diesel generator back pressure calculation template...
Description
Exhaust System Back pressure Calculation Exh.gas flow, m3 /min. Exh.gas temp., °C Pipe diam., inch. Pipe lenght, meter. Number of 45° bends Number of 90° bends Exhaust gas velocity Dissipation losses, exh.outlet
100 200 8 10 1 2
Total pipe exh. back pressure, kPa
6000.00 m³/h 0.75 kg/m³ 203.20 mm 0.81 kPa 0.03 kPa 0.14 kPa 51.39 m/s 0.99 kPa
1.96
DDA - Exhaust Silencer, size inch
20
Silencer back pressure, kPa
0.08
Total exh.system back pressure, kPa For engine model the allowable back pressure is 5kPa.Hence, the total piping of mtr. with --nos. long bend shall work satisfactorily without any change in the performance of engine.