LINK CONFIGURATION CONFIGURATION .................................................................... 16
1.
SET DEVISE NAMES .................................................................. ........................................................................... ......... 16
2.
SET THE THE CLOCK.................................................................................. CLOCK.................................................................................. 16
3.
MAKE LINK LINK CONFIGURATI CONFIGURATION ON....................................................... ....................................................... 17
4.
SET ODU TX MUTE CONFIG. (ONLY FOR STANDARD MODE 1+0) ....................................................................... ............................................................................................. ...................... 21
5.
SET PROTECTION CONFIGURATION. (ONLY FOR PROTECTED NON-DIVERSITY NON-DIVERSITY 1+1) ............................................... 22
6.
SET ODU ODU CONFIGURATION CONFIGURATION............................................................. ............................................................. 22
7.
CHECK DATA LINK .................................................................. ............................................................................ .......... 23
G.
REMOTE SYSTEM CONFIGURATION CONFIGURATION ........................................... 23
H.
LINK MONITORING.... MONITORING............................................................................ ........................................................................ 24
1.
STATUS PANEL ........................................................................... .................................................................................... ......... 24
UPDATING TX POWER POWER LEVEL LEVEL........................................................ ........................................................ 31
LINK CONFIGURATION CONFIGURATION .................................................................... 16
1.
SET DEVISE NAMES .................................................................. ........................................................................... ......... 16
2.
SET THE THE CLOCK.................................................................................. CLOCK.................................................................................. 16
3.
MAKE LINK LINK CONFIGURATI CONFIGURATION ON....................................................... ....................................................... 17
4.
SET ODU TX MUTE CONFIG. (ONLY FOR STANDARD MODE 1+0) ....................................................................... ............................................................................................. ...................... 21
5.
SET PROTECTION CONFIGURATION. (ONLY FOR PROTECTED NON-DIVERSITY NON-DIVERSITY 1+1) ............................................... 22
6.
SET ODU ODU CONFIGURATION CONFIGURATION............................................................. ............................................................. 22
7.
CHECK DATA LINK .................................................................. ............................................................................ .......... 23
G.
REMOTE SYSTEM CONFIGURATION CONFIGURATION ........................................... 23
H.
LINK MONITORING.... MONITORING............................................................................ ........................................................................ 24
1.
STATUS PANEL ........................................................................... .................................................................................... ......... 24
UPDATING TX POWER POWER LEVEL LEVEL........................................................ ........................................................ 31
REPEAT THE STEPS 1-6 FOR THE REMOTE REMOTE STATION............. 32
2
ISR Step By Step Configuration
13/7/2010
A. Getting Started 1.
Install Java Platform.
The ISR does not require a specific management application, instead it uses a browser (e.g Internet Explorer, Firefox). Nevertheless java platform is required in order for the browser to display all aspects (get java platform free at http://www.java.com/ ). ). Connect the PC to the ISR NMS port. •
2.
Assign an IP address to the PC. 1. Select StartConnect ToShow all connections. 2. Right-click the Local Area Connection and select Properties. 3. Select the Internet Protocol (TCP/IP) check box and click Properties.
2. Select TCP/IP
3. Click Properties 1. Click Properties
The manufacturer provides the ISR units with 192.168.0.1 as the default IP addresses. Note: Make sure that the IDU is not connected to the network (if necessary disconnect IF cable). a) Check if it is the default IP. Set: 1. IP Address:192.168.0.254* :192.168.0.254* 2. Subnet Mask:255.255.255.0 3. Default Gateway: Note: * When connected to the Network use any from (2-254) as long as it is not used as an IDU IP.
Ping the IDR-LC: 1. Select: StartRun ENTER. 2. Type cmd & press ENTER. 3. Type “ping 192.168.0.1” & press ENTER.
3
ISR Step By Step Configuration
13/7/2010
If the IDU does have IP 192.168.0.1 you will get a reply.
b) If there is no reply:
• •
Check connectivity. Change NMS port
c) If it doesn’t seem to be hardware related: • Use Serial Connection to find out the IP (see User Manual). • Use the IP you find to log in. d) If serial cable is not available: • Set ISR to default IP address (see User Manual). • Repeat step a) (Check if it is the default IP) to verify IDU IP address has been set to default.
4
ISR Step By Step Configuration
13/7/2010
B. Getting Connected 1. Logging In To get connected to the ISR, follow the steps below: 1.
To launch the browser (during this documentation Internet explorer will be used), double-click the application icon on the desktop:
The browser window appears:
2. Type the IP address of the IDU in the Address Bar and press Enter.
Address Bar
3. The Authentication Window will appear. Type User Name Type Password Set to Remember my password • • •
1. Type User Name 2. Type Password
3. Set Remember my password
4. Press OK
5
ISR Step By Step Configuration
13/7/2010
4. The Web Graphical User Interface Screen will appear.
Status Panel 1. Click to view
Menu Navigation Panel
Configuration Panel
Final View
6
ISR Step By Step Configuration
13/7/2010
C. Checking Fundamental Hardware Operation a) Perform an ODU Loop. 1. Select the Intralink ISR AnalysisLoopback Panel to view the ISR loopback capabilities.
2. Select the Local ODU
1. Select Loopback 3. Set Duration to Indefinite 4. Press Start
Note: Make sure that the remote site is not transmitting in the same frequency.
2. Check Status Panel for Loopback operation
1. Check that ODU is Locked 2. Check that Loopback is enabled 3. Check that Tx Power is enabled
4. Check that RSL are green
5. Check that S/N is green (>19)
Note: If status reveal problem (not Green) check the troubleshooting guide.
7
ISR Step By Step Configuration
13/7/2010
b) Disable Loopback Test 1. Select the Intralink ISR AnalysisLoopback Panel to view the ISR loopback capabilities.
2. Select the Local ODU
1. Select Loopback 3. Press Stop
2. Check Status Panel for normal operation
1. Check that ODU is Unlocked
2. Check that transmitter is active 3. Check that Tx Power is enabled
4. Check that RSL is red
5. Check that S/N is N/A
8
ISR Step By Step Configuration
13/7/2010
D. Upgrading the ISR Firmware a) Install iPorter SW tool. 1. Run the executable (.exe) file to install the iPorter SW tool.
Note: The x.x.x will indicate the iPorter SW tool version.
2. Follow the wizard until the installation is complete. b) Store in a familiar location the latest firmware package.
Note: The x.x.x will indicate Application Firmware _ Modem Firmware _ r Package Revision.pkg
c) Check ISR firmware at Intralink ISR Administration Maintenance Reprogramming
Check Application
Check Modem Firmware
9
ISR Step By Step Configuration
13/7/2010
d) Run iPorter 1. To launch the iPorter tool press the windows Start button and select Start All Programs ISR iPorter
Click Next
2. Click Browse to find and select the ISR firmware package of files to be used in this upgrade.
2. Select latest firmware package
1. Click Browse 3. Click Next
Note: Make sure that the firmware package versions ( Application & Modem firmware) are newer than the ones loaded on the ISR (downgrade if not).
10
ISR Step By Step Configuration
13/7/2010
3. Create a Summary Report.
1. Select Text Option
2. Click Browse to specify Location & Title of the Re ort
3. Click Next
4. Connect to the ISR
1. Indoor IP Address
2. User Name
3. Password 4. Click Next
Note: User Name & Password will be provided by Intracom Telecomm (same as logging to ISR)
11
ISR Step By Step Configuration
13/7/2010
5. Select SNMP Version
1. Select Version 2
2. Type the Community String
3. Click Next
Note: The Community String will be provided by Intracom Telecomm.
6. iPorter will display the upgrade plan.
1. View Upgrade Plan
2. Click Next
Note: By clicking Next the upgrade procedure will start.
12
ISR Step By Step Configuration
13/7/2010
7. The Status bar will display the update progress.
Note: If, while performing the firmware upgrade, the message "Lost network connection to ISR" appears, click Finish and re-do the firmware upgrade from step 1. The iPorter tool will start upgrading from the file it had stopped when the network connection loss occurred.
8. Modem Update The iPorter will ask for approval before Modem Upgrade.
Click Continue
Note: If Modem firmware in package is older select “ Skip Next Action” to continue the rest of the upgrade.
9. IDU Reboot
Click OK
13
ISR Step By Step Configuration
13/7/2010
10. Upgrade Finished
Click Finish
Note: If the application (iPorter) is not closed, it retains the last info typed. Thus if you need to upgrade more IDUs, you can avoid typing most of the fields.
i.Make sure that the firmwares are the latest. ii. Toggle all firmware to Bank 1 (except if different Mode or FPGA used)
14
ISR Step By Step Configuration
13/7/2010
E. Changing Network Configuration 1. Select the Intralink ISR AdministrationNetwork ConfigurationGeneral to view the Network Configuration Parameters.
1. Select General 2. Set IP 3. Set Netmask 4. Set Gateway
5. Press Update
2. Click OK to the popup window to change settings.
3. When new settings are applied connection will be lost.
Status Panel
4. Repeat step B(Getting Connected) using the new IP
15
ISR Step By Step Configuration
13/7/2010
F. Link Configuration 1.
Set Devise Names Select the Intralink ISR AdministrationDevise InformationDevise Names.
2. Fill in Information
1. Select Device names
3. Press Update
2.
Set the Clock Select the Intralink ISR AdministrationDevise InformationSet Date & Time.
1. Select Set Date & Time
2. Select European
3. Set Date & Time
4. Press Update
16
ISR Step By Step Configuration 3.
13/7/2010
Make Link Configuration Select the Intralink ISR Link Configuration Radio Link Link Configuration.
a) Select ODU Operational Mode
2. Select Operation Mode
1. Select Link Configuration
3. Click Next
Make appropriate selection as specified on WO. Standard Mode: Unprotected (1+0) Protected Non-Diversity: Hot Standby (1+1) {Uses only one frequency} Protected Diversity: Frequency Diversity (1+1) {Uses two frequencies} East-West Mode: Repeater Mode (2+0) {One IDU transmitting to two sites} b) Select IDU Operational Mode
1. Select Operation Mode
2. Click Next
Select IDU Mode (Capacity-Channel Size-Modulation) according to WO. Note: For full operation of the selected Mode the appropriate interfaces must be present.
17
ISR Step By Step Configuration
13/7/2010
c) Select ODU Configuration
1. Select Tx Power
Only if link is established
2. Click Next
For Protected Diversity & East-West Mode you need to set the Tx power to each ODU. Note: The range of the available Tx Power values will depend on the current modulation. Thus, if the required value is not present select the nearest one.
d) Select ODU Channel Selection.
1. Select Manual Frequency Entry 2. Type the Frequency
3. Click Next
For Protected Diversity & East-West Mode you need to set the frequency (different value) to each ODU.
18
ISR Step By Step Configuration
13/7/2010
e) Summary of Configuration Check the summary of the configuration that you have set and proceed to update. If incorrect settings have been set, select Redo to repeat Configuration.
1. Verify Configuration
2. Click Update
f) Link Configuration will star.
12. Wait until Successful message appear.
19
ISR Step By Step Configuration
13/7/2010
g) Restart IDU Select the Intralink ISR Administration Maintenance Reboot
2. Select IDU
1. Select Reboot
3. Press Reboot
Note: After the reboot repeat steps B “Getting Connected” to log in.
h) Set ODU Power Select the Intralink ISR Link Configuration Radio Link ODU Power
2. Select Tx Power
1. Select ODU Power
Only if link is established
3. Press Update
Note: This step is required only if power was not set according to WO during step c) “Select ODU Configuration”
20
ISR Step By Step Configuration
13/7/2010
i) Set ODU Channel Select the Intralink ISR Link Configuration Radio Link ODU Channel
2. Select Manual Frequency Entry 3. Type Frequency
1. Select ODU Channel 4. Click Next
For Protected Diversity & East-West Mode you need to set the frequency (different value) to each ODU. Note: This step is required even if frequency was set according to WO during step d) “Select ODU Channel Selection”
4.
Set ODU Tx Mute Config. (Only for Standard Mode 1+0) Select the Intralink ISR Link Configuration Radio Link ODU Tx Mute Config.
2. Select Output Remains the Same
1. Select ODU Tx Mute Config.
3. Click Update
21
ISR Step By Step Configuration 5.
13/7/2010
Set Protection Configuration. (Only for Protected Non- Diversity 1+1)
Select the Intralink ISR Link Configuration Radio Link Protection Configuration Power down ODU after switch: Disabled Preferred ODU: East APS Switch: Enabled Remote Transmitter Switching: Enabled
2. Select Settings
1. Select Protection Configuration
3. Click Update
6.
Set ODU Configuration
Select the Intralink ISR Link Configuration Radio Link ODU Configuration
3. Select Enable 1. Select ODU Configuration
2. Set SSW to 500 kHz
4. Click Update
22
ISR Step By Step Configuration 7.
13/7/2010
Check Data Link
a) Select the Intralink ISR Link Configuration Data Link E1/T1 Ports Make sure that the E1 configured are active (dark black letters). Click the E1/T1 link a second time to make sure the window is refreshed.
2. Check if Active
1. Select E1/T1 Port
Active
3. Reselect E1/T1
Not Active
Note: If some E1 are inactive check ISR User Manual for E1/T1 Cannel Map configuration
G. Remote System Configuration Repeat steps A to F for the remote station and then start the alignment procedure. Continue alignment until the specified receiving signal (RSS I) is reached. After the alignment check link correct operation.
23
ISR Step By Step Configuration
13/7/2010
H. Link Monitoring 1.
Status Panel 1. Check if modems are locked
EAST MODEM : Bottom Modem WEST MODEM: Top Modem 2. Check Status of the modems
ACTIVE: Transmitting & Receiving STANDBY: Receiving NA: Not Available ERROR: Available but with problems 3. Check correct Tx Power 4. Check correct RLS (±3)
RSL: Receiving Signal Level 5. Check S/N Level
S/N > 19 (Depends on Modulation)
6. Check correct Frequency
7. Check correct Mode (Capacity) 8. Check correct IP
9. Check correct Local Host
24
ISR Step By Step Configuration 2.
13/7/2010
Alarm Configuration
Select the Intralink ISR Analysis Alarms Configuration
1. Select Configuration
2. Click Uncheck All Mask
3. Click Update
Note: You can mask unnecessary alarms later on if required. 3.
Active Alarms
Check if any of the alarms are unjustifiable.
2. Check Alarms 1. Select Active
Note: If unjustifiable alarms exist check troubleshooting in User Manual.
25
ISR Step By Step Configuration 4.
13/7/2010
Alarms Thresholds
Select the Intralink ISR Analysis Alarms Threshold Unless specified differently in WO, make the following settings:
2. Set Thresholds
1. Select Thresholds
5.
Alarm History
Select the Intralink ISR Analysis Alarms History
1. Select History
2. Click Clear History
26
ISR Step By Step Configuration
13/7/2010
I. Upgrading the ODU Firmware 1.
Checking ODU Firmware
Select the IntralinkISR Administration Maintenance Reprogramming Check ODU East & West (in case of 1+1) Firmware
1. Select Re ro rammin East Firmware
West Firmware
Note: Make sure that the firmware version is newer than the ones loaded on t he ODU (downgrade if not). 2.
Disable Spiral Search Mode
1. Select Disabled
2. Click Update
27
ISR Step By Step Configuration
13/7/2010
FTP Tool
3.
For the upgrade procedure a FTP tool (Filezilla) will be used. DO NOT POWER DOWN THE IDU OR RESET ANY MODULE during the upgrade (even if the connection is lost).
a)
Requirements
Filezilla version (3.2.6.1 and later). You can find a version from http://filezillaproject.org east_odu_fw.s19 is the ODU firmware for EAST ODU west_odu_fw.s19 is the ODU firmware for WEST ODU •
• •
b)
Filezilla Settings
•
Open the Filezilla FTP Client.
•
On the menu toolbar, select Edit Settings.
1. Edit
2. Settings
•
In the FileZilla Options window click Connection in the navigation tree.
In the Timeout group-box, type 999 seconds.
28
ISR Step By Step Configuration
13/7/2010
In the Maximum Number of retries group-box, type 1 to set the number of retries.
Retries
Timeout
•
•
In the FileZilla Options window click Transfers in the navigation tree.
Click File types in the navigation tree.
Select the Binary option button. Click OK to apply settings
Binary
OK
4.
ODU Upgrade a) Upgrade ODU West Firmware (only in 1+1)
29
ISR Step By Step Configuration
13/7/2010
Using Filezilla, upgrade West ODU firmware with the file provided (west_odu_fw.s19). • •
Open the Filezilla FTP Client. Type the Address of the ISR as well as the Username and Password in the respective boxes and click Quickconnect.
1. Address Box
2. UserName Box
Local (PC)
3. Password Box
4. Connect Button
Remote (ISR)
•
In the Local Site (left bottom two panels) browse for the folder where ODU firmware is located. Locate the west_odu_fw.s19 file and drag the file to the Remote Site panel. The file Status Bar will go to some percent below 100 and stop.
•
You have to wait ~10min even if the bar disappears. In the Management Tree window follow the links:
•
•
IntralinkISR Administration Maintenance Reprogramming Refresh the reprogramming screen in order to see at West firmware the new version (if not perform a controller reboot and check after if new Firmware has been uploaded successfully). If not, repeat the procedure again with the West ODU firmware.
b) Upgrade ODU East Firmware
At this moment the West ODU is transmitting at both stations. Using Filezilla, upgrade East ODU firmware with the file provided (east_odu_fw.s19). • •
Open the Filezilla FTP Client. Type the Address of the ISR as well as the Username and Password in the respective boxes and click Quickconnect.
30
ISR Step By Step Configuration
1. Address Box
13/7/2010
2. UserName Box
3. Password Box
4. Connect Button
Remote (ISR)
Local (PC)
In the Local Site (left bottom two panels) browse for the folder where ODU firmware is located. Locate the east_odu_fw.s19 file and drag the file to the Remote Site panel. The file Status Bar will go to some percent below 100 and stop. •
• •
You have to wait ~10min even if the bar disappears. •
In the Management Tree window follow the links:
IntralinkISR Administration Maintenance Reprogramming Refresh the reprogramming screen in order to see at East firmware the new version (if not perform a controller reboot and check after if the new Firmware has been uploaded successfully). If not, repeat the procedure again with the East ODU firmware.
5.
Updating Tx Power level
In the Management Tree window follow the links: j) IntralinkISR Link Configuration Radio Link ODU Power and update Tx power to required level (see h) Set ODU Power ).
Thank you for interesting in our services. We are a non-profit group that run this website to share documents. We need your help to maintenance this website.