Table A - ROAD CLASSIFICATION AND SELECTION OF THE REFERENCE LIGHTING CATEGORY Speed limits

Type Description

km/h

mph

Reference lighting category

130-150

81-93

ME1

130

81

ME1

70-90

44-56

ME3a

50

31

ME3a

110

68

ME3a

A1

Extra-urban Highway

A1

Urban Highway

A2

Highw ay road services

A2

Urban Highway road services

B

Main extra-urban roads

B

Main extra-urban road service roads

70-90

44-56

ME4a

C

Subsidiary extra-urban roads (C1 and C2 types)

70-90

44-56

ME3a

C

Subsidiary extra-urban roads

50

31

ME4b

C

Subsidiary extra-urban roads w ith particular limitations

70-90

44-56

ME3a

D

Urban expressw ay

70

44

ME3a

D

Urban expressw ay

50

31

ME3a

E

Inter-district urban roads

50

31

ME3a

E

District urban roads

50

31

ME3c

F

Extra-urban local roads (F1 and F2 types)

70-90

44-56

ME3c

F

Extra-urban local roads

50

31

ME3a

F

Extra-urban local roads

30

19

ME4b

F

Urban local roads (F1 and F2 types)

50

31

S3

F

Urban local roads: tow n center, ambiental isles, zone 30

30

19

ME4b

F

Urban local roads: other situations

30

19

CE4

F

Urban local roads: pedestrian areas

5

3

CE5/S3

F

Urban local roads: tow n center (main users: pedestrian, other users accepted)

5

3

CE5/S3

F

Inter-zonal local roads

50

31

-

F

Inter-zonal local roads

30

19

-

-

Cycle lane

-

Particular destination roads

not declared 30

S3

19

-

Table B - LIGHTING CATEGORY COMPARATION -

ME1

ME2

ME3

ME4

ME5

ME6

-

-

CE0

CE1

CE2

CE3

CE4

CE5

-

-

-

-

-

-

S1

S2

S3

S4

S5

S6

Tabella C - ADDITIONAL LIGHTING CATEGORY

Reference lighting category

CE0

CE1

CE2

CE3

CE4

CE5

-

-

-

Reference lighting category

-

-

-

S1

S2

S3

S4

S5

S6

Additional lighting category

-

EV3

EV4

EV5

-

-

-

-

-

Table D - INFLUENCE PARAMETERS (IF RELEVANTS) TO CONSIDER FOR REFERENCE LIGHTING CATEGORIES IN TABLE A TO DEFINE THE PROJECT LIGHTING CATEGORY Influence parameter Road type

Traffic flow

A1

View field complexity

Conflict zone

High

A2

Slow speed bump

Attack risk index

None

Normal

-

-

Average Field lighting Pedestrian slope level index

-

Normal

B C D

Maximum

-

None

E F

Normal

Cycle lane

-

-