dmc plus

August 20, 2017 | Author: edo7474 | Category: Mains Electricity, Power Supply, Amplifier, Analog To Digital Converter, Input/Output
Share Embed Donate


Short Description

nn...

Description

Elektrical measurement of mechanical quantities

Technical Specifications

Digital Amplifier System

DMCplus

1

Contents Survey of the chapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Notes on safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 A

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 1

B

Survey of documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3 1.1 How to use this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4

DMCplus complete system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1 1

2

System design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3 1.1 Housing types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8 1.1.1 Device front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-10 1.1.2 Device rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-13 1.2 Amplifiers for the DMCplus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-15 1.3 Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-16 1.4 Instruction set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-17 1.5 Synchronisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-18 Components of the system device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-19 2.1 Basic components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-21 2.1.1 Power supply / power pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-21 2.1.2 CP03 Central processing unit . . . . . . . . . . . . . . . . . . . . . . . . . . B-25 2.1.3 SY01 Control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-32 2.2 Amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-37 2.2.1 DV01 DC amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-39 2.2.2 DV10 DC amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-40 Printed on 100% chlorine-free paper. File and slipcase are upgraded by chlorine-free polypropylene foil.

DMCplus Technical specifications

2

2.2.3 DV30 600Hz-CF amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2.4 DV35 600Hz-CF amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3 Function cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.1 PI01 Digital input/output board . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.2 AU01 Analogue output board . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.3 IE01 Interface board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.4 DZ65 Digital counter card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3.5 PC01 PCMCIA-hard disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C

Channel connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1 1 2

D

B-41 B-42 B-43 B-43 B-49 B-50 B-53 B-61

Connection cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3 Types of connection for the DV... amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . C-5 2.1 Types of connection for DV01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-6 2.2 Types of connection for DV10,DV30,DV55 . . . . . . . . . . . . . . . . . . . . . C-12 2.3 Types of connection for DV35 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-19 2.4 Types of connection for DV60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-21 2.5 Types of connection for DZ65 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-27

Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-1 1 2

Comparison of the interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS-232-C, RS-422/485 serial interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1 RS-232-C- and RS-422/485 interfaces . . . . . . . . . . . . . . . . . . . . . . . . . 2.1.1 RS-422/485 bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

DMCplus Technical specifications

D-3 D-5 D-6 D-8

3

3

E

Communication with the DMCplus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-1 1

F

IEEE 488-78 parallel interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-9 3.1 IEEE 488-78 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-10 3.1.1 Data lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-13 3.1.2 Handshake lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-14 3.1.3 Control lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-15 3.2 Controller, talker and listener functions . . . . . . . . . . . . . . . . . . . . . . . . D-16 3.3 Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-17 3.4 Service request (SRQ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-18 3.4.1 Serial poll (SPOLL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-19 3.4.2 Parallel poll (PPOLL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-21 3.5 Interface instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-22 3.6 Interface functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-23

Connecting the computer to the DMCplus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E-3

Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-1 Technical data DMCplus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-2 Technical data Amplifier plug-in units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-3 Technical data Function cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F-6

G

Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G-1

H

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H-1

DMCplus Technical specifications

4

Survey of the chapters Chapter A Introduction General notes on how to use this manual. A documentation survey informs you on the manuals available for the DMCplussystem device. Chapter B DMCplus complete system Provides information on the system design and gives technical background information. In addition, the DMCplus-System components are described. Chapter C Channel connection Introduces you to the types of connection for each amplifier. Chapter D Interfaces Description of the interfaces. Informs on the interfaces installed in the DMCplus and on the essential differences between them.

DMCplus Technical specifications

5

Chapter E Communication with the DMCplus Informs on how to connect the DMCplus to your computer. Chapter F Technical data Provides the technical data for the complete system. Chapter G Glossary In the form of a ”lexicon” the glossary explains the most important technical terms used in this manual. Chapter H Index The index is to function as a guide through the manual.

DMCplus Technical specifications

6

Notes on safety

NP03

Prior to power-up make sure that the mains voltage and current type specified on the type plate match the mains voltage and current type at the site of installation and that the electric circuit used has been fused sufficiently. Prior to power-up:

POWER AC

230V

+6% -10%

115V 1,0A/T 2,0A/T

230V 115V

+6% -10% +6% -10%

50-60Hz

D Nr.: voltage selection-switch

D Check the position of the voltage selection-switch on the DMCplus rear (see figure). D Select the switch position according to the mains voltage applied (factory setup: 230V). D Select and adjust the appropriate mains voltage and connect the device (230V +6%/-10% or 115V+6%/-10%). The mains plug may only be connected to an earthed socket (protection class I and II). Before opening the device it must in any case be switched off. Disconnect the mains plug. Do in no case use the cable to disconnect the mains plug. Do not start the device if power cables have suffered damage. If an amplifier channel has been removed, a blind plate must be used to cover the slot. Plug-in units may only be operated if installed in the appropriate housing. The device complies with the safety requirements of DIN EN 61 010- part 1 (VDE 0411-part 1) protection class I.

*

DMCplus Technical specifications

Other power packs also possible, see page B-21

7

To ensure sufficient EMI-proofness, use the Greenline screening only (see HBM special brochure on the Greenline screening concept, EMI- proof measurement cables, G36.35.0). Appropriate use The DMCplus-system with the connected transducers may be used for measurement and directly related control and regulation tasks, only. Any other use is not appropriate. To ensure safe operation, the transducer may only be used according to the specifications given in this manual. When using the transducer, the legal and safety regulations for the respective application must also be observed. The same applies if accessories are used. General dangers in the case of non-observance of the safety instructions The DMCplus-system complies with the state of the art and is operationally reliable. If the device is used and operated inappropriately by untrained personnel, residual dangers might develop. Any person charged with device installation, operation, maintenance or repair must in any case have read and understood the operating manual and the safety instructions, in particular.

DMCplus Technical specifications

8

Residual dangers The DMCplus- scope of performance and supply covers part of the measuring-technology, only. The plant designer/constructor/operator must in addition design, realise and take responsibility for the measuring-system’s safety such that potential residual dangers are minimized. The respective regulations must in any case be observed. Residual dangers regarding the measuring system must be specified explicitly. After password-protected setups and operations have been carried through, make sure that potentially connected controls remain in a safe state until the DMCplus-system switching behaviour has been checked. In this manual, the below symbols are used to refer to residual dangers:

Symbol: Meaning: Danger for people This symbol is used to indicate that, if the safety instructions are not observed, people might suffer grievous bodily harm or death.

Symbol: Meaning: Danger for property This symbol is used to indicate that, if the safety instructions are not observed, property might suffer damage (destruction of plant components).

DMCplus Technical specifications

9

Symbol: Meaning: Note This symbol is used to refer to useful additional information given in the respective section. Symbol: CE Meaning: CE-mark The CE-mark is a guarantee by the manufacturer that his product meets the requirements of the relevant EG Directives (see declaration of conformity at the end of these operating instructions). Safe operation Do only quit error messages if the reason for the error has been eliminated and there is no more danger. Reconstruction and modifications HBM’s express consent is required for modifications regarding the DMCplus-system construction and safety. HBM does not take responsibility for damage resulting from unauthorized modifications. In particular, repair and soldering works on the boards (replacement of components except for EPROMS) are prohibited. If complete componentry is replaced use original HBM components, only.

DMCplus Technical specifications

10

Qualified personnel Qualified personnel means: personnel familiar with the installation, mounting, start-up and operation of the product, and trained according to their job. The device may be used by qualified personnel, only; the technical data and the special safety regulations must in any case be observed. When using the device, the legal and safety regulations for the respective application must also be observed. The same applies if accessories are used.

DMCplus Technical specifications

A-1

Introduction

A 1

Introduction Survey of documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3 1 .1 How to use this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4

DMCplus Technical specifications

A-2

DMCplus Technical specifications

Introduction

Introduction

1

A-3

Survey of documentation

Survey of documentation The product documentation supplied with the DMCplus Digital amplifier system includes two references: The ”Technical specifications” contain background knowledge on the whole amplifier system The manual”Operation with terminal or computer” explains programming and measuring with the DMCplus via terminal and/or computer Two additional computer programs for the DMCplus are available: DMCLabplus and BEAM-DMCplus. The instructions for the DMCLabplus-program describe how to configure the DMCplus using the program, and explain the types of measurement and representation that are at your disposal. The BEAM-DMCplus manual describes a comprehensive applications software. This file includes the ”Technical specifications” and the manual ”Operation with terminal or computer”.

DMCplus Technical specifications

A-4

Introduction

How to use this manual

1.1 How to use this manual This manual is to introduce you to the DMCplus with all its components. It is intended for both, beginners and the more experienced who already have worked with computers. You have several guidelines at your disposal: D The table of contents on the first pages of the manual gives a first impression. D The chapters are separated by register sheets (flaps). The contents of a chapter is given at its beginning. D The header shows the chapter and subchapter you are currently reading. Example: Interfaces

Comparison of the interfaces

D-3

The footer gives the title of the manual (DMCplusTechnical specifications, DMCplus Operation with terminal or computer etc.) D The page numbers are made up of a capital (according to the chapters) and the page number. Every chapter starts with page 1. D The index contains a register that will comfortably guide you through the manual.

DMCplus Technical specifications

B-1

DMCplus-complete system

B

1

2

DMCplus -complete system

System design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3 1.1 Housing types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8 1.1.1 Device front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-10 1.1.2 Device rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-13 1.2 Amplifiers for the DMCplus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-15 1.3 Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-16 1.4 Instruction set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-17 1.5 Synchronisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-18 Components of the system device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-19 2.1 Basic components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-21 2.1.1 Power supply / power rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-21 2.1.2 CP03 Central processing unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-25 2.1.3 SY01 Control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-32 2.2 Amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-37 2.2.1 DV01 DC-amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-39 2.2.2 DV10, DV30, DV55 DC-and CF-amplifier . . . . . . . . . . . . . . . . . . . . . . . . B-40 2.2.3 DV35 600Hz-CF-amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-41 2.2.4 DV60 Md/n-amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-42 2.3 Function cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-43 2.3.1 PI01 Digital input/output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-43 2.3.2 AU01 Analogue output card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-49 2.3.3 IE01 Interface card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-50 2.3.4 DZ65 Digital counter card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-53 2.3.5 PC01 PCMCIA-hard disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-61 DMCplus Technical specifications

B-2

DMCplus Technical specifications

DMCplus-complete system

DMCplus complete system

1

System design

B-3

System design DMCplus characteristics: The DMCplus is a digital amplifier system with up to 28 channels (2 channels per amplifier plug-in unit) that is 100% computer-controlled. The system design is characterised by its bus structure similar to that of a microprocessor system. All amplifier plug-in units and function boards in the DMCplus are connected to theCP03 Central processing unit in parallel via a data and control bus. The individual device plug-in units can be connected as desired. Free slots are also possible. DMCplus features: D The system is controlled by a microprocessor. It enables up to 28 quantities to be measured simultaneously on all channels and converts the analogue measurements into digital signals. D Digital filtering enables the frequency response for each channel to be optimally adapted to the measurement task. D Measuring rates of up to 9600 measurements per second and per channel make the DMCplus the right solution for the complete range of mechanical measurement problems. D Its high accuracy and a resolution of max. 20 bits also enable the DMCplus to be used for precision measurements. D The integral measurement memory for up to 40.000 measured values (optionally 500.000 measurements) enhances the realtime-capacities of the connected computer. D The device parameters and the measurements are stored and the data is protected against power failure.

DMCplus Technical specifications

System design

DMCplus complete system

B-4

Measure Σ n

A Transducer

Zero Cal.

D Analogue-to-digital conversion

Filtering

Averaging (9600meas./s . . . 75meas./s*)

0

E

T

Zero balance

Sensitivity balance

Taring

GA02

EEPROM .......

Σ n

± Measurement output

.......

n DV . . amplifiers

Measurement formatting

Measurement memory 40.000 measurements (expandable to 500,000)

Averaging (60 . . . 1meas./s)



CP03 Central processing unit µ

DMCplus

µ

µ

D

±

SY01

IE01

PI01

8 8

*

Meas./s: Measurements per second

Fig. B 1:

RS-232-C

Data IN Data OUT

RS-422/485

DZ65

32

A

AU01 4

Synchr.

IEEE 488-78

Data I/O

Schematic diagram of measurement-signal processing in the DMCplus

DMCplus Technical specifications

µ

Impuls

Ua

DMCplus complete system

System design

B-5

Analogue-to-digital conversion HBM has developed a special ADC method based on a dual-channel 16-bit-converter. Contrary to conventional methods, the HBM converter does not restrict the resolution and converts without loss of information over the whole bandwidth even with highly dynamic processes. A prerequisite for the HBM ADC-method are very short internal signal propagation times which could only be achieved by an IC chip, developed by HBM in gate-array technology. The high-resolution digitisation permits an uncritical selection of the amplifier’s input sensitivity and avoids restrictions and overmodulations. The signal transmitted from the transducer is boosted in the amplifier and then digitised in the whole signal range without loss of information. Each amplifier channel has been equipped with such a component. Measurement conditioning If a channel has been zero-balanced and tared before the actual measurement, the zero-balance and tare value will be added to the current measurement, thus producing a conditioned value that is available for output on the interface. To enhance the measurement accuracy, a calibration can be started by an external command thus mathematically compensating all internal deviations. The measurements are accessible to the computer without reprocessing.

DMCplus Technical specifications

B-6

DMCplus complete system

System design

Data transmission rates The amplifiers supply measurements at data rates between 75 and 9600measurements/s. With data transmission rates smaller than 9600measurements/s, measurements are averaged in the gate-array. With even smaller data transmission rates (between 1 and 60measurements/s, the CPU determines an additional average value. Due to this averaging, resolutions of up to 20 bits are obtained. For measurement acquisition, 40 000 measurements (standard) are stored in an intermediate memory and measurements from up to 10 channels are transmitted via the IEEE interface at measuring rates of 9600 measurements per second and stored externally. Therefore, the DMCplus enables a total of almost 100 000 measurements per second to be transmitted.

DMCplus Technical specifications

System design

B-7

Transducer and Signal sources

RS-232 RS-422/485

A

A

S/G

B

B

DV30

DV35

Pt100

S/G

µP

DV10

A

Resistors

CP03

DV01

A B

8 / 16 / 24 / 32

Additional memory

8 bits input 8 bits output

A B

Measurement memory

DV55

Inductive

Torque Frequenz/ Speed

Measurement memory

68 000

Basic components

B DC

Amplifier plug-in units

Thermoc.

DV60

PI01

Function cards

DMCplus complete system

SY01 Synchronisation DMCplus

PCMCIA-Slot with 170MB-hard disk

1...4 Parallel interface

Analogue outputs

AU01 Impulse, Frequenzen, Zeitspannen

Fig. B 2:

IE01

IEEE488

A B

DZ65

DMCplus structure DMCplus Technical specifications

DMCplus complete

B-8

System design

Housing types

1.1 Housing types The DMCplus Digital amplifier system is available in three versions: D The narrowdesktop housing can be equipped with max. 12 amplifier channels (corresponds to 6 slots), D The wider version can be equipped with max. 28 channels (corresponds to 14 slots). D Devices in plug-in rack modules are available for integration in 19” cases.

T1 desktop housing with modules 6 slots: (255 x 171 x 367) w x h x d in mm

*

dimensions without handles

DMCplus Technical specifications

T2 desktop housing with 14 + 1 slots: (458 x 171 x 367)

19” E1 or E2 19” plug-in rack with 6 or 14 + 1 slots: (483 x 132.5 x 320*)

DMCplus complete system

System design

Housing types

B-9

Due to the compact construction in SMD technique, two amplifier channels have been realised per slot in the DMCplus thus enabling each device to be equipped with a large quantity of channels. Designation

Maximum no. of amplifier channels1)

T1 desktop housing

X

DMC91T1

12

DMC91E1

12

DMC91T1B

12

DMC91E1B

12

DMC91T2

28

DMC91E2

28

T2 desktop housing

19” plug-in rack module

110/230V mains operation

Battery operation 11...30V =

X X

X X X

X X

X

X

X

X X

X

1) If function boards are used, 2 amplifier channels each are omitted.

Each free slot is covered with a blank plate. Partially equipped DMCplus can be retrofitted with further plug-in units.

DMCplus Technical specifications

DMCplus complete

B-10

1.1.1 Device front

AC DC

Fig. B 3:

Front view of the 12-channel desktop housing

DMCplus Technical specifications

System design

Device front

DMCplus complete system

System design

Device front

B-11

After power-up, the device performs a lamp test, i.e. all LEDs will light up for a short time (approx.100ms). In operating mode, the LEDs signal the following:

WAITING FOR COMMAND The DMCplus waits for an instruction. BUSY The device is processing an instruction. TRANSFER Requested data is ready for transmission. WAITING FOR TRIGGER The DMCplus is waiting for the trigger event. Status-Signal RDY MEASURE The measurement is running. Status-Signal MSR VALUE OVERFLOW Overflow of the internal buther. or One of the amplifier has an overflow during measurement.

DMCplus Technical specifications

B-12

DMCplus complete

System design

Device front

SYSTEM REQUEST System error. The LED is on until the error has been queried with the SST? instruction. COMMAND ERROR A wrong instruction or wrong parameters have been entered. The LED is on until the error has been queried with the *ESR? or EST? instruction. Additional data output of the RDY, MSR and ERR status signals is possible via the SY01 control unit on the I/O socket.

DMCplus Technical specifications

DMCplus complete system

Device rear

System design

B-13

1.1.2 Device rear DMC91T1 Parallel-I/O

DMC91T1B

* Other power packs also possible, see page B-21 NP 03*

Channel numbers

1

3

5

7

9

11

Channel numbers

2

4

6

8 10

12

Slot numbers

1

2

3

SY01

CP03

DMC91E1

4

5

6

Slot 6: for IE01, DV... or other function board as desired

DMC91T2

Synchronisation, as from the second device

DMC91E2

RS-232-Computer connection RS-422/485-Computer connection

Channel numbers

NP 03* BL01

1

3

27

Channel numbers

2

4

28

No Slot

1

2

3

4

Slot numbers

5

6

7

8

9

10

11 12

13

SY01

CP03

14 15 Slot 15 for IE01 only

Fig. B 4: Rear views of different DMC devices, slot/channel numbers and special features with slot assignment

DMCplus Technical specifications

DMCplus complete

B-14

Device rear

System design

NP04

POWER DC DV 55

AU 01

CHANNEL A

PI 01

DV60 CHANNEL A INPUT MD

IE 01

SY 01

CP 03

PARALLEL I / O

11...30V

RESET Bu12

Bu11 RS-232-C V.24 A

BU1

G C

24V = BATT. FUNCTION ONLY

•BY
View more...

Comments

Copyright ©2017 KUPDF Inc.