4-4 VC-3: 1
VC4-4
13-EFS4: VC4-1
Chain Station NE4 13-SL4-1
Timeslot
NE5 7-SL4-1
VC-12: 1-5 VC4-3
15-EFS4: VC4-4 VC-3: 1
VC4-4
15-EFS4: VC4-1 Forward Add/Drop
3.1.3 Configuration Process(by Station) Table 3-4 shows the process of configuring the point-to-point EPL service on the T2000. Table 3-4 Process of point-to-point EPL service configuration Procedure
Description
Remarks
1
Creating a board
2
Configuring Ethernet interfaces
3
Configuring bound paths
4
Creating the point-to-point EPL service
5
Configuring committed access rate (CAR)
6
Configuring the cross-connect from Ethernet boards to SDH line boards
Optional
Creating a Board Follow the steps below to create a board. Step 1 In the Main Topology, double click the NE1 icon to open the NE panel. Step 2 Right click slot 13 according to the board layout shown in Figure 3-2, and select N1EFS4 from the shortcut menu. Step 3 Make sure that the N1EFS4 board has been configured in slot 13 and click
3-6
Huawei Technologies Proprietary
.
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Step 4 Repeat steps 1–3 to create the Ethernet board of NE5. Figure 3-3 shows the board layout of NE5. ----End
Configuring NE1 Data See the T2000 online help for the meaning of each parameter during service configuration.
Step 1 Configuring Ethernet interfaces 1.
Right click the NE1 icon in the Main Topology, and select NE Explorer.
2.
Select 13-N1EFS4 from the Object Tree and Configuration > Ethernet Interface . Management > Ethernet Interface from the Function Tree, and then click
3.
Select External Port, and set as follows. Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 and PORT2 to Enabled. Click Apply.
4.
Select the Tag Attribute tab. Set the TAG of the PORT1 and PORT2 to Access. Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths 1.
Select the Bound Path tab from the Internal Port page.
2.
Click Configuration. Then, the Bound Path Configuration dialog box is displayed.
3.
To set bound paths for VCTRUNK1, set as follows in the dialog box.
Issue 01 (2006-09-20)
−
Configurable Ports: VCTRUNK1
−
Level: VC12-xv
−
Direction: Bidirectional
−
Available Resources: VC4-4
−
Select VC12-1 to VC12-5 from the Available Timeslots one by one, and then click .
Huawei Technologies Proprietary
3-7
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
4.
To set a bound path for VCTRUNK2, set as follows in the dialog box. −
Configurable Ports: VCTRUNK2
−
Level: VC3-xv
−
Direction: Bidirectional
−
Available Resources: VC4-1
−
Select VC3-1 from the Available Timeslots, and then click
−
Click OK.
.
Step 3 Creating the point-to-point EPL service
3-8
1.
Select 13-N1EFS4 from the Object Tree and select Configuration > Ethernet Service > Ethernet Line Service from the Function Tree.
2.
Click New, and the Create Ethernet Line Service dialog box is displayed.
3.
According to Figure 3-4, set as follows to create the EPL service for A. −
Service Type: EPL
−
Service Direction: Bidirectional
−
Source Port: PORT1
−
Sink Port: VCTRUNK1
−
Click Apply.
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
4.
3 Configuring Ethernet Services
Repeat 3 to create the EPL service for B. Set as follows in the dialog box. −
Service Type: EPL
−
Service Direction: Bidirectional
−
Source Port: PORT2
−
Sink Port: VCTRUNK2
−
Click OK.
Step 4 Configuring CAR (optional) 1.
Select 13-N1EFS4 from the Object Tree and select Configuration > QoS Management > Flow Management from the Function Tree, and then the CAR tab.
2.
Click New, and the Create CAR dialog box is displayed.
3.
Set as follows in the dialog box.
Issue 01 (2006-09-20)
−
CAR ID: 1
−
Enabled/Disabled: Enabled
−
Committed Information Rate(kbit/s): 10 Mbit/s
−
Committed Burst Size(kbyte): 0
−
Peak Information Rate(kbit/s): 20 Mbit/s
Huawei Technologies Proprietary
3-9
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
4.
−
Maximum Burst Size(kbyte): 0
−
Click Apply.
Repeat 3 to set as follows in the dialog box: −
CAR ID: 2
−
Enabled/Disabled: Enabled
−
Committed Information Rate(kbit/s): 40 Mbit/s
−
Committed Burst Size(kbyte): 0
−
Peak Information Rate(kbit/s): 50 Mbit/s
−
Maximum Burst Size(kbyte): 0
−
Click OK.
5.
Select the Flow tab.
6.
Set as follows in the dialog box for PORT1 and VCTRUNK1.
7.
−
Bound CAR: 1
−
Click Apply.
Repeat 6 to set the bound CAR for port 2 and VCTRUNK2. −
Bound CAR: 2
−
Click Apply.
Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards
3-10
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
1.
Select NE1 from the Object Tree.
2.
Select Configuration > SDH Service Configuration from the Function Tree.
3.
Click Create, and the Create SDH Service dialog box is displayed.
4.
Set as follows in the dialog box.
5.
Issue 01 (2006-09-20)
−
Level: VC12
−
Direction: Bidirectional
−
Source Slot: 13-N1EFS4-1(SDH-1)
−
Source VC4: VC4-4
−
Source Timeslot Range(e.g.1,3-6): 1–5
−
Sink Slot: 7-N2SL16-1(SDH-1)
−
Sink VC4: VC4-3
−
Sink Timeslot Range(e.g.1,3-6): 1–5
−
Activate Immediately: Yes
−
Click Apply.
Repeat 4 to set as follows in the dialog box. −
Level: VC3
−
Direction: Bidirectional
−
Source Slot: 13-N1EFS4-1(SDH-1)
Huawei Technologies Proprietary
3-11
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services −
Source VC4: VC4-1
−
Source Timeslot Range(e.g.1,3-6): 1
−
Sink Slot: 7-N2SL16-1(SDH-1)
−
Sink VC4: VC4-4
−
Sink Timeslot Range(e.g.1,3-6): 1
−
Activate Immediately: Yes
−
Click Apply.
----End
Configuring NE5 Data The data configuration of NE5 is the same as that of NE1, except that some parameters are different.
Step 1 Configuring Ethernet interfaces 1.
Click the NE switching shortcut icon
2.
Select 15-N1EFS4 from the Object Tree and select Configuration > Ethernet Interface Management > Ethernet Interface from the Function Tree. Then, click .
3.
Select External Port, and set as follows.
. Select NE5, and click OK.
−
Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 and PORT2 to Enabled. Click Apply.
−
Select the TAG Attribute tab. Set the TAG of the PORT1 and PORT2 to Access.
−
Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths 1.
Select the Bound Path tab from the Internal Port page.
2.
Click Configuration, and the Bound Path Configuration dialog box is displayed.
3.
To set bound paths for VCTRUNK1, set as follows in the dialog box.
4.
−
Configurable Ports: VCTRUNK1
−
Level: VC12-xv
−
Direction: Bidirectional
−
Available Resources: VC4-4
−
Select VC12-1 to VC12-5 from the Available Timeslots one by one, and then click .
To set a bound path for VCTRUNK2, set as follows in the dialog box. −
Configurable Ports: VCTRUNK2
−
Level: VC3-xv
−
Direction: Bidirectional
−
Available Resources: VC4-1
−
Select VC3-1 from the Available Timeslots, and then click
−
Click OK.
.
Step 3 Creating the point-to-point EPL service
3-12
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
1.
Select Configuration > Ethernet Service > Ethernet Line Service from the Function Tree.
2.
Click New and the Create Ethernet Line Service dialog box is displayed.
3.
According to Figure 3-4 set as follows to create the EPL service for A.
4.
−
Service Type: EPL
−
Service Direction: Bidirectional
−
Source Port: PORT1
−
Sink Port: VCTRUNK1
−
Click Apply.
Repeat 3 to create the EPL service for B. Set as follows in the dialog box. −
Service Type: EPL
−
Service Direction: Bidirectional
−
Source Port: PORT2
−
Sink Port: VCTRUNK2
−
Click OK.
Step 4 Configuring CAR (optional) 1.
Select Configuration > QoS Management > Flow Management from the Function Tree and select the CAR tab.
2.
Click New and the Create CAR dialog box is displayed.
3.
Set as follows in the dialog box.
4.
−
CAR ID: 1
−
Enabled/Disabled: Enabled
−
Committed Information Rate(kbit/s): 10 Mbit/s
−
Committed Burst Size(kbyte): 0
−
Peak Information Rate(kbit/s): 20 Mbit/s
−
Maximum Burst Size(kbyte): 0
−
Click Apply.
Repeat 3 to set as follows in the dialog box. −
CAR ID: 2
−
Enabled/Disabled: Enabled
−
Committed Information Rate(kbit/s): 40 Mbit/s
−
Committed Burst Size(kbyte): 0
−
Peak Information Rate(kbit/s): 50 Mbit/s
−
Maximum Burst Size(kbyte): 0
−
Click OK.
5.
Select the Flow tab.
6.
Set the bound CAR for PORT1 and VCTRUNK1.
7.
Issue 01 (2006-09-20)
−
Bound CAR: 1
−
Click Apply.
Repeat 6 to set the bound CAR for PORT 2 and VCTRUNK2. −
Bound CAR: 2
−
Click Apply.
Huawei Technologies Proprietary
3-13
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards 1.
Select NE5 from the Object Tree.
2.
Select Configuration > SDH Service Configuration from the Function Tree.
3.
Click Create, and the Create SDH Service dialog box is displayed.
4.
Set as follows in the dialog box.
5.
−
Level: VC12
−
Direction: Bidirectional
−
Source Slot: 15-N1EFS4-1(SDH-1)
−
Source VC4: VC4-4
−
Source Timeslot Range(e.g.1,3-6): 1–5
−
Sink Slot: 7-N2SL4-1(SDH-1)
−
Sink VC4: VC4-3
−
Sink Timeslot Range(e.g.1,3-6): 1–5
−
Activate Immediately: Yes
−
Click Apply.
Repeat 4 to set as follows in the dialog box. −
Level: VC3
−
Direction: Bidirectional
−
Source Slot: 15-N1EFS4-1(SDH-1)
−
Source VC4: VC4-1
−
Source Timeslot Range(e.g.1,3-6): 1
−
Sink Slot: 7-N2SL4-1(SDH-1)
−
Sink VC4: VC4-4
−
Sink Timeslot Range(e.g.1,3-6): 1
−
Activate Immediately: Yes
−
Click Apply.
----End
Configuring NE4 Data The Ethernet service of NE4 to be configured is pass-through service. Follow the steps below to configure NE4 data. Step 1 Click the NE switching shortcut icon
. Select NE4, and click OK.
Step 2 Select Configuration > SDH Service Configuration from the Function Tree. Step 3 Click Create, and the Create SDH Service dialog box is displayed. Step 4 Set as follows in the dialog box.
3-14
z
Level: VC12
z
Direction: Bidirectional
z
Source Slot: 12-N2SL16-1(SDH-1)
z
Source VC4: VC4-3
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
z
Source Timeslot Range(e.g.1,3-6): 1–5
z
Sink Slot: 13-N2SL4-1(SDH-1)
z
Sink VC4: VC4-3
z
Sink Timeslot Range(e.g.1,3-6): 1–5
z
Activate Immediately: Yes
z
Click Apply.
Step 5 Repeat 4 to set as follows in the dialog box. z
Level: VC3
z
Direction: Bidirectional
z
Source Slot: 12-N2SL16-1(SDH-1)
z
Source VC4: VC4-4
z
Source Timeslot Range(e.g.1,3-6): 1
z
Sink Slot: 13-N2SL4-1(SDH-1)
z
Sink VC4: VC4-4
z
Sink Timeslot Range(e.g.1,3-6): 1
z
Activate Immediately: Yes
z
Click OK.
----End
3.1.4 Configuration Process (by Trail) Ethernet service can be created by trail or by station. If you purchase the license with trail management function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by station.
Table 3-5 shows the process of creating point-to-point EPL service on the T2000. Table 3-5 Process of creating point-to-point EPL service (by trail) Procedure
Action
Remarks
1
Create a server trail
See section 1.4.10 of chapter 1
2
Create a trunk link
3
Create an EPL trail
Create a Trunk Link Step 1 Select Trail > Trunk Link Creation from the main menu. Step 2 Set Bandwidth to 5 x VC12 in the pop-up interface. Step 3 Click Browse. Select the source NE (NE1), and click OK.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-15
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Step 4 Select the N1EFS4 board, then select VCTRUNK port 1 and select VC4:4-VC12:1–VC4:4-VC12:5 for available timeslot. Click OK.
Step 5 Click Browse. Select the sink NE (NE5). Select the N1EFS4 board, and select N1EFS4, then select VCTRUNK port 1 and VC4:4-VC12:1–VC4:4-VC12:5 for Available Timeslot. Click OK. Step 6 Select the Activate check box, and leave default setting for others.
Step 7 Click Apply to create the trunk link from NE1 to NE5 of user A.
3-16
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Step 8 Repeat 2–7 to create the trunk link from NE1 to NE5 of user B. ----End
Create an EPL Trail Step 1 Select Trail > Ethernet Trail Creation > EPL Creation from the main menu. Step 2 Set source parameters in the pop-up interface. z
Port Usage Strategy: Port
z
Click Browse and select a proper source line port: NE 1-13-N1EFS4-PORT1.
z
Set sink parameters.
z
Port Usage Strategy: Port
z
Click Browse and select a proper sink line port: NE 5-15-N1EFS4-PORT1.
z
Trunk Link Route Strategy: Use Existing Trunk Link.
z
Select Trunk_Link-0001 with bandwidth being 5 x VC12.
z
Click Next.
Step 3 Set port attributes in the pop-up interface.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-17
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services z
z
For PORT1 of NE1: −
TAG: Access
−
Enable port: Enable
Set PORT1 of NE5 similarly.
Step 4 Click Finish. Step 5 Repeat 1–4 to create EPL service of user B similarly.
----End
3.2 Configuring the PORT Shared EPL Service 3.2.1 Engineering Requirements The headquarters of company C is located in NE1, with two branches (M&S Department and Technical Support Department) located in NE5. The headquarters needs to communicate with two branches. The service of the two branches is required to be isolated completely, each occupying 10 Mbit/s bandwidth. The Ethernet switch of company C provides 100 Mbit/s Ethernet electrical interfaces. The Ethernet switch of headquarters supports virtual local area network (VLAN), but the interconnected equipment of the two branches does not.
3.2.2 Engineering Planning The engineering design department conducts planning based on the above requirements and the engineering information described in Chapter 1, and outputs the following engineering information:
3-18
z
Networking Diagram
z
Board Information of Each NE
z
Service Configuration Diagram of Each NE
z
Timeslot Allocation Diagram
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Networking Diagram Figure 3-6shows the Ethernet service networking and port allocation. Figure 3-6 Ethernet service networking and port allocation C (Headquarters) NE1
T2000
PORT3
PORT1
C(1)
PORT2
C(2)
PORT3
A
NE2
B
PORT4
NE4
NE5 PORT1
PORT2
NE3
VC-Trunk
A
B
Board Information of Each NE NE1 and NE5 do not require any new board.
Service Configuration Diagram of Each NE Figure 3-7shows the service configuration diagram of NE1 and NE5. Figure 3-7 Service configuration diagram
PORT
A
VCTRUNK
VCTRUNK
PORT1
PORT1
10M
10M
VCTRUNK1
VCTRUNK1 VC4-4:VC12-1~VC12-5
B
PORT
PORT2
PORT2 VCTRUNK2
40M
VC4-1:VC-3-1
VCTRUNK2
SDH
C
VC4-4:VC12-6~VC12-10
C1
VC4-4:VC12-6~VC12-10
PORT4 VCTRUNK4
VCTRUNK4 VC4-4:VC12-11~VC12-15
10M
VCTRUNK3
VCTRUNK3
B
40M
VC4-1:VC-3-1
PORT3 PORT3
A
VC4-4:VC12-1~VC12-5
NE1
C2
10M
VC4-4:VC12-11~VC12-15
NE5
Table 3-6 shows the Ethernet service connection table.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-19
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Table 3-6 Ethernet service connection table Service
C
Attribute Source NE
NE1
Source board - port
13-N1EFS4-3
Source Timeslot range
VC4-4: VC12-6–VC12-10
VC4-4: VC12-11–VC12-15
Source VCTRUNK
VCTRUNK3
VCTRUNK4
Working mode of source PORT
Auto negotiation
Auto negotiation
TAG flag of source PORT
Tag aware
Tag aware
Source VLAN ID
3
4
Bound bandwidth
5 x VC12
5 x VC12
Sink NE
NE5
Sink board - port
15-N1EFS4-3
15-N1EFS4-4
Sink Timeslot range
VC4-4: VC12-6–VC12-10
VC4-4: VC12-11–VC12-15
Sink VCTRUNK
VCTRUNK3
VCTRUNK4
Working mode of sink PORT
Auto negotiation
Auto negotiation
TAG flag of sink PORT
Access
Access
Sink VLAN ID
3
4
Timeslot Allocation Diagram The SDH timeslot allocation for Ethernet services is shown in Figure 3-8.
3-20
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Figure 3-8 Timeslot allocation diagram Ring Station NE1 12-SL16-1 Timeslot
NE4 NE2 NE3 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1
NE1 7-SL16-1
VC-12: 6-15 VC4-3
13-EFS4: VC4-4
Chain Station NE4 13-SL4-1 Timeslot
NE5 7-SL4-1
VC-12: 6-15 VC4-3
15-EFS4: VC4-4 Forwared Add/Drop
3.2.3 Configuration Process(by Station) Table 3-7 shows the process of configuring the PORT shared Ethernet EPL service on the T2000. Table 3-7 Process of PORT shared EPL service configuration Procedure
Description
Remarks
1
Creating a board
Not required in this section
2
Configuring Ethernet interfaces
3
Configuring bound paths
4
Creating the PORT shared EPL service
5
Configuring CAR
6
Configuring the cross-connect from Ethernet boards to SDH line boards
Optional
The configuration of the PORT shared EPL service is the same as that of the point-to-point EPL service, except that the Ethernet service configuration on NE1 and interface attributes are different.
Configuring NE1 Data Step 1 Configuring Ethernet interfaces 1.
Right click the NE1 icon in the Main Topology, and select NE Explorer.
2.
Select 13-N1EFS4 from the Object Tree and Configuration > Ethernet Interface . Management > Ethernet Interface from the Function Tree. Then, click
3.
Select External Port, and set as follows.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-21
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services −
Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT3 to Enabled. Click Apply.
−
Select the TAG Attribute tab. Set the TAG of the PORT3 to Tag Aware.
−
Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths 1.
Select the Bound Path tab from the Internal Port page.
2.
Click Configuration, and the Bound Path Configuration dialog box is displayed.
3.
To set bound paths for VCTRUNK3, set as follows in the dialog box.
4.
−
Configurable Ports: VCTRUNK3
−
Level: VC12-xv
−
Direction: Bidirectional
−
Available Resources: VC4-4
−
Select VC12-6 to VC12-10 from the Available Timeslots one by one, and then click .
To set bound paths for VCTRUNK4, set as follows in the dialog box. −
Configurable Ports: VCTRUNK4
−
Level: VC12-xv
−
Direction: Bidirectional
−
Available Resources: VC4-4
−
Select VC12-11 to VC12-15 from the Available Timeslots one by one, and then click .
−
Click OK.
Step 3 Creating the PORT shared EPL service 1.
Select Configuration > Ethernet Service > Ethernet Line Service from the Function Tree.
2.
Click New and the Create Ethernet Line Service dialog box is displayed.
3.
According to Figure 3-7, set as follows to create the service from C to C1.
4.
3-22
−
Service Type: EPL
−
Service Direction: Bidirectional
−
Source Port: PORT3
−
Source VLAN: 3
−
Sink Port: VCTRUNK3
−
Sink VLAN: 3
−
Click Apply.
Repeat 3 to create the service from C to C2. Set as follows in the dialog box. −
Service Type: EPL
−
Service Direction: Bidirectional
−
Source Port: PORT3
−
Source VLAN: 4
−
Sink Port: VCTRUNK4
−
Sink VLAN: 4
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide −
3 Configuring Ethernet Services
Click OK.
Step 4 Configuring the cross-connect from Ethernet boards to SDH line boards 1.
Select NE1 from the Object Tree.
2.
Select Configuration > SDH Service Configuration from the Function Tree.
3.
Click Create, and the Create SDH Service dialog box is displayed.
4.
Set as follows in the dialog box. −
Level: VC12
−
Direction: Bidirectional
−
Source Slot: 13-N1EFS4-1(SDH-1)
−
Source VC4: VC4-4
−
Source Timeslot Range(e.g.1,3-6): 6–15
−
Sink Slot: 7-N2SL16-1(SDH-1)
−
Sink VC4: VC4-3
−
Sink Timeslot Range(e.g.1,3-6): 6–15
−
Activate Immediately: Yes
−
Click OK.
----End
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-23
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Configuring NE5 Data The data configuration of NE5 is performed in the similar way, except that some parameters are different.
Step 1 Configuring Ethernet interfaces 1.
Click the NE switching shortcut icon
2.
Select 15-N1EFS4 from the Object Tree and Configuration > Ethernet Interface Management > Ethernet Interface from the Function Tree, and then click .
3.
Select External Port, and set as follows.
. Select NE5, and click OK.
−
Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT3 and PORT4 to Enabled. Click Apply.
−
Select the TAG Attribute tab. Set the TAG of the PORT3 and PORT4 to Access. Set the Default VLAN ID of the PORT3 to 3. Set the Default VLAN ID of the PORT4 to 4.
−
Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths 1.
Select the Bound Path tab from the Internal Port page.
2.
Click Configuration, and the Bound Path Configuration dialog box is displayed.
3.
To set bound paths for VCTRUNK3, set as follows in the dialog box.
4.
−
Configurable Ports: VCTRUNK3
−
Level: VC12-xv
−
Direction: Bidirectional
−
Available Resources: VC4-4
−
Select VC12-6 to VC12-10 from the Available Timeslots one by one, and then click .
To set bound paths for VCTRUNK4, set as follows in the dialog box. −
Configurable Ports: VCTRUNK4
−
Level: VC12-xv
−
Direction: Bidirectional
−
Available Resources: VC4-4
−
Select VC12-11 to VC12-15 from the Available Timeslots one by one, and then click .
−
Click OK.
Step 3 Creating the PORT shared EPL service
3-24
1.
Select Configuration > Ethernet Service > Ethernet Line Service from the Function Tree.
2.
Click New, and the Create Ethernet Line Service dialog box is displayed.
3.
According to Figure 3-7, set as follows to create the service from C1 to C. −
Service Type: EPL
−
Service Direction: Bidirectional
−
Source Port: PORT3
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
4.
3 Configuring Ethernet Services
−
Source VLAN: 3
−
Sink Port: VCTRUNK3
−
Sink VLAN: 3
−
Click Apply.
Repeat 3 to create the service from C2 to C. Set as follows in the dialog box. −
Service Type: EPL
−
Service Direction: Bidirectional
−
Source Port: PORT4
−
Source VLAN: 4
−
Sink Port: VCTRUNK4
−
Sink VLAN: 4
−
Click OK.
Step 4 Configuring the cross-connect from Ethernet boards to SDH line boards 1.
Select NE5 from the Object Tree.
2.
Select Configuration > SDH Service Configuration from the Function Tree.
3.
Click Create, and the Create SDH Service dialog box is displayed.
4.
Set as follows in the dialog box. −
Level: VC12
−
Direction: Bidirectional
−
Source Slot: 15-N1EFS4-1(SDH-1)
−
Source VC4: VC4-4
−
Source Timeslot Range(e.g.1,3-6): 6-15
−
Sink Slot: 7-N2SL4-1(SDH-1)
−
Sink VC4: VC4-3
−
Sink Timeslot Range(e.g.1,3-6): 6-15
−
Activate Immediately: Yes
−
Click OK.
----End
Configuring NE4 Data The Ethernet service of NE4 to be configured is pass-through service. Follow the steps below to configure NE4 data. Step 1 Click the NE switching shortcut icon
. Select NE4, and click OK.
Step 2 Select Configuration > SDH Service Configuration from the Function Tree. Step 3 Click Create, and the Create SDH Service dialog box is displayed. Step 4 Set as follows in the dialog box. z
Level: VC12
z
Direction: Bidirectional
z
Source Slot: 12-N2SL16-1(SDH-1)
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-25
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services z
Source VC4: VC4-3
z
Source Timeslot Range(e.g.1,3-6): 6–15
z
Sink Slot: 13-N2SL4-1(SDH-1)
z
Sink VC4: VC4-3
z
Sink Timeslot Range(e.g.1,3-6): 6–15
z
Activate Immediately: Yes
z
Click OK.
----End
3.2.4 Configuration Process (by Trail) Ethernet service can be created by trail or by station. If you purchase the license with trail management function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by station.
Table 3-8 shows main procedures of creating PORT shared EPL service on the T2000. Table 3-8 Process of creating PORT-shared EPL service (by trail) Procedure
Description
Remarks
1
Creating a server trail
See section 1.4.10 of Chapter 1
2
Creating a trunk link
3
Creating an EPL trail
Creating a Trunk Link Follow the steps below to create a trunk link. Step 1 Select Trail > Trunk Link Creation from the main menu. Step 2 Set Bandwidth to 5 x VC12 in the interface displayed. Step 3 Click Browse. Select the source NE (NE1). Step 4 In the pop-up interface, select the N1EFS4 board, then select VCTRUNK port 3 and select VC4:4-VC12:6–VC4:4-VC12:10 for available timeslot. Click OK. Step 5 Click Browse. Select the sink NE (NE5). In the pop-up interface, select N1EFS4, VCTRUNK port 3 and VC4:4-VC12:6–VC4:4-VC12:10 for available timeslot. Step 6 Select the Activate check box, and leave the default setting for others.
3-26
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Step 7 Click Apply to create the trunk link from C of NE1 to C1 of NE5. Step 8 Repeat steps 2–7 to create the trunk link from C of NE1 to C2 of NE5. ----End
Creating an EPL Trail Follow the steps below to create an EPL trail. Step 1 Select Trail > Ethernet Trail Creation > EPL Creation from the main menu. Step 2 Set source parameters in the pop-up interface. z
Port Usage Strategy: Port+VLAN
z
Click Browse and select a proper source line port: NE1-13-N1EFS4-PORT3.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-27
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services z
VLAN ID: 3
z
Set sink parameters.
z
Port Usage Strategy: Port+VLAN
Step 3 Click Browse and select a proper sink line port: NE5-15-N1EFS4-PORT3 z
VLAN ID: 3.
z
Trunk Link Route Strategy: Use Existing Trunk Links.
z
Select Trunk_Link-0003 with bandwidth being 5 x VC12.
z
Click Next.
Step 4 Set port attributes in the pop-up interface. z
For PORT3 of NE1:
z
TAG: Tag Aware
z
Enable Port: Enable
z
For PORT3 of NE5:
z
TAG: Access
z
Enable Port: Enable
z
Select the Activate check box.
z
Click Finish.
Step 5 Repeat steps 1–4 to create an EPL trail from C of NE1 to C2 of NE5.
3-28
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
----End
3.3 Configuring the VCTRUNK Shared EPL Service 3.3.1 Engineering Requirements D and D' are users of integrated intelligent communities and located in NE2 and NE3 respectively. They need to communicate with each other. E and E' are users of large corporations and located in NE2 and NE3 respectively. They also need to communicate with each other. Services of communities and that of corporations are isolated completely. Because the traffic peak of community services is at night and that of corporation services is in daytime, they can share a 300 Mbit/s bandwidth. Their Ethernet equipment provides GE optical interfaces but does not support VLAN.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-29
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
3.3.2 Engineering Planning The engineering design department conducts planning based on the above requirements and the engineering information described in Chapter 1, and outputs the following engineering information. z
Networking Diagram
z
Board Information of Each NE
z
Service Configuration Diagram of Each NE
z
Timeslot Allocation Diagram
Networking Diagram Figure 3-9 shows the Ethernet service networking and port allocation. Figure 3-9 Ethernet service networking and port allocation
NE1 T2000
D
PORT1
NE2
E
B
NE4 NE5
PORT2
NE3 PORT1
D’
PORT2
VC-Trunk
E’
Board Information of Each NE Ethernet boards need to be added according to the added service type and traffic volume. NE2 and NE3 are added with one N2EGS2 board respectively. Other NEs remain unchanged. Figure 3-10 shows the board layout of NE2 and NE3.
3-30
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Figure 3-10 Board layout of NE2 and NE3
AUX
FAN S 1 0
FAN
GSCC GSCC
S S S S S S S S 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8 SL16 N2EGS2
SL16
GXCSA
S S S S S S S S S 1 2 3 4 5 6 7 8 9
GXCSA
FAN
PQ1
S S S S S S S S S 2 3 3 3 3 3 3 3 3 9 0 1 2 3 4 5 6 7
PIU
S 2 8
PIU
D75S D75S
S S S S S S S S S 1 2 2 2 2 2 2 2 2 9 0 1 2 3 4 5 6 7
Service Configuration Diagram of Each NE Figure 3-11shows the service configuration of NE2 and NE3. Figure 3-11 Service configuration diagram MAC
D E
VCTRUNK
VCTRUNK
PORT1
MAC PORT1
D’
300M
300M
PORT2
VCTRUNK1
300M
VC4-1:VC3-1~VC3-3 VC4-2:VC3-1~VC3-3
PORT2
VCTRUNK1
SDH
VC4-1:VC3-1~VC3-3 VC4-2:VC3-1~VC3-3
NE2
300M
E’
NE3
Table 3-9 shows the Ethernet service connection table.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-31
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Table 3-9 Ethernet service connection table Service
D
E
Attribute Source NE
NE2
Source board - port
13-N2EGS2-1
Source Timeslot range
VC4-1: VC3-1 to VC3-3
13-N2EGS2-2
VC4-2: VC3-1 to VC3-3 Source VCTRUNK
VCTRUNK1
Working mode of source PORT
1000M full duplex
1000M full duplex
TAG flag of source PORT
Access
Access
VLAN ID of source PORT
1
2
Bound bandwidth
6 x VC-3
Sink NE
NE3
Sink board - port
13-N2EGS2-1
Sink Timeslot range
VC4-1: VC3-1 to VC3-3
13-N2EGS2-2
VC4-2: VC3-1 to VC3-3 Sink VCTRUNK
VCTRUNK1
Working mode of sink PORT
1000M full duplex
1000M full duplex
TAG flag of sink PORT
Access
Access
VLAN ID of sink PORT
1
2
Timeslot Allocation Diagram Figure 3-12 shows the SDH timeslot allocation. Figure 3-12 SDH timeslot allocation for Ethernet services Ring Station NE1 12-SL16-1
Timeslot
NE4 NE3 NE2 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1
NE1 7-SL16-1
VC-3: 1-3
VC4-3
13-EGS2: VC4-1 VC-3: 1-3
VC4-4
13-EGS2: VC4-2 Forward Add/Drop
3-32
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
3.3.3 Configuration Process(by Station) Table 3-10 shows the process of configuring the VCTRUNK shared EPL service on the T2000. Table 3-10 Process of VCTRUNK shared EPL service configuration Procedure
Description
1
Creating a board
2
Configuring Ethernet interfaces
3
Configuring bound paths
4
Creating the VCTRUNK shared EPL service
5
Configuring CAR
6
Configuring the cross-connect from Ethernet boards to SDH line boards
Remarks
Optional.
Creating a Board Follow the steps below to create a board. Step 1 In the Main Topology, double click the NE2 icon to open the NE panel. Step 2 Right click slot 13 according to the board layout of NE1 shown in Figure 3-10, and select N2EGS2. Step 3 Make sure the N2EGS2 board is configured in slot 13, and click
.
Step 4 Repeat steps 1–3 to create the Ethernet board of NE3. Figure 3-10 shows the board layout of NE3. ----End
Configuring NE2 Data See theT2000 online help for the meaning of each parameter during service configuration.
Step 1 Configuring Ethernet interfaces 1.
Right click the NE2 icon in the Main Topology, and select NE Explorer.
2.
Select 13-N2EGS2 from the Object Tree and Configuration > Ethernet Interface . Management > Ethernet Interface from the Function Tree, and then click
3.
Select External Port, and set as follows. Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 and PORT2 to Enabled. Set the Working mode of the PORT1 and PORT2 to 1000M Full-Duplex. Click Apply.
4.
Select the TAG Attribute tab. Set the TAG of the PORT1 and PORT2 to Access. Set the Default VLAN ID of the PORT1 to 1. Set the Default VLAN ID of the PORT2 to 2. Other items adopt the default value. Click Apply.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-33
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Step 2 Configuring bound paths 1.
Select the Bound Path tab from the Internal Port page.
2.
Click Configuration, and the Bound Path Configuration dialog box is displayed.
3.
To set bound paths for VCTRUNK1, set as follows in the dialog box. −
Configurable Ports: VCTRUNK1
−
Level: VC3-xv
−
Direction: Bidirectional
−
Available Resources: VC4-1
−
Select VC3-1 to VC3-3 from the Available Timeslots, and then click
−
Available Resources: VC4-2
−
Select VC3-1 to VC3-3 from the Available Timeslots, and then click
−
Click OK.
. .
Step 3 Creating the VCTRUNK shared EPL service
3-34
1.
Select Configuration > Ethernet Service > Ethernet Line Service from the Function Tree.
2.
Click New, and the Create Ethernet Line Service dialog box is displayed.
3.
According to Figure 3-11, set as follows to create the service of D. −
Service Type: EPL
−
Service Direction: Bidirectional
−
Source Port: PORT1
−
Source VLAN: 1
−
Sink Port: VCTRUNK1
−
Sink VLAN: 1
−
Click Apply.
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
4.
3 Configuring Ethernet Services
Repeat 3 to create the service of E. Set as follows in the dialog box. −
Service Type: EPL
−
Service Direction: Bidirectional
−
Source Port: PORT2
−
Source VLAN: 2
−
Sink Port: VCTRUNK1
−
Sink VLAN: 2
−
Click OK.
Step 4 Configuring the cross-connect from Ethernet boards to SDH line boards 1.
Select NE2 from the Object Tree.
2.
Select Configuration > SDH Service Configuration from the Function Tree.
3.
Click Create, and the Create SDH Service dialog box is displayed.
4.
Set as follows in the dialog box.
Issue 01 (2006-09-20)
−
Level: VC3
−
Direction: Bidirectional
−
Source Slot: 13-N2EGS2-1(SDH-1)
Huawei Technologies Proprietary
3-35
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
5.
−
Source VC4: VC4-1
−
Source Timeslot Range(e.g.1,3-6): 1–3
−
Sink Slot: 12-N2SL16-1(SDH-1)
−
Sink VC4: VC4-3
−
Sink Timeslot Range(e.g.1,3-6): 1–3
−
Activate Immediately: Yes
−
Click Apply.
Repeat 4 to set as follows in the dialog box. −
Level: VC3
−
Direction: Bidirectional
−
Source Slot: 13-N2EGS2-1(SDH-1)
−
Source VC4: VC4-2
−
Source Timeslot Range(e.g.1,3-6): 1–3
−
Sink Slot: 12-N2SL16-1(SDH-1)
−
Sink VC4: VC4-4
−
Sink Timeslot Range(e.g.1,3-6): 1–3
−
Activate Immediately: Yes
−
Click OK.
----End
3-36
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Configuring NE3 Data The data configuration of NE3 is the same as that of NE2.
Step 1 Configuring Ethernet interfaces 1.
Click the NE switching shortcut icon
2.
Select 13-N2EGS2 from the Object Tree and Configuration > Ethernet Interface Management > Ethernet Interface from the Function Tree, and then click .
3.
Select External Port, and set as follows.
. Select NE3, and click OK.
−
Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 and PORT2 to Enabled. Set the Working mode of the PORT1 and PORT2 to 1000M Full-Duplex. Click Apply.
−
Select the TAG Attribute tab. Set the TAG of the PORT1 and PORT2 to Access. Set the Default VLAN ID of the PORT1 to 1. Set the Default VLAN ID of the PORT2 to 2.
−
Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths 1.
Select the Bound Path tab from the Internal Port page.
2.
Click Configuration, and the Bound Path Configuration dialog box is displayed.
3.
To set bound paths for VCTRUNK1, set as follows in the dialog box. −
Configurable Ports: VCTRUNK1
−
Level: VC3-xv
−
Direction: Bidirectional
−
Available Resources: VC4-1
−
Select VC3-1 to VC3-3 from the Available Timeslots, and then click
−
Available Resources: VC4-2
−
Select VC3-1 to VC3-3 from the Available Timeslots, and then click
−
Click OK.
. .
Step 3 Creating the VCTRUNK shared EPL service 1.
Select Configuration > Ethernet Service > Ethernet Line Service from the Function Tree.
2.
Click New, and the Create Ethernet Line Service dialog box is displayed.
3.
According to Figure 3-11, set as follows to create the EPL service for D.
4.
Issue 01 (2006-09-20)
−
Service Type: EPL
−
Service Direction: Bidirectional
−
Source Port: PORT1
−
Source VLAN: 1
−
Sink Port: VCTRUNK1
−
Sink VLAN: 1
−
Click Apply.
Repeat 3 to create the EPL service for E. Set as follows in the dialog box.
Huawei Technologies Proprietary
3-37
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services −
Service Type: EPL
−
Service Direction: Bidirectional
−
Source Port: PORT2
−
Source VLAN: 2
−
Sink Port: VCTRUNK1
−
Sink VLAN: 2
−
Click OK.
Step 4 Configuring the cross-connect from Ethernet boards to SDH line boards 1.
Select NE3 from the Object Tree.
2.
Select Configuration > SDH Service Configuration from the Function Tree.
3.
Click Create, and the Create SDH Service dialog box is displayed.
4.
Set as follows in the dialog box.
5.
−
Level: VC3
−
Direction: Bidirectional
−
Source Slot: 13-N2EGS2-1(SDH-1)
−
Source VC4: VC4-1
−
Source Timeslot Range(e.g.1,3-6): 1–3
−
Sink Slot: 7-N2SL16-1(SDH-1)
−
Sink VC4: VC4-3
−
Sink Timeslot Range(e.g.1,3-6): 1–3
−
Activate Immediately: Yes
−
Click Apply.
Repeat 4 to set as follows in the dialog box. −
Level: VC3
−
Direction: Bidirectional
−
Source Slot: 13-N2EGS2-1(SDH-1)
−
Source VC4: VC4-2
−
Source Timeslot Range(e.g.1,3-6): 1–3
−
Sink Slot: 7-N2SL16-1(SDH-1)
−
Sink VC4: VC4-4
−
Sink Timeslot Range(e.g.1,3-6): 1–3
−
Activate Immediately: Yes
−
Click OK.
----End
3.3.4 Configuration Process (by Trail) Ethernet service can be created by trail or by station. If you purchase the license with trail management function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by station.
Table 3-11 shows the process of creating VCTRUNK shared EPL service on the T2000.
3-38
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Table 3-11 Process of creating VCTRUNK-shared EPL service (by trail) Procedure
Action
Remarks
1
Create a server trail
See section 1.4.10 of chapter 1
2
Create a trunk link
3
Create an EPL trail
Create a Trunk Link Step 1 Select Trail > Trunk Link Creation from the main menu. Step 2 Set Bandwidth to 6 x VC3 in the pop-up interface. Step 3 Click Browse. Select the source NE (NE2). Step 4 In the pop-up interface, select the N2EGS2 board, then select VCTRUNK Port 1, 1 and 2 for Higher Order and VC4:1-VC3:1–VC4:1-VC3:3 and VC4:2-VC3:1–VC4:2-VC3:3 for available timeslot. Click OK.
Step 5 Click Browse. Select the sink NE (NE3). In the pop-up interface, select N2EGS2, VCTRUNK port 1, 1 and 2 for Higher Order, and VC4:1-VC3:1–VC4:1-VC3:3 and VC4:2-VC3:1–VC4:2-VC3:3 for available timeslot. Step 6 Select the Activate check box, and leave the default setting for others.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-39
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Step 7 Click Apply to create the trunk link from NE2 to NE3 shared by users D, D', E, and E'. ----End
Create an EPL Trail Step 1 Select Trail > Ethernet Trail Creation > EPL Creation from the main menu. Step 2 Set source parameters in the pop-up interface. z
Port Usage Strategy: Port+VLAN
z
Click Browse and select a proper source line port: NE2-13-N2EGS2-PORT1.
z
VLAN ID: 1
Step 3 Set sink parameters.
3-40
z
Port Usage Strategy: Port+VLAN
z
Click Browse and select a proper source line port: NE3-13-N2EGS2-PORT1.
z
VLAN ID: 1.
z
Trunk Link Route Strategy: Use Existing Trunk Link.
z
Select the trunk link with bandwidth being 6 x VC3.
z
Click Next.
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Step 4 Set port attributes in the pop-up interface. z
z
z
For PORT1 of NE2: −
TAG: Access
−
Enable Port: Enable
For PORT1 of NE3: −
TAG: Access
−
Enable Port: Enable
Select the Activate check box.
Step 5 Click Finish to create the EPL trail from D of NE2 to D' of NE3. Step 6 Repeat steps 1–5 to create an EPL trail from E of NE2 to E' of NE3. ----End
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-41
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
3.4 Configuring the EPLn Service 3.4.1 Engineering Requirements Company F has three branches located in NE2, NE3 and NE4 respectively. The information needs to be shared between the branches, and any two branches can visit each other. The three branches share a 10 Mbit/s bandwidth dynamically. The Ethernet equipment of company F provides 100 Mbit/s Ethernet interfaces.
3.4.2 Engineering Planning The engineering design department conducts planning based on the above requirements and the engineering information described in Chapter 1, and outputs the following engineering information. z
Networking Diagram
z
Board Information of Each NE
z
Service Configuration Diagram of Each NE
z
Timeslot Allocation Diagram
Networking Diagram Figure 3-13 shows the Ethernet service networking and port allocation. Figure 3-13 Ethernet service networking and port allocation
NE1
T2000
VCTRUNK1
VB PORT1
VB
VCTRUNK1
NE2
PORT1
B
NE4
PORT1
PORT1
NE3 F1
NE5
F3 VCTRUNK
PORT1 VCTRUNK1
F2
VB
VCTRUNK2
PORT1
Board Information of Each NE Ethernet boards need to be added according to the added service type and traffic volume. NE2, NE3 and NE4 are added with one N2EFS0 board respectively. Other NEs remain unchanged. Figure 3-14 and Figure 3-15 show the board layout of NE2 and NE3, and NE4 respectively.
3-42
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Figure 3-14 Board layout of NE2 and NE3
AUX
PIU FAN S 1 0
GSCC GSCC
GXCSA
N2EFS0
S S S S S S S S 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8
GXCSA
S S S S S S S S S 1 2 3 4 5 6 7 8 9
SL16
FAN
SL16 N2EGS2
FAN
PQ1
S S S S S S S S S 2 3 3 3 3 3 3 3 3 9 0 1 2 3 4 5 6 7
ETF8
S 2 8
PIU
D75S D75S
S S S S S S S S S 1 2 2 2 2 2 2 2 2 9 0 1 2 3 4 5 6 7
Figure 3-15 Board layout of NE4
FAN S 1 0
FAN
GSCC GSCC
N2EFS0
SL4 PL3
SL16
S S S S S S S S 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8
GXCSA
GXCSA
SL16
S S S S S S S S S 1 2 3 4 5 6 7 8 9
AUX
ETF8
PIU
FAN
PQ1 PQ1
S S S S S S S S S 2 3 3 3 3 3 3 3 3 9 0 1 2 3 4 5 6 7
C34S
S 2 8
PIU
D75S D75S D75S D75S
S S S S S S S S S 1 2 2 2 2 2 2 2 2 9 0 1 2 3 4 5 6 7
Service Configuration Diagram of Each NE Figure 3-16 shows the service configuration of NE2, NE3 and NE4.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-43
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Figure 3-16 Service configuration diagram PORT
VCTRUNK LP2
PORT
VCTRUNK
LP1 PORT1 10M
VCTRUNK1 VC4-4:VC12-1~VC12-5
F1
VB1
LP2
F2
PORT1 LP1
NE2
VCTRUNK1
LP3
10M
VB1
VC4-4:VC12-1~VC12-5
VCTRUNK2
PORT
VCTRUNK
VC4-4:VC12-6~VC12-10
NE3
LP2
LP1 PORT1
SDH
F3
10M
VCTRUNK1 VC4-4:VC12-1~VC12-5
VB1 NE4
Table 3-12shows the Ethernet service connection table. Table 3-12 Ethernet service connection table Service
F
Attribute
3-44
Source NE
NE3
Source board - port
14-N2EFS0-1
Source Timeslot range
VC4-4: VC12-1–VC12-5
VC4-4: VC12-6–VC12-10
Source VCTRUNK
VCTRUNK1
VCTRUNK2
Source VCTRUNK attribute
PE
PE
Working mode of source PORT
Auto negotiation
TAG flag of source PORT
Access
VLAN ID of source PORT
11 (Set as the user's demand)
VB
VB1
Attached port
PORT1, VCTRUNK1, VCTRUNK2
Sink NE
NE2
NE4
Sink board - port
14-N2EFS0-1
15-N2EFS0-1
Sink Timeslot range
VC4-4: VC12-1–VC12-5
VC4-4: VC12-1–VC12-5
Sink VCTRUNK
VCTRUNK1
VCTRUNK1
Sink VCTRUNK attribute
PE
PE
Working mode of sink PORT
Auto negotiation
Auto negotiation
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Service
F
Attribute TAG flag of sink PORT
Access
Access
VLAN ID of sink PORT
11
11
Virtual bridge (VB)
VB1
VB1
Attached port
PORT1, VCTRUNK1
PORT1, VCTRUNK1
Table 3-13 shows the forwarding filter table of NE2, NE3 and NE4. Table 3-13 Forwarding filter table NE name
VB
VLAN ID
Forwarding port
NE2
VB1
11
PORT1, VCTRUNK1
NE3
VB1
11
PORT1, VCTRUNK1, VCTRUNK2
NE4
VB1
11
PORT1, VCTRUNK1
Timeslot Allocation Diagram Figure 3-17 shows the SDH timeslot allocation. Figure 3-17 SDH timeslot allocation for Ethernet services Ring Station NE1 12-SL16-1 Timeslot
NE4 NE2 NE3 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 VC-12: 1-5
VC4-5
14-EFS0: VC4-4
NE1 7-SL16-1
VC-12: 1-5 15-EFS0: VC4-4
Forward Add/Drop
3.4.3 Configuration Process(by Station) Table 3-14 shows the process of configuring the EPLn service on the T2000.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-45
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Table 3-14 Process of EPLn service configuration Procedure
Description
1
Creating a board
2
Configuring Ethernet interfaces
3
Configuring bound paths
4
Creating the EPLn service
5
Configuring the VLAN forwarding filter table
6
Configuring CAR
7
Configuring the cross-connect from Ethernet boards to SDH line boards
Remarks
Optional, see 3.1.3
Creating a Board Step 1 In the Main Topology, double click the NE2 icon to open the NE panel. Step 2 Right click slot 14 according to Figure 3-14, and then select N2EFS0. Right click slot 31, and then select ETF8. Step 3 Make sure the N2EFS0 and ETF8 boards are configured in slots 14 and 31, and then click Close. Step 4 Repeat steps 1–3 to create the Ethernet board for NE3 and NE4. Figure 3-14 and Figure 3-15 show the board layout of NE3 and NE4 respectively. ----End
Configuring NE2 Data See the NM online help for the meaning of each parameter during service configuration.
Step 1 Configuring Ethernet interfaces 1.
Right click the NE2 icon in the Main Topology, and select NE Explorer.
2.
Select 14-N2EFS0 from the Object Tree and Configuration > Ethernet Interface . Management > Ethernet Interface from the Function Tree, and then click
3.
Select External Port, and set as follows. −
Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 to Enabled. Click Apply.
−
Select the TAG Attribute tab. Set the TAG of the PORT1 to Access. Set the Default VLAN ID of the PORT1 to 11.
−
Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
3-46
1.
Select the Bound Path tab from the Internal Port page.
2.
Click Configuration, and the Bound Path Configuration dialog box is displayed.
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3.
3 Configuring Ethernet Services
To set bound paths for VCTRUNK1, set as follows in the dialog box. −
Configurable Ports: VCTRUNK1
−
Level: VC12-xv
−
Direction: Bidirectional
−
Available Resources: VC4-4
−
Select VC12-1 to VC12-5 from the Available Timeslots, and then click
−
Click OK.
.
Step 3 Creating the EPLn service 1.
Select Configuration > Ethernet Service > Ethernet LAN Service from the Function Tree.
2.
Click New and the Create Ethernet LAN Service dialog box is displayed.
3.
Set the VB name to VB1.
4.
Click Configure Mounted Port and the VB Mount Port Configuration dialog box is displayed.
5.
Set as follows in the dialog box according to the service configuration diagram of NE2. Select PORT1 and VCTRUNK1 for Available Mounted Ports, and click . Click OK.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-47
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
6.
Click OK in the Create Ethernet LAN Service dialog box.
Step 4 Configuring the VLAN forwarding filter table
3-48
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
1.
Select Configuration > Ethernet Service > Ethernet LAN Service from the Function Tree. Select VLAN tab.
2.
Click New and the Create VLAN dialog box is displayed.
3.
Set as following in the dialog box. −
VB: 1-VB1
−
VLAN ID: 11
−
Selected forwarding ports: PORT1 and VCTRUNK1
−
Click OK.
Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards 1.
Select NE2 from the Object Tree.
2.
Select Configuration > SDH Service Configuration from the Function Tree.
3.
Click Create and the Create SDH Service dialog box is displayed.
4.
Set as follows in the dialog box.
Issue 01 (2006-09-20)
−
Level: VC12
−
Direction: Bidirectional
−
Source Slot: 14-N2EFS0-1(SDH-1)
−
Source VC4: VC4-4
−
Source Timeslot Range(e.g.1,3-6): 1–5
−
Sink Slot: 12-N2SL16-1(SDH-1)
−
Sink VC4: VC4-5
−
Sink Timeslot Range(e.g.1,3-6): 1–5
−
Activate Immediately: Yes
Huawei Technologies Proprietary
3-49
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services −
Click OK.
----End
Configuring NE3 Data The data configuration of NE3 is performed in the same way as that of NE2, except that some parameters are different.
Step 1 Configuring Ethernet interfaces 1.
Click the NE switching shortcut icon
2.
Select 14-N2EFS0 from the Object Tree and Configuration > Ethernet Interface Management > Ethernet Interface from the Function Tree. Then, click .
3.
Select External Port, and set as follows.
. Select NE3, and click OK.
−
Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 to Enabled. Click Apply.
−
Select the TAG Attribute tab. Set the TAG of the PORT1 to Access. Set the Default VLAN ID of the PORT1 to 11.
−
Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths 1.
3-50
Select the Bound Path tab from the Internal Port page.
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
2.
Click Configuration and the Bound Path Configuration dialog box is displayed.
3.
To set bound paths for VCTRUNK1, set as follows in the dialog box. −
Configurable Ports: VCTRUNK1
−
Level: VC12-xv
−
Direction: Bidirectional
−
Available Resources: VC4-4
−
Select VC12-1 to VC12-5 from the Available Timeslots, and then click
−
Configurable Ports: VCTRUNK2
−
Level: VC12-xv
−
Direction: Bidirectional
−
Available Resources: VC4-4
−
Select VC12-6 to VC12-10 from the Available Timeslots, and then click
−
Click OK.
.
.
Step 3 Creating the EPLn service 1.
Select Configuration > Ethernet Service > Ethernet LAN Service from the Function Tree.
2.
Click New and the Create Ethernet LAN Service dialog box is displayed.
3.
Set the VB name to VB1.
4.
Click Configure Mounted Port and the VB Mount Port Configuration dialog box is displayed.
5.
Set as follows in the dialog box according to the service configuration diagram of NE2. Select PORT1, VCTRUNK1 and VCTRUNK2 for Available Mounted Ports, and click . Click OK.
6.
Click OK in the Create Ethernet LAN Service dialog box.
Step 4 Configuring the VLAN Forward Filter Table 1.
Select Configuration > Ethernet Service > Ethernet LAN Service from the Function Tree. Select VLAN tab.
2.
Click New and the Create VLAN dialog box is displayed.
3.
Set as following in the dialog box. −
VB: 1-VB1
−
VLAN ID: 11
−
Selected forwarding ports: PORT1, VCTRUNK1 and VCTRUNK2
−
Click OK.
Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards 1.
Select NE3 from the Object Tree.
2.
Select Configuration > SDH Service Configuration from the Function Tree.
3.
Click Create and the Create SDH Service dialog box are displayed.
4.
Set as follows in the dialog box.
Issue 01 (2006-09-20)
−
Level: VC12
−
Direction: Bidirectional
−
Source Slot: 14-N2EFS0-1(SDH-1)
Huawei Technologies Proprietary
3-51
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
5.
−
Source VC4: VC4-4
−
Source Timeslot Range(e.g.1,3-6): 1–5
−
Sink Slot: 7-N2SL16-1(SDH-1)
−
Sink VC4: VC4-5
−
Sink Timeslot Range(e.g.1,3-6): 1–5
−
Activate Immediately: Yes
−
Click Apply.
Repeat 3–4 to set as follows in the dialog box. −
Level: VC12
−
Direction: Bidirectional
−
Source Slot: 14-N2EFS0-1(SDH-1)
−
Source VC4: VC4-4
−
Source Timeslot Range(e.g.1,3-6): 6–10
−
Sink Slot: 12-N2SL16-1(SDH-1)
−
Sink VC4: VC4-5
−
Sink Timeslot Range(e.g.1,3-6): 1–5
−
Activate Immediately: Yes
−
Click OK.
----End
Configuring NE4 Data The data configuration of NE4 is performed in the same way as that of NE2.
Step 1 Configuring Ethernet interfaces 1.
Click the NE switching shortcut icon
2.
Select 15-N2EFS0 from the Object Tree and Configuration > Ethernet Interface Management > Ethernet Interface from the Function Tree, and then click .
3.
Select External Port, and set as follows.
. Select NE4, and click OK.
−
Select the Basic Attributes tab. Set the Enabled/Disabled of the PORT1 to Enabled. Click Apply.
−
Select the TAG Attribute tab. Set the TAG of the PORT1 to Access. Set the Default VLAN ID of the PORT1 to 11.
−
Other items adopt the default value. Click Apply.
Step 2 Configuring bound paths
3-52
1.
Select the Bound Path tab from the Internal Port page.
2.
Click Configuration and the Bound Path Configuration dialog box are displayed.
3.
To set bound paths for VCTRUNK1, set as follows in the dialog box. −
Configurable Ports: VCTRUNK1
−
Level: VC12-xv
−
Direction: Bidirectional
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
−
Available Resources: VC4-4
−
Select VC12-1 to VC12-5 from the Available Timeslots, and then click
−
Click OK.
.
Step 3 Creating the EPLn service 1.
Select Configuration > Ethernet Service > Ethernet LAN Service from the Function Tree.
2.
Click New and the Create Ethernet LAN Service dialog box is displayed.
3.
Set the VB name to VB1.
4.
Click Configure Mounted Port and the VB Mount Port Configuration dialog box is displayed.
5.
Set as follows in the dialog box according to the service configuration diagram of NE2. Select PORT1 and VCTRUNK1 for Available Mounted Ports, and click . Click OK.
6.
Click OK in the Create Ethernet LAN Service dialog box.
Step 4 Configuring the VLAN forwarding filter table 1.
Select Configuration > Ethernet Service > Ethernet LAN Service from the Function Tree. Select VLAN tab.
2.
Click New and the Create VLAN dialog box is displayed.
3.
Set as following in the dialog box. −
VB: 1-VB1
−
VLAN ID: 11
−
Selected forwarding ports: PORT1 and VCTRUNK1
−
Click OK.
Step 5 Configuring the cross-connect from Ethernet boards to SDH line boards 1.
Select NE4 from the Object Tree.
2.
Select Configuration > SDH Service Configuration from the Function Tree.
3.
Click Create and the Create SDH Service dialog box is displayed.
4.
Set as follows in the dialog box. −
Level: VC12
−
Direction: Bidirectional
−
Source Slot: 15-N2EFS0-1(SDH-1)
−
Source VC4: VC4-4
−
Source Timeslot Range(e.g.1,3-6): 1–5
−
Sink Slot: 7-N2SL16-1(SDH-1)
−
Sink VC4: VC4-5
−
Sink Timeslot Range(e.g.1,3-6): 1–5
−
Activate Immediately: Yes
−
Click OK.
----End
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-53
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
3.4.4 Configuration Process (by Trail) Ethernet service can be created by trail or by station. If you purchase the license with trail management function, you can create Ethernet service by trail; otherwise, you can only create Ethernet service by station.
Table 3-15 shows the process of creating EPLn service on the T2000. Table 3-15 Process of creating EPLn service (by trail) Procedure
Action
Remarks
1
Create a server trail
See section 1.4.10 of chapter 1
2
Create a trunk link
3
Create an EPLn trail
Create a Trunk Link Step 1 Select Trail > Trunk Link Creation from the main menu. Step 2 Set Bandwidth to 5 x VC12 in the pop-up interface. Step 3 Click Browse. Select the source NE (NE3). Step 4 In the pop-up interface, select the N2EFS0 board, then select VCTRUNK port 1, 4 for Higher Order, VC4:4-VC12:1–VC4:4-VC12:5 for available timeslot. Click OK.
Step 5 Click Browse. Select the sink NE (NE2). In the pop-up interface, select N2EFS0, then select VCTRUNK port 1, 4 for Higher Order, and VC4:4-VC12:1–VC4:4-VC12:5 for available timeslot (lower order). Step 6 Select the Activate check box, and leave the default setting for others.
3-54
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Step 7 Click Apply to create the trunk link from NE3 to NE2. Step 8 Create the trunk link from NE3 to NE4 similarly.
----End
Create an EPLn Trail Step 1 Select Trail > Ethernet Trail Creation > EPLn Creation from the main menu. Step 2 Set source parameters in the pop-up EPLn creation window. Double click the nodes (NE2–NE4) to be added into the EPLn. In the pop-up interface, click available ports and then click OK.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
to select
3-55
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Step 3 Select the trunk link created previously from Trunk Link Route Strategy and click Next.
Step 4 Set port attributes in the port attribute setting window. For PORT1 of NE2, NE3 and NE4:
3-56
z
TAG: Access
z
Port Enable: Enable
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Step 5 Click Add in the VLAN configuration window, and set the following parameter in the VLAN Configuration for Ethernet Trail window. z
VLAN ID: 11
z
Select the PORT and VCTRUNK, click
to select the port, and click OK.
Step 6 Click Next.
Issue 01 (2006-09-20)
Huawei Technologies Proprietary
3-57
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
Step 7 Set the name to be EPLn, select the Activate check box and click Finish.
3-58
Huawei Technologies Proprietary
Issue 01 (2006-09-20)
OptiX OSN 3500/2500/1500 Configuration Guide
3 Configuring Ethernet Services
----End