The affected pages are indicated by the use of the following marks. It is requested that necessary actions must be taken to these pages according to the list below.
Mark
Indication
Action required
fi
Page to be newly added
Add
‡
Page to be replaced
Replace
Page to be deleted
Discard
(
)
Pages having no marks are not revised at this time.
Conditions Calibration Standard • Service standard indicates data using calibration test parts. • Manufacturer standard is data for factory test parts.
Nozzle & Nozzle holder part no. Nozzle holder part no. Nozzle part no. Injection pipe (mm) (O/D 5 I/D 5 length) Test oil Oil temperature (°C) Nozzle opening pressure (MPa{kg/cm2}) Transfer pump pressure (kPa{kg/cm2})
— (093400 – 5690) (093100 – 4240)
Rack position (mm)
Pump speed (rpm)
Service standard (cc/1000st)
13.7
Injection volume
Rack point • Rack positions B to E are the refA erence volume (Basic point) when adjusting the B injection volume. • Marks « are average volumes.
Governor performance
Motor 7.5 kW
( ): Injection pump manufacturer's part number Service standard