ISR Step By Step Configuration

November 26, 2018 | Author: Sohaib Omer Salih | Category: Internet Protocols, Ip Address, File Transfer Protocol, Computer Network, Telecommunications
Share Embed Donate


Short Description

Filename: ISR Step By Step Configuration.pdf wifi p2p...

Description

ISR Intralink Management System

Step By Step Configuration Guide

ISR Step By Step Configuration

13/7/2010

Contents A.

GETTING STARTED............................................................................ 3

1.

INSTALL JAVA PLATFORM. PLATFORM. ............................................................ 3

2.

ASSIGN AN IP ADDRESS ADDRESS TO THE PC.............................................. PC.............................................. 3

 B.

GETTING CONNECTED CONNECTED ..................................................................... 5

1.

LOGGING IN ................................................................... ......................................................................................... ...................... 5

C.

CHECKING FUNDAMENTAL HARDWARE OPERATION.......................................................................................... 7

D.

UPGRADING UPGRADING THE ISR FIRMWARE................................................. FIRMWARE................................................. 9

E.

CHANGING CHANGING NETWORK CONFIGURATI CONFIGURATION.................................. ON.................................. 15

F.

LINK CONFIGURATION CONFIGURATION .................................................................... 16

1.

SET DEVISE NAMES .................................................................. ........................................................................... ......... 16

2.

SET THE THE CLOCK.................................................................................. CLOCK.................................................................................. 16

3.

MAKE LINK LINK CONFIGURATI CONFIGURATION ON....................................................... ....................................................... 17

4.

SET ODU TX MUTE CONFIG. (ONLY FOR STANDARD MODE 1+0) ....................................................................... ............................................................................................. ...................... 21

5.

SET PROTECTION CONFIGURATION. (ONLY FOR PROTECTED NON-DIVERSITY NON-DIVERSITY 1+1) ............................................... 22

6.

SET ODU ODU CONFIGURATION CONFIGURATION............................................................. ............................................................. 22

7.

CHECK DATA LINK .................................................................. ............................................................................ .......... 23

G.

REMOTE SYSTEM CONFIGURATION CONFIGURATION ........................................... 23

H.

LINK MONITORING.... MONITORING............................................................................ ........................................................................ 24

1.

STATUS PANEL ........................................................................... .................................................................................... ......... 24

2.

ALARM CONFIGURATION CONFIGURATION ............................................................... 25

3.

ACTIVE ALARMS ...................................................................... ................................................................................ .......... 25

4.

ALARMS THRESHOLDS THRESHOLDS .................................................................... 26

5.

ALARM HISTORY...................................................................... HISTORY................................................................................ .......... 26

I.

UPGRADING UPGRADING THE ODU FIRMWARE .............................................. 27

1.

CHECKING ODU FIRMWARE FIRMWARE .......................................................... 27

2.

DISABLE SPIRAL SEARCH MODE .................................................. 27

3.

FTP TOOL ........................................................................ .............................................................................................. ...................... 28

4.

ODU UPGRADE..................................................................................... UPGRADE..................................................................................... 29

5.

UPDATING TX POWER POWER LEVEL LEVEL........................................................ ........................................................ 31

6.

ENABLE SPIRAL SEARCH MODE ................................................... 32

7.

REPEAT THE STEPS 1-6 FOR THE REMOTE REMOTE STATION............. 32

2

ISR Step By Step Configuration

13/7/2010

Contents A.

GETTING STARTED............................................................................ 3

1.

INSTALL JAVA PLATFORM. PLATFORM. ............................................................ 3

2.

ASSIGN AN IP ADDRESS ADDRESS TO THE PC.............................................. PC.............................................. 3

 B.

GETTING CONNECTED CONNECTED ..................................................................... 5

1.

LOGGING IN ................................................................... ......................................................................................... ...................... 5

C.

CHECKING FUNDAMENTAL HARDWARE OPERATION.......................................................................................... 7

D.

UPGRADING UPGRADING THE ISR FIRMWARE................................................. FIRMWARE................................................. 9

E.

CHANGING CHANGING NETWORK CONFIGURATI CONFIGURATION.................................. ON.................................. 15

F.

LINK CONFIGURATION CONFIGURATION .................................................................... 16

1.

SET DEVISE NAMES .................................................................. ........................................................................... ......... 16

2.

SET THE THE CLOCK.................................................................................. CLOCK.................................................................................. 16

3.

MAKE LINK LINK CONFIGURATI CONFIGURATION ON....................................................... ....................................................... 17

4.

SET ODU TX MUTE CONFIG. (ONLY FOR STANDARD MODE 1+0) ....................................................................... ............................................................................................. ...................... 21

5.

SET PROTECTION CONFIGURATION. (ONLY FOR PROTECTED NON-DIVERSITY NON-DIVERSITY 1+1) ............................................... 22

6.

SET ODU ODU CONFIGURATION CONFIGURATION............................................................. ............................................................. 22

7.

CHECK DATA LINK .................................................................. ............................................................................ .......... 23

G.

REMOTE SYSTEM CONFIGURATION CONFIGURATION ........................................... 23

H.

LINK MONITORING.... MONITORING............................................................................ ........................................................................ 24

1.

STATUS PANEL ........................................................................... .................................................................................... ......... 24

2.

ALARM CONFIGURATION CONFIGURATION ............................................................... 25

3.

ACTIVE ALARMS ...................................................................... ................................................................................ .......... 25

4.

ALARMS THRESHOLDS THRESHOLDS .................................................................... 26

5.

ALARM HISTORY...................................................................... HISTORY................................................................................ .......... 26

I.

UPGRADING UPGRADING THE ODU FIRMWARE .............................................. 27

1.

CHECKING ODU FIRMWARE FIRMWARE .......................................................... 27

2.

DISABLE SPIRAL SEARCH MODE .................................................. 27

3.

FTP TOOL ........................................................................ .............................................................................................. ...................... 28

4.

ODU UPGRADE..................................................................................... UPGRADE..................................................................................... 29

5.

UPDATING TX POWER POWER LEVEL LEVEL........................................................ ........................................................ 31

6.

ENABLE SPIRAL SEARCH MODE ................................................... 32

7.

REPEAT THE STEPS 1-6 FOR THE REMOTE REMOTE STATION............. 32

2

ISR Step By Step Configuration

13/7/2010

A. Getting Started 1.

Install Java Platform.

The ISR does not require a specific management application, instead it uses a browser (e.g Internet Explorer, Firefox). Nevertheless java platform is required in order for the browser to display all aspects (get java platform free at http://www.java.com/ ). ). Connect the PC to the ISR NMS port. •

2.

Assign an IP address to the PC. 1. Select StartConnect ToShow all connections. 2. Right-click the Local Area Connection and select Properties. 3. Select the Internet Protocol (TCP/IP) check box and click Properties.

2. Select TCP/IP

3. Click Properties 1. Click Properties

The manufacturer provides the ISR units with 192.168.0.1 as the default IP addresses. Note: Make sure that the IDU is not connected to the network (if necessary disconnect IF cable). a) Check if it is the default IP. Set: 1. IP Address:192.168.0.254* :192.168.0.254* 2. Subnet Mask:255.255.255.0 3. Default Gateway: Note: * When connected to the Network  use any from (2-254) as long as it is not used as an IDU IP.

Ping the IDR-LC: 1. Select: StartRun ENTER. 2. Type cmd & press ENTER. 3. Type “ping 192.168.0.1” & press ENTER.

3

ISR Step By Step Configuration

13/7/2010

If the IDU does have IP 192.168.0.1 you will get a reply.

b) If there is no reply:

• •

Check connectivity. Change NMS port

c) If it doesn’t seem to be hardware related: • Use Serial Connection to find out the IP (see User Manual). • Use the IP you find to log in. d) If serial cable is not available: • Set ISR to default IP address (see User Manual). • Repeat step a) (Check if it is the default IP) to verify IDU IP address has been set to default.

4

ISR Step By Step Configuration

13/7/2010

B. Getting Connected 1. Logging In  To get connected to the ISR, follow the steps below: 1.

To launch the browser (during this documentation Internet explorer will be used), double-click the application icon on the desktop:

The browser window appears:

2. Type the IP address of the IDU in the Address Bar and press Enter.

Address Bar

3. The Authentication Window will appear. Type User Name Type Password Set to Remember my password • • •

1. Type User Name 2. Type Password

3. Set Remember my password

4. Press OK

5

ISR Step By Step Configuration

13/7/2010

4. The Web Graphical User Interface Screen will appear.

Status Panel 1. Click to view

Menu Navigation Panel

Configuration Panel

Final View

6

ISR Step By Step Configuration

13/7/2010

C. Checking Fundamental Hardware Operation a) Perform an ODU Loop. 1. Select the Intralink ISR AnalysisLoopback Panel to view the ISR loopback capabilities.

2. Select the Local ODU

1. Select Loopback 3. Set Duration to Indefinite 4. Press Start

Note: Make sure that the remote site is not transmitting in the same frequency.

2. Check Status Panel for Loopback operation

1. Check that ODU is Locked 2. Check that Loopback is enabled 3. Check that Tx Power is enabled

4. Check that RSL are green

5. Check that S/N is green (>19)

Note: If status reveal problem (not Green) check the troubleshooting guide.

7

ISR Step By Step Configuration

13/7/2010

b) Disable Loopback Test 1. Select the Intralink ISR AnalysisLoopback Panel to view the ISR loopback capabilities.

2. Select the Local ODU

1. Select Loopback 3. Press Stop

2. Check Status Panel for normal operation

1. Check that ODU is Unlocked

2. Check that transmitter is active 3. Check that Tx Power is enabled

4. Check that RSL is red

5. Check that S/N is N/A

8

ISR Step By Step Configuration

13/7/2010

D. Upgrading the ISR Firmware a) Install iPorter SW tool. 1. Run the executable (.exe) file to install the iPorter SW tool.

Note: The x.x.x will indicate the iPorter SW tool version.

2. Follow the wizard until the installation is complete. b) Store in a familiar location the latest firmware package.

Note: The x.x.x will indicate Application Firmware _ Modem Firmware _ r Package Revision.pkg

c) Check ISR firmware at Intralink ISR Administration Maintenance Reprogramming

Check Application

Check Modem Firmware

9

ISR Step By Step Configuration

13/7/2010

d) Run iPorter 1. To launch the iPorter tool press the windows Start button and select Start  All Programs ISR  iPorter

Click Next

2. Click Browse to find and select the ISR firmware package of files to be used in this upgrade.

2. Select latest firmware package

1. Click Browse 3. Click Next

Note: Make sure that the firmware package versions ( Application & Modem firmware) are newer than the ones loaded on the ISR (downgrade if not).

10

ISR Step By Step Configuration

13/7/2010

3. Create a Summary Report.

1. Select Text Option

2. Click Browse to specify Location & Title of the Re ort

3. Click Next

4. Connect to the ISR

1. Indoor IP Address

2. User Name

3. Password 4. Click Next

Note: User Name & Password will be provided by Intracom Telecomm (same as logging to ISR)

11

ISR Step By Step Configuration

13/7/2010

5. Select SNMP Version

1. Select Version 2

2. Type the Community String

3. Click Next

Note: The Community String will be provided by Intracom Telecomm.

6. iPorter will display the upgrade plan.

1. View Upgrade Plan

2. Click Next

Note: By clicking Next the upgrade procedure will start.

12

ISR Step By Step Configuration

13/7/2010

7. The Status bar will display the update progress.

Note: If, while performing the firmware upgrade, the message "Lost network connection to ISR" appears, click Finish and re-do the firmware upgrade from step 1. The iPorter tool will start upgrading from the file it had stopped when the network  connection loss occurred.

8. Modem Update The iPorter will ask for approval before Modem Upgrade.

Click Continue

Note: If Modem firmware in package is older select “ Skip Next Action” to continue the rest of the upgrade.

9. IDU Reboot

Click OK

13

ISR Step By Step Configuration

13/7/2010

10. Upgrade Finished

Click Finish

Note: If the application (iPorter) is not closed, it retains the last info typed. Thus if  you need to upgrade more IDUs, you can avoid typing most of the fields.

11. Check ISR firmware at Intralink ISR Administration Maintenance Reprogramming 1. Check Firmware

2. Select Firmware that has Bank2 Active

3. Toggle to Bank1

i.Make sure that the firmwares are the latest. ii. Toggle all firmware to Bank 1 (except if different Mode or FPGA used)

14

ISR Step By Step Configuration

13/7/2010

E. Changing Network Configuration 1. Select the Intralink ISR AdministrationNetwork ConfigurationGeneral to view the Network Configuration Parameters.

1. Select General 2. Set IP 3. Set Netmask 4. Set Gateway

5. Press Update

2. Click OK to the popup window to change settings.

3. When new settings are applied connection will be lost.

Status Panel

4. Repeat step B(Getting Connected) using the new IP

15

ISR Step By Step Configuration

13/7/2010

F. Link Configuration 1.

Set Devise Names  Select the Intralink ISR AdministrationDevise InformationDevise Names.

2. Fill in Information

1. Select Device names

3. Press Update

2.

Set the Clock  Select the Intralink ISR AdministrationDevise InformationSet Date & Time.

1. Select Set Date & Time

2. Select European

3. Set Date & Time

4. Press Update

16

ISR Step By Step Configuration 3.

13/7/2010

Make Link Configuration  Select the Intralink ISR Link Configuration Radio Link Link Configuration.

a) Select ODU Operational Mode

2. Select Operation Mode

1. Select Link Configuration

3. Click Next

Make appropriate selection as specified on WO. Standard Mode: Unprotected (1+0) Protected Non-Diversity: Hot Standby (1+1) {Uses only one frequency} Protected Diversity: Frequency Diversity (1+1) {Uses two frequencies} East-West Mode: Repeater Mode (2+0) {One IDU transmitting to two sites} b) Select IDU Operational Mode

1. Select Operation Mode

2. Click Next

Select IDU Mode (Capacity-Channel Size-Modulation) according to WO. Note: For full operation of the selected Mode the appropriate interfaces must be present.

17

ISR Step By Step Configuration

13/7/2010

c) Select ODU Configuration

1. Select Tx Power

Only if link is established

2. Click Next

For Protected Diversity & East-West Mode you need to set the Tx power to each ODU. Note: The range of the available Tx Power values will depend on the current modulation. Thus, if the required value is not present select the nearest one.

d) Select ODU Channel Selection.

1. Select Manual Frequency Entry 2. Type the Frequency

3. Click Next

For Protected Diversity & East-West Mode you need to set the frequency (different value) to each ODU.

18

ISR Step By Step Configuration

13/7/2010

e) Summary of Configuration Check the summary of the configuration that you have set and proceed to update. If incorrect settings have been set, select Redo to repeat Configuration.

1. Verify Configuration

2. Click Update

f) Link Configuration will star.

12. Wait until Successful message appear.

19

ISR Step By Step Configuration

13/7/2010

g) Restart IDU Select the Intralink ISR Administration Maintenance Reboot

2. Select IDU

1. Select Reboot

3. Press Reboot

Note: After the reboot repeat steps B “Getting Connected” to log in.

h) Set ODU Power Select the Intralink ISR Link Configuration Radio Link ODU Power

2. Select Tx Power

1. Select ODU Power

Only if link is established

3. Press Update

Note: This step is required only if power was not set according to WO during step c) “Select ODU Configuration”

20

ISR Step By Step Configuration

13/7/2010

i) Set ODU Channel Select the Intralink ISR Link Configuration Radio Link ODU Channel

2. Select Manual Frequency Entry 3. Type Frequency

1. Select ODU Channel 4. Click Next

For Protected Diversity & East-West Mode you need to set the frequency (different value) to each ODU. Note: This step is required even if frequency was set according to WO during step d) “Select ODU Channel Selection”

4.

Set ODU Tx Mute Config. (Only for Standard Mode 1+0)  Select the Intralink ISR Link Configuration Radio Link ODU Tx Mute Config.

2. Select Output Remains the Same

1. Select ODU Tx Mute Config.

3. Click Update

21

ISR Step By Step Configuration 5.

13/7/2010

Set Protection Configuration. (Only for Protected Non-  Diversity 1+1) 

Select the Intralink ISR Link Configuration Radio Link Protection Configuration Power down ODU after switch: Disabled Preferred ODU: East APS Switch: Enabled Remote Transmitter Switching: Enabled

2. Select Settings

1. Select Protection Configuration

3. Click Update

6.

Set ODU Configuration 

Select the Intralink ISR Link Configuration Radio Link ODU Configuration

3. Select Enable 1. Select ODU Configuration

2. Set SSW to 500 kHz

4. Click Update

22

ISR Step By Step Configuration 7.

13/7/2010

Check Data Link 

a) Select the Intralink ISR Link Configuration Data Link E1/T1 Ports Make sure that the E1 configured are active (dark black letters). Click the E1/T1 link a second time to make sure the window is refreshed.

2. Check if Active

1. Select E1/T1 Port

Active

3. Reselect E1/T1

Not Active

Note: If some E1 are inactive check ISR User Manual for E1/T1 Cannel Map configuration

G. Remote System Configuration Repeat steps A to F for the remote station and then start the alignment procedure. Continue alignment until the specified receiving signal (RSS I) is reached. After the alignment check link correct operation.

23

ISR Step By Step Configuration

13/7/2010

H. Link Monitoring 1.

Status Panel  1. Check if modems are locked

EAST MODEM : Bottom Modem WEST MODEM: Top Modem 2. Check Status of the modems

ACTIVE: Transmitting & Receiving STANDBY: Receiving NA: Not Available ERROR: Available but with problems 3. Check correct Tx Power 4. Check correct RLS (±3)

RSL: Receiving Signal Level 5. Check S/N Level

S/N > 19 (Depends on Modulation)

6. Check correct Frequency

7. Check correct Mode (Capacity) 8. Check correct IP

9. Check correct Local Host

24

ISR Step By Step Configuration 2.

13/7/2010

Alarm Configuration 

Select the Intralink ISR Analysis Alarms Configuration

1. Select Configuration

2. Click Uncheck All Mask

3. Click Update

Note: You can mask unnecessary alarms later on if required. 3.

Active Alarms 

Check if any of the alarms are unjustifiable.

2. Check Alarms 1. Select Active

Note: If unjustifiable alarms exist check troubleshooting in User Manual.

25

ISR Step By Step Configuration 4.

13/7/2010

Alarms Thresholds 

Select the Intralink ISR Analysis Alarms Threshold Unless specified differently in WO, make the following settings:

2. Set Thresholds

1. Select Thresholds

5.

Alarm History 

Select the Intralink ISR Analysis Alarms History

1. Select History

2. Click Clear History

26

ISR Step By Step Configuration

13/7/2010

I. Upgrading the ODU Firmware 1.

Checking ODU Firmware 

Select the IntralinkISR Administration  Maintenance  Reprogramming Check ODU East & West (in case of 1+1) Firmware

1. Select Re ro rammin East Firmware

West Firmware

Note: Make sure that the firmware version is newer than the ones loaded on t he ODU (downgrade if not). 2.

Disable Spiral Search Mode 

1. Select Disabled

2. Click Update

27

ISR Step By Step Configuration

13/7/2010

FTP Tool 

3.

For the upgrade procedure a FTP tool (Filezilla) will be used. DO NOT POWER DOWN THE IDU OR RESET ANY MODULE during the upgrade (even if the connection is lost).

a)

Requirements

Filezilla version (3.2.6.1 and later). You can find a version from http://filezillaproject.org east_odu_fw.s19 is the ODU firmware for EAST ODU west_odu_fw.s19 is the ODU firmware for WEST ODU •

• •

b)

Filezilla Settings



Open the Filezilla FTP Client.



On the menu toolbar, select Edit  Settings.

1. Edit

2. Settings



In the FileZilla Options window click Connection in the navigation tree. 

In the Timeout group-box, type 999 seconds.

28

ISR Step By Step Configuration 

13/7/2010

In the Maximum Number of retries group-box, type 1 to set the number of retries.

Retries

Timeout





In the FileZilla Options window click Transfers in the navigation tree. 

Click File types in the navigation tree.



Select the Binary option button. Click OK to apply settings

Binary

OK

4.

ODU Upgrade  a) Upgrade ODU West Firmware (only in 1+1)

29

ISR Step By Step Configuration

13/7/2010

Using Filezilla, upgrade West ODU firmware with the file provided (west_odu_fw.s19). • •

Open the Filezilla FTP Client. Type the Address of the ISR as well as the Username and Password in the respective boxes and click  Quickconnect.

1. Address Box

2. UserName Box

Local (PC)

3. Password Box

4. Connect Button

Remote (ISR)



In the Local Site (left bottom two panels) browse for the folder where ODU firmware is located. Locate the west_odu_fw.s19 file and drag the file to the Remote Site panel. The file Status Bar will go to some percent below 100 and stop.



You have to wait ~10min even if the bar disappears. In the Management Tree window follow the links:





IntralinkISR Administration  Maintenance  Reprogramming Refresh the reprogramming screen in order to see at West firmware the new version (if not perform a controller reboot and check after if new Firmware has been uploaded successfully). If not, repeat the procedure again with the West ODU firmware.

b) Upgrade ODU East Firmware

At this moment the West ODU is transmitting at both stations. Using Filezilla, upgrade East ODU firmware with the file provided (east_odu_fw.s19). • •

Open the Filezilla FTP Client. Type the Address of the ISR as well as the Username and Password in the respective boxes and click  Quickconnect.

30

ISR Step By Step Configuration

1. Address Box

13/7/2010

2. UserName Box

3. Password Box

4. Connect Button

Remote (ISR)

Local (PC)

In the Local Site (left bottom two panels) browse for the folder where ODU firmware is located. Locate the east_odu_fw.s19 file and drag the file to the Remote Site panel. The file Status Bar will go to some percent below 100 and stop. •

• •

You have to wait ~10min even if the bar disappears. •

In the Management Tree window follow the links:

IntralinkISR Administration  Maintenance  Reprogramming Refresh the reprogramming screen in order to see at East firmware the new version (if not perform a controller reboot and check after if the new Firmware has been uploaded successfully). If not, repeat the procedure again with the East ODU firmware.

5.

Updating Tx Power level 

In the Management Tree window follow the links:  j) IntralinkISR  Link Configuration  Radio Link ODU Power and update Tx power to required level (see h) Set ODU Power ).

31